BRES2015-024278-495 CALLE TAMPICO�
LA QUINTA, CALIFORNIA 92253
Application Number: BRES2
Property Address: 54447
APN: 77503
Application Description: MCCR
Property Zoning:
Application Valuation: $10,3,
Applicant:
BOB EDWARDS CONSTRUCTION 1
51-455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
C� 0 D 4 Qu&Z VOICE (760) 777-7125
FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/29/2015
�\ Owner:
W MCCRACKEN, MARY L
2126 CROSS ST
DE,N, (,E PtT fy tgfi)SU E 123 F LA CANADA, CA 91011
CITY OF lA QUJ%TA
LICENSED CONTRACTOR'S -DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 70001 of Divis' 3 f e)I Zinssd Professions Code,
and my Lic nse in full force and effect -
License Li ss: B C27 License No.: 684
-Date.Contractor.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that -
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_J I am exempt under Sec. . B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's
Contractor:
BOB EDWARDS CONSTRUCTION INCOR
51-455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
(760)777=8202
Llc. No.: 684857
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
_ I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier:_ Policy Number:
I certify that in the performance of the work for which this permit is.issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agre at, i I sho become subject to the
workers' mp sation provisions of Se io 37 0 of ALar ode, I shall forthwith
comply nth th se provisions.
Date. L Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application., the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances an at la relating to buildin
construction, nd hereby authorize representates ivof this ci o n r p the abov -
mention d pr perty for inspection purposes.
Date' 1 Signature (Applicant or Agent):
a.
-FINANCIAL INFORMATION
ACCOUNT QTY AMOUNT;
PAID,
PAID DATE
DESCRIPTION
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$62.36
$0.00
PAID BY r
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0-
$17.40
$0.00
• PAID BY
METHOD'
J RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forADDITION: $371.73 $0.00
DESCRIPTION
ACCOUNT "
QTY
AMOUNT,.
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
0.75
$52.50
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $52.50 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
DESCRIPTION.
ACCOUNT.
QTY
AMOUNT
PAID...
PAID, DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$0.00
PAID BY•
METHOD
RECEIPT #
CHECK # •
CLTD BY
DESCRIPTION.
ACCOUNT
QTY
AMOUNT.
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY.
` R
4' DESCRIPTION j ?ACCOUNT �T_~Y QTY ;AMOUNT PAID PAID"DATE:
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.83
$0.00
PAID
.,";-...METHOD, k .•
�.
RECEIPT # +
°CHECK #_'
CLTD BY'^
Total Paid for MECHANICAL: $16.92 $0.00
rr DESCRIPTION :�
s ACCOUNT ` `
X QTY
AMOUNT
:PAID
RAID DATE,
ROOF DRAIN
101-0000-42401
0
$12.09
$0.00
PAID BY
IVIETHOD'r
RECEIPT
DESCRIPTION
a ACCOUNT
QTY
:AMOUNT >
-PAID _„
PAID DATE:
ROOF DRAIN PC
101-0000-42600
0
$12.09
$0.00
.,PAID BY"
METHOD` a
RECEIPT #; y' 3
CHECK #.
CLTD BY,-;
Total Paid for PLUMBING FEES: $24.18 $0.00
DESCRIPTION
ACCOUNT. `•
QTY
AMOUNT
v: PAID _
RAID'UkTE
SMI - RESIDENTIAL"
101-0000-20308
0
$1.34
$0.00.
PAID:BY' '
METHOD
RECEIPT ,,.#
CHECK #.
s CLTD BY ;
Total Paid forSTRONG MOTION INSTRUMENTATION SMt $1.34 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID '
PAID DATE'
DOOR/WINDOW, NEW, EA ADDITION 1
101-0000-42400
0
$30.45.
$0.00
P AID BY;
Y `METHOD: a ,
RECEIPT
:CHECK,#
CMTP, BY :°,
DESCRIPTION ..
ACCOUNT T„
QTY ,
. `AMOUNT ='
PAIDPAID
DATE;
DOOR/WINDOW, NEW, FIRST 1
101-0000-42400
0
$60.91
$0.00
PAID BY
METHOD
RECEIPT #
,CHECK #
" CLTU BY
DESCRIPTIONS
- ACCOUNT
QTY
'.AMOUNT
PAID °
RAID DATE
DOOR/WINDOW, NEW, FIRST 1 PC
101-0000-42600
0
$59.46
$0.00
' PAID BY _,
METHOD',:',
RECEIPT# `
CHECK#'
uCLTD B.Y f
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $150.82 $0.00
Description: MCCRACKEN RESIDENCE PATIO ENCLOSURE 123 SF
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL Status: APPROVED
Applied: 6/22/2015 MFA
Approved: 7/29/2015 JJO
Parcel No: 775031029 Site Address: 54447 RIVIERA LA QUINTA,CA 92253
Subdivision: TR 24317-1
Block: Lot: 2
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled:
Valuation; $10,342.40
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0 No. Unites: 0
u ,COMPLETION
Details: ENCLOSE INTERIOR ATRUM, 128 SQ. FT. ADDITION PER 2013 CRC CODES
NOTE
37\-/
^ I Applied to Approved
1 _
Printed: Wednesday, July 29, 2015 2:40:24 PM 1 of 4 CRWrsrEMS
ADDITIONAL
CHRONOLOGY
. .. .v.i.. . w. :...: ':.
CHRONOLOGY.TYPE
+h:. t?'�i�hrr-...An.w4.YI�NK.`.�A �..
Y.k'�STAFF NAME.,, �"
".; ".... .,< : y ,:,:.% {,.. v/ Y'
ACTION DATE
-.. h.'r+;,•kR!•.MI..:.•. 2A.4) A s�:.
DATE '_
R �, ..� K
`
:_ ;
u ,COMPLETION
xt< 14,: ;NOTES . ,
NOTE
JIM JOHNSON
7/15/2015
7/21/2015
NOTE
KAY HENSEL
7/27/2015
7/27/2015
PLANS PULLED FROM JIM'S DESK AND PROCESSED
PLAN CHECK COMMENTS
FROM CONSULTANT
MARY FASANO
7/20/2015
7/21/2015
RETURNED FROM YOUNG STRUCTUAL APPROVED
RECEIVED
PLAN CHECK PICKED UP
PHILIP JUAREZ
7/23/2015
7/23/2015
PLANS PICKED UP BY GABRIEL RIOS
PLAN CHECK SENT TO
KAY HENSEL
7/6/2015
7/6/2015
STRUC TO YOUNG - DUE BACK 7/20/2015
OUTSIDE PC
PLAN CHECK SUBMITTAL
1ST PLAN CHECK SUBMITTAL RECEIVED 3 SETS OF PLANS,
RECEIVED
ED VASQUEZ
7/6/2015
7/6/2015
STRUCTURAL CALS, TITLE 24
CALLED GABERIL TO INFORM HIM PLANS ARE READY FOR
TELEPHONE CALL
JIM JOHNSON
7/21/2015
7/21/2015
CORRECTIONS .
Printed: Wednesday, July 29, 2015 2:40:24 PM 1 of 4 CRWrsrEMS
pugugm
x. R Rgffi,,�
1�,n� 'emAT VA.QXVJJx1'&V',V1 WIRI
. . . . . . . . . .
MINNOW I i N1,
i�
Nk
APPLICANT BOB EDWARDCINSTRPCIION LA QU I NTA (
I-NCOR DRIVE
,«....,,
g,
I
BE �yell " , 0 MR - R
W -114M, 111-1-0.1,10, WAN 0-011- a
I A-CCOUNT 4 -15
10W "IMM"60 7,,( 11 "M
�150= M
A? Raff
I WE hl� W_ TO,
&� pi. g pg
.4.
'4RECEV
T
MEX
NMI
ADDITIO N
-1 1 , , EA.' '
- 101-0000-42400 0
$62.36
ADDITIONAL:500 SF
ADDITION, EA,
1 11 . 1
'101-0000-42600' 0
$17.40
.$0.00ADDITIONAL
500 SF PC
ADDITION, FIRS T'100 SF-
101-0000-42400 q
$120.93
$0.00
ADDITION, FIRST -100 SF
101-0060-42600,
$171.14
$0.00
PC
Total Paid forADDITION: -$371.73 $0.00
-HOURLY PLAN CHECK"-]
101-0000-42600
5
7
$52 , M-
70
0
YE
T PER HOUR. .00
Total Paid for BLDG CITY STAFF $52.90
BSAS 561473 FEE
101-0000-20306 7[
70 •$1.00
:7 $0.00,
.,,,Total Paid forBUILDING STANDARDS ADMINISTR . ATION' $
U . $0 00—
lo.x_
RESIDENTIAL, FIRST
01-0000-41403
0
$145M60
0.1
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
• BY
RESIDENTIAL; FIRST
101-0000-42600
0
$47.86
$0.00
1,000SF, PC
Total Paid forELECTRICAL - NEW CONSTRUCTION: _ $192.89 $0.00
APPLIANCE
101-0000-42402
0
$12.09
$0.00
REPAIR/ALTERATION
APPLIANCE
101-0000-42600
0
$4.83
$0.00
REPAIR/ALTERATION PC
Total Paid forMECHANICAL: $16.92 $0.00
ROOF DRAIN
101-0000-42401
0 1
$12.09
$0.00
ROOF DRAIN PC
101-0000-42600
0
$12.09
$0.00
Total Paid for PLUMBING FEES: $24.18 $0.00
SMI - RESIDENTIAL
101-0000-20308
1 0
$1.34
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SMt $1.34 $0.00
DOOR/WINDOW, NEW,
101-0000-42400
0
$30.45
$0.00
EA ADDITION 1
DOOR/WINDOW, NEW,
101-0000-42400
0
$60.91
$0.00
FIRST 1
DOOR/WINDOW, NEW,
101-0000-42600
0
$59.46
$0.00
FIRST 1 PC
Total Paid for WINDOW/SLIDING GLASS '
$150.82 $0.00
DOOR/FENESTRATION:
TOTALS:• ••
INSPECTIONS
SEQID' "'"' INSPECTION TYPE'INSPECTOR
SCHEDULED: COMPLETED '" RESULT: ' REMARKS:: NOTES
DATE' DATE .
FINAL*" BLD
PARENT PROJECTS
Printed: Wednesday, July 29, 2015 2:40:24 PM 3 of 4 CRWrsTEMS
C .
�, �;r:- � .-i ;t A � g Ss., � "'�.w,r� :��� ate • ' + a : ��� �t"��i�, . e s,,,�r.�.�...�ri �.
�... r^ .. _..tt' ..... .,._. ,� .. • ;yq. .� ,.. „� .h,..r.. m. ..._�� �r»: =�- Y;�. kp ... ,� �,.•'4,.,r.«srirMvu•tna •+.R.�wr+F '.�.-
l�.t .,r 3 b`�� d t, �; r. N c. � �� _,� r ,r. •'-ry°y'.� Y sem"+ � `d,�Y � F#. �L . v.. � : a. t
_d
�r
r •
5+y, ;,...r -M p -E ,.{ ."•""Y'sr-•.X1 :4,.'"` *!'. .`:k.- . ..yam„-- :t .M: -s• ".: J. .L�ii'aXl: :fi"'^
i`'?�xz..s,•s.�., rRETURNEO�'. : STATUS.. ... _kREMARK "N �•�'-k+ ai.~'�y».rii,r}rv.
REVIEWffTYPE,: ` . REVIEWER. ';SENT DATE.';§r'�DUt DATE t�:'fi�tt� ..,�a •. 1r ,,.•- ' ? }}' Ss x ?�>. �* y NOTES .: P :
°sy'4
-{-. _.2 .aa.e•,.,; .lac' a� !'sy,. 'v xt�:f*+''�^ .a,.- .syit;< Pzl,. ;«i+.`st1 $:ex ,r .,C. i has
DATE" '� �..t.� ate: S: .a'."�'{€.'-�,%•'•2«.aiF
.�,�+"a_kcc.,,s, Ky),
r,f
'3 i a ;< C .xl�!ii. .`-kd wei Y <��M. " T1G2 +A :.J�: ttd:s,4-&sbitiaca..Yl di�1L+4':..+eMs. :S'leY ik.'\St%"JMi
+ + (a� t t
•+•ro�''r �7 r i �Ke
y.
2 WK
STRUCTURAL - 2 WK YOUNG 7/6/2015
7/20/2015. 7/20/2015 READY FOR APPROVAL
ENGINEERING
C .
�, �;r:- � .-i ;t A � g Ss., � "'�.w,r� :��� ate • ' + a : ��� �t"��i�, . e s,,,�r.�.�...�ri �.
�... r^ .. _..tt' ..... .,._. ,� .. • ;yq. .� ,.. „� .h,..r.. m. ..._�� �r»: =�- Y;�. kp ... ,� �,.•'4,.,r.«srirMvu•tna •+.R.�wr+F '.�.-
l�.t .,r 3 b`�� d t, �; r. N c. � �� _,� r ,r. •'-ry°y'.� Y sem"+ � `d,�Y � F#. �L . v.. � : a. t
_d
�r
r •
5+y, ;,...r -M p -E ,.{ ."•""Y'sr-•.X1 :4,.'"` *!'. .`:k.- . ..yam„-- :t .M: -s• ".: J. .L�ii'aXl: :fi"'^
i`'?�xz..s,•s.�., rRETURNEO�'. : STATUS.. ... _kREMARK "N �•�'-k+ ai.~'�y».rii,r}rv.
REVIEWffTYPE,: ` . REVIEWER. ';SENT DATE.';§r'�DUt DATE t�:'fi�tt� ..,�a •. 1r ,,.•- ' ? }}' Ss x ?�>. �* y NOTES .: P :
°sy'4
-{-. _.2 .aa.e•,.,; .lac' a� !'sy,. 'v xt�:f*+''�^ .a,.- .syit;< Pzl,. ;«i+.`st1 $:ex ,r .,C. i has
DATE" '� �..t.� ate: S: .a'."�'{€.'-�,%•'•2«.aiF
.�,�+"a_kcc.,,s, Ky),
r,f
'3 i a ;< C .xl�!ii. .`-kd wei Y <��M. " T1G2 +A :.J�: ttd:s,4-&sbitiaca..Yl di�1L+4':..+eMs. :S'leY ik.'\St%"JMi
NON-STRUCTURAL - JIM JOHNSON 7/6/2015
7/20/2015 7/15/2015 REVISIONS REQUIRED
2 WK
STRUCTURAL - 2 WK YOUNG 7/6/2015
7/20/2015. 7/20/2015 READY FOR APPROVAL
ENGINEERING
NON-STRUCTURAL - JIM JOHNSON 7/24/2015
8/7/2015 7/29/2015 REVISIONS REQUIRED
A TOLD ME TO PUT ON HIS DESK.
2 WK
Printed: Wednesday, July 29, 2015 2:40:24 PM 4 of 4 CESYSTEMS
Bln. #
Ot Of I.d uinta
Building a Safety Division
Y P.O. Box 1504,78-495 Calle Tampico ,
La.Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
�0 Sb
Project Address: 554 q 4 1 vi wa-C�Cj!
Owner's Name:. } M
A. P. Number.
Address: 2 ZlP (,BOSS A
Legal Description:
Contractor. 13019 65 waA-aS anS+MCI +QM
2
City, ST, Zip: �� l.(Jt-f IQUISk. � 101 I ' ( 3A
Telephone:
Address: SS i
Project Description:
City, ST, Zip: La �
Telephone: -7 (DO -I ?202
State Lic. # : (Q F14 City Lie'. #00032,12
Arch., Engr., Designer. ReS>3. (,tom C
S+yu c
City., ST, Zip: V
Telephone: r' ° '
State Lic. #: C. (0--1 CP 1 �w ;'
Name of Contact Person: '60� j F—rI WcLrCLS
Construction Type: �LiY) dLIA JL Occupancy:
Project type (circle one): New Add'w:,-1Alter Repair Demo
Sq, FL: '
# Stories: # Units:
Telephone # of Contact Person: I U 0 •r77? • 72DZ
Estimated Value of Project bee
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKNG
PERMIT FEES
Plan Sets
Pian Check submitted
Item Amount
S"cturai CaIcs.
a
Reviewed, ready for corrections
Plan Check Deposit. .
'ice Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calci.
Plana picked up
Contraction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2id Review, ready for correctionsrissue
Electrical
Subeontactor List
Called Contact Person
Plumb[ag
Grant Deed
Plans picked up
S.M L
H.O.A. Approval
Plans resubmitted
Grading
w HOUSE:-
'^` Review; ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road ¢ BERMUDA DUNES t"
O
Date 7/29/15 La Quints, CA 92253 C40 RANCHMIRAGE t_-1INDIAN WELLS r
PALM DESERT
No. 31880 (760) 771-8515 `�J' LA
INDIOTA
�Q � y'J
Owner McCracken APN # 775-031-029
Address 54447 Rivera St Jurisdiction La Quinta
City La Quinta Zip 92253 Permit #
Tract # No. of Units
Type Residential Addition
Lot # No. Street S.F. Lot # No. Street - S.F.
Unit 1 - 54447 Riviera St
Unit 2
Unit 3
Unit 4
Unit 5
Comments Exempt
128 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named. owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 128 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project.may now be issued.
Fees Paid By Exempt/ Robert Edwards Check No.
Bank Name/Recipient of Certificate Telephone 760-777-8202
Funding Exempt
BY Dr. Gary Rutherford
Superintendent
Fee collected /exempted by Kelly Jones Payment Recd,r .t�0.0 -
Over/Un�er�' �a� Q^
Signature c !t
NOTICE: Pursuant toGovem t Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
BUILDING ENERGY ANALYSIS REPORT
PROJECT:.
McCracken Residence
54447 Riviera
La Quinta, CA
Project Designer:
5
p6
w� QVC oe ,01
fReport Prepared by: coMM
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
CIS' OF
` epicprN� & QUINZA
PP
R coN RUC7-1
® .
Job Numb DATE
Date:
7/1/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California. Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPro 6.4 by EnergySoft User Number. 2655 ID:
TABLE OF CONTENTS `
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
-j
f
CITY OF LA QUINTA
BUILDING & SPT.
APPROVED
FOR CONSTRUCTION
- BY
EnergyPro 6.4 by EnergySoft Job Number: ID: User Number. 2655
f
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Fam Detached Calculation Date/Time: 11:08, Wed, Jul 01, 2015 Page 1 of 9
Calculation Description: Title 24 Analysis Input File Name: McCracken 2.xml
GENERAL INFORMATION
01
Project Name Single Fam Detached
02
Calculation Description Title 24 Analysis
03
Project Location 54447 Riviera
-
04
City La Quinta
05
Standards Version Compliance 2014
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-3b1 (694)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.4
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 225
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 2974
15
Number of Zones 2
16
Slab Area (FT2) 2974
17
Number of Stories 1
18
Addition Cond. Floor Area 128
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) 128
21
Glazing Percentage (%) 13.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
This compliance analysis is valid only for permit applications through December 31, 2014
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use Standard
(kTDV/ft2q,) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
-t Space HeaTag' 10.16
10.14
0.02
0.2%
Sp3�' e0 o ' g 240.33
244.66
-4.33
-1.8%
IA en - an ® 0.00
0.00
0.00
0.0%
watt H t 8.97
4.58
4.39
48.9%
Phot I ----
0.00
0.00
----
tplia r T al I . 259.46
259.38
0.08
0.0%
4J��z
Registration N er:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFSR-01152015-694
HERS Provider:
Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Fam Detached Calculation Date/Time: 11:08, Wed, Jul 01, 2015 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: McCracken 2.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cathedral Ceiling
• Window overhangs and/or fins
- - -- ------------
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
- - None --
Cooling System Verifications:
- - None --
HVAC Distribution System Verifications:
- -None --
Domestic Hot Water System Verifications:
• - None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy UseEnergy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)- 301.39 301.3E 0.08 0.0%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION coo
01
01 tT1
-n
03
04
05
06
07
T a
� _
Number of Dwelling
Avg. Ceiling
Height
Water Heating System 1
Number of Ventilation
Number of Water
Project Name
Con tioh2d�lo r a (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Single Fam Detached4-n
Living Zonal
1
6
2
0
1
ZONE INFORMATION 03 - D
01
C m
03
04
05
06
07
Zone Name
T a
HVAC System Name
Zone Floor Area
(ftz)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Livingn
itio
Living Zone1
2846
10
DHW Sys 1
Addition
Conditione
Living Zonal
128
10
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 11:08, Wed, Jul 01, 2015
Calculation Description: Title 24 Analysis Input File Name: McCracken 2.xml
CF1R-PRF-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04 05
06 07
08 09
10
Name
Zone
Construction
Azimuth Orientation
Window and Door
Gross Area (ft2) Area (ft)
Tilt
(deg) Status
Verified
Existing
Condition
Front Wall
Existing Living
Default Wall 1978 to 1991
225 Front
1500
90 Existing
No
Left Wall
Existing Living
Default Wall 1978 to 1991
315 Left
1300
90 Existing
No
Rear Wall
Existing Living
Default Wall 1978 to 1991
45 Back
1500 151.952
90 Existing
No
Right Wall
Existing Living
Default Wall 1978 to 1991
135 Right
1300 194.842
90 Existing
No
Roof 3
Existing Living
Default Roof 1978 to Pres
n
2827
Existing
No
Front Wall 2
Addition
R-19 Wall1
225 Front
10
90 New
N/A
Left Wall 2
Addition
R-19 Wall1
315 Left
10
90 New
N/A
Rear Wall 2
Addition
R-19 Walli
45 Back
10
90 New
N/A
Right Wall 2
Addition
R-19 Walli
0 135
10
90 New
N/A
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
07
06
07
08
09
10
11
12
13
Status
Verified
Existing
Condition
Attic Existing L vi g 90 Attic Roof Cons Existing
0
0.1
0.85
No
No
Existing
Roof
Roof
Framin
Verified
Orientatio
Area
Skylight
Roof Rise
Roof
Roof
Reflectan
Emmittan
g
Statu
Existing
Name
Zone
Type
n
(ft)
Area (ft2)
(x in 12)
Pitch
Tilt(deg)
ce
ce
Factor:
s
Condifion
Roof
Existing Living
Default Roof 1978
Front
16.1
16
0
0
0
0.1
0.85
0.1
Exigstin
No
to Pres1
Roof 2
Addition
R-30 Roof Attic
I Front
128
40.5
0
0
0
0.1
0.85
1 0.1
New
N/A
ATTIC
01 02
03
04
05
06
07
08
09
O
Name O Construction
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool Roof
Status
Verified
Existing
Condition
Attic Existing L vi g 90 Attic Roof Cons Existing
0
0.1
0.85
No
No
Existing
No
r55®0
R'o Zi
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 11:08, Wed, Jul 01, 2015
Calculation Description: Title 24 Analysis
Input File Name: McCracken 2.xml
CF1 R -PRF -01
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft2)
11.11 -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Rear Wall (Back -45)
6.0
6.8
0.98
40.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 2
Rear Wall (Back -45)
8.0
2.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 3
Rear Wall (Back -45)
4.0
4.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 4
Rear Wall (Back -45)
12.0
6.8
0.98
80.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 5
Right Wall (Right -135)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 6
Right Wall (Right -135)
4.0
2.0
1
8.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 7
Right Wall (Right -135)
8.0
2.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 8
Right Wall (Right -135)
4.0
4.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 9
Right Wall (Right -135)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 10
Right Wall (Right -135)
2.0
8.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 11
Right Wall (Right -135)
2.0
8.0
1
16.0
1 0.71
0.73
Insect Screen (default)
Existing
No
Window 12
Right Wall (Right -135)
2.0
8.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Skylight
Roof (Front -225)
1
16.0
0.35
0.22
Altered
N/A
Skylight 2
Roof 2 (Front -225)
1
40.5
0.35
0.22
New
N/A
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 11:08, Wed, Jul 01, 2015
Calculation Description: Title 24 Analysis Input File Name: McCracken 2.xml
CF1 R -PRF -01
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
1 0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 9
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 10
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 11
2
0.1
2
2
0
0
1 0
0
0
0
0 0
0
Window 12
2
0.1
2
2
0
0
0
0
0
0
0 0
0
D
CA 0
M '>1 > C
00
0-020
o�-n
-c c®m0
ni
M: C
Z
Registration Number: z ®�
CA Building Energy Efficien tandards - 2013 Resident
Registration Date/Time:
Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Datelrime: 11:08, Wed, Jul 01, 2015
Input File Name: McCracken 2.xml
CF1 R -PRF -01
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
-
rn a !
rs
Total Cavity
Winter Design
Construction Name
-Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Existing
e `- Zone
Area ftZ
ft
- Cavity/Frame: no insul. /2x4 Top Chrd
Fraction
Heated
Status
2x4 Top Chord of Roof Truss Cal 24
Cov r d Slab C) - Existing Living
2846
- Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons Existing
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
- Roofing: Light Roof (Asphalt Shingle)
2
None
0.8
No
I New
No
- Inside Finish: Gypsum Board
- Cavity/Frame: R-11 /2x4
- Exterior Finish: Wood
Default Wall 1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R11
0.103
Siding/sheathing/decking
- Inside Finish: Gypsum Board
Ceilings (below
- Cavity/Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 ® 16 in. O.C.
R 19
0.049
- Over Floor Joists: R-9.9 insul.
- Inside Finish: Gypsum Board
- Cavity/Frame: R -19/2x4
- Roof Deck: Wood Siding/sheathing/decking
Default Roof 1978 to Pres1
Cathedral Ceilings
Wood Framed Ceiling
2x4 ® 16 in. O.C.
R 19
0.061
- Roofing: Light Roof (Asphalt Shingle)
- Inside Finish: Gypsum Board
- Cavity/Frame: R -19/2x6
- Exterior Finish: Wood
R-19 Walll
Exterior Walls
Wood Framed Wall
2x6 Cal 16 in. O.C.
R1 9
0.069
Siding/sheathing/decking
- Inside Finish: Gypsum Board
- Cavity/ Frame: R -19/2x8
- Roof Deck: Wood Siding/sheathing/decking
- Above Deck Insulation: R10 Sheathing
R-30 Roof Attic
Cathedral Ceilings
Wood Framed Ceiling
2x8 C4+ 16 in. O.C.
R 19
0.034
- Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01 _. ,. 02
03
04
05
06
07
08
09
rn a !
rs
Verified
_
�a 0.
Perimeter
Carpeted
Existing
e `- Zone
Area ftZ
ft
Edge Insul. R -value
Fraction
Heated
Status
Condition
Cov r d Slab C) - Existing Living
2846
1500
None
0.8
No
Existing
No
I bAddition
128
2
None
0.8
No
I New
No
BUILDING ENVEL P¢- HER
R F*
01
iTl 02 03 04
Quality Mulation t6faiO4
((K Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Re
II42r
Not Required Not Required ---
U ~
Registration Num el: D Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 esidential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 11:08, Wed, Jul 01, 2015
Calculation Description: Title 24 Analysis Input File Name: McCracken 2.xml
CF1 R -PRF -01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
- -
System Type
Distribution Type
-
Water. Heater
Number of
Heaters
Solar
_ Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Altered
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0.1
0.99 EF
199000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
S =
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Ducted
Name Ducted
System
System
Served
Status
Condition
Living Zone1
Other Heating and
JNe
CO
Yes
Cooling
Yes
Air Distribution
HVAC Fan
2974
Existing
No
Cooling System, a
C9t
1
Component 1
System 1
1
HVAC - HEATING SYSTEK
S =
0102
03
Name Z X wo
Type Efficiency
Heat
ng!qomPor#(0 D >
CntrlFurnace - Fuel -fired central furnace 78 AFUE
�
M:�C
z ® m -z-I
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:08, Wed, Jul 01, 2015
Input File Name: McCracken 2.xml
CF1 R -PRF -01
Page 8 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
T
05
Efficiency
07
Multi -speed
09
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10.42
12
No
No
N/A
Duct Leakage
system
Location
Location
Bypass Duct
Status
Condition
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
8.0
Attic
Attic
None
Existing
No
N/A
System 1
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number:
CA Building Energy Efficiency
MC
0> 0
0 z
z���
W®��
mom
0Mc
°z® m z
Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-07-0111:10:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation DatelTime: 11:08, Wed, Jul 01, 2015
Calculation Description: Title 24 Analysis Input File Name: McCracken 2.xml
CFI R -PRF -01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan D. Hacker F
D�
Company:
Signature Date:
Insu-form, Inc.
7/1/2015
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/State ip: Phone:
Falm Desert, Ca 92211
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the informatio vided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit appli tion.
Responsible Designer Name:
Responsible Designer Signature:
Gabriel Rios
Company:
Date Signed:
Rios Designs
07/01/2015
Address. 49-901 Cinnabar Lane
License:
N/A
City/State/Zip: ------
Phone:
Coachella, CA 92236
(760) 485-7431
0>o
0�G)0
�-WC°r
®>
-n
m
�<.0
�M_:
Z®Mz
HU--q
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-07-0111:10:02
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
McCracken Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/1/2015
Project Address
54447 Riviera La Quinta
California Energy Climate Zone
CA Climate Zone 15
I Total Cond. Floor Area
2,974
Addition
128
# of Units
1
INSULATION
Construction Type
Area
Cavit(ft) Special Features Status
Slab Unheated Slab-on-Grade
- no insulation 2,846 Perim = 1500' Existing
Wall Wood Framed
R11 5,253 Existing
Roof Wood Framed Attic
R 19 Z827 Existing
Demising Wood Framed
R19 1 Existing
Wall Wood Framed
R 19 40 New
Roof Wood Framed Rafter
R 19 88 Rigid=R-10.5 New
Slab Unheated Slab-on-Grade
- no insulation 128 Perim = 2' New
FENESTRATION
Orientation Area(ft)
I Total Area: 403 Glazing Percentage: 13.6 % New/Altered Average U-Factor: a35
U-Fac SHGC Overhang Sidefins Exterior Shades Status
Rear (NE) 152.0
0.710 0.73 2.0 none Bug Screen Existing
Right (SE) 194.8
0.710 0.73 2.0 none Bug Screen Existing
Skylight 16.0
0.350 a22 none none None Altered
Skylight 40.5
x350 0.22 none none None New
HVAC SYSTEMS
-Qty. Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace
78% AFUE Split Air Conditioner 12.0 SEER Setback Existing
HVAC DISTRIBUTION CITY OF LA QU
Location Heating Cooling Duct Location I II
TA
g.
Living Zone Ducted
Ducted Attic
.
WATER HEATING
Qt . Type
.T
Gallons Min. Eff Distribution BY--stetas
1 Small Instantaneous Gas
0 0.99 All Pipes Ins Altered
Ener Pro 6.4 by Ener Soft User Number.- 2655 RunCode: 2015-07-01T11:12:17 ID: Pae 12 of 17
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may aDDly. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§I 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(1) when the
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-] 9 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum'U-factor.
§150.0(g)]:
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
§ 150.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class H vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)l C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, house ces appl -
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consu e ess tha 1 Iae�i 00
ands a heaters. ' rITY
§150.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMA NA! * �u n �(i ci
in 150.0(h)2. L
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearanA 1 t o u let of a y
dryer vent. rC)NUCTION
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of§ 1 .2(c).
§ 150.0(j)1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards she extrna
elly wrapped
with insulation having an installed thermal resistance of R-12 or greater. E
§ 150.00)] B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar wate - ms, ave R-12 extemal
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ ] 50.06)2B:
All domestic hot water pipes that are buried below grade must be installed in a waterproof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.06)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure> 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.06)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)]:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '% inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
§ 150.0(m)12:
Mechanical systems that supply air to an occupiable space through ductwork exceedi n ou rrrt
conditioning component, except evaporative coolers, shall be provided with air fijt rewjc *,efth i
§150.0(m)12. Y
Space conditioning systems that utilize forced air ducts to supply cooling to an o` eprppLl to e VRKe '
placement of a static pressure probe (HSPP), or a permanently installed static presStrre Mum. Th
§150.0(m)13:
space conditioning system must also demonstrate airflow >_: 350 CFM per ton of nomi j g o etum
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field ver foMine fres '
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mod
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwell..' of on£ -
350 CFM i tn'
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as con'f gnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ ] 50.0(0)] A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ I I0.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)]A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ 150.0(k)]B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)]F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §1 50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ I50.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook a
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 w� pyve(p�
cabinet. � � i v T•
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and alla a i t 1Li� 1 t}�om
shall be high efficac or controlled b vacancysensors. �J
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility roor�ms shall b �
C�cO
controlled b vacancysensors. i
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, lauddry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors. PX
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact Q9M U� o on
nationally recognized testing/rating laboratory; have a label that certifies that the lu •naire i it eakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a ga et or caulk between the luminaire housing
§I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, 130.0, § 130.2, §130.4, § 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §1 50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9 § 130.0 § 130.2 § 130.4 § 140.7 and 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§I50.0(k)] 1:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 130.0 § 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l :
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(6) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excludinga
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented be ees d 0omewoleh
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural feat � 9 o f n u t sshalLbe
located in the solar zone. Dr -ft
§ ] 10.10(b)3B:
Any obstruction, located on the roof or any other part of the building that projects _ 1 0 least e
the distance, measured in the horizontal plane, of the height difference between the big t e
horizontal projection of the nearest point of the solar zone, measured in the vertical latfe " T{��U��U������VVVVVV
§ 110.10(6)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead a ive load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathwaYgr Wu iag e€cvndti
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for sirigl9 f nc
interconnection will be the main service panel); a pathway for routing of plumbing from o ar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110. ] 0(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e) 1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ l 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
McCracken Residence
Date
7/1/2015
System Name
Living Zone
Floor Area
2,974
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
4,827
0
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 70,000
59,094
2,939 3,567
97,801
Total Output Btuh 70,000
0
Output Btuh/s ft 23.5
3,411
4,807
Cooling System
0
0
Output per System 58,000
0
0 0
0
Total Output Btuh 58,000
0
3,411
65,917 2,939
0
Total Output ons 4.8
4,807
Total Output Btuh/s ft 19.5
Total Output s ftfTon 615.3
1 107,414
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow cfm
2,210
Existing
33,877 21,298
70,000
Airflow cfm/s ft
0.74
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
33,877 21,298 70,000
Aug 3 PM Jan 1 AM
Airflow cfm/Ton 457.2
Outside Air°io 0.0%
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26'F 68'F
Outside Air
0 cfm Supply Fan
2;210 cfm
68'F
68 OF 98 OF
Heating CoilAL
1 QUIN
r /�'� v� A CITY OF
_
BUILDING & i
APPR
; FOR CONSTRUCTIO"o F
^PTEA_ BY
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peaky-
eak -112
112/ 78'F 79169
Outside Air
0 cfm
79169'F
OF 79169 °F .65 / 64'F
Supply Fan Cooling Coil
2,210 cfm
- 7
JII�1
66 / 65 OF
- -
62.7 % ROOM
78169 OF