Loading...
09-0773 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253 Application Number: 09-00000773 Property Address: 54250 RIVIERA APN: 775-031-059- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 45000 Applicant: Architect or Engineer: ----------------- LICENSED CONTRACTOR'S DECLARATION 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cla B e se No.: 684857 i - Date: Contractor: WNER-BUILDER DECLARATION ' I hereby affirm under penalty o perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed , pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERAI IT Owner: O'KEEFE JOHN/KATHY PO BOX 1092 SOUTHPORT CT SEBRING, FL 06890 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 8/25/09 u tfe_ /= 1 n Contractor: EDWARDS CONSTRUCTION INC, BOB 51455 DESERT CLUB DRIVE LA QUINTA, CA 92253 (760)777-8202 Lic. No.: 684857 209 /�. � -- - --------------7--------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier GRANITE- STATE Policy Number WC 555-61-55 I certify that, in the performance of the work for which this permit is issued, I shall not employ any �Y/abp'1eRrlson in any manner so as to becom subject to the workers' compensation laws of California, agree that, if I should ers' compensation provisions of Section 7Q0 of the Labor Code, shall forth it comply with tho rovisions. Date: 0 Applicant: WARNING: FAILURE TO SECURE WORKS' C PEN OVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PE LTIES AND CIVIL FINES NE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the - conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit cancellation. I certify that I av read this applicatio state that the a nfo rrect. I agree to comply with all city and co ty dinances and state I s relating to i coon, and hereby authorize representatives of this c t en upon the above -me y fo inspection purposes. Date: Signature (Applica A r S� ' Application.Number . . . . . 09=00000773 --'---- Structure Information 486SF CASITA ADDITION/VB/RES-3/CL-A[ENG]----- Other struct info CODE EDITION 2007CBC # BEDROOMS. 1.00 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE 486.00 Permit BUILDING PERMIT Additional desc . Permit Fee. 382.00 Plan Check Fee'.,. 248.30 Issue Date . . . . Valuation . . 45000 Expiration Date 2/21/10 Qty Unit Charge' -.Per Extension BASE FEE 252.00 20.00 6.5000 THOU BLDG 25,001-50,000 130.00 Permit . . . ELECT - ADD/ALT/REM Additional desc Permit Fee . . . 32.01 Plan Check Fee 8.00 Issue Date Valuation -. 0 Expiration Date 2/21/10 Qty Unit Charge Per Extension BASE FEE 15.00-- 486.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY,- 17.01 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 48.00 Plan Check Fee 12.00 Issue Date . . . . Valuation . - . . 0 Expiration Date 2/21/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA. MECH AH <=10K CFM 6.50 2.00 6.5000 ------------------------------------------------------------------------C EA MECH VENT FAN 13.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 36.00 Plan,Check Fee 9.00 Issue Date . . . . Valuation 0 LQPERMIT Application Number . . . . . 09-00000773 Permit PLUMBING Expiration Date 2/21/10 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments `. 486SF CASITA ADDITION/VB/RES-3'/CL A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS OR PROPOSED GATES. 2007 CALIFORNIA BUILDING CODES. August 24; 2009 4:43:07 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 24.83, STRONG MOTION (SMI) - RES 4.50 Fee summary Charged Paid Credited Due ---------- ---------- ---------- --- Permit Fee Total 498.01 .00 .00 ----- 498.01 Plan Check Total 277.30 .00 .00 277.30 Other Fee Total 31.33 .00 .00 31.33 Grand Total 806.64 .00 .00 •806.64 LQPERMiT f Bin # c � 4, ......,..... ' . City of La Quinti -Building: 8L Safety Division P.O. Box 1504, 78 -495 -Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # `�, �� ✓ Project Address: 2� � Owner's Name: A. P. Number: .-77S7-0 1 _1 Address: 5-4-2—SD Legal Description: L44 L -r F,- City, ST, Zip: (..A.. Contractor: ��S COST Telephone: `..�% � `<<y:�;;;>3•::::,>�;�<::>•f}>` Address: Project Description: City, ST, Zip: Telephone:` Z z>?•?<>>:# :as•`:s<<:;> ::.'•<:>; State Lic. # : City Lic. #; AEEIEEM Designer: W l j r C Address: City., ST, Zip:T,;_"O� C Telephone: 7ic7� State Lic. v.:,h<r :k>rr>:;f':{ :>::•.: � <.•:;<• Construction Type: Occupancy:? circle one): New Add'n Alter Repair DemoProject; a Name of Contact Person: Sq: Ft.: �j #.Stories: # Units: Telephone # of Contact Person: RR,5 6 Estimated Value of Project: , APPLICANT: DO NOT WRITE. BELOW THIS LINE. # Submittal Req'd Recd TRACIONG PERMIT FEES Plan Sets Plan Check submitted Item Amount . Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person •A& WONPlan Check Balance. Title 24 Calcs. Plans picked up 22 _ Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for correcti rlss Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up. S.M.I. H.O.A. Approval' Plans resubmitted Grading IN HOUSE:- Revlew,.ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person I p p Pub. Wks. A r PP Date of permit issue School Fees 00, Total Permit Fees ISM CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES r Ln RANCHO MIRAGE !� Date 8/25/09 La Quinta, CA 92253 N INDIAN WELLS No. 30481 (760) 771-8515 d% PALM DESERT LA QUO y �PINOIO yr� O Owner Mr & Mrs O'Keefe APN # , 775-031-059 Address 54-250 Riviera Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Detached Guest House Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 54250 Riviera Unit 2 Unit 3 Unit 4 Unit 5 Comments 486 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 486 S.F. or $1,443.42 ' have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid_ By CC/1st Bank - Ed Randall Check No. 90150 Name on the check Telephone 777-8202 Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected Signatt Payment Recd se,00 - $1,443.42 11vePlunder - NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to AQI* you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting PGA WEST. RESIDENTIAL ASSOCIATION, INC. June 22, 2009 Mr. & Mrs. John O'Keefe 54-250 Riviera La Quinta, CA 92253 Re: 54-250 Riviera — Architectural Variance Submittal — Casita Dear Mr. & Mrs. O'Keefe, The Architectural Committee has reviewed your preliminary submittal for a casita addition. The proposed project is acceptable in concept and architectural compatibility. On June 4h and 9`h, the Committee members were at your unit to visually observe the existing building and yard configuration, relative to the new addition. The following comments apply to your variance application. I . The details and finishes are to match the existing building. 2. The building layout and design is nicely done.: 3. The landscape plans are important to the final appearance and are to match the existing. 4. The information on the gate details 'is lacking and is necessary with the final plans. 5. The final plans are to include the structural and mechanical information. 6. Please ask Rob Pitchford to consider a minor front elevation change. The horizontal offset band to be added at the new elevation to match or complement the existing elevation. 7. Please review the length of the rafter overhang and consider reducing it. 8. Please note this is not a final release to proceed. ' The final plans and City of La Quinta permit are pending. Please contact the Committee if you have any questions. Cordially, Ke y cGalliard Operations Manager For the Architectural Committee cc: Architectural Committee 54-320 Southern Hills, La Quinta, California 92253-5665, Telephone 760-771-1234 FAX 760-771-5125 STRUCTURAL AND CIVIL ENGINEERING DENISE R.'POELTLER, INC. 77.725 Enfield Lane • Unit # 130 • Palm Desert, California 92211 drpfly@aol.com 21 September 2009 Mr. Tom Hartung, Building Director CITY OF LA QUINTA Department of Building and Safety 78495 Calle Tampico La Quinta, CA 92253 RE: O'Keefe Casita Address: 54-250 Riviera, PGA West Subject: Structural Observation Dear Mr. Hartung: I have observed the structural"elements and lateral load path (with exceptions noted below) for the structure referenced above and found them in substantial conformance with the structural documents prepared by my firm. Not observed by me, but inspected by the City Building Inspector: Foundation steel reinforcing, pad footing size and depth, and slab thickness. Roof sheathing nailing. ESS Respectfully submitted, @�Op�OVkpo �q No.33446 * Exp. 6 -3o - to R -2l -off Denise R. Poeltler R.C.E. 33446 0 W.O. 09-147 cc: Mr. Bob Edwards, BOB EDWARDS CONSTRUCTION PHONE (760) 772-4411 • FAX (760) 772-4409 th4g,/ STRUCTURAL AND CIVIL ENGINEERING DENISE R. POELTLER, INC. 77.725 Enfield Lane • Unit # 130 * Palm Desert, California 92211 drpfly@aol.com 12 August 2009 Mr. Tom Hartung, Building Director CITY OF LA QUINTA Department of Building and Safety 78-495 Calle Tampico La Quinta, CA 92253 RE: O'KEEFE CASITA Job Site Address: 56-250 Riviera, PGA West Subject: Truss Acceptance Letter Dear Mr. Hartung: I have reviewed the total deflection, live, dead, and drag loads used for the design of the gang -nail roof trusses prepared by SELECT BUILD (dated 07-30-09), and found them in substantial conformance with the structural documents prepared by my firm. Respectfully submitted, Denise R. Poeltler R.C.E. 33446 W.O. 09-147 cc: Robert A. Pitchford, Designer CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Y V/ - PHONE (760) 772-4411 0 FAX (760) 772-4409 I TITLE 24 REPORT I Title 24 Report for: Mr. & Mrs. John O'Keefe-Casita 54-250 Riviera La Quinta, CA 92253 Project Designer: Robert A. Pitchford, Design & Drafting 77-622 Country Club, Suite O Palm Desert, CA 92211 (760) 346-2856 CITY OF LA OUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION OATS By Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 8/3/2009 AUG 13, 2009 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 1 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary 10 Room Heating Peak Loads 11 Room Cooling Peak Loads 12 EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R J�ba_O'Keefe_Casita (SW) 240 deg Raised Floor Area: 81.312009 oject Title Fuel Type: Natural Gas Slab on Grade Area: Date Riviera—La_Q.uinta Fenestration: Average Ceiling Height: 9.2 Project Address Area: 119 ft2 Avg. U: 0.41 Number of Dwelling Units: Building Permit # � c_ofLDesign_& TMe 24 Ratio: 24.5% Avg. SHGC: 0.37 (760) 200-4780 1 Documentation Author # of Thermostat Telephone Plan Check/Date _EaernvPr Units Zone Type Type CA Cl..mafeZa e-15 HVAC: -1 Field Check/Date Compliance Method 2 —nla Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.99 0.68 2.30 Space Cooling 89.39 86.28 3.11 Fans 12.71 13.81 -1.10 Domestic Hot Water 32.55 32.55 0.00 Pumps 0.00 0.00 0.00 Totals 137.65 133.33 4.31 Percent better than Standard: 3.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: Q Single Family ❑ Addition Total Conditioned Floor Area: 486 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (SW) 240 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 486 ft2 Fenestration: Average Ceiling Height: 9.2 ft Area: 119 ft2 Avg. U: 0.41 Number of Dwelling Units: 1.00 Ratio: 24.5% Avg. SHGC: 0.37 Number of Stories: 1 UILDING ZONE INFORMATION * # of Thermostat Vent ne Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC: -1 486 447 1 nn _Conditioned— —Setback— 2 —nla OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt .Rn.of— Wnnd_ _.8.6_ X028_ _e_38_ a -n n 0-20 -W;;Il— u Qad— X3.3_ 0 069 —R-21 _B=0 0_ x.030 -Wall Wood_ —lab- —0...0.6.9_ —R21 13-0_0_ x.5.0 -_9.0 -W;311— Wnnd_ 208 _0-0.6s R-91 —R -n n 240_ 9.0 Vital] Wood_ —0-0.6.2 —R_91 X0_0- --33Q_go Gains Condition Y / N Status JA IV Reference Location / Comments Mew _02-A28 .C.asita New 0.2A6 fasita New 9.9-A6 C.asita New 09_a6 flasita New 09-A6 Casita 2493127 I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Paae:3 of 12 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R r. & Mrs. John O'Keefe-Casita 8/3/2009 ect Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazinq Type Comments _L Window Rear (NFa 40 --D-MO NERC -0-31 NFRC. 60_ _9.0_ New_ D_ou.ble Non Mefnl Tinted Casita 2 Window Rear (NE) 4.0 0.390 NFRC 0_37 NFRC 60 90 New Double Non Metal Tinted Casita 3 Window Right (SE)_ 3.5 0.720 NFRC 0_39 NFRC 150 90 New Glass Block Casita 4 Window Right (SE) 48.0 0.390 NFRC 0_37 NFRC 150 90 New Double Non Metal Tinted Casita 5 Window Front (SW) 4.0 0.390 NFRC 0_37 NFRC 240 90 New Double Non Metal Tinted Casita 6 Window Front (SW) 4.0 0.390 NFRC 0_37 NFRC 240 90 New Double Non Metal Tinted Casita L Window Front (SW)48 0 0.399 N_EBC-0- 37 NFRC 240 90 New Double Non Metal Tinted Casita 8 Window Left (NW) 3.5 0.720 NFRC 0.39 NFRC 330 90 New Glass Block Casita 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 Bug Screen 0.76 _ Bug Screen 0.76 _ Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN • Run Initiation Time: 08/03/09 08:18:52 Run Code: 1249312732 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 12 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 256 3.50 28 0_98 2 26-A1 New Casita / Slab on Grade Concrete, Heavyweight 230 3.50 28 0_98 0 26-A1 New Casita / Slab on Grade Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 41 None No Insulation 26-A1 New Casita Slab Perimeter 57 None No Insulation 26-A1 New Casita • Run Initiation Time: 08/03/09 08:18:52 Run Code: 1249312732 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 12 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Mrs. John O' Title 8/3/2009 Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -1 Split Heat Pump 8.80 HSPF Split Heat Pump 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -1 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Robert A. Pitchford Deakin & Draftina Address: 77-622 Coue Palm ert C Telephone: (76 r (signatur/ r/ f (date) Enforcement Agency Name: Title/Firm: Address: Telephone: ignature) (date) Title/Firm: Scott Design & Title 24 Address: 77085 M' hi an Dr. Palm DEAert, CA 92211 Telephone: (76"0-47,80 Q (signature) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R ct Title 8/3/2009 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on me aaequacy or me special tusuricarion ano aocumenrauon suomiuea. Plan i Field IThe Roof "R-38 Roof(R.38.2x12.24)" includes a Radiant Barrier. I I I HIGH MASS Design - Thermal Mass: 256 sqft Covered Slab Floor, 3.50" thick at Casita HIGH MASS Design - Thermal Mass: 230 sgft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field he HVAC System "HVAC -1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 25HBA424-30" includes credit for a 11.0 EER Condenser. EnergyPro 4.4 by EnergvSoft User Number: 6712 Job Number: Page:6 of 12 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit is documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfillration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, Water Heating and Plumbing System Measures ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑X ❑ ❑' o ❑ ❑ ❑ ❑ § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:7 of 12 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance • requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • 0 DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑x ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑X ❑ ❑ 11 a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa healers or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanent)y installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑x ❑ by an occupant sensor that complies with Section 119(d) that daes not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 12 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. & Mrs. John O'Keefe-Casita 8/3/2009 STEM NAME FLOOR AREA HVAC -1 486 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 393 8,834 325 568 9,594 0 916 733 0 0 0 0 0 0 0 0 0 916 1 733 10,666F 325 11,060 HVAC EQUIPMENT SELECTION Carrier 25HBA424-30 19,801 320 14,990 Total Adjusted System Output 19,801 320 14,990 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) � 26.0 of 69.1 of 69.1 of 86.7 of O49 Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 85'9 °F 800 cfm ROOMS 70.0 of 69.1 °F Return Air Ducts S DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 110.0 / 72.5 of 76.1 / 60.7 of 76.1 / 60.7 of 52.8 / 51.6 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 53.9 / 52.0 of 800 cfm 42.5% R.H. ROOMS 76.1/60.7 of 75.0 / 60.3 of Return Air Ducts E I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 12 4 4 F- L L ROOM LOAD SUMMARY PROJECT NAME Mr. & Mrs. John O'Keefe-Casita DATE 8/3/2009 STEM NAME HVAC -1 FLOOR AREA 486 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Casita 1 393 8,834 325 393 8,834 325 568 9,594 PAGE TOTAL 1 393 8,834 325 568 9,594 TOTAL 1 393 8,834 325 568 9,594 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 12 ROOM HEATING PEAK LOADS roject Title Date r. & Mrs. John O'Keefe-Casita 8/3/2009 Room Information Desi n Conditions Room Name Casita Time of Peak Jan 12 am Floor Area 486 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value OT of Btu/hr Tinted F 486.0 x x X X x X X X X X x X x x x X x x x X x X x x X x X X x X x X x X x X x X X 0.0280 X x x X X x X x X X x x X X x X x x x X x X x x X x x x x x x X X X x X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 599 233.0 0.0690 44 707 4.0 0.3900 44 69 4.0 0.3900 44 69 136.5 0.0690 44 414 3.5 0.7200 44 111 48.0 0.3900 44 824 208.0 0.0690 44 631 4.0 0,3900 44 69 4.0 0.3900 44 69 48.0 0.3900 44= 8 190.5 0.0690 44 578 3.5 0.7200 44 111 perimeter = 41.0 0.7300 44 1,317 perimeter = 57.0 0.7300 44 1 8.3 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: I 8,2221 Infiltration: 1 .001 X 1.064 X 486 X Height X 0.393 / 60] X 44 = 1 372 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,594 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 11 of 12 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title Date r. & Mrs. John O'Keefe-Casita 8/3/2009 Room Information Desi n Conditions Room Name: Casita Outdoor Dry Bulb Temperature: ill 0F Floor Area: 486 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 750F Outdoor Daily Range: 340F upaque surfaces R-38 Roof(R.38.2x12.24) IR-21Wall (W.21.2x6.16) I IR-21Wall (W.21.2x6.16) I Orientation Area X X X X X x x x x x x x U -Factor X X X X X x x x x x x x CLTD 1 N 486.0 0.0194 56.0 NE 233.0 0.0690 30.3 SE 136.5 0.0690 29.3 SW 208.0 0.0690 31.7 NW 190.5 0.0690 29.3 21.6 48.0 27.4 SW 0.0 21.6 4.0 31.1 SW 0.0 21.6 4.0 31.1 SW 0.0 21.6 48.0 31.1 NW 0.0 28.7 3.5 37.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration rage I otal Orientation Shaded Area x X x X X X x x X Ix GLF + + + + + + + + + + Unshaded Area x x X X X X x x x I x GLF NE 0.0 21.6 4.0 36.9 NE 0.0 21.6 4.0 36.9 SE 0.0x 28.7+ 3.5x 34.7 SE 0.0 21.6 48.0 27.4 SW 0.0 21.6 4.0 31.1 SW 0.0 21.6 4.0 31.1 SW 0.0 21.6 48.0 31.1 NW 0.0 28.7 3.5 37.0 I Page Total Btu/hr 528 488 276 454 385 2,1311 Btu/hr Internal Gain Btu/hr Occupants Eli Occupants x 230 Btuh/occ. = 460 E ui ment Dwelling Units x 1 1,6001 Btuh = 1,6001 Infiltration: 1.064 x 0.88 x 30.79 x 36 = 1043 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,834 Latent Gain Btu/hr Occu ants �2 Occupants x 200 BtuhloCC. = 400 Infiltration: 4 771 x 0.88 x 30.79 x 0.00058 = -75 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 325 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 12