Loading...
12-0552 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12-0 0 00 0 552 Property Address: 5'5-2-93 RIVIERA APN: - 775-153-009- - - Application description: ADDITION - RESIDENTIAL. Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 12685 Applicant: T4ht 4 4 4" - BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: P //0 Owner: MINKLER, RODERICK & BETTY 55293 RIVIERA LA QUINTA, CA 92253 Contractor: EDWARDS CONSTRUCTION,INC, 51455 DESERT CLUB DRIVE LA QUINTA, CA 92253 (760)777-8202 Lic. No.: 684857 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/09/12 FA66"iJ .11 0 72012[ OF LA AUiNTA ------------------- -------------=--------------------------------------------------7-------------- _ LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: ode, and my Lic se is in full force and effect. Section 00 of Division 3 of the 8u inessan roU,, I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided Licen ^las B C27 se No.: 684 7 _ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is y /ate. f uactor: 1, issued. IX I have and will maintain workers' compensation. insurance, as required by Sention 3700 of the Labor YT Code, for the performance of the work for which this permit is issued. My workers' compensation ' OWNER -BUILDER DECLARATION - insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier GRANITE STATE Policy. Numbei WC1914223 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become ' ct to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or nd agree that, if I bec e s le o the orkers' compensation provisions of Section 3700 of the Labor C d , I sh II fo comp ith those provi ns, that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ate: � �A.pplicant: 1 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and , the structure is not intended or offeredfor sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL; AND SHALL ' ' Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being ` performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and c n ordinances and state,laws relating to bu' conp; y authorize rep r sentatives of this t to enter upon the above-mentioned prop ori pe do os . Date: Vature (Applicant or Agent): Application Number . . . . . 12-00000552 ------ Structure Information 157SF PATIO ENCL/VB/RES-3/CL A -FR [ENG] ----- Other struct info CODE EDITION 2010 FLOOD ZONE NO ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 157.00 Permit BUILDING PERMIT Additional desc . Permit Fee 144.00 Plan Check Fee 93.60 Issue Date Valuation . . . . 12685 Expiration Date 2/05/13 Qty Unit Charge Per Extension BASE FEE 45.00 11.00 9.0000 --------------------------- THOU BLDG 2,001-25,000 -------------------------------------- 99.00 ----------- Permit . . . ELECT - ADD/ALT/REM Additional desc ` Permit Fee . . . . 32.50 Plan Check Fee 8.13 Issue Date . . . Valuation 0 Expiration Date 2/05/13 Qty Unit Charge Per Extension BASE FEE 15.00. 157.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 5.50 16.00 .7500 PER ELEC DEVICE/FIXTURE-1ST 20 12.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date Valuation . . . 0 Expiration Date 2/05/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA. MECH VENT INST/ DUCT ALT 4.50 Special Notes and Comments -------------------------------- 157SF PATIO ENCLOSURE/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE ADDITION TO THE EXISTING CONDO FOOTPRINT AREA. 2010 CALIFORNIA BUILDING CODES. August 2, 2012 9:31.-06 AM AORTEGA Other Fees . . . . . - - -------------------------------------- . . . BLDG STDS.ADMIN (SB1473) 1.00 LQPERMIT Application Number ... . . . 12-00000552 ------------------ Other Fees .. . . ------------------------- . . . . . . ENERGY REVIEW ----------------- FEE 9.36 ~ STRONG MOTION (SMI) - RES 1.27 Fee summary ----------------- Charged ---------- Paid ---------- Credited Due Permit Fee Total 196.00 ------ .00 --- ---------- .00 196.00 Plan Check Total 106.61 .00 .00 106.61 Other Fee Total 11.63 .00 .00 11.63 Grand Total 314.24 .00 .00 314.24 LQPERMIT Bin # City of La Quanta Building a Safety Division P.Q. Box 1504,78-495 Calle Tampico Ca.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # 12 ProjectAddtess:�7S'7� 3 �/1 `Q``���G� Owner's Name:. A. P. Number. ! / S l 5 3 Q V Address: %5 S c. r cwc feectei y -o Legal Descriiptio`1n: �gnf's!.Jc75fin S`Kt�1LF4�t G� Contractor: tddb tdl Wc� �SA U "k � G �'1 �Vl City, ST, Zip: �t v�vvd'- tC�i'Cj�iZ�3 Tel hone - � &e` ? ; ;�:'s• eP ``'�� (� , , ( (G Address: s� TSS 11s -,r- 1- ujJ� 11 Project Description: City, ST, Zip: �ljtv�4-fin y?�S ✓ 1��� l T�I 0v-\ C,t.�--4 AQ, / Telephone: 7o w? . b)-O�� . y M, f!Lir_' State Lic. # : Cp $ 4 '?S'7 #; 3a k a, • Arch., Engr., Designer. I ��pl Q- kc k i 't +75, Address: a 6 90 A- Qha4 Ai kin ' City, ST, Zip: (R vY1[.l acyl CA Telephone: 7l �' 71 f % ,x State Lic. #:C.. l .g q % ( r- } ` , Name of Contact Person: Q 2A�& . r&sSq. Construction Type:. Occupancy: Project type (circle one): New Add'n' Alter Repair Demo Ft : S # Stories: l # Units: Telephone # of Contact Person: Z % d 1 �% �� oZ Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets 3 G Plan Check submitted Item Amount Structural Cales. ,2 Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs.Called Contact Person Plan Check Balance Tide 24 Calci. . Z Plans picked up l5 Construction Flood plain plan Plans resubmitted.. 7 t*♦ Mechanical Grading plan r! Review, ready for correction Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. ILOAL Approval Plans resubmitted ;Grading IN ROUSE:- '^' Review', ready for correetiMIsue, 0e eloper Impact Fee Planning Approval Called Contact Person A.I.P.P' Pub. Wks. Appr Date of permit issue �. School Fees Total Permit Fees Is�11 dam*-- ------------- CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDADUNES r V) RANCHO MIRAGE Date 8/9/12 La Quinta, CA 92253 ,, INDIANWELLS c.. PALM DESERT No. 31360 (760) 771-8515 v>J, 111ND�y 3Q.IIO 0 .(.�� Owner Roderick & Betty Minkler APN # 775-153-009 Address 55293 Riviera Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 55293 Riviera Unit 2 Unit 3 Unit 4 Unit 5 Comments Patio enclosure 157 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 157 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Bob Edwards Check No. Name on the check Telephone 760-777-8202 Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected /exempt by-- n MC vrey Payment Recd z $0.00 f l fffjjj 7,;Over/Under'. ®... Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting ;eC . PGA WEST - RESIDENTIAL ASSOCIATION, INC. Page 1 of 2 August 8, 2012 Mr. & Mrs. Rod Minkler R r I P.O. Box 607 Orland, CA 95963-0607 AUG 0 9 2012 RE: 55-293 Riviera -Room Addition _ BY: Dear Mr. & Mrs. Minkler, The Architectural Committee has reviewed your resubmitted Architectural Variance request. The proposed exterior modifications to your unit as shown on drawings dated July 1, 2012, sheets, A.001, A.101, A.201, A-301, A-401, A.402, S-1, S-2, SD -1, SD -2, ST -1 and S -N August 18, 2010, sheets CS, 1-5 and EM -1, prepared by Andrade Architects, Inc. are acceptable. The interior renovations are not part of our review. The requirement to maintain the existing structural integrity and compliance with the building code is the responsibility of the homeowner's and their respective architect and engineer. The Homeowner's Association CC&R's. Architectural Guidelines and Maintenance and IndemniU Agreement apply to this variance. The following comments and requirements are applicable: . 1. Provide a copy of the City of La Quinta building department permit p for to starting any work. 2. Prior to starting any work, contact and set up a meeting with both the Maintenance Manager, William Aceves, to inspect roof area adjacent to the new work and the Landscape/Inigation Manager, Bill Bobbitt. 3. The contractor is not allowed to stockpile any material, equipment or construction debris in the street. 4. The street gutters are not to be used for concrete and construction material cleanup. The street is to be broom -washed, as needed each day during construction. Neither debris nor dirt is to be washed down the gutter. 5. The street and work area are to be kept clean daily. 6. The contractor is to observe all Association rules and regulations. Contractor's vehicles to be parked on one side of the street. 7. The contractor to repair and/or replace any damaged irrigation, landscape, hardscape, lights or street surface to the satisfaction of the HOA. All landscaped and/or hardscaped areas damaged or modified to have an approved plan reviewed by the HOA managers. 8. The new glazing to be a non -mirrored material and the color to match the existing. Samples are to be provided for glass and aluminum frames. 9. New stucco joints to existing to have proper paper, lathing tie-ins to prevent water intrusion. 54-320 Southern Hills, La Quinta, California 92253-5665, Telephone 760-771-1234 FAX 760-771-5125 _ lsy'r 10. The new flat roofing system to be a Polyurethane foam with coating to provide a ten-year. warranty. 11. All architectural details and finish to match the existing Fairway designs. 12. New paint to be Weathermaster Vista 1900 or equal hybrid elastomeric paint. Contact the HOA for paint color. 13. The, homeowner, the contractor, the landscape and maintenance managers to walk the project prior to filing a Notice of Completion form. 14. Upon completion, the homeowner is required to provide a signed copy of the city inspection card along with the Notice of Completion form and the Contractor's Notice of Completion Certification letter (enclosed). 15. A reasonable construction time is 90 days. 16. Any work requiring penetration or routing of lines in areas outside of the work area should be noted by the HOA maintenance manager for his information. 17. This review does not include any modifications not shown and specified on the file copy of plans. 18. The Homeowner, Architect and structural engineer should acknowledge the general soil's related issues within this area of PGA WEST and make provisions in the scope of work. 19. Maintenance and Indemnity Agreement to be signed at the beginning and reviewed at the conclusion of the project. Same shall delineate all applicable work, which current and future owners shall be compelled to solely maintain and/or replace as needed and the document shall be recorded with the County of Riverside and runs with the land. We reserve the right to make a final inspection of this change to make sure that it matches the original request. An approval is based only on the aesthetics of your proposed plan and should not be taken as any certification as to the construction worthiness or structural integrity of the proposed change. We appreciate your cooperation in. submitting this request for approval. If I may be of further assistance, please contact me at the HOA office at (760) 771-1234, Extension 15. Cordiall , C Ke cGalliard Operations Manager For the Architectural Committee KM/bvf Enc. 1 cc: Architectural Committee E N E R G -y- CODE CODE VV O R K S CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE ZaZgy Energy Code Works, Inc. Compliance Energy Standards i • Compliance Report Project: Addition/ Remodel to Minkler Residence 55293 Riviera La Quinta, Ca. 2600 Michelson Drive, Suite 1700 Irvine, Ca. 92612 CEPE Certified Energy Plans Examiners www.energycode.com plans@energvcode.com CHEERS Certified HERS Raters/HERS-PV Raters Compliance Summary P • Addition/Remodel to Minkler Residence 55293 Riviera La Quinta, Ca. Building Shell: New walls: R-13 batt insulation (2x4 framing) New windows: Dual pane/non-metal framing/no tint New patio doors:. Dual pane/non-metal framing/no tint HERS Measures: N/A HVAC - Existing VAC: Existing to remain Water heater: Existing to remain What you need to do: Sign the building designer statement on the Certificate of Compliance where indicated. Submit (2) copies of this report. Place the Certificates of Compliance (CF -1R & MF -1R) on the plans using tiff files inserted into the CAD drawing files. BUILDING ENERGY ANALYSIS REPORT PROJECT: Addition/Remodel to Minkler Residence 55293 Riviera La Quinta, Ca Project Designer: Andrade Architects Inc. 2880 South Coast Hwy. Laguna Beach, Ca 92651 (949) 715-7474 Report Prepared by: Mark Madison ENERGY CODE WORKS 2600 Michelson Drive Suite #1700 Irvine, Ca 92612 (949) 240-1867 =_ Z L CODE W O R www.enerpmde.com Job Number: 205311 Date: 7/6/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 201 s I TABLE OF CONTENTS i Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 10 13 r r r r CXBEI. YAP" AB� R08-07.1879 NR08-07-3578 JJJ�LLJ �J���..JJJ California Association of Building Energy Consultants H E `ERS Mark Madison r ce�tirzdKERS narel CERTIFIED ENERGY PIANS EXAMINER (WM 700-0131 - bum Mark Madison Mar<Madison R08-08-302 & NRO8-08.526='*"5i1%' 2008 Title -24 Building Efficiency Standards EnergyPro 5.1 by EnergySoft Job Number: ID: 205311 User Number: 1562 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 2F-1 R Project Name AdditioniRemodel to Minkler Residence Building Type m Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 7/6/2012 Project Address 55293 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,311 Addition 157 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST • Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. 0 Yes © No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Wall Wood Framed None 2,172 Existing Door Opaque Door None 60 Existing Roof Wood Framed Attic R-19 3,145 Existing Slab Unheated Slab -on -Grade None 3,154 Perim = 199' Existing Wall Wood Framed R-13 248 New Roof Wood Framed Attic R-19 157 New Slab Unheated Slab -on -Grade None 157 Perim = 75' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (lM 192.0 1.250 0.83 none none Bug Screen Existing Rear (VV) 25.0 1.190 0.83 none none Bug Screen Existing Rear (VV) 14.0 1.190 0.83 none none Bug Screen Existing Rear (Ko 41.0 1.190 0.83 none none Bug Screen Removed Rear (Vlq 128.0 1.250 0.83 none none Bug Screen Removed Left (S) 64.0 1.250 0.83 none none Bug Screen Existing Left (S) 32.0 1.280 0.80 none none Bug Screen Existing Left (S) 14.0 1.190 0.83 none none Bug Screen Existing Left (S) 18.0 1.190 0.83 none none Bug Screen Removed Left (S) 23.0 1.280 0.80 none none Bug Screen Removed Right (N) 15.0 1.190 0.83 none none Bug Screen Removed HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 72% AFUE Split Air Conditioner 9.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 2.1 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 1562 Run Code: 2012-07-06716:02:32 ID: 205311 Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Addition/Remodel to Minkler Residence Building Type m Single Family O Addition Alone O Multi Family m Existing+ Addition/Alteration Date 7/6/2012 Project Address 55293 Riviera La Quinta California Energy Climate Zoneond. CA Climate Zone 15 Floor Area 73,311 Addition 157 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 23.0 1.190 0.83 none none Bug Screen Existing Right (N) 64.0 1.250 0.83 none none Bug Screen Existing Skylight 9.0 1.980 0.83 none none None Existing Rear (M 210.0 0.530 0.60 2.0 none Bug Screen New Rear (10 42.0 0.580 0.65 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Energ Soft User Number.' 1562 Run Code: 2012-07-06716:02:32 ID: 205311 Page 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Addition/Remodel to Minkler Residence Building Type m Single Family O Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 7/6/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number.• 1562 Run Code: 2012-07-06716:02:32 ID: 205311 7777d 5 of 13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Addition/Remodel to Minkler Residence ❑ Multi Family m Existing+ Addition/Alteration 7/6/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 28.63 26.89 1.74 Space Cooling 284.25 266.56 17.69 Fans 46.26 43.38 2.87 Domestic Hot Water 13.74 13.74 0.00 Pumps 0.00 0.00 0.00 Totals 372.87 350.57 22.30 Percent Better Than Standard: 6.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 0 0 Fuel Available at Site: Natural Gas (S) 1,000 110 Raised Floor Area: 0 (M 1,260 483 Slab on Grade Area: 3,311 (N) 900 87 Average Ceiling Height: 8.0 Roof 3,311 9 Fenestration Average U -Factor: 0.98 TOTAL: 689 Average SHGC: 0.75 Fenestration/CFA Ratio: 20.8% REMARKS CA EB C STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed 808.07.1879 NR08-07-3578Mark to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Madison Efficiency Standards of the California Code of Regulations. CERTIFIED ENERGY PLANS ExAMfNER .,,. 2008 Title -24 Building Efficiency Standards The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author MARK MADISON Company ENERGY CODE WORKS CERTIFIED ENERGY PLANS EXAM ER I p— 7 6/2012 Address 2600 Michelson Drive Suite #1700 Name �a�rR�� City/State/ZipCity/State/Zip Irvine, Ca 92612 Phone (949) 240-1867 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Andrade Architects Inc. Address 2880 South Coast Hwy. Name c6-�4 " �/� %� -7'1,`/ ` 2, City/State/Zip Laguna Beach, Ca 92651 Phone (949) 715-7474 ned License # Date - Ener Pro 5.1 by Ener Soft User Number: 1562 RunCode: 2012-07-06T16:02:3 /D: 205311 Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Addition/Remodel to Minkler Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 7/6/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 451 0.356 None 270 90 Existing 4.3.1-A1 Existing Floor Area Door 40 0.500 None 270 90 Existing 4.5.1-A4 Existing Floor Area Door 20 0.500 None 270 90 1 Existing 4.5.1-A4 Existing Floor Area Wall 118 0.356 None 270 90 Existing 4.3.1-A1 Existing Floor Area Wall 91 0.356 None 270 90 Removec 4.3.1-A1 Existing Floor Area Wall 7901 0.356 None 180 90 Existing 4.3.1-A1 Existing Floor Area Wall 813 0.356 None 0 90 Existing 4.3.1-A 1 Existing Floor Area Roof 3,145 0.049 R-19 90 23 Existing 4.2.1-A4 Existing Floor Area Slab 3,154 0.730 None 0 180 Existing 4.4.7-A 1 Existing Floor Area Wall 148 0.102 R-13 270 90 New 4.3.1-A3 New Addition Area Wall 100 0.102 R-13 180 90 New 4.3.1-A3 New Addition Area Roof 157 0.048 R-19 0 0 New 4.2.1-A 16 New Addition Area Slab 157 0.730 None 0 180 New 4.4.7-A1 New Addition Area FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 64.0 1.250 Default 0.83 Default 270 Existing Existing Patio Door Existing Floor Area 2 Window 25.0 1.190 Default 0.83 Default 270 Existing Exist. Glass Block Existing Floor Area 3 Window 14.0 1.190 Default 0.83 Default 270 Existing Exist. Mitered Window Existing Floor Area 4 Window 64.0 1.250 Default 0.83 Default 270 Existing Existing Patio Door Existing Floor Area 5 Window 64.0 1.250 Default 0.83 Default 270 Existing I Existing Patio Door Existing Floor Area 6 Window 1 23.0 1. 1901 Default 0.83 Default 270 Removed Removed Fixed Pane Window Existing Floor Area 7 Window 64.0 1.250 Default 0.83 Default 270 Removed Removed Patio Doors Existing Floor Area 8 Window 64.0 1.250 Default 0.83 Default 270 Removed Removed Patio Doors Existing Floor Area 9 Window 18.0 1.190 Default 0.83 Default 270 Removed Removed Fixed Pane Window Existing Floor Area 10 Window 64.0 1.250 Default 0.83 Default 180 Existing Existing Patio Door Existing Floor Area 11 Window 16.0 1.280 Default 0.80 Default 180 Existing Exist. Operable Window Existing Floor Area 12 Window 16.0 1.280 Default 0.80 Default 180 Existing Exist. Operable Window Existing Floor Area 13 Window 14.0 1.190 Default 0.83 Default 180 Existing Exist. Mitered Window Existing Floor Area 14 Window 18.0 1.190 Default 0.83 Default 180 Removed Removed Fixed Pane Window Existing Floor Area 15 Window 23.0 1.280 Default 0.80 Default 180 Removed Removed Operable Window Existing Floor Area 16 Window 15.0 1.190 Default 0.83 Default 0 1 Removed Removed Fixed Pane Window Existing Floor Area (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 IBug Screen 0.76 16 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 1562 RunCode: 2012-07-06716:02:32 ID: 205311 Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Addition/Remodel to Minkler Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 7/6/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments -Cavity FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 23.0 1.190 Default 0.83 Default 0 Existing Exist. Glass Block Existing Floor Area 18 Window 64.0 1.250 Default 0.83 Default 0 Existing Existing Patio Door Existing Floor Area 19 Skylight 9.0 1.980 Default 0.83 Default 90 Existing Existing Skylight Existing Floor Area 20 Window 210.0 0.530 Default 0.60 NFRC 270 New New Patio Door New Addition Area 21 Window 42.0 0.580 Default 0.65 Default 270 New I New Operable Window New Addition Area (1) V -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len Hat 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 1.00 20 Bug Screen 0.76 21 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 1562 RunCode: 2012-07-06T16:02:32 ID: 205311 Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Addition/Remodel to Minkler Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration nate 7/6/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Existing HVAC Existing Floor Area 3,154 25,232 1980 New Addition Area 157 1,256 Totals 1 1571 3,1541 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing HVAC 1 Central Furnace 72% AFUE Split Air Conditioner 9.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Coolin Duct Location R -Value Ducts Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 2.1 ❑ Existing ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Existing water heater 1 Small Gas No Pipe Insulation 50,000 50 0.48 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)o <— System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ Ener Pro 5.1 by Ener Soft User Number: 1562 RunCode: 2012-07-06716:02:32 ID: 205311 Pa e 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Addition/Remodel to Minkler Residence Date 1 7/6/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number., 1562 Run Code: 2012-07-06716:02:32 ID: 205311 Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Addition/Remodel to Minkler Residence 1 7/6/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 1562 Run Code: 2012-07-06T16:02:32 ID: 205311 Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Addition/Remodel to Minkler Residence 1 7/6/2012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CABEI.i J �NR�0�8.07 R08-07.1879 3578 BEC CafoniaAoticnofBuildingEnergyConsultants vHEERIC Mark Madison MM Certified HERS Rater CERTIFIED ENERGY PLANS EXAMINER (800) 700-0131 Mark Madison Mark Madison ROB-08-302 & NRO8-08.526 2008 Title-24 Building Efficiency Standards EnergyPro 5.1 by EnergySoft User Number: 1562 RunCode: 2012-07-06716:02:32 ID: 205311 Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Addition/Remodel to Minkler Residence Date 7/6/2012 System Name Existing HVAC Floor Area 3,311 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 6,734 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 100,000 141,753 2,888 1,233 91,707 Total Output Btuh 100,000 0 Output Btuh/s ft 30.2 18,345 9,782 Cooling System 0 0 Output perSystem 60,000 0 0 0 0 Total Output Btuh 60,000 3,070 2,888 -3,070 Total Output Tons 5.0 18,345 9,782 Total Output Btuh/s ft 18.1 Total Output s ft/Ton 662.2 1 181,514 108,202 Air System CFM perSystem 2,100 HVAC EQUIPMENT SELECTION Airflow cfm 2,100 Existing HVAC 51,671 0 100,000 Airflow cfm/s ft 0.63 Airflow cfm/Ton 420.0 Outside Air % 0.0% Total Adjusted System Output 51,671 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK r 0 Aug 3 PM 100,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 4 Ar 68 OF 140 OF 141 OF O , Heating Coil Supply Fan 139 OF 2,100 cfm .COM _ 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 80/63°F 80/63°F 55/54°F 56/54°F c Cooling Coil Supply Fan 58 / 55 OF 2,100 cfm 41.9% ROOM 78/63°F _ I EnergyPro 5.1 by EnergySoft User Number: 1562 Run Code: 2012-07-06716:02:32 ID: 205311 Page 13 of 13