BRES2015-0160t r
Carrier: _ Policy Number:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
I certify that in the performance of the work for which this permit is issued, I
t.
T4Obi
t0
t
VOICE (760) 777-7125
78-495 CALLE TAMPICO
DD "�
00
t a or e, I shall fo with
LA QUINTA, CALIFORNIA 92253
FAX (760) 777-7011COMMUNITY
Date { L Applicant:
DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
permit subjects the applicant to a civil penalty,of not more than five hundred dollars
BUILDING PERMIT
($500).:
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
(1 1, as owner of the property, or my employees with wages as their sole
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
compensation, will do the work, and the structure is not intended or offered for sale.
Date: 5/12/2015
Application Number: BRES2015-0160
INTEREST, AND ATTORNEY'S FEES.
Owner:
Property Address: 55221 RIVIERA
APPLICANT ACKNOWLEDGEMENT
VAN WILLIGEN, JAN H
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
APN: 775153012
the conditions and restrictions set forth on this application.
39 MASON POND PL
o
C)
Application Description: VAN WILLIGEN ADDITION
& INTERIOR REMODEL
THE WODDLANDS, TX 77381Zz
issued as a result of this application , the owner, and the applicant, each agrees to, and
Property Zoning:
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
z
Application Valuation: $500,000.00
following issuance of this permit.
(� I am exempt under Sec. B.&P.C. for this reason
0 S
not commenced within 180 days from date of issuance of such permit, or cessation of
h�
Applicant:
Contractor:
C)la+
m � E �
BOB EDWARDS CONSTRUCTION INCOR
BOB EDWARDS CONSTRUCTION
I COR: ry _
51-455 DESERT CLUB DRIVE
51-455 DESERT CLUB DRIVE
L
n n
LA QUINTA, CA 92253
LA QUINTA, CA 92253
c
7R
s;
(760)777-8202
--------------------------------
--------------------------------------------------------------
Uc. No.: 684857
LICENSED CONTRACTOR'S DEC ON
I hereby affirm under penalty of perjury that I lic ed er provisions of Chapter
9 (commencing with Section 7000) of Division 3 of B' si e s and Pr fessions Code,
and my License is in full force and effect. I
License CI ss: B 27 License No.: 684
Date: 11 b Contractor:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
ofrk for which this permit is issued.
ave and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
OWNER -BUILDER DECLARATION
Carrier: _ Policy Number:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
I certify that in the performance of the work for which this permit is issued, I
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
shall not employ any person in any manner so as b ome s 'e to the workers'
city or county that requires a permit to construct, alter, improve, demolish, or repair
compensation laws of California, and agree if I h u ec a subject to the
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
workers' comp sation provisions of Secti
comply w' h th se provisions.
00
t a or e, I shall fo with
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
Date { L Applicant:
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a'
permit subjects the applicant to a civil penalty,of not more than five hundred dollars
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL,
($500).:
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
(1 1, as owner of the property, or my employees with wages as their sole
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
compensation, will do the work, and the structure is not intended or offered for sale.
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706'OF THE LABOR CODE,
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
INTEREST, AND ATTORNEY'S FEES.
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
APPLICANT ACKNOWLEDGEMENT
are not intended or offered for sale. If, however, the building or improvement is sold
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
within one year of completion, the owner -builder will have the burden of proving that
the conditions and restrictions set forth on this application.
he or she did not build or improve for the purpose of sale.).
1. Each person upon whose behalf this application is made, each person at whose
(_) I, as owner of the property, am exclusively contracting with licensed contractors
request and for whose benefit work is performed under or pursuant to any permit
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
issued as a result of this application , the owner, and the applicant, each agrees to, and
State License Law does not apply to an owner of property who builds or improves
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
employees for any act or omission related to the work being performed under or
the Contractors' State License Law.).
following issuance of this permit.
(� I am exempt under Sec. B.&P.C. for this reason
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation. /`
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
I certify that I have read this application and state that th
I agree to comply with all city and county ordinances ani
constructs an hereby authorize representatives of th
mentionecyprogerty for inspection purposes.
Date: 15 Signature (Applicant or Agent)
rmation is correct.
t!3
�
4 'DESCRIPTION ""
FINANCIAL INFORMATION
"4; ACCOUNT: '-
QTY
YY` ",AMOUNTS
, x:. PAID '`
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$62.36
$0.00
_ PAID BY
METHOD =M
RECEIPT,# -,
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT, y `
'QTY,
AMOUNT.. ;
-PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.40
$0.00
` :PAID BY
" r METHOD`RECEIPT'#
CHECK #-
CLTD BY
_`DESCRIPTION
. . ,ACCOUNT
QTY,;
. 'AMOUNT
p
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
PAID BY
`" METHOD -
"RECEIPT #
CHECK #
CLTD BY
:> DESCRIPTION" �
_ACCOUNT -'
QTY
'AMOUNT �
"' ,: PAID"
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$0.00
': - PAID BY
METHOD, •
RECEIPT # .'
CHECK #
CLTD BY
Total Paid forADDITION: $371.73 $0.00
DESCRIPTIONr�ACCOUNT
QTY:
AMOUNT
PAID r`
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
2
$140.00
$0.00
PAID BYt ' . y ...
��'METHOD-
_
'•.RECEIPT# '"CHECK#':
'-
CLTD BY ,
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $0.00
DESCRIPTION'`
ACCOUNT
,QTY `
' AMOUNT'+.?;a
pPAID L '
PAID''DATE'
BSAS SB1473 FEE
101-0000-20306
0
$20.00
$0.00
�- PAID Bi' ' .
r METHOD,
,RECEIPT~# .
`CHECK #
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $20.00 $0.00
DESCRIPTIONS,.,
ACCOUNT-
'QTY;
.,; AMOUNT,-
;:'" `•PAID .
PAID.DATE
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$24.66.
$0.00
•',_ . `*":; PA64Y `• ._,
a
` ^ `METHOD " ' �''
_.
`'RECEIPT # `
CHECK #
-'CLTD"BY„
, DESCRIPTION
ACCOUNT =• *,
QTY+;
` ",AMOUNT,"
PAID
PAID DATE.
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600'
0
$10.16
$0.00
PAID BY 3, , .... , .-.
: i
,, ,
- "`METHOD' a .
• -RECEIPT #'- -
CHECK #
CLTD BY:
..; L; DESCRIPTIONi ..,•
ACCOUNT`
QTYE
AMO
COUNTPAID
PAID�DAT E
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0•
$145.03
$0.00
•PAID BY .,
-METHOD-..3
;RECEIPT #
'c .'CHECK #
CLTD BY=
r t DESCRIPTION
*.
J :ACCOUNT " `
QTY
-AMOUNT'
PAID x
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$0.00
fPAID,BY - .k
g... METHODrr _ y=
RECEIPT#
CHECK#
CLTD_BY
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00
bESCRIPTiON - ,
"ACCOUNT
,QTY
'.AMOUNT
• o. • PAID -
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$0.00
PAID BY :. -
METHOD s, ' ..
t- .. ' RECEIPT #
CHECK #
-CLTD BY
' 1DESCRIPTION 7- ,
ACCOUNTQTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600.
0
$4.83
$0.00
- PAID BY °.
METHOD + . ;:
RECEIPT #. '
" -CHECK #..
CLTD BY
,n .DESCRIPTION. ,
`",, , ,ACCOUNT .,
QTY;
`AMOUNT,, ._
PAID,
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
•PAID BY "
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION-"- °.
ACCOUNT-
QTY
:
AMOUNT "
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0.00
PAID BY
° METHOD '
RECEIPT.#
CHECK #
CLTD BY
DESCRIPTION .,,`
Ir
"- ACCOUNT
QTY
:� AMOUNT '
'PAID
,PAID DATE
VENT FAN
101-0000-42402
0
$60.45
$0.00
- ^ ry ,c•�i y,,PAID BY . #' Si "
METHOD
n RECEIPT # " ='
CHECK # `
CLTD BY
,?DESCRIPTION ' '. '
- ACCOUNT,
QTY;
AMOUNT �'
' PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$24.15
$0.00
PAID BY . ' is " --
METHOD .,
' '- RECEIPT #1,CHECK
#- r.
CLTD BY
Total Paid for MECHANICAL: $118.44 $0.00
DESCRIPTION
ACCOUNT, ' '
QTY,'
<' ," AMOUNT . `+
SPAID •-
PAID DATE
PATIO COVER, STD, OPEN
101-0000-42404
0
$97.17
$0.00
` PAID BY
METHOD _
RECEIPT # v
CHECK #
CLTD BY .
Y DESCRIPTION{
ACCOUNT
QTY`
' 'AMOUNT
i. -PAID
PAID, DATE
PATIO COVER, STD, OPEN PC
101-0000-42600
0
$95.72
$0.00
a ..
• w, „'- ? < PAID BY ,°'
•. r _ ..
;; ,. METHOD,,.,: -
�
�" , , RECEIPT #
", CHECK #
_
CLTD BY
Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00
' DESCRIPTION. '
ACCOUNT I
+,` CITY
AMOUNT ''
PAID a }` nT.
'PAID DATE-
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$108.75
$0.00
' �' PAID BY
_ METHOD
RECEIPT #
CHECK # "'°
{CLTD BY<°'
', + *DESCRIPTION "
x `?ACCOUNT ���, �n
Q
AMOUNT: '
PAID
"PAID DATE.
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$87.00
$0.00
"PAID BY, r r f, '"
':`.' METHOD `, `'
iNRECEIPT,#
_CHECKIW,
CLTD BY '
:DESCRIPTION„,
^n�A OU T
CC N
QTY'
AMOUNT.
', PAID
PAID:DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
Alp $Y V `,r = ”
`i METHODx , '. �.
_ RECEIPT:# a.+,. '
;.. CHECK #
CLTD BY'.
t .^,•'. 3 , ;- r_ ,q, ='
.
,.. S
OUNT
�.
r.PA_IDA00UNT.
PAID,DATEDESCRIPTION
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$0.00
4"•-, Y+PAID BY -.,w `. c ;
i
y
"'ME THOD. T
f
, `RECEIPT #
CHECK #
CLTD BY,
J
,
Total Paid forREMODEL: $379.94 $0.00
'PAID
'PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$65.00
$0.00
PAID;BY
METHOD
-RECEIPT#
CHECK #, -.
CLTD BY
Total Paid forSTRONG MOTION INSTRUMENTATION SMt $65.00 $0.00
TOTALS:��
.. r
Description: VAN WILLIGEN ADDITION & INTERIOR REMODEL
Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED
Applied: 4/27/2015 KNE
Approved: 5/12/2015 JJO
Parcel No: 775153012 Site Address: 55221 RIVIERA LA QUINTA,CA 92253
Subdivision: TR 21381-2 CM 064/031 CM 067/001 Block: Lot: 4
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $500,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: - KITCHEN, BATHROOM & MASTER BEDROOM REMODEL. ADD 1315Q.FT TO MASTER BEDROOM. ADDITIONAL ELECTRICAL &
REPLACEMENT OF ALL BATHROOM FIXTURES. 2013 CODES. TOTAL INTERIOR REMODEL.
Applied to Approved,?
Printed: Tuesday, May 12, 2015 1:28:34 PM 1 of 4
CRSYS7fM5
ADDITIONAL
CHRONOLOGY
`'CHRONOLOGY TYPE ." -
` ' " STAFF NAME r
ACTION DATE
COMPLETION DATE
NOTES
x , i
a"r_
PENDING STRUC APPROVAL
NOTE
JIM JOHNSON
5/8/2015
5/12/2015
-
APPROVED
PROCESSED ON 4/27. CONDO ADDRESS INFO NEEDED TO BE
NOTE
KAY HENSEL
4/27/2015
4/27/2015
INPUT INTO SYSTEM. SENT TO YOUNG FOR STRUC. P/C DUE
BACK 5/8/2015
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
5/11/2015
5/11/2015
STRUC. APP. 5/8/2015
RECEIVED
PLAN CHECK SUBMITTAL
KAY HENSEL
4/27/2015
4/27/2015
APPLICATION RECEIVED AT FRONT COUNTER ON 4/24/2015.
RECEIVED
PROCESSED ON 4/27/2015. SENT TO YOUNG FOR STRUC P/C
TELEPHONE CALL
JIM JOHNSON
5/12/2015
5/12/2015
CALLED BOB EDWARDS TO INFORM HIM PLANS ARE READY
TO ISSUE, HAVE SCHOOL FEE LETTER READY FOR HIM.
CONDITIONS
Printed: Tuesday, May 12, 2015 1:28:34 PM 1 of 4
CRSYS7fM5
. Printed: Tuesday, May 12, 2015 1:28:34 PM 2of4 ' 0TWlYS7EM5
CONTACTS
Z-NAMf TikfJ��!,!_
-Y
INFORMATION
ADDRESS1_','
°bTY,,, STATE
ZIP..'
PHONE
FAX
4dTY,"
AMOUNT,
PAIP,��
PAID DATE
RECEIPT#'
_,.CHECK#�
ME TH'OD
�A ID BY
CLTD,
APPLICANT
BOB EDWARDS CONSTRUCTION
51-455 DESERT CLUB
LA QU I NTA CA
92253
INCOR
DRIVE
ADDITION, EA
101-0000-42400
0
$62.36
$0.00
CONTRACTOR
BOB EDWARDS CONSTRUCTION
51-455 DESERT CLUB
LA QUINTA CA
92253
ADDITIONAL 500 SF
INCOR
DRIVE
OWNER
I
VAN WILLIGEN, JAN H
39 MASON POND PL
I
-THE TX
77381
$0.00
WODDLANDS
ADDITIONAL 500 SF PC
. Printed: Tuesday, May 12, 2015 1:28:34 PM 2of4 ' 0TWlYS7EM5
FINANCIAL
INFORMATION
,DESCRIPTION ''
I ACCOUNT
4dTY,"
AMOUNT,
PAIP,��
PAID DATE
RECEIPT#'
_,.CHECK#�
ME TH'OD
�A ID BY
CLTD,
BY
ADDITION, EA
101-0000-42400
0
$62.36
$0.00
ADDITIONAL 500 SF
ADDITION, EA
101-0000-42600
01
$17.40
$0.00
ADDITIONAL 500 SF PC
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
ADDITION, FIRST 100 SF
101-0000-42600
0
$171.14
$0.00
PC
Total Paid forADDITION: $371.73 $0.00
HOURLY PLAN CHECK -
101-0000-42600
2
$140.00
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $0.00
BSAS SB1473 FEE
I - 101-0000-20306
1 0
$20.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION $20.00 $0.00
BSA:
RESIDENTIAL, EA
101-0000-42403
0
$24.66
$0.00
ADDITION 1,000SF
RESIDENTIAL, EA
101-0000-42600
0
$10.16
$0.00
ADDITION 1,000SF, PC
. Printed: Tuesday, May 12, 2015 1:28:34 PM 2of4 ' 0TWlYS7EM5
• '
{DESCRIP.TION "'
:; . ,_'
ACCOUNT,
IQTY :
-AMOUNT
�:;
PAID
"`PAID DATE
':RECEIPT#
. • ,
CHECK#
METHOD
PAID BY .
CLTD
RESIDENTIAL, FIRST
101-0000-42403. '
0
$145.03
$0.00
1,000SF
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$0.00
. 1,000SF, PC
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00
APPLIANCE
101-0000-42402
0
$12.09
$0.00
REPAIR/ALTERATION
APPLIANCE
101-0000-42600
0
$4.83.
$0.00
REPAIR/ALTERATION PC
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0.00
VENT FAN
101-0000-42402
0
$60.45
$0.00
VENT FAN PC
101-0000-42600
0
$24.15 - .
$0.00
Total Paid for MECHANICAL: $118.44 $0.00
PATIO COVER, STD,
101-0000-42404
0
$97.17
$0.00
.OPEN
PATIO COVER, STD,
101-0000-42600
0
$95.72
$0.00
OPEN PC
Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00
REMODEL,EA
101-0000-42400
0
$108.75
$0.00
ADDITIONAL 5000 SF
REMODEL,
101-0000-42600
0
$87.00
$0.00
ADDITIONAL 5000 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$0.00
PC
Total Paid for REMODEL: $379.94 $0.00
Printed: Tuesday, May 12, 2015 1:28:34 PM 3 of 4 C97
SYSTEMS
SAIAN
cOF Ttlr� - - O S _Y ter'',-••Y•s. Y� a"" `+, ...r- M�"'K!' rr 'moi -� ";s^Y°"t "�!' �,K' :'" F '' 4„
,.r 'l a er_: S_. �t+',,+�.. '•s._`tti.-a•�'�i S' �1.�. �ti.-:.N��� ,R-..�:.-,c _�....s-'..�4'''J-,moi
`DESCRIPTION rACCOUNT ; QTY AMOUNT ,* PAID _: PAID DATE RECEIPT #' CHECK # METHOD PAID
CLTD'
a BY ?
SMI - RESIDENTIAL 101-0000-20308 0 $65.00 $0.00
Total Paid forSTRONG MOTION INSTRUMENTATION�SMk $65.00 $0.00
'01i m
`T•
w a . ,
1'
_ ._..
SEQID
IN SPECTION TYPE 'r-
" , INSPECTOR'.'- ' '
SCHEDULED
COMPLETED'
RESULT '
REMARKS
- = NOTES'
4_
r
DATE
FINAL"
BLD
REVIEW TYPE
REVIEWER
SENT DATE
= '
DUE DATE
Printed: Tuesday, May 12, 2015 1:28:34 PM 4 of 4 CR
SYSTEMS
REVIEW TYPE
REVIEWER
SENT DATE
= '
DUE DATE
RETURNED
STATUS'
REMARKS
. 4
.
- r
NOTES:
DATE
NON-STRUCTURAL
JIM JOHNSON
4/24/2015
5/8/2015
5/8/2015
APPROVED
PENDING STRUC APPROVAL
KATHRYN
4/24/2015
5/8/2015
5/8/2015
APPROVED
STRUCTURAL
SAMUELS
..,. n . ..
T 77-7
Printed: Tuesday, May 12, 2015 1:28:34 PM 4 of 4 CR
SYSTEMS
Bin #� City of La QUlnta
Building &r Safety Division
Permit �O P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
ProlectA.ddress: 55.-221.Riyiera Owner's Name: Jan &Terri Van Willi en
A. P. Number: 775-153-012 Address: 55-221 Riviera
Legal Description: ... City, ST, zip: La Quinta, CA 92253 `
•
Contractor: Bob Edwards Construction Tclgphone:: ( . " wzr
. .......
Address: 51-455 Desert Club Drive Project Description:
City, ST, zip: La Quinta, CA 92236 Proposed interior remodel kitchen
Telephone: 760-777-8202;: "r: <: r:"::4 remodel, master bedroom & bathroom remodel,.
addition to master bedroom (13f s ft.) ,added
State Lic. # City Lic Ifcl _ .
" e ectrka , &'replacement of all bathroom fixtures
Arch., Engr, Designer Gabriel Rios .
Address: 49901 Cinnabar Ln.
City., ST, zip Coachella, CA 92236.
Telephone: 760-485'-7431 Construction Type: V-13 Occupancy: R-3
State Lic. #ju£ .s�3t.: Project type (circle one): New Add'n Alter Repair Demo
.Name of contact Person: Gabriel Rios -Sq. Ft.: 131 s .ft. #Stories: 1 #Units:
Telephone # of Contact Person: 760-485-7431 Estimated Value of Project: $500,000.00 ,
_ APPLICANT,: DO.,NOT.WRITE BELOW THIS LINE
# Submittal Req'd Recd TRACKING TERMU
Plan Sets Plan Check submitted . tem Amount
Structural Calcs 1-- Reviewed,.ready,for corrections Plan Check Deposit
Truss Calcs. Called Contact Perron Plan Check Balance •
Title 24 Cales. cjA-- Plans picked up Construction
Flood plain plan Plans resubmitted Mechanical
Grading plan 2,d Review, ready for correct I Z Electrical
Subeontactor;List Called Contact Person511
Plumbing
Grant Deed Plans picked up S.M.I.
H.O.A. Approval Plans resubmitted Grading
IN HOUSE:- 'r° Review, ready for correctionstissue Developer Impact Fee
Planning Approval Called Contact Person A.I.P.P.
Pub. Wks. Appr Date of permit issue
Schodl Fees
Total Permit Fees
Coachella Valley Unified School District This Box For District Use only
83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/MD. AMOUNT:
DATE: -- -
RECEIPT:
CHECK #:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Jan & Terri Van Willigen Date: May 12, 2015
Owner's Name: Phone No.
Project Address:. 55-221:Riviera, La Quinta, CA
Project Description: Room Addition
APN: 775-153-012 Tract #: Lot #'s:
Type of Development:. Residential XX Commercial Industrial
Total Square Feet of Building Area: 131 SQ.:FT
Certification of Applicant/Owners: The person signin certi th the ab formation is correct and makes.this statement under
penalty of perjudanfurther represents that he/she is tho ed o si al o the owner/d eloper.
Dated: t %�.J Signature: `f
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code 'Project Agreement Existing Not Subject to Fee "
17620 65995. Approval Prior to 1/1/87 Requirement
- Note"
Number of Sq.Ft. 131 Pursuant to.AB 181 any room additions or enclosures of 500
s.f. or less are exempt from developer fees.
Amount per Sq.Ft. EXEMPT
Amount Collected 0.00
Building Permit Application Completed: Yes/No:-:
By: Elsa F. Esqueda, Director of Facilities and Maintenance
r'
Certificate issued by: Leticia Torres, Facilities Analyst Signatur
N
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FE ;AN STATE E OF FEES
Section 66020 of the Government, Code asserted by Assembly; Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of.the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, :the 90 days starts on the date hereof. - This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. .
vl\/:c/mydoes/de%, ees/certifieate ofcompliance form updated 3-2007 11/2010
BUILDING ENERGY ANALYSIS REPORT
ECREIVED
APR 24 2015
CITY ®IF LA QUINTA
iMUNITY DEVELOPMENT
1 �
PROJECT:
Van Willigan Residence
55-221 Riviera
La Quinta, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
In'su-form, Inc.
778.10 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
CITY OFLA:QUINTA
BUILDING & SAFETY DEPT.
APPR VED
FOR WMT�UCTION
Job Numbe
• l�A'
Date:
4/17/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
3
Ener Pro 6.4 by Ener Soft User Number: 2655 ID:
1
Report Prepared by:
Joan D. Hacker
In'su-form, Inc.
778.10 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
CITY OFLA:QUINTA
BUILDING & SAFETY DEPT.
APPR VED
FOR WMT�UCTION
Job Numbe
• l�A'
Date:
4/17/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
3
Ener Pro 6.4 by Ener Soft User Number: 2655 ID:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
EnergyPro 6.4 by EnergySoft Job Number. ID: User Number. 2655
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Van Willigan Existing Addition.xmi
CF1 R -PRF -01 '•
Page 1 of 9
GENERAL INFORMATION
01
Project Name Single Fam Detached
02
Calculation Description Title 24 Analysis
03
Project Location 55-221 Riviera
04
City La Quinta
05
Standards Version Compliance 2014
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-3b1 (694)
08
Climate Zone CZ15
09
Software Version EnergyPrd 6.4
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 2484
15
Number of Zones 2
16
Slab Area (FT2) 2484
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) 0
21
Glazing Percentage (%) 22.0%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
This compliance analysis is valid only for permit applications through December 31, 2014
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use Standard
(k6rDV/ft2-yr) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 3.48
4.52
-1.04
-29.9%
Space Cooling 226.68
225.59
1.09
0.5%
IAO Ventilation 0.00
0.00
0.00
0.0%
Water Heating 12.12
12.12
0.00
0.0% -
Photovoltaic Offset ----
0.00
0.00
Compliance Energy Total 242.28
242.23
0.05
0.0%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Window overhangs and/or fins
CF1 R -PRF -01'
Page 2of9•
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
— None --
Cooling System Verifications:
• — None --
HVAC Distribution System Verifications:
— None --
Domestic Hot Water System Verifications:
—None -
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating, , Margin Percent Improvement
Total Energy (kTDV/f2-yr)' 286.66 286.61 0.05 0.0%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Fam Detached
2484
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Living
Conditioned
Living Zone1
2353
10
DHW Sys 1
Addition
Conditioned
Living Zone1
131
10
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Van Willigan Existing Addition.xml
CF1 R -PRF -01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (W)
Window and Door
Area (W)
Tilt
(deg)
Status
Verified
Existing
Condition
Front Wall
Existing Living
Default Wall 1978 to 1991
90
Front
600
93.6873
90
Existing
No
Left Wall
Existing Living
Default Wall 1978 to 1991
180
Left
500
111.508
90
Existing
No
Rear Wall
Existing Living
Default Wall 1978 to 1991
270
Back
600
232.311
90
Existing
No
Right Wall
Existing Living
Default Wall 1978 to 1991
0
Right
900
49
90
Existing
No
Roof
Existing Living
Default Roof 1978 to Pres
2353
Existing
No
Front Wall 2
Addition
R-13 Wall1
90
Front
5
90
New
N/A
Rear Wall 2
Addition
R-13 Wall1
270
Back
250
59.0026
90
New
N/A
Right Wall 2
Addition
R-13 Wall1
0
Right
150
90
New
N/A
Left Wal
Addition
R-13 Wall1
180
Left
150
90
New
N/A
Roof 2
Addition
R-38 Roof Attic
131
New
N/A
ATTIC
01
02
03
04
05
06
07
08
09
Name
Construction
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool Roof
Status
Verified
Existing
Condition
Attic Existing Living
Attic Roof Cons Existing
0
0.1
0.85
No
No
Existing
No
Attic Addition
Attic Roof Cons Addition
0
0.1
0.85
Yes
No
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Van Willigan Existing Addition.xml
CF1 R -PRF -01,,
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Front Wall (Front -90)
3.0
6.8
0.98
20.0
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 2
Front Wall (Front -90)
5.0
3.5
1
17.5
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 3
Front Wall (Front -90)
1.0
1.0
1
1.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 4
Front Wall (Front -90)
3.5
3.1
1.207
13.1
0.71
0.73
Insect Screen (default)
Existing
No
Window 5
Front Wall (Front -90)
3.5
7.0
1
24.5
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 6
Front Wall (Front -90)
1.3
7.0
0.967
8.8
0.42
0.26
Insect Screen. (default)
Altered
N/A
Window 7
Front Wall (Front -90)
1.3
7.0
0.967
8.8
0.42
0.26
Insect Screen (default)
Altered
N/A .
Window 8
Left Wall (Left -180)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 9
Left Wall (Left -180)
1.4
2.0
0.964
2.7
0.71
0.73
Insect Screen (default)
Existing
No
Window 10
Left Wall (Left -180)
5.0
3.5
1
17.5
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 11
Left Wall (Left -180)
3.0
6.8
0.98
20.0
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 12
Left Wall (Left -180).
3.9
4.8
0.956
17.9
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 13
Rear Wall (Back -270)
3.9
4.8
0.956
17.9
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 14
Rear Wall (Back -270)
10.0
8.0
1
80.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 15
Rear Wall (Back -270)
12.0
8.0
1
96.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 16
Rear Wall (Back -270)
10.0
3.9
0.985
36.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 17
Right Wall (Right -0)
8.0
5.0
1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 18
Right Wall (Right -0)
3.0
3.0
1
9.0
0.42
0.26
Insect Screen (default)
Altered
N/A
Window 19
Rear Wall 2 (Back -270)
6.0
8.0
1
48.0
0.42
0.26
Insect Screen (default)
New
N/A
Window 20
Rear Wall 2 (Back -270)
2.9
2.0
1.897
11.0
0.42
0.26
Insect Screen (default)
New
N/A
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Input File Name: Van Willigan Existing Addition.xml
CF1 R -PRF -01;
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
_
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right `
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 9
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 10
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 11
2
0.1
2
2
0
0
0
.0
0
0
0 0
0
Window 12
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 13
2
0.1
2
2
0
0
0
0
0
0
0 0
1 0
Window 14
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 15
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 16
2'
0.1
2
2
0
0
0
0
0
0
0 0
01
Window 17
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 18
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 19
4
0.1
4
4
0
0
0
0
0
•0
0 0
0
Window 20
4
0.1
4
4
0
0
1 0
0
0
0
0 0
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Van Willigan Existing Addition.xml
CF1 R -PRF -01 .
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
135
None
0.8
No
Existing
No
• Cavity/Frame: no insul. /2x4 Top Chrd
Addition
131
15
2x4 Top Chord of Roof Truss @ 24
0.8
--Nol
• Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons Existing
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
• Exterior Finish: Wood
Default Wall "1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 ® 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
• Over Floor Joists: R-9.9 insul.
• Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss CEJ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons Addition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Walll
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (belowCavity/Frame:
R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
Existing Living
2353
135
None
0.8
No
Existing
No
Slab
Addition
131
15
None `
0.8
--Nol
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required ---
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Van Willigan Existing Addition.xml
CFI R -PRF -01, -
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
_
Name
System Type
`
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.5298 EF
40000-Btu/hr
0
0.04
WATER HEATING —HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Living Zone1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
2484
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Datelrime: 13:29, Fri, Apr 17, 2015
Input File Name: Van Willigan Existing Addition.xml
CF1 R -PRF -01r
Page 8 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
04
05
Efficiency
07
Multi -speed
09
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10.42
12
No
No
N/A
Duct Leakage
system
Location
Location
Bypass Duct
Status
Condition
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
8.0
Attic,
Attic
None
Existing
No
N/A
System 1
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 1Not Required
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-17 13:31:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:29, Fri, Apr 17, 2015
Input File Name: Van Willigan Existing Addition.xml
CFI R -PRF -01
Page 9 of 9
z
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan D. Hacker
Company:
Signature Dater
Insu-form, Inc.
4/17/2015
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/State ip:
Palm Desert, Ca 92211
Phone:
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible De n r Sign ture:
Gabriel Rios
j
Company:
Date Signed:
Rios Designs
0 / 3/ 015
Address:
License:
49-901 Cinnabar Lane
N/A
City/State/Zip:
Phone:
Coachella, CA 92236
760-485-7431
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Van Willigan Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
4/17/2015
Project Address
55-221 Riviera La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,484
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Slab Unheated Slab -on -Grade
- no insulation 2,353 Perim = 135'
Existing
Wall Wood Framed
R11 2,114
Existing
Roof Wood Framed Attic
R 19 2,353
Existing
Demising Wood Framed
R 13 1
Existing
Wall Wood Framed
R 13 496
New
Roof Wood Framed Attic
R 38 131
New
Slab Unheated Slab -on -Grade
- no insulation 131 Perim = 15'
New
FENESTRATION
Orientation Area(ft)
I Total Area: 546 Glazing Percentage: 22.0%1
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor: 0.42
Exterior Shades Status
Front (E) 79.6
0.420
0.26 2.0 none
Bug Screen Altered
Front (E) 14.1
0.710
0.73 2.0 none
Bug Screen Existing
Left (S) 56.1
0.710
0.73 2.0 none
Bug Screen Existing
Left (S) 55.4
0.420
0.26 2.0 none
Bug Screen Altered
Rear (tM 17.9
0.420
0.26 2.0 none
Bug Screen Altered
Rear (W) 214.4
0.710
a 73 2.0 none
Bug Screen Existing
Right (N) 40.0
0.710
0.73 2.0 none
Bug Screen Existing
Right (N) 9.0
0.420
a26 2.0 none
Bug Screen Altered
Rear (Kq 59.0
0.420
a26 4.0 none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
1 Central Furnace
78% AFUE
Split Air Conditioner 12.0 SEER
Setback Existing
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R -Value Status
Living Zone Ducted
Ducted Attic
8.0 Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
Ener Pro 6.4 by Ener Soft User Number: 2655
RunCode: 2015-04-17T13:34:19
ID: Pae 12 of 17
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance aDDroach used. Exceptions may aDDly. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ I 10.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF] R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ ] 50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ ] 50.0(c):
Minimum R-] 3 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-] 9 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class H vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ ] 50.0(e)] A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)] B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)] C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)l :
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in § 150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00) ] A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.06)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)] :
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than V4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)]0:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0(m)] 2.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ ] 50.0(m)]3:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(0)1 A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
b 2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§150.0(k)]A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § ] 50.0(k).
§I50.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
-2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with §150.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9 § 130.0 § 130.2, § 130.4 § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 130.0 § 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10 e .
§ 110.10(a)2:
Low-rise multi-famfly buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§I 10.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l :
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Van Willigan Residence
Date
4/17/2015
System Name
Living Zone
Floor Area
2,484
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 3,639
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK.
Heating System
Sensible
Latent CFM
Sensible
Output per System 100,000
50,573
2,455 963
41,786
Total Output Btuh 100,000
0
Output Btuh/s ft 40.3
2,920
2,054
Cooling System
01
0
Output Per System 60,000
0
0 0
0
Total Output Btuh 60,000
0
2,920
1 56,412
2,455
0
Total Output ons 5.0
2,054
Total Output Btuh/s ft 24.2
Total Output s ft/Ton 496.8
1 45,894
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow cfm
2,210
Existing 36,550
19,581
100,000
Airflow cfm/s ff
0.89
Airflow cfm/Ton
442.0
Outside Air O
0.0%
Total Adjusted System Output 1 36,550
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
19,581 100,000
Aug 3 PM F Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Outside Air
0 cfm Supply Fan
2,210 cfm
69 OF
69 OF 112 OF
WA ._
Heating Coil
111 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 79 / 68
Outside Air
0 cfm
79168 "F
OF 79 / 68 OF 64 / 63 OF
1_�._.._.._.1..�
Supply Fan Cooling Coil 65 / 63 OF
2,210 cfm
59.4% ROOM F
78 ! 68 OF
i
Energ Pro 6.4 by Energ Soft User Number. 2655 RunCode: 2015-0417T13:34:19 ID:
Page 17 of 17