9810-120 (AR)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
59w)O 13 3131ioo
D" ate �i Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
TATI. P. M.) 1297971-n107
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of,Section 3700,of the Labor
Code, I shall forthwith comply with those provisions! .'
Date: l ` t t L Applicant `. ,`_'^ .• <
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person .at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agent) = t ''ti L ':'- L `t=� Date '
PERMIT # CONTROL #
BUILDING PERMIT 98110.1x11► �
DATE VALUATION 57,579,()11} LOT TRACT;' 8477
JOB SITE
ADDRESS 54-949 RIVIERA
APN 769.403.023
OWNER
CONTRACTOR / DESIGNER / ENGINEER
CHRIS IY)NIXY
CAI,""I'CH 11011.01:EZE
34-91,13 RIVI13RA
32-711 AVENIDA VELASCO
LA QU1NTA CA 9'2253
LA Qi11WA. CA 92153
(7601564-1309 C,111,ff '102,
USE OF PERMIT
Gi.NFII M, liL4ILLANG
OFF [CE: t1i3lril'LIGN ADD M-DUOR WAILS TO PARN i0N GARAGE SPACE,".
AL0 LX0 SIC TO ;..)UR'i Y AUD
CUSTOM S RoONi f cs^jovu 130+.00 SI
MAT El'D COST f.?�� C I N II'VI CY., N
;`,.�"':.Lt1
g�y-� Y p..E+.S''IT
;iqq,i �^ FEE
PRIIRMI E C EE dl3�R�i�AR yT
PLAIN (-'I1ECK YWr", 101-W!-430-3 18 $04.35
r!DNTfR1If7rf0NF'F;f; 1(}t -IM -418.000 S99.IN►
INIEC dANIC A1. FEE 101-0010-12t-01011 S2I.50
C1Xt:I`IGCAt. Fhas 101-00CL420-000 Si9.�5
Y' RON. 0 MOTPuN F&,' - RESID 101AW-241-M
ORADING H1!9;t1I-M)423-MO?r11.+Ni
s�
1;
,r A 'fr
iS1C'�h1CP
��
t6IF�
J91. LFSS f11111-PAID y
J/om
NOV 19 1998
TOTAL 11,`RM1'I• F ERS DUE NOW
5225,16
,ITY OF LA QUI%' T'
e.
ECEIPT D�T� / /
B
DATE FINALED
INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE I
IINSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
�2 �7 _ Q
Compressor
Insulation
Fire lace P.L.
P
/ [ T
Vents
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
iil !!t
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas'Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
Notice:
Document Cannot Be Duplicated
Desert Sands Unified School District
47-950 Dune Palms Road
La Quinta, CA 92253
760-771-8515
CERTIFICATE OF COMPLIANCE
Date 10/22/98 APN # 769-403-023
No. 17910 Jurisdiction La Quinta
Owner NameChris Donley Permit #
No. 54-949 Street Riviera Log #
City La Quinta zip 92253 Study Area
Tract # Lot # Square Footage 130
Type of Development Single Family Residence
Comments
No. of Units 1
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes.
It has been determined the above-named owner is exempt from paying school fees at this time due to the following
reason: AI
�.
EXEMPT
This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of
0.00 X 130 or $ 0.00the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued
Fees Paid By Exempt Telephone 760 564-1309
Name on the check
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by
Signature
Olivia Aguirre
.Exempt
Check No. N/A
$0.00
F
TICE: Pursuant o Assembly Bill 39 1 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified
ove will begin to from the dale on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
llect them on the District('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy = Accounting
. _ r . � _:.
i
. r ` . .. �.
CONSTRUCTION ESTIMATE
NO• ELECTRICAL FEES
NO. ?LUMBING FEES
IST F! SO FT ,? E
2ND FL. SO. FT. ,$
POR SO
GAR S0 FT ,q,
SAR P j0. FT
WALL SO FT Z
50 CT. u
ESTIMATED CONSTRUCTION VALUATION S
UNITS
MOBILEHOME SVC.
POWER OUTLET
YARD SPKLR SYSTEM
BAP SINK I
ROOF DRAINS
DRAINAGE PIPING
DRINKING FOUNTAIN
URINAL
WATER PIPING
. NOTE: Not to tte useo as ,(ooeny :ax gw.att°n
BONDING
FLOOR DRAIN 1
MECHANICAL FEES
FORMS
WATER SOFTENER
VENT SYSTEM FAN EVARCOOL HOOD
SIGN
WASH ER(AUTO)IDISH)
APPLIANCE DRYER
GAS (ROUGH)
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
OTHER APPJEOW P.
LAUNDRY TRAY
AIR HANDLING UNIT CFM
TEMP. POLE
KITCHEN SINK '
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE. TEM/PERM
LAVATORY.
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. tg. c
BATH TUB
SO. FT. 0 c
WATER HEATER
MAX. HEATER OUTPUT, 'd.T.U.
SU. FT. RESID r,* 1!4 c
SEWAGE DISPOSAL
SO.FT.GAR (g 4c
HOUSE SEWER
REMARKS:
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE •
' IAECH.FEE LPL.CK.FIEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL • HEATING A AlR GOND, SOLAR
SETBACK
GROUND PLUMBING .
UNDERGROUND
A.C. UNIT
COLL AREA
SLAB GRADE
ROUGH PLUMB,
BONDING
HEATING (ROUGH)
STORAGETANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL►
OTHER APPJEOW P.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd,
= PIUa
of
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
REMARKS:
VENTILATION r
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIOWSOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INBPEGTVKS SIaMATYNE9RN1T1A16
GARDEN WALL FINAL
A
TITLE 24 REPORT FOR:
Donely Residence, (Office Addition)
54-949 Riviera
La cru i nta , CA 92253
PROJECT DESIGNER.
Shenasi Design
P.O. Box 2771
Palm Desert, CA 92261
(.760 j 779-5996
REPORT PREPARED BY
Tim -Scott.
BREEZE ATR CONDITIONING
75-145 ST CHARLES PLACE
PALM DESERT, CA 92260
( 619 ) 346-0855
Job Number:
Date. 9/12/1998
The COMPLY 24.computer program has been used to perform the calculations
summarized in this compliance report. This program has approval and is
autnorized by the California Energy. Commission for use' with both the
Residential and Nonresidential Building Energy Efficiency Standards.
.This program 'developed' by,Gabel Dodd/Energysoft, llc (415) 883-5900
Table Of Contents for Title 24 Report
Cover Page..... ........... ....................... 1.
Table of Contents ... ........................... ................... 2
Form CF--1H Certificate of Compliance .............................. 3
Form MF-IR Mandatory Measures Checklist .. .. ..... ........ 5
Form C-2K Computer Method Summary.... 7
Form ENV-3 Construction'Assemblies................................. 10
HVAC System Loads Summary ................. ................... 15
Zone Heating Loads Summary.................................... 16
Zone Cooling Loads Summary ......... .................. 17
Form CF-6K 'Installation ,Certificate .. ... .... .. 18
CERTIFICATE OF COMPLIANCE - Residential (part 1 of 2) CF -1R page 3 of 18
---------------------------------------------------------------------------
Project Name Donely Residence (.Office Addition) ;Date: 9/12/1998
Address: 54-949 Riviera
L'a Ouinta, CA 92253 'Building Permit No
Designer: Shenasi Design ;Checked by / Date
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
GENERAL INFORMATION
Compliance Method COMPLY 24 version 5.10
Climate Zone: 15
Conditioned Floor Area:' 130 sgft•
,Building Type: Addition
Occupancy -type: Single Fam Det
Building Front orientation: 90.deg (E)
f
Number.oDwelling Units: 1
Floor Construction Type:, Slab on Grade
BUILDING,SHELL INSULATION
Component U -Value Location/Comments
R-21 Wali (W .21.2x6 .16) 0.,059 Office -Addition
Solid Wood Door 0.387 office Addition
R-38 Roof(R.38.2x14.16) 0.029 office Addition
Slab Perimeter w/R-0.0 0.900 office Addition
Slab Perimeter w/R-0.0 0.720 Office Addition
FENESTRATION Shading Devices Frame
Orient. Area U-val Type Interior Exterior OH SF Type
Back (W) 33.3 0.55 Double Std Drape none N N Wood
THERMAL MASS Area Thick
Type Covering (sf), (in) Location/Description
Concrete, Heavyweight Exposed, 30 3.50 Slab on Grade
Concrete, Heavyweight Covered 100. 3.50 Slab on Grade
CERTIFICATE OF COMPLIANCE - Residential (part L of 2) CF -1R' page 4 of 18
Project Name: Donely Residence (Office Addition) ;Date: 9/12/1998
• i •
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
HVAC SYSTEMS Minimum . Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
=------------------------------ ------ ---- ------ -----------------------
Furnace 0.800 AFUE Ducts in Attic 4.2 SetBck Office Add Lone
SpltAirCondlo.500 SEER Ducts in Attic 4.2 SetBck
Water No.Tank Ext.
WATER HEATING SYSTEMS He in Energy_Size Insul
System Name Distribution Type 'Type Sys Factor (gal) R -Val
Std Gas 50 gal or Less Recirc-Time&Temp Storms 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- -- -- ----- ----- --=-- -----
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 o.0 0
SPECIAL FEATURES/REMARKS
COMPLIANCE STATEMENT
This Certificate of Compliance lists the Building features and performance
specifications needed to comply with Title 24, Parts 1 & 6 of the Califor-
nia.Code of Regulations, and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single Building plan to be built in multiple orientations, a6y shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
(Per Business & Professions Code)
Shenasi Design
P.O. Bok 2771
Palm Desert, CA 92261
( 760 ) 779-5996 Lic V
wignature )
ENFORCEMENT
Name:
Title:
Agency:
Telephone:_
AGENCY
( date )
,DOCUMENTATION AU'T'HOR
Tit Scott
BREEZE AIR CONDITIONING
75-145 ST CHARLES PLACE
PALM DESERT, CA 92260
( 619 ) 346-0855 -
l
(signature) ( d to )
(signature/stamp) l date )
MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1H page 5 of 18
---------------------------------------------------------------------------
Project Mame: Donely Residence (Office Addition) ;Date: 9/12/1998
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES Enforcement -
o Sec. 150(a): Minimum R-19 ceiling insulation. *
o Sec. 150(b): Loose fill insulation manufacturers
labeled R -Value.
-o Sec. 150(c): Minimum R-13 wall insulation in framed walls
does not apply to exterior mass walls).
o Sec. 15o(d): Minimum R-13 raised floor insulation in framed
floors; Minimum R-8 in concrete raised floors.
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.30, water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec. 118: insulation specified or installed meets California
Energy Commission quality standards. indicate Type & form.
o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
,b. Manufactured fenestration products have label w/certified U -Value
c. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 1501): Special infiltration barrier installed to
comply with Sec. 151 meets Commission quality standards. _
o Sec. 150(e): Installation of Fireplaces, Decorative Gas
Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST ( part 2 of 2 ) MF -1R page 6 of 18
------------------------------------------------------ ----------------------
Project Name: Donely Residence (office Addition) ;Date: 9/12/1.998
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads
and taucets certified by the Commission.
o Sec. -150(i): Setback thermostat on all applicable
heating systems.
o Sec.. 150 j): Pipe and Tank Insulation -
1. Indirect hot water tanks (eg unfired storage tanks or
backup solar hot water tanks) have insulation blanket
(R-12 or greater) or,combined interior/exterior insulation
(R-16 or greater).
2. First 5 feet of pipes closest to water heater tank,
non -recirculation systems, insulated (R-4 or greater.
3. All buried or exposed piping insulated in recirculation
sections of hot water system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between heating source and indirect hot
water tank.
o Sec.
1
2.
3.
1.50(m) Ducts and Fans * -
Ducts'constructed, installed and sealed to comply with'
UMC Sections 1002 and 1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
Exhaust systems have backdraft or automatic dampers.
Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers.
o Sec. 114:Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
.2. System is installed with:
a. At least 36'` pipe between filter and heater for future
solar heating.
b'. cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 115: Gas-fired central furnace, pool heater, spa heater
or household cooking appliance have no continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES ,
o Sec. 150(k)' Lighting - 40 lumens/watt or greater for
general lighting in kitchens and rooms with water closets;
and recessed ceiling fixtures TC (insulation cover) approved.
*** BUILDING COMPLIES ***
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Occupancy Type:
Building Front orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
COMPLY 24 version 5.10
15
130 sgft
Addition
Single F•am Det
90 deg ( E')
1
1
Slab on Grade
1073 cuft
130 sqf t
.130 sgft
BUILDING ZONE INFORMATION
Floor ## of Vent
Zone Name Area Volume Units Zone Type T'Stat Type Hgt Area
- ----- ------ ------------------------------ ----
Ofifice Add Zone 130 1073 1.00 Conditioned Setback < 2 n/a
OPAQUE SURFACES Act Solar
Type Area U -Val Azm Tilt Gains Form 3 Reference Location/Comments
---- ---- ----- --- ---- ---------------------------- ---------------------
ZONE NAME = Office Add Zone
Wall
107
0.059
0
COMPUTER METHOD SUMMARY ( part 1 of 3 )
Yes
C -2R
page 7 of 18
Project Name: Donely Residence (Office
Addition)
;Date:
9/12/1998
Documentation: BREEZE AIR CONDITIONING'
---------------------------------------------------------------------------
90
;COMPLY
24 User 3665
90
Standard
Proposed
Compliance
Source Energy Use (KBtu/sf-yr)
Design
Design
Margin
Space Heating.
3.35
3.11
0.24
Space Cooling
92.75
94.57
-1.81
Domestic Hot Water
112.54
110.03
2.51
TOTALS
208.65
207.71
0.93
*** BUILDING COMPLIES ***
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Occupancy Type:
Building Front orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
COMPLY 24 version 5.10
15
130 sgft
Addition
Single F•am Det
90 deg ( E')
1
1
Slab on Grade
1073 cuft
130 sqf t
.130 sgft
BUILDING ZONE INFORMATION
Floor ## of Vent
Zone Name Area Volume Units Zone Type T'Stat Type Hgt Area
- ----- ------ ------------------------------ ----
Ofifice Add Zone 130 1073 1.00 Conditioned Setback < 2 n/a
OPAQUE SURFACES Act Solar
Type Area U -Val Azm Tilt Gains Form 3 Reference Location/Comments
---- ---- ----- --- ---- ---------------------------- ---------------------
ZONE NAME = Office Add Zone
Wall
107
0.059
0
90
Yes
Wall
83
0.059
90
90
Yes
Wali
90
0.059'
180
90
Yes
Door
17
0.387
180
90
Yes
Wall
50
0.059
270
90
Yes
Room
130
0.629
0
22
Yes
R-21 Wall ( W .21 .2x6.16 ) office Addition
R-21 Wall (W.21.2x6.16) Office Addition
R-21 Wall ( W .21 .2x6.16 ) Office Addition
Solid wood Door office Addition
R-21 Wall (W.21.2x6.16) Office Addition
R-38 Roof(R.38.2x14.16) Office Addition
COMPUTER ME•T•HOD SUMMARY ( part 2
--------------------------___------------------------------------------------
of 3 )
C -2R page 8 of 18
Project Name= D6nely Residence
(Office
Addition)
;Date. 9/12/1998
Documentation: BREEZE AIR CONDITIONING
------------ ___W___________
-----------
_--_-____-------_---_---_-------
;COMPLY 24 User 3665
PERIMETER LOSSES F2-
Insulation
Type Length Factor
R -Val
Depth
Location/Comments
LUNE NAME = Office Add Zone
Exposed 6-0 0.90
0.0
U in
Office
Addition
Covered 40.0 0.72
0.0
U in
Office
Addition
FENESTRATION SURFACES
SC
Act
Glass
# Type Area Frame Div
---------------
U -Val
Azm Tilt
Only
Location/Comments
----- ----- ---
ZONE NAME = Office Add •Lone
-----
--- ----
-----
----- ---------------
1 Wdw Back (W) 33.3 Wood No
0.55
270 90
0.59
office Addition
INTERIOR & EXTERIOR SHADING
# Type Interior Shade Type
SC
Exterior
Shade
•T'ype Sc
1 Wow• Std Drape
0.78
None
T.00
� .
~ �
` COMPUTER METHOD SUMMARY (pert 3 of 3) C -2R page 9 of 18
�
------------------------------------------- ________--_-___________-�--_-___
� ProjectName: DonelyR/si`once 'Office Adc]i��ion' ` 'Date: 9/l2/I998
' /
Documentation: 8RE,EZE AIR CONDITIONING ' /COMPLY'24 User 3665
---------------------- 7 ----- ______-__-____-_______________-_
UVERHANGS/SIDE FINS
--Window-- -----Overhang------ --rLeft Fin--- ---Right Fin"-.
# ` Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Mt
-7 -- ____ ____ ---- ____ ____ _--_ ____ _--- ____ --------- ____
.
NONE � � ' .� .
THERMAL MASS Area Thick Heat Inside Location
Type ` (sf' (in' Cap Cond Form 3 Reference R-Vai' Comments
_____________ _-__ _____ ----- _-__ ----------------------- ______ --------
ZONE NAME = Office Add Zone
Exposed Slab 30 3.63 28 0_98 n/a O
Covered Slab 100 3.50 28 0:98 n/a2
'
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
-- ---------- ________________ ___------ ___________-_-_________
Furnaoe : 0.800 AFUE Ducts in Attic 4'2 SetBck Office Add Zone
SpltAirCond10'500 SEER Ducts in Attic 4'2 SetBok
`
'
Water No. Tank Ext.
WATER HEATING SYSTEMS � ' Heater in- Energy Size Insul
System NameDistribution Type Type Sys Factor (gal' R-Vai
�
----------------------- _________-_______- _______ __- ------ __-__
Std Gas 50 gal or Less Reciro_Time&Temp StorGao' 1 0'53 50.0 1210
.
AFUE `
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name . I System Type Of Input LOSS R -Val Light
Std Gas 50 gal or Less DomeaticHW 0'780 40000 0'040 O'O 0
SPECIAL FEATURES/REMARKS
`
ADJUSTMENT' FOR FRAMING
(1 /22.53) x (0.85) + (1./ 6.98) x (0.15)
Weight: 13.2 lb/sgft
Heat'Capacity:
0.059
TOTAL U -VALUE _
TOTAL R=VALUE =
0.059
16.89
• PROPOSED CONSTRUC*LbN ASSEMBLY
ENV -3 page 10
of 18
Project Name: Donely Residence
(office Addition) ;Date: 9/12/1998
Documentation: -BREEZE ATR CONDITIONING
---------------------------------------------------------------------------
;COMPLY 24 User
3665
COMPONENT DESCRIPTION
Assembly Name: R-21 Wall (W.21.2x6.16)
Assembly. Type: Wali
Assembly .tilt: 90 deg (Vertical)
Framing Material: Wood
Framing Spacing: _`' O.C..
i
Framing Percent: 15.0
Absorptivity: 0.70
Sketch of.Construction Assembly
Roughness: Stucco, Wood Shingles
ASSEMBLY U -VALUE
Th R -Value
• Construction Components
Fr (in) Cavity
Frame
Outside Air Fil.m
0.17
0.17
1 ._ Stucco
0.875 0.17
0.17
2. Membrane.' Vapor -Permeable Felt,
0.010 0.06
0.06
3. Insulation, Mineral Fiber,
R-21 * 5.500 .2.1.00
5.45
4. Gypsum or Plaster Board
0.500 0.45
0.45
5.
6
9 .
Inside Air Film
0.68
0.68';
Unadjusted R -Values 22.53
6.98
ADJUSTMENT' FOR FRAMING
(1 /22.53) x (0.85) + (1./ 6.98) x (0.15)
Weight: 13.2 lb/sgft
Heat'Capacity:
0.059
TOTAL U -VALUE _
TOTAL R=VALUE =
0.059
16.89
ADJUSTMENT FOR FRAMING
11 440.,81) x (0.90) + (1 /15.16) x (0.10)
weight
Heat Capacity=
c
10.8 .lb/sqf t
3.18
0.029
4
TOTAL U -VALUE = 0.029
T'O'NAL R -VALUE = '34.914
' PROPOSED CONSTRUCTION ASSEMBLY
ENV -3 page 11 of 18
Project Name= Donely Residence
(office Addition) ;Date: 9/12/1998.-
Documentation: BREEZE ATR CONDITIONING'
-----------------------------------------I__.__----------------
;COMPLY 24 User 3.665
COMPONENT DESCRIP T' ION
Assembly Name : R-38 Roof(R .38 .2x 14.16)
---------------------4
, .
Assembly, Type: Roof
Assembly Tilt= 22 deg (Tilted Up)
Framing'.Material= wood
Framing Spacing: O.C.
Framing Percent= 10.0
-------------------------------
Absorptivity: 0.70
Sketch ot-Construction Assembly
Roughness: Concrete; Asph. Shingies
ASSEMBLY U -VALUE
Th R -Value
Construction Components
----------------------------------------------------------------------------
Fr (in.) Cavity Frame
Outside Air Film
0.17 0.17
1. Tile Roofing
0:-500 0.13 0.13
2. Membrane, Vapor -Permeable Felt
01..010. 0.06 0.06
3.* Plywood.
0.500 0.62 0.62
4. Air Space
* 1.750 -0.77 1.73
5. Insulation, Mineral Fiber,
R-38 * 11.500 38.00 11.39
6. Gypsum or Plaster Board
0.500 0.45 0.45
9.
inside Air Film
• ---------------------------------------------------------------------------
0.61 0.61
Unadjusted R -Values 40.81 15.16
ADJUSTMENT FOR FRAMING
11 440.,81) x (0.90) + (1 /15.16) x (0.10)
weight
Heat Capacity=
c
10.8 .lb/sqf t
3.18
0.029
4
TOTAL U -VALUE = 0.029
T'O'NAL R -VALUE = '34.914
PROPOSED CONS'TRUC'TION ASSEMBLY
ENV -3 page 12 of 18
Project Mame: Donely Residence
(Office Addition) ;Date: 9/12/1398
Documentation: BREEZE ATR CONDITIONING
---------------------------------------------------------------------------
;COMPLY 24 User 3665
COMPONENT DESCRIPTION
-------------------------------
Assembly Name: carpeted Slab On Grade
Assembly Type: Floor
Assembly milt= 180 deg (Horizontal Floor)
Framing Material. None
Framing Spacing: _" O.O.
Framing Percent: 0.0
-------------------------------
Absorptivity: 0.00
Sketch of Construction Assembly
Roughness: Concrete, Asph. Shingles .
ASSEMBLY U -VALUE'
Th R -Value
Construction Components
Fr (in) Cavity .,Frame
---------------
Outside Air Film
0.17 0.17
1. Earth
24.000 4.00 4.00
2. Concrete, 140 lb,- Not Dried
3.500 0.28 0.23
3. Flooring, Carpet and Fibrous
Pad 0.250 2.08 2.08
4.
5.
6.
9..
Inside Air Film
---------------------------------------------------------------------------
0.92 0'.92
Unadjusted R—Values 7.45 7.45
ADJUS'I MEN'i* FOR FRAMING
1 / 7.45) x x1.00) + (1 / 7.45) x (0.00) _
Weight 210.9 lb/sgft
Heat Capacity: 42.19
0.134
1'O.TAL U -VALUE _
'TOTAL R -VALUE' _
0.134
7.45
'
`
^ PROPOSED CONSTRUCTION ASSEMBLY ` ENV -3 page 13 of 18'
__________________________________--________-_______-________-___--___-_-_-
.
Project Name. Dnnly Residence 'Office Addition - 'Date. 9/12/1998
'
Documentation: BREEZE AIR CONDITIONING /COMPLY 24 User 3665
`
____-___________-______________________--___________-_--_____________-__-___
-
'
COMPONENT DESCRIPTION Assembly Name: Fxposed Slab On Grade,
.
-------------------------------.
.
| . /
Assembly Type: Floor
| |
Assembly Tilt: 180 deg (Horizontal F�loor)
| � ' Framing Material: None '
Framing Spacing-. " D.C.
. . .
Framing Percent:' O'O %
Absorptivity: 0.00
____________-__-___-_-_______-_ '
`
� Sketoh of Construction Aoaembly Roughneoo: Concrete, Aeph' Shingles
^
ASSEMBLY U -VALUE
ADJUSTMENT FOR FRAMING .
(I / 5'37) x (l'OO)+ (l / 5'37' x '0'00)
. .
.
Weight: 2I8'8 lb/oqft
Heat Capacity' 42'17
'.
= 0,186
TOTAL U -VALUE = 0`186
=====
.
TOTAL R -VALUE = 5'37
Th
R -Value
construction 'Components'
---------------------------
� Fr (in)
Cavity
Frame
�_____________-_-_____-_______--__________---___
Outoide Air Film
0.17
0'17
1.* Earth �
24'000
4,00
4'00
2' Concrete, 140 lb",Not Dried '
� �� 3'500
0.28
0'28
3'
.
' ^
6' '
9'
Inside Air Film . � �
_______________________-____________________-_-__-______--__________-_-____
-� �
0.92
`
0.92
-
UnedjVsted R -Values
5'37
5'37
ADJUSTMENT FOR FRAMING .
(I / 5'37) x (l'OO)+ (l / 5'37' x '0'00)
. .
.
Weight: 2I8'8 lb/oqft
Heat Capacity' 42'17
'.
= 0,186
TOTAL U -VALUE = 0`186
=====
.
TOTAL R -VALUE = 5'37
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 14 of 18
Project Name:•Donely Residence (office Addition) ;Date: 9/12/1998
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
COMPONENT' DESCRIPTION Assembly Name:.Solid Wood Door
-------------------------------
Assembly Type: Door
Assembly'T'ilt: 90'deg (vertical)*
Framing Material: None
Framing Spacing: U.C.
Framing Percent: 0.0
Absorptivity: 0.70
Sketch.of Construction Assembly.' Roughness: Glass, Paint on Pine
ASSEMBLY U -VALUE
Th R -Value•
Construction Components Fr (in) Cavity Frame
---------------------------------------------------------------------------
outside Air Film U.17 0.17
1. Softwood, bouglas Fir -Larch 1-.750 1.73 1.73
2-.
3
4.
6.
7.
8..
9.
,Inside Air Film 0.68 0.68
---------------------------------------------------------------------------
Unadjusted R=Values 2.58 2.58
ADJUSTMENT• FOR FRAMING
ti / 2.58) x (1.60) + (1 / 2.58) x (0.00)
Weight:
Neat Capacity:
5`.1 ib/sqft
1.'99
0.387
TOTAL U -VALUE _
TOTAL R -VALUE _
0.387
2.58
HVAC SYSTEM HEATING & COOLING LOAD SUMMARY page 15 of 18
Project Name: ponely Residence, (Office Addition) °;Date: 9/12/1998
i
.Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
--------------------------------------------------------- -------
HVAC SYS'T'EM DESCRIPTION
HVAC System Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Fan Schedule:
Peak Load Method:
Relative Humidity:
ZONES ON THIS SYSTEM, PEAK.
----------------------- ----
Uttice Addition (Jan 12am)
TOTAL ZONE LOAD
Duct Gains & Losses:
Ventilation: U CFM)
Return Air Lighting Gain
Supply/Return Fan Gain:
TOTAL SYSTEM LUAU
SYSTEM OUTPUT AT DESIGN CONDITIONS
MAIN HEATING & COOLING SYSTEM
TOTAL SYSTEM OUTPUT
office Add Zone
Existing FAU
Existing Cond Unit
1
CA Daytime Fans
COINCIDENT
50
COOLING
HEATING PEAK SENSIBLE LATENT
------- ------------ ------
4464 (Aug 2pm) 3558 337
4464 3558 337
446 356
O ( U CFM) U 0
O
0 0
4910 3914 337
80000 42237 8581
80000 42237 8581
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will.heat or cool.this zone during the design conditions indicated.
These numbers include no safety tactor, and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note, that Sensible and Latent Cooling Loads are
indicated to allow for.accurate comparison with ma.nufacturer's output data.
RESIDENTIAL ZONE HEATING LOAD SUMMARY
---------------------------------------------------------------------------
page
16 of 18
Project Name: Donely Residence (Office'Addition)
•
'Date:
9/12/1998
Documentation: BREEZE AIR CONDITIONING
_---------------------------------------------------------
i
;COMPLY 24 User
3665
Zone Name
Office
Addition
Design Indoor Dry. Bulb Temperature^
70 F
Design Outdoor Winter Dry Bulb.Temperature:
32 F
Design Temperature Difference.
38 F
Conduction
Area
U -Value
TD
Btu/hr
R-21.Wall �W.21.2x6.16)
330.0° x
0.0592
x 38.0
= 742
Solid Wood Door
16.7 x
0.3872
x 33.0
= 245
Dual Bronze Default(R)
33.3 x
0.5500
x 38.0
= 697
R-38 Roof(R.38.2x14.16)
130.0 x
0.0286
x 38.0
- 142
Slab on Grade Perim =
6.0 x
42
- 249
Slab on Grade. Perim =
40.0 x
42
- 1660
lntltration: 1.00 x 0.018 x 130 sf
x 8.3 ft x
1.00 AC
x 38.0
= 728
T,0TAL
HOURLY HEAT
LOSS FOR
ZONE
4464
Heating AirFlow= 4464 Btu/hr /
E1 .Q7 x 35 f=
Delta*l' ),]
= 119
cfm
':• RESIDENTIAL ZONE COOLING LUAU SUMMARY
---------------------------------------------------------------------------
page
17 of 18
Project Name: Donely Residence (office
Addition)
;Date: 9/12/1998
Documentation: BREEZE AIR CONDITIONING
---------------------------------------------------------------------------
;COMPLY 24 User
3665
Zone Name:
Office Addition
Design Indoor Dry Bulb Temperature:
78 F
Design Outdoor Summer Dry Bulb Temperature:
112 F
Design Temperature Difterence:
34 F
Conduction
-----------------------
Area
------
U -Value
-------
DETD
Btu/hr
R-21 Wall (W.21.2x6.16)
330.0 x
0.0592
----
x 30.6
------
- 598
Solid Wood Door
16.7 x
0.3872
x 30.6
- 198
Dual Bronze Default(R )
33.3 x
10.5500
x 34.0
- 624
R-38 Roof(R.38.2x14.16)
130.0 x
0.0286
x 51.0
- 190
Infiltration: 1.00 x 0.018 x 130 sf
x 8.3 ft
x 1.00 AC
x 34.0
- 652
Shaded
Unshaded
Solar Gain Orient.
----------------------- ---------
Area SGF
_--
Area SGF
SC
Dual Bronze Default(R) West [
----
0.0 x 15 +
---- ---
33.3 x 73j
----
x 0.42
= 1032 -
Internal Bain Op Frac.
Area Heat
Gain
Conv.
Lighting 1.00 Z x
130.0 x
0.200 x
3.413
= 89
Equipment 1.00 x
130.0 x
0.100 x
3.413
- 44
Occupants 1.00 x
130.0 j
255 /
250
- 133
TOTAL'HOURLY SENSIBLE HEAT
GAIN FOR
ZONE
3558
Latent Gain Op Frac.
Area Heat
Gain
Conv.
Btu/hr
Equipment 1.00 x
130.0 x
0.000 x
3.413
- - U
Occupants 1.UO x
.130.0 x
255 /
250
= 133
infiltration: 1.00 x 130 sf x
8.3 ft x
1.00 AC x
0.190
= 204
TOTAL HOURLY
LATENT HEAT
GAIN FOR
LUNE
337
Cooling QrFlow: 3558 Btu/hr i
[1.07 x 23
F DeltaT )J
= 144
cfm
M
a
INS TALLA TION CERTIFICATE CF -6R page 18 of 18
Project Name: Donely Residence (office Addition) ;Date: 9/12/1998
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
1, the -undersigned, verify that the equipment listed in the category above
my signature is the actual equipment installed and that the equipment
meets or exceeds the requirements of the Appliance Efficiency Standards.
In -addition, 1 have verified that the equipment is equivalent to or more
efficient than,the equipment specified on the Certificate of Compliance
submitted to demonstrate compliance with the Energy Efficiency Standards
for Residential Buildings. -
HVAC -
Heat. Equip
CEC Certified Manuf,
Actual Distrib Type
Duct
Heat Heat
System Type
-----------
Make & Model Number
-----------------------
Eft. and'Location
----- --7-----------
RVai
----
Load Output
------ ------
Furnace
Existing FAU
0.800 Ducts in Attic
4.2
4910 80000
Cool. Equip
CEC Certified.Manuf.'
Actual Distrib
"Type
Duct
System Type.
-----------
-Make & Model -Number
-----------------------
Efficiency and Location
----------------------------
RVai
SpltAirCbnd
Existing Cond Unit
10.500 SEER Ducts in
Attic
_---
4.2
Signature Date Name
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insui
CEC Cert. MaKe & Model Distribution Type Type Sys Factor (gal) R-Vai
Std Gas 50 gal or Less Recirc-Time&Temp StorGas 1 0.53 50.0 .12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated. Stdby Tank Pilot
System Name. . System Type Eff Input Loss R -Val Light
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
FAUCETS & SHOWER HEADS
All faucets and showerheads are listed in the Commissions Directory of
Certified Faucets And Showerheads, pursuant to Title'24, part 6,
Subchapter 2, Section 111.
Signature
Date Name