Loading...
BRES2015-0160t r Carrier: _ Policy Number: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued, I t. T4Obi t0 t VOICE (760) 777-7125 78-495 CALLE TAMPICO DD "� 00 t a or e, I shall fo with LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011COMMUNITY Date { L Applicant: DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 permit subjects the applicant to a civil penalty,of not more than five hundred dollars BUILDING PERMIT ($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO (1 1, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. Date: 5/12/2015 Application Number: BRES2015-0160 INTEREST, AND ATTORNEY'S FEES. Owner: Property Address: 55221 RIVIERA APPLICANT ACKNOWLEDGEMENT VAN WILLIGEN, JAN H IMPORTANT: Application is hereby made to the Building Official for a permit subject to APN: 775153012 the conditions and restrictions set forth on this application. 39 MASON POND PL o C) Application Description: VAN WILLIGEN ADDITION & INTERIOR REMODEL THE WODDLANDS, TX 77381Zz issued as a result of this application , the owner, and the applicant, each agrees to, and Property Zoning: shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to z Application Valuation: $500,000.00 following issuance of this permit. (� I am exempt under Sec. B.&P.C. for this reason 0 S not commenced within 180 days from date of issuance of such permit, or cessation of h� Applicant: Contractor: C)la+ m � E � BOB EDWARDS CONSTRUCTION INCOR BOB EDWARDS CONSTRUCTION I COR: ry _ 51-455 DESERT CLUB DRIVE 51-455 DESERT CLUB DRIVE L n n LA QUINTA, CA 92253 LA QUINTA, CA 92253 c 7R s; (760)777-8202 -------------------------------- -------------------------------------------------------------- Uc. No.: 684857 LICENSED CONTRACTOR'S DEC ON I hereby affirm under penalty of perjury that I lic ed er provisions of Chapter 9 (commencing with Section 7000) of Division 3 of B' si e s and Pr fessions Code, and my License is in full force and effect. I License CI ss: B 27 License No.: 684 Date: 11 b Contractor: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ofrk for which this permit is issued. ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: _ Policy Number: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as b ome s 'e to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree if I h u ec a subject to the any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the workers' comp sation provisions of Secti comply w' h th se provisions. 00 t a or e, I shall fo with Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the Date { L Applicant: basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a' permit subjects the applicant to a civil penalty,of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, ($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO (1 1, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706'OF THE LABOR CODE, (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to within one year of completion, the owner -builder will have the burden of proving that the conditions and restrictions set forth on this application. he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made, each person at whose (_) I, as owner of the property, am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' issued as a result of this application , the owner, and the applicant, each agrees to, and State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to the work being performed under or the Contractors' State License Law.). following issuance of this permit. (� I am exempt under Sec. B.&P.C. for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. /` Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: I certify that I have read this application and state that th I agree to comply with all city and county ordinances ani constructs an hereby authorize representatives of th mentionecyprogerty for inspection purposes. Date: 15 Signature (Applicant or Agent) rmation is correct. t!3 � 4 'DESCRIPTION "" FINANCIAL INFORMATION "4; ACCOUNT: '- QTY YY` ",AMOUNTS , x:. PAID '` PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $0.00 _ PAID BY METHOD =M RECEIPT,# -, CHECK # CLTD BY DESCRIPTION ACCOUNT, y ` 'QTY, AMOUNT.. ; -PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00 ` :PAID BY " r METHOD`RECEIPT'# CHECK #- CLTD BY _`DESCRIPTION . . ,ACCOUNT QTY,; . 'AMOUNT p PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 PAID BY `" METHOD - "RECEIPT # CHECK # CLTD BY :> DESCRIPTION" � _ACCOUNT -' QTY 'AMOUNT � "' ,: PAID" PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 ': - PAID BY METHOD, • RECEIPT # .' CHECK # CLTD BY Total Paid forADDITION: $371.73 $0.00 DESCRIPTIONr�ACCOUNT QTY: AMOUNT PAID r` PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 2 $140.00 $0.00 PAID BYt ' . y ... ��'METHOD- _ '•.RECEIPT# '"CHECK#': '- CLTD BY , Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $0.00 DESCRIPTION'` ACCOUNT ,QTY ` ' AMOUNT'+.?;a pPAID L ' PAID''DATE' BSAS SB1473 FEE 101-0000-20306 0 $20.00 $0.00 �- PAID Bi' ' . r METHOD, ,RECEIPT~# . `CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $20.00 $0.00 DESCRIPTIONS,., ACCOUNT- 'QTY; .,; AMOUNT,- ;:'" `•PAID . PAID.DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $24.66. $0.00 •',_ . `*":; PA64Y `• ._, a ` ^ `METHOD " ' �'' _. `'RECEIPT # ` CHECK # -'CLTD"BY„ , DESCRIPTION ACCOUNT =• *, QTY+; ` ",AMOUNT," PAID PAID DATE. RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600' 0 $10.16 $0.00 PAID BY 3, , .... , .-. : i ,, , - "`METHOD' a . • -RECEIPT #'- - CHECK # CLTD BY: ..; L; DESCRIPTIONi ..,• ACCOUNT` QTYE AMO COUNTPAID PAID�DAT E RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0• $145.03 $0.00 •PAID BY ., -METHOD-..3 ;RECEIPT # 'c .'CHECK # CLTD BY= r t DESCRIPTION *. J :ACCOUNT " ` QTY -AMOUNT' PAID x PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 fPAID,BY - .k g... METHODrr _ y= RECEIPT# CHECK# CLTD_BY Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 bESCRIPTiON - , "ACCOUNT ,QTY '.AMOUNT • o. • PAID - PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $0.00 PAID BY :. - METHOD s, ' .. t- .. ' RECEIPT # CHECK # -CLTD BY ' 1DESCRIPTION 7- , ACCOUNTQTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600. 0 $4.83 $0.00 - PAID BY °. METHOD + . ;: RECEIPT #. ' " -CHECK #.. CLTD BY ,n .DESCRIPTION. , `",, , ,ACCOUNT ., QTY; `AMOUNT,, ._ PAID, PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 •PAID BY " METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION-"- °. ACCOUNT- QTY : AMOUNT " PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 PAID BY ° METHOD ' RECEIPT.# CHECK # CLTD BY DESCRIPTION .,,` Ir "- ACCOUNT QTY :� AMOUNT ' 'PAID ,PAID DATE VENT FAN 101-0000-42402 0 $60.45 $0.00 - ^ ry ,c•�i y,,PAID BY . #' Si " METHOD n RECEIPT # " =' CHECK # ` CLTD BY ,?DESCRIPTION ' '. ' - ACCOUNT, QTY; AMOUNT �' ' PAID PAID DATE VENT FAN PC 101-0000-42600 0 $24.15 $0.00 PAID BY . ' is " -- METHOD ., ' '- RECEIPT #1,CHECK #- r. CLTD BY Total Paid for MECHANICAL: $118.44 $0.00 DESCRIPTION ACCOUNT, ' ' QTY,' <' ," AMOUNT . `+ SPAID •- PAID DATE PATIO COVER, STD, OPEN 101-0000-42404 0 $97.17 $0.00 ` PAID BY METHOD _ RECEIPT # v CHECK # CLTD BY . Y DESCRIPTION{ ACCOUNT QTY` ' 'AMOUNT i. -PAID PAID, DATE PATIO COVER, STD, OPEN PC 101-0000-42600 0 $95.72 $0.00 a .. • w, „'- ? < PAID BY ,°' •. r _ .. ;; ,. METHOD,,.,: - � �" , , RECEIPT # ", CHECK # _ CLTD BY Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00 ' DESCRIPTION. ' ACCOUNT I +,` CITY AMOUNT '' PAID a }` nT. 'PAID DATE- REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $108.75 $0.00 ' �' PAID BY _ METHOD RECEIPT # CHECK # "'° {CLTD BY<°' ', + *DESCRIPTION " x `?ACCOUNT ���, �n Q AMOUNT: ' PAID "PAID DATE. REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $87.00 $0.00 "PAID BY, r r f, '" ':`.' METHOD `, `' iNRECEIPT,# _CHECKIW, CLTD BY ' :DESCRIPTION„, ^n�A OU T CC N QTY' AMOUNT. ', PAID PAID:DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 Alp $Y V `,r = ” `i METHODx , '. �. _ RECEIPT:# a.+,. ' ;.. CHECK # CLTD BY'. t .^,•'. 3 , ;- r_ ,q, =' . ,.. S OUNT �. r.PA_IDA00UNT. PAID,DATEDESCRIPTION REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $0.00 4"•-, Y+PAID BY -.,w `. c ; i y "'ME THOD. T f , `RECEIPT # CHECK # CLTD BY, J , Total Paid forREMODEL: $379.94 $0.00 'PAID 'PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $65.00 $0.00 PAID;BY METHOD -RECEIPT# CHECK #, -. CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMt $65.00 $0.00 TOTALS:�� .. r Description: VAN WILLIGEN ADDITION & INTERIOR REMODEL Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED Applied: 4/27/2015 KNE Approved: 5/12/2015 JJO Parcel No: 775153012 Site Address: 55221 RIVIERA LA QUINTA,CA 92253 Subdivision: TR 21381-2 CM 064/031 CM 067/001 Block: Lot: 4 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $500,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: - KITCHEN, BATHROOM & MASTER BEDROOM REMODEL. ADD 1315Q.FT TO MASTER BEDROOM. ADDITIONAL ELECTRICAL & REPLACEMENT OF ALL BATHROOM FIXTURES. 2013 CODES. TOTAL INTERIOR REMODEL. Applied to Approved,? Printed: Tuesday, May 12, 2015 1:28:34 PM 1 of 4 CRSYS7fM5 ADDITIONAL CHRONOLOGY `'CHRONOLOGY TYPE ." - ` ' " STAFF NAME r ACTION DATE COMPLETION DATE NOTES x , i a"r_ PENDING STRUC APPROVAL NOTE JIM JOHNSON 5/8/2015 5/12/2015 - APPROVED PROCESSED ON 4/27. CONDO ADDRESS INFO NEEDED TO BE NOTE KAY HENSEL 4/27/2015 4/27/2015 INPUT INTO SYSTEM. SENT TO YOUNG FOR STRUC. P/C DUE BACK 5/8/2015 PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 5/11/2015 5/11/2015 STRUC. APP. 5/8/2015 RECEIVED PLAN CHECK SUBMITTAL KAY HENSEL 4/27/2015 4/27/2015 APPLICATION RECEIVED AT FRONT COUNTER ON 4/24/2015. RECEIVED PROCESSED ON 4/27/2015. SENT TO YOUNG FOR STRUC P/C TELEPHONE CALL JIM JOHNSON 5/12/2015 5/12/2015 CALLED BOB EDWARDS TO INFORM HIM PLANS ARE READY TO ISSUE, HAVE SCHOOL FEE LETTER READY FOR HIM. CONDITIONS Printed: Tuesday, May 12, 2015 1:28:34 PM 1 of 4 CRSYS7fM5 . Printed: Tuesday, May 12, 2015 1:28:34 PM 2of4 ' 0TWlYS7EM5 CONTACTS Z-NAMf TikfJ��!,!_ -Y INFORMATION ADDRESS1_','­ °bTY,,, STATE ZIP..' PHONE FAX 4dTY," AMOUNT, PAIP,�� PAID DATE RECEIPT#' _,.CHECK#� ME TH'OD �A ID BY CLTD, APPLICANT BOB EDWARDS CONSTRUCTION 51-455 DESERT CLUB LA QU I NTA CA 92253 INCOR DRIVE ADDITION, EA 101-0000-42400 0 $62.36 $0.00 CONTRACTOR BOB EDWARDS CONSTRUCTION 51-455 DESERT CLUB LA QUINTA CA 92253 ADDITIONAL 500 SF INCOR DRIVE OWNER I VAN WILLIGEN, JAN H 39 MASON POND PL I -THE TX 77381 $0.00 WODDLANDS ADDITIONAL 500 SF PC . Printed: Tuesday, May 12, 2015 1:28:34 PM 2of4 ' 0TWlYS7EM5 FINANCIAL INFORMATION ,DESCRIPTION '' I ACCOUNT 4dTY," AMOUNT, PAIP,�� PAID DATE RECEIPT#' _,.CHECK#� ME TH'OD �A ID BY CLTD, BY ADDITION, EA 101-0000-42400 0 $62.36 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 01 $17.40 $0.00 ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $371.73 $0.00 HOURLY PLAN CHECK - 101-0000-42600 2 $140.00 $0.00 YES Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $0.00 BSAS SB1473 FEE I - 101-0000-20306 1 0 $20.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $20.00 $0.00 BSA: RESIDENTIAL, EA 101-0000-42403 0 $24.66 $0.00 ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $10.16 $0.00 ADDITION 1,000SF, PC . Printed: Tuesday, May 12, 2015 1:28:34 PM 2of4 ' 0TWlYS7EM5 • ' {DESCRIP.TION "' :; . ,_' ACCOUNT, IQTY : -AMOUNT �:; PAID "`PAID DATE ':RECEIPT# . • , CHECK# METHOD PAID BY . CLTD RESIDENTIAL, FIRST 101-0000-42403. ' 0 $145.03 $0.00 1,000SF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 . 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 APPLIANCE 101-0000-42402 0 $12.09 $0.00 REPAIR/ALTERATION APPLIANCE 101-0000-42600 0 $4.83. $0.00 REPAIR/ALTERATION PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 VENT FAN 101-0000-42402 0 $60.45 $0.00 VENT FAN PC 101-0000-42600 0 $24.15 - . $0.00 Total Paid for MECHANICAL: $118.44 $0.00 PATIO COVER, STD, 101-0000-42404 0 $97.17 $0.00 .OPEN PATIO COVER, STD, 101-0000-42600 0 $95.72 $0.00 OPEN PC Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00 REMODEL,EA 101-0000-42400 0 $108.75 $0.00 ADDITIONAL 5000 SF REMODEL, 101-0000-42600 0 $87.00 $0.00 ADDITIONAL 5000 SF PC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $0.00 PC Total Paid for REMODEL: $379.94 $0.00 Printed: Tuesday, May 12, 2015 1:28:34 PM 3 of 4 C97 SYSTEMS SAIAN cOF Ttlr� - - O S _Y ter'',-••Y•s. Y� a"" `+, ...r- M�"'K!' rr 'moi -� ";s^Y°"t "�!' �,K' :'" F '' 4„ ,.r 'l a er_: S_. �t+',,+�.. '•s._`tti.-a•�'�i S' �1.�. �ti.-:.N��� ,R-..�:.-,c _�....s-'..�4'''J-,moi `DESCRIPTION rACCOUNT ; QTY AMOUNT ,* PAID _: PAID DATE RECEIPT #' CHECK # METHOD PAID CLTD' a BY ? SMI - RESIDENTIAL 101-0000-20308 0 $65.00 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION�SMk $65.00 $0.00 '01i m `T• w a . , 1' _ ._.. SEQID IN SPECTION TYPE 'r- " , INSPECTOR'.'- ' ' SCHEDULED COMPLETED' RESULT ' REMARKS - = NOTES' 4_ r DATE FINAL" BLD REVIEW TYPE REVIEWER SENT DATE = ' DUE DATE Printed: Tuesday, May 12, 2015 1:28:34 PM 4 of 4 CR SYSTEMS REVIEW TYPE REVIEWER SENT DATE = ' DUE DATE RETURNED STATUS' REMARKS . 4 . - r NOTES: DATE NON-STRUCTURAL JIM JOHNSON 4/24/2015 5/8/2015 5/8/2015 APPROVED PENDING STRUC APPROVAL KATHRYN 4/24/2015 5/8/2015 5/8/2015 APPROVED STRUCTURAL SAMUELS ..,. n . .. T 77-7 Printed: Tuesday, May 12, 2015 1:28:34 PM 4 of 4 CR SYSTEMS Bin #� City of La QUlnta Building &r Safety Division Permit �O P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet ProlectA.ddress: 55.-221.Riyiera Owner's Name: Jan &Terri Van Willi en A. P. Number: 775-153-012 Address: 55-221 Riviera Legal Description: ... City, ST, zip: La Quinta, CA 92253 ` • Contractor: Bob Edwards Construction Tclgphone:: ( . " wzr . ....... Address: 51-455 Desert Club Drive Project Description: City, ST, zip: La Quinta, CA 92236 Proposed interior remodel kitchen Telephone: 760-777-8202;: "r: <: r:"::4 remodel, master bedroom & bathroom remodel,. addition to master bedroom (13f s ft.) ,added State Lic. # City Lic Ifcl _ . " e ectrka , &'replacement of all bathroom fixtures Arch., Engr, Designer Gabriel Rios . Address: 49901 Cinnabar Ln. City., ST, zip Coachella, CA 92236. Telephone: 760-485'-7431 Construction Type: V-13 Occupancy: R-3 State Lic. #ju£ .s�3t.: Project type (circle one): New Add'n Alter Repair Demo .Name of contact Person: Gabriel Rios -Sq. Ft.: 131 s .ft. #Stories: 1 #Units: Telephone # of Contact Person: 760-485-7431 Estimated Value of Project: $500,000.00 , _ APPLICANT,: DO.,NOT.WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING TERMU Plan Sets Plan Check submitted . tem Amount Structural Calcs 1-- Reviewed,.ready,for corrections Plan Check Deposit Truss Calcs. Called Contact Perron Plan Check Balance • Title 24 Cales. cjA-- Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2,d Review, ready for correct I Z Electrical Subeontactor;List Called Contact Person511 Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'r° Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue Schodl Fees Total Permit Fees Coachella Valley Unified School District This Box For District Use only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/MD. AMOUNT: DATE: -- - RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Jan & Terri Van Willigen Date: May 12, 2015 Owner's Name: Phone No. Project Address:. 55-221:Riviera, La Quinta, CA Project Description: Room Addition APN: 775-153-012 Tract #: Lot #'s: Type of Development:. Residential XX Commercial Industrial Total Square Feet of Building Area: 131 SQ.:FT Certification of Applicant/Owners: The person signin certi th the ab formation is correct and makes.this statement under penalty of perjudanfurther represents that he/she is tho ed o si al o the owner/d eloper. Dated: t %�.J Signature: `f SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code 'Project Agreement Existing Not Subject to Fee " 17620 65995. Approval Prior to 1/1/87 Requirement - Note" Number of Sq.Ft. 131 Pursuant to.AB 181 any room additions or enclosures of 500 s.f. or less are exempt from developer fees. Amount per Sq.Ft. EXEMPT Amount Collected 0.00 Building Permit Application Completed: Yes/No:-: By: Elsa F. Esqueda, Director of Facilities and Maintenance r' Certificate issued by: Leticia Torres, Facilities Analyst Signatur N NOTICE OF 90 DAY PERIOD FOR PROTEST OF FE ;AN STATE E OF FEES Section 66020 of the Government, Code asserted by Assembly; Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of.the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, :the 90 days starts on the date hereof. - This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. . vl\/:c/mydoes/de%, ees/certifieate ofcompliance form updated 3-2007 11/2010 BUILDING ENERGY ANALYSIS REPORT ECREIVED APR 24 2015 CITY ®IF LA QUINTA iMUNITY DEVELOPMENT 1 � PROJECT: Van Willigan Residence 55-221 Riviera La Quinta, CA Project Designer: Report Prepared by: Joan D. Hacker In'su-form, Inc. 778.10 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OFLA:QUINTA BUILDING & SAFETY DEPT. APPR VED FOR WMT�UCTION Job Numbe • l�A' Date: 4/17/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 3 Ener Pro 6.4 by Ener Soft User Number: 2655 ID: 1 Report Prepared by: Joan D. Hacker In'su-form, Inc. 778.10 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OFLA:QUINTA BUILDING & SAFETY DEPT. APPR VED FOR WMT�UCTION Job Numbe • l�A' Date: 4/17/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 3 Ener Pro 6.4 by Ener Soft User Number: 2655 ID: TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 12 Form MF -1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 17 EnergyPro 6.4 by EnergySoft Job Number. ID: User Number. 2655 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xmi CF1 R -PRF -01 '• Page 1 of 9 GENERAL INFORMATION 01 Project Name Single Fam Detached 02 Calculation Description Title 24 Analysis 03 Project Location 55-221 Riviera 04 City La Quinta 05 Standards Version Compliance 2014 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-3b1 (694) 08 Climate Zone CZ15 09 Software Version EnergyPrd 6.4 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2484 15 Number of Zones 2 16 Slab Area (FT2) 2484 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 21 Glazing Percentage (%) 22.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below This compliance analysis is valid only for permit applications through December 31, 2014 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard (k6rDV/ft2-yr) Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.48 4.52 -1.04 -29.9% Space Cooling 226.68 225.59 1.09 0.5% IAO Ventilation 0.00 0.00 0.00 0.0% Water Heating 12.12 12.12 0.00 0.0% - Photovoltaic Offset ---- 0.00 0.00 Compliance Energy Total 242.28 242.23 0.05 0.0% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 HERS Provider: Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Window overhangs and/or fins CF1 R -PRF -01' Page 2of9• HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: — None -- Cooling System Verifications: • — None -- HVAC Distribution System Verifications: — None -- Domestic Hot Water System Verifications: —None - ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating, , Margin Percent Improvement Total Energy (kTDV/f2-yr)' 286.66 286.61 0.05 0.0% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 2484 1 6 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Living Conditioned Living Zone1 2353 10 DHW Sys 1 Addition Conditioned Living Zone1 131 10 DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xml CF1 R -PRF -01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (W) Window and Door Area (W) Tilt (deg) Status Verified Existing Condition Front Wall Existing Living Default Wall 1978 to 1991 90 Front 600 93.6873 90 Existing No Left Wall Existing Living Default Wall 1978 to 1991 180 Left 500 111.508 90 Existing No Rear Wall Existing Living Default Wall 1978 to 1991 270 Back 600 232.311 90 Existing No Right Wall Existing Living Default Wall 1978 to 1991 0 Right 900 49 90 Existing No Roof Existing Living Default Roof 1978 to Pres 2353 Existing No Front Wall 2 Addition R-13 Wall1 90 Front 5 90 New N/A Rear Wall 2 Addition R-13 Wall1 270 Back 250 59.0026 90 New N/A Right Wall 2 Addition R-13 Wall1 0 Right 150 90 New N/A Left Wal Addition R-13 Wall1 180 Left 150 90 New N/A Roof 2 Addition R-38 Roof Attic 131 New N/A ATTIC 01 02 03 04 05 06 07 08 09 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Living Attic Roof Cons Existing 0 0.1 0.85 No No Existing No Attic Addition Attic Roof Cons Addition 0 0.1 0.85 Yes No New No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xml CF1 R -PRF -01,, Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Front -90) 3.0 6.8 0.98 20.0 0.42 0.26 Insect Screen (default) Altered N/A Window 2 Front Wall (Front -90) 5.0 3.5 1 17.5 0.42 0.26 Insect Screen (default) Altered N/A Window 3 Front Wall (Front -90) 1.0 1.0 1 1.0 0.71 0.73 Insect Screen (default) Existing No Window 4 Front Wall (Front -90) 3.5 3.1 1.207 13.1 0.71 0.73 Insect Screen (default) Existing No Window 5 Front Wall (Front -90) 3.5 7.0 1 24.5 0.42 0.26 Insect Screen (default) Altered N/A Window 6 Front Wall (Front -90) 1.3 7.0 0.967 8.8 0.42 0.26 Insect Screen. (default) Altered N/A Window 7 Front Wall (Front -90) 1.3 7.0 0.967 8.8 0.42 0.26 Insect Screen (default) Altered N/A . Window 8 Left Wall (Left -180) 8.0 6.8 0.982 53.4 0.71 0.73 Insect Screen (default) Existing No Window 9 Left Wall (Left -180) 1.4 2.0 0.964 2.7 0.71 0.73 Insect Screen (default) Existing No Window 10 Left Wall (Left -180) 5.0 3.5 1 17.5 0.42 0.26 Insect Screen (default) Altered N/A Window 11 Left Wall (Left -180) 3.0 6.8 0.98 20.0 0.42 0.26 Insect Screen (default) Altered N/A Window 12 Left Wall (Left -180). 3.9 4.8 0.956 17.9 0.42 0.26 Insect Screen (default) Altered N/A Window 13 Rear Wall (Back -270) 3.9 4.8 0.956 17.9 0.42 0.26 Insect Screen (default) Altered N/A Window 14 Rear Wall (Back -270) 10.0 8.0 1 80.0 0.71 0.73 Insect Screen (default) Existing No Window 15 Rear Wall (Back -270) 12.0 8.0 1 96.0 0.71 0.73 Insect Screen (default) Existing No Window 16 Rear Wall (Back -270) 10.0 3.9 0.985 36.4 0.71 0.73 Insect Screen (default) Existing No Window 17 Right Wall (Right -0) 8.0 5.0 1 40.0 0.71 0.73 Insect Screen (default) Existing No Window 18 Right Wall (Right -0) 3.0 3.0 1 9.0 0.42 0.26 Insect Screen (default) Altered N/A Window 19 Rear Wall 2 (Back -270) 6.0 8.0 1 48.0 0.42 0.26 Insect Screen (default) New N/A Window 20 Rear Wall 2 (Back -270) 2.9 2.0 1.897 11.0 0.42 0.26 Insect Screen (default) New N/A Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 HERS Provider: Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Input File Name: Van Willigan Existing Addition.xml CF1 R -PRF -01; Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 _ Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right ` Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 2 0.1 2 2 0 0 0 .0 0 0 0 0 0 Window 12 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 13 2 0.1 2 2 0 0 0 0 0 0 0 0 1 0 Window 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 16 2' 0.1 2 2 0 0 0 0 0 0 0 0 01 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 19 4 0.1 4 4 0 0 0 0 0 •0 0 0 0 Window 20 4 0.1 4 4 0 0 1 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xml CF1 R -PRF -01 . Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 135 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd Addition 131 15 2x4 Top Chord of Roof Truss @ 24 0.8 --Nol • Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Existing Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 • Exterior Finish: Wood Default Wall "1978 to 1991 Exterior Walls Wood Framed Wall 2x4 ® 16 in. O.C. R 11 0.103 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 • Over Floor Joists: R-9.9 insul. • Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss CEJ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Addition Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Walll Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (belowCavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab Existing Living 2353 135 None 0.8 No Existing No Slab Addition 131 15 None ` 0.8 --Nol New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 HERS Provider: Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Van Willigan Existing Addition.xml CFI R -PRF -01, - Page 7 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 _ Name System Type ` Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.5298 EF 40000-Btu/hr 0 0.04 WATER HEATING —HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Living Zone1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2484 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Datelrime: 13:29, Fri, Apr 17, 2015 Input File Name: Van Willigan Existing Addition.xml CF1 R -PRF -01r Page 8 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 04 05 Efficiency 07 Multi -speed 09 Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10.42 12 No No N/A Duct Leakage system Location Location Bypass Duct Status Condition HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 8.0 Attic, Attic None Existing No N/A System 1 specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 1Not Required Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 HERS Provider: Report Generated at: 2015-04-17 13:31:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 13:29, Fri, Apr 17, 2015 Input File Name: Van Willigan Existing Addition.xml CFI R -PRF -01 Page 9 of 9 z DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan D. Hacker Company: Signature Dater Insu-form, Inc. 4/17/2015 Address: CEA/HERS Certification Identification (If applicable): 77810 Las Montanas Road, Suite 201 City/State ip: Palm Desert, Ca 92211 Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible De n r Sign ture: Gabriel Rios j Company: Date Signed: Rios Designs 0 / 3/ 015 Address: License: 49-901 Cinnabar Lane N/A City/State/Zip: Phone: Coachella, CA 92236 760-485-7431 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-17 13:31:55 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Van Willigan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/17/2015 Project Address 55-221 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,484 Addition 0 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 2,353 Perim = 135' Existing Wall Wood Framed R11 2,114 Existing Roof Wood Framed Attic R 19 2,353 Existing Demising Wood Framed R 13 1 Existing Wall Wood Framed R 13 496 New Roof Wood Framed Attic R 38 131 New Slab Unheated Slab -on -Grade - no insulation 131 Perim = 15' New FENESTRATION Orientation Area(ft) I Total Area: 546 Glazing Percentage: 22.0%1 U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.42 Exterior Shades Status Front (E) 79.6 0.420 0.26 2.0 none Bug Screen Altered Front (E) 14.1 0.710 0.73 2.0 none Bug Screen Existing Left (S) 56.1 0.710 0.73 2.0 none Bug Screen Existing Left (S) 55.4 0.420 0.26 2.0 none Bug Screen Altered Rear (tM 17.9 0.420 0.26 2.0 none Bug Screen Altered Rear (W) 214.4 0.710 a 73 2.0 none Bug Screen Existing Right (N) 40.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 9.0 0.420 a26 2.0 none Bug Screen Altered Rear (Kq 59.0 0.420 a26 4.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status Living Zone Ducted Ducted Attic 8.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.4 by Ener Soft User Number: 2655 RunCode: 2015-04-17T13:34:19 ID: Pae 12 of 17 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance aDDroach used. Exceptions may aDDly. Review the respective code section for more information. Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 a . § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § I 10.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF] R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § ] 50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § ] 50.0(c): Minimum R-] 3 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-] 9 in 2x6 or 0.074 maximum U - factor). § I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class H vapor retarder shall be placed over the earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § ] 50.0(e)] A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)] B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device. § 150.0(e)] C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150.0(h)l : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00) ] A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary § 150.00)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.06)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)] : space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than V4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § I50.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)]0: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0(m)] 2. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § ] 50.0(m)]3: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing,in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. § 150.0(0)1 A: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. b 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: §110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9. §150.0(k)]A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § ] 50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: -2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with §150.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9 § 130.0 § 130.2, § 130.4 § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0. § 150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 130.0 § 130.1 § 130.4 § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §I50.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § 110.10 e . § 110.10(a)2: Low-rise multi-famfly buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice §I 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)l : The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Van Willigan Residence Date 4/17/2015 System Name Living Zone Floor Area 2,484 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 3,639 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK. Heating System Sensible Latent CFM Sensible Output per System 100,000 50,573 2,455 963 41,786 Total Output Btuh 100,000 0 Output Btuh/s ft 40.3 2,920 2,054 Cooling System 01 0 Output Per System 60,000 0 0 0 0 Total Output Btuh 60,000 0 2,920 1 56,412 2,455 0 Total Output ons 5.0 2,054 Total Output Btuh/s ft 24.2 Total Output s ft/Ton 496.8 1 45,894 Air System CFM per System 2,210 HVAC EQUIPMENT SELECTION Airflow cfm 2,210 Existing 36,550 19,581 100,000 Airflow cfm/s ff 0.89 Airflow cfm/Ton 442.0 Outside Air O 0.0% Total Adjusted System Output 1 36,550 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 19,581 100,000 Aug 3 PM F Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 2,210 cfm 69 OF 69 OF 112 OF WA ._ Heating Coil 111 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 79 / 68 Outside Air 0 cfm 79168 "F OF 79 / 68 OF 64 / 63 OF 1_�._.._.._.1..� Supply Fan Cooling Coil 65 / 63 OF 2,210 cfm 59.4% ROOM F 78 ! 68 OF i Energ Pro 6.4 by Energ Soft User Number. 2655 RunCode: 2015-0417T13:34:19 ID: Page 17 of 17