PM 30850 Old Town La Quinta Pavement Replacement PlanUTILITIES
IRRIGATION
WATER
SEWER
ELECTRIC
GAS
TELEPHONE
CABLE T.V.
USA
AVENUE 52
VICINITY MAP
N.T.S.
tioR�
COACHELLA VALLEY WATER DITRICT
COACHELLA VALLEY WATER DITRICT
COACHELLA VALLEY WATER DITRICT
IMPERIAL IRRIGATIN DISTRICT
THE GAS COMPANY
VERIZON
TIME WARNER CABLE
UNDERGROUND SERVICE ALERT
(760) 398-2651
(760) 398-2651
(760) 398-2651
(800) 303-7756
(800) 427-2200
(760) 483-5000
(760) 340-1312 EXT. 281
(800) 227-2600
NOTE TO CONTRACTOR' EXISTING UTILITIES
THE LOCATIONS OF UNDERGROUND UTILITIES SHOWN ON THE PLANS WERE OBTAINED FROM A REVIEW OF AVAILABLE RECORD DMA. WHILE DUE CARE WAS
TAKEN IN PREPARATION OF THIS INFORMATION, MSA CONSULTING, INC. CANNOT AND DOES NOT GUARANTEE THE ACCURACY NOR THE COMPLETENESS OF
THE INFORMATION. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE
THE EXACT LOCATIONS OF ALL EXISTING UTIUTIES BEFORE COMMENCING WORK.
THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH RESULT FROM HIS FAILURE TO LOCATE EXACTLY AND
PRESERVE ANY AND ALL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL POTHOLE PROPOSED CROSSINGS OF EXISTING UTILITIES PRIOR TO
CONSTRUCTION AND SHALL VERIFY THEIR HORIZONTAL AND VERTICAL LOCATIONS. IN THE EVENT, DURING CONSTRUCTION, THAT UNKNOWN UTILITIES OR
UNKNOWN STRUCTURES ARE FOUND AT UNEXPECTED ELEVATIONS OR LOCATIONS, MSA CONSULTING, INC. IS TO BE NOTIFIED OF SUCH CONDITION AT
ONCE. MSA CONSULTING, INC. WILL MAKE REQUIRED DESIGN CHANGES AND THE CONTRACTOR AGREES TO COMPLETE ALL WORK, INCLUDING REPAIRS
REQUIRED, IN AN EXPEDITIOUS MANNER. THE CONTRACTOR FURTHER AGREES TO PURSUE DIUGENTLY THE COMPLETION OF SAID WORK.
ANY DISCREPANCY BETWEEN THE PLANS AND FIELD SHALL BE BROUGHT TO THE ATTENTION OF MSA CONSULTING, INC. THE CONTRACTOR SHALL NOTIFY
MSA CONSULTING, INC. PRIOR TO POTHOLING. IF NECESSARY, MSA CONSULTING, INC. SHALL REVISE THE PLANS. THE CONTRACTOR SHALL BEGIN
CONSTRUCTION AFTER REVISIONS ARE APPROVED.
NOTE TO CONTRACTOR. QUANTITY ESTIMATE
MSA CONSULTING, INC. MAKES NO REPRESENTATION CONCERNING THE ESTIMATED QUANTITIES ON THESE PLANS, EXCEPT THAT ALL SUCH FIGURES,
INCLUDING ALL EARTHWORK QUANTITIES, ARE PRELIMINARY ESTIMATES AND FOR PERMIT PURPOSES ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY
TO PREPARE HIS OWN QUANTITY ESTIMATE FOR CONSTRUCTION OR COST PURPOSES. MSA CONSULTING, INC. SHALL NOT BE RESPONSIBLE FOR ANY
DEVIATIONS BETWEEN ESTIMATED QUANTITIES AND ACTUAL QUANTITIES AT THE TIME OF CONSTRUCTION.
NOTE TO CONTRACTOR' SITE CONDITIONS
CONTRACTOR AGREES TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITION DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT APPLIES CONTINUOUSLY AND IS NOT LIMITED TO NORMAL
WORKING HOURS.
THE CONTRACTOR ALSO AGREES TO DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE MSA CONSULTING, INC., HARMLESS FROM ANY AND ALL
LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF THE OWNER OR MSA CONSULTING, INC.
NOTE TO CONTRACTOR' ACCESSIBILITY DETAILS
THE ACCESSIBILITY DETAILS SHOWN ON THESE PLANS, INCLUDING SLOPE AND DISTANCE, WERE CALCULATED USING THE APPROVED DESIGN GRADES ON
THESE PLANS. ACTUAL FIELD CONDITIONS DURING AND AFTER CONSTRUCTION CAN AND MAY CHANGE THE DESIGN PARAMETERS FOR THE ACCESSIBILITY
DETAILS. THE CONTRACTOR SHALL CONFIRM ALL DESIGN SLOPES AND GRADES AND OBTAIN CITY INSPECTION AND APPROVAL PRIOR TO LAYOUT AND
CONSTRUCTION OF ANY ACCESSIBIUTY FACILITIES ON SITE. PRIOR TO FINAL CONSTRUCTION THE CONTRACTOR SHALL NOTIFY MSA CONSULTING, INC.
IMMEDIATELY REGARDING ANY ANTICIPATED CHANGES TO THE ACCESSIBILITY DETAILS.
IT SHALL ALSO BE NOTED THAT THE ACCESSIBILITY STANDARDS CALLED OUT ON THESE PLANS WERE BASED ON THE LATEST CBC AND CITY CODES AND
SPECIFICATIONS AT THE TIME OF PLAN PREPARATION. THEREFORE, IT SHOULD BE NOTED THAT THESE PLANS ARE SUBJECT TO CHANGE BASED ON THE
CURRENT ACCESSIBIUTY CODES AND SPECIFICATIONS AT TIME OF CONSTRUCTION. THE CONTRACTOR SHALL OBTAIN CITY INSPECTION AND APPROVAL PRIOR
TO LAYOUT AND CONSTRUCTION OF ANY ACCESSIBILITY FACILITIES BASED ON CURRENT CODES AND SPECIFICATIONS AT TIME OF CONSTRUCTION.
NOTE TO CONTRACTOR' DRAINAGE INTEGRITY
THIS GRADING PLAN PROVIDES FOR ON-SITE DRAINAGE IN ACCORDANCE WITH THE FLOWLINES SHOWN. IT IS THE DEVELOPER'S RESPONSIBILITY TO
ENSURE THAT THE SWALES ARE CONSTRUCTED BY THE GRADING CONTRACTOR OR LANDSCAPE CONTRACTOR IN ACCORDANCE WITH THE APPROVED
GRADING PLAN AND THAT THE INTEGRITY OF THE SWALES I5 MAINTAINED. THIS PRECLUDES THE CONSTRUCTION OF BLOCK WALLS, FENCES, OR OTHER
STRUCTURES ACROSS FLOWLINES WITHOUT PROVISIONS FOR APPROPRIATE OPENINGS. MSA CONSULTING, INC. ASSUMES NO RESPONSIBILITY FOR
ALTERATIONS IN THE DRAINAGE SYSTEM CAUSED BY ANY SUCH STRUCTURES OR OTHER GRADING MODIFICATIONS MADE BY THE DEVELOPER, HIS
SUBCONTRACTORS, OR THE PROPERTY OWNER.
ABBREVIATIONS
E) EAST
N NORTH
5 SOUTH
W WEST
NE) NORTHEAST
NW) NORTHWEST
SE) SOUTHEAST
SW) SOUTHWEST
AC ASPHALT CONCRETE
BC BEGINNING OF CURVE
BCR BEGIN CURB RETURN
BOC BACK OF CURB
BS BOTTOM OF STEPS
BSL BUILDIG SETBACK
C# CURVE
C/L CENTERLINE
C&G CURB AND GUTTER
C.B. CATCH BASIN
C.Y. CUBIC YARDS
D DEPTH
DB DRAIN BOX
DWG. DRAWING
DWY DRIVEWAY
EA. EACH
EC END OF CURVE
ECR END CURB RETURN
ELEV ELEVATION
EP EDGE OF PAVEMENT
ESMT EASEMENT
EVC
EX.
FF
FG
FL
FS
GB
GF
HC
HP
HZ
INV
LINE
L.F.
LP
MAX.
MH
MIN.
MOC
MVC
NG
NO.
N.T.S.
0/H
P/L
P.C.C.
PCC
PE
PIG
POC
END OF VERTICAL CURVE
EXISTING
FINISHED FLOOR
FINISHED GRADE
FLOWLINE
FINISHED SURFACE
GRADE BREAK
GARAGE FLOOR
HANDICAP
HIGH POINT
HORIZONTAL
INVERT
L#
UNEAL FEET
LOW POINT
MAXIMUM
MANHOLE
MINIMUM
MID -POINT OF CURVE
MIP -POINT OF VERTICAL CURVE
NATURAL GROUND
NUMBER
NOT TO SCALE
OVERHEAD
PROPERTY LINE
PORTLAND CONCRETE CEMENT
POINT OF COMPOUND CURVE
PAD ELEVATION
POINT OF INTERSECTION/GUTTER
POINT ON CURVE
DIG ALERT
Dig iSafely
DIAL TOLL FREE
1-800-227-2600
AT LEAST TWO DAYS
BEFORE YOU DIG
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
NO.
REVISIONS
PRC
PP
PROP.
PT.
PUE
PVI
PVMT
R/W
RAD.
RED.
SD
S.F.
STA.
STD.
S/W
SWR
TB
TC
TF
TOG
TP
TRW
TW
TYP.
VC
VERT
W
WTR
FL
POINT OF REVERSE CURVE
POWER POLE
PROPOSED
POINT
PUBUC UTILITY EASEMENT
POINT OF VERTICAL INTERSECTION
PAVEMENT
RIGHT OF WAY
RADIUS
REDUCER
STORM DRAIN
SQUARE FEET
STATION
STANDARD
SIDEWALK
SEWER
TOP OF BERM
TOP OF CURB
TOP OF FOOTING
TOP OF GRATE
TOP OF PAVEMENT
TOP OF RETAINING WALL
TOP OF WALL
TYPICAL
VERTICAL CURVE
VERTICAL
WIDTH
WATER
IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE , STATE OF CALIFORNIA
PARCEL MAP NO. 30850
OLD TOWN LA QUINTA PLAZA
PAVEMENT REPLACEMENT PLAN
PORTIONS OF LOTS "B" & "E" OF PM 206/60-62
SECTIONS 6, TOWNSHIP 6 SOUTH, RANGE 7 EAST, S.B.M.
PREPARED FOR'
OTLQ, LLC
78-065 MAIN STREET
LA QUINTA, CA 92253
.,....
MAIN STREET
2
3
NUISANCE WATER DISCLAIMER NOTE"
EXCESSIVE OVER -IRRIGATION OF LANDSCAPING, IF IT PERSISTS, CAN POTENTIALLY RESULT IN
DAMAGE TO OR FAILURE OF DRYWELLS, RETENTION BASINS, HARDSCAPE OR PAVEMENT. THE
DESIGN SHOWN HEREIN IS INTENDED TO COMPLY WITH AGENCY REQUIREMENTS, INDUSTRY
STANDARDS AND LOCAL CONDITIONS BASED UPON INFORMATION AVAILABLE TO THE DESIGN
ENGINEER, ASSUMING RESPONSIBLE MAINTENANCE ON THE PART OF THE PROPERTY OWNER
OR ASSOCIATION. IT IS RECOMMENDED THAT THE DEVELOPER INCORPORATE INTO FUTURE
CC&R'S ENFORCEABLE RESTRICTIONS AGAINST OVER -WATERING BY FUTURE RESIDENTS.
APPROVED
DATE
LEGEND"
OM
445
PROPOSED DECORATIVE PAVERS
PROPOSED CONCRETE
EXISTING HARDSCAPE
TO BE REMOVED
CENTERLINE
RIGHT OF WAY
EASEMENT
BOUNDARY
PROPERTY LINE
PROPOSED BARRIER CURB/AC BERM
EXISTING STORM DRAIN
EXISTING WATER MAIN
EXISTING SEWER MAIN
EXISTING UTILITIES: GAS, TELEPHONE,
679.3 EXISTING SPOT ELEVATIONS
EXISTING CONTOURS
PROPOSED CONTOURS
fa ROM MOM MA* 11411101 MIMI WM IMF
ADA PATH OF TRAVEL
SAWCUT LINE
MSA CONSULTING, INC.
PLANNING ■ C lyn. SNGII+I�DIG • LAND SURVEYING
34200 Hos Hct Dun • RANCHO MIRAGE ■ CA 92270
ye, 'TELEPHONE (760) 320-9811 • FAX (760) 323-7893
0'
40'
TV, ETC.
80'
SCALE 1"=40'
120'
INDEX OF SHEETS
SHEET
DESCRIPTION
1
2
3
TITLE SHEET
DEMOLITION PLAN
PRECISE GRADING PLAN
SITE ADDRESS
78010 MAIN STREET
LA QUINTA, CA 92253
NOTE.
SEPARATE PERMITS FROM THE BUILDING AND
SAFETY DEPARTMENT SHALL BE REQUIRED FOR
ALL WALLS.
SOURCE OF TOPOGRAPHY'
FIELD SURVEY PERFORMED BY MSA CONSULTING
INC. MAY 2017.
BENCH PD 104-70
MARK
ELEV.
47.998
(NGVD29 DATUM)
LOCATION BRASS CAP IN CONCRETE MONUMENT ON SOUTH SIDE
CALLE TAMPICO BETWEEN AVENIDA RAMIREZ AND AVENIDA
CARRANZA
160'
BASIS OF BEARING.
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CENTERLINE OF
DESERT CLUB DRIVE AS SHOWN ON PARCEL MAP NO. 30850, ON
FILE IN BOOK 206, AT PAGES 60 THROUGH 62, OF MAPS, O.R.
TAKEN AS: N 00'05'00" W
FEMA FLOOD ZONE'
THE PROJECT IS COVERED BY FIRM PANEL NUMBER 06085C2241H
REVISED APRIL 19, 2017. THIS MAP INDICATES THAT THE PROJECT
AREA IS DESIGNATED AS ZONE X (SHADED), INDICATING AREAS OF
0.2% ANNUAL CHANCE FLOOD; AREAS OF 1% ANNUAL CHANCE
FLOOD WITH AVERAGE DEPTHS OF LESS THAN 1 FOOT OR WITH
DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AND AREAS
PROTECTED BY LEVEES FROM 1% ANNUAL CHANCE FLOOD.
INSURANCE PURCHASE IS NOT REQUIRED IN THESE ZONES.
PREPARED UNDER THE DIRECT SUPERVISION OF
SIGNATURE ( -
JULIAN A. DE LA TORRE RCE: 43880
R.C.E. NO.
C43880
DESIGNED BY
BTE
DATE
,41641-7
DRAWN BY
BTE
CHECKED BY
JAD
APPROVED FOR PERMITTING:
CITY OF LA QUINTA
ire ar
BURT HANAD
BUILDING OFFICIAL
CRY OF LA QUINTA
DATE
PLANNING & ZONING COMPLIANCE
I/-
GABRIEL PE 1PLANNING A„
CITY OF LA QUINTA
DAT
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE STANDARD PLANS OF THE CITY OF LA QUINTA AND THE
LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION.
2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO APPLY TO THE CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT FOR THE
NECESSARY PERMITS AND TO BE RESPONSIBLE FOR SATISFACTORY COMPLIANCE FOR ALL CURRENT ENVIRONMENTAL REGULATIONS DURING
THE LIFE OF CONSTRUCTION ACTIVITIES FOR THE PROJECT. ADDITIONAL STUDIES AND/OR PERMITS MAY BE REQUIRED.
3. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AS REQUIRED BY THE CITY OF LA QUINTA OR OTHER GOVERNING AGENCIES.
4. THE CONTRACTOR SHALL NOTIFY THE CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT FORTY-EIGHT (48) HOURS PRIOR TO ANY GRADING,
BRUSHING, OR CLEARING AND EACH PHASE OF CONSTRUCTION AT (760) 777-7048.
5. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE
EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY
AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, REPLACEMENT, OR RELOCATION OF ALL REGULATORY, WARNING AND GUIDE
SIGNS.
7. THE CITY ENGINEER SHALL APPROVE THE DESIGN AND INSTALLATION OF ALL STREET NAME SIGNS, TRAFFIC CONTROL SIGNS, TRAFFIC
STRIPING, LEGENDS, AND PAVEMENT MARKERS TYPE AND LOCATION.
8. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH MARKS NOTED ON THE PLANS, OR FOUND DURING
CONSTRUCTION. REMOVAL AND REPLACEMENT SHALL BE DONE BY A REGISTERED CIVIL ENGINEER WITH AN R.C.E. NUMBER BELOW 33,966,
OR A LICENSED LAND SURVEYOR ONLY.
9. CONSTRUCTION OPERATIONS AND MAINTENANCE OF EQUIPMENT WITHIN ONE HALF MILE OF HUMAN OCCUPANCY SHALL BE PERFORMED ONLY
DURING THE TIME PERIODS AS FOLLOWS:
OCTOBER 1ST TO APRIL 30TH: MONDAY THROUGH FRIDAY 7:OOAM TO 5:30PM
MAY 1ST TO SEPTEMBER 30TH: MONDAY THROUGH FRIDAY 6:OOAM TO 7:OOPM
WORK SHALL BE PROHIBITED ANY TIME ON SUNDAYS OR ON FEDERAL HOLIDAYS.
NO REDUCTION OF THE TRAVELED WAY WIDTH SHALL BE PERMITTED ON ANY CITY STREET ON WEEKENDS OR HOLIDAYS, OR WHEN ACTIVE
WORK IS NOT BEING DONE, UNLESS PRIOR AUTHORIZATION TO DO SO IS GRANTED BY THE CITY ENGINEER.
NO LANE CLOSURES SHALL BE PERMITTED OR ALLOWED ON ANY CITY STREET BEFORE 8:30AM AND AFTER 3:30PM UNLESS AUTHORIZATION
TO DO SO IS GRANTED BY THE CITY ENGINEER.
10. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF ALL DIRT, MUD AND DEBRIS DEPOSITED ON THEM AS A RESULT OF THE GRADING
OPERATION. CLEANING IS TO BE DONE TO THE SATISFACTION OF THE CITY ENGINEER.
11. ALL CONSTRUCTION AREAS SHALL BE PROPERLY POSTED AND LIGHTED IN CONFORMANCE WITH THE CALIFORNIA STATE MANUAL OF WARNING
SIGNS, LIGHTS, AND DEVICES FOR USE IN THE PERFORMANCE OF WORK UPON HIGHWAYS IN ORDER TO ELIMINATE ANY HAZARDS.
12. CONSTRUCTION PROJECTS DISTURBING MORE THAN 1 -ACRE MUST OBTAIN A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
PERMIT. OWNERS/DEVELOPERS ARE REQUITED TO: A) FILE A NOTICE OF INTENT (N01) WITH THE STATE WATER RESOURCES CONTROL BOARD
(SWRCB); B) PREPARE A STORM WATER POLLUTION PREVENTION PLAN (SWPPP); AND C) HAVE A MONITORING PLAN FOR THE SITE. THE
NPDES IS A NATIONAL PROGRAM TO CONTROL NON -POINT SOURCE POLLUTANTS CARRIED BY STORM WATER. THE PROGRAM IS
IMPLEMENTED AND ENFORCED BY THE SWRCB.
GRADING NOTES
1. GRADING SHALL BE IN ACCORDANCE WITH THE ENGINEERED GRADING REQUIREMENTS OF THE UNIFORM BUILDING CODE, LATEST EDITION, AND
SOILS REPORT, NO.544-1478. 02-04-246 DATED:APRIL 17. 2002. PREPARED BY:SLADDEN ENGINEERING, TELEPHONE N0.760-772-3893.
2. THE SOILS ENGINEER AND THE ENGINEERING GEOLOGIST SHALL EXERCISE SUFFICIENT SUPERVISORY CONTROL DURING GRADING TO INSURE
COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN THEIR PURVIEW.
3. THE DESIGN CIVIL ENGINEER SHALL EXERCISE SUFFICIENT CONTROL DURING GRADING AND CONSTRUCTION TO ENSURE COMPLIANCE WITH THE
PLANS, SPECIFICATIONS, AND CODE WITHIN HIS PURVIEW.
4. DURING ROUGH GRADING OPERATIONS AND PRIOR TO CONSTRUCTION OF PERMANENT DRAINAGE STRUCTURES, TEMPORARY DRAINAGE
CONTROL SHALL BE PROVIDED TO PREVENT PONDING WATER AND DAMAGE TO ADJACENT PROPERTY.
5. AFTER CLEARING, EXISTING GROUND SHALL BE SCARIFIED TO A MINIMUM OF 6" ON THE ENTIRE SITE OR AS RECOMMENDED BY THE SOILS
REPORT.
6. THE MAXIMUM CUT AND FILL SLOPES SHALL BE 2:1.
7. PADS SHALL BE COMPACTED TC) A MINIMUM OF 90% RELATIVE DENSITY PER A.S.T. M. SPECIFICATIONS AND THE ABOVE MENTIONED SOILS
REPORT.
8. MINIMUM BUILDING PAD DRAINAGE SHALL BE 2%. DRAINAGE SHALL BE A MINIMUM OF 0.3' DEEP AND BE CONSTRUCTED A MINIMUM OF 2'
FROM THE TOP OF CUT OR FILL SLOPES. THE MINIMUM SLOPE OF SWALES SHALL BE 0.50%.
9. ALL FILLS SHALL BE COMPACTED TO A MINIMUM OF NINETY (90) PERCENT OF MAXIMUM DENSITY AS DETERMINED BY THE UNIFORM
BUILDING CODE SECTION 7010 OR EQUIVALENT AS APPROVED BY THE CITY ENGINEER. FIELD DENSITY SHALL BE DETERMINED IN
ACCORDANCE WITH THE UNIFORM BUILDING CODE SECTION 7002, OR EQUIVALENT, AS DETERMINED BY THE CITY ENGINEER.
10. ALL STREET SECTIONS ARE TENTATIVE. THE MINIMUM SECTION IS 3" A.C. OVER 4.5" CRUSHED A.B. ADDITIONAL SOIL TEST(S) SHALL BE
REQUIRED AFTER ROUGH GRADING TO DETERMINE EXACT SECTION REQUIREMENTS. THE CITY ENGINEER SHALL APPROVE THE FINAL STREET
SECTION.
11. THE CITY ENGINEER WILL REVIEW FOR APPROVAL THE FINAL STREET SECTIONS AFTER SUBMITTAL OF "R" VALUE TESTS FOR ROADWAY
SUBBASE.
12. LOCATIONS OF FIELD DENSITY TESTS SHALL BE DETERMINED BY THE SOILS ENGINEER OR APPROVED TEST AGENCY AND SHALL BE
SUFFICIENT IN BOTH HORIZONTAL AND VERTICAL PLACEMENT TO PROVIDE REPRESENTATIVE TESTING OF ALL FILL PLACED. TESTING IN AREAS
OF A CRITICAL NATURE OF SPECIAL EMPHASIS SHALL BE IN ADDITION TO THE NORMAL REPRESENTATIVE SAMPLINGS.
13. THE FINAL COMPACTION REPORT AND APPROVAL FROM THE SOILS ENGINEER SHALL CONTAIN THE TYPE OF FIELD TESTING PERFORMED.
EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING, AND
SHALL BE 50 NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATION SHALL BE PERFORMED TO VERIFY THE ACCURACY OF
THE MAXIMUM DENSITY CURVES USED BY THE FIELD TECHNICIAN.
14. ALL UNDERGROUND FACILITIES, WITH LATERALS. SHALL BE IN PLACE AND INSPECTED PRIOR TO PAVING, INCLUDING BUT NOT LIMITED TO.
THE FOLLOWING: SEWER, WATER. ELECTRIC, COMMUNICATIONS, GAS, AND DRAINAGE.
15. THE FINAL UTILITY LINE BACKFILL REPORT FROM THE PROJECT SOILS ENGINEER SHALL INCLUDE AN APPROVAL STATEMENT THAT THE
BACKFILL IS SUITABLE FOR THE INTENDED USE.
16. BLOCK WALLS ARE NOT PART OF THE GRADING PERMIT. PLEASE SUBMIT THESE FOR SEPARATE BUILDING PERMIT(S).
17. THE CONTRACTOR IS RESPONSIBLE TO PREVENT SILT CONTAMINATION OF STORMWATER INFILTRATION FACILITIES DURING CONSTRUCTION OF
SUBSEQUENT IMPROVEMENTS BY THE CONTRACTOR. IMMEDIATELY PRIOR TO FINAL ACCEPTANCE OF STORM DRAINAGE
RETENTION/INFILTRATION FACILITIES, THE CONTRACTOR SHALL CONDUCT, IN THE PRESENCE OF THE CITY INSPECTOR, A PERFORMANCE TEST
DESIGNED TO CLEARLY DEMONSTRATE THE FUNCTIONAL ADEQUACY OF THE FACILITIES.
18. THE CONTRACTOR SHALL PROVIDE WIND EROSION AND DUST CONTROL MEASURES AS REQUIRED BY THE FUGITIVE DUST CONTROL PLAN
APPROVED FOR THIS PROJECT. ALL MEASURES SHALL BE TO THE SATISFACTION OF THE CITY.
PAVING NOTES
1. ALL UNDERGROUND FACILITIES, INCLUDING SERVICE LATERALS, SHALL BE IN PLACE WITH TRENCHES COMPACTED AND TESTED PRIOR TO
BASE GRADE INSPECTION AND PAVING. THE CONTRACTOR SHALL SUBMIT TO THE CITY WRITTEN EVIDENCE ISSUED BY THE RESPECTIVE UTILITY
PURVEYOR INDICATING THE SUBSURFACE PORTION OF THEIR UNDERGROUND FACILITIES HAS BEEN INSTALLED AND ACCEPTED.
2. LANE CLOSURES AND DETOURS SHALL BE POSTED, DELINEATED, AND LIGHTED IN CONFORMANCE WRH THE CALTRANS MANUAL OF TRAFFIC
CONTROLS FOR CONSTRUCTION AND MAINTENANCE WORK ZONES AND ANY ADDITIONAL REQUIREMENTS DEEMED NECESSARY BY THE CITY
ENGINEER.
3. ASPHALT CONCRETE PAVING, EXCEPT FOR OVERLAYS, SHALL BE INSTALLED IN TWO (2) OR MORE COURSES WITH MIX DESIGNS THAT
CONFORM TO SECTION 400 OF THE REVISED STANDARD SPECIFICATIONS, COACHELLA VALLEY VERSION (GREEN BOOK), NOTED AS FOLLOWS:
WEARING COURSE (UPPER COURSE): IIIA-C2-PG70-10
BASE COURSE (LOWER COURSES): IIIB-B3-PG70-10
THE WEARING COURSE SHALL BE 0.1 FEET THICK; THE BASE COURSE(S) SHALL CONTAIN THE BALANCE OF THE REQUIRED ASPHALT
CONCRETE THICKNESS.
4. MIX DESIGN REQUIRED: FOURTEEN (14) DAYS PRIOR TO COMMENCEMENT OF PAVING OPERATIONS, THE CONTRACTOR SHALL SUBMIT FOR CITY
APPROVAL, A COMPLETE PROPOSED MIX DESIGN IDENTIFYING THE MIX CHARACTERISTICS SUCH AS AGGREGATE GRADATIONS, VOIDS IN
MINERAL AGGREGATE (VMA), AIR VOIDS, AND S -VALUE FOR VARIOUS OIL CONTENTS FOR EACH MIX.
5. A TACK COAT SHALL BE APPLIED TO EXISTING PAVEMENT, P.C.C. SURFACES, AND THE A.C. BASE COURSE, IF TRAFFIC HAS DRIVEN ON IT.
THE TACK COAT SHALL BE SLOW SETTING ANIONIC EMULSIFIED ASPHALT TYPE "SS -1H" CONFORMING TO SECTION 203-3 OF THE STANDARD
SPECIFICATIONS. THE LIQUID ASPHALT SHALL BE GRADE 60-70 AND APPLIED AT THE RATE OF 0.1 GALLONS/YARD.
6. NEW IMPROVEMENTS THAT JOIN EXISTING IMPROVEMENTS SHALL JOIN OR MATCH IN A MANNER SATISFACTORY TO THE CITY ENGINEER.
CONSTRUCTION OPERATIONS REQUIRED TO ACHIEVE A SAFE, DURABLE, AESTHETICALLY PLEASING TRANSITION BETWEEN THE NEW AND
EXISTING IMPROVEMENTS MAY INCLUDE SAW CUTTING, REMOVAL REPLACEMENT, CAPPING, AND/OR COLD PLANNING, AS NEEDED.
7. ALL MANHOLES AND VALVE BOX FRAMES SHALL BE ADJUSTED TO FINAL GRADES AFTER PAVEMENT INSTALLATION IS COMPLETED.
8. THE CURB SHALL BE ETCHED OR STAMPED SHOWING UTILITY SERVICE LATERAL LOCATIONS AS FOLLOWS:
"S" FOR SEWER
"G" FOR GAS
"E" FOR ELECTRICAL POWER.
APPROVED BY CITY OF LA QUINTA
BRYAN MCKINNEY, P.E.
INTERIM CITY ENGINEER
R.C.E. 49418 EXPIRES 9/30/18
6rc47
DATE
CITY OF LA QUINTA, CALIFORNIA
OLD TOWN LA QUINTA PLAZA IMPROVEMENTS
PAVEMENT REPLACEMENT PLAN
COVER SHEET
PORTIONS OF LOTS "B" & "E" OF PM 206/60-62, SECTION 6, TOWNSHIP 6 SOUTH, RANGE 7 EAST, S.B.M.
%mri-0005-
SHEET
1
OF
SHEETS
MSA Consulting
0
0
0
R:\1536\ACAD\GradingWnden Plaza \1536 PG 01.dwg, 6/16/2017 7:15:26 AM,
Dig Alert
DIAL TOLL FREE
1-800-227-2600
AT LEAST TWO DAYS
BEFORE YOU DIG
N0.
REVISIONS
/
i
' - ...--'
\ '
\ ,-- �/ /
\ \ i
0
Z'
/
EXI II(G JOINT ❑
LA"ILITY TRENCH
/
/ :"/i7/ ///
-- //// / -/.'.
/'c//o/ /I/
/ //// /
G ///2. //
/// /
S
S
0
c
i
/
i
513\/
\\
EXISTI►C ¥Q"
WATERNMAI'N \ /
r \y/
\
/
taC
i
i
i
11 \
f/
\ftztB
EXISTING JGINT
�I UTILITY TRENCH
CURB
/
EXISTING 6" SEWER
❑1 EXISTING 2" GAS
G
r
0
I \
\s`
\ \ \ \ \ \
\\\
\\ \.
\\
\ \ \\ \
® r \
\
1❑EX. 6" SD
DRYWELL'® )� \\
\\
i
/EXISTING JOINT
\ ❑1 UTILITY TRENCH
J
EX. 12" SD
CATCH
\ BASIN
EXISTING BUILDING "C"
78086 MAIN STREET
\ / VERIZON
\ MANHOLE
e
EXISTING BUILDING 'A"
78015 MAIN STREET
WATER
METERS
(7)
FDCQPPI
DETE4TOR
CHE
METED
MIMS
anis
MIS MIMS
LTJ
IIMP
—T —
IIMMI
— FO
TRANSFORMER
II
- LIMIT OF DEMO- I
NM MO a M M
—T —
FO
IT� 411.11 411.
FO
APPROVED
DATE
FO
-
/////
SAWCUT AT FACE
OF EX. CURB
LI HT 0'
V -GUTTER U � I
—=---
- FO
rot
EX. 12/Y1❑
1 EXISTIER NNG 12"
WAT
4-
T
ORD
FO ••••
ict
L
MIS
r 21-2 IIIc
EX. FIBER OPTIC ❑1
AND TELEPHONE
— — OM =
r
FO -
0'
AVENIDA LA FONDA
0
10'
EN NM
I= 1= INN
20'
SCALE 1"=10'
Li)
MSA CONSULTING, INC.
o o PLANNING ■ Ova. &niu tmo ■ LAND Suavnaa+
is Boa BHos in ■ ammo Mama • CA 92270
lbrp 0, Tasman (760) 320-9511 ■ PAN (760) 323-7593
BENCH PD 104-70
MARK
ELEV.
47.998
(NGVD29 DATUM)
LOCATION BRASS CAP IN CONCRETE MONUMENT ON SOUTH SIDE
CALLE TAMPICO BETWEEN AVENIDA RAMIREZ AND AVENIDA
CARRANZA
PREPARED UNDER THE DIRECT SUPERVISION OF
SIGNATURE 'GLi 0
Oa
JULIAN A. DE LA TORRE RCE: 43880
R.C.E. NO.
C43880
DESIGNED BY
BTE
DATE
DRAWN BY
BTE
CHECKED BY
JAD
30'
n
DEMOLITION NOTES
C -PROTECT IN PLACE ITEM PER PLAN.
C -REMOVE EXISTING 6" THICK CONCRETE
3i -REMOVE EXISTING 4" THICK CONCRETE
(FOR PERMIT PURPOSES ONLY) QvryIi lES
N/A
4,685 SF
3,040 SF
329 LF
125 LF
1 EA
80LF
260 SF
N/A
210 SF
N/A
DRIVE AISLE.
SIDEWALK AND TILE.
4n-SAWCUT EXISTING CONCRETE AS SHOWN.
SAWCUT AND REMOVE EXISTING 3' WIDE CONCRETE V -GUTTER.
REMOVE EXISTING FOUNTAIN PER SEPARATE PERMIT.
REMOVE EXISTING WROUGHT IRON FENCE AND GATES.
B�-SAWCUT AND REMOVE EXISTING CONCRETE CURB RAMP AND CURB.
PROTECT IN PLACE EXISTING CURB, REMOVE EXISTING RED PAINT AS REQ'D.
10 SAWCUT AND REMOVE EXISTING PAVER CROSSWALK.
11 -PROTECT IN PLACE EXISTING TREES, LANDSCAPE, AND IRRIGATION.
CONTRACTORS NOTE' DRYWELL PROTECTION AND MAINTENANCE
PROTECTION OF THE NEW AND EXISTING DRYWELL DUPING BALANCE OF
CONSTRUCTION AND GROW -IN OF RETENTION BASIN
1. PROVIDE SANDBAGS AROUND CATCH BASIN INLETS UNTIL FINAL GROW -IN OF RETENTION BASIN.
2. SEAL GRATED INLET WITH PLASTIC TO BOTH THE EXISTING AND THE NEW DRYWELL.
3. INSTALL SOD SURROUNDING BOTH GRATED INLETS (MINIMUM OF 10FT. RADIUS).
4. SEAL THE PIPE INLETS INTO THE DRYWELLS BY COVERING WITH PVC CAP OR PLASTIC.
5. OVERSEED RETENTION BASIN AND STABILIZE BANKS (REFER TO APPROVED LANDSCAPE PLANS).
6. MONITOR IRRIGATION TO AVOID OVER WATERING OR FAILED SPRINKLER HEADS.
7. DO NOT REMOVE SEALED COVERS, GRATED INLETS OR PLASTIC CAPS ON PIPE INLETS, OR SANDBAGS UNTIL
RETENTION BASIN TURF HAS GROWN IN AND STABILIZED.
8. REMOVE ANY SILT OR SEDIMENT FROM DRYWELL CHAMBERS BEFORE ACTIVATING FOR USE.
9. MONITOR ALL ON-SITE CONSTRUCTION ACTIVITIES AND PROHIBIT THE WASH DOWN OR DUMPING OF
CONCRETE, STUCCO, GROUT OR ANY ASSOCIATED PRODUCTS INTO THE GUTTER AND STORM DRAIN SYSTEM.
LONG-TERM MAINTENANCE OF DRYWELLS
1. ESTABLISH PERIODIC INSPECTION PROGRAM. INCLUDE, AS A MINIMUM, QUARTERLY REMOVAL OF THE GRATED
COVERS AND INSPECTION FOR SILT OR SEDIMENT IN DRYWELL SEDIMENTATION CHAMBERS.
2. INSPECT CATCH BASINS AND DRYWELLS AFTER ANY STORM EVENT OF SIGNIFICANCE FOR SEDIMENT BUILDUP.
3. MONITOR NUISANCE WATER RUNOFF PERIODICALLY; EXCESS LANDSCAPE IRRIGATION WHICH RESULTS IN
STREET RUNOFF CAN TAX THE DRYWELL OVER TIME. MAKE CERTAIN THAT RETENTION BASIN IS NOT
WATERED EXCESSIVELY FOR EXTENDED PERIODS.
4. EITHER MANUALLY OR USING VACUUM TRUCK SERVICE, CLEAN OUT THE DRYWELL CHAMBERS OF ALL
SEDIMENT ON AN AS -NEEDED BASIS.
5. DO NOT ALLOW THE SEDIMENT TO BUILD TO THE LEVEL OF THE OVERFLOW PIPE IN ANY EVENT. ONCE
SEDIMENT ENTERS THE DRYWELL BELOW THE SEDIMENTATION CHAMBER, THE WELL CAN BECOME
CONTAMINATED AND THE VOIDS MAY CLOG.
6. PROVIDE A WRITTEN LOG OF THE INSPECTIONS AND CLEAN OUT FREQUENCIES, SO THAT THE DRYWELLS CAN
BE MONITORED IN THE FUTURE WITH THE PROPER FREQUENCY.
CONTRACTOR NOTE' STORM DRAIN MAINTENANCE DURING
CONSTRUCTION AND LONG TERM
ALL INSTALLED STORM DRAIN INLETS, CATCH BASINS, JUNCTION STRUCTURES AND PIPELINES MUST BE
PROTECTED FROM DEBRIS DURING CONSTRUCTION AND PRIOR TO COMPLETION AND GROW -IN PERIOD FOR
LANDSCAPING. ONCE THE PROJECT IS COMPLETED AND ALL SOIL SURROUNDING THE INLETS/CATCH BASINS IS
STABILIZED, MAINTENANCE MUST BE PERFORMED ON A REGULAR BASIS. IF REGULAR MAINTENANCE/CLEANING IS
NOT PERFORMED, THE SYSTEM MAY FAIL RESULTING IN DAMAGE TO THE PROJECT.
APPROVED BY CITY OF LA QUINTA
71/141-
NEYG
BRYKINDATE
INTERIM CITY ENGINEER
R.C.E. 49418 EXPIRES 9/30/18
CITY OF LA QUINTA, CALIFORNIA
OLD TOWN LA QUINTA PLAZA IMPROVEMENTS
PAVEMENT REPLACEMENT PLAN
DEMOLITION PLAN
PORTIONS OF LOTS "8" & "E" OF PM 206/60-62, SECTION 6, TOWNSHIP 6 SOUTH, RANGE 7 EAST, S.B.M.
?E2o17 —0 0o5
SHEET
2
3
SHEETS
R:\ 1536\ACAD\Grading \Linden Ploza\1536 PG 02.dwg, 6/16/2017 7:43:25 AM, beichenauer, MSA Consulting, Inc.
/
i
/
7
/
/ p
/
7
i
4 /
vvv
e
/
V -GUTTER
I IIQG JOINT O
TRENCH
T/
TC 42.44
FS (42.
\ ,k. 2.38
4 .0
VAULT
VCATV
ULT
EXISTING
BUILDING
"Aw
'1
VARIES
EX. SIDEWALK-'
TO REMAIN
PROP. DECORATIVE PAVERS,
EX. SIDEWALK TO BE REMOVED
31'
C/L OF
FLOWLINE
13'
VARIES
EX. CURB TO REMAIN 0
PROP. PAVERS LEVEL
WITH TOP OF CURB
RAMP
2% MAX
EX. CONC. DRIVE AISLE ANDD
RIBBON GUTTER TO BE REMOVED,
SEE DEMOLITION PLAN ON SHEET 2
r �
-S
Ik
_!./ WATER M
V -GUTTER
Oi EXISTING 6" SEWER
-c —
G
1
1
rfi
/
42.80
1
EXISTING BUILDING "C"
78065 MAIN STREET
4]
L
EXISTING BUILDING "A"
78015 MAIN STREET
1 WATER
METERS
(7)
FDC
DETECTOR
HECK
IRR.
DETER
r
/
1
1
II —��
- -T -
— —41111111
FO
/
ADA PATH OF TRAVEL
1RANSF¢RMER
1
LIM
�-I — —T- T -L- -
-
FO - FO - - FO FO -
-� . • ' X.FS
)tE
TC 42.55
FS 42.05) FL (42.02)
V- GUTTER
B ..__
-
4 tot
r*
UG
TC
O FS (41.:9)
UR= 0
—
FO
1
— —
(42.55)
X.FS
J
ADA PATH OF TRAVEL
— —
T
— -
- T
FO
L
--
T -
- FO -
--
FO .-- -
- T
- F
S
Dig i Alert
DIAL TOLL FREE
1-800-227-2600
AT LEAST TWO DAYS
BEFORE YOU DIG
NO.
REVISIONS
AVENIDA LA FONDA
APPROVED
DATE
0
EXISTING 12"
WATER AWN 1
t
MSA CONSULTING, INCNNIN
PLANNING ■ CIYI. SIW z nio ■ LAND Mamma
•
34200 Dom Hors Diva • RAIIDao lima ■ CA. 92270
Spy istt 'Manna (760) 320-9611 ■ Fn (760) 323-7593
BENCH PD 104-70
MARK
ELEV.
47.998
(NGVD29 DATUM)
LOCATION BRASS CAP IN CONCRETE MONUMENT ON SOUTH SIDE
CALLE TAMPICO BETWEEN AVENIDA RAMIREZ AND AVENIDA
CARRANZA
PREPARED UNDER THE DIRECT SUPERVISION OF
SIGNATURE
JULIAN A. DE LA TORRE RCE: 43880
EX. CURB
/TN 0 REMAIN
PROP. DECORATIVE PAVERS,
EX. SIDEWALK TO BE REMOVED
SECTION "A - A"
NOT TO SCALE
CONSTRUCTION NOTES
2% MAX.
DIMING
BUILDING
i, r
(FOR PERMIT PURPOSES ONLY) QUANTITIES
Q PROTECT IN PLACE ITEM PER PLAN. N/A
®0- INSTALL DECORATIVE CONCRETE PAVERS OVER 1" BEDDING SAND OVER 3,645 SF
"MM PER DETAIL HEREON (SIDEWALK). SEE LANDSCAPE PLANS FOR PAVER
DETAILS/SPECS.
INSTALL DECORATIVE CONCRETE PAVERS OVER 1" BEDDING SAND OVER 4,285 SF
6" CMB MINIMUM PER DETAIL HEREON (DRIVE AISLE). SEE LANDSCAPE PLANS FOR
PAVER DETAILS/SPECS.
CONSTRUCT CONCRETE SIDEWALK PER CITY OF LA QUINTA STD. DWG. NO. 240. 92 SF
ADJUST EXISTING CATCH BASIN TO PROPOSED GRADE AND REPLACE EXISTING GRATE 1 EA
WITH J&R CONCRETE PRODUCTS STEEL HEEL -PROOF BOLTDOWN PARKWAY GRATE OR
APPROVED EQUAL.
PROTECT IN PLACE EXISTING TREES, LANDSCAPING, AND IRRIGATION. N/A
ADJUST EXISTING DRYWELL LID TO PROPOSED GRADES. 1 EA
ADJUST EXISTING GREASE TRAP ACCESS HATCH TO PROPOSED GRADES. 4 EA
ADJUST EXISTING WATER VALVE CANS TO PROPOSED GRADES PER CVWD STD. DWG. NO. 2 EA
W-17 & W-18.
MATCH EXISTING FINISHED SURFACE. N/A
MATCH EXISTING FINISHED FLOOR AT DOORWAY (FF -1/4"). N/A
PROTECT IN PLACE EXISTING CURB, REMOVE EXISTING RED PAINT AS REQ'D. N/A
INSTALL BOLLARD PER DETAIL HEREON. SEE LANDSCAPE PLANS FOR DETAILS/SPECS. 5 EA
CONSTRUCT 6" CURB PER CITY OF LA QUINTA STD. DWG. 210. 103 LF
ADJUST EXISTING VERIZON MANHOLE TO PROPOSED GRADES, COORDINATE W/ VERIZON. 1 EA
REMOVABLE POTTED PLANT, SEE LANDSCAPE PLANS FOR DETAILS/SPECS. 9 EA
WROUGHT IRON FENCE, SEE LANDSCAPE PLANS FOR DETAILS/SPECS. 75 LF
6" MIN. WIDTH OR EQUAL
CONCRETE EDGE RESTRAINT
0' 10' 20' 30' 40'
ME MIN
1 — I
R.C.E. NO.
C43880
SCALE 1"=10'
DESIGNED BY
BTE
DATE
L114117
DRAWN BY
BTE
CHECKED BY
JAD
APPROVED BY CITY OF LA QUINTA
'
B MCKINNEY, P.E. DATE
INTERIM CITY ENGINEER
R.C.E. 49418 EXPIRES 9/30/18
SAND FILLED JOINTS PER
ASTM C33 OR EQUAL
a
e . .
l r
i=i la
11.E1 I-1 I-1 i_I Inn
I
f
fot
11__!II_
INTERLOCKING CONCRETE PAVERS.
SIZE. TYPE, AND COLOR PER
LANDSCAPE PLANS.
1" BEDDING SAND PER
ASTM C33 OR EQUAL.
4" MINIMUM CMB 95* COMPACTED
PER ASTM D1557, DEPTH VARIES
4"-8" AS REQ'D.
12" SUB GRADE 90% COMPACTED
PER ASTM D1557
EXISTING SUBGRADE
al
SEEESSEEPARATE LANDSCAPE ARCHITECT'S PLANS FOR
PAVER DETAILS AND SPECIFICATIONS.
DECORATIVE PAVERS
NTS
i+)
BOLLARD BY QUICKCRETE
1/2" DIA. X 4 1/2" LENGTH ANCHOR
2" DIA. X 5" DEEP GROUT POCKETS,
FILLED W/ NON -SHRINK GROUT
EXISTING STREET
1111-111-116
CONCRETE FOOTING
95* COMPACTED SUB -GRADE
REMOVABLE BOLLARD g
(SHOWN FOR REFERENCE ONLY, SEE LANDSCAPE
PLANS FOR DETAILS AND SPECS.)
NTS
CITY OF LA QUINTA, CALIFORNIA
OLD TOWN LA QUINTA PLAZA IMPROVEMENTS
PAVEMENT REPLACEMENT PLAN
PAVEMENT REPLACEMENT PLAN
PORTIONS OF LOTS "B" & "E" OF PM 206/60-62, SECTION 6, TOWNSHIP 6 SOUTH, RANGE 7 EAST, S.B.M.
P6 -2o17-- pooS-
SHEET
3
SHEETS
R:\1536\ACRD\Grading\Linden Plaza\1536 PG 03.dwg, 6/16/2017 1:53:06 PM, beichenauer, MSA Consulting, Inc.