14-650 (RER)78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: RER-14-650
Property Address: 51180 AVENIDA OBREGON
APN: 773052008
Application Description: REM / ADDITION
Property Zoning:
Application Valuation: $230,00000.0
Applicant: l
1�
n =
D`VOICE (760) 777-7125
FAX (760) 777-7011
COMMUNITY DEVELOPMENTDEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 8/11/2014
Owner:
KIM�:DAVIS
•51-180 OBREGON
'.LA QUINTA, CA 92253
Contractor:
A &M CONSTRUCTION
�n 78-076 CA LLE CADIZ
I I LA QUINTA; CA 92253
AUG 11.1014
CITY OF LA QUIN I A
,v ncvcinPMENTDEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License
Class: _u License No.:
Date" 3 ��I t l Contractor:
V
v
OWN ER -BU ILDE ECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State.
License Law for the following reason (Sec. 7031., 5, Business and Professions Code: Any '
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires.the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he'or she isexempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of.noi more than five hundred dollars
($500).:
(� 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the'structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code:, The' Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who doe's.the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion; the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of: sale.).
(_) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' .
State License Law does not apply to an owner of property who.builds or improves.
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a' construction lending agency for
the performance of the work for which this permit is issued. (Sec. 3097, Civ: C.).
Lender's Name:
Lender's Address:
(760)774-8225
Llc. No.:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation; as provided for by Section 3700 of the Labor Code, for the performance
So' for which this permit is issued.
have and will maintain workers' compensation insurance, as required by
50 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3 0 of the Labor Code, I shall forthwith
complywiththose provisions.
Date/y(� Applicant:
WARNING: FAILURE TO.SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL'SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, -DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST; AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restiictions-set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall.defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees•forany actor omission related;to the work being performed under or
following,issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced `within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject.perrnit tb cancellation.
1 certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and sta laws relating to building
cohistruction, and hereby authorize representatives of this;(IRo enter upon the above-
mentioned property for inspection purposes.
.1��l
DatreJSignature (Applicant or Agent):<
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT
QTY
AMOUNT
" PAID'
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$61.49
$61.49
8/11/14
PAID BY
METHOD ' '
RECEIPT:#
CHECK#.,
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION
ACCOUNT
QTY
''AMOUNT.
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.16
$17.16
8/11/14
PAID BY.
_ METHOD
RECEIPT #
'CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION
ACCOUNT.
QTY
AMOUNT..
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.12
$120.12
8/11/14
PAID BY
METHOD .
RECEIPT .# °�
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION'
ACCOUNT
QTY .
AMOUNT
PAID °
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$168.74
$168.74
8/11/14
,'.PAID BY
METHOD -
, RECEIPT #
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid forADDITION: $367.51 $367.51
DESCRIPTION -'ACCOUNT
QTY
AMOUNT
- PAID,
PAID,DATE
BSAS SB1473 FEE
101-0000-20306
0
$10.00
$10.00
8/11/14
PAID BY,
METHOD
RECEIPT#
CHECK #,
CLTD BY,
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid forBU1LDING STANDARDS ADMINISTRATION BSA $10.00 $10.00
DESCRIPTION
ACCOUNT. '`
QTYAMOUNT
`
PAID`PAID
DATE
HOURLY PLAN CHECK - YES
101-0000-42600
3.5
$245.00
$245.00
8/11/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION
... ,ACCOUNT,
QTY
AMOUNT :,.
PAID
PAID'DATE
HOURLY PLAN CHECK - YES
101-0000-42600
3.25
$227.50
$227.50
8/11/14
. PAID`BY
METHOD . _
RECEIPT ,# _
CHECK #
-.CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid for CITY STAFF - PER HOUR: $472.50 $472.50
DESCRIPTION;,, i
ACCOUNT
QTY
.'AMOUNT' .
.'PAID ; .
.PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$143.00
$143.00
8/11/14
PAID BY'
METHOD " ,
RECEIPT #
CHECK #..
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
:DESCRIPTION .,
ACI'llCOUNT11 .
QTY
AMOUNT
"'PAID,
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.19
$47.19
8/11/14
PAID BY
METHOD
RECEIPT #'
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $190.19 $190.19
DESCRIPTION
'. ACCOUNT ``
QTY
AMOUNT .
PAID
PAID DATE
HOURLY PLAN CHECK
10160003428200
$210.00
$210.00
8/11/14
PAID BY
-.<"r.. METHOD - �` .
': _r . ° RECEIPT #•"
CHECK #
-'CLTD BY:
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid forHOURLY PLAN CHECK: $210.00 $210.00
'DESCRIPTION .'
ACCOUNT -
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE. REPAIR/ALTERATION
101-0000-42402
0
$11.92
$11.92
8/11/14
PAID BY .
METHOD
RECEIPT #
CHECK #
-CLTD BY.:
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTIONACCOUNT
QTY
AMOUNT
PAID '
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.77
$4.77
8/11/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION... "
ACCOUNT .
AMOUNT
PAID
PAID, DATE
CONDENSER/COMPRESSOR
101-0000-42402
0
$71.50
$71.50
8/11/14
PAID. BY; •<
< . METHOD
RECEIPT #
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
=-DESCRIPTION
ACCOUNT
QTY
AMOUNT.'
PAID',PAIabATE
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$47.66
$47.66
8/11/14
PAID BY
METHOD
= _RECEIPT#
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION. =
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$11.92
$11.92
8/11/14
PAID, BY , ,._ . -
METHOD:
., RECEIPT #,
" CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION
ACCOUNTQTY'
. _ AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.77
$4.77
8/11/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
"DESCRIPTION
ACCOUNT -
QTY;
',• ,. AMOUNT
PAID
PAID:DATE
FURNACE
101-0000-42402
0
$71.50
$71.50
8/11/14
PAID.BY .
METHOD -_
R.ECEIPT #
CHECK #, :
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
`DESCRIPTION
ACCOUNT.
QTY
AMOUNT
PAID -
PAID DATE
FURNACE PC
101-0000-42600
0
$47.66
$47.66
8/11/14
PAID. BY ."
-: METHOD . -
RECEIPT #
CHECK # .
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION ':.-ACCOUNT
.. s
.QTY,
`• AMOUNT
PAID
PAID"DATE
VENT FAN
101-0000-42402
0
$23.84
$23.84
8/11/14
*PAID BY '.
METHOD
RECEIPT #
CHECK #
CLTD, BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION .` '. "` a
ACCOUNT = ,
QTY'
-.: 'AMOUNT .
PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$9.54
$9.54
8/11/14
PAID BY; „ ,
METHOD,
''RECEIPT
'CHECK # •:-
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid for MECHANICAL: $305.08 $305.08
DESCRIPTION,.'
ACCOUNT
QTY"`.
'. 'AMOUNT.'
= ,; PAID, .:
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$83.44
$83.44
8/11/14
PAID BY : ; '' "
METHOD`
RECEIPT # • '
CHECK # .
CLTD *6Y
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION +
". ' ACCOUNT
QTY
AMOUNT:.. -
:. PAID
"PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$83.44
$83.44
8/11/14
PAID BY _ .
, METHOD:
>'RECEIPT # ..:
CHECK # : "
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION .
- ''ACCOUNT
QTY.
AMOUNT.
PAID
PAID DATE
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$35.75
$35.75
8/11/14
PAID BY,,.
METHOD •
RECEIPT #.
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION ; : :'
. ' ACCOUNT
'QTY
AMOUNT. _K
PAID-'
PAID DATE
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$23.83
$23.83
8/11/14
PAID BY
* ` ° '.''"METHOD
RECEIPT #
CHECK.#
CLTD BY -
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION -
ACCOUNT
QTY
AMOUNT-
PAID
PAID DATE
WATER HEATER/VENT
101-0000-42401
0
$23.84
$23.84
8/11/14
,,PAID BY -
METHOD
RECEIPT #
CHECK #.
CLTD. BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION..
.ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT PC
101-0000-42600
0
$14.30
$14.30
8/11/14
PAID BY
METHOD '
RECEIPT #.
CHECK '#
':CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
'DESCRIPTION
,`ACCOUNTQTY
y AMOUNT -
PAID,
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$11.92
$11.92
8/11/14
PAID BY _
: METHOD
RECEIPT #
CHECK # "
"-,CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION.. •"
ACCOUNT ". ....
QTY `
AMOUNT-
PAID.
PAID. DATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$11.92
$11.92
8/11/14
= PAID:BY
_...., _- METHOD
i .RECEIPT #
CHECK #
CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
Total Paid for PLUMBING FEES: $288.44 $288.44
DESCRIPTION. '
ACCOUNT ..
QTY
AMOUNT;
PAID
PAID DATE.
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$128.70
$128.70
8/11/14
=' PAID BY
METHOD
RECEIPT # '" `
CHECK #
^CLTD BY
A &M CONSTRUCTION
CHECK
R668
11611
SKH
DESCRIPTION : s
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL•S00 SF PC
101-0000-4260
0
$102.96.
$102:96:
8/11/14
rigY r?PAI1Y
r,_e
''2
x sy t Zz"see�va
� RaEGE
CHEG #x '
Y:
BYE
�METHQODEs
#ss _
x -
CLTD
A &M CONSTRUCTION
'K < CHECK
R668'
11611
SKH
4x
N�
l�PAIiliilA
'�DECRI
�RAN
r-�
.•,
_
h
ri5::3`
m
.�.? .;.
mc
REMODEL, FIRST 100 SF
101 0000-42400 ;
0
s $48 62,
$48.62
8/11/14
to .
r.,an ,i" °Yf,Fi .. R` a '... h+l• .. -. _ -Wo.
Y` -
1; METHOD
'}c''S
.�?P.' i -"G.x-},,,„.
RECEIPf�#
y
r`tkei t+.+
CLT,D°BY'
till �00ul"Wra �.�� .
, C•.%. .o..ya.�z;.,,.Y ,!fir'.. Ove -W
--rc ,*.rd•:�.,rh."3sa�i,.�o„�rcev::53,;y.
§�CHECKg#
-4
A &M CONSTRUCTION
CHECK
R668•
11611
SKH
i �� {ka w j P/F G riXt'.� w 7t ° 7d
�a}y yDESCRIPTIO.N...
?v �7eutW y g9CLca
L,rACCO,IJNT PoQTY
r a
rc Fr
��AMOUNT
-?3
''PAID
{h sy Vt�;
PAID DAT:.Ex
.+1isa:;.n.'..�n..•.t:a^G• Ne,'.e;rf422:'�::"r+.Y�i-Lars.'.
'
.-.��n Is�..:.v..�"£z.,� :Ak�r> i4.v.�x-�,.:...bK`-3�.,.:.v�
,_,u, h•Yc-,�
§r
a.:T��iis.��'.33xe .�c,,i$
F
�:•?"aai'F.�-+�-.�i,.t�5Y.,�"`�...3�3r`f�x
',�GtM•rk .t',C. k:3Stes.
REMODEL, FIRST'S00 SF PC'.
-.'101-0000-42600J
0
$132;99
$132.99
8/,11/14
PAID$BY r�
�N
�METIIOD�a�CHECK
114"
#
r
rCLTD BY'r
9Vz��a.�`
h.�r..�.S'17........,..ti. �..
..,...i.,,..i »+aSFE4''.;S
A &M -CONSTRUCTION
CHECK
R668
11611
SKH
Total 'Pa id:forREMODEL: ' $41327, $413.27
Y ' ` .SDE CRIPTI N `" rg
n.� -,- w ADCC NT,..' �s
wal
� �� �<�{ �`� g iV"
AMOUNT
� 11 :'�
Wye
?AIDxDATE
s: r :., s 9.
" . y ti:U ria_
4N: ...
PAID ��
t'.'S,ta-.,:..P k2 �,_ :Z..'ii'hfS4w:f
ie'i.-'uk7'rS'
SMI - RESIDENTIAL
_ 101 0000=20308:
0 . $29:90
$29.90
8/11/14
p X
.N-iYr�T.;ew �y.� ::'&"�' '
�� x✓rElul,�
Elul.�PAIU BY
- Na?ap;2y77,A�wL'is. ., y
�r ?
'. Y:�e. ^,.5
RECEIPT#
fi,
CHECK6#
r.�+ x.n4�G1o?'N. .
:
y �
'is!„ .rcw.a•:.. Rd...HT1%`.".'n..s_r...._t•?^7^xr.... rT�
a METHOD
ai. -i5- ...,.r.f.�,�.xttv1.+.•va�'ut;t
h
:.-:''r
CL�TD BY
.^.tf �r;�;3',•
A &IVI CONSTRUCTION : '
CHECK
R668.
11611
SKH
Total Paid fo[.STRONG MOTION INSTRUMENTATION SMt $29 90 $29.90.
. :'. _ 4 .-...u.N.l. .1. -..k. Rl1y _.....a.iYh�.±•,, n+, .l .i.a�p'.&, 1�£�.-Y .. �:
1
==.�...ti Permit�Details nn
IT NUMBER
_ RCity` of La}C�uinta 'REWIA,650
Description: REM / ADDITION
FINANCIAL••
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL
Status: APPROVED
Applied: 5/19/2014
Approved: 8/11/2014 JJO
Parcel No: 773052008 Site Address: 51180 AVENIDA OBREGON LA QUINTA,CA 92253
Subdivision:
Block: lot:
Issued:
Lot Scl Ft:
Building Scl Ft:
Zoning:
Finaled:
Valuation: $230,000.00
Occupancy Type:
Construction Type:
Expired:
No. Buildings:
No. Stories:
No. Unites:
Details: REM/ ADDITION $230,000 TOTLA OF 9.75 HRS PLANCHECK
CONDITIONS _
Printed: Monday, August 11, 2014 10:37:37 AM 1 of 4
SYSTEMS
FINANCIAL••
•
} DESCRIPTION ''
ACCOUNT t ,"
QTY .
AMOUNT
PAID .
PAID DATE
RECEIPT #,
CHECK # .
METHOD
PAID BY
CLTD.
BY
ADDITION, EA
101-0000-42400
0
$61.49
$61.49
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH
ADDITIONAL 500 SF
ADDITION, EA
101-0000-42600
0
$17.16
$17.16
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH
ADDITIONAL 500 SF PC
ADDITION, FIRST 100 SF
101-0000-42400
1 0
1 $120.12
1 $120.12
1 8/11/14
1 R668
1 11611
1 CHECK
I A &M CONSTRUCTION
I SKH
Printed: Monday, August 11, 2014 10:37:37 AM 1 of 4
SYSTEMS
Printed: Monday, August 11, 2014 10:37:37 AM 2 of 4
SYSTEM S
'( _
����f,"F'A •Yk•m.,' ��:' ni p „_ �•tFX ° °� 0 A ` .y '
.. >
1', vR��,�•
��_ !i�.'9flyhj�.
- kkS
� - „��' :�'1�+.•��Yae�.
rzr Ti .v iTY
§¢
t
'ams
•:,•AM: ; NTrt�
ager
+�
P.AIU.
¢
U'ATE
ME,
a
1�-
�RECEIPT'#t
�M y»
!�'ST1�%t�k'�t •u
}CIiECKf#`METH
N. ��_
,'F•
D
e fq�#'- .
i E i .:
� 1.4 ' , � '
a p r ��
s,
ID
,.W ACCOUN e,
`at
wQ
k OU :"
._
,$}
O
tkP,
'PJftke<t^1.,.
..L.;�.:=it's.
"RvFfi7rAii-.�f��C
S•nA t9�utl4iiiC
.�.RSri 5'"k•
ADDITION; FIRST 100'SF
101-0000-42600
0
$168.74
' $168.74
8/11/14
R668
11611
CHECK.
A &M:CONSTRUCTION
SKH'
PC
_
,
Total Paid for -ADDITION: $367.51 $367.51
BSAS.SB1473 FEE
101-0000-20306.
0
$10.00
$10.00
8/11/14
11668
11611, ..
CHECK :
A &MCONSTRUCTION
SKH
Total'Paid forBUI,LDING STANDARDS`ADMINISTRATION
$10.00 $10.00
BSA:
HOURLY PLAN CHECK:-
101-000042600.
3.5
$245.06
$245.00
8/11/14
•:11668..*
11611
CHECK
A &M. CONSTRUCTION
.:SKH
YES
HOURLY PLAN CHECK -
101-0000--42600
3.25:
' $227.50
$227.56
8/11/14
R668 -
11611
CHECK
A &M CONSTRUCTION
:SKH'i
YES
..
Total'Paid forCITY STAFF -.PER HOUR: $472.50- $472:50`•..
RESIDENTIAL, FIRST
101.0000-42403
- .0
$143:00',
$143.00
8/11/14,
11668 :_-
11611
CHECK
A&MCONSTRUCTION
,SKH
1,000SF .
RESIDENTIAL, FIRST
1`060SF,.PC.
101=0000-42600
-0'. `..
$47.19
$47.19
8/11/14
R668
11611,
CHECK ,
'A &M CONSTRUCTION
SKH
Total Paid forELECTRICAL NEW CONSTRUCTION: $190:19 $190:19
HOURLY.PLAN CHECK
` 10160003428200
$210.00.$210.00
8/11/14
11668 ..;.
11611_
CHECK
A &M CONSTRUCTION
:,:
SKH
Total Paid forHOURLY`PL'AN,CHECK- $21000 $210:00
APPLIANCE
101-0000-42402
0:.$11.92:
$11:92
8/11/14
R668
11611 '
CHECK
A,&M CONSTRUCTION
.SKH
REPAIR/ALTERATION.
APPLIANCE..
101-000042600
0
$4:77
$4.77
8/11/14
R668
11611' `'
CHECK-
A`&M'CONSTRUCTION
SKH
REPAIR/ALTERATION, PC
CONDENSER/COMPRES
101-0000-42402'
0
$71.50
$71.50
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH
SOR
CONDENSER/COMPRES
101-0000-42600
0
$47.66
$47.66
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH
SOR PC
EXHAUST HOOD
101-0000-42402
0
$11.92
$11.92
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH .
EXHAUST HOOD PC
101-0000-42600
0'
$4.77
$4.77
8/11/14
R668
11611
TCHECK
A &M CONSTRUCTION
SKH
Printed: Monday, August 11, 2014 10:37:37 AM 2 of 4
SYSTEM S
--mt
Rao
N paw
Nil N -10, R, ®R
I MR - low. " I " 4- 1
PAIMD'
RE E.
I
- W-1
IFNI
W-'r-mr'
T,
-'AMOUNT ,y
,
Y,
"K.
FURNACE
101-0000-42402
0
$71.50
$71.50
8/11/14
R668
11611
CHECK
A -&M CONSTRUCTION
'SK SKH
FURNACE PC
-1011-0900-42600
0
$41X6
$41.'66
8/11/14
R668
11611
CHECK.
A &M CONSTA.U.'CTIbN.
SKH
VENT FAN
1010000-42402
0
-$23.84
$23.8.4,
8/11/14
R668
11611
CHECK
'A &M'CONSTRUCTION
SKH
VENT FAN PC
101-00.06-426-0,0
W
$9.54
7T
-8/11/14.
R668
11611
.(HECK
A &M CONSTRUCTION
SKH
ot Paid f
Total 'i " orMECHANICAL: $305:68 $305.08
FIXTURE/TRAP
.101-0000-42401'
0'
44,
-$81.44
-8j11j14
:k668
11611
CHECK
A &M CONSTRUCTION
'SKH
FIXTURE/TRAP PC
'10TL0000-42600
0.
$83.44.
$83-.44
8/11/14
R668
*11611
CHECK
A'&M-CdNSTRUC-T!ON
SKH
GAS.SYSTEM S+
101-090042401
0'
$35.75",
$35.75
8/11/i4.
'11668
11611,1:11.
",..CHECK
A -&M CONSTRUCTION
SKH
OUTC-ETS.:
GAS SYSTEM, S+
Zi'PC-
101-0000-42600
0.
$23.83
$23.83'
8/11/14
R668,'w
11611
CHECK
A 9,M CONSTRUCTION
-SKH
OUTLETS
WATER HEATF"ENT
101-0000-42401
�.$��4
•:$23.849
-$23.84
_;
1/14
-R668
11611.
CHECK w
A &m CONSTRUCTION
::SKH.
WATER HEATER/VENT
101-0000-42600
0
$14.30
$14.30
-8/11/14
-11668
11611
CHECK
A &M CONSTRUCTION
wSKH.'
K
WATER SYSTEM
INST/,kLT/REP
101-000042401 w
0
�1 1.92
$�j.9 . 2
8/wil/14'--
- .,R668
h6li
.CHECK
A*:&M CONSTRUCTION . . .
'KH.
S
WATER SYSTEM
101-0000-42600
0
$11.92
-$11.92'
8/11/14
R668.
11611
CHECK
A &M CONSTRUCTION
SKH
INST/ALT/REP PC
-
.Total Paid for PLUMBING FEES: $288.44 $288.44
REMODEL, EA ;-
w 101-0000-42400-- -
-$128.70
$128.70-,�.�
-8/11/14
R668-
11611
CHECK
X&M CONSTRUCTION
-'SKH-
ADDITIONAL 500 SF
REMODEL, EA
-
101-0000-42600
0
$102.96
$102.96
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF
1.01-000.0-42400
0
$48.62
$48.62
8/11/14
R668
1*1611
CHECK.
A &M CONSTRUCTION
SKH
REMODEL, FIRST 500 SF
101 -0000 -*42660
0
$132.99
$132.99
8/11/14
R668
11611
CHECK
A &M CONSTRUCTION
SKH
PC
Total Paid for REMODEL: $413.27 $413.27
Printed: Monday, August 11, 2014 10:37:37 AM 3 of 4 CRWSYSTEMS
DESCRIPTIO-
4A'CCO-, UN" f-�-
QTY r -AMOUNT PAID" PAID DATE :RECEIPT CHECK #
METHOD YPAIYBY"
LT)
BY,
SMI - RESIDENTIAL 101-0000-20308 0 $29.90 $29.90 8/11/14 R668 11611 CHECK A &M CONSTRUCTION SKH
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $29.90 $29.90
PARENT PROJECTS
Printed: Monday, August 11, 2014 10:37:37 AM 4 of 4 Cff?WSYSTEMS
Bin
'City of La Quinta
Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico .
.i.rQuaCA23.La 2- (760) 777-7012
Buildn .'Permit APliycaiion and- Tracking. Sheet
Permit #
Project Address: `�' c `aD C9 !3.. &TI
Owner''s Name: r L IXA D61,!5,
A. P. Number:
Address: • ^t `gam �� B��
Legal Description:
:City, St" Zip: LOR oC O� G L
Contractor: A��(/� [�l3�?.($ 1 �>�j i ��
i:;;ly>•Y:4�iiui:}li.j4
Telephone: � _O •.574t
+::ii �ti'�>:'I':D:fk •iii': {:: i}L.:,vL.iryy; ...
;i:.4ii:ii.L 4F<:
Address: zgCiZl% hta-e.
Project Description:
City, ST, Zip:' �✓ ! G �ZZ��
U�'h d ��
Telephone:J/,,o 77 4'9
State Lic. # :
City Lie. #.
Arch., Engr., Designer: LA -A [••{-
Address:
City., ST, Zip:.✓(p��{}(/7iZ
Telephone (� � $ lD 77
.::.:...:..::...... .
<• . ' " ' '.. .:.:: ..:<....
i{i�ji:i:��:r �iit:viv •'i
~:`:'?:`:'•.:<.:,.>::..:;:;>::;::•:
.:>.;:;.;.:<,;.:�:.:.:.::...:..,,;.;:.;.;•;;;;;;,;;,,
'Construction Type: Occupancy:
State Lic. #:
. i t
,,�Projecf type (circle one): New Add'n Alter Repair Demo
Name of.Contact Person: '0011(.~111 57
Sq. Ft.: 225Y •`
`# Stories:
# Units:
Telephone #"of Contact Person: 7,1e f> 77,,f
Estimated Value of Project:
APPLICANT: DO_NOTRWRITI -BELOW THIS. LINE
It
Submittal
Req'd
Recd
"TRACKING
PERMIT FEES.
2—
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
2—Title
24 Calcs.
;'
Plans picked up
b • t
: Construction
Flood plain plan
Plans,resubmitted 5V.
'
Mechanical .
Grading plan
2°" Review, read 0orcorrections/ss a
Electrical
Subcontactor List
Called Contact,Perso
.Plumbing
Grant Deed
Plans picked up
` �.,
S.M.I. ,
H.O.A. Approval
-Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready, for .correctio (issue
Developer Impact Fee
Planning Approval
Called,Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE o���sc�o
DesertSands:Unifed School District
47950 Dune Palms Road BERMUDA DUNES
RANCHO MIRAGE'V
Date 7/29/14 La Quetta; CA 92253 INDIAN WELLS
PALM DESERT
No. 32216 (760) 771 8515 - �QiN ioTirjy
.Owner Kim Davis APN # 773-052-.007 & 008
Address 51180 Avenida Obregon. Jurisdiction La Quinta
city.. La Quinta Zip Permit #
Tract # No. .of Units 1
Type. Residential Addition .
Lot # No. Street S.F. Lot#: No.: :Street S.F.
Unit 1 .5118o Avenida Obregon 393 Unit 6
Unit2 . Unit 7.
.Unit 3 Unit.8
Unit 4 Unit 9 . .
Unit 5 Unit:10. .
Comments
At the present time, the Desert Sands Unified School District does not collect fees on gar ages/carports,.:cove red patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces .that do -not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owneris exempt from paying school fees at this time:due to the following reason:
EXEMPT
This certifies that school facility fees imposed.pursuant:to
Education Code Section 17.620 and -Government Code 65995 Et Seq.
in the amount of $0.00 X 393 S: F: or ,$0.00 Have been paid'for. the property listed' above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
.Fees Paid By Exempt -Rick Morris. Check No.
Bank'Name/Recipient of Certificate Telephone: 7760-774-8225
.....
Funding Exempt
By Dr.. Gary Rutherford
Superintendent
Fee collected lexem e b $ G. ey Payment Recd
07er/Unc!4 _
Signature -
NOTICE: Pursuant to Government Code section 66020(d)(1), this will serve:to-notifyyou.that the 90 -day approval period in which. you may protest the fees
or other payment identified above will begin to run from the -date ori whichi'We'building orinstallation permit for project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorised to.collect,them on the'District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID.without embossed "seal
Embossed. Original -.Building Department_ Applicant. Copy.- Applicant/Receipt.. Copy -:Accounting
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Davis Residence
51-180 Ave. Obergon
La Quinta, CA
Project Designer:
Lench Design Studio
78215 Calle Cadiz
La Quinta, Ca 92253
760-564-1860
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
R"FlTEME ur--t
JUL 18 2014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Job Number:
Date: .� Q�
7/16/2014 p �c�'�7-�. ��
F pR CTS 0
The Ener Pro computer program has been used to perform the calculations summarized in ihisgeom e e ort. Thi ro rw a roval
9Y P P 9 P w ,� y�
P� P RP 9 �, PP
authorized by the California Energy Commission for use with both the Residential and Nonresidenti ;►ding E ergy Efficiency Standf
This program developed by EnergySoft, LLC — www.energysoft.co
8
EnergyPro 5.1 by EnergySoft User Number., 2655 RunCode: 2014-07-16T13:59:47 ID: _,
is
TABL2E'OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory, Measures Summary 10
HVAC System Heating and Cooling:Loads.,`Summary 13
Op
rA
CONS VE -FI)
EnergyPro 5.1 by EnergySofl Job Number: ID: LV� User Number: 2655
gy
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Davis Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
7/16/2014
Project Address
51-180 Ave. Obergon La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,986
Addition
393
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 2,593 Perim = 253' Existing
Wall Wood Framed
R-11 942 Existing
Roof Wood Framed Attic
R-19 2,593 Existing
Slab Unheated Slab -on -Grade
None 393 Perim = 15' New
Wall Wood Framed
R-13 626 New
Roof Wood Framed Attic
R-38 376 New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (W) 176.0 0.710
0.73 2.0 none Bug Screen Removed
Front (W) 40.0 0.710
0.73 2.0 none Bug Screen Existing
Front (W) 58.0 0.650
0.60 2.0 none Bug Screen New
Front (W) 144.0 0.650
0.60 10.0 none Bug Screen New
Left (N) 80.0 0.710
0.73 2.0 none Bug Screen Removed
Left (N) 96.0 0.650
0.60 2.0 none Bug Screen New
Rear (E) 164.0 0.650
0.60 2.0 none Bug Screen New
Rear (E) 30.0 0.710
0.73 2.0 none Bug Screen New
Skylight 17.0 0.710
0.73 none none None New
Rear (E) 60.0 0.710
0.73 2.0 none Bug Screen Removed
Right (S) 30.0 0.650
0.60 2.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
Zone 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING �{ ��
Qt Type OF
Gallons Min. Eff DistributioRUl�n)h,,� LA (PS,ta_ :use,,
111 A I
T I
SATE v rUry
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 201407-16T13:59:47i`I1?:
Pa e 3 of 14
�l
PERFORMANCE CERTIFICATE:: -Residential... Part 2 of 5 CF -1 R
Project Name
Davis Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi,Faniily ® Existing+ Addition/Alteration
Date
7/16/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section'require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Existing HVAC includes credit fora 11.4 EER Condenser. A certified HERS rater must field verify the installation of the correct
Condenser.
The HVAC System Living Zone incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Zone 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Zone 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
BU1LQln
1111or�-.
DEPT
1 -UR CO , "%_ tai ISD _
Ene Pro 5.1 by Ener Soft User Number., 2655 Run Code: 201407-16713:59:47 I IID;, Ti P of 14
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Davis Residence
❑ Multi Family 10 Existing+ Addition/Alteration
7/16/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2 r
Space Heating 7.88 6.46 1.42
Space Cooling 84.72 83.97 0.75
Fans 20.50 20.92 -0.42
Domestic Hot Water 18.79 18.79 0.00
Pumps 0.00 0.00 0.00
Totals 131.89 130.14 1.75
Percent Better Than Standard: 1.3%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (tM 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (M 560 242
Fuel Available at Site: Natural Gas (N) 350 96
Raised Floor Area: 0 (E) 870 194
Slab on Grade Area: 2.986 (S) 350 30
Average Ceiling Height: 8.9 Roof 2,986 17
Fenestration Average U -Factor: 0.66 TOTAL: 579
Average SHGC: 0.62 Fenestration/CFA Ratio: 19.4
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
7 16/2014
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Sin Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
'�-��
Company Lench Design Studio /% Ifii
Address 78215 Calle Cadiz Name i� ,f _.. n
�l.0 �C�f-it Bv1�r'P, 7-A
G'.d
City/State/Zip La Quinta, Ca 92253 Phone 760-564-1860 `� �I " 1 V
Sign + License # DEFDa e
J
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2014-07-16713:59:47 I OAVD: • "Pa e 5 ofP4
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Davis Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
1711612014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
1,297
0.730 None
0 180 Existing 4.4.7-A1
Existing Living
Wall
118
0.110 R-11
270 90 Existing 4.3.1-A2
Existing Living
Wall
254
0.110 R-11
0 90 Existing 4.3.1-A2
Existing Living
Roof
1,297
0.049_R-19
270 0 Existing 4.2.1-A4
Existing Living
Wall
270
0.110 R-11
90 90 Removec 4.3.1-A2
Existing Living
Slab
393
0.730 None
0 180 New 4.4.7-A1
Addition
Wall
200
0.102 R-13
270 90 New 4.3.1-A3
Addition
Wall
206
0.102 R-13
90 90 New 4.3.1-A3
Addition
Roof
376
0.025 R-38
270 0 New 4.2.1-A21
Addition
Wall
220
0.102 R-13
90 90 New 4.3.1-A3
Addition
Slab
1,296
0.730 None
0 180 Existing 4.4.7-A1
Zone 2
Wall
250
0.110 R-11
90 90 Existing 4.3.1-A2
Zone 2
Wall
320
0.110 R-11
180 90 Existing 4.3.1-A2
Zone 2
Roof
1,296
0.049 R-19
2701 0 Existing 4.2.1-A4
Zone 2
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status Glazing Type
Location/Comments
1
Window
40.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing Living
2
Window
16.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing Living
3
Window
20.0 0.710 Default
0.73 Default
270 Existing Double Metal Clear
Existing Living
4
Window
40.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing Living
5
Window
40.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing Living
6
Window
40.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing Living
7
Window
40.0 0.650 NFRC
0.60 NFRC
270 New IWC 6200 /Low -E
Existing Living
8
Window
18.0 0.650 NFRC
0.60 NFRC
270 New IWC 6200 /Low -E
Existing Living
9
Window
20.0 0.710 Default
0.73 Default
270 Existing Double Metal Clear
Existing Living
10
Window
48.0 0.650 NFRC
0.60 NFRC
270 New IWC 6200 /Low -E
Existing Living
11
Window
48.0 0.650 NFRC
0.60 NFRC
270 New IWC 6200 /Low -E
Existing Living
12
Window
48.0 0.650 NFRC
0.60 NFRC
270 New IWC 6200 /Low -E
Existing Living
13
Window
40.0 0.710 Default
0.73 Default
0 Removed Double Metal Clear
Existing Living
14
Window
40.0 0.710 Default
0.73 Default
0 Removed Double Metal Clear
Existing Living
15
Window
48.0 0.650 NFRC
0.60 NFRC
0 New IWC 6200 /Low -E
Existing Living
16
Window
48.0 0.650 NFRC
0.60 NFRC
0 New IWC 6200 /Low -E
Existing Living
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
6.8 6.0
2.0 0.1 2.0 2.0
2
Bug Screen
0.76
4.0 16.0
2.0 0.1 2.0 2.0
3
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0
4
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0
5
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0
6
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0
7
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0
8
Bug Screen
0.76
6.0 3.0
2.0 0.1 2.0 2.0
9
Buo Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0
10
Bug Screen
0.76
8.0 3.0
10.0 0.1 10.0 10.0
11
Bug Screen
0.76
8.0 3.0
10.0 0.1 10.0 10.0
12
Bug Screen
0.76
8.01 3.0
10.0 0.1 10.0 10.0
13
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0 1
14
Bug Screen
0.76
4.0 5.0
2.0 0.1 2.0 2.0 f L)UILU�
(� p �, , _."r �'1IV !i
15
Bug Screen
1 0.76
8.0 3.0
2.0 0.1 2.01 2.0 �� o -v
�, "' �C f YI nt~DT
16
JBug Screen
1 0.76
8.0 3.0
2.0 0.1 2.01 2.0 1 �`-
toy k ,7q--1,
IrUR
CONSTFgUUCTION
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2014-07-16713:59:47 tl ID Tr
Page 6 of 14
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Davis Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/16/2014
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC2
Azm Status Glazing Type
Location/Comments
17
Window 12.0
0.650 1 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Addition
18
Window 30.0
0.710 Default
0.73 Default
90 New Double Metal Clear
Addition
19
Window 12.0
0.650 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Addition
20
Skylight 17.0
0.710 Default
0.73 Default
270 New Double Metal Clear
Addition
21
Window 15.0
0.710 Default
0.73 Default
90 Removed Double Metal Clear
Zone 2
22
Window 20.0
0.710 Default
0.73 Default
90 Removed Double Metal Clear
Zone 2
23
Window 9.0
0.710 Default
0.73 Default
90 Removed Double Metal Clear
Zone 2
24
Window 16.0
0.710 Default
0.73 Default
90 Removed Double Metal Clear
Zone 2
25
Window 12.0
0.650 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Zone 2
26
Window 12.0
0.650 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Zone 2
27
Window 48.0
0.650 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Zone 2
28
Window 18.0
0.650 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Zone 2
29
Window 20.0
0.650 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Zone 2
30
Window 30.01
0.650 1 NFRC
0.60 NFRC
90 New IWC 6200 /Low -E
Zone 2
31
Window 18.01
0.650 1 NFRC
0.60 NFRC
180 New IWC 6200 /Low -E
Zone 2
32
Window 4.01
0.650 1 NFRC
0.60 NFRC
180 New IWC 6200 /Low -E
Zone 2
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Holt Wd
Ove hanq Left Fin Ri ht Fin
Len Hclt LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
2.0 4.0
2.0 0.1 2.0 2.0
18
Bug Screen
0.76
5.0 6.0
2.0 0.1 2.0 2.0
19
Bug Screen
0.76
2.0 4.0
2.0 0.1 2.0 2.0
20
None
1.00
21
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
22
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
23
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
24
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
25
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
26
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
27
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
28
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
29
Bug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
30
Bug Screen
0.76
6.0 5.0
2.0 0.1 2.0 2.0 U 1NG' R. In „ I V I A
31
JBug Screen
0.76
3.0 5.0
2.0 0.1 2.0 2.0
A 1 `nr= 1 r Cn�
32
JBug Screen
0.76
3.0 5.0
2.0 0.1 2.01 2.0
R s,r--- r
r(
_
vH CONS- Ffq V IZLJ
OCION
Ener Pro 5.1 by Ener Soft
User Number., 2655 RunCode: 2014-07-16T13:59:47 1 uFID:G
Page 7 of 1
CERTIFICATE OF COMPLIANCE:-. Residential, _
(Part 4 of 5) CF -1 R
Project Name
Davis Residence
Building.Type m Single Family
❑ Multi Family
❑ Addition Alone
m Existing+ Addition/Alteration
Date
7/16/2014
OPAQUE SURFACE DETAILS
Surface U- Insulation
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status
Joint Appendix
4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments
33 Window 4.0 0.650 NFRC 0.60 NFRC 180 New IWC 6200 /Low -E Zone 2
34 Window 4.0 0.650 NFRC 0.60 NFRC 180 New IWC 6200 /Low -E Zone 2
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang
ID Exterior Shade Type SHGC H t Wd Len Hat LExt RExt
Left Fin Right Fin
Dist Len H t Dist Len H t
33 Bug Screen 0.76 3.01 5.0 2.0 0.1 2.0 2.0
34 Bug Screen 0.76 3.0 5.0 2.0 0.1 2.0 2.0
LA C.) Iflo--n
/-Ar-t-(JVED
FOR CONSTRI I(ITtnn,
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2014-07-16713:59:47
II ID: Pa'e 8 of 141
DATE �_ BY
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R
Project Name
Davis Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1711612014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
Living Zone Existing Living
1,297 12,970 1981
Addition
393 3,144
Zone 2 Zone 2
1,296 10,368 1984
Totals 393 2,593 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone 1 Central Furnace
78% AFUE Split Air Conditioner 13.0 SEER Setback Existing
Zone 2 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback New
HVAC DISTRIBUTION
System Name Heating
Duct Ducts
Cooling Duct Location R -Value Tested? Status
Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 m Existing
Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New
El
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
No Pipe Insulation
40,000
50
0.53
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
o
6
Q751
—
J '�--�
System Name,(-,-
Pip
Length --Diameter
Pipe
Insul.
Thick.
Qty. HP
Plenum Outside Buried
❑
J 1 °
Y UF
I A! n.
---
❑
J
'f L0m'7
Ener Pro 5.1 b Ene Soft User Number: 2655
RunCode: 2014-07-16713:59:47 I IgAT Page 9 of 14
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
Davis Residence
1 7/16/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture a ui ment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant -or is enclosed.entirely in
conditioned space. ,I U 1-Y I -) F— 1
§150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Ge6'ficafi9n�6or oration. QUINTA
QMr_L iY DEPT.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2014-07-16713:59:47 jf /D: fv6TR 11C Page I0 of 14
DATE
�� BY
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Davis Residence
7/16/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause de radation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating S stems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Liglhfing LightingMeasures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150 k 2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7:
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
Vo 1� OF
BUILD/fv 90/NTA
G &
y 8FtFETY
P DEPT
�� i �, _ 7
EnergyPro 5.1 byEnergySoft User Number. 2655 RunCode: 2014-07-16T13:59:47 ID: vuuNS rni -,.`A!Pa"ge 11 of 14
DATE
_ By
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Davis Residence 7
7/16/2014
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131 134 and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
97-YOF L,q � �l�r
BUILDING a�►Ti�
& c,;, _
�, �r `7^y
_DEPT.
FSR COS
31�
EnergyPro 5.1 by EnergySoff User Number: 2655 RunCode: 2014-07-16713:59:47 ID: 'Page 12 of 14 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Davis Residence
Date
7/16/2014
System Name
Living Zone
Floor Area
1,690
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,040
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
70,000
33,196
2,055 599
30,292
Total Output Btuh
70,000
0
Output Btuh/s ft
41.4
2,815
2,152
Cooling System
0
0
Output per System
58,000
0
0 0
0
Total Output Btuh
58,000
0
2,055
0
Total Output Tons
4.8
1 2,815
2,152
Total Output Btuh/s ft
34.3
Total Output s ft/Ton
349.7
1 38,826
34,597
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
1,300
Existing HVAC 47,009 0
70,000
Airflow cfm/s ft
0.77
Airflow cfm/Ton
269.0
Outside Air %
0.0%
Total Adjusted System Output 47,009 0
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK Aug 3 PM
70,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
I Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
68 OF
68 OF 119 OF 119 OF
G
Heating Coil Supply Fan
117 IF
1,300 cfm
ROOM �p
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
80 / 59 OF
80/59°F 46/44°F 46/44°F
c
Cooling Coil Supply Fan 48 / 45 IF
1,300 cfm
29(8"% I< 'QOM --`
BUILDING*& 'M.5984F'N7
SAFEITY DEP
1 '-U" CUNSTR► ► ��® .
EnergyPro5.1 byEnergySoff
User Number: 2655 RunCode:2014-07-16713:59:47 IDJ Page 1 &'14
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Davis Residence
Date
7/16/2014
System Name
Zone 2
Floor Area
1,296
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,061
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 53,000
21,557
1,335 386
14,991
Total Output Btuh 53,000
0
Output Btuh/s ft 40.9
1,244
737
Cooling System
0
0
Output per System 34,000
0
0 0
0
Total Output Btuh 34,000
0
1,335
0
Total Output Tons 2.8
1,244
737
Total Output Btuh/s ft 26.2
Total Output s ft/Ton 457.4
24,046
16,464
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
1,300
Day & Night N4A336AKB
23,131
5,679
53,000
Airflow cfm/s ft
1.00
Airflow cfm/Ton
458.8
Outside Air %
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK
23,131
5,679
Aug 3 PM
53,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
I Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 67 OF
Outside Air
0 cfm Supply Fan
AL 1,300 cfm
67 OF
67 OF 105 OF
Heating Coil
-
104 OF
Roots
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/62°F 76/62°F 55/54°F
c
Outside Air ArC
0 cfm Supply Fan Cooling Coil
1,300 cfm
7s/sz°F
I 1 1
�1 IR
56 ! 54 OF
472 % ROO
hal' ' I,
BUILDING & SAF®®�62yFDEP,
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoR User Number: 2655 RunCode: 2014-07-16713:59:47
ID:j
Page 14 of 14