Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-4418 (SFD)
P..O:. BOX 1504-- 78-495 CA` LLE'TAMP:Ico rr LA QUINTA .CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT ,..•�y. (760).777-7012 FAX (7:60') 777-7011 INSP.ECTIO.N'RE.QUESTS'(:760) 777-7153 BUILDING PERMIT r Application`Number 04'0000"4418 .' Date 6/01/04 Property Address.'. '51`10 AVENIDA OBREGON APN: 773-215 006-6 - 0 0 n Application de`sc•ript.ion DWE°LL'ING -; SINGL A :Property Zoning . -.. :COVE.: RESIDENTIAL Application. valuation .. 97506 62004 Owner Contractor,' CITY OFLA®UINTA \ =---=-----.---------- ----¢IdAKEDEPT--c, CORONEL ENTERPRISES INC CORONEL CONSTRUCTION P O' BOX 389 P.O.:`: BOX 389 • LA QupI ,TA CA 92253 : :. LA QUINTA ' CA. '9.2253 ,:.. (76 0 ); " 5 64 -4 60 4 a WCC:. STATE FUND - WQ*:: 1744453 01/01/05 CSLB:.' 634981 01/31/06 CCC.: B;, 'C13 -------------- =----=---=--''yStructure`.Informat:on ,-------------------- -- `Construction.Type TYPE ;U, - N.ON,•RATED , Occupancy Type 'nWELLG/LODGING/GONG <=10 Flood Zone . . . . . NON -AO FLOOD'ZONE Other struct. info .. •` CODE `EDITION' 2001 CBC # ; BEDROOMS : <. 3.00 FTRE` SPRINKLERS. NO GARAGE SQ, :FTG 467.00 . r, 'PATIO, ,:SQ F.T,G 50.00 NUMBER ^OF'UN'ITS 1.00 :FIRST;'FLOOR Sa FTGj, 1533.00 - - - - ' -- - Permit BUILDING - -.- - - - -, - - - - - - - - - q - - -.- - - - -- -- - - - - - - - - - - - - - PERMIT Additional desc s. Permit Fee . . . 630.50 Plan Check Fee 102.46 Issue Date' Va1'4at i on 97506 Qty 'Unit Charge Per,:. Extension BASE FEE' 414.50 48.00 4.5000 THOU. BLDG 50,001-100,00.0.., 216.00 Permit. MECHANICAL Additional desc - Permit Fee 52.50 Plari.Check Fee 13.13 Issue Date:_ Valuat-ion 0 y Qty Uait_Charge ` Per .'` - Extension r -- P.O. Box 1504 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: �.• 'y'�/� Applicant: Applicant's Mailing Address: Architect or Engineer: I• VOICE (760) 777-7012 FAX (760) 777-701 1 INSPECTIONS (760) 777-7153 Date: 4 - / I& Arcrinect or Engineer's Address: Lic. No.. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class -V-, - ---_ _ _A'-1 I Date I hereby affirm under penaltyof OWNER -BUILDER DECLARATION perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division.3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sate. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. . BA P.C. for this reason Date • Owner WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is c sue workers' compensation insurance carrier and policy num r are: Carrier _S Polity Number \l- %4 t�. _ I certify that, in the performance of the work for which this rmZ is issued. I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I o become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with tho ovisions. Date_ —2—ZL Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I herebyaffirm under CONSTRUCTION LENDING AGENCY penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address IMPORTANT APPLICANT ACKNOWLEDGEMENT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of Le Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. , Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit or cessation of work for 18Q days will subject permit to cancellation. I certify that I have read this applicatiori and state that the above information is correct construction, and hereby authorize representatives of this co n to a ter upori a g ntion dmpropertywroth all icityns and county ordinances and state laws rotating to building for insand purposes. Date Signature (Applicant or Agent): Page 2 Application Number 04-00004'418: Date 6/01/04 Qty Unit. Charge Per: Extension : BASE.. FEE 15 , 00 1.00 9.0000 EA MECH.FURNACE <=100K 9.00 1.00 9..0000 EA ME'CH B/C, <=3HP/10'0K BTU 9.00 2.00 6.5000. EA MECH VENT FAN 13.00 1.00 6..5000 EA MECH EXHAUST HOOD. 6.50 .Permit . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 93.00_. Plan Check Fee 23.25 Issue. Date . . . . -Valuation 0 Qty,. .,Unit Charge Per Extension BASE.FEE 15.00 1533.00 .0350 'ELEC'NEW RE&_ -.1 OR 2' -FAMILY 53.66 467:'00 .0200 ELEC GARAGE OR� NON-RESIDENTIAL 9.34 1.00' 15 ..0'000 _ EA ELEC-, TEMPORARY POWER: POLE 15.00 Permit . . . PLUMBING Additional desc Permit Fee 123.00 Plan Check Fee 3.0.75 Issue Date :Valuation . . . . 0 Qty .'Unit"Charge Per Extension BASE FEE 15.00 9.00 6.:0:000 EA PLB FIXTURE 54.00 1.00 1.5:0000 EA PLB,BUILDING SEWER 15.00 1.00 7 . 500:0-- EA PLB 'WATER 'HEATER / VENT 7.50 1.00 .3 0000 EA PLB.WATER INST/ALT/REP 3.00 1.00 9'.00`o0 EA PLB.LAWN'SPRINKLER SYSTEM 9.00 6.0.0 .750.0 EA PLB'GAS PIPE >=5 4.50 1.00 15:0 0,0 0 EA PLB ; GAS'. METER 15.00 Permit GRADING 'PERMIT Additional desc_. Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation 0 Qty Unit Charge Per: Extension BASE FEE 15.00 Special Notes.and..c mments 1533 S.F. SFD'PERMIT.DOES NOT .INCLUDE`. t Page 3 Application Number" .04-00004418 Date 6/01/04 Special Notes and Comments.,.: BLOCK WALL,-POOL/SPA OR' DRIVEWAY APPROACH..'75% REDUCED PLAN CHECK FEE FOR MULTIPLE PLANS.OF SAME .TYPE: Other Fee's ART IN -PUBLIC PLACES -RES .00 DIF.COMMUNITY CENTERS=RES 97.00 DIF.:CIVIC CENTER`- RES 366.00 ENERGY REVIEW FEE`. 40.98 DIF''FIRE--- 97.00 "GRADING PLAN: -CHECK FEE .00 DIF LIBRARIES =.RES. 225.00 DIF PARK MAIN.T FAC - RES 5.00 'DIT'PARKS'/,REC - RES 502.00 COVE :PRECISE'PLAN.FEE 100.00 STRONG. MOTION (SMI-)- RES 9.75 DIF STREET�MAINT'FAC=RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due .Permit Fee Total 914:00 .00 .00 914.00 Plan Check Total 169-.59 .00,1- .00 169.59, Other Fee Total 255:5.73 00 .00 2555.73 Grand Total '' - .3639:3.2 .00 .00 ( 1 3639.32 Unit 1 52110 Avenida Obregon Unit 2 Unit 3 Unit 4 Unit 5 Comments 1533 Unit 6' Unit 7 Unit 8 'Unit 9 Unit 10 At the present time, the Desert Sands Unified School.Distrid does not collect fees on garages/carports,,covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living; sleeping; cooking; eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying'school fees,at this time due to:the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 177620 and Government Code '65995,Et Seq. in the amount of $2.24 X 1,533 S.F. or $3,433.92 have been,paid for the property listed. above and that building permits and/or Certificates of Occupancy for this squar&footage in -this proposed project may now be issued. Fees Paid By CC -Valley Independent Bank-Ish Coronel Check No:, 310911 Name on the check Telephone 564-4604 Funding- Residential By Dr. Doris Wilson Superintendent Fee collected /exemptedby Beth SChieferstine . Payment Recd $3,433.92 Over/Under Signature ILIVA, NOTICE: Pursuant to Government Code Section 6020(d)(1),:this will serve to'notify you that,the 90 -day, approval period in which you may protest the fees or other payment identified above wiil begin to run from the date on,which th6 building or installation pennitfor this project.": issued 6f,.' rom the date on which those amounts are paid to the District(s) or to another public entity authorized to collectdhem on.the District('s) behalf; whicheveras earlier. NOTICE: This Document NOTiNALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting CERTIFICATE OF COMPLIANCE; Desert Sands Uhifled School District O r ., x ;.r' 47950. Dune Palms. Road 4 QBERMUDA DUNES r Date 7/26/04 La Quints, CA'92253 RANCHO MIRAGE No. 26218 (760) 771-8515 � INDIAN WELLS �,� P LAQ� NTS y QINDIO O Owner Coronel Enterprises,,; Inc.APNV 773-215-006 Address 'Jurisdiction La Quinta City Zip Permit .# Tract # IStudy Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot;# No. Street S.F. Unit 1 52110 Avenida Obregon Unit 2 Unit 3 Unit 4 Unit 5 Comments 1533 Unit 6' Unit 7 Unit 8 'Unit 9 Unit 10 At the present time, the Desert Sands Unified School.Distrid does not collect fees on garages/carports,,covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living; sleeping; cooking; eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying'school fees,at this time due to:the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 177620 and Government Code '65995,Et Seq. in the amount of $2.24 X 1,533 S.F. or $3,433.92 have been,paid for the property listed. above and that building permits and/or Certificates of Occupancy for this squar&footage in -this proposed project may now be issued. Fees Paid By CC -Valley Independent Bank-Ish Coronel Check No:, 310911 Name on the check Telephone 564-4604 Funding- Residential By Dr. Doris Wilson Superintendent Fee collected /exemptedby Beth SChieferstine . Payment Recd $3,433.92 Over/Under Signature ILIVA, NOTICE: Pursuant to Government Code Section 6020(d)(1),:this will serve to'notify you that,the 90 -day, approval period in which you may protest the fees or other payment identified above wiil begin to run from the date on,which th6 building or installation pennitfor this project.": issued 6f,.' rom the date on which those amounts are paid to the District(s) or to another public entity authorized to collectdhem on.the District('s) behalf; whicheveras earlier. NOTICE: This Document NOTiNALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting E/e-v P.O. BOX 1504 APPLICATION ONLY Building '� i /� 78-495 CALLE TAMPICO. Address c�L' \ V O�r �. ,.� LA QUINTA, CALIFORNIA 92253 Owner Mailing Address City Zip Tel. M State Lic. City & Classif. �� i �` Li c. # Arch., Engr., Designer Address Tel. City IZip -:ILi t# I hereby of m that I am "cans :.d un er rovlsions of Chapter 9 ommencIng with Section 7000) of Div i �h\ inns an Pr fessions Code, and, my license i � I�r�e and effect G OWNER -BUILDER DECLAR TIo1 ON I her by affirm at I am exempt from the Contracto s� tcerise Law for the following. reason: ( 1.5.8usiness and Professions Code: -.Any city or county which requires e permit to construct, atter, improve, demolish, or repair any structure, .prior to Its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter .9 (commencing with Section 7000). of Division 3 of the Business and Professions Code, or that. he,isexempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any -applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I:I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an. owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended.or.offered for sale. It, however, the building or improvement is sold within one year of completion;` -the owner -builder will have the' burden of proving that he did not build orimprove for the purpose of sale.) 1 1 I, as owner of the property, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: -The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a confractor(s) licensed pursuant to the Contractor's License Law.) fi 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to sell -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company fl Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less./ I certify that in the performance of thg work.for which this permit is issued, I shall not employ any person in any manner so as to become,subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION. LENDING AGENCY 1hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information Is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above• mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip LDING: TYPE'CONST. OC/C. GRP. . Number' -1-T-1- 2A S --(, io -F. Project Description � • '� = Sq. iz Stories Ft. i G 1 Size ` J Stories New 9f Add ❑ Alter❑ stimated Valuation PERMIT Plan Ch k. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL . REMARKS No. Dw. Repair ❑ ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: } Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE .,,main•, __,_...,. t 1 Demolition ❑ OUNT JUN -01-2004 TUE 02.01 PM • . May -12-04 01:13am From- Coronel Construction RECORDING.REQUESTED BY: Fldellty Natlonal,Title CompanY Escrow No., 6228 -KC T11A.6rder No. 1446034 When Recorded Mail Document and Tex Statemant To: Zeke Coronal P0, BOX 369 La Qulnte; CA 92253 Sz -/l0 A✓,� °} oma: FAX No -.760 564 4202 T-340 P. 002 P.001/002 F-171 lFY TWIN!' oRIGINAL 4 R ,O�iH AND : &ALItTLe —79PACE ABOVE THIS LINE FOA The undersigned grantdr(s)dtclare(s) Dodumentary transfer taxis' 3183.70 [ X I computed on fullvalue-of property eoh;jeyed,,o► j I computed on full value less value of`iiens.,of encumbrandeto remaining et'Alme"Of 6818, ( 1 Unincorporated Area Cixy of La Quints E FOR A VAL'UA8l.E'CONSII]ERATIAN, reoeipt o#-vuhlch is"here by acknowledged, Victor E. Anderson, Jr. and Katherine J. Anderson, Huebiind and Wife as Joint Tenants hereby GRANTIS) to Goronel Enzerprlsos, Inc.;,=a California Corpoi bion the followlhg described :real property In: the CItV of Lei Quinta County of Riverside', State of Uifornia: SEE EXHIBIT ONE ATTACHED HERETO AND MADE A -PART HEREOF DATED: April 30,� 2004 STATE OF CALIFORNIA .COUNTY. OF. D rC - ON - ' before me; Victor E. Andersen; Jr:� .`� C61? Qb�sc ALog personally appeared , Katherlrlrl J An. a- proved to me on tha.basis. of sa#isfacto y avidence) to. be the perso.tti(s) chose._ name(s) are ubscrihed to the with+ in ument and r. CAR©i.YN t3OSWORTH. acknowI dged �o a tfllet they xecuted the U NOTAHYP ®LIC-CAUFORNIAD same In h sir. thorized cap. {I®s :andahat oraAkCi�couniTr 0 by thei s gnaeure(s) on; the instrument a COMM. E%P:.IUNE 9, zona 1 v personls), o he entity: upon baha)f of- which the person{s) acted, executed the instrument. Witness my d flci Slgnazure MAIL TAX'STATEMENTS AS' DIREtTtD ABOVE FO -213 (Rev 7196) GRANT DEED' . M'DISTRICT' PLANNING -.REVIEW. FORM, This form is. ;to be, used by;, CDD, staff for -review of single farhily 'dwellings-intNe RC -(Cove Residential) District per Section '81.50.096..of the :.Zoning .Qode.,Its purpose is -to determin-e. 1) that roposed h6beik 6 gdesign3does'not,. up 1.66te. the -same architectural* style -house . does , .." 2). , - n'-1 of any within.20.0 feet of the ap0lic6ntjand/6r,2):ff therd-is a need for lh'e' applicant, to file for'Mast6i r ap pant does need:toj ilo..a:'M6ster, Design Design Guidelines: If the applicant n. Guiddine, please transmit this 'ihfbrmation'to,thou Building '.'-and' Safety 'DOPartment as.. part of yo . ur correction -list.. Please attach additiona[ ! 001ahations as: necessary. APPLICANT: .SITE ADDRESS: APN- -7 IT CASE NO l LEGAL: LOT Ip BLOCK UNIT' &Q.@V1.6. CHECK AND APPROVED.BY: DATE;. Inform the assione'd Building.plain checker u'pon your Ossignmewn.t.to thin case. The CDD Executive'Secretary maintains -a log -book" to -track applications: pp Ications. a(,nd assign 'case numbers. REQUIRED ITEM Verify legal and, APN information Consistent w*ith MDG on file, (as applicable) .MDG filing required filings since .9/3/98) Architectural variety with -in 200 feet of the surrounding area: Architectural design feiatures Other Requirements: ek—# on NOV. 0.2 `2004 TUE 02:48 PM Co one I 'Cons t r uo-t i on ' FAX No, 160.564. 4202 P. 001 S CITY:OF LA'QUINTA oe , BU1..1=DING &SAFETY pEPARTMENT INSPECT 'REQ ' T LI s.- -7.15 ..,. . her— . er CORONEL ENT. I F • '`CORONER CONT •^ PermltNumber 04-4 18 v�I�aAtdDE.D 1� ' POSTON`J0B-fN C0 OU PLACE INSPI=CTOR'MUST SIGN ALL APPLICABLE SPACES :sa ffD AVE; OBREGON JOB ADDRESS : 153315 SFD YPERMIT DOES NOT INCLUDE Bi: WALLI POOL/SPA OR QRIVFWAY APPROACH: TYPt OF INSPECTION DATE . INSP. TEMPORARY POWER., do SETBACKS:::. ' ETBACKS ::'. ,...'" U/G PLUMBING=] WASTE' U/G. ELECTRICAL/ GROUNDING ., FOOTINGS:/ STEEL""• CONCRETE SLAB d, NOT•POUR CO ICRETE U TILABOVE SIGNED ROOF NAIL"/'PRE=ROOF = �- OKAY, TO WRAP': p .7 FRAMING; COMBINATION .dG ROUGH ELECTRIC :ROUGH. PLUMBING . ROUGHWECHANICAL INSULATION`'-. COVER NO WORK, UNTIL ABOVE SIGNED INTE=RIOR GYP. BD:; DRYWALL EXTERIOR LATH GAS TEST;;'1::. p SEPTIC ABANDONMENT SEWEFi;CONNECTfON SEPTIC /.GREASEINTERCEPTOR ' MASONIiY INSPECTIONS FOOTINGS./ STEEL , BOND BEAM '..:,POOL'/=:SPA % WATER FEATURE INSPECTIONS PRE-GUNITF-/-:SETBACKS U/G PLUM61NGFl ' U/G,'GAS: U/G ELECTRICAL PRE-PLASTER'` ALARMS! BARF IERS :FINAL: INSPECTIONS TEMP USE OF. PERMANENT POWER ELECTRIM ; PLUMBING.- MECHANICAL PUBLIC:WORKSIDEPARTMENT „% COMMUNITY pEVELOPMENTGEPT, FINALlJOBiCOMPLETED , ABOVE APPROVALS p.0 NOT INCLUDE RIGHT TO '.;'TURN ON UTILITIE3 OR OCCUPY BUILDING GO�O�E{.-52-(!C A�G.O I��Iu "NJ- -[J- Z1S-D®(o-L� ��-� C.,42, TITLE 24 REPORT Ater T OLC-o S>aVVrA 'F-E� Title 24 Report for: Coronel Enterprises Inc. Acapulco Santa Fe -All Orientations La Quinta, CA 92253 Project Designer: Stephen R. Nieto 78-120 Calle Estado Ste. 206 La Quinta, CA 92253 760-564-4707 Report Prepared By: Stephen R. Nieto South West Concepts 78120 Calle Estado, Suite La Quinta, CA 92253 (760) 564-4707 Job Number: 00112 Date: 5/18/2004 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT EC'O--I - BY �r The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. yPro 3.1 By EnergySoft This program developed by EnergySoft, LLC (415) 883-5900. Job Number. 00112 User Number. 5970 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 13 EnergyPro 3.1 By EnergySoft Job Number. 00112 User Number. 5970 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Coronel Enterprises Inc 5/18/2004 Project Title Date Acapulco Santa Fe -All Orientations La Quinta Project Address Building Permit# South West Concepts (760) 564-4707 Plan Check 1 Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,533 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,533 ft2 Building Type: Wood (check one or more) Exterior Wall © Single Family Detached ❑ Addition' ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Location/Comments TVDe U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade Na 0.756 Covered Slab w/R-0.0 Perimeter Insulation FFNFSTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shadin Yes / No Yes / No Front 40.0 0.55 0.53 Woven Sunscreen X❑ ❑ ❑ x❑ Front 12.0 0.57 0.55 Woven Sunscreen X❑ ❑ ❑ X❑ Left 32.0 0.87 0.70 Woven Sunscreen X❑ ❑ ❑ x❑ Left 4.0 0.72 0.73 Woven Sunscreen X❑ ❑ ❑ X❑ Rear 33.0 0.72 0.73 Bug ScreenX❑ ❑ ❑X❑ Rear 80.0 0.85 0.70 Bug ScreenX❑ ❑ ❑X❑ Rear 16.0 0.87 0.70 Bug Screen X❑ ❑ ❑ Right 4.0 0.57 0.55 Woven Sunscreen x❑ ❑ ❑ X❑ Right 20.0 0.60 0.53 Woven Sunscreen x ❑ ❑ X❑ ❑ ❑ ❑ ❑ El ❑❑ Run Initiation rime: 0511810409:18:42 Run Code: 1084897122 EnergyPro 3.1 By EneraySoft User Number. 5970 Job Number. 00112 Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Coronel Enterprises Inc 5/18/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments rPntral Furnarp 92% AFUE nur_.fs in Attic 42 Setback - Reg HVAC - Cooling Equipment Minimum Type (air conditioner, Efficiency heat pump, evap. cooling) (SEER) Duct Location (attic, etc.) Duct R -Value Thermostat Location / Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 S .tha .k Res HVAr WATER HEATING SYSTEMS Water Heater Water Heater System Name Type Distribution Type Rated 1 # in Input Syst. Btu/hr Tank Cap. (gal) Energy Fact! 1 External or Recovery Standby Tank Insul. Efficiency Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Standard 1 40.000 50 0.53 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btufhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Stephen R. Nieto Title/Firm: Stephen R. Nieto Title/Firm: South West Concepts Address: 78-120 Calle Estado Ste. 206 Address: 78120 Calle Estado, Suite 206 La Quinta, CA 92253 Telephone: 760-564-4707 Lic. #: 52 3 (signature) (date) Enforcement Agency Name: Title/Firm: _ Address: Telephone: La Quinta. CA 92253 Telephone: 760 564-4707 (signature) (date) IEnemvPro 3.1 By EnergvSoft User Number. 5970 Job Number. 00112 Pa0eA of 13 1 Certificate of Compliance: Residential (Addendum) CF -1 Coronel Enterprises Inc 5/18/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used With the performance approach. The local sL...:..•.a:A..�s. - ftnd mmu raiarf 7 h:lile ina nr dASinn that otherwise comolies O"YOrGemeOL 4UMMY 4aL01111111Qa Ulu away Ya.y — —• Jv.�..vw....••I `•••" •^•'J •-J------------� v based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System 'Res HVAC' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. An Air Retarding Wrap must be installed per the manufacturer's specifications that must comply with ASTM E1677-95. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -614-1 Plan Field The HVAC System 'Res HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 05/18/04 09:18:42 Run Code: 1084897122 EnergyPro 3.1 By EnergySoft User Number. 5970 Job Number. 00112 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§ 150(,): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. ! § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does 0 not apply to exterior mass walls). �'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent ®§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perminch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑X § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ Gas Logs. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. © §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. FV --1 § 150(i): Setback thermostat on all applicable heating and/or cooling systems. X] §1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (RA or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 5970 Job Number. 00112 Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. _ DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181. UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than seated sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non-ledrical cooking appliances with pilot < 150 Btu/hr) El§118 (f): Cool Roof material meet specified criteria Lighting Measures (� §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the altemative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. r- 3.1 By EnergySoft User Number. 5970 Job Number. 00112 Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R Coronel Enterprises Inc. Project Title Acapulco Santa Fe -All Orientations La Quinta Project Address South West Concepts X60) 564-4707 Documentation Author Telephone Computer Performance15 �.......u;nr Rkmhnd /Park2nn nr rmmnuterl - -- Clmat@ Zone Building Permk # Plan Check/Date Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 0.89 Facing North Margin LJ ❑ Facing East Margin Wall- 276 -0_059_ 0 90 Facing South Margin Facing West Mar in 0.33 0.56 0.69 0.19 1.11 -0.22 0.37 0.52 Space Cooling 33.66 34.07 -0.4 ❑ 31.90 1.76 Wall 142 0-059 180 90_ 26.30 7.37 34.07 -0.41 Domestic Hot Water 15.53 1 15.37 0.151 � 15.37 0.15 15.37 0.15 15.37 0.15. 1 49.77 __-0.311 47.97 2.11 42-76--7- M0 49.82 0.26 Totals 50.08 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 1,533 ft Building Type: Single Fam Detached Floor Construction Type: El Raised Floor Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 15.7% Number of Dwelling Units: 1.00 Total Conditioned Volume: 15,330 ft Number of Stories: 1 Total Conditioned Slab Area: 1,533 ft BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Res.HVAC-_ _ - 1,533 -X5,330 -t00_ Conditioned.- -...-Setback- -2 /a OPAQUE SURFACES Solar Act. Gains Tunas Area 11 -Vat O7m Tilt Y I N Form 3 Reference Location / Comments Boot_ 53.3 0_028 _ o -22 X LJ ❑ R--3&Roof-(R-3&2x14 ,.,;t Flnnr 7onp 1stEtoor_Zone Wall- 276 -0_059_ 0 90 R --13_W 11-WLL' EP -S _ .Doo -r--- 20 0_387- 9.0_ ❑ ❑ Snliri Wood Door Js Floor lone WaI1,w/_1" FPS---- Ist FlOOr70nP Wall 418 0.059 go 90 ❑ R-13 _ PS_ 7nne Wall 142 0-059 180 90_ RS3 Wall w/1" -1St.Ftonr - -Wall_ 332 -0_0.5.9_ 270 90_ ❑ � .R-13 Wall -w/1" EPS - 1st Floor_Zone - - ❑ ❑ a- -- -- - --- ❑ -- - -- -- - - El El -- El ❑ M- u- - ❑ ❑- _ _-- ❑ ❑ -_-- El - - ❑ ❑ - - - - ❑❑ - - - - - - u ❑ ----._._._._ -- -- -- - - _ -- ❑ u �_ Run Initiation Time _0 /31�1�4 Q9_1.8-:42 RunC -de: 1084897122 3.1 By EnergySoft User Number: 5970 00112 Page:B of 13 Computer Method Summary (Part 2 of 3) C -2R Coronel Enteryises Inc. _ _ _ 5/18/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window--E[ont (Nodh) X0.0_ 4 550_ -0_53_ __0_ ._-90. Double-NoriMa Tinted.Default- 1st FlooLZonP 2 Window Front (North) 12.0 0.570 0.55 0 90 Double NonMtl Tinted Default _1st Floor Zone 3 WindowLeft (East 16.0 0.870 0.70 90 90 Double Metal Clear Default 1st Floor Zone _ 4 Window Left 12.0 0.870 0.70 90 90 Double Metal Clear Default list Floor Zone 5 -(99 -Sit- Window Left (East) 4.0 0.720 _0.73 90 _ 90 Double Metal Clear Default ._ 1st Floor Zone 6 Window Left (East)_ 4.0 0.870 0.70 90 90 Double Metal Clear Default 15t Floor Zone Z Window Rear (South) 9.0 0.720 073 180 94 49uble Meta 1guJ)_efaWt__ 1stF1O0_r_Zone .- 8 Window Rear (South) 40.0 0.850 0.70 180 90 Double Metal Clear Default 1st Floor Zone _ Windov ___j3e (South) �2 U X7_20 0,73- tBSZ -9Q 491�I_e�letal_Ctea�eia_uJ� LE_o..oLZ2na JR Llllindow Rear (SoAW _ 40.0 _0•>35k _ 0.70 180 _ 90 Double Metal r Default 1&t Floor Zone Window Rear -(SQA J? Q X72(1 0 73 _180 90 Double Metal Clear Default _ 1st Floor Zone 12 Window Rear (South) 16.0 0.870 0.70 180 _ 90 Double Metal Clear Default _. 1st Floor one J3 Window Right .(West) 4.0 4.5.7.0 Q.SS -270_ 90. Double NonMtl nted_Default- _J.St_ Aw_Z0ne _ 14 Window Right (West) 4.0 0.600 0.53 _ 270 90 Double NonMtl Tinted Default _1st Floor Zone _. 15 Window Right (West) 16.0 0.600 0.53 270 90 Double NonMtl Tinted Default 1st Floor Zone - INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Woven Sunscreen 0.30 6.6 6.0 0.0 0.0 _ 0.0 0.0 _ 2 Woven Sunscreen 0.30 2.0 6.0 0.0 0.0 0.0 0.0 3 Woven Sunscreen 0.30 4.0 4.0 0.0 0.0 0.0 _ 0.0 4 Woven Sunscreen _ 0.30 3.0 4.0 0.0 0.0 0.0 0.0_,- 5 Woven Sunscreen 0.30 1.0 4.0 0_0 0.0 0_0 0.0 6 Woven Sunscreen 0.30 2.0 2. 0_0 -.10-0 0. __Q-0 7 Bug Screen_ 0.76 3.0 3.0 0.0 _ 0.0 0.0 0.0 8 Bug Screen 0.76 6.6 6.0 0.0 0.0 0.0 0.0 9 Bug Screen 0.76 2.0 6.0 0.0 0.0 0.0 0.0 10 Buq Screen 0.76 6.8 6.0 0.0 0.0 0.0 0.0 11 Bug Screen_ 0.76 2.0 0.0 0.0 0.0 0.0 12 _ Bug Screen 0.76 4.0 _6.0 4.0 0.0 0.0 0.0 0.0 _ 13 Woven Sunscreen 0.30 1.0 4.0 0.0_ 0.0 0.0 0.0 14 Woven Sunscreen 0.30 2.0 2.0 0.0 0.0 _0.0 15 _ Woven Sunscreen _ 0.30 4.0 4.0 ____0.0 0.0 0.0 0.0 0.0 3.1 By EnemySoft User Number. 5970 Job Number. 00112 Page:9 of 13 Comauter Method Summary (Part 3 of 3) C -2R Coronel Enterprises Inc. 5/18/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Frame VVall• Stucco_ �Z6. _0.33 —21 -O-4Z R13 WaILwL1 P_S _2 1siEloorZone./ sriot�ass — PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / Comments pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Cantral Fumace 92%AFUE Ducts in Attic 4.2 ____ Setback Res HVAC _ Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments SplitAir Conditioner 12.05 ER- Duds in Attic 4.2 Setback WATER HEATING SYSTEMS 1 Rated Tank 1 Energy Fact. 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less SmalwAs Standard ._ 1— 40 QQO- 50 0_53 nip _ 12 _ 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. FnernvPrn 3.1 Rv EnemvSnft User Number. 5970 Job Number. 00112 Paae:10 of 13 I Computer Method Summary (Addendum) C -2R Coronel Enterprises Inc 5/18/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local .A_._s:_ .I.....d........., s *k i—fifi— inn and may raiar_t a huildina or desian that otherwise complies BnTOfGeniena agen:.y ueuonnu:aa u:a aucyua.y — — J..�............... ....� ..._� ._�___ ________� _ based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System 'Res HVAC" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. An Air Retarding Wrap must be installed per the manufacturer's specifications that must comply with ASTM E1677-95. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. 2la:nj Field The HVAC System 'Res HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System 'Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 05118104 09:18.42 Run Code: 1084897122 EnergyPm 3.1 By EnergySoft User Number: 5970 Job Number. 00112 Page:11 of 13 [HVAC SYSTEM HEATING AND COOLING .LOADS SUMMARY DATE .PROJECT NAME Coronel Enterprises Inc. 004 SYSTEM NAME A AREA FLOOR AREA 1,533 Res HVAC ENGINEERING CHECKS Number of Systems I �I SYSTEM LOAD COIL COOLING PEAK __ COIL HTG. PEAK CFM Sensible Latent CFM�Sensible_ He_ ating System _ Output per System 37,000 Total Room Loads 0155 28,274 4551 514 19,14 Total Output (stun) 37,000 Return Vented Lighting 0 Output (Btuh/sgft) 24.11 Return Air Ducts 1,414 957 Cooling System Return Fan 0 0 Output per System 23,200 Ventilation F--'0 0 0 0 Total Output (Btuh) 23,200 Supply Fan 0 0 Total Output (Tons) 1.9 Supply Air Ducts 1,414 957 Total output (Btuh/sgft) 15.1 TOTAL SYSTEM LOAD 31,10 _ X55 ( 21,055 Total Output (sgft/Ton) 792.9 Air System — HVAC EQUIPMENT SELECTION CFM per System — 895 Airflow (cfm) 895 BDP CO.563AN024-A 18,479 975 37,000 — Airflow (cfm/sgft) 0.58 -- - - - Airflow (cfm/Ton) 462.9 Outside Air 0.0 - -- - Total Adjusted System Output 18,479 975 37,000 (%) (Adjusted for Peak Design Conditions) Outside Air (cfm/sgfl)_�__ 0.00 TIME OF SYSTEM PEAK I Aug 2 pm Jan 12 -am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.0 of 69.0 of 105.0 of Supply Air Ducts 01 Outside Air O 0 cfm 104.0 of Supply Fan Heating Coil ROOMS 895 cfm 70.0 of 69.0 OF I Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0 / 73.5 of 79.5 / 62.4 of 79.5 / 62.4 of 55.0/53.50 Supply Air Ducts Outside Air 0 0 cfm Supply Fan Cooling Coil 56.5 /54.1 F 895 cfm 40.0% R.H. I ROOMS 78.0/61.9°F 79.5/62.40F Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number. 5970 Job Number. 00112 Page: 12 of 13 ROOM LOAD SUMMARY PROJECT NAME Coronel Enterprises Inc. DATE 5/18/2004 SYSTEM NAME Res HVAC FLOOR AREA 1,533 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM I SENSIBLE LATENT CFM SENSIBLE 1stFloor Zone 1st Floor 1 1,155 28,274 -455 1155 28,274 -455 514 19,141 PAGE TOTAL 1 1,155 28,274 -455 514 19,141 TOTAL 1 1.155 28,274 -455 514 19,141 EnergyPro 31 By EnergySoft User Number. 5970 Job Number. 00112 Pagel3 of 13