Loading...
0008-336 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of o Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. ClassF ; Exp. Date B H fie ,1 OMI -12C Date!`y-7 Signature of Contractor ° OWNER -BUILDER DECLARATION / I hereby affirm under penalty of perjury that I am exempt fromlthe Contractor's License Law for the following reason: ( ) I, -as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered•for sale (Sec. 7044, Business & Professionals Code). ( ) I, as .owner -of the property, am exclusively contracting with licensed contractors toconstruct the project (Sec. 7044, Business & Professionals Code). 1 . I , ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION.' I hereby affirm under penalty of perjury one -of the following declarations: () I have and will maintain a'certificate of consent to self -insure for workers' Compensation,, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. V) I have and will .maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier, & policy no. are: Carrier Policy No. $TATR FUND 229-00 VAIT 004433' (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work -for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those)provisions. Date: a a. 1-14-7 Applicant r 0 J-1 Warning: Failure to secure Workers' Com pensattioR__C.1overage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions 'set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under'or pursuant'to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if .work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. / Signature (O.wner/Agent) ��'¢'+ '' D to y►�f •f'3�,i V -1Y- BUILDING PERMIT PERMIT# DATES /� VALUATION LOT + ' ; TRACT W9 11LIU52M44 JOB SITE APN I ADDRESS Cj4-1,70 A NIDA, OEM 374-204-42-5 OWNER CONTRACTOR/DESIGNER/ENGINEER W01,14,4 R.. -R ?tEMF :rlChMAS �,i"tlFFN' WILLIAM 1'1V.11,t:?F.�::L.. 56.9c;zj,1AC.Ka0H.nR___T 690O.TA00-ON irr 1 IMURWL CA 922" M 'THERMAL CA 92274 �;i80 3 •120L� C'Tldf 15-54 USE OF PERMIT SINGLE FAULY MVEL •w ��4�a�•+�`*I,.iS-PPEi;IMtIT VOES NOT 17NC3 VDCII BLOCK. .WAUJk'0011T'ra;"VE 1~v«?.Y TRACT CONSTRUCTION Do SP POI?d IMPAVO ' 635.00 Sy 5 Y11. WOOD "INCi7 200.00 L R OWN.' VER RUU,icY COM6`3TRUCTION. PEE 101-000-418,000 $7313.5A � PLA,_" CHIMC Fi92 101-000.439-318 $603.22 MC H AANICAL WE 101.000.421-000 435:sn �. P..UCTIUC.F,:L FST 4129.4 P11VUIIM0 FFIZ 101-000-419-000 fIP.,€4tiNO i1.9 I0I-000423-000 220.0it OV ELIMIFIR IMPACT psi $1,907,91i PRECISSE PIJAW ?.f?lst e3t.' 9 1.34 00.00 FKF DP'I'OSIT 16.1-090301-439•-318 4210100 4w + „ UB -1, `Ca'F:b�a z':C:�9s1TfZ1YC��ul. AIND.-PLAN Cr?YPX U1113 FRE -PAM TIM, 4250,00 TOTAL PKAMIT FEES DUE INOW 63,4' 34,06 a j} rs •. X • • RECEIPT DATE _ BY DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set BacksARA Ot j If Forms & Footings ` /l 2� _ 5� Underground Ducts Ducts Slab Grade _ Return Air Steel Roof Deck _ 2,- Combustion Air Exhaust Fans O.K. to Wrap Z -l( 57 F.A.U. Framing 2 . 2 -0/ S7 Compressor Insulation 3 (� � Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lathe Drywall - Int. Lath �� 9-Ol 57 w ' Final - Final POOLS -SPAS, BLOCKWALL APPROVALS steel Set Backs VreIWA.0 Electric Bond Footings® ' -- 9©J x Main Drain Bond Beam MaT .-00 2?7 Approval to Cover �%6• �- 3�-� Equipment Location -40 Of S 7 Underground Electric /sfj , 3.p �m ST Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Water Piping T0.1 /9 iD _ Heater Final �1 ?, - Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection _ �j - % - O �? Encapsulation Gas Piping Gas Test 5'r Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final (p o2(�O 57 Utility Notice (Perm) 45-. 5. LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 2.91728- B HAZ 08%31 /2( Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following. reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C, for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE FUND Policy No. 229-00 UNIT 0004483 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: ADDlicaht Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent) Date k-�li--c- BUILDING PERMIT PERMIT# DATE VALUATION LOT 0008-336 TRACT $127,097.90 8/9 BLK2 52 U24 JOB SITE ADDRESS 54-170 AVENMA OHREGON 774-204-025 T�l OWNER CONTRACTOR/DESIGNER/EER WILLL4M R.ROGERSITHOMAS BUFFIN WILLIAM RUSSELL ROGERS 56-900 JACKSON STREET 56900 JACKSON ST THERMAL CA 92274 THERMAL CA 92274 (760)399=1200 CBL4t 1954 USE OF PERMIT SINGLE. FAIVULY DWELLING 4 SFD.PERMIT DOES NOT INCLUDE BLOCK WALLIPOOLIDRIVE WAY APPROACH. .TRACT CONSTRUCTION 1,860.00 SF PORCH/PATIO 635.00 SF 5 FT. WOOD FENCE 200.00 LF OARAOE 814.00 SF ESTZIATED COST OF CONSTRUCTION 127,097.90 PERNIlT FEE SUMMARY CONSTRUCTION FEE 101-000-418-000 $737.50 PLAN CHECK FEE 101-000-439-318 $603.22 MECHANICAL FEE 101-000-421-000 $55.50 ELECTRICAL FEE 101-000-420-000 $129.88 PLUMBING FEE 101.000-419-000 $118.25 STRONO MOTION FEE - RESID 101-000-241-000 $12.71 GRADING FEE 101.000.423-000 $20,00 DEVELOPER IMPACT FEE $1,907.00 PRECISE PLAN 101.000-441-345 $100.00 FEE DEPOSIT 101-000-439-318 •$230.00 SUB -TOTAL CONSTRUCTION AND PLAN (_=CK $3,684.06 LESS PRE -PAID FEES -$250.00 TOTAL PERMrT FEES DUE NOW $3,434.06 RECEIPT DATE BY DATE FINALED INSPECTOR Titq� 0 4 " P.O. BOX 1504 78-495 CALLE TAMPICO ' Ird--wILA QUINTA, CALIFORNIA 92253 : ?", _ ljk_. o r o- ir— 4- APPLICAT� ONLY �)A a-� 1 t I BUILDING: TYPE'CONST. OCC. GRP. );�c A.P. Number I. 04') Legal Description ---�� Project Description Zip Tel. Gr T(o State Lic. City & Classif. ✓ f, 7� Lic. # Arch., Engr., Designer /A Address,, r Tel. 144 Q City IZip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3,of the Busines" and Professions Code, and my license is in full force and effect. SIGNATURE VW y % 9 _. DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I; I, as oner of the property, or my employees with wages as their sole compensation, will do the wowrk, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees. Provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1*7 1 am exempt under -Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company 177 Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permil is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: 9, atter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, Stale, Zip Sq. iz Ft. 186 C1 SNo.to No. sizg (� Stories Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ itimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: i Minimum Setback /70 Building Address 4 I } (� / Owner11 t� Mailing Yr Address ' ` M_/ Titq� 0 4 " P.O. BOX 1504 78-495 CALLE TAMPICO ' Ird--wILA QUINTA, CALIFORNIA 92253 : ?", _ ljk_. o r o- ir— 4- APPLICAT� ONLY �)A a-� 1 t I BUILDING: TYPE'CONST. OCC. GRP. );�c A.P. Number I. 04') Legal Description ---�� Project Description Zip Tel. Gr T(o State Lic. City & Classif. ✓ f, 7� Lic. # Arch., Engr., Designer /A Address,, r Tel. 144 Q City IZip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3,of the Busines" and Professions Code, and my license is in full force and effect. SIGNATURE VW y % 9 _. DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I; I, as oner of the property, or my employees with wages as their sole compensation, will do the wowrk, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees. Provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1*7 1 am exempt under -Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company 177 Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permil is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: 9, atter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, Stale, Zip Sq. iz Ft. 186 C1 SNo.to No. sizg (� Stories Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ itimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION ZONE: BY: i Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Linetf% INSPECTOR Date Pei _mit If 1 • i ri r, '%a -40, �1 FINAL DATE Issued by: Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Q Notice: Document Cannot Be Duplicated Date 10/23/00 No. 21130 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 760-771-8515 CERTIFICATE OF COMPLIANCE Owner NameWilliam R. Rogers/Thomas Buffin No, 54-170 street Avenida Obregon APN # 774-204-025 Jurisdiction La Quinta Permit # Log # City La Quinta Zip .92253 Study Area Tract # Lot # 8/9 Square Footage 1860 Type of Development Single Family Residence No. of Units 1 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: ti EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 2.05 X 1,860 or $ 3,813.00 the property listed above and that building . permits and/or Certificates of Occupancy for this square footage in this proposed project niay,,now be issued Fees Paid By CC / Valley Independent Bank / W.R. Rogers Telephone 760-399-1200, Name on the check �] 4 T fY By Dr. Doris Wilson Superintendent j►f�'`�` Fee collected /exempted by Annette Barlow Payment Received $3,813.00 Check No. 227477 NOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1998) this will serve to notify you that the 90-diy approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to collect them on the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting 11 fLecording Requested By, ' CHICAGO TITLE COMPANk RECORDING REQUESTED BY: CHICAGO TITLE COMPANY COMPANY 9834KC 207056022 - WHEN RECORDED MAIL THIS DEED AND, UNLESS OTHERWISE SHOWN BELOW, MAIL TAX STATSMIMS TO: WILLIAM ROGERS 56-900 JACKSON THERMAL, CA 92274 DOC N 2000-324929 68/18/nee 08:00 Fae:9.e0 Pape 1 of 2 Doc T Tax Paid Recorded in Official Records County of Riverside Gary L. Ors* Assessor, County Clark 8 Recorder M WSC, A R L COPY LONG REFUND NCNO EXAM G&4W DEED APN: 774-204-02s-9 o.� v -Il C— I' _ The undersigned grantor(s) declare(s): Documentary transfer tax is $31.35 (1QIX) Computed on full value of property conveyed, or ( ) Computed on full value less liens and encumbrances remaining at time of sale. i ( ) Unincorporated area: ( j ) City of —Lo, L: ; : ��„ and FOR A VALUABLE CONSIDERATION, receipt of Which is hereby acknowledged, MARJORIE JEAN CASE, TRUSTEE U/D/T DATED JANUARY 27, 1993 19 and JAMES F. CLARK DOROTHY LOUISE CLARK, TRUSTEES OF THE CLARK FAMILY TRUST U/D/T DATED JANUARY 31, 1983- 0 C hereby GRANT(S) to R- '� WILLIAMIROGERS, A MARRIED MAN AS HIS SOLE AND SEPARATE PROPERTY and WILLIAM THOMAS BUFFIN, an unmarried man, as joint tenants the real property in the City of LA QUINTA, County of Riverside, State of California, described as: Lot (s) 8 and 9, Block 252, Unit No. 24, Tract Santa Carmelita at Vale La Quinta, as per map recorded in Book 19, Page(s) 44-45 inclusive of maps, in the office of the County Recorder of said County. Dated April 13, 2000 v%,A State of California County of Tom" -� -A+A/$o. 4.1' ._ _} S.S. On Aox 1 p before me, &ZALt dI • personally appeared VC.- R.0 p on the basis of satisfactory evidence) to be the person(s) whose name(s) ie/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/Mr/their authorized capacity(ies), and that by hoe/ager/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. Signature MAIL TALC STA 3 4C ' PA,AZ ->� . a'4 --Z' MAR RIE JEM CASE. TRUSTEE OiMES F. CLARK, TRUSTEE A ,f .o / -•- DOROTHY J&BUISE CLARK, TRUSTEE ELVIN E. PATE Commission - 1167.367 �d NO:'ory Putlio „':!c,r-.:o Los Anc.eias Cc;:r ;y My Comm. Exp°res Feb I, 2002 (This area for official notarial seal) '. Y:' )-1wf dnifi..t 3C hi ?O"! T'•:f! U l!"ZITU. —11' • 2V-- ':(. f. 3 ? '^ TAAM L2u ; Y.I?'•L� ti`'(].'•IOU 7pu± a"; .9 c`':. Al! w b:1iz i;,iL'zs'�G Cl'-, 'r'rr3 OJ �r?1!x>ir.ii? SCI r.S� • 7i w. 7 „ ,rtr l ta` ♦» ! t Z .rnn1"„ `.'t' t• F 1 li T T ' At V eK r r f.k ..1 i1 _eif aCJ}:"k' •.ii .. ,, .Y !l l'C. rl '!:?/� i t'%+. �i r'�r'Aa4,r (.':,nib ,,�C.+c� [: a::r+ S+yr�. U 1.. i.. F1 r_... •.i a� .'.i..l.l:.l.. i ,;fj-- ?A , E,i:l~7:. i j � b_� �i:J 3.:Ei ��. ..._?� g'SL,rl.C� �C� Y:JCi1dC)�% , �:.�i.�.lj �'..I 3� 'r :; �:/ !I:.S I:i '•;1T;%�J if.� r S_'sT :r',: ec :s�;ir'x�„�:• ;1<„1 4”, '.).�.: �i �yti�•k7 G'1 fS' C;Gc, A1:m,,-,T 011.a 7i':1Cf.�F% ,1•, VJf`.t1C3 7C,. Its 9iJ'S1•J S::•, !•(t. f4?G ::1 7th V}i'[ f'J::. at -14 W%)pr(i ,Q. 'oDf! f; qF+ r '• Jai • �. w. �. �� 3'� ' .jc•. i .. .-...�-...s_..�. r._ �..(:.�7.x1ati-...t�}t.rt�.Y-i7;f :,S_.i �.r•y;,3t� .tL+�..-.rS�<,... N. e:e+•y; ws��.7r^'a:,l'C:�"7i.:c41�z.L':'c�.,yr,;.: Fm. fu:ii 1 if; �q rt,�'Ee: i;];z .t E3.C',J,t,.»`�O :•.:} [!•.i"31� cAli:'i'} 'ICJ #1 :3V,:i2 . C.. is r .._ ..._......_�'� ��w �%'y�`.:i�..C'%•S-K•>, :l? ��IzifCtiJ xr 2 r�'1 - •e e y � l � � ftfl �],^r•.,1.'`. �,,.b;ti•%,+.:s�4y ._-!;}.:....Yi �'•-z•.y.•-l-a,nw�:i�� _u•Y•1"Lci!'�.r rf� "�(l�=+i'"tr'J^.fd 4: b9di'I;t�rj•;2 J'.Yf:i;►< f.k}�irsn .:�Ctr.�' 1�+;;;;.?:;{�cY ::L`I:f L':1 L:�S��ki�1.':L,CSn'.'i: !:!^I\1 ?C:_�(:f1J'1'IE:11:. f'(:Si:i�•. �1l:1 (:i tSL :?l'':f3c'S :'if':` iI9,;L�:J�ii'� 'f'1:�:�'�'.'fw\'c'^%•: ?1�II.f ���. i`)1?i.g c ,r.'_•!J'y':��'7i:C{[.+;. �.:w✓b:..OI'•?!:t"s '.`i:.:�:��':'.'+i:�avi,,. - ••i yd :lrc fiCCtr `{':' 1na ��i1 :CS � �r'Si1ia,'rs-IV;4 91::1 "1': 'nm 'x. i>:a;:;17f3ic�` rLc"..:>8 t�3t�c;r�Y_�j �rrt3 r1�atS•a ,?+.i 'Ytt'.•(;ac 4)j161i y:1 r!"B:.'T:a•i 7:'>'c R�:?". _.l.'�'w 'rM,.�4i:7 'sr"y'w R•� ; `=.!f.�: :�,:'��,,,•-~.1 � �i ( .�:,� L'R? r..-:1':iei.Z�yfit�:� %'.'i.I:C1siG`!...F. I '' G.� i! �!: J�.1'� •i : .'. CUO� , �:: l.�c:: i�l�' .'r1"s 11•i'Ki ,.'f...`• L T,.. r.' -J.. t.� ( r• ".a .`e li 4}7 :i'J'1!i:J'•4Y 13 \1,'1 it .�: 14 r'i'!•I Mrd".!i ! 41,11 Ix � ,4�t fc' !+ �! {�q,'•<� i t 1:E 1"� i !e4 yll ";. f v '�' 1 } r t1 � `e;r` 1 .�. ..' .� ,fin (• -r:r.. - -- �- 144 f�e5(''lcs4,�i+I:i ,t! � ��f, f((�!,f, 11t�, 'w 4, 3` �, 5s# !t .� � ....... { r r .y,r f CJ •r �. .r,. f17f7 t"i �c..i: �.i F.. t tbC' a ..� !7!"�. i�� .{�s tr •. <- ...�. '�j l.Ypyy,{..-..wrr.w.,w:a�l •lw!{w�.r.wR.,'�6Yrr...,.lr.� ` t!Vv..+�wvw,.IrMv+M.Y4+.OMW.R_IifM•++N•Y`. �.. j .was N- C.A.►1a' r-1 �. 4 et,%i v ri��.i ::i i:i)`. a7'f:n.-: S"' b. -I rflJ I c3 .._.,. .. A,.:',r7v~c'., •,�,..,,..-.,�"�� :'i�ia.:�r iif:; r:L' ��-;c•rr.:-,_' i:.l�.tl � .:!!� •).s7 '3f 11:. �U LL:ifl.�Ld;irt'Y i:_1�:`.-3`-�iiSll;•!+t''l :il•;Ci f t3i1:1 J ..�Si. i0a[:}.i.a`� 1»i.1i no �i;1�41�.•Y!i}� 1 / ;[,S z :`•':iL:ic1 rAV ( '. Y:' )-1wf dnifi..t 3C hi ?O"! T'•:f! U l!"ZITU. —11' • 2V-- ':(. f. 3 ? '^ TAAM L2u ; Y.I?'•L� ti`'(].'•IOU 7pu± a"; .9 c`':. Al! w b:1iz i;,iL'zs'�G Cl'-, 'r'rr3 OJ �r?1!x>ir.ii? SCI r.S� • 7i w. 7 „ ,rtr l ta` ♦» ! t Z .rnn1"„ `.'t' t• F 1 li T T ' At V eK r r f.k ..1 i1 _eif aCJ}:"k' •.ii .. ,, .Y !l l'C. rl '!:?/� i t'%+. �i r'�r'Aa4,r (.':,nib ,,�C.+c� [: a::r+ S+yr�. U 1.. i.. F1 r_... •.i a� .'.i..l.l:.l.. i ,;fj-- ?A , E,i:l~7:. i j � b_� �i:J 3.:Ei ��. ..._?� g'SL,rl.C� �C� Y:JCi1dC)�% , �:.�i.�.lj �'..I 3� 'r :; �:/ !I:.S I:i '•;1T;%�J if.� r S_'sT :r',: ec :s�;ir'x�„�:• ;1<„1 4”, '.).�.: �i �yti�•k7 G'1 fS' C;Gc, A1:m,,-,T 011.a 7i':1Cf.�F% ,1•, VJf`.t1C3 7C,. Its 9iJ'S1•J S::•, !•(t. f4?G ::1 7th V}i'[ f'J::. at -14 W%)pr(i ,Q. 'oDf! f; qF+ r '• Jai • �. w. �. �� 3'� ' .jc•. i .. .-...�-...s_..�. r._ �..(:.�7.x1ati-...t�}t.rt�.Y-i7;f :,S_.i �.r•y;,3t� .tL+�..-.rS�<,... N. e:e+•y; ws��.7r^'a:,l'C:�"7i.:c41�z.L':'c�.,yr,;.: Fm. fu:ii 1 if; �q rt,�'Ee: i;];z .t E3.C',J,t,.»`�O :•.:} [!•.i"31� cAli:'i'} 'ICJ #1 :3V,:i2 . C.. is r .._ ..._......_�'� ��w �%'y�`.:i�..C'%•S-K•>, :l? ��IzifCtiJ xr 2 r�'1 - •e e y � l � � ftfl �],^r•.,1.'`. �,,.b;ti•%,+.:s�4y ._-!;}.:....Yi �'•-z•.y.•-l-a,nw�:i�� _u•Y•1"Lci!'�.r rf� "�(l�=+i'"tr'J^.fd 4: b9di'I;t�rj•;2 J'.Yf:i;►< f.k}�irsn .:�Ctr.�' 1�+;;;;.?:;{�cY ::L`I:f L':1 L:�S��ki�1.':L,CSn'.'i: !:!^I\1 ?C:_�(:f1J'1'IE:11:. f'(:Si:i�•. �1l:1 (:i tSL :?l'':f3c'S :'if':` iI9,;L�:J�ii'� 'f'1:�:�'�'.'fw\'c'^%•: ?1�II.f ���. i`)1?i.g c ,r.'_•!J'y':��'7i:C{[.+;. �.:w✓b:..OI'•?!:t"s '.`i:.:�:��':'.'+i:�avi,,. - ••i yd :lrc fiCCtr `{':' 1na ��i1 :CS � �r'Si1ia,'rs-IV;4 91::1 "1': 'nm 'x. i>:a;:;17f3ic�` rLc"..:>8 t�3t�c;r�Y_�j �rrt3 r1�atS•a ,?+.i 'Ytt'.•(;ac 4)j161i y:1 r!"B:.'T:a•i r I RC DISTRICT - PLANNING REVIEW FORM This form is to be used by CDD staff for review of single family dwellings in the RC (Cove Residential) District, in order to determine the applicability of compatibility'issues or need to require the filing of Master Design Guidelines by the applicant. It shall be transmitted to the Building and Safety Department as your correction list. Please attach additional explanations as necessary. APPLICANT w. R. ROGERS SITE ADDRESS II54- 0 Avenida Obregon APN 1� - ?� - �ZS BIN NO.: CASE NO.: 2 o o n - 2 a a LEGAL: LOT �6 d BLOCK '? Z- UNIT z4 S.C.@V.L,Q. CHECKED BY: Stan Sawa DATE: 3 0g) Inform the assigned Building plan checker upon your assignment to this case. The CDD Executive Secretary maintains a log book to track applications and assign case numbers. REQUIRED ITEM Y N COMMENT/CORRECTION Compatibility Review Case logged and number assigned Verify legal and APN information Consistent with MDG on. file (as. applicable V MDG filing required (5 filings since 9/3/98) Consistency with street/surrounding area:. Colors Materials Architecture Other Requirements: -R>r Go ib hf�� �19TA An Certificatel'of Occupancy City of La Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS: Use Classification: SFD Occupancy Group: R 3 54-170 AVENIDA OBREGON Type of Construction: VN Bldg. Permit No.: 0008-336 Land Use Zone: RC Owner of Building: WILLIAM ROGERS/THOMAS Address: '56-900 JACKSON STREET BUFFIN M. Building Official City: THERMAL, CA 92274 By: STEVE TRAXEL Date: 06-21-01 TITLE 24 REPORT Title 24 Report for: Residence Obregon La Qu.inta, CA Project. Designer: Report Prepared By: Joan D. Hacker Insu-form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: CITY OF LA OUINTA . BUILDING & SAFETY DEPT. APPROVED Date: FOR CONSTRUCTIO 10/10/00 DATE BY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Ddd/EnergySoft; LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number. User Number: 2655 ` TABLE OF CONTENTS. Cover Page1 ti .. Table of Contents 2 "1 Form CF -1 R Certificate'of Compliance 3 Y Form MF -1 R Mandatory Measures Checklist .6 Form C -2R Computer Method Summary - . ` - --7 HVAC System Heating and Cooling LoadsSummary' 11 Room Load Summary 12 T Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Residence Component 10/10/00 - Project Title Location/Comments Date Obregon La Quinta U -Value (attic garage typical etc.) Protect Address n/a Building Permit # x Insu-form Inc. (760) 324-0216 n/a Documentation Author Telephone Plan Check/Date Computer Performance _ 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only Exterior Door R-38 Roof (R.38.2x14.16) Wood GENERAL INFORMATION Exterior Roof 0.73 Total Conditioned Floor Area: 1.860 ft2 Total Conditioned Slab Area: 1,860f? Building Type: (check one or more) X❑ .Single Family Detached (SFD) ❑ Addition Alone ' ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family' ❑ Existing Plus Addition Front Orientation: (West) 270 dem Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 Raised Floor FENESTRATION Type . Const. Exterior Component Frame Assembly Location/Comments Type - Type U -Value (attic garage typical etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.081 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof 0.73 FENESTRATION Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc. shadescreen, etc. Yes / No Yes / No Front (West) 90.0 0.87 0.70 Blind- Bug Screen X❑ ❑ ❑ Q Front (West) 5.0 0.72 0.73 Blind Bug Screen X❑ Q ❑ Q Front (Northwest) 10.0 0.72 0.73 Blind Bug Screen X❑ ❑ ❑ Q Left (Northeast) 5.0 0.72 0.73 Blind Bug Screen[R] ❑ ❑ x❑ Rear (East) 50.0 0.72 0.73 Blind Bug Screen X❑ ❑ ❑ X❑. Rear (East) 23.0 0.87 0.70 Blind Bug Screen X❑ ❑ ❑ o Rear (East) 80.0 0.85 0.70 Blind Bug Screen X❑ ❑ ❑ Q Rear (Southeast) 5.0 0.72 0.73 Blind Bug ScreenX❑ ❑ ❑X❑ Right (South) 33.0 0.87 0.70 Blind Bug ScreenX❑ ❑ ❑ Right (South) 20.0 0:85 0.70 Blind Bug Screen X❑ X❑ Right (Southwest) 10.0 0.72 0.73 Blind Bug Screen 1:1 ❑ Q ❑ El El❑ Run Initiation Time: 10/10/0011:49:56 Run Code: 971174996 Ener Pro 2.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 12 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Residence 10/10/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum , Type and Duct or a Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Packagad Heat Pump 7.0 HSPF Ducts in Attic 4.2 Setback - Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc. Duct Thermostat Location / R -Value Type Comments Packaged Heat Pump 10.5 SEER Ducts in Attic 49 Setback Living 7nnP WATER HEATING SYSTEMS Rated 1 Tank Energy Fact' 1 External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A O SMITH WATER Small Gas Standard 1 46,000 50 0.62 n/a n/a PRODUCTS FPSH-50-234 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS VVIYIr'LlArvliCJIAI CIYIGry I This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Flusiness & Professions Code) Documentation Author Name: J./ Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-form Inc. Address: Telephone: Liic. Q#: W o' k (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-0216 (signature/stamp) (date) Run Initiation Time* 10/10/00 11.49.56 Run Codes 971174996 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: PageA of 12 ' 4 Certificate of Compliance: Residential (Addendum) ` ` `: CF -1 R 'Residence 10/10/00 ` Project Title Date Special Features and Modeling Assumptions , -The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies , ..... . , -1 .. ,Y .. X11 1" p.aa..... 1-1 auu uwumanwuWn auunuuru' Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1285 sqft Covered Slab Floor, 3.50" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 575 sqft Exposed Slab Floor, 3.50" thick at Living r HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CE approved HERS T r - -- - _ - .�. ��• ����...�• •••� �� —..tea...,.. a11U Unaynvauc LGsuny or mese measures on a corm cr-b K. Plan Field s EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 12 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. t� Items'marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate'of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. ` , . DESIGNER ENFORCEMEN Building Envelope Measures , ❑X '§ 150(a): Minimum R-19 ceiling insulation in wood'frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -value. ' F"§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. s ❑X § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch. r a§118: Insulation specified or installed meets quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. s Space Conditioning, Water Heating and Plumbing System Measures X❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA. , X] §150(i): Setback thermostat on all applicable heating and/or cooling systems. ' X❑ §1506): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.lnsulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. '§150(m): Ducts and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m). ' 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. X] §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions; no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. , 3. Pool system has directional inlets and a circulation pump time switch. r r a§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. ' Lighting Measures X] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting controlpanel at an entrance to the kitchen. RI150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 401umens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. �+Y --gy—, ; wc� ivunwci• ZtiOD Job Number PageB of 12 Computer Method Summary (Part 1 of 3) C -2R ,Resirience Project Title 10/1 n/nn Date La Ouinta _Obregon Project'Address Building Permit # - Insu-form Inc_ (760) 324-0216 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.10 4.82 0.28 Space Cooling 43.21 45.58 -2.37 Domestic Hot Water 13.65 11.51 2.14 Totals 61.96 61.91 0.04 GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 1,860 Single Fam Detached (West) 270 deg 1.00 1 Floor Construction Type: X❑ Slab Floor ❑ Raised Floor Total Conditioned Volume: 14,880 Slab Floor Area: 1,860 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Living 7nne 1860 14 880 1 nn OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Wall 365 0.081 270 go floor 20 0187 970 9a Wall 30 0.081 31 F 9n Wall 235 0.081 45 90 Wall 327 0.081 gQ 90 Wall 35 0.081135 gn Wall 235 0.081 180 go Wall 30 0.081 225 9Q Roof_ 1 asp 0 028 l an _n Solar Gains Y / N Form 3 Reference Zone Type Cnn( itinnerl Thermostat Vent Type Hgt. Area Cethark _2 n/a Location / Comments Living_7one I iving 7nne living 7nne Living 7nne living one Loving lone Il iying�o ig I iving 7nne Living 7nne EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 12 Computer Method Summary (Part 2 of 3) C -2R -Residence Project Title Date 10/10/00 FENESTRATION SURFACES U -Value Act. Glazing Type Location/ # Type Area SHGC Azm. Tilt Comments -I- Window Qnt Mesh 30 0 _0.870 070 ---27O_ _9.0 Dplible Mtl l lnnoat d Default 2 Window Front (West) 5.0 0.720 0.73 270 90 Double Mtl Uncoated Default Living Zone 3 Window Front (West). 60.0 0.870 0.70 270 90 Double Mtl Uncoated Default Living Zone 4 Window Front (Northwest) 10.0 0.720 0.73 315 90 Double Mtl Uncoated Default Living Zone 5 Window Left (Northeast) 5.0 0.720 0.73 45 90 Double Mtl Uncoated Default Living Zone 6 Window Rear (East) 20.0 0.720 0.73 90 90 Double Mtl Uncoated Default Living Zone L Window Rear (East) 20.0 0.870 Q]Q _90 90 Double Mtl Uncoated Default Living Zone 8 Window Rear (East) 80.0 0.850 0.70 90 90 Double Mtl Uncoated Default Living Zone 3 Window Rear (East) 3.0 0.870 0.70 90 90 Dol!b_le Mtl Uncoated Default living Zone 10 Window Rear (Fast) 30.0 0.720 0.73 90 90 Double Mtl Uncoated Default Living Zone 11 Window Rear (Southeast) 5.0 0.720 0.73 135 90 Double Mtl Uncoated Default Living Zone 12 Window Right (South) 24.0 0.870 0.70 180 90 Double Mtl Uncoated Default Living Zone 13 Window Right (Bout 9.0 0.870 0.70 180 q0 D9ubleMtl n oat d Default Living Zone 14 Window Right (South) 20.0 0.850 0.70 180 90 Double Mtl Uncoated Default Zone 15 Window Right (Southwest) 10.0 0.720 0.73 225 90 Double Mtl Uncoated Default _Living Living Zone INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len Hgt LExt RExt Dist Len Hgt Dist Len Hgt 1 Blind 0.47 Bug Screen 0.76 5.0 6.0 6.0 0.1 6.0 6.0 2 Blind 0.47 Bug Screen 0.76 5.0 1.0 10.0 0.1 10.0 10.0 _ 3 Blind 0.47 Bug Screen 0.76 5.0 4.0 6.0 0.1 6.0 6.0 _ 4 Blind 0.47 Bug Screen 0.76 5.0 2.04 0 0.1 4.0 4.0 _ 5 Blind 0.47 Bug Screen 0.76 5.01 0 2 0 0.1 2.0 2.0 _ 6 Blind 0.47 Bug Screen 0.76 -0 4.0 2.0 01 ?.0 2.0 _ -_ 7 Blind 0.47 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 8 Blind 0.47 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 _ - 9 Blind 0.47 Bug Screen0.76 1.0 3.0 2.0 0.1 2.0 2.0 10 Blind 0.47 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 _ 11 Blind 0.47 Bug Screen 0.76 5.0 1.0 2.0 0.1 2.0 2.0 _ 12 Blind 0.47 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 _ 13 Blind 0.47 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 _ 14 Blind 0.47 Bug Screen 0.76 6.8 3.0 10.0 0.1 10.0 10.0 _ 15 Blind 0.47 Bug Screen 0.76 4.0 2.0 4.0 0.1 4.0 4.0 _ - Run Initiation Tome; 10/10/0011:49.56 Run Cod • 971174996 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 12 Computer Method Summary (Part 3 of 3) C -2R Residence 10/10/00 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight x,2$5 _ IM 9R 0_98 n/a _2 Living Zone / Slab on Grade Concrete, Heavyweight 575 3_50 28 0_98 n/a 0 Living Zone / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 152 0_76 0.0 0 Living Zone Slab Perimeter 960_76 0.0 — 0 Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat ' Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Packaged Heat Pump 7.0 HSPF Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Packaged Heat Pump 10.5 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH WATER PRODUCTS Small Gas Standard 1 46,000 50 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 10/10/00 11:49:56 Run Code: 971174996 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Pa e:9 of 12 Computer Method Summary (Addendum) C2-R Residence 10/10/00 Project Title Date Special Features and Modeling Assumptions ,The local enforcement agency should pay special attention to the items specified in this*checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 1... ..A .. 6%......,.. _t aL_ ----- - - --- ---, -.... r .. . . .............. M ILLWU. Plan ,Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1285 sqft Covered Slab Floor, 3.50" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 575 sqft Exposed Slab Floor, 3.50" thick at Living HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS _ --_-.. ..._ .._.._ ._._...._... ................ .......�....�...wa�..,.. a.w u.aynwuc acauny yr mese measures on a Torm W --b K. Plan Field EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number Page: 10 of 12 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Residence 10/10/00 • SYSTEM NAME FLOOR AREA Living Zone 1,860 ENGINEERING CHECKS 1ISYRTFM I non Number of Systems 1 Heating System Output per System 57,000 Total Output (Btuh) 57,000 Output (Btuh/sqft) 30.6 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 31.2 Total Output (sgft/Ton) 384.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.08 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 of 69.0 of Outside Air 0 0 cfm Supply Fan 2000 cfm 69.0 of 69.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD HVAC EQUIPMENT SELE COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM Sensible 39,9681 3.721 CARRIER 50HS-060--301- 37,625 15,532 37,488 10.0 kW Supplemental Electric 34,130 Total Adjusted System Output (Adjusted for Peak Design Conditions) 37,625 15,532 71,618 TIME OF SYSTEM PEAK Aug 2 pm Jan 12am rstream Temperatures at Time of Heating Peak) ® 86.5 of m 102.4 of Heating Coil Aux. Heat Coil h Return Air Ducts `i Supply Air Ducts 101.4 of ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 177.4 of 78.8 / 66.6 of 78.8 / 66.6 of 61.3 / 60.2 of Supply Air Ducts Outside Air O 0 cfm Supply Fan Cooling Coil 62.1 / 60.5 of 2000 cfm 54.5% R.H. ROOMS �r 78.8 / 66.6 of 78.0 / 66.3 of Return Air Ducts I EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 12 . ;-o ROOM LOAD SUMMARY PROJECT NAME DATE Residence 10/10/00 SYSTEM NAME FLOOR AREA Living Zone 1.860 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Living 1 2,138 36,335 3,721 2,138 36,335 3,721 1,243 41,899 PAGE TOTAL 2,138 36,335 3,721 1,243 41,899 TOTAL 1 2,138 36,335 3,721 1 1,243 41,899 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page: 12 of 12