Loading...
09-1047 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA. 92253' Application Number: 0'9=0`0'0-01A47 Property Address: 52625 AVENIDA OBREGON APN: 773 -284 -018 -5 -000000 - Application description: REMODEL - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 25000 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT -- ---------------------------- --------------- LICENSED CONTRACTOR'S DECLARATION "I hereby affirm under penalty of perjury that I am licensed.under provisions of Chapter 9 (commencing with Section 7000) of.Division 3 of the Business and Professionals Code, and my License.is in full force and effect. License Class: B License No.: 717813 �Date:T'►2- Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 703'1.5, Business, and Professions Code: Any city or county -that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a.signed statement that he or she is licensed pursuant to the provisions of the Contractor's State ,License Law(Chapter 9. (commencing with Section 7000) of Division "3 of the Business and Professions Code) or that he or she'is exempt therefrom and the basis for the allegedexemption:" Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to.a civil penalty of not more than five hundred dollars ($500): 1—) I, as owner of the property, or my employees with wages as their sole compensation, will -do the work, and the structure isnot intended or offered for sale (Sec: 7044,'Business and Professions Code: The Contractors' State'License Law does not apply to an owner of property who builds or improves thereon, and who_does the work himself or herself -through 'his'or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within - - one year of completion, .the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1—) I, as owner of the property; am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business. and Professions Code: The Contractors' StateLicenseLaw does not apply to an owner of property who builds or. improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - 1 _ )' 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMrT Owner: CRAWFORD JOANNA & 62625 AVENIDA OB LA QUINTA, CA (626)536-6052 94 ?�- Contractor': / - 4,�� AERY CONS UCT 52641 AVENID AE LA QUINTA, CA. (760)200-7910 Lic. NO.:. 717813 ct` VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/02/09 ---------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section.3700 of the Labor Code, for the performance of the work for which this permit is issued. - - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:. Carrier UNITED INS Policy Number 1890225-07 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become su ject to the workers' compensation provisions of Section 3s7or j+00 of the Labe, abort ith c m ly with those provisions. C—Date:-ft—Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND 'DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES°AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1: Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to -the work being performed under or following issuance of this permit. 2. Any permit issued as a resulCof this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,ayd hereby authorize representatives of this county to enter upon the above-mentioned property for in%)eetMn pses./y Application Number . . . . 09-00001047 ------ Structure Information REMODEL / ADDTN TO 1312SF SFD ----- Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2007 ---------------------------------------------------------------------------- # BEDROOMS .00 Permit BUILDING PERMIT Additional desc REMODEL/ADDTN TO SFD Permit Fee 252.00 Plan Check Fee 163.80 Issue Date . . . . Valuation . . . . 25000 Expiration Date 5/01/10 Qty Unit Charge Per Extension BASE FEE 45.00 23.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 207.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 38.62 Plan Check Fee 9.66 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/01/10 Qty Unit Charge Per Extension BASE FEE 15.00 169.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY. 5.92 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 6.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 2.70 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/01/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 ---------------------------------------------------------------------------- EA MECH VENT INST/ DUCT ALT 4.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 18.00 Plan Check Fee 4.50 Issue Date . . . . Valuation . . . . 0 LQPERMIT Application Number . . . . . 09-00001047 Permit . . . . . . PLUMBING Expiration Date 5/01/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 169 SF DINING RM ADDITION AND KITCHEN REMODEL TO EXISTING 1312 SF SINGLE FAMILY DWELLING. 2007 CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW FEE 16.38 STRONG MOTION (SMI) - RES 2.50 Fee summary" Charged Paid Credited --------------------------- Due -------------------- Permit Fee Total 328.12 .00 ---------- .00 328.12 Plan Check Total 182.84 .00 .00 182.84 Other Fee Total 19.88 .00 .00 19.88 Grand Total 530.84 .00 .00 530.84 LQPERMIT Bin # City of La Quint a Building 81; Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # r �7 D� I Project Address: 2 AEc" Owner's Name: M A. P. Number: �? . Address: � �2 / Legal Description: r Contractor: -ev w �i ��� , City, ST, Zip: Tele h ne �G 5 • o P � 4y1i 1 • Address: ;:�Z,6?(4 /sZ ( S Project Description: 2AAWAOM 1�g.........,.,rM City, ST, Zip:- �P TeleP h0 ne:' (n 2rYJ U Z State Lic. # : �i 3 City Lic. #.: Arch., Engr., Designer: / O Address: wt D City, ST, Zip: h e: Telephone: Tele P B • Lic �r Name of Contact Person: ?� Con struction Type: e: c Occupancy: P P Y• Project tYPe (circle rcle ne : New Add Alter Repair Demo Sq. Ft.: "' ` # Stories: # Units: Telephone # of Contact Person: 7�/� Io �0� Estimated Value of Project• APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitte Item Amount Structural Calcs. Reviewed, ready fo correcti Plan Check Deposit Truss Calcs. Called Contact Person (CA& Plan Check Balance. Title 24 Calcs. Plans picked up (Pj, '>) Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°d Review, ready for corrections�ssu Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 3" Review, ready for corrections/ i sue Developer Impact Fee Planning Approval Called Contact Person • A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees • Total Permit Fees qftl -`7 '017 CERTIFICATE OF COMPLIANCE 4w�Sco Desert Sands Unified School District y 47950 Dune Palms Road Q BERMUDA DUNES 0 RANCHO MIRAGE Cj Date 11/2/09 La Quinta, CA 92253 INDIAN WELLS PALMDESERT LA QUINTA y No. 30528 (760) 771-8515 `>, LANoD A Owner Mark & Joanna Crawford APN # 773-284-018 Address 52625 Avenida Obregon Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # No. of Units 1 Type Single Family Residence Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 52625 Avenida Obregon 169 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time -due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to in the amount of $0.00 X 169 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Steve Aery Check No. .0.00 Name on the check Telephone 760-20077910 Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected /exempted by Espe Lara Payment Recd . gver/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting �. TITLE 24 REPORT Title 24 Report for: Crawford Residence 52625 Avenida Obregon La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker South West Concepts 78120 Calle Estado, Suite 206 La Quinta, CA 92253 (760) 564-4707 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE A+1 - 1V+-1 Job Number: Date: 9/30/2009 /®11/7 SEP 3 0 2009 I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 5970 1J of . TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory.Measures Summary HVAC System Heating and .Cooling: Loads Summary Room Load Summary 1 2 3 7 9 10 I EnergyPro 4.4 by EnergySoft Job Number: User Number: 5970 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Crawford Residence Project Title 9/30/2009 Date 52625 Avenida nhregpn I a Uinta Project Address Building Permit # South West Concepts (760) 564-4707 Documentation Author Telephone Plan Check/Date EnergyPro Compli-56ce Method CA Climate 7nne 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.11 4.63 0.49 Space Cooling 178.83 148.36 30.47 Fans 25.01 20.65 4.36 Domestic Hot Water 15.59 15.59 0.00 Pumps 0.00 0.00 0.00 Totals 224.55 189.23 35.32 Percent better than Standard: 15.7% Building Type: [ Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition Ey� Existing + Add/Alt (E) 90 deg Natural Gas Area: 307 ft2 Avg. U: 0.73 Ratio: 20.7% Avg. SHGC: 0.58 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 44 n n74 R_19 R -n n 1R0 An Wall Wood 112 0 074 R_19 R-0 0 270 _go Roof Wood 169 0025 R-38 R-0.0 _go 0 Wall Wnnd 220 0 110 R_11 R_0 0 gn gn Wall Wood 288 0110 R_11 R-0.0 180 An Wall Wood 152 0 110 R_11 R-0 0 180 An Wall Wnnd 457 n 11n R_11 R_0 0 27n gn Wall Wnnd 100 n 11n R_11 R-0 n 27n An Wall Wnnd 284 0 110 R-11 R-0 0 0 gn Roof Wood 1 312 0 049 —R-19 R-0 0 go n Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: #'of Units Thermostat Zone Type Type —C cLd�flonPf1 Sethnnk 1,481 ft2 1,312 ft2 0 ft2 1,481 ft2 9.0 ft 1.00 1 Vent Hgt. Area 2 —nt Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Paae:3 of 10 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Crawford Residence 9/30/2009 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments -L- Window I eft (_S) 18.0 0.630 NFRC -QM NFRC 180 4Q_ New Dual Pane Low F Addition 2.0 2 Window Left (S) 40.0 0.630 NFRC 0_39 NFRC 180 90 New Dual Pane Low E Addition 2.0 3 Window Left (S) 18.0 0.630 NFRC 0_39 NFRC 180 90 New Dual Pane Low E Addition 2.0 4 Window Rear (W) 40.0 0.630 NFRC 0.39 NFRC 270 90 New Dual Pane Low E Addition 2.0 5 Window Front (E) 40.0 0.790 116-A 0_70 116-B 90 90 Existing Double Metal Clear Existing Living 6 Window Front (E) 40.0 0.790 116-A 0_70 116-B 90 90 Existing Double Metal Clear Existing Living L Window Left (S) 40.0 0.790 116-A 0.70 116-B 180 90 RemoveMouble Metal Clear Existing Living 8 Window Left (S) 18.0 0.790 116-A 0.70 116-B 180 90 Remove0ouble Metal Clear Existing Living 6 Window Left (S) 16.0 0.790 116-A 0.70 116_B 180 90 Existing Double Metal Clear Existing Living 1Q Window Left (S) 16.0 0.790 116-A 0.70 116_B 180 90 Existing Double Metal Clear Existing Living 11 Window Rear (W) 3.0 0.790 116-A 0_70 116-B 270 90 Existing Double Metal Clear Existing Living 12 Window Rear (W) 40.0 0.790 116-A 0_70 116-B 270 90 Existing Double Metal Clear Existing Living 1a Window Right (N) 16.0 0.790 116-A 0.70 116-B 0 -9Q- Existing Double Metal Clear ExistingJ i_ ving 14 Window Right (N) 20.0 0.790 116-A 0_70 116-B 0 90 Existing Double Metal Clear Existing Living 1. Indicate source either from NFRC or Table 116A. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 2. Indicate source either from NFRC or Table 1168. Window Overhanq Left Fin Right Fin Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 8.0 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.8 6.0 2. 0. 2.0 2.0 5 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 8.0 2. 0, 2.0 2.0 7 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 3.0 6.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 1.0 3.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 6.8 6.0 14.0 0.1 14.0 14.0 13 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.8 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Run Initiation Time: 09/30/09 14:13:58 Run Code: 1254345238 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:4 of 10 Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 33 None No Insulation 26-A1 New Addition Slab Perimeter 90 None No Insulation 26-A1 Existing Existing Living Run Initiation Time: 09/30/09 14:13:58 Run Code: 1254345238 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:4 of 10 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Crawford Residence Tank Energy 9/30/2009 Project Title Cap. Condition Factor Date HVAC SYSTEMS (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Livinq Zone Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Living Zone Ducted Ducted Attic 2.1 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Twe In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require instr testing and certification and field verification by an approved HERS rater. Designer or Owner r B ine s & P ' ' s Code) Documentation Author Name: �. Name: Joan D. Hacker Title/Firm: . Title/Firm: South West Concepts Address: / Address: 78120 Calle Estado, Suite 206 La Quinta, CA 92253 Telephone:7w/ Lic. #: Telephone: (760)-%4-4707 (signature) (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) User Number: 5970 Certificate Of Compliance: Residential. (Part4 of.4) CF -1R Crawford Residence 9/30/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the aaegUaCy or ine special7usuncation ano aocumentation suomittea. Plan Field The HVAC System "Existing HVAC' is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a VCDC w �;A w.4 •....1:.... .....11... �:[:���:�� —��L.— �����v r�v���G1 �J111y orrl v�cu LGJLI11y a11VIV1 YG1111LOLIVII IIIGLIIVVJ. Plan Field EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:6 of 10 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and.included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). b. outside air intake with damper and control, flue damper and control ❑ ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X 1. Masonry and factory -built fireplaces have: § 1500): Water system pipe and tank insulation and cooling systems line insulation. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ indirect hot water tank shall be insulated to Table 150=B and Equation 150-A. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ ❑ CF -6R Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ o ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150=B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:7 of 10 Mandatory Measures Summary: Residential . (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. a ❑E 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑X ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ o ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ Q ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:8 of 10 1HVAC SYSTEM HEATING AND COOLING LOADS. SUMMARY PROJECT NAME DATE Crawford Residence 9/30/2009 SYSTEM NAME FLOOR AREA Living Zone 1,481 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 70,000 Total Output (Btuh) 70,000 Output (Btuh/sgft) 47.3 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 39.2 Total Output (sgft/Ton) 306.4 Air System CFM per System 1,300 Airflow (cfm) 1,300 Airflow (cfm/sgft) 0.88 Airflow (cfm/Ton) 269.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 26.0 of 66.5 of 66.5 of Outside Air 0 } 0 cfm 66.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,164 30,677 2,736 604 28,030 0 7,237 4,835 0 0 0 0 0 0 0 0 0 7,2371 4,835 45 15 217361 37 699 Existing HVAC 48,744 0 70,000 Total Adjusted System Outputas 744 0l 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Supply Fan Heating Coil 1300 cfm k Return Air Ducts `i Supply Air Ducts 113.6 of ROOMS 70.0 of OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 83.2/61.2OF 83.2/61.2OF 48.0/46.2OF OI- 0 Supply Air Ducts Outside Air cfm Supply Fan Cooling Coil 53.2 / 48.7 of 1300 cfm 32.4% R.H. ROOMS 83.2/61.20F 78.0/59.4OF o_,.. — A:_ n.._._ UE I EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:9 of 10 ROOM LOAD SUMMARY PROJECT NAME Crawford Residence DATE 9/30/2009 SYSTEM NAME Living Zone FLOOR AREA 1,481 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 279 7,351 930 279 7,351 930 119 5,501 Existing Living Existing Living 1 885 23,327 1,807 885 23,327 1,807 485 22,529 PAGE TOTAL 1 1,164 30,677 2,736 604 28,030 TOTAL 1 1,164 30,677 2,736 604 28,030 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page: 10 of 10