Loading...
04-6078 (SFD)BUILDING & SAFETY DEPARTMENT P.O. Box 1.504 K41 (760).777-7012 OFT1 78-495 CALLS TAIVIPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number 04-00006078 Date 8/28/04 Property Address . . . . 52"530 AVENIDA OBREGON APN: 773:.-285-"002-1 -00.0000-. Application descript•ion.. �DWELLING�� SINGLE FAMILY DETACHED Property ;, Zoning ,. `• COVE'. RE;q,WENTIAL Application valuation . 11172'34 ' Owner Contractor ' MARK TUVELL, MTB INC. 50-855. WASHINGTON..ST, #149 ,508;55 WASHINGTON ST STE- 149 LA QUINTA. CA 92253 -LA QUINTA CA 92253 (760")_:272-60,44 WCC : : "S,T'AT�E FUND :.WCc 179'5095-2004 08/01/05 CSLB: 838'0,89 05/31/06 CCC B ------------.--- -==,:.--°=-- Structure Information =`---------------- --------- Construction Type TYPE V NON RATED. Occupancy Type . . . . DWELLG/LODGiNG/LONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info CbDE:EDITION` 2001 CBC. 3.00 FIRE - SPRINKLERS -NQ GARAGE SO.=; FTG t .i. 667.00 NUMBER: µOF UNITS't l..0 0 FIRS'T':.FLOQR, S`Qt 'FTG., 1821'.'0 0 t¢', Permit `BUILDING -PERMIT Additional desc Permit Fee �'` '702.S0,_, Plan' "•Chuck, -F'ee 114.16 Issue Date Valuation°" '` . 117234 Qty Unit Charge Per Extension BASE 'EEE .•.-63.9 . 50 18.00 3.5000 THOU BLDG !0G,001-500,000 63.00 ------- . - . - . - . - . - . ------------------ ------------------------ Permit MECHANICAL Additional descFP i Permit Fee 59 00 P1an4.-CheckFFee,,i "�6. 00 Issue Date ValuatioriJ.. b, 0 Qty Unit Charge P,er Extension BASE,: FEE . a � P.O. BOX 1504 • VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 0-4 46E?P%� � Date: Applicant: Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. 3 OO J� License Class 8License No.—g',3 S Date cy -2-2. -0 !1 Contractor /_ l -r%g -ii e . OWNER -BUILDER DECLARATION .I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (--) I, as owner of the property, am exclusively Contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (-,) I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. MYy�orkers' compensation insurance carrier and policy number are: Carrier 117-* f uAJD Policy Number / 7 °J x'09 S--ZaQV _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date Applicant tr 01 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any'permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comp) with all city and county ordinances and stale laws relating to building construction, and hereby authorize representatives of this county to enter u on the above-mentione for inspection purposes. Date / Signature (Applicant or Agent): G Page 2 Application Number....,-. 04-.00006,078 Date 8/28/04 Qty Unit: 'Charge -Per'.,_•. Extension 1.00 9-0000 EA MECH.FURNACE..<=100K . 9.00 1.00 9. 0000 'EA MEC'HC B/.0 <=3'HP/100K BTU 9.00 3:0.0.. 6.5000 EA` MECH VENT' FAN. 19.50 . 1.00 6.50;00 EA MECH EXHAUST HOOD 6.50 Permit . :... . . . . ELEC-NEW RESIDENTIAL Additional desc _. Permi-t. Fee 10,7'.08 Plan `Check Fee, 6.70. Issue Date :Vad dation 0 Qty Unit Charge Per Extension. -, BASE FEE. 15.'. 0'0 1821'.-0-0 ..:0350 ELEC NEW RES - 1 ;OR 2 FAMILY 63. 7..4 _. 667:'0.0 .0200 .. ELEC.GARAGE OR`'NON-RESi�DENTIAL 13.34 1.00 .15.0000 EA ELEC'TEMPORARY"`POWER.POLE 15.00 Permit . . . ... . .PLUMBING Additional desc Permit Fee 129.00 Plan Check Fee 8.06 Issue Date Valuation 0 Qty unit Charge Per Extension . BASE' FEE 15.00 10.00 6.0000''EA, PLB FIXTURE 60.00 1.00, 15, 0,000 --EA PLB.. BUILDING:. SEWER 15.00 1.00 1 7 ::50'0 0:: EA PLB WATER-,HEATER'/.VENT 7.50 1.00 3:00,0'0 EA PLB WATER.,INST%ALT/REP 3.00 1.00 9. 0000 -.EA PLB LAWN` SPRINKLER `SVTEM 9.00 6.00 .7500 EA PLB GAS' -Pfi`.PE >=5 4.50 1.00 15.0000 EA -PLB 'GAS METER 15.00 ---------------------------------------------------------------------------- Permit .GRADING PERMIT Additional desc Permit Fee 15.00 Plan. Check Fee .00 Issue Date Valuation, 0 Qty Unit Charge Per Extension BASE.FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1820 S.F. SFD PERMIT DOES- NOT INCLUDE Page 3 Application. Number '-.04-00;0.06.07°8 4 Date 8/28/04 Special Notes and°`Comments BLOCK WALL, POOL/'SPA , OR DRIVEWAY '- ': - APPROACH: 75%.- REDUCED: PLAN CHECK„ FEE' FOR MULTIPLE PLANS OF SAME ''TYPE Other Fees . . . . ART'``IN PUBLIC PLACES -RES' .00 DIF 'COMM UNITY... CENTERS -RES 97.00 DLF CIVI-CCENTER -r'RES 366.00 ENERGY REVIEW" FEE 11.42 `DI F.,FIRE `PROTEC;TION-RES 97.00 .. GRADING'' PLAN CHECK FEE 1.00 DIF'•.LIBRARIES - RES 225.00 ' DIF PARK':'MAINT FAC .-.RES 5.00 DIF PARKS/RREC - RES 502.00 STRONG MOTION (SMI). - RES .11.72 ..DIF; STREET'' MAINT. FAC -RES 15.00 DIF, .TRANS9ORTATI,ON - RES 109$..00 Fee summary Charged Paid Credited Due Permit Fee Total.; . 1012: 5;8 ab .00 1012.58 Plan Check Total T34.92 .00.. .00 134.92 _ Other Fee Total 2428:.14 .00� :00 2428.14 Grand Total -3575.64 ' .00 00 r. 357-5.64 Recording Requested By First American Title Company" when Recorded Mall Document and Tax Staterrrent To: . Mr. Mark F. Tuvell 50856 Washington_St., #149 La Ouinta, CA 92253 GO��6�-1 DI3:Rc�Ga `DOC tR Z0�4--033413 eailaiz0e4 es�eea Fee:ci.e0 Page 1 ori 1 Doc T x -•Paid Recorded to oTafficiai Records County of Riverside` Gary';L, Orca.' Rs9e�sor",. County,,C,ltr,k, b Recorder' IIIIIII�IIIlllallll�lfliil�llll�lllllI�Illl�lll�IIIII�MII1111 10— -mma.mm I- Hr \UMMlriMWOMMOMMMME MM -GRANT., DEED The undersigned grantor(s) dec(are(a) Documentary transfer tax Is $231.00 [ X ] computed on full value of property conveyed, or. [ ] computed on.full value iesavalue _of liens or enc u"mbrances-remaining at time of sale, ( ] Unindorporated;Area City of La Quinta FOR A VALUABLE CONSIDERATION,.receipt of wftich &Zwe r4cknowledged,, Frank Myrl Griswold, Successor.Trustee of the Henry. Griswold Living .Trust dated June. 19; 1995 • ' i hereby GRANT(5) to Mark F. Tuvell, Q -v,�o vutct fit %7 50La O -Ad, 5elja4-bt e. -'kV tha foUowing described reel property jn the Chy of La_ Quinta County of Riverside atate.of CEsI6r nia: Lots 1.& 2, Blodk'l62'os Santa Carmelite at Vele La Quinta, UniCAc17, as per map .recorded in -Book 19, Pages 19 & 20 of Maps, in. the Office of the County Recorder of=said County. . DATED: July 6, 2004 STATE OF CALIFOR COUNTY OF ON ` tiefore me, S.. oersonall.y appeared personally known to me (or proved.to•me on the'basis of satisfactory evidence) to be the persofft',whose name) is/ft subscribed to the within instrument and acknowledged"to ;me that held Ithv'y, ekocuted the same in his/l%dttil9ir authorized copocity(Te4, and that by his/fly/their signatureN 'on ,.the instrument the personN, or the entity tjpon behalf, of which the personNacted, executed the Instrument. Witness my hand and official seal. Signature MAILTAX STA Fp-213 (Rev 7196) Frank Mi rl Griswold, Successor. Trustee of the Henry. Griswold Living�Trust.dated=June 1 9951 �,:�f Frank yrl .Griswold; Tr ee LiNDAA GACNdN _ Comf�iEzion� 1313p93 �> .v Nota!; Pubfic-Calitomia z Oranao County - My Co nr I E:cpirpy Ju113, 2005 -•r`^i. .'A5 DIRECTEIM Z0 .39dd' ONI S1W b000ZLL09L GT-ZT b00Z/9T/60 Date 9/21/04 No. 26446 Owner Mark Tuvell Address City Zip Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands ands Unifiedt, 666f., K;* ..District -47950 DUhe PaIni64R6,ad La QuintA,9,2.-25-3 (760) 771-851.5 APN # Jurisdiction Permit:# Study Area No. of Units Lot # No. Street S.F. Lot .# No. Unit 1 52530 Avenida Obregon 1820 Unifl6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments 4 E Q BERMUDA DUNES V) RANCHO MIRAGE INDIAN WELLS PALM DESERT LA QUINTA INDa IO %- __ 773-285-002 La Quinta 1 Street S.F. At the present time, the Desert Sands Unified School- District.do.es. not collect fees on-garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities fo(liv 'in'g, sleeping, 'cook i ng, eating or sanitation) or replacement mobile homes. It has been determined that the abdve-n'amed is exempi'from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed, pursuant to Education Code Section 17620 and Government Code 65995 Et-SRq. in the amount of $2.24 X 1,820 S.F. or $4,076.80 have been' paid forthe property listed above and that building permits and/or Certificates of Occupancy for this square footage in -this propose'd project may now be issued. Fees Paid By CC/1 st Bank - Mark.Tuvell Check No. 74263 Name on the check Telephone 272-6044 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Sh on McGilvrey Payment Recd $0.00 $4,076.80 Over/under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve 6. otify you that the 90 -day -approval period in which you may protest the fees or tall, 7b other payment identified above will begin to run from the date on which -t ' he it ing or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authioriied to collect them on the Distr'ici('s) behalf, whichever is earlier. NOTICE: This Docu.ment NOT VALID if DLIpli6a"t6d Embossed Original- Building Department/Applicant Copy - Applicant./Receipt Copy - Acicounting co, of Occupancy V., .Certificate 0F'I1 Building & Safety. Department t This -Certificate is issued pursuant to the requirements of Section 109. of the' California Building Code, certifying that, at the time of issuance, ' this structure was in compliance with the _ E provisions of the Building Code and the various ordinances of the City -regulating building l 4j 1 s . construction and/or use. 6I I7 BUILDING ADDRESS: 52-530 AVENIDA OBREGON { Ez- (RI i� i Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-6078 { Occupancy Group: R3 Type of Construction: VN Land Use Zone: RC — — MARK TUVELL Address: 50-855 WASHINGTON ST #1.49 � ... .. - City, ST; ZIP: LA QUINTA,'CA 92253 By: KIRK KIRKLAND Date: MARCH 23, 2005 Building Official a� POST IN A CONSPICUOUS PLACE 1, P 'T �R}K a'DBE%MBE%SBE Company ` 780 N. 4th Street EI Centro, CA 92243 (760) 370-3000 (760) 337 8900 fax October 14, 2004. . . 7.7-948 Wildcat Drive Palm Desert, CA 92211 (760) 360-0665 Mr. Mark Tuvell (760) 360-0521 fax City of La Quinta 50855 Washington St. # 149 . La Quinta, CA 92253 Subject: Compaction Test Report.' _ 52_53A Aven•u. a=Obr-egon `.. . La Quinta; -California LCI Project No. LP04146. Dear Mr. Tuvell: ' Attached is a summary report,,of compaction tests made of fill within -the building. pad on the subject project site. Placement and compaction of fill soils were not observed by our firm.. The compaction tests were made.'in conformanee.'to Iii -place Density by: Nuclear Methods (ASTM 2922 & D3017) on October 12, 2004, and* the test -results are'attached. LIMITATIONS The tests results summarized in this report preserit.th'e moisture and, density only at the locations and elevations tested --on the specified dates. The density'testing :was performed according to the generally accepted, geotechnical engineering standards` -of practice that existed in the Coachella Valley of Riverside County at the time the report was prepared. No opinion is expressed as to the uniformity of the material, compaction,, A or adequacy of the material. to; perform as intended. No guaranty or warranty of the contractor's woik `'is made or implied. The test locations are approximate, determined by pacing. and sighting .from distinguishable -'field .features. In doing our work, we have relied on topographic and surveying, information provided by others. Avenue Obregon LCI'Project No.:LP04146 Natural or imported soils. (if any) at. one foot or -'below existing pad grade,,i*ere not investigated ortested by our.firm.._.No warranty is *mad 6"As. td. th of ihese soils. With any manufactured product,. there ..ar'e statistical _variations in its iiiiiformity and in the accuracy of tests used to determineits quality. compared to other manufactured products, field placement of materials usually presents large. statistical vaiiations.in'its uniformity and in the accuracy of the test results. Thus,' even with careful observation and*testing, all parts of the constructed product may riot comply with, the job iequir'6 merits. Therefore, our bpiniori means - that there is only. -a statisiticall' -baS &d. robability that the densities obtained comply.' With the j ob�Tequire* ments. This report, is issued - with the understah,ding that the, owner or his representative has the responsibility to insure'that this, report is submitted to the appropriate 'governing Agencies. Please review the test results and contact our office with any questions or comments. Sincerely yours; LandA rktonsuitants, Inc.. Greg Princil-.1 I"C UJ. �6. C 34 32 rn EXPIRES :09-3M5--- cfJ CML �TFOF Summary of Laboratory Tests Maximum Density - Optimum Moisture (ASTM D1557) Client: Mark Tuvell Project Name: 52-530 Avenue Obregon La Quinta Project No.: LP04146 Max. Opt. Mat. Density Moisture Type Description USCS (pcf) (%) 1 Gray Coarse Sand SP ` 127.5 9.0 2 Olive Brown Sandy Silt SM 118.5 10.0 Client: Mark Tuvell Project No.: LP04146 Project: 52-530 Avenue Obregon: Test of: Hnuce Part I est ��.i as Nest°; a '�. ' �, - Test .� �: `� e"S�r".� I` r-.�. �- `" y{;, �,z a`t ' Test�Ele�/ielDxyFteld �€�'dx�` :nit,Wt-..MCDensityC3omp ` � _ . 0 .. S� _ ,. ax;Relati�e �.�; �y� , fir.. � ��o " � l Note-est- TM t • ff.'s 1' 10/12/04 12'Sx12'E of N%E corner. 2 BSG.1 107.4 :14.8 =118.5 91 P N 2. 10/12/04 14'ExlO'N of S/W corner ' <2 ,-.BSG-1.:113..4'. 11.4. 118.5 .96 P N 3 10/12/04 14'Wx9'n of S/E.corrier 1 FSG 119.6 .13.8- 127.0 94 P N 4 10/12/04 12'Nxl'E of SAV corner 1 FSG: 120.0 5:0 127.0 94 P N u { x e ► of Qur�� Title :24 Report for: u►LOING sqF ETy DEPT FOR PC ROVE® N� T U TION La:.Quinta CA 92253. pA T -E *-�_Z BY SSS -5-30 Projett.- Designer: Mark Tuvell Report Prepared B.y: `Jason Campanella 50 855 Washington `St #149. La Quinta,' CA 92253 (760) 590-9501 66 Nu nber: 0005. Date: 8/1.8/2004 The EnergyPro computer,program has been used to perform the dalculations summarized,in this corn pliance,report. This program ;has approval and is ' authorized by the California Energy Commission'fot use with both the Residential and.Nonresidentiaf2001` Building Enerby Efficiency Standards. This program'developed`by EnergiSoft, LLC,(415) 883-5900. EnergyPro 3.1 By.EnergySoB ' Job Number. 0005 User Number. 5961 TABLE OF. COI Cover Page Table of Contents Form CF -1 R Certificate 'of Compliance Form MF -1 R MandatoryMeasures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number: 0005 User Number 5961 1 y t l f Certificate of Com liance ,_;Residential ,,.:.. (Parte tof 2) CF -1 R 8/18/2004 Project Title Date La Quinta Project Address Building Permit # Jason Campanella (760)'5,90-;-9501 Plan check /Date Documentation Author • .Teleplhone. Computer PerforMance 15 Field.Check / Date Compliance Method (Package or Computer) Climate'Zone Enforcement Agency Use Onlv GENERAL INFORMATION Area Total Conditioned Floor Area: 1,821 ft2 , Average Ceiling Height: • 9.0 ft Total Conditioned Slab Area: 1, 821 ft2` Building Type: SF -UmFactor (check one or more) _. ... ® Single Family. Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing.Plus Addition Front Orientation: All Four OrientationS Floor.Construction Type: Slab. Floor Number of Dwelling Units:' 1.00 Number of Stones: 1 ❑ Raised Floor BUILDING SHELL INSULATION, Const. Component Frame Assembly.: Location/Comments Type Type' U -Value: .(attic; garage,Atypical, etc.) Slab On Grade n/a :0.756 Covered Slab:w/R-0.0'.Perimeter Insulation R-15 Wall (W. 1 5.2x4.16) Wood 0.081' `Exterior Wall R-38 Roof (R.38:2x4.24) Wood 0:024'. Exterior Roof FENESTRATION 'Shad!n ,Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF -UmFactor _. ... ;,. Shadin . Yes/ No Yes [ No Left _ 33.4V 0.74 0.66 Bug Screen ❑ x❑ ❑ X❑ Left 4.5 0.46 y 0:37 Bug Screen❑ X❑ ❑ X❑ Rear 32.0 0.61 .0.39- Bug Screen ❑ X❑ ❑ X❑. Rear 12.6 0.46. = 0.37 Bug Screen ❑ X❑ _J X❑ Right 6.0 0.61. ' 0.39' Bug Screen ❑ x❑ ❑ X❑ Right 12.0 0.46' • 0:37 Bua,Screen ❑ x❑' ❑ X❑ Right 33.4 0.74 0.66 Bug Screen ❑ X❑ ❑X❑ Front 33.4 0.74 0:66 Bug Screen ❑ X❑ ❑ X❑ Front 26.7 6.46 0.37 Bug Screen ❑ Q ❑ X❑ Front 72.0 0.61 ;0.39 Bug Screen- ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ un'I itia ion i e:.° /.1810406:36.56 Run Code-, 109283621 Ene Pro 3:1 By Ener Soft' User Number: 5661 - , Job Number 0005 Page: 3 of 13 Certificates ofC.ompliance.•, , R.esiden;tiaL __,, (Part 2 of 2) , CF -1 R WATER HEATING SYSTEMS - Rated YSTEMSRated-Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cep. or Recovery Standby Tank Insul. System Name Type Type Syst., Btu/hr (gal) Efficiency Loss (%) R -Value STATE S•"-52-1 HP Heat Pump_ Standard 1 15359 47 1-9n n/a n/a 1 For small gas storage (rated inputs of less than or. equal to 75,000 Btu/hr), electric�reslstance and heat pump water. heaters, list energy factor. For large gas storage water heaters (rated iriput of greater than 75,000•Btu%hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heater's; list Rated Input and Recovery Efficiency. REMARKS I+UIVIVLIANI+t ,'1 A I tIVItN This certificate of compliance lists the building',features;and performance specifications needed to;comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to, implement thern. This certificate figs been signed by the individual with overall design responsibility. The undersigned recognize,that compliance using duct'sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions'code) Documentation Author Name: Name: Title/Firm: Mark Tuvell Title/Firm: Jason Ca naariella,. Address: ..A Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) T 8/18/2004 Protect Title Date HVAC SYSTEMS .NoteAnput HydroMc or Combined Hydronic data unde► Water Heating Systems, except Design Heating Load. HeatingEquipment Minimum Dip.el.an on Type and Duet or; � Type (furnace, heat Efficiency :Location Piping Thermostat Location / pump, etc.) " (AFUE%HSPF)(ducts; attic, etc.) R -Value. Type Comments Central Furnace 92% AFUE Ducts in Attic 4.2 Setback HVAC System. Cooling Equipment Minimum . Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc.) , R -Value Type Comments Split Air Conditioner 12.0 SEER - Ducts in Attic . 42 'Setback HVAC System WATER HEATING SYSTEMS - Rated YSTEMSRated-Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cep. or Recovery Standby Tank Insul. System Name Type Type Syst., Btu/hr (gal) Efficiency Loss (%) R -Value STATE S•"-52-1 HP Heat Pump_ Standard 1 15359 47 1-9n n/a n/a 1 For small gas storage (rated inputs of less than or. equal to 75,000 Btu/hr), electric�reslstance and heat pump water. heaters, list energy factor. For large gas storage water heaters (rated iriput of greater than 75,000•Btu%hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heater's; list Rated Input and Recovery Efficiency. REMARKS I+UIVIVLIANI+t ,'1 A I tIVItN This certificate of compliance lists the building',features;and performance specifications needed to;comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to, implement thern. This certificate figs been signed by the individual with overall design responsibility. The undersigned recognize,that compliance using duct'sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions'code) Documentation Author Name: Name: Title/Firm: Mark Tuvell Title/Firm: Jason Ca naariella,. Address: ..A Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) T Certificate of Compaiance.. Residentals, ._ (Addendum) CF -1 R .8/18/2004 Project Title - Date SpecialTeatures.and Model.( Assumptions The local enforcement agency should,pay special attention to;the items specified"in this checklist These,rtems require;special written justification and documentation, and special verifiicaUon°to be used wAti:the performanceapproach.arhe local enforcement agency deterrhines the•adequac - i f the'justifi ' tion, and may;reject a; build ing orcdesign:that otherwise complies based -on the adequacy of the special:just�cation„and.documerit"on submitted:Plan: Field HERS Required Verification v These features.must be. confirmed and/or tested'bv a certified' HERS. rater under'the'sui)enrision of a CEC•abDroved HERS provider.. f ne ntKb,ratermust aocument the neia vermcatwn:ano aiagnosttc testing ot,.these measures on aform CF-OR.Plan Field The HVAC System "HVAC System” includes Refrigerant. Charge and Auflow.Credit'(ora TXV). A certified HERS rater, must provide verifification of the TXV, or measure the RefrigerantCharge and Airflow. + 66 -lnitiat o `..TI a ::081 8/ 06t36:56 ' , wRu :.Cod : 09 83 216! EnergyPro 3:1 By EnergySoft User'Num6ei `5961' Job Number OOQr- Page:5 of 13 '';, ' Mandatory. Measutes..Checklist: Residential_''.:: (Page 1 'of 2) NP -1 R NOTE: Lowrise residential buildings subject to the Standen must contain these measures regardless of,the compliance'apProach used. Items marked with an �;a,�y"S'.y'-�9i' ^ .en �r ?:as,g 9AV. asterisk (') may be superseded by more stringet _N%pliance requirements listed on the Certificate of• Compliance. ' When this checklist is incorporated into the permit documents, ttfe,feiYwres' noted shall be considered by all parties as minimum component performance specifications for the. mandatory measures whether they are shown.elsewhere in, the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable'boxes or:eMe-N/A:ifnot applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(a): Minimum R-19 ceiling insulation.'. , §150(b): Loose fill insulation manufacturer's labeled R -Value. f §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-vafue in metal frame walls (does not apply to exterior mass walls). ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmissiori rate no ❑ greater than 2.0 perm/inch. §118: Insulation specified or installed meets, insulation quality standards. "Indicate type,and form. ® §116-17: Fenestration Products; Exterior Doors and Infiltratiori/Exfilhation Controls 1. Doors and windows between conditioned and unconditioned spaces designed.to,limit_airleakage. s. 2. Fenestration products, (except field fabricatad)'have label with certified U -'Factor, certified'Solar Heat Gain ' Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped;'all joints'and penetrations caulked and sealed. - a§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.. §150(f): Special infiltration barrier�instelled 3o comply wifh.Section .151 meets Commission quality standards. El§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces` have: - a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots, allowed.' a \ Space Conditioning, Water Heating arid. Plumbing System: Measures I §110-13: HVAC equipment, water heaters, showerheads and.faucets certified by the Commission. I §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑X § 150(i): Setback thermostat on all applicable heating and/or cooling systems. FXJ §1500): Pipe and -Tank .Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 musf be eztemally wrapped with insulation having an installed, thermal resistance of R-12.or greatar. 2. First 5 feet of pipes closest to waterhaatei.tank, non-recirculeting•systems,' insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other. indirect hot water tanks have 'R-12 external insulation or R-16 combined intemaUextemal insulation. 4. All buried or exposed piping insulated in "recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page:6 of 13 � IYI ~ alnd'at _U .Measures Checklist; ;,:Res dential,:. (Page:2 of 2) MF -1 R NOTE: Lowdse residential buildings subject to the Standards must contain these measures rdless of the compbance approach used. Items marked with an asterisk (•) may be superseded by more:stringent complianee.regwremer is listed bmihe Certificate of Compliance: _When this checklist is incorporated into the permit documents, the features noted shall tierconsidered'byall parties,as minimum component performance spec cations for the mandatory measures whether they are shown elsewhere in the documents'oi on this chPckiil ft_nro 3.1' By EnergySoft UserNumber. 6961 ? Job Numtier. 0005 Page:7 of 13 DESCRIPTION' Instructionsi Check or Initial applicable;boxes.or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures:.(continlaed) FX] I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated; to a minimum installed level of R 4:2 or enclosed entirely in conditioned space. Openings shall be sealed'•with mastic: to �*' pe, aerosol sealant, or other ductclosure system. that. meets the applicable requirements of UL181; UL181A, orUL181 B. If mastic or tape is used to seal openings greater. than 1/4 inch, the combination cf mastic. and either mesh or tape shall be;used.• Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and theirrbmponents shall not be sealed with cloth back rubber adhesive duct tapes unless`such tape is'used in combination with mastic -and drawbands. 2. Building cavities, support` platforms for air.handlers, and plenums defned,or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveyingconditioned air. `Building cavities •and support platforms may contain ducts. Ducts iditalled in cavities and support platforms sfialtnot be compressed to cause reductions in the cross-sectional area of the ducts! 3. Joints and seams of duct'systems and their components shall not beseal`W with cloth back rubber adhesive duct tapes unless such tape is;used in combination with'mastic,and diawli ;rids. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned'space have eitherautomatic ogre' aIdkaccessible, manually operated dampers: 6. Protection of Insulation. Insulation shall .be protected from damage; including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation,exposed to weathershall be suitable for outdoor service e.g:, protected by alurhinum, sheet metal, painted`canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and. provides shielding from solar radiation that can cause.degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment, 1. Certified with 78%'thermal efficiency, on -off -switch, weatherproof opera_ ting instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 35' of.pipe between finer and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater -for future solar heating. b. Cover for outdoor pools or 'outdoor spas. 3. Pool system has directional inlets and,a circulation pump time_ switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking' appliances have no continuously burning pilot light. (Exception: Non�Iectrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specfied criteria Lighting Measures - §150(k)l: Luminaires for general lighting in kitchens shall have lamps with:an effrcagy 40iumens/watt or gr*br:for general lighting in kitchens. This general lighting shall be controlled'by a switch on a_ readily accessible lighting control panel at, an entrance to;the kitchen. , X❑ §150(k)2: Rooms with a shower or bathtub must•have either of Ieastone.luminaire with lamps with an efficacy of 40 Iumenstwatt or greater switched at the enhance to the room or -one of;the a@emativee.to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are It (insulation coverj'.pproyed. 3.1' By EnergySoft UserNumber. 6961 ? Job Numtier. 0005 Page:7 of 13 8/18/2004 Project Title Date La Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) . Design Space Heating 0.83 Facing North' Margin LIR-15 Facing, East Margin R-15 V1L la I_(1dL15 1 A) 1st Flnor Facing. South Margin Wall 318 0.081 270 90 Facing West Margin 0.28 0.55 t 0.11 0.72 0:05 0:78 0.16 0.67 Space Cooling 31.60 26.37 5.24 29.80 1.81. 30.19 1.4.1 28..67 2.94 Domestic Hot Water 13.84 11.14 2.70 11.14 ' 2:7.0 11 14 2.70 ❑❑ ❑❑ 11.14 2.70 37:79`8.49 41.04 5.23 41.38 ' 4:89 39.97 6.30 Totals 46.27 ❑❑ 18.3% This C -2R describes the front facing North occurrence of. a four cardinal orientation analysis. Featuresiare identical in all orientations. Total Conditioned Floor Area: 1,821 ft 2 Building Type: Single Fam DetachOd Floor Construction Type: ❑ Raised floor ❑X Slab Floor Building, Front Orientation: -All. Four Orientations Total Fenestration Area: 14.6% Number of Dwelling Units: 1.00 -,Total Conditioned;:Volume: 16,389 ft 3 Number of Stories: 1 Total ,Condiiibn e4 Slab Area: 1, 821 ft 2 BUILDINGZONE INFORMATION r.# of Thermostat Vent Zone Name floor Area Volume Units Zone -Type 'Type Hgt Area y.VAC$ystPm �1 R21R91 1�_-'38q On randlflnnafl Setback _� n/a OPAQUE SURFACES Solar ' Act. Gains TVDe Area U -Val- Azm- . Tilt Y/M Fnrm.3 Rafdironro i +:.... t I�.,........w<<. Wall- 124 0.081 _go go wall- 387 0 081 180 90❑ X LIR-15 Wall- (W `152Y4-16,) 1 st Flnnr R-15 V1L la I_(1dL15 1 A) 1st Flnor . R-15 wall '(W 9; 2Y4 IStEoN Wall 318 0.081 270 90 X ❑ ❑... Wall -3.09. 0'.081 Q 90, R-15 Wall- (1N 1F 2Y4 16; 1st=Floor Roof 1,821 0-024 0 _Q❑ • R-38 Roof (R 38 • Y4 24). 1 qt Floor ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ ❑❑❑°❑ --- _ ❑ ❑ M ❑❑ ❑❑ ❑❑❑ ❑❑ F] 1-1 Run Initiation Time: 08/18/04 06.36.56 Run Code•' 1092836216 3.1 By EnergySoft User Number: 5961 0005 Pane:B of 13 n In iatio Ti 'eLQ811 $164 06:36.66 kuh EnergyPro 3.1 ByEnergySoft User Number: 5961 Job Number. 0005 Page:9 of 13 f tom uter Method;,Summa : „ . _e Part 2 of 3 C -2R 8/18/2004Date Project Title FENESTRATION SURFACES u- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window LPft (East) 334 0.740 0.66 90 Mtl Thermal 13rk Clear D 2 Window Left (East) 4.5 0.460 0.37 90 _90 fa nft 90---Mtl Thermal:Brk Clear Default 1st Floor 1st Floor 3 Window Rear (South) 1610 0.610' 0.39 180 90,Mb Thermal,Brk'ClearDefault 1st Floor 4 Window Rear (South) 16.0 0.610 0.39 180 90 Mb TFiermal Brk Clear Default 1st Floor 5 Window Rear -;South) 12.6 0.460 0:37 180 90..Mt1'Thermal Brk Clear D'efauft 1st Floor 6 Window Right (y)lest) 6.0 0.610 0.39. 270 90 .Mtl Th`ermal�Brk Clear Default 1st Floor L Window Redht(W(West) 12.0 0.460 0.37 270 90 Mtl Thermal &k Clear Defauft 1st Floor 8 Window Right (West) 33.4. 0.740 0.66. 270 ' 90Md Thermal Brk Clear Defauft 1st Floor 9 Window Front (North) 33.4 0,740 _0!66 Q_90 Mb Thermal Brkbear DefadM st Floor 1Q Window Front (North) 26.7 0.460 `0.37 0 \ 90.1VItl Thermal Brk•Clear`Defauft _9 1st Floor Window Front (North) 35.0 0:610 0:39 ' 0 90 -Mb Thermal Brk Cleai Default 1st,Floor 12 Window Front (North) 12.0 0.610 0.39 0 90 'Mtf The'rmal•Brk Clear Default . 1 st Floor 13 Window Front (North) 25.0 0.610 0.39 hermal 6rk'Clear Defauk 1st Floor TERIOR'AND EXTERIOR SHADING Window Overhang Left, Fin Right Fin Exterior Shade Type SHGC Hgt. Wd.. Len. Hgt. LEXt. l2Ext. Dist. Len. Hgt. Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Buq Screen 0:76 5 Buq Screen 0.76 6 Buq Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen '• 0.76 10 Bug Screen0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen _ 0.76 _ f n In iatio Ti 'eLQ811 $164 06:36.66 kuh EnergyPro 3.1 ByEnergySoft User Number: 5961 Job Number. 0005 Page:9 of 13 t w Computer Mothod Summary,... (Part:3'6f 3)C -2R 8/18/2004 Project, Title Date THERMAL MASS FOR HIGH MASS•DESIGN Area Thick. Heat, Inside, Location Type (sf) <(in.) Cap. Cond. ' Form 3 Reference R -Val. Comments Frame Wall, Stucco 124 0.88 21 047: R-15 Wall (W_152x4-.16) 1st Floor./ Exterior Marc Frame Wall, Stucco 387 0_88 _ .. 21 0_47 R-15 Wall'' _(W 15:2x4116) 2 'lit Floor/ Exterior Mass Frame Wall, Stucco 318 0.88 " _ 21 0.47 R 15 Wall"` (W:15.2k4:16) ' 2 1st Floor/ Exterior Mass Frame Wall, Stucco 309 0.88.- 21 0.47 R-15 VNall (W:15.2x4.16) 2 1st Floor / Exterior Mass PERIMETER LOSSES F2 Insulation Type Length Factor R -Val' Depth Location / Comments .HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location ' Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(duct$/attic, etc.) R -Value Type Comments Central Furnace 92%AFUE Ducts i6 At6c 4.2 Setback HVAC System Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct - Type (air conditioner, -Efficiency:. Location Duct . Thermostat Location / heat pump, evap. cooling) (SEER) , (attic, etc). k -Value Type Comments Split Air Conditioner 1 02. SEER . Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Rated Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution .# In; Input - Cap. ...or Recovery Standby. R -Value System Name Type Types Syst.: (Btu/hr) (gal) Efficiencv Loss (%) Ext STATE S"-52-1 HP Heat Pump Standard 1 15,359 47 -1.90 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr),.electric resistance and heat pump water heaters, list -energy factor. For large gas storage water heaters (rated input.>'75000`.Btu/hr), list Rated -Input, Recovery Efficiency and`Standby Loss. For instantaneous gas water heaters, Iist.Rated Input, and,Recovery:Efficiency. ,EMARKS Run Initiation Time: 08/.18/04 06:36:56 Run Code: 1092836216 . EnergyPro 3.1 By EnergySoft User Number: 5961 . Job Number: 0005 Page• 10 of 13 ' r T .r r, omputer IVlethod Summary „ (Addendum)C2R 8/18/2004 Project Title Date Special Features and Modeling'Assumptions The local enforcement agency should>pay special attention to the items:spec�ed in this checklist: These items require special written just cation and documentation; and special ver cation to tie used vr'ith the performance:approach. ' The enforcement agency determines the adequacy of the; justification, and: may refect a building 'or design that otherwise complies based on the adequacy of special justification and documentation submitted. Plan Field HERS Required Verification These features must be confirmed arid/or tested• by a certified .HERS rater under the supervision of a.CEC approved HERS provider: The HERS rater, must documenf'the field'verification and diagnostic testin * "U'these,measures on a form CF -6R: plan Field The HVAC System "HVAC System" includes Refrigerant Cliarge and Airflow Credit (or a TXV). A certified HERS "rater must provide verifification of the TXV, or measure the Refrigerant Charge; and Airflow. . Run -Initiation Tlrne::08/1'8%04:06t36 56. _ Run Code:'. 1092836216 EnergyPro 3.1 ByaEnergySoft' User Number: 5961 Job Number 0005 t. Page: 11 of 13 . Run -Initiation Tlrne::08/1'8%04:06t36 56. _ Run Code:'. 1092836216 EnergyPro 3.1 ByaEnergySoft' User Number: 5961 Job Number 0005 t. Page: 11 of 13 HVAC SYSTEM, HEATIM PROJECT NAME SYSTEM NAME HVAC Svstem Number of Systems COIL HTG. PEAK Heating System Output per System .56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 30.8 Cooling System Output per System 35"000 Total Output (Btuh) 35,000 Total Output. (Tons) 2.9 Total Output (Btuh/sqft) A9.2 Total Output (sqftrron) 624.3 Air System CFM per System 000 Airflow (cfm) 1,300 Airflow (cfm/sqft) 0.711 Airflow (cfmrron) 44 5.1 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note.: values above givenat ARI.condiitions� N OL IN �Ilt Tbtal Room: Loads Return -Vehted:Lighting 'RifUm Ali Ducts Reftim Fan Ventilation Supolyfan Supply-AirDucts SUMMARY DATE 8/18/2004 FLOOR AREA 1,821 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible lLatent � CFM I Sensible 2,524 32,199 26,138 .10 COOLING SYSTEIVIRSYCH ROM ETRICS'lAirstreaim Temperatures 1,610 1,307 .0 0 0 0 0 0 #s 0 1,610 1,307 TOTAL SYSTEM LOAD 35,419T77;:278 28 752 HVAC EQUIPMENT SELECTION BDIP'C0,563AN036-A 19,801 13,846 56;000 Total Adjusted SyMem'.0utput 19,8011 :1 3,;�6] 56,0001 (Adj6i st�d for 4,ig* 'Peak De'sn Conditions') - TIME .QF SYSTEM 'PEAK - I Aug 2pmj I Jan 12 am HEATING SYSTEM PSYCHROMETRICS11.1 (Alr9ttbain Urho6eatuir6!§"atTime df M6atffiqRealkt, 26.0 OF 69.1 OF 69.1 OF -109.50f O .01 Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 108.6 OF 1360 cfm R007M751 69.1 OF _Return 'Ali Duets:; COOLING SYSTEIVIRSYCH ROM ETRICS'lAirstreaim Temperatures if.,,Tii6e"6f,Co6iiiiq�PeAk) 111.0 177.6 OF 79.2 69.5 OF 79.2 69.5 OF. -,"64'.9 64.1 OF supply>Air Ducts #s Outside Air 0 cfm Supply: Fan Cooling Coil 66.0 64.5 OF 1300cfm64:5% ROOMS R.H. of 78.0169.1 OF 79.2/69.5 R4um­ Ar Ducts;;,: I EnergyPro 3.1 By EnergySoftUser Number: 5961 Job Number: 0005 Page: 12 of 13 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page: 13 of 13