Loading...
BRES2014-1109Tor 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRES2014-1109 Property Address: 54310 AVENIDA OBREGON APN: 774242002 Application Description: 1992 SQ FT SFD Property Zoning: Application Valuation: $129,217.60 Applicant: ' GABRIEL RIOS 49901 CINNEBAR COACHELLA, CA 92236 C& Q D 4 QUM& VOICE ('760)"777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/14/2015 Owner: RW REAL ESTATE INC P.0 BOX 447 LA QUINTA, CA 0 E T 14 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. ' License Class: License No.: /,) Va*Cc:.-- AQ -lam\- S rontractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, therbuilding or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions.Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason -Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Contractor: Llc. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by . Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employany person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of SeJn370 of the Labo odeI sh fo with comply with those provisions. dhApph�cant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance oft ' his permit. 2. Any permit issueas a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to bui i g construction, and hereby authorize representatives of thy3�city topenter ug6n the� above-mentioned property for inspection purposes. N C tate U-kO_k4-'t S Signa (Applican "DESCRIPTIONACCOUNT• €: .QTY AMOUNT; PAID {PAID DATE; PLAN CHECK/PERMIT EXTENSION 101-0000-42600 1 $97.17 $0.00 PROCESSING ;T PAID BY. ` , .. METHOD' z' z ' ; RECEIPT # k ' CHECK # ,' CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 $0.00 - Total Paid for ADMINISTRATIVE: $97.17 $0.00 DESCRIPTION ACCOUNT ` YQTY ," AMOUNT " PAID . ` PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $6.00 $0.00 - -PAID � �" 4:.: ' ri r METHOD + "' �b.RECEIPT#.* CHECK # r".0 CLTD BY.E , Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 $0.00 ` - DESCRIPTION ° ACCO.UNT " >QTY - ^�.`AIVIOUNT '' PAID' —'PAID DATE`. DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 PAID.BY " . '4 - -PAID � �" � .METHOD"RECEIPT # '� �� ��� ^"CHECK #�_ } �CLTD BY + DESCRIPTION _'<�� ,DESCRIPTION r. < ACCOUNT' QTY..:':. `,AMOUNTc PAID, PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $0.00 PAID BY : "' s, w `PAID BY 4 METHOD RECEIPT # CHECK #F 'CLTD BY :... .. 'DESCRIPTION ACCOUNT` .' QTY ' AMOUNT` x PAID, PAIDDATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 PAID BY` . ; METHOD..:,RECEIPT # CHECK .# CLTD BY DESCRIPTION ACCOUNT ,' QTY' AMOUNT- PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 PAID.BY " . '4 METHOD ' x..: ' 'RECEIPT #: CHECK # CLTD BY + DESCRIPTION _'<�� .� ACCOUNT, ';QTY ,y AMOUNT'.'', : ` <� PAID PAID DATE DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $0.00 PAID BY : "' s, , METHOD ` .f f`" '. >RECEIP,.T # G� `• CHECK #.: t CLTD BY DESCRIPTION ACCOUNTt AMOUNT" PAID PAIDDATE' DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 METHOD. 3 . ' RECEIPT # • CHECK # s ., `-CLTD BY DESCRIPTION. xµ y v ACCOUNT QTY< a p. AMOUNT y : PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $0.00 PAID BY 7 Y METHOD { ` a , ° ~ RECEIPTi' CHECK # '' CLTD BY: ."DESCRIPTION ACCOUNT,.."QTY4 : AMOUNT�� PAID,',' PAIDDATE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 1 ME 1T.METH, D M 0 -# w -1;010B RECEIPT Total Paid for DIF SINGLE FAMILY DWELLING: $6,89400 ' Ar lN, g", 21,1 eklo"TI ON0 T W, XCOUNI IOUNTffi§ ''2"Ynt PAID -RM 1PAIMI) M IN K - 1, 1 �0 N , V, -H 1,9'0541- I&.W.Fm7jMm TEMP POWER SERVICE �101-0000-4I24I03I,' =+2 .17 $0.0 i 3§L �g -PAIWBYI`M�� m g� pq NIT2,14 ti*��7�!"�1*1�.,*��li%*,"ii��l- ki�lcfi- R E C E I -BW� MIR H, WREM 6, -N 44 ZZ, P-TWIM-71Y11 11CUT01 01, QUM* gear ACCOUNT,- c iu Q, 7 !, -5 _5 "I �MAUIDATU rugTION -Z T '"w"M SWEE 1� ...... . ......... 4022%-;� 051i �1- 47T-i� TEMP POWER:SERVICE. PC ",:"101-0000-42600,-,, 0 $0.00 M` PAID Y. 3. RECEIP R PR�'CH W. rzc. N "I'l 'X mv -1, ECK"W" 3-M51 CLTDBYz alPaidforELECTIRICAL�-' 0.00 , -- 1 gp_g gffip 5. ffll . bk �ACCOUUT -P N T LT` ;qg PAI .2 IN tnTv� 5�,� - , �� .,1 �11 A RESIDENTIALJA ADDITION 1,000SF '101-0000-42403, 24.66: RAIIRI��=19--- U;,�,Z- 'W"Imi. I- 'A N H 0-0 -1 �Iu mg "m mg Uw ,,.,CHECK4, -_4,1CLTWBy k j, =,Mal n1l 8.4 ggg, U ary AMOUNTtIN Mfflg 4 RESIDENTIAL, EA ADDITION 10000SIF,PC '101-0000-42600,'`$10.16 $0.0 0, WE URINE q "R,;�ki g 4 RUN 21.$ R, ,IXHECK� 7rO , ""I?, r Iw: 1 CUMBY-0; M-!* DESCRIPTION R, �r V`re�, '"M OUNTORP AM ,„',#-4, Z' WWI2, RESIDENTIAL FIRST 1,000SF 101-0000-424103� $0.00 5NIL. fflic Al lhl�llm, <ft. ftlw.]�Jl. I m ESCRIPTION 00,,,� mmf-��o� 04 RESIDENTIAL, FIRST 1,000SO"PC. 101-0000-426000 $47 86,. k MIN ODE r IPT RECEIPT 'T".-gg- -c txri� 7 ij 'Total Paid for ELECTRICAL X 'T j6 N: NEWONS RUCT 227-71-, !-,$0.00 !�ffl,=DESCRIRTION ffib il'i gx -w -:I, �"PAID- IOUNTA�WLJ,,'� gm, dVAIUMATE1 RESIDENTIAL,PRECISE GRADING CUSTOM ";101-0000 424 M HOME LOT <=7KSF. ........ ... "Rx.W A -0%,j PAI Y I 0-I, V�:zn N1025- -s 'gn, 'HOD" Q ffismsa"!� WN EF gg DESCRIPTION ;-,Df gg E 1� A m 7 R., "PAI RESIDENTIAL RECISE GRADING -CUSTOM i01-0000-42600 . 0 0. -HOME10T<=71(SFPC 7 At AR nr, pr g; "w m, s- -ggr, RE I P'T5 # C H E C K R �M-� C UT D1 BY IOU tw-14QMA N M U M, OEM g�.eg, glglgs gW,-ip� Total Paid for GRADING: 72.52 ."1'.:.,:;f'3, MI,.m- 'm .-M, Mi* PTIONM g, WIN. gp -.m y N iP 5 'PAUIDATU W�-`DESCRI h ANN J.Pi#T :PAID CONDENSER/COMPRESSOR ',L-�-,--�,",',�"..'�- -.-101-000074240i' boo,' IJ 'i€'.�..:�y���+w"+� ::.:vT. � y�.S K?. W" 2_;x ,. a� .0 „L %-6�... ¢eEva•'FRL� ,. < a .... __ . xRECEIRT#;CHEkCK#� aCLTDBY a"�`�UESCRIPTION?.sn..a A000UNT"< war r a,.,,%?rr.}, PAIf)�PAIDDATE s :a .:. esx., :.��rr� �., ; a:fi ...; a M4N�AMOUN�. ° CONDENSER/COMPRESSOR PCr;-; 161-0000-42600 '. 0 - $23 83 ',; $0.00 a rr E cl = -PAIDEBY13 vT Sk:T""� �k•."i Sy';''. ,&�,<.ft % IIu'3.',t.. 'f $ °vTa.,F, RECEIPT 8' Y.T `-'.<a"r-., s.R"n-,.,i s m sW� hl,- #_ , ' CHECK # _ f¢ LT BY -E. �D..'k k. �axr. aDESCRIPTION�,�;'=ACCOUNT �°. se .':a*�<. "�.. ,s:x f,;«;e^ ,,r 'AMOU,NT b ''P.i41DBAID DATE .ti s3r,..>r-.a.� xP`ii :;wTxe-.?*.r rr,,n::$i�:$:, k -k..... .-,sf ,,64m i wvr.F _ .c�,. :s,=, QTY ;_ 4, :»� a -: x�E....;�-as, 4i -`a'?.;::,,.:.. EXHAUSTHOOD; 101-000042402, 0 :;$11.92 $0.00 . T E:avCIP •„rwRECE - M” . 7# yyj *-Y pj�,.".Zgw,i, 2T: Cpi'S 6.-w-v_F..:&Yi^ 6P b. �t''<.¢ p• j•r - -: - +moi �:v� _ <q<`S" L_.1. qa.�,, ,: {,ti g gwlo�DESCRIPTION ..� s s "NOW, }9 C "' "4:rc " EACCOIHNT s 101=0000-42600 A i ' Vis+ �gTY�AMOUNT� 0 m[" YP"�l3 $4.77. 4 f�� PAIp $0.00 X .<k.:: il•:1..<d PAID DATE EXHAUST HOOD PC a �'�oMETHOD -'SE: 4 `x e RECEIPTS#;a� II .'`'F''� ', T CamW0.0"', CHECK .E,. ,... s E s CLTD BYg aYrl, a.<.•5Ilvi x s 010 ,�. # 3 , d >�p.. .w .a ';e':.'....'d?'a�-'L. L`E'.`,4.E'_ei `� X:s''i,X`ii '�€sraDESORIPTION�:��'�� '?`iYX'''➢�ie.x'S,S'.,. �i`rZ,'�"Xo?v<W ACCOUNT,*'� TYE':hAMOUNT ;�. :ar '*,..'A !. XEf4i.'Y»Lj:v+6xR..... . i k<�PAID""fi- .-v:A . {DDATE ERNE i ;7 S PI FURNACE 101-0000-42402• 0 '_ ". :$35 75 `„ $0.00 ,�a•e>9" �<F g PAIDrBY ,3. METHOD x RECEIPTk# ,� r < rk CHECK # CL=TDBY�. ,.j. ... .'...x.. ;P..:'rX:Y::.i.u.3f:'s.s`:<�.;c"a<>ema.z;?`t<tr:.. z -..,a ! a, zz�.dz:aF 3-: u...Y{4,-�"<�'" ,t,.','. t % @T ti`z'n DESORIPTION� .i , -ii ?{.<['!. ESS ...v4+,`:. ,.Y1 �...:.'?`-?- t{i'°,<,aY t -'ssACCOUNT z<as i Q TAY rsk'rig n �•- fi-AMOUNT4?�= L k «l F£„9 ta`u IBM PAID PAID DATE,,, +:3.7''`,k<`,r..tE'y'S:..,X,>.?'u:k:..'5n.,a.>:?3?ri`Fxt..=K'�:i:.if x:.Hfi.x.::l.''r,--`.i"D.sNkS.'!<.?E#h�,..w. 3 r.s..�.t:.<a ..max .v.a-az<mY.:dr a Ex. FURNACE PC C 101-W0042600 _ 0 .; •= $23.83 _ $0.00 z rkg n tel.., PAIDiBY3,,r, f;.METFIODi X-T"mS"Ye<a' EIPT#'� OHECK# "CLTD OY 4n,�.� f" ,.. # '"3 : .h ;a eS.nn<r -k}3i t 'W. as:S” ;i 'DESCRIPTION s, pR`, i5ft' '.SXLkESE. ri- �ACCOUNT.;'� 4;° 1E .Su <-iift'b'M'i :. Irmo TY�AMOUNT`P.AIU' F' 's."` z, n �?a��•. z.-:�'�ah� W �a R�3 • Q v ..: ., .0 .,. ,.,��. - -:9.. 2a z X .i PAID DATE VENT FAN '.:`' 101-0000-42402 : e 0 $35 76 $0:00 .,. % pAipgYaa `..01"%x$e1,^Sb Td, ..«re$eTF it,.,m•r.;' .i4lXq •.',ya ',3a, kaMETHOD °'v5' :E4s[k S.',yv�".1•"'°..'3�d .r. '�s RECEIPT.# �k ,ka� .. .v .. aA:.L£'t . 5. .. YSYR+:§z"%i. .-l:s:F.+f.?v .. ..,.. ri_4.. ]✓,. MM�a 3+'*.'.w"E"'x�< &�^. �.>» .._Siist. .taF'A L-S�.Pi .. .�'', � 'AJra�iu� k 3.':...<'i: >,.... `'<'�a' V"�"r A '.v� 'Y� bff Y.,.S.i 2 'Sv y f � 07ESCRIPTION ti� � S£'�e+4 '.3?'v :A vim. « S�SF - �e' -ri^ .:"ti'€' f ACCOUNT � ' 101 0000=42600:?$0.00 : ",�'�.t'ksS� ,�s;�x,4, � 'S=: !>{ (12 -k',<f'e A 'YF :ate R. �4TY M0UNTkr,PAID 5..,.. g_ fZ M=,-I�:'k`- +3iF( 8' M,v^ # �a�d`'-X�4S 4FAIDsDATE VENT FAN PC K"-.'-` a d} "�lWI0� METHOD �� h" �� .c� CHECK #g�� Total Paidifor MECHANICAL ',$185.92': $0:0 <, ; „q '-�yf �Sw•"`.' ii x DESCRIPTIONS , fhm21— = r "� N :, .x"'gt ''..S :,x-2' ...la::i $E 'i'SWs"'.: a:"v+ y �� � ACCOUNT Fra Q .x 6'.� 9Y:�$q gigT AM,OUNT k 'i *Mr PAID (r 4'.N,Aa,''�'g{�` �k :: AICD , .W.-RHOR n <. _` "x DATEq MULTI -SPECIES, RESIDENTIAL 8.1-14 UNITS 10t-0000-20311: 0 541.00 $0:00 2015'UPDATE -;r:�. a s;k {{J -ss�,.,� ra �?,up-, ax; --y- E'�Y4 kE.,p i'•:' :'4%"-�3 PAID BY�t{ ak" r. � , METHOD4II, RECEIPT,j#��CHECK # < ,- ,TR•L`'Ali xe �. BY n W .._=�:_ E f §_�...!<, � LTD Total Paid for MULTI -SPECIES RESIDENTIAL .,, f $541 00 rDESCRIPtTION %E �� 4� }, A000UN,T, TYa AM i. .x:��:��.'�;,..�.�.��?t:�..w^i,., af«•���.a<;�.�M�'.��z�,���,..�. P*��:. .. .�. `�•����e.> u4��.��ti�."�-a.:�-�UsN����eas���,�s��:PAID<,�'ir��sRPAIDDATE� NEW CONSTRUCTION PERMIT _ _" 101-0000-42400 0'$524 09. ; . $0:00 X:.a�'..Q:Rc*44`ry- ;yY ' fi c `.5a s P��A�n�ID;BY$ i *tet ; '.>a9 pf.. R'l ,a-jn,52`da° F �""Y _ METHOD, � ,,. fi RECEIPT -1 �.:'",<':.,x+'"'� ". t� r_ :... 5 - . IRE iivro�.,R.�-`�_..- --MY, !`. .Y"�a{iiaSi<.„T.Ern:Yx _:hQ<`n'.., :>". _,�.�.15- ,:.. ... `: '�""n.rt'-Xn.,�:v`-.: 5:.�.�'s?.z.hy,✓�s S.:s''D«xr..�:.N�'><:f�R,�-_sa-3?i..-.4�V;x4'zr�. # -+��„�x CHE . K # C i�e�:xi'rav�; sD2C -_.iv...r�..i��.�..v,..'.tm"+Y.hlim,'v:d.PY-e--: NCL BY� _ ... - .. - a Total Paid for NEW CONSTRUCTION PERMIT ', $524 09 $0:00 < 'um mig, 10- mw c PAID DATE NEW CIONSTRUCTION'PLAN CHECK 101'000042600. $760.00 $700-00'� 9/11/ 14 r- I PAID �F�MMMMM;6 N 'reM T� �q RECEIPT 11PT # -g g-pty 4 RE 3 �J. 1,,,, w F RR 'RW REAL ESTATEINC CHECK 308SI SKHI, W N"DESCRIPTIONZ-1 - �,j -g glp,, ME, W f f kg- - Np zNf �M , 4� 0 Ell 14 Wr4q.'N-91pi NEW CONSTRUCTION PLAN CHECK 101-0000-4260 $343 86 $ PAID BYn��T pFf.� -g"m ECEIP ll� R= 1�,CLTMBY g A F - Total Paidior,NEW CONSTRUCTION PLAN,CHECK $1;043 $i-'04* 0.00 -7figW2, WAMOUNT`� NIN �,..,PAIDV M ',4 IP 0 Jvi M B: , -j' -Al BACKFLOW DEVICE � 101_ 0000-42401 �0. $l 92 0.00 0 RE N ORNUR ffly "'I qu 101-0000-42600 T o '$4 -77 ffl 'I ft�- o $000 N-Af,,- IN ',-Zw` 60"V BACKFLOWDEVICEPC w !NE,� rallt 'K�*,-"-s;r�1-1.�ll,�lf.��4��tW� �g , m g. g =Z'0' CHE 4, W,:.�.. RM."! ?R. .1 4 =. W I Mzx., NOW. RIM10� .144�'llillleli�"5w�`;zl-w.�IK —W, yWR kl- 1,111 M, _E, aga PAIIJ IJA` BUILDING SEWER 101-0000-424011'$0.00 %0� g,4 PN TU g WNY 0- �m- 111 -R! METHODS E. - wo NRECfIP ECKW Pffislg'�, gq- -Mi- L, gl, sir..,-4�- IL11,1CH -wm 7 Qj a m ACCOUNT 0- a m Txg P QT IMP mffimw�m HIPAIM IN" Vml Wal BUILDING, SEWER PC 101-0006-42600 $11:92 $0.60i I�l , . vmg,, M 0"R III , METHOD W za ur rebIMF yq g n. DESCRIPTION,. -0, R �. , m... XOUNT--� R�Z' Jpl:- 0 0 0 -4 401 I , QTY 0 IOUNTt-�';MNT'� 131.12, $ - M .00. -FIXTURE/TRAP : *W gg 054 i��- N' E�ggp�, -MCHECK :METHOD xMRECEIPT RECE #t . ..... CHECK BYR:,! 4*-� "'MR44no. -v-Kl,,7,Eu RN WR -CLTD; -w bESCRIKTIOW W.R., N Nffli ig MAIN, g�_ , � Np-x. vqwy4" §_ , - - § PAID. 0, ' A 2. it, , A MR014im -MAN FIXTURE/TRAP PC' $131.12 0.�00 4 IBM, 4-j go," a 'MME CHECK7 , M. -r pz _RWIT-ON" M�ma'mmggum a :DESCRIPTION g, g , , , lk� N: 'g gva I @21i"'t"""'s., A q! mill F; M N' WAIMOATE ,GAS SYSTEM, S+ OUTLETS., 101-0000-42401; 1$ 0.00�--: 4EIN 0,111I.M m gwM p EV;0-111 ON M ,gggm le, MW R, R w I N WIM 'RE i4�4CLTD BY f. 3f ,,,e,,EDESCRIP;TJON54 ig', m 4., 04 fn w t% N: MOUNTQ, mm. ik -it�PAIW' `,0 IpAib'bAf El No W i� "ll GAS SYSTEM, S+ OUTLETS -PC: , 101-0000-42600,,' 0;00 X. pp PAID BYIS, F�`? METHOD2, T, flpr Wy r RECEI NCL-TDiBYM iE.-i mi 1"'I ,k % '0" XMMAW, uain BlOg"N-bvE jP , T , I , 0 N "- UNI Im M F �i $ ��;na, 4, s . t WATER HEATER/VENT 101-0000-42401 0 $11.92 $0.00 PAID BY ' ' METHOD , RECEIPT #' CHECK # — . DESCRIPTION;_ �" ACCOUNT.' '� - ' QTY `AMOUNT =`* �';-k<FAID �� PAID DATE: WATER HEATER/VENT PC 101-0000-42600 0 $7.15 $0.00 PAID BY 2c..#�=METHOD ., , + :' RECEIPT #; CHECK # CLTD BY' DESCRIPTION r - « . ;ACCOUNT °'' ° -, QTY4 AMOUNT, PAID ',PAID -DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $11.92 $0.00 PAID BY '' n_ a ,e ' METHOD` RECEIPT,# k CHECK # ` ,` CLTD BY . DESCRIPTION z r e`„ : s_ • ACCOUNT <QTY AMOUNT ' r .PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 • $11.92 $0.00 PAID BY « 6 ` `'` METHOD < =1" RECEIPT # CHECK # CLTD BY Total Paid for PLUMBING FEES: $405.26 $0.00 ,DESCRIPTION . 4 ACCOUNT : 't.„ ;QTY • AMOUNT• ` xE PAID.'% PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $16.80 $0.00 PAID: BY A` '} ` . METHOD " ,RECEIPT # ° " `" CHECK #, s CLTD BY Total Paid for STRONG MOTION INSTRUMENTATION SMI: $16.80 $0.00 s DESCRIPTION',i c:.. 5' ACCOUNT, NFr: ' -�QTY� _ ' .A ' r. ,: AMOUNT.-'- ;; x. 4 PAID. �,�sw e PAID DATE'' SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $0.00 PAID. BY ;,': ,METHOD a _; : RECEIPT # . ,CHECK # CLTD BY Total Paid for TUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:$700.00 r Description: 1992 SQ FT SFD Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: APPROVED Applied: 9/11/2014 SKH FAMILY DETACHED Approved: 10/1/2015 J10 Parcel No: 774242002 Site Address: 54310 AVENIDA OBREGON LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 266 Lot: 4 Issued: UNIT 24 rHROINIOLOGY ACTION DATE ` COMPLETION DATE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $129,217.60 Occupancy Type: Construction Type: Expired: 10/30/2015 BHA No. Buildings: 0 No. Stories: 0 No. Unites: 0 FROM CONSULTANT Details: NEW SINGLE FAMILY DWELLING. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALL, DRIVEWAY APPROACH, BBQ, FIREPIT, WATER FEATURE. HOME IS FIRE SPRINKLERED PER 2013 CRC CODE. APPLICATION EXTENDED TO OCTOBER 30, 2015. Applied to Approved Printed: Wednesday, October 14, 2015 10:12:53 AM 1 of 6 SYSTEMS ADDItIONAL NOTES . CHRONOLOGY TYPE : STAFF NAME rHROINIOLOGY ACTION DATE ` COMPLETION DATE PLAN CHECK COMMENTS FROM CONSULTANT ARMEN ALTOUNIAN 12/17/2014 12/17/2014 APPROVED FROM YOUNG ENGINEERING. RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 10/1/2014 10/1/2014 RECEIVED PLAN CHECK PICKED UP PHILIP JUAREZ 10/31/2014 10/31/2014 PLANS PICKED UP BY GABRIEL RIOS SENT TO PLAN CHECK KAY HENSEL 12/5/2014 12/5/2014 STRUC TO YOUNG - DUE 12/19/14 CONSULTANT TELEPHONE CALL ARMEN ALTOUNIAN 12/18/2014 12/18/2014 LEFT A VOICE MAIL ON GABRIEL RIGS PHONE. PLANS APPROVED AND READY FOR PICK UP. TELEPHONE CALL JIM JOHNSON 10/1/2014 10/1/2014 CALLED APPLICANT TO PICK UP PLANS FOR CORRECTIONS Printed: Wednesday, October 14, 2015 10:12:53 AM 1 of 6 SYSTEMS Printed: Wednesday, October 14, 2015 10:12:53 AM 2 of 6 SYSTEMS • • • CONDITION' DATE DATE DATE A ACCOUNT QTY sr AMOUNT PAID+ PAID DATE RECEIPT # CONTACT METHOD' PAID BY STATUS REMARKS NOTES TYPE ADDED. REQUIRED _ SATISFIED . By READY TO ISSUE JIM JOHNSON 10/1/2015 10/1/2015 PENDING 101-0000-42600 1 CHECKLIST PROCESSING CONTACTS NAME TYPE NAME M ADDRESSI .' CITY STATE ZIP - PHONE FAX: - EMAIL APPLICANT GABRIEL RIOS 49901 CINNEBAR COACHELLA CA 92236 (760)485-7431 OWNER RW REAL ESTATE INC P 0 BOX 447 LA QUINTA CA 0 (760)485-7431 Printed: Wednesday, October 14, 2015 10:12:53 AM 2 of 6 SYSTEMS FINANCIAL INFORMATION DESCRIPTION .x A ACCOUNT QTY sr AMOUNT PAID+ PAID DATE RECEIPT # , .CHECK # METHOD' PAID BY LTD . By PLAN CHECK/PERMIT EXTENSION 101-0000-42600 1 $97.17 $0.00 PROCESSING Total Paid for ADMINISTRATIVE: $97.17 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $6.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $6.00 $0.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 DIF - COMMUNITY 254-0000-43200 0 $129.00 $0.00 CENTERS DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 DIF -PARK 256-0000-43200 0 $40.00 $0.00 MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 DIF - STREET 255-0000-432000 $116.00 $0.00 MAINTENANCE Printed: Wednesday, October 14, 2015 10:12:53 AM 2 of 6 SYSTEMS ` :,-,DESCRIP,�1Opi1-i,-,. ACCOI INT -.QTY- -.AMOUNT, PAID.i PAID DATE RECEI PT # PAID BY' CLTD DIF - TRANSPORTATION 250-000043200 0 $2,842.00 $0.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $0.00 TEMP POWER SERVICE 101-0000-42600 0 $16.92 $0. . 00 PC Total Paid for ELECTRICAL: $41.09 $0.00 RESIDENTIAL, EA 101-0000-42403 .0 $24.66 .$0.00 ADDITION 1,OOOSF RESIDENTIAL, EA 101-0000-42600 0 $10.16 $0.00 Ar ADDITION 1,OOOSF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,OOOSF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 RESIDENTIAL PRECISE GRADING - CUSTOM 101-0000-42408 0 $36.26 $0.00 HOME LOT <=7KSf RESIDENTIAL PRECISE GRADING - CUSTOM 101-0000-42600 0 $36.26 $0.00 Total Paid for GRADING: $72.52 $0.00 101-0000-4240Z 0 $35.75 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $23.83 $0.00 SOR PC EXHAUST HOOD 101-0000-42402 0 $11.92 $0.00 EXHAUST HOOD. PC 101-0000-42600 0 $4.77 $0.00 Printed: Wednesday, October 14,ZO15lO:1Z:53AM 3of6' .. .. DESCRIPTION ri•• ACCOUNT ise'. CITY'AMOUNT z �. ,t ' PAID- rrrrrwuwrrwwYw; PAID'.DATE . P_.6 :'�'�`�"Mi""M', > RECEIPT `# "�wY°'I"`. CHECK #;' �' METHOD PAID BY �'�CLTD'. "�.'.,!�". . a -BY FURNACE 101-0000-42402 0 $35.75 $0.00 FURNACE PC 101-0000-42600 0 $23.83 $0.00 VENT FAN 101-0000-42402 0 $35.76 j $0.00 VENT FAN PC 101-0000-42600 0 $14.31 $0.00 Total Paid for MECHANICAL: $185.92 $0.00 MULTI -SPECIES _ RESIDENTIAL 8.1-14 101-0000-20310 0 $541.00 $0.00 UNITS - 2015 UPDATE Total Paid for MULTI -SPECIES RESIDENTIAL: $541.00 $0.00 - NEW CONSTRUCTION 101-0000-42400 0 $524.09 $0.00 PERMIT Total Paid for NEW CONSTRUCTION PERMIT: $524.09 $0.00 NEW CONSTRUCTION 101-0000-42600 0 $700.00 $700.00 9/11/14 111111 3089 CHECK RW REAL ESTATE INC SKH PLAN CHECK NEW CONSTRUCTION 101-0000-42600 0 $343.86.` $0.00 PLAN CHECK Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,043.86 $700.00 BACKFLOW DEVICE 101-0000-42401 0 $11.92 $0.00 BACKFLOW DEVICE PC 101-0000-42600 0 $4.77 $0.00 BUILDING SEWER 101-0000-42401 0 $11.92 $0.00 BUILDING SEWER PC 101-0000-42600 0 $11.92 $0.00 FIXTURE/TRAP 101-0000-42401 0 $131.12 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $131.12 $0.00 GAS SYSTEM, 5+ 101-0000-42401 0 $35.75 $0.00 OUTLETS GAS SYSTEM, 5+ 101-0000-42600' 0 $23.83 $0.00 OUTLETS PC Printed: Wednesday, October 14, 2015 10:12:53 AM 4 of 6 SYS TEh1S DESCRIPTION ACCOUNT QTY AMOUNT _ PAID PAID DATE RECEIPT # _ __ _ CHECK # _ _ W _ _ METHOD _____ ._. __ __ PAID, BY --- __ CLTD, WATER HEATER/VENT 101-0000-42401 0 $11.92 $0.00 WATER HEATER/VENT 101-0000-42600 0 $7.15 $0.00 PC WATER SYSTEM 101-0000-42401 0 $11.92 $0.00 INST/ALT/REP WATER SYSTEM 101-0000-42600 0 $11.92 $0.00 INST/ALT/REP PC Total Paid for PLUMBING FEES: $405.26 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 $16.80 $0.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $16.80 $0.00 SINGLE FAMILY 224-0000-20320 0 $1,837.44 $0.00 DETACHED Total Paid for TUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:$700.00 7-::RIESULT SEQID INSPECTION TYPE ; . ;INSPECTOR SCHEDULED CO7DATE- FINAL" : REMARKS NOTES DATE.: PARENT PROJECTS Printed: Wednesday, October 14, 2015 10:12:53 AM 5 of 6 SYSTEMS Printed: Wednesday, October 14, 2015 10:12:53 AM 6 of 6 r° SYS TEidS BOND INFORMATION Attachment Type- SAME PLAN ELEVATION AS BRES 1108. OK IN THIS OWNER WALLY - PATHNAME SUBDIR ETRAKIT ENABLED. AREA AS BETWEEN A SANTA FE AND OLDER PLANNING NESBIT 9/11/2014 9/25/2014 9/19/2014 COMPLETED COVE CK - OK HOME ON LARGE LOT. HOUSE BEHIND IS LOWER 0 DOC 10/1/2015 ' ANGELICA ZARCO INVOICE INVOICE 10-1-15.pdf AND THIS PLAN MINIMIZES THE HEIGHT IMPACT. NON-STRUCTURAL ARMEN 9/12/2014 10/2/2014 9/25/2014 REVISIONS REQUIRED 1ST PLAN CHECK RFC. DOC ALTOUNIAN JIM JOHNSON 1109.pdf 1109.pdf 0 STRUCTURAL ARMEN 9/12/2014 10/2/2014 10/1/2014 REVISIONS REQUIRED BACK FROM YOUNG ALTOUNIAN 9/30/14 NON-STRUCTURAL ARMEN 12/5/2014 12/19/2014 12/9/2014 APPROVED 2ND REVIEW APPROVED ALTOUNIAN KATHRYN STRUC TO YOUNG -DUE 12/19/14 STRUCTURAL 12/5/2014 12/19/2014 12/18/2014 APPROVED 2ND REVIEW SAMUELS APPROVED Printed: Wednesday, October 14, 2015 10:12:53 AM 6 of 6 r° SYS TEidS BOND INFORMATION Attachment Type- CREATED OWNER DESCRIPTION, - PATHNAME SUBDIR ETRAKIT ENABLED. N/5 IST REVIEW 54-310 AVENIDA DOC 9/25/2014 ARMEN ALTOUNIAN COMMENTS.docx OBREGON.docx 0 DOC 10/1/2015 ' ANGELICA ZARCO INVOICE INVOICE 10-1-15.pdf 0 SCHOOL FEES BRES2014- SCHOOL FEES BRES2014- DOC 10/1/2015 JIM JOHNSON 1109.pdf 1109.pdf 0 Printed: Wednesday, October 14, 2015 10:12:53 AM 6 of 6 r° SYS TEidS Building Owner PW j �. Mailing 1 Address 17�J) t:Z111Z L4_ iei Contractor Adress & Classif. I Lic. # Hrcn., tngr., s Designer 1 Address Tel ��ic►i Ghrt�c'� �1(��3�- I Ci Zip State 1 _ IrG_ 47 -7!%/Lic. # [1061 P.O. BOX 1504 APPLICATION ONLY 5-495 CALLE O LA QUINTA, CALIFORNIARNIA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city orcounly which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signedstatement that he is licensed pursuant to the Provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) r Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. V-5 OCC. GRP. A.P. Number 1_1 ! — 2o -L :ii>'2_ Legal Description i Project Description =-5j Ind a Ft. !� 2 No. d No. Dw. 1 Stories Units 1 t Add ❑ Alter ❑ Repair O IEstimated Valuation Zi Demolition O PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE — Issued by: Validated by: _ Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE CERTIFICATE OF COMPLIANCE a%%!Eo 4, oy� cyc Desert Sands Unified School District o BERMUDA DUAES •C 47950 Dune Palms Road RANgtO M1RAGE,� - 1"o INOIAB! WELCS' y . La Qunita CA 92253 ��A°�Y Date:, 10/14/2015 ' oioA"i�� ' No.: 15-00045-1 (760)771-8515 Owner: RW Real Estate, Inc. Email: Address: 54310 Avenida Obregon Jurisdiction: La Quinta. City: La Quinta -Tract #: Type: Single Family Residential Lot # Street No. Street Name Sq. Feet APN 54310 Avenida Obregon 1992 774-242-002 Comments: Permit No. At the present time, the Desert Sands Unified School District does not collect fees'on garages/carports; covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.36 X 1992 S.F. or $6,693.12 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Rabobank/Ish Coronet Check No.: 008005676 Bank Name/Recipient of Certificate Telephone: 760-578-3367 Funding: Residential By Dr. Gary Rutherford Superintendent Fee Collected/ xe ted by: Kelly Jones Amount Quei $5;69_3.12 �� Original Payment' Rec'dJ0.00 New Payment 4ec'd: $�,6�µ3.12 v Over.%l�hder: $0.00 h,.�_ NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the.,fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them'on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. LIST'OF ?!Fd:c.:3'— -`C'y:. •' w a'vrW<' °T li`5: ;"' r ° j'C'>:7' w+ -, y�., '.. •"`'i „ �'w x b s,9^v, h :. ,� � RETURNED SENTvQATEDATE DUES+DATE z CONiTACT STATUS REMARKS S}: 4i (''Y h p hoz ,, 1 '�''•SX FTYPE '7Riv;Srmb.".t l .34=u�+a+`r.4�ah='F.� Z ,i , vvZ a `. mc%d,'A"4r'.k 1 . "k.'"i... Review Group: BLDG 1ST (3WK) "9/11/2014 9/19/2014 9/25/2014 PLANNING . ' . WALLY NE,SBIT T. COMPLETED COVE CK - OK C®,VE CHECKv +i=, ; sir i ASSIGNED WN 9.16" i;. ;,,�}l�Nwii� �3 3 6 � � �� � �' �i hr': i {�-' � '' >✓ � � ' � ' r i � l� i�,.i� ��.�'�:�,r.��j P �; �' ?> 'fix• � � 2. '.3 - jj� .S'�"#� �i � ';�ip�. a'i,.�'Ai; �ja t ' a � � ; . i` 1' ;; L "�v SAM;E�PLAN ELEVA%TIIONa'ASiBRESti�1Gl08�OK�IN-TiHIS F � �" �r�2 i3,i�Li:�� �,�i: + I' a v�7` � r^'� T:I' ti}:Y. �, ''�'.� ,�p� � �! � s , • ml., .,, +.w' � � � � 3' � �[;�a � i n v._n „u� k; •���A2�� Mj {"!'�#�� s � k "� I� nC1,> , �'r �, � w�' I'.� . N�}3 ,. t! . � F. M� �+Y N �.... 1,�1 ARE�A�AS.BE'TWEENI;A-SANTA`�PEK�AND ALDER HOIVIE00 N IA'RGEi.LO(T. HOUSE�_B_H1ND IS LO,WER.A. N� TIiiSPLANMINIIVIIZES fHE��HEIGFITIMPACT. �!�',ir. .n ..rad" i"i�i�>, x`.13.' •!' '� �"i (i,�'.. ani: .i •!'!!,. :�73' F:,�IJ�. '.1 ., .p .. ,i�,. ,:„y., a ° ) W. II ` '' r 9��i�F a . •' • , • gin„ 6� u.'iii� ;,;i;, � ,m ai:.iiAd,i'„i... ,�:vi:'�=`,�i��".�."rl�?GL�#i},1G',f�S��iA,`�:'J.ii�r�L 9/12/2014 NON-STRUCTURAL. : pp n Y, � �, �!� i 'P' �,i� �'i��l� �}, y'`5' •J �; � ��� 3 '� � �,�giC'y'i�� �� 3 �W.l !ir iii �, ��� 1'�� ? i ia��' 7, 3 i t ?!�},,', P d�i 9/12/2014 10/2/2014 STRUCTURAL` BUILDING BUCKET _ _� W h 4+B '}� ”. 1 ® YOUNG ENGINEERING. .a a 1' Letter of Transmittal To: City of La Quinta Today's Date: 12-17-14 78-495 Calle Tampico City Due Date:' 12-19-14 La Quinta, CA 92253 Project Address: 54-310 Avenida Obregon Attn: Kay Plan Check #: BRES 2014-1109 ' Submittal: ❑ 151.. ❑ 4th ® -2"d ❑ 5th r _ ❑ 3rd ❑ Other: '. we are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup 4 r Includes: # Of Descriptions: Includes: # Of Descriptions: . Copies: Copies: ®' 2 Structural Plans ❑ - Revised Structural Plans ® 1 Structural Calculations' - ❑ �* _ Revised Struct. Calcs ® Truss Calculations Floor 1 and Roof ' ❑ Revised Truss ❑ Soils Report y ❑ - Revised Soils Report ® 2 Structural Comment List/ Responses ❑ Approved Structural Plans ❑ Redlined Structural Plans ❑ .' Approved Structural Calcs r. ❑ Redlined Structural Calcs r ❑ Approved Truss Calcs ❑ Redlined Truss Calcs r ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. - r f-'41_ R`p I V If you have any questions, please call. Time =.75 HR DEC 7 Z014 This Material Sent for: CITY OF LA•Q0INT•q . r El Your Files"OMMUNI7Y DEVELOWEP'per Your Request ❑ Your Review ❑ 'Approval ti ❑ Checking _ ❑ At the request of: Other: ❑ By: Kathryn Samuels ' Palm Desert Office: ® .(760) 772-5107 Other: ❑ Plan Submittal Job Site Building Permit Number. Project Description: SFR Exempt: 0 (Materialsmay contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Owners Name Number, Sheet, or PO Box City, State, Postal Code Owners Phone Number Owners E -Mail Address Project Managers Name Project Managers Phone Number Project Managers E-mail Address 10/6/2015 54310 Avd Obregon .. Pepe Builds, LLC PO Box 447 La Quinta, Ca 92247 Ish 760-775-1234 coroneloffice0comnetent com Builder/Contractor Coronet Enterprises Number, Street or PO Box1 42760 Madlo St. City, State, Postal Code I Indlo, CA 92201 Project Square City Approval By Date of City Approval 1,992 Totals: Recycle Trash Projected Diversion: 6.7 3.81 63.7° 1 understand h is the property owners responsibigty to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste Is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is Issued In the name of the property owners) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property, cwr er(s) and the owner retains legal responsibility for ensuring that.the provisions of the DMP are adhered t The prope owner(s) and general contractor shall be kept informedof the diversion progress through bl-rAonthl deports. f self -hauling all refuse material from this project site must be taken to an approved recycler or transfer i ' 1 Owner / Developer / Project Manager / Superintendent Date To Be Discarded: Product Tons Trash 3.78 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Bdck/Block 0.00 Recyclable Plaster 0.40 Cardboard 0.66 Recyclable Scrap Metal 0.00 Commingled 0.00 Recyclable Tile (floor) 0:34 Concrete 0.18 Recyclable Tile (roof) 0.00 Drywall 0.12 Recyclable Wood 1 4.98 Donated / Reuse* 0.00 Recyclable Landscape Debris 0.00 'Describe Items Totals: Recycle Trash Projected Diversion: 6.7 3.81 63.7° 1 understand h is the property owners responsibigty to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste Is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is Issued In the name of the property owners) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property, cwr er(s) and the owner retains legal responsibility for ensuring that.the provisions of the DMP are adhered t The prope owner(s) and general contractor shall be kept informedof the diversion progress through bl-rAonthl deports. f self -hauling all refuse material from this project site must be taken to an approved recycler or transfer i ' 1 Owner / Developer / Project Manager / Superintendent Date REr,ORDING REQUESTED BY: Order No. Escrow No. Parcel No. 774-242-002 AND WREN RECORDED MAIL TO: 2015-0447954 10/09/2015 03:37 Pig. Fee: $ 18.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Rldana Assessor-County lli9W IClerk-Recorder W,a, MullIII PEPE BUILDS, LLC PO BOX 447 LA QUINTA, CA 92253 R A Exam: J Page DA COR Misc Long RFD 1st Pg Add Pg CertCC 2 I SIZE NCOR SMF NCHG T: GRANT DEED TELE UNDERSIGNED GRANTOR(S) DECLARE(S) THAT DOCUMENTARY TRANSFER TAX IS $0.00 and CITY $ ® computed on full value of property conveyed, or ❑ computed on full value less liens or encumbrances remaining at the time of sale. ❑ unincorporated area: ® La Quints, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, RW REAL ESTATE INC., a California Corporation hereby GRANT(S) to PEPE BUILDS, LLC the following described real property in the County of Riverside, State of California Lot 4 i 266 of Santa Carmelita at Vale La Quinta Unit No. 24, in the City of La Quinta, County of Riverside, State o Cal' a, as shown by Map on File in Book 19, Page 44 and 45 of Maps, Records of Riverside County. Date Septe er28,2015 Joseph anto, Anotary public orotherofficL•comriet,rgthis certificate Ano verifies only the identity of :^e ::•racial who signed the tarypublicorolheroHicercomplelingth(scerliGcate document to which this cenri�c�,.: �s attached, and not i verifiesonlytheidentityofthe indmdualwho �gnedthe �efnRhtuhtess,accuracyorvat�dnyofthatdacument t� document to which this certificate is attached, and not STATE OF CALIF �hhriness,accuracy,orvafxif of that document COUNTYOFUu?�" �l/�� }S.S. } OnOt'Zq—qQ6 before m V personally appeared who proved to me on the basis of satisActory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. J. HATHAWAY Signa (Seal) r(77 Comtnisaian # 2085517 I JA ti z J Y I Nataryr PUE11a - Ciumnia D J. HATHAWAY z ��vyj Riverside County Commission # 2085517 Z Comm. Ex fres Nov 7.2ott .� Notary Public - California s i Riverside County My comm. Expires Nov 7.2018+ Mail Tax Statement to: SAME AS ABOVE or Address Noted Bdow ',J.. , , . S DOC #2015-0447954 Page 2 of 2 OF III,/ PETER ALDANA Recorder P.O. Box 751 COUNTY OF RIVERSIDE Riverside, CA 92502.0751 ASSESSOR -COUNTY CLERK -RECORDER (951)486-7000 www.riversideacr.com R � .cb�TraS�`~ CERTIFICATION Pursuant to the provisions of Government Code 27361.7, 1 certify under the penalty of perjury that the following is a true copy of illegible wording found in the attached document: (Print or type the page number(s) and wording below): Date: 0`6- - Gy 6 Signature: i ) I - 11 , � 1 11 1 V24 -j( Print Name: 4-OMaWaA4 ACR 601 (Rev. 09/2005) Available in Altemate Formats .r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 15:38, Wed, Dec 23, 2015 Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CFI R -PRF -01 Page 1 of 9 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Single Family Residence 03 This building incorporates one or more Speciaf Feat�uresEshowi below.–. 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 54310 Avenida Obregon Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 1992 15 Number of Zones 1 16 Slab Area (ft2) 1992 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 17.4% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates featuresGthat require field°testing and/orverificatiornby a.certifiediHERS rater underthe supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Speciaf Feat�uresEshowi below.–. 05 06 07 Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 a HERS Provider: CaICERTS inc. Report Generated at: 2015-12-23 15:40:18 - r ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.23 5.00 -0.77 -18.2% Space Cooling 103.15 103.59 -0.44 -0.4% IAQ Ventilation 1.12 1.12 0.00 0.0% Water Heating 11.87 10.49 1.38 11.6% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 120.37 120.20 0.17 0.1% Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 a HERS Provider: CaICERTS inc. Report Generated at: 2015-12-23 15:40:18 - r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Family Residence Calculation Date/Time: 15:38, Wed, Dec 23, 2015 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • —None — ENERGY DESIGN RATING ts1sIP-fl This is the sum of the annual TDV energy consumption;for energy use componentiOnciuded in-theperformance complianee approach for-the-Stand'ard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not,regulated by Title 24, Part,6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. ` 1 f L� rA > T_ i 1 11%� it i; t_�i ice: r Reference Energy Use Energy Design Rating MarginPercent Improvement Total Energy (kTDV/f2-yr)* 168.20 168.03 0.17 0.1% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (f:2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 1992 1 3 1 0 1 Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 201512-28 10:01:54 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datelfime: 15:38, Wed, Dec 23, 2015 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CFI R -PRF -01 Page 3 of 9 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Housel 1992 9 DHW Sys 1 Gross Area (ft2) OPAQUE SURFACES 01 02 ,- %A (TA k 9 04', ir 051 t 4 ` �60 0 06 07 08 Name Constructiontt�;;Type �y^�q RoofRlse� 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Front Wall Whole House R-21 Wall 0 Front 1300 171.999 90 Left Wall Whole House R-21 Wall 90 Left 300 40 90 Rear Wall Whole House R-21 Wall 180 Back 1300 28.4976 90 Right Wall Whole House R-21 Wall 270 Right 300 105.506 90 Roof Whole House _ _ R-38 Roof Attic 1992 ATTIC 1, • , �! 01 02 ,- %A (TA k 9 04', ir 051 t 4 ` �60 0 06 07 08 Name Constructiontt�;;Type �y^�q RoofRlse� Voof7Reflectanc@' f Roof Emittance Radiant Barrier Cool Roof Attic Whole House Attic RoofWhole House Ventilated 0 0.1 0.85 Yes No Registration Number: 215-N6511038A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-12-28 10:01:54 Report Version - CFIR-08252015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:38, Wed, Dec 23, 2015 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CFI R -PRF -01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli or Area (ft) U -factor SHGC Exterior Shading Window Window Front Wall (Front -0) 4.9 10.0 0.837 41.0 0.40 0.30 Insect Screen (default) Window 2 Window Front Wall (Front -0) 6.0 10.0 1 60.0 0.40 0.30 Insect Screen (default) Window 3 Window Front Wall (Front -0) 4.5 10.0 0.911 41.0 0.40 0.30 Insect Screen (default) Window 4 Window Front Wall (Front -0) 3.9 10.0 0.769 30.0 0.40 0.30 Insect Screen (default) Window 5 Window Left Wall (Left -90) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) Window 6 Window Left Wall (Lek -90) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) Window 7 Window Rear Wall (Back -180) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 8 Window Rear Wall (Back -180) 9.0 1.2 0.972 10.5 0.40 0.30 Insect Screen (default) Window 9 Window Rear Wall (Back -180) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 10 Window Rear Wall (Back -180) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 11 Window Right Wall (Right -270) 1.9 9.0 0.936 16.0 0.40 0.30 Insect Screen (default) Window 12 Window Right Wall (Right -270)43.0„j 8.0 1 24.0 0.40 0.30 Insect Screen (default) Window 13 Window n Right Wall (Right=270)0 !' R'. J�' 3.0 1.0 f 1� , ,0--3.0 0.40 0.30 Insect Screen (default) Window 14 Window �'' Rig6t Wall (Right -270) _ y i' _� 1 L 5.0 t1:5 1 1X7:5, 0.40 0.30 Insect Screen (default) Window 15 Window Right Wall'(Right-270)> c- 5;0-A _1 5;1� � 7.5 0.40 0.30 Insect Screen (default) Window 16 Window Right Wall (Ri6ht-270) 5.0 1.5 _ 1V 7.5 0.40 0.30 Insect Screen (default) Window 17 Window Right Wall (Right -270) 5.0 8.0 1 40.0 0.40 0.30 Insect Screen (default) Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:38, Wed, Dec 23, 2015 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CFI R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 4 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 16 0.1 X16 n 16 � 0_ . -�_0 0. 0 0 0 0 0 0 Window 12 16 0.1 16 �16 �t0 �,1� } 0 ou r -2�N 0 0 0 0 0 0 Window 13 16 '���'q.1 ��_16 16_-, * ! Ot t i 0� !r Oil 1` Ifo ,1 0 0 0 0 0 Window 14 2 1 t 12 r- 2 i- r0 1, �e-.0 i t O -y t-- 0n 0 0 0 0 0 Window 15 2 0`1 2 "' 2 0 "0 0`' - 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datelrime: 15:38, Wed, Dec 23, 2015 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CF1 R -PRF -01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R -value Winter Design U -value Assembly Layers Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.65 43000-Btu/hr 0 0 • Cavity / Frame: no insul. / 2x4 Top Chrd Attic RoofWhole House Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. Roof Deck: Wood Siding/sheathing/decking none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 • Exterior Finish: Wood Siding/sheathing/decking Ceilings (below • Inside Finish: Gypsum Board R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Cavity/Frame: R-9.1 /2x4 Over Floor Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade Whole House rf'�' tf f�1992 ? (���' `1( '(('450 s None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION ��` � () L`� z U t<j U " a te/ 6 U tf 011: 1-4 F7 02 { i ) .Os R 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys'l - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.65 43000-Btu/hr 0 0 Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:38, Wed, Dec 23, 2015 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CFI R -PRF -01 Page 7 of 9 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point of Use Recirculation Central DHWControl Distribution DHW Sys 1 - 1/1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Cooling Component 1 SplitAirCond 12.5 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Whole Housel Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 C_ntrlFurnace - Fuel -fired central furnace 80 AFUE Ir iY HVAC - COOLING UNIT TYPES i*� l� i 01 02�' �� 03�` _ _ �04� - — - US . 06 07 Name _ Efficiency L% t +1✓ #-- Verified SEER Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Multi -speed Compressor HERS Verification Cooling Component 1 SplitAirCond 12.5 15 Not Zonal Single Speed Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 y DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1 -hers -dist Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R -PRF -01 Project Name: Single Family Residence Calculation Date/Time: 15:38, Wed, Dec 23, 2015 Page 8 of 9 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Waft Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-6ers fan — Required 0.58 a+ IAQ (Indoor Air Quality) FANS 01 '402 arty � 003 U U -tt :V ! 04' 11 ! 05 ' 06 Dwelling Unit IAQ CFM r '-- `IAQ WattFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 49.92 0.25 Default 0 Required Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-23 15:40:18 v CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation DatefTime: 15:38, Wed, Dec 23, 2015 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence Lot 10 Avenida Carranza.xml CFI R -PRF -01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Gabriel Rios f44"109A'01: Company: Signature Date: Rios Designs 2015-12-28 10:01:54 Address: CEA/HERS Certification Identification (If applicable): 49-901 Cinnabar Lane N/A City/State/Zip: Phone: Coachella, CA 92236 760-485-7431 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of 1 Regulations. 3. The building design features or system design features identified. on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted "to the enforcement agency£for approval with -this building permit application. Responsible Designer Name:40441ib Responsible Designer Signature: zse�ia' Gabriel Rios ��rG Company: p Rios Designs Date Signed: 2015-1-2-28 10:0�1:54� Address: License: 49-901 Cinnabar Lane N/A City/State/Zip: Phone: Coachella, CA 92236 760-485-7431 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N6511038A-000000000-0000 Registration Date/Time: 2015-12-28 10:01:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-12-23 15:40:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 1 of 9 GENERAL INFORMATION 01 Project Name Single Family Residence '02 Calculation Description Title 24 Analysis 03 This building Incorporates one or.`more Special Features shown.below 03 Project Location 54640 Avenida Carranza, 54310 Avenida Obregon 04 A City La Quinta 05 Standards Version Compliance 2014 as Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (65 1) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1992 15 Number of Zones 1 16 Slab Area (FT 2) 1992 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FTZ N/A 21 Glazing Percentage (°k) 15.4% COMPLIANCE RESULTS'""" -r 01 Building Complies with Computer: Performance 02 This building Incorporates features that'require.field testing and/or verification bya certified HERS .rate7zunder the supervision of a CEC-approved HERS provider. 03 This building Incorporates one or.`more Special Features shown.below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard (kTDV/ft) Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.70 4.33 -0.63 -17.0% Space Cooling 104.49 105.74 -1.25 -1.2° IAQ Ventilation 1.12 1.12 0.00 0.0°/ Water Heating 12.58 10. 2.09 16.69/6 o Photovoltaic Offset ---- ® f t 0.0� d{ - --oil Compliance Energy Total 121.89 ING S�F r U X11 0.200 Registration Number: 214-N0147237A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance L DR Cp ����� -� . . N E Y Ak Registration Date/Time: 2014-12-0222: . HERS Provider: Report Version - CF1R-10172014-651 %.=./ o LU Ca10ERTS ince Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Ducts with high level of Insulation a Window overhangs and/or fins CF1 R -PRF -01 Page 2 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAO mechanical ventilation Cooling System Verifications: • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications. «M Mir, • _None — �-` •-�-`M'. � `"`"'..-�4 • ,�"��"` .+''`l,': ENERGY DESIGN RATING This is the sum of the annual TDV energy consurnption'for energy';use components -included in the performance compliance a' proach_for: the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components'nof regulated.'by Titl® 24; Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy: t)esi n Rating ' : Margin Percent Improvement 9 Total Energy (kTDV/f2)• 169.72 169 51 0.21 0.1% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 1992 1 3 1 0 1 Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: • CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datelrime: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 3 of 9 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Houses 1992 11 DHW Sys 1 Gross Area (ft2) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth. Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall Whole House R-21 Wall 270 Left 1000 171.999 90 Left Wall Whole House R-21 Wall 0 Back 1000 40 90 Rear Wall Whole House, R-21 Wall 90 Right 1000 28.4976 90 Right Wall Whole House :=`:>,, R-21 Wall 180 Front 1000 65.5056 90 Roof Whole House R-38 Roof Attic 1992 ATTIC ,urzRL � 501 02 . 07 ` . Name r': Construction .« Roof Rlse rrt r;F Cons q� � �!.,;� � Roof Reflectance 'T Roof Emittance Radiant Barrier Cool Roof Attic 1 "Att" Aoorbons� y ° 0 0.85 Yes No Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Family Residence _ Calculation Datelrlme: 15:03, Tue, Nov 25, 2014 Page 4 of 9 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type - Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (W) 1.14actor SHGC Exterior Shading Window Window Front Wall (Left -270) 4.9 10.0 0.837 41.0 0.40 0.30 Insect Screen (default) Window 2 Window Front Wall (Left -270) 6.0 • 10.0 1 60.0 0.40 0.30 Insect Screen (default) Window 3 Window Front Wall (Left -270) 4.5 10.0 0.911 41.0 0.40 0.30 Insect Screen (default) Window 4 Window Front Wall (Left -270) 3.9 10.0 0.769 30.0 0.40 0.30 Insect Screen (default) Window 5 Window Left Wall (Back -0) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) ' Window 6 Window Left Wall (Back -0) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) " Window 7 Window Rear Wall (Right -90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 8 Window ,,Rear Wall (Right -90) 9.0 1.2 0.972 10.5 0.40 0.30 Insect Screen (default) Window 9 Window Rear Wall (Right -90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 10 Window , Rear Wall (Right -90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 11 Window Right Wall (Front-180).....d/.k .reJ�yu•s. 1.9 '4✓.Nlf' may. 9.0 :y ^�:�. 0.936 16.0 0.40 0.30 Insect Screen (default) Window 12 Window' r = Right Wall (Front 180) -",• 43.0:: 1 24.0 0.40 0.30 Insect Screen (default) Window 13 Window •-. Right Wall (Front �180)� i '.•? 3Y0=. 1 0 �;1 }.3.0 0.40 0.30 Insect Screen (default) Window 14 Window.{ Right Wall.(Front-180) �� , 5 0';` 1 5� r1 7.5 0.40 0.30 Insect Screen (default) Window 15 Window Right Wall,(Front=180) R - 5.0 x"1.5 1' 7.5 0.40 0.30 Insect Screen (default) i Window 16. "Window %e r; Right Wall (Front -180) 5.0 1.5 1 7.5 0.40 0.30' Insect Screen (default) Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Attic Roofs Wood Framed Ceiling O.C. Overhang - Roofing: Light Roof (Asphalt Shingle) Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DIstL Bot Up Depth Top Up Dist R Bot Up Window 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 - Window 4 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 1 0 0 0 Window 8 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 9 2 0.1'i. 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 x:16 0.1* a_ ,. 16 16 `' 0 0 $(' :: 0 0 0 0 0 0 0 Window 12 16 < 01': F *j16 :- `16 .. 1 ,0 >' a 0 ; r =.0 0 0 0 0 0 0 Window 13 i x',16 ), 01 .0 0 0 0 0 0 Window 14 2 0 1 7 ...'2 r 2: 0 `` 0 0 0 0 0 0 0 0 Window 15 2' .0 .1 2 2 0 0 0, 0 0 0 0 0 0 Window 16 2 0 1 2 2 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 2x4 Top Chord of - Cavity /Frame: no insul. /2x4 Top Chrd Roof Truss @ 24 in. - Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none - Roofing: Light Roof (Asphalt Shingle) - Inside Finish: Gypsum Board - Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 - Exterior Finish: Wood Siding/sheathing/decking, - Inside Finish: Gypsum Board - Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 - Over Floor Joists: R-28.9 insul. Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datelrime: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1992 16 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type-.. Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS ; r- . ;' t 'N I 'F "7'N 01 02 03 ' ;" .. , ` ; 04 t ," [; s ' '05s . 06 " 07 OB Pipe Insulation F _ '` .4 i r ergy �- Tank Exterior Loss WA WA N/A Tank Volume E Fa'ctoi o Whole Housel Insulation Standby Name Heater Elemeril Type `Tank Type ' (gal) Efficiency Input Rating R -value (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.65 43000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 WA WA WA N/A WA WA HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served Whole Housel Other Heat/Cool Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 1992 Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:3925 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntriFurnace - Fuel -fired central furnace 80 AFUE CF1 R -PRF -01 Page 7 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow.' Eff iciency Verified EER Multi -speed Verified Refrigerant - Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 12.5 15 No No Cooling Component 1 -hers -dist system 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow.' . ,,,,.Airflow Target. Verified EER Verified SEER Verified Refrigerant - Charge Cooling Component 1 -hers -cool Ftequ�red �, . f .. "' ;` 350 rr;y } "fequired. Required Required I, ..,.;.- .Pr'�� „t,,i: ,. r._..,,;. , . .. ,P'.r, ,., ]. s• ,r7. " -.1, , HVAC - DISTRIBUTION SYSTEMS h� / i yf i� "p .f : `3wf••is4d }s F. :. - 01 :02:. r '03. < : 5.. -,.. 04.:; :::05 06 07 08 Name Type' Duct Leakage Insulation R -value Supply Duct ' Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic '" Specified Lower Leakage Target 8 Attic . Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 Duct Leakage Verified Duct Design Low -leakage Name Verification Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System Required 6.0 Not Required Not Required Not Required Required 1 -hers -dist Registration Number: 214-N0147237A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-12-02 22:39:25 Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc._ Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 8 of 9 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM' ': IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 49.92 0.25 Default 0 Required Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Family Residence Calculation DaterrIme: 15:03, Tue, Nov 25, 2014 Page 9 of 9 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ��/ dun O-6 er Joan Hacker Company: Signature Date: Joan Hacker 2014-12-02 09:01:47 Address: CEA/HERS Certification Identification flf applicable): 77810 Las Montanas Road, Suite 201 City/State/Zip: Phone: Palm Desert, CA 92211 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified.on this :Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and'specifications submitted to the enforcement'a_gency for approvatwith. this ,bbil'd'ing permit application. Responsible Designer Name: U.. Responsible Designer Signature,:. Gabriel Rios Company: Date Signed. - Rios Designs 2014-12-02 22:39:25 Address: License: 49-901 Cinnabar Lane na City/State/Zip: C/ / Phone: Coachella, CA 92236 60-485-7431 It r) I —11 O/Ato AP FOR CO OgTF NSTRUC® N /\��sy Digitally signed by CaICERTS. This digital signature is provided in order to secure the content o�'th' e�?ere document an in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 BUILDING ENERGY ANALYSIS REPORT PROJECT: R.W. Real Estate Avenida Obregon La Quinta, CA Project Designer: Report Prepared by: Joan D. Hacker Insu-form, Inc. 77810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211CI�.,Y OF LA C.�UiNTA 760-345-1352 BUILDING &.SAFETY DEPT. APPROVED - FOR CONSTRUCTION Job Number: RECEIVED Date: s SEP 1`12014 9/9/2014- CITY OF LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. Ener Pro 6.3 by Ener Soft User Number. 2655 ID: TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary F EnergyPro 6.3 by EnergySoft Job Number: ID: User Number: 2655 1 2 3 13 16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 Project Location Avenida Obregon 04 A City La Ouinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (650) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT 2) 1992 15 Number of Zones 1 16 Slab Area (FT2) 1992 17 Number of Stories 1 16 Addition Cond. Floor Area NA oA�� Natural Gas Available Yes 20 Addition Slab Area (FT 2) NA Glazing Percentage (°k) 15.4% COMPLIANCE RESULTS d" 01 Building Complies with Computer Performance 4V 02 This building incorporates features that require field testing and/or verifiq&66n by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown beloo O®� Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance EULull G & SAQUINTA FETY DEPT. APPROVED FOR CONSTRUCTION DATE --___8y Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date rime: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 2 of 10 a ; Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/tt2-yr) Design Design Margin Improvement Space Heating 3.70 4.313 -0.63 -17.0% Space Cooling 104.49 105.74 -1.25 -1.2% IAO Ventilation 1.12 1.12 0.00 0.0% Water Heating 12.58 10.49 2.09 16.6% PV Credit 0.00 0.00 North Facing Compliance Total 121.89 121.68 0.21 Space Heating 3.70 -0.80 -21.6% �A150 Space Cooling 104.49 02.93 1.56 1.5% IAQ Ventilation 1.12 1.12 0.00 - 0.0% Water Heating 12.58 0 10.49 ® 2.09 16.6% PV Credit 0.00 0.00 East Facing Compliance Total 121.89 119.04 2.85. 2.3% Space Heating 3.70 3.85 -0.15 -4.1% Space Cooling 104.49 102.67 1.82 1.7% IAQ Ventilation 1.12 1.12 obo 0.0% Water Heating 12.58 e�� 10.49 2.09 16.6% PV Credit = 0.00 ,. 0.00 - South Facing Compliance Total 121.89 118.13 3.76 3.1% Space Heating 3.70 3.74 -0.04 -1.1% Space Cooling 4.04 101.81 2.68 2.6% IAQ Ventilation 1.12 1.12 0.00 0.0% Water Heating 12.58 10.49- 2.09 16.6% PV Credit 0.00 0.00 West Facing Compliance Total 121.89 117.16 4.73 3.9% a ; Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Family Residence Calculation Datefrime: 13:55, Tue, Sep 09, 2014 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml 4EQUIRED SPECIAL FEATURES rhe following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Ducts with high level of Insulation Window overhangs and/or fins PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, requre field verification by a certified HERS Rater. • IAO mechanical ventilation ENERGY DESIGN RATING �� This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use '=Energy t)esign Rating Margin Percent Improvement Total Energy (kTDVtf2)' 169.72 169.5l 0.21 0.1% includes calculated Appliances and Miscellaneous Energy Use (AMEU)_ _�® BUILDING - FEATURES INFORMATION v 01 02 03 1* 04 05 06 07 Zone Name Zone Type Number of Dwelling Zone Floor Area (ftZ) Avg. Ceiling Height Number of Ventilation Number of Water Project Name Conditioned Floor Area (sft) Un" -V- Number of Bedrooms Number of Zones Cooling Systems Heating Systems Single Family Residence 1992 rcv 3 1 0 1 s: IN ZONE INFORMATION 01 02 �� 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Housel 1992 11 DHW Sys 1 �t e®sir Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall Whole House R-21 Wall 270 Right 1000 171.999 90 Left Wall Whole House R-21 Wall 0 Front 1000 40 90 Rear Wall Whole House R-21 Wall 90 Left 1000 28.4976 90 . Right Wall Whole House R-21 Wall 180 Back 1000 65.5056 90 Roof Whole House R-38 Roof Attic _ 1992 ►1aa ATTIC' 01 02 03 X04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 0 p�r 0.1 10.85 Yes INo CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft ) Height (ft) Multiplier Area (W) 1.1 -factor SHGC Exterior Shading Window Window Front Wall (Right -270) 4.9 10.0 0.837 41.0 0.40 0.30 Window 2 Window Front Wall (Right -270) 6.0 10.0 1 60.0 0.40 0.30 Window 3 Window Front Wall (Right -270) 4.5 10.0 0.911 41.0 0.40 0.30 Window 4 Window Front Wall (Right -270) 3.9 10.0 0.769 30.0 0.40 0.30 Window 5 Window Left Wall (Front -0) 4.0 X5.0 1 20.0 0.40 0.30 Window 6 Window Left Wall (Front -0) 4.0 ;j"'5.0 1 20.0 0.40 0.30 Window 7 Window Rear Wall (Left -90) 4.0 1.5 1 6.0 0.40 0.30 Window 8 Window Rear Wall (Left -90) 916, 1.2 0.972 10.5 0.40 0.30 Window 9 Window Rear Wall (Left -90) ; 4.0 1.5 1 6.0 0.40 0.30 Window 10 Window Rear Wall (Left -90) 14.0 1.5 1 6.0 0.40 0.30 Window 11' Window Right Wall (Back -180) `� 1.9 9.0 0.936 16.0 0.40 0.30 Window 12 Window Right Wall (Back -180) 3.0. 8.0 1 24.0 0.40 0.30 Window 13 Window Right Wall (Back -180) 3.0 1.0 1 - 3.0 0.40 0.30 Window 14 Window Right Wall (Back -180) 14,14'5.0 1.5 1 7.5 •0.40 0.30 Window 15 Window - Right Wall (Back -180) 5.0 1.5 11 7.5 0.40 0.30 Window 16 Window Right Wall (Back -180) 5.0 1.5 1 7.5 0.40 0.30 s� w Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Tlme: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 Construction Name Surface Type CoGiructlon Type Framing Total Cavity R -value Assembly Layers 01 02 03 04 05 06 07 08 09 10 11 12 13 14 O.C. none • Roofing: Light Roof (Asphalt Shingle) Overhang Left Fin • Inside Finish: Gypsum Board Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DIstL Bot Up Depth Top Up Dist R Bot Up Window 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 4 10 0.1 10 10 0 0*M' 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 & 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 '$�0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 8 0:1 8 8 0° 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0&P 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 Window 11 16 0.1 16 16 `00 0 0 0 0 0 0 0 0 Window 12 16 0.1 16 16 0 0 0 0 0 0 0 0 0 Window 13 16 0.1 16 1F��� 0 0 0 0 0 0 0 0 0 Window 14 2 0.1 2 & v 0 0' 0 0 0 0 0 0 0 Window 15 2 0.1 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 My OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type CoGiructlon Type Framing Total Cavity R -value Assembly Layers 2x4 Top Chord of • Cavity/Frame: no insul. /2x4 Top Chrd Roof Truss @ 24 in. • Roof Deck. Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 ? R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 • Exterior Finish: Wood Siding/sheathing/decking 12% • Inside Finish: Gypsum Board ® a Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 • Over Floor Joists: R-28.9 insul. Registration Number: Registration Date/Time: CA Building Energy Efficiency Stan�da ds - 2013 Residential Compliance Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datelrime: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 7 of 10 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1992 16 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- r_>m WATER HEATING SYSTEMS 01 01 02 03 04 Name Distribution Type °�� Number of Heaters Solar Fraction (%) DHW Sys 1 Pipe Insulation, All Lines $v - 1 0.0% WATER HEATERS 01 02 03 4 04 05 06 07 08 Name Heater Element Type Tank Type ® Tank Volume (gal) « Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Store. 50 0.65 43000-Btu/hr 0 0 rl� WATER HEATING - HERS VERIFICATION s. 01 02 03 04 05 06 07 Name Pipe Insulation R Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a Na n/a n/a n/a HVAC SYSTEMS , 01 02 03 04 05 06 07 - - Heating System Cooling System .. Distribution Floor Area Name °® System Type Name Ducted Name Ducted System Fan System Served Whole Housel ' Other He i g and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 1992 Component 1 System 1 Registration Number: Registration Date/Time: HERS Provider: - CA Building Energy Efficiency Standards- 2013 Residential Compliance Report'Version - CF111-09042014-650 Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Daterrime: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE CF1 R -PRF -01 Page 8 of 10 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEE Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 12 5 1 No No Cooling Component Ducts located in attic system Attic Attic None 1 -hers -cool IR"A HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow�T'laget Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 0 Required Required Required HVAC - DISTRIBUTION SYSTEMS - 01 02 03 ¢ yp 04 05 06 07 08 Verified Duct Design Name Duct Leakage Verlfic0on Supply Duct Verified Duct Location Return Supply Air Distribution System 1 -hers -dist Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Specified Lamer8 Attic Attic None Air Distribution .. Leakage�rget System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION ` 01 02 law03 04 05 06 • Verified Duct Design Name Duct Leakage Verlfic0on Duct Leakage Target (%) Verified Duct Location Return Supply Air Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required Ar9 HVAC -FAN SYSTEMS o`er 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 `� Single Speed PSC Furnace Fan 0.58 Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Staniiaads - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datefrime: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml z CF1 R -PRF -01 Page 9 of 10 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifledFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAOVentRpt 49.92 0.25 Default 0 Required CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Aut or Signature: Joan D. Hacker Company: Signature Date: Insu-form, Inc. 9/9/2014 Address: 77810 Las Montanas Road, Suite 201 CEA/HERS Certification Identification (If applicable): city/statelZalm Phone: P Desert, Ca 92211 7601345-1352 � RESPONSIBLE PERSON'S DECLARATION STATEMENTt I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility fort a building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate ojCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of W Regulations. 3. The building design features or system design features identified on this Certificate of Comp ance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencylfor approval with this building permit application. Responsible De ' ner ame: 41:4 Responsible Design ' nat e: r' � Company:.,,, v ca Date Signed: m /o Address:.64"W- b, 4 " License: 6 - �® City/State Zip: Phone; .0 Registration Number: ♦� CA Building Energy Efficiency Stan ads - 2013 Residential Compliance Registration Datefrime: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date R. W. Real Estate 191912014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. §150.0(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. 1 50.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below. 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building ro'ect. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pumpisolation valve and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number: 2655 ID: Pege 13 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MFA R Project Name Date R. W. Real Estate 191912014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 1 50.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)l : Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50.0 m 7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 1 50.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)l : Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)l: Any pool or spa heating equipment shall be installed with at least 36° of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing,flow rate piping,filters and valve requirements of §150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency — 20 kHz. §150.0(k)l E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 2655 ID: Page 14 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date R. W. Real Estate 191912014 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet therequirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below, and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time dock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For lovo-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9 130.0 130.2 130.4 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to § 1 30.0 d . §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130. 1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Coinply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoft User Number. 2655 /D: Page 15 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name R.W. Real Estate Date 9/9/2014 System Name Whole House Floor Area 1,992 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 1,029 24,524 2,073 648 Return Vented Lighting 0 Return Air Ducts 1,416 Return Fan 01 Ventilation 0 0 0 0 Supply Fan 0 Supply Air Ducts 1,416 TOTAL SYSTEM LOAD 1 27,355 2,073 PEAK Heating System Sensible Output per System 70,000 23,781 Total Output Btuh 70,000 Output Btuh/ ft 35.1 1,169 Cooling System 0 Output per System 58,000 0 Total Output Btuh 58,000 0 Total Output Tons 4.8 1,169 Total Output Btuh/s ft 29.1 Total Output ft/Ton 412.1 26,118 Air System CFM per System 2,210 HVAC EQUIPMENT SELECTION Airflow cfm 2,210 BDP CO. 561AJ060-• 43,872 5,839 70,000 Airflow cfm/s ft 1.11 Airflow cfm/Ton 457.2 Outside Air°/, 0.0% Total Adjusted System Output 43,872 5,839 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 70,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 2,210 cfm 70 OF 70 OF 105 OF Heating Coil 105 OF i ROOM In 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/63°F 79/63°F 55/54°F _ Outside Air c1 ® SAF 0 cfm Supply 2 0 Fan Cooling Coil BUILDING & � �� 56 154 OF P�V)��� v�T`2P-°k f ROOM OR GO I 79 / 63 OF F � 78 / 63 OF R Ener Pro 6.3 by Ener Soft User Number.., 2655 RunCode: 2014.09-09714:00:35 ID: Pae 16 of 16 Building Materials and Construction services 45-491 GOLF CENTER PARKWAY, INDIO, CA. 92203 0.760-347-3332 F.760-347-0202 CONTENTS .........................PACE TIMBER PRODUCTS INSPECTION (LETTER)..1 ................................ • TPI (GTI) STAMP - SEE PAGE 1 ..................................2 EXPLANATION OF ENGINEERED DRAWING ..................................3 DETAIL FOR COMMON AND END JACKS - 16 PSF ..................................4 DETAIL FOR COMMON AND.END JACKS - 20 PSF ..................................5 SUPPORT OF B.C. (PRESSURE BLOCK) STANDARD OPEN END JACK..................................6 INTERIOR BEARING OFFSET DETAIL ..................................T BEARING BLOCK DETAIL 3 V BEARING ..................................8 BEARING BLOCK DETAM 5 V BEARING ..................................9 UPLIFT TOE -NAIL DETAIL .................................10 LATERAL TOE -NAIL DETAIL .................................11 WEB BRACING RECOMMENDATIONS .................................12 T -BRACE AND L-BRACE .................................13 VALLEY TRUSS DETAIL ..................................14 VALLEY TRUSS DETAIL (CONT'D.) ...............................-15 GABLE DETAIL ..16 •PURLIN PURLW GABLE DETAIL (CONT'D.) ..1T PURLIN GABLE DETAIL (CONT'D.) ..18 PURLIN GABLE DETAIL (CONT'D.)................................... ................................ 19 STANDARD GABLE END DETAIL ..................................20 STANDARD GABLE END DETAIL (CONT'D.) .................................21 STD. REPAIR - MISSING STUD ON GABLE TRUSS ....................................22 STD. REPAIR -BROKEN STUD OAtLE TRUSS . ...�...�........................23 STD. REPAIR - REMOVE CENTER STUD ON GABLE TRUSS .................................24 STD. REPAIR - NOTCH 2X6 TOP CHORD ON GABLE TRUSS .................................25 STD. REPAIR - NOTCH 2X4 TOP CHORD ON GABLE TRUSS .................................26 STANDARD REPAIR DETAIL - 25% .....................................2T FALSE BOTTOM CHORD FILLER DETAIL .................................28 OVERHANG REMOVAL DETAIL .................................29 SCAB APPLIED OVERHANGS .................................30 PIGGYBACK TRUSS CONNECTIONS ............................31 - 34 PLEASE CONTACT 8MC FOR MORE INFORMATION OR. QUESTIONS REGARDING THESE SHEETS PAGE: 0 OF 34 ( T MOER PRODUCTS' Septomber "11, 2.012 To Whom It May Concern: • This is to verify that BMC of Indio, CA is a Subscriber in the. Timber Products Inspection (TP) and Genei'af Testing and Inspection (GTI) Truss Quality Auditing Program. The TP and GTI Truss Quality Auditing Programs are recognized by the Interliational Accreditation Service (IAS) with the assigned number of AA -664. TP and the GTI quality assurance marks have been recognized in the West by the truss i;ndusfry and code jurisdictions since 1969. TP currentky audits truss manufacturing facilities nationwide. TP is conducting unannounced, third parfy audits at BMC of Indio, CA. This facility is currently in good standing in the TP Truss Ouaiity Auditing Program. I3MC`s personnel are authorized to apply the GTI quality mark to trusses that are- manufactured in accordance with the latest revision of the ANSI/TPI Standards. All stariiping takes place at the truss manufacturing facility, under supervision of qualified plant personnel. + If you have questions regarding the status- of any plant in the. TP/GTI Program, please i contact me: on my cell 208.818.7869. I l _. Sincerely, E + TINIIBER-PRODUCTS INSPECTION c i 4�r�- Brian.He'nsley Truss Manager—Western 0ivisio+i j Xc: File I -'i 07ae i 105 SE 1241h Avenue Q P.O. Box. 919 0 1641 Sigman Road Vancouver, Washington 98684 445 Conyers, Georgia 30012 330/449.38410 FAX: 360/449-3953y��e,! �! 770/922-8000 FAX: 770/922-1?_90 � i