Loading...
9907-628 (AR)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date WOW V Date Signature of Contractor �0� L OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. J(') I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carver Policy No. TO �lftl� S U*i'vs�.i (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation . rovislons of Section 3700 of the Labor Coclg: shall forthwith complyi ith"tho provisions. VDa& Applican Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on. his application. . 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is corrects I agree to comply with all City, and State laws relating to the .building construction, and hereby author ze representatives of this City to enter upon t e above-mentioned property fqr In peotion purposes. r Signature (Owner/Agent)'�.a� �' "'" Dat `—f BUILDING PERMIT PERMIT# pp DATE � � VALUATION LOT TRACT JOB SITE� ADDRESS :r 3-�,� 4tlY Q i 1•sO A�P-N^► I aArW OWNERgg CONTRACTOR / DESIGNER / ENGINEER VV fR S13i:�LA W � 61110 110'.1,II C�ir�i't RD JdVii:RA ,420 FIESTAORIVE Y LA �,F'l ►it , A'A f...A Lill, QUINT A ( "A 9221,54 USE OF PERMIT s11j,J' iJ I/I it-_)& ilt.Jt)M MAA 1 it N '0) L"Q Ll� U.41 hi4ru tN t t, kA.z ^1 r��7194u..:i ysyn{�9,�A, K��fAw\1 E`9't.,4' �f a('>f•I �i •�.�i1%�9`}�.fD S. I-ILNv tHEt'K & EI, ii9ltt tt+ 4 /-3�t3 ?v t� t't1t4f!i`V'33'11(�'d"tt°►ldy^Sri: 9t)�-dst�O,�3f�t-i i�f� �°�.�tf�#� N1.,' I:!A4,fK'1'ti, FET, I'M Vis) N5,0"TIONFts etWAI+ 04 -AX0,141..{ti;4 :tib!fit-IAII'.F 1. C4ONSll-V 4`110N ANI) W-4 i Vi(a F`,I+ i Irl,8 14 2 isJ, Nil) .Y11 -I f`S . F RECEIPT DATE BY DATE FINALED IN INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O. K. to Wrap F.A.U. Framing Insulation Compressor Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath 40 Drywall - Int. Lath Final Final a POOLS - SPAS BLOCKWALL APPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Pibg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) Notice: Document Cannot Be Duplicated Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 760-771-8515 CERTIFICATE OF COMPLIANCE Date 7/30/99 APN # ,69-412-009 No. 19131 Jurisdiction La Quinta Owner NameRuby & Sheila Maggio Pernit # No. 55-515 Street Riviera Log # City La Quinta zip 92253 Study Area Tract # Lot # Square Footage .499 Type of Development Residential Addition No. of Units 1 Comments sq. ft. residential addition, room;,addition. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time ,due to the following reason: Residential Addition 500 Sq Feet or Less This certifies that school facility fees imposed pursuant to Government Code 53080 in t)Ve amount of 0.00 X 499 or $ 0.00 the property listed above-ardthat lauilding permits and/or Certificates of Occupancy for this square footage in this proposed project may novo be issued; Fees Paid By N/A - Bob Edwards Construction' _T'eaie '777 . •.iepho5-T933µ::. Name on the check �< W By Dr. Doris Wilson 7"r Superintendent Fee collected /exempted by Signature Juanita. Green Exempt Check No. N/A $0.00 NOTICE: Pursuant of Asser�ly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protestthe fees or other payment identified above will begin to run from a date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to collect them on the District('s)(s') behalf,. whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting a.+ 4 PGA WEST RESIDENTIAL ASSOCIATION, INC. August 3, 1999 Rudy & Sheila Maggio 55-515 Riviera La Quints, CA 92253 ; Dear Mr. and Mrs. Maggio: Thank you for submitting the architectural request to add a mom (ogre addition to be deme at a later time) to your 55-515 Riviera residence. Mr. Don Adolph, Architechual Committee C6ai_person, has approved the plan contingent upon compliance with the following con(titions. 1) Stucco, roof tyle and concrete work is to match the existing in color, style, texture, etc, 2) Bring plans up to date (ie., concrete work and elimination of office). 3) Owner is responsible for the location of new addition in relationship to rear property Ines. This committee assumes no responsibility if this dimension is not correct. 4) Trees are to be relocated as directed by Bill BOWL. If they don't survive neplwernem, trees and , installation are the responsibility of property ownr. 5) All existing electrical and irrigation systems w be relocated shall be done under direetion of the HOmeowners' Association. 6) Grass replacement shall be sod. Any and all grass/lawn/soil damage to adjacent neighbors by equipment brought in -shall be the responsibility of the property owner an cvntraor. This will be repaired to the satisfaction of the Homeowners' Association. We reserve the right to make a final inspection of this change to make sure that it matches the original request. An approval is bused only on the aesthetics of your proposed plan and should not be taken as any certification as to the construction worthiness or structural integrity of the proposed change. We appreciate your cooperation in submitting this request for approval. If I may be of further assistance, please contact we at the HOA office, (760) 771-1234, Ext 15. Sincere! Ke cGialliard Operations Manager cc: Architectural Committee P.O. BOX 1060, La Quinta, Califomia 92253, Telephone 760-7/14234 FAX 760-771-5125 ji �bA 0"AIJ�ON TANDY C/� O ' 4 RECp 37630 Medjool Ave. Palm Desert, CA 92211 SA'i ffice (760) 772-7192 • INSPECTION Fax (760) 772-7193' REGISTERED INSPECTOR'S WEEKLY REPORT Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE ❑ STRUCT. STEEL ASSEMBLY ❑ POST TENSIONED CONCRETE ❑ ASPHALT ❑ REINFORCED MASONRY ❑ FIRE PROOFING �w- 3�� ❑ OTHER JOB LOCATION 5 _ 5 15 J t E P -A �.. >pc &,,;J, C REPORT SEQUENCE N0. TYPE OF STRUeCLTUUREp S io 1 F-5 P%f� PERMIT NO. o�_ �-zo DATE Iw �a DAY OF WEEK MATERIAL � DESCRI N A3 o ARCHITECT R66c(,'1k, 'D INSPECTOR HRS. CHARGED ENGINEER ASSISTANTS HRS. CHARGED INSPECTION GENERAL Q CODATE CONTRACTOR 06 Fjo5 W N 9f, CONTRASUBCTOR a ! -p_ p�b�'cp-�� �Sc�M� � o Z e , 3`y o . RE 7 be-edw.�iv Lc r R ry E2 otJ 5a �'aP vbs€� ar�oi A -33 3 &---6AA we f � Z " �A Gt,J o a COPY SENT TO CLIENT ❑ CONTINUED ON NEXT PAGE O PAGE / OF / CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. SIGNA URE OFR GISTERED INSPECTOR 96 9 Tcao 11113z6 -Y? ATE OIF REPORT REGISTER NUMBER 'i' i T Lir 24 REPORT FOR Maggio Residence --Existing 55-515 Riviera La Quinta, Ca PROJECT DE=S'I'GNER= Robert A. Pitchford, Design & Drafting 41-625 Eclectic, Suite A-2 Palm Desert, Ca 92260 (/6 0 ) 346-2856 REPORT PREPARED BY: Tim Scott BREEZE AIR 'CONDITIONING 75-145 ST CHARLES PLACE ' PALM DESERT, CA 92260_ 6,19 j 346-0855 Job Number= Date= 10/1/1999 •The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This programhas approval and is authorized by the Cali-Fornia Energy Commission for use w_th both the Residentiai and Nonresidential Building Energy Efficienc- Standards. This -program -developed by Gabel Dodd/EnergySoifit, ilc 14=5j 883-5900. Table Of, Contents for title 24 Report ------------------------------------- CoverPage .................... .............................. ..... 1 `fable of Contents ..................... ...----..............-•----• 2 Form CF-1R Certificate of Compliance ................. .............. 3 Form MF-1F2; Mandatory Measures .Checklist .............................. 5 Form P-2k Point System Summary .........................:. ........... 7 "'Form C-2k Computer Method Summary (,Points) .. ........`.......... y Form ENV-3 Construction Assemblies 15 HVAC System Loads Summary 22 Lone Heating Loads Summary.......................................... 23 Zone Cooling Loads Summary 24 9 CERTIFICATE OF COMPLIANCE - Residential (part 1 --------------------------------------------------------------------------- of 2) CF -1R page'3 of 24 Project Name: Maggie Residence --Existing ;Cate. 10/1/1999 Address= 55-515 Riviera ; La Qulnta, Ca ',Building Permit No Designer= Robert A. Pitchford, Design & Drafting ;Checked by / Date Documentation: BREEZE ATR CONDITIONING ---------------------------------------------------7----------------------- ;COMPLY 24 User 3665 GENERAL INFORMATION compliance Method: COMPLY 24 version 5.10 Climate Zone: 15 Conditioned Floor Area: 3882 sqft Building Type: Exist+Add Occupancy Type= Single Fam Det Building Front Orientation: 70 deg (E) Number of Dwelling Units: 1 Floor ConstructionType: Slab on Grade BUILDING SHELL INSULATION Component U ------------------------------ -Value Location/Comments ------------------------------------ R-19 Wall (W.19.2x6.16) 0.065 Existing Residence Solid Wood Door 0.387 Existing Residence R-21 Wall (W.21.2x6.16) 0.059 Existing Residence R-11 Wall (W.11.2x4.16) 0.098 Existing Residence R-19 Roof (R.19.2x8.16) 0.051 Existing Residence Slab Perimeter w/R-0.0 0.900 Existing Residence Slab Perimeter w/R-0.0 0.720 Existing Residence FENESTRATION Shading Devices Frame orient. Area U -Val Type --------- ------ ----- ------ Interior --------------- Exterior --------------- OH SF Type -- -- ----- Front (E) 19.6 1.19 Single Std Drape none Y N Metal Front (E) 80.0 1.25 Single Std Drape Standard Bug Scr N N Metal Front (E) 25.0 1.28 Single Std Drape Standard Bug Scr N N Metal Lett (S) 25.0 0.72 Double Std Drape none N N Metal Left (S) 64.0 0.77 Double Std Drape Standard Bug Scr N N Metal Left (S) 25.0 1.19 Single Std Drape none N N Metal Lent (S) 80.0 1.25 Single Std Drape Standard Bug Sc;r N N Metal Lett (S) 80.0 1.28 Single Std Drape Standard Bug Scr N N fetal Back (W) 53.0 0.72 Double Std Drape none N N Metal Back (W) 40.0 0.77 Double Std Drape Standard Bug Scr N N Metal Back (W) 10.0 1.19 Single Std Drape none N N Metal Back (W) 24.0 1.28 Single Std Drape Standard Bug Scr N N Metal Right tN) 25.0 1.19 Single Std Drape none N N Metal Right (N) 7.5 1.28 Single Std Drape Standard Bug Scr N N Metal Skylight 15.2 0.80 Double none none N N Metal THERMAL MASS Area 'Thick Type. covering ----------------------------- Of) (in) Location/Description ----- ----- ------------------------------ Concrete, Heavyweight Exposed 899 3.50 Slab on Grade • Concrete, Heavyweight Covered 2983 3.50 Slab on Grade CERTIFICATE OF COMPLIANCE - Residential (part 2 of 2) CF -1R page 4 oi- 24 --------------------------------------------------------------------------- Pro,ject Name: Maggio Residence --Existing ;Late: 10/1/1999 • Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ------------------------------------------------- MVAC SYSTEMS Minimum DistribType Duct TStat System Type Efficiency and Location RVal Type Location/Comments ------------------------------------- ---- ------ ----------------------- Furnace 0.1£30 AFUE Ducts in Attic 4.2 SetBck Existing/Addition Lone SpltAirCond10.000 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution 'Type Type Sys Factor (gal) R-Va1 ------------------------------------------------ ---------- ----- ----- Std Gas 50 gal or Less Standard StorGas 2 0.53 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light ----------------------- ----------- ---- ----- ----- ----- ----- Std Gas 50 gal or Less DomesticHW 0.180 40000 0.040 0.0 0 SPECIAL FEATURES/REMARKS COMPLIANCE STATEMENT This Certzticate of Compliance lists the Building Treatures and performance specifications needed to comply with Title 24, Parts 1 &-6 oi= the Califor- nia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual. with overall design responsibility. When this certificate of compliance is submitted -for a single Building plan to be built in multiple orientations, any shading -feature that is varied is indicated in the Special Features/Remarks section DESIGNER or OWNER (Per Business & Professions Code), Robert A. Pitchford, Design & Drafting 41-625 Eclectic, Suite A-2 Palm Desert260 � i 60) 34 , 2856 l ENFORCEMENT AGENCY Name= i�tle: Agency: Telephone= 9 DOCUMENTATION AUTHOR Tim Scott BREEZE AIR CONDITIONING 75-145 ST CHARLES PLACE PALM DESERT, CA 92260 (619)j346-0855 si nature ) 1 rate j (signature/stamp) ( date ) MANDATORY MEASURES CHECKLIST ( part 1 of 2) MF -1R page 5 o'l 24 --------------------------------------------------------------------------- Project Name: Maggio Residence --Existing ;Date: 10%1/1999 Documentation: BREEZE AIR CONDITION'I'NG ;COMPLY 24 User 3665 --------------------------------------------------------------------------- NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this ChecKllst is incorporated into the permit documents, the features noted shall be considered by all parties as binding [nlnimum component peri-ormance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES En-forceffient o Sec. 150(a): Minimum R-19 ceiling insulation. * o Sec. 150(b): Loose fill insulation manufacturers labeled R -Value. o Sec. 150(c): Minimum R-13 wall insulation in framed wails idoes not apply to exterior mass walls). * o Sec. 150id): Minimum R-13 raised -floor insulation in framed 'i-loors; Minimum R-8 in concrete raised floors. * • o Sec. 150(1): Slab edge insulation - water absorption rate no,j greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 118: Insulation specified or installed meets California Energy Commission quality standards. Indicate Type & torm. o Sec. 116-117: Fenestration Products, Ext Doors & In-fil/Ext-ii Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label w/certified U -Value c.,Exterior doors and windows weatherstripped, ail joints and penetrations caulked and sealed. o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. o Sec. 150((): Special infiltration barrier installed to' comply with Sec. 151 meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2.. No continuous burning gas pilots allowed. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13: HVAC equipment, water heaters, showerhieads and faucets certified by the Commission. o Sec. 150(1): Setback thermostat on all applicable heating systems. o Sec. -150(j): Pipe and Tank insulation 1. indirect hot water tanks (eg unf=ired storage tanks or backup -solar hot water tanks) have insulation biamket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 meet of pipes closest to water heater tank., non -recirculation systems, insulated (R-4 or greater 3. Ali buried or exposed piping insulated in recircu_ation sections of hot water system. 4. Cooling system piping below 55 F insulated. 5. Piping insulated between heating source and indirect hot water tank. o Sec. 150(m) Ducts and Fans • 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. o Sec. 114=Pool and Spa Heating Systems and Equipment I. System is certified with Z8% thermal efficiency, an -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light. (Exception= Non -electrical cooking appliance with pilot < 150 Btuh) LIGHTING MEASURES o Sec..150(k): Lighting - 40 lumens/watt or greater for 411 general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures 1C (insulation cover) approved. MANDATORY MEASURES CHECKLIST ( part 2 of 2) ---------------------------------------------------------------------------- MF -IR page 6 of 24 project Name: Maggio Residence --Existing ;Cate: 10/1/1999 • Documentation: BREEZE ATR CONDITIONING--______�__----�COMPLY_24 ---------------------------------------- User 3665 ---------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13: HVAC equipment, water heaters, showerhieads and faucets certified by the Commission. o Sec. 150(1): Setback thermostat on all applicable heating systems. o Sec. -150(j): Pipe and Tank insulation 1. indirect hot water tanks (eg unf=ired storage tanks or backup -solar hot water tanks) have insulation biamket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 meet of pipes closest to water heater tank., non -recirculation systems, insulated (R-4 or greater 3. Ali buried or exposed piping insulated in recircu_ation sections of hot water system. 4. Cooling system piping below 55 F insulated. 5. Piping insulated between heating source and indirect hot water tank. o Sec. 150(m) Ducts and Fans • 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. o Sec. 114=Pool and Spa Heating Systems and Equipment I. System is certified with Z8% thermal efficiency, an -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light. (Exception= Non -electrical cooking appliance with pilot < 150 Btuh) LIGHTING MEASURES o Sec..150(k): Lighting - 40 lumens/watt or greater for 411 general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures 1C (insulation cover) approved. POINT SYSTEM SUMMARY --------------------------------------------------- P -2R page . 7 of 24 =------ Projec•t Name: Maggio Residence --Existing -------- --------- ;Date: 10/1/1999 • Documentation: BREEZE Alk CONDITIONING ----------------------------------------- ----------------;COMPLY-24-User-3665 BUILDING DATA ------------- Conditioned Floor Area 3882 sgft Number of Stor:ies 1 Occupancy Type Single Fam Det SCORE CARD Measure Points 1. Roof insulation 0.0512 '(U -Value) -5 .2. Wall Insulation 0.0663 (U -Value) 3. Raised Floor Insulation 0.0000 CAaluek 3a. Controlled Vent Crawlspace 0.0 (R -Value) i 0 4. Slab Edge Insulation 0,7588 (9-2 factor i )-; 5. Infiltration Standard 0 ,6. Glass Heat Loss 1.09 14.8% -6 Sum -i-6 -13 7. Fenestration Heat Gain SC Orientation Area ,oGlass' Open Eff o SE.R • _- - - North 32.5 0.8 x 0.89 = 0.7" 0.78 2 East 124.6 3.2 x 0.84 = 2.7 0.78 -2 South 274.0 7.1 x 0.,76 = 5.4 0.83. '79 West 127.0 3.3 x 0.65 = 2.1 0.89 -1 Skylight 15.2 0.4 x 0.58 = 0.2 8. interior 'Thermal Mass 2.45 1 9. Exterior Wah' Mass 0.00 0 Sum 7-9 '-10 10. Heating System 0 Zonal Control: No 11.,Co6i ny System 0 12. Water Heating = -3 Point Totai: -26 Point Goal= 0 POINT SYSTEM SUMMARY - Existing,Building P -2H page 8 oi- 24 ------ --------------------------------------------------------------------- Project Name: Maggio Residence --Existing, ;Date: 10/1/1999 •Documentation: BREEZE Alk CONDITIONING ;COMPLY 24 User 3665 ------------------------- --------------------------------------------------- BUILDING DATA Conditioned Floor Area. 3882 sgft Number of Stories 1., Occupancy Type Single Fam Det SCORE CARD Measure Points 1. Hooi, insulation , 0 .0512 (U -Value) -5 2. Wall Insulation 0.066:3 (U -Value) -2 3. Raised Floor Insulation 0.0000 (U -Value) ,3a. Controlled Vent Crawlspace 0.0 (R -Value) ;-, 0 i 4. Slab Edge Insulation 0.7588 if2 factor)_; 5. ini-iitration Standard 0 6. Glass Heat Loss 1.09 14.8% -6 Sum 1-6 -13 7. Fenestration Heat Gain SC • Orientation Area %Glass Open Ef•1 o SEH -- - - North 32.5 0.8 x 0.89 = 0.7 0.78 2 East 124.6 3.2 x 0.84 = 2.7 0.78 -2 South 274.0 7.1 x 0.76 = 5.4 0.83 -9 West 127 .0 3.3 x 0.65 = 2.1 0 .89 -1 Skylight 15.'2 0.4 x 0.58 = 0.2 1.00 -1 8. Interior Thermal Mass 2.45 9. Exterior Wall Mass 0.00 10. Heating System Zonal Control: No 11. Cooiing System 12. Water Heating = PC.int Total: Point Goal.- 0 oal: u Sum 7=9 COMPUTER METHOD SUMMARY (part 1 -of 3) C -2R page 9 of 24 -------------------------------------------------------------------------- - Project Name: Maggio Residence --Existing ;Date:.10/1/1999 •Documentation= BREEZE ATR CONDITIONING ;COMPLY 24 User 3665 -------------------------------- ------------------------ =------------------ POINT SYSTEM COMPLIANCE SUMMARY Proposed Design Point Score Budget Compliance Point Goal GENERAL INFORMATION Compliance Method: Climate Zone: Conditioned Floor Area: Building Type= Occupancy Type: Building Front Orientation: Number of Dwelling Units: Number of Stories Floor Construction Type= Total Conditioned Volume: Conditioned Footprint Area: Ground Floor Area: -26 Points *BUILDING DOES NOT COMPLY* 0 Points COMPLY 24 version 5.10 15 3882 sqf t Exist+Add Single Fam'Det 70 deg (E) 1 1 Siab.on Grade 32997 tuft 3882 sgtt 3882 sgft BUILDING ZONE INFORMATION Floor # of Vent Zone Name Area. Volume Units Zone Type TStat Type Hgt Area ----------------------- ----- --------------------------------- --- ---- Existing/Addition Zone 3882 32997 1.00 Conditioned Setback 2 n/a OPAQUE SURFACES Act Solar Type Area U-Vai Azm Tilt Gains Form 3 Ref=erence Location/Comments ZONE NAME = Existing/Addition Zone Wall 266 0.065 70 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Door 27 0.387 70 90 Yes Solid Wood Door Existing Residence Wall 671 0.065 160 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 358 0.065 250 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 840 0.065 340 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 20 0.059 70 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 51 0.059 160 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 119 0.059 250 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wail 56 0.098 160 90 Yes R-11 Wall (W.11.2x4.16) Existing Residence Wall 44 0.098 250 90 Yes R-11 Wall (W.11.2x4.16) Existing Residence Roof 3867 0.051 70 22 Yes R-19 Roof (8.19.2x8.16) Existing Residence F2 0 COMPUTER METHOD SUMMARY --- _ ------------------------------------------------------ ( part 2 of 3) U -2R page 10 of 24 Project Name: Maggio Residence --Existing ;Date: 10/1/1999 • Documentation: ------------------------------------------------------------------ BREEZE ATR CONDITIONING ;COMPLY 24 User 0665 ' ------- PERIMETER LOSSES F2 Insulation Type --------- Length ------ Factor ------ R -Val ----- Depth Location/Comments ----- ----------------------- ZONE NAME = Existing/Addition Lone Exposed 90.0 0.90 0.0 0 in Existing Residence Covered 327.0 0.72 0.0 0 in Existing (Residence F ENES TRA'T' ION SURFACES SC Act Giass # -- Type ------------- Area Frame Div U -Val Azm 'Tilt Only Location/Comments ' ZONE NAME = ----- ----- Existing/Addition --- Lone ----- --- ---- ----- --------------------- 1 Wdw Front (L) 25.0 Metal No 1.28 70 90 1.00 Existing Residence 2 Wdw Front (E) 9.8 .Metal No 1.19 70 90 1.00 Existing Residence 3 Wdw Front (E) 9.8 Metal No 1.19 70 90 1.00 Existing Residence 4 Wdw Front (E) 80.0 Metal No 1.25 70 90 1.00 Existing Residence 5 Wdw Lett (S) 32.0 fetal No 1.28 .160 90 1.00 Existing Residence 6 Wdw Left (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 7 Wdw Le -ht (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 8 Wdw Lent (S) 32.0 Metal No 1.28 160 90 .1.00 Existing Residence. 9 Wdw Left (S) 80.0 Metal No 1.25 160 90 1.00 Existing Residence 10 Wdw Lent (S) 25.0 Metal No 1.19 160 90 .1.00 Existing Residence • 11 Wdw Back (W) 24.0 Metal No 1.28 250 90 1.00 Existing Residence 12 Wdw Back. (W) 10.0 Metal No 1.19 250 90 1.00 Existing Residence 13 Wdw Right (N) .7.5 Metal No 1.28 340 90 1.00 Existing Residence 14 Wdw Right (N) 25.0 Metal No ,1.19 340 90 1.00 Existing Residence 15 Wdw Left (S) 25.0 Metal No 0.72 160 90 0.65 Existing Residence 16 Wdw Lent (S) 64.0 Metal No 0.77 160 90 0.65 Existing Residence 17 Wdw Back (W) 28.0 Metal No 0.72 250 .90 0.65 Existing Residence 18 Wdw Back (W) 25.0 Metai No 0.72 250 90 0.65 Existing Residence 19 Wdw BacK (W) 40.0 Metal No 0.77 250 90 0.65 Existing Residence 20 Sky Front (E) 15.2 Metal. No 0.80 70 0 0.65 Existing Residence INTERIOR & EXTERIOR SHADING # -- 'Type ---- Interior ----------------------- Shade Type Sc Exterior Shade Type SC 1 Wdw Std Drape ---- 0.78 ------------------------ Standard Bug Screen ---- 0.87 2 Wdw Std Drape 0.78 None 1.00 3 Wdw Std Drape 0.78 None i.00 4 Wdw Std Drape 0.78 Standard Bug Screen 0.87 5 Wdw Std Drape 0.78 Standard Bug Screen 0.87 6 Wdw Std Drape 0.78 Standard Bug Screen 0.87 7,Wdw Std Drape 0.78 Standard Bug Screen 0.87 S Wdw Std,Drape 0.78 Standard Bug Screen 0.87 9 Wdw Std Drape 0.78 Standard Bug Screen 0.87 .10 Wdw Std Drape 0.78 None 1.00 •11 Wdw Std Drape 0.78 Standard BugScreen 0.87 12 Wdw Std Drape 0.78 None 1.00 13 Wdw Std Drape 0.78 Standard Bug Screen 0.87 14 Wdw Std Drape 0.78 None 1.00 15 Wdw Std Drape 0.78- None 1;00 .16 Wdw Std Drape 0.78 Standard Bug Screen 0.87 17, Wdw Std Drape 0.78 None 1.00 18 Wdw Std Drape 0.78. None i.00 OVERHANGS/SIDE FINS --Window-_ -----Overhang------ ---Lent Fin--- ---Right Fin-- ## Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht -- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2 Wdw, , 6.5 1.5 4.0 0.1 4.0 4.0 3 Wdw 6.5 1.5 4.0 0.1 4.0 4.0 THERMAL MASS Area Thick Heat Inside Location Type (sf) (in) Cap Cond Form 3 Re'f'erence R-Vai . Comments ------------- ---- ----- ----- --------------------------- ------ -------- LUNE NAME = Existing/Addition Zone Exposed Slab 899 3.50 28 0.98 n/a 0 Covered Slab 2983 3.50 28 0.98 n/a 2 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency and Location RVal Type Location/Comments ------------------------------------- ---- ------ ----------------------- Furnace 0.180 AFUE Ducts in Attic 4.2 SetBck Existing/Addition Zone SpitAirCond10.000 SEER Ducts in Attic 4.2 SetBck • Water No. - 'rank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val ------------------------------------------------ --- ------ ----- ----- Std Gas 50 gal or Less Standard StorGas 2 0.53 50.0 12.0 AF UE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light ----------------------- ----------- ---- ----- ----- ----- ----- Std Gas 50 gal or Less UomesticHW 0.•'7.80 40000 0.040 0.0 0 SPECIAL FEATURES/REMARKS • COMPUTER METHOD SUMMARY (part 3 of 3 ) ------------- -------------------------------------------------------------- C -2R page 11 of 24 Project Name= Maggio Residence --Existing ;Late: •i 10/1/1999 •Documentation: BREEZE -ATR CONDITIONING -------------------------------------- ;COMPLY ------- 24 User 3665 ---_---- ----- OVERHANGS/SIDE FINS --Window-_ -----Overhang------ ---Lent Fin--- ---Right Fin-- ## Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht -- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2 Wdw, , 6.5 1.5 4.0 0.1 4.0 4.0 3 Wdw 6.5 1.5 4.0 0.1 4.0 4.0 THERMAL MASS Area Thick Heat Inside Location Type (sf) (in) Cap Cond Form 3 Re'f'erence R-Vai . Comments ------------- ---- ----- ----- --------------------------- ------ -------- LUNE NAME = Existing/Addition Zone Exposed Slab 899 3.50 28 0.98 n/a 0 Covered Slab 2983 3.50 28 0.98 n/a 2 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency and Location RVal Type Location/Comments ------------------------------------- ---- ------ ----------------------- Furnace 0.180 AFUE Ducts in Attic 4.2 SetBck Existing/Addition Zone SpitAirCond10.000 SEER Ducts in Attic 4.2 SetBck • Water No. - 'rank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val ------------------------------------------------ --- ------ ----- ----- Std Gas 50 gal or Less Standard StorGas 2 0.53 50.0 12.0 AF UE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light ----------------------- ----------- ---- ----- ----- ----- ----- Std Gas 50 gal or Less UomesticHW 0.•'7.80 40000 0.040 0.0 0 SPECIAL FEATURES/REMARKS • COMPUTER METHOD SUMMARY -Existing Building part 1 & 3)C -2R page 12 of 24 ------------------------------=-------------------------------------------- Project Name: Maggio Residence --Existing ;Cate:. 10%1/1999 i • Documentation: BREEZE ATH CONDITIONING WOMPLY-24-User-3665 POINT SYSTEM COMPLIANCE SUMMARY Proposed Design Point Score Budget Compliance Point Goal GENERAL INFORMATION Compliance Method: Climate Zone: Conditioned Floor Area: Building Type: Occupancy Type: Building Front orientation: Number of Dwelling Units: Number of Stories: Floor Construction Type: Total Conditioned Volume:. Conditioned Footprint Area: Ground Floor Area: -26 Paints *BUILDING DOES NOT COMPLY* U Points COMPLY 24 version 5.10 15 3882 sqf t Exist+Add Single Fam Det 70 deg (E) "1 1 Slab on Grade 32997 cult 3882 sgft 3882 sqf t BUILDING ZONE INFORMATION Floor # of Vent Zone Name Area Volume Units Zone Type TStat Type Hgt Area ----------------------- ----- ------ -------------------------- --- ---- Existing/Addition "Zone 3882 32997 1:00 Conditioned ;setback 2 n/a OPAQUE SURFACES Act I Solar (ype Area U-Vai Azm Tilt Gains Form 3 Reference Location/Comments ZONE NAME = Existing/Addition Zone Wall 266 0.065 70 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Door 27 0.387 70 90 Yes Solid Wood Door Existing Residence Wall 671 0.065 160 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 358 0.065 250 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 840 0.065 340 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 20 0.059 70 90 Yes R-21 Wall CW.21.2 % .16) Existing Residence will 51 0.059 160 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 119 0.059 250 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 56 0.098 160 90 Yes R-11 Wall (W.11.04.16) Existing Residence Wall 44 0.098 250 90 Yes R-11 Wall (W.11.2x4.16) Existing Residence Roof 3867 0.051 70 22 Yes R-19 Roof (R.19.2xR.16) Existing Residence 0 COMPUTER METHOD SUMMARY -Existing Building ( part 2 of O )C -2R- ' page 13 of 24 --------------------------------------------------------------------------- Project Name= Maggio Residence --Existing ;Gate= 10/1/1999 Documentation: BREEZE ATR CONDITIONING • _;COMPLY 24 User 3665 ------------------------------------------------------ _--_--------- PERIMEI"ER LOSSES F2 insulation Type --------- Length Factor R -Val Depth Location/Comments ZONE NAME = ______ Existing/Addition ______ Lone ----- ----- _______________________ Exposed 90.0 0.90 0.0 .0 in Existing Residence Covered 327.0 0.72 0.0 0 in Existing Residence FENESTRATION SURFACES SC Act Glass # -- Type ------------- ----- Area Frame ----- Div --- U -Val ----- Azm Tilt Only Location/Comments ZONE NAME = Existing/Addition Zone --- ---- ----- --------------------- 1 Wdw Front (E) 25.0 Metal No 1.28 70 90 1.00 Existing Residence 2 Wdw Front (E) 9.8 Metal No 1.19 70 90 1.00 Existing Residence 3 Wdw Front (E) 9.8 Metal No 1.19 70 90 1.00 Existing Residence 4 Wdw Front (E) 80.0 Metal No 1.25 70 90 1.00 Existing Residence 5 Wdw Left (S) 32.0 Metal No 1.28 160 90 1.00 Existing Residence 6 Wdw Lent (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 7 Wdw Left (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 8 Wdw Lent (S) 32.0 Metal No 1.28 160 90 1.00 Existing Residence 9 Wdw Left (S) 80.0 Metal No 1.25 160 90 1.00 Existing Residence 10 Wdw Lent (S) 25.0 Metal No 1.19 160 90 1.00 Existing Residence • 11 Wdw Back (W) 24.0 Metal No 1.28 250 90 1.00 Existing Residence 12 Wdw Back (W) 10.0 Metal No 1.19 250 90 1.00 Existing Residence 13 Wdw Right (N) 7.5 Metal No 1.28 340 90 1.00 Existing Residence 14 Wdw Right (N) 25.0 Metal No 1.19 340 90 1.00 Existing Residence 15 Wdw Left (S) 25.0 Metal No 0.72 160 90 0.65 Existing Residence 16 Wdw Lent (S) 64.0 Metal No 0.77 160 90 0.65 Existing Residence ? Wdw Back tW) 28.0 Metal No 0.72 250 90 0.65 Existing Residence 18 Wdw Back (W) 25.0 Metal No 0.72 250 90 0.65 Existing Residence 19 Wdw Back (W) 40.0 Metal No 0.77 250 90 0.65 Existing Residence 20 Sky Front (E) 15.2 Metal No 0.80 70 U 0.65 Existing Residence INTERIOR & EXTERIOR SHADING # Type Interior Shade 'Type SC Exterior Shade Type SC 1 Wdw Std Drape 0.78 Standard Bug Screen 0.87 2 Wdw Std Drape 0.78 None 1.00 3 Wdw Std Drape 0.78 None 1.00 4 Wdw Std Drape 0.78 Standard Bug Screen 0.87 5 Wdw Std Drape 0.78 Standard Bug Screen 0.87 6 Wdw Std Drape 0.78 Standard Bug Screen 0.87 7 Wdw Std Drape 0.78 Standard Bug Screen 0.87 8 Wdw Std Drape 0.78 Standard Bug Screen 0.87 9 Wdw Std Drape 0.78 Standard Bug Screen 0.87 10 Wdw Std Drape 0.78 None 1.00 .11 Wdw Std Drape 0.78 Standard Bug Screen 0.87 12 Wdw Std Drape 0.78 None 1.00 13 Wdw Std Drape 0.78 Standard Bug Screen 0:87 14 Wdw Std Drape 0.78 None 1.00 15 Wdw Sial Drape 0.78 None 1.00 16 Wdw Std Drape 0.78 Standard Bug Screen 0.87 17 Wdw Std Drape 0.78 none 1.00 18 Wdw Std Drape 0.78 None 1.0o SPECIAL FEATURES/REMARKS 0 COMPUTER METHOD SUMMARY -Existing Building (part 3 of 3)C -2R page 14 of 24 ----------- --------------------------------------------------------------- Project Name: Maggio Residence --Existing Nate:10/1/1999 ' Documentation: BREEZE AIR CONDITIONING --------------- ;COMPLY-24User3665' -- OVERHANGS/SIDE F -INS __Window-- ----Overhang---------Left Fin?-- ---Right_.Fin-- # Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht 2 Wdw 6.5 1.5 4.0 0.1 .4.o 4..o 3 Wdw 6-.5 1.5 4.0 0.1 4 .0 4.0 THERMAL MASS Area Thick Heat Inside Location Type l S j (in) Cap Cond Form 3 Reference R-Vai . Comments ------------- ----- ----- ----- --------------------------- ZONE NAME = Existing/Addition Zone ------ -------- Exposed Slag 899 0.50 28 0.98 n/a 0 Covered Slam 2983 3.50 28 0.98 n/a 2 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency and Location RVal Type ------------------------------------- ---- ------ Location/Comments Furnace 0.780 AFUE Ducts in Attic 4.2 SetBck ----------------------- Existing/Addition Zone SpltAirCond10.000 SEER .Ducts in Attic 4.2 SetBck Water No. 'lank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val Std Gas 50 gal or Less Standard StorGas 2 -0.53 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0 SPECIAL FEATURES/REMARKS 0 COMPONENT DESCRIPTION ----------------------------- ------------------------------- i i i i i Sketch Of COT1StrUCtion Assembly Assembly Name: R-11 Wall (W . 11 .2x4.16 ) Assembly 'T'ype: Wall Assembly Tilt' 90 deg ( Vertical ) Framing Material: Woad Framing Spacing-'_ O.C. Framing Percent: 15..(.) Absorptivity: 0./0 Roughness: Stucco, Wood Shingles ASSEMBLY U -VALUE PROPOSED CONSTRUCTION --------------------------------------------------------------------------- ASSEMBLY ENV -3 page 1,5 of 24 Th Project Name; Maggio Residence--Existirig ;Date: 10/1/1999 • Documentation: BREEZE ---------------------------------------------------------------------------- AIR' CONDITIONING ;COMPLY 24 User 3665 COMPONENT DESCRIPTION ----------------------------- ------------------------------- i i i i i Sketch Of COT1StrUCtion Assembly Assembly Name: R-11 Wall (W . 11 .2x4.16 ) Assembly 'T'ype: Wall Assembly Tilt' 90 deg ( Vertical ) Framing Material: Woad Framing Spacing-'_ O.C. Framing Percent: 15..(.) Absorptivity: 0./0 Roughness: Stucco, Wood Shingles ASSEMBLY U -VALUE Th R -Value Construction Components --------------------------------------------------------------------------- Fr (Ira ). Cavity name Outside Air Film 1. Stucco 0 .81 5 0.17 O. 1 2. Membrane, Vapor -Permeable Felt 0.03.0 0.06 0.06 3. insulation, Minerai Fiber, R-11 * 3.500 .11.00 3.46 4. Gypsum or Plaster Board 0.500. 0.45 0.45 5. 6. • 8. ti. i.riside Air Film --------------------------------------------------------------------------- 0.68 0.68 Unadjusted R -Values 12.53 5.00 ADJUS'T'MENT FOR FRAMING (1 /12.53) x (0.85) + (1, / 5.00) x (0.15) Weight e 12.3 lb/sq-ft 'cleat Capacity: 2.87 1 0.098 'TOTAL U> VALUE = TOTAL R -VALUE = 0.098, 10.22 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 16 PY 24 ---------------------------------------- ---------- ----------------------- Project Name:,Maggio Residence --Existing :Date; 10/1/1999 (documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User :665 • _- ------------- ---------------------------------------------------------- COMPONENT DESCRIPTION Assembly Name: R-19 Wali ( W . 19 .2x6.16 ) ------------------------------- Assembly Type- Wall• Assembly Tiit: 90 deg (Verticai). III 0 Sketch of Construction Assembly ASSEMBLY U -VALUE Framing Material: Woad Framing Spacing: O.C. Framing Percent; 15.07 % Absorptivity: 0.70 Roughness: Stucco, Wood Shingles ADJUSTMENT FOR FRAMING W /19.33) x (0.85) + Q / 6.98) x (0.15) Weight; Heat Capacity= 13.2 ltd/sgft 3.23 0.065 T 0TAL U -VALUE = 0. 065' TOTAL R -VALUE = 15:28 Th R -Value Construction Components FT � in) Cavity Frame Outside Air Film 0.17 0.17 1. Stucco 0.875 0.17 0.17 Z. Membrane, Vapor -Permeable Felt 0.O1O 0.06 0.06 3. Insulation, Mineral Fiber, R-17.8 * 5.500 17:80 5.45 4. Gypsum or Plaster Hoard O.500 0.45 0.45 5. 8. 9. inside Air Flim 0.68 U..68 unadjusted R -Values 19.33 6.98 ADJUSTMENT FOR FRAMING W /19.33) x (0.85) + Q / 6.98) x (0.15) Weight; Heat Capacity= 13.2 ltd/sgft 3.23 0.065 T 0TAL U -VALUE = 0. 065' TOTAL R -VALUE = 15:28 COMPONENT DESCRIPTION ------------=------------------- ------------------------------- � t Sketch ot Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-21 Wall (W .21 .2x6.16 ) Assembly Type: Wall Assembly Tilt: 90 dog (Vertical] Framing Material: Woad Framing Spacing: O.C. Framing Percent: 15.0 `a Absorptivity: 0.70 Roughness: Stucco, Wood Shingles PROPOSED CONSTRUCTION ------------------------------------------------------------------ ASSEMBLY ENV -3 page 17 of 24 Cavity Projec;t Name: Maggio Residence --Existing ;Date= 10/1/1999 • Documentation: BREEZE ATR CONDITIONING ;COMPLY 24 User 0665 COMPONENT DESCRIPTION ------------=------------------- ------------------------------- � t Sketch ot Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-21 Wall (W .21 .2x6.16 ) Assembly Type: Wall Assembly Tilt: 90 dog (Vertical] Framing Material: Woad Framing Spacing: O.C. Framing Percent: 15.0 `a Absorptivity: 0.70 Roughness: Stucco, Wood Shingles ADJUSTMENT FOR FRAMING (1 /22.53) .'x (0.85) + ( 1 / 6.98) x (0.15) - 0.059 TOTAL U -VALUE = 0.059 Weight: Heat Capacity: 0 13.2 lb/sq t 3.23 TOTAL - R -VALUE Th R -Value . Construction Components Fr (in) Cavity Frame Outside Air Film 0.17 0.17 1. Stucco 0.875 0.1 0.17 2. Membrane, Vapor -Permeable Felt . 0.010 0.06 0.0.6 3. Insulation, Mineral Fiber, R-21 * 5.500 21:00 5.45 4. Gypsum or Plaster Hoard 0.500 0.45 0.45 5. 6. 7. ,8 y Inside Air Film --------------------------------------------------------------------------- 0.68 0.68' Unadjusted R -Values 22.5:3 6.98 ADJUSTMENT FOR FRAMING (1 /22.53) .'x (0.85) + ( 1 / 6.98) x (0.15) - 0.059 TOTAL U -VALUE = 0.059 Weight: Heat Capacity: 0 13.2 lb/sq t 3.23 TOTAL - R -VALUE COMPONENT DESCRIPTION ------------------------------- ----------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-19 Roof (R.19.2x8.16) Assembly 'T'ype: Room Assembly Tilt: 22 deg (Tilted UP) Framing Material: Woad Framing Spacing: _' O.C. Framing Percent: 10.09 % Absorptivity: 0./0 Roughness: concrete, Asph. Shingles PROPOSED CONSTRUCTION --------------------------------------------------------------------------- ASSEMBLY ENV -3 page 18 of 24 Cavity Project Name: Maggio..Residence--Existing Outside Air Film ;Date: 10/1/1999 • Documentation BREEZE ---------------------- ALR CONDI'T'IONING --_ --------- ---------- -- ; COMPLY -24 -User -3665 COMPONENT DESCRIPTION ------------------------------- ----------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-19 Roof (R.19.2x8.16) Assembly 'T'ype: Room Assembly Tilt: 22 deg (Tilted UP) Framing Material: Woad Framing Spacing: _' O.C. Framing Percent: 10.09 % Absorptivity: 0./0 Roughness: concrete, Asph. Shingles ADJUSTMENT FOR FRAMING (1 /22.11) x (0.90) + (1 / 9.53) x (0.10) Weight: ' . Heat Capacity 171 7.4 lb/ygft 2.28 0.051 TOTAL U -VALUE = 0.051 TOTAL R -VALUE = 19.53 Th R -Value Construction Components • F'r. (in) Cavity Frame Outside Air Film 0.1/ 0.1/' 1. Roofing, Asphalt Shingles 0.250 0.44 0.44 2'. Membrane, Vapor -Permeable Felt 0.010.. 0.06 0.06 3. Plywood 0.500 0.62 0.62 4. Air Space * 1.2bO 0./5 1.24 5. Insulation, Mineral Fiber, R-19 * 6.000 19.00 5.94 6. Gypsum or Plaster :Hoard 0.590 0.45 0.45 /. 8. 9. Inside Air Film ----------------------- -.---------------------- "0.61 0.61 Unadjusted ----------------------------- H -Values 22.11 9.53 ADJUSTMENT FOR FRAMING (1 /22.11) x (0.90) + (1 / 9.53) x (0.10) Weight: ' . Heat Capacity 171 7.4 lb/ygft 2.28 0.051 TOTAL U -VALUE = 0.051 TOTAL R -VALUE = 19.53 • 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 19 of 24 ------------------------------------------------------------------------ --- Projeci, Name. Maggio residence --Existing ;Date: 10/1/1999 i Documentation: BREEZE ATR CONDITIONING ;COMPLY 24 User 3665 COMPONENT DESCRIPTION Assembly Name: Carpeted Slab On Gracie ------------------------------- Assembly Type: Floor Assembly Tilt: 180 deg (Horizontal.Flour) Framing Material: None Framing Spacing: O.C. Framing Percent: 0.0 % Absorptivity: 0,00 ------------------------------- Sketch of Construction Assembly Roughness: Concrete, Asph. Shingles ASSEMBLY U -VALUE ADJUSTMENT FOR FRAMING (1 / 7.45) x (1.00) + 7.45) x (0.00) Weight: Heat Capacity: 210.9 lb/syft 42.19 0.134 TOTAL U -VALUE* _ TOTAL R -VALUE _ 0.134 7.45 Th R -Value Construction -Components --------------------------------------------------------------------------- Fr lirnj Cavity Frame Outside Air Film U.17 U.17 1. Earth 24.000 4.00 4.00 2. Concrete, 140 lb, Not Dried 3.500 0.28 0.28 3. Flooring, Carpet and Fibrous Pad 0.250 2.08 2.08 4. 5. 6. 7, E3 . 9. inside Air Film -----------------------------.. ---------------.-------- 0.92 0,92 Unadjusted _ _-------------------- R -Values 7.45 7.45 ADJUSTMENT FOR FRAMING (1 / 7.45) x (1.00) + 7.45) x (0.00) Weight: Heat Capacity: 210.9 lb/syft 42.19 0.134 TOTAL U -VALUE* _ TOTAL R -VALUE _ 0.134 7.45 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 20 of 24 --------------------------------------------------------------------------- Project Name: Maggio Residence --Existing ;Date: 10/1/1999 Documentation: BREEZE ATR CONDITIONING ;COMPLY 24 User 3665 "----------------------------------------------- -------------------------- COMPONENT DESCRIPTION Assembly Name= Exposed Slab On Grade Assembly Type= Floor- i, Assembly Tilt: 180 deg (Horizontal Floor) Framing Material Nome Framing Spacing= �" O.C. Framing Percent: 0.0 Absorptivity: U.00 ----------------------------- Sketct*i of Construction Assembly Roughness: Concrete, Asph. Shingles ASSEMBLY U -VALUE ADiUSTMEN'i` FUR FRAMING x (1.00) + ll / 5,3.7) x (0.00)- Weight: :Heat Capacity. 210.8 lb✓syft 42.17 0.186 TOTAL U -VALUE = 0.186 TOTAL R -VALUE = 5.37 Th R -Value. Construction Components Fr (ira) Cavity Frame Outside.Air Film 0.17 0.17 1. Earth 24.000 4.00 . 4.00 2. Concrete, 140 lb, Not Dried 3.5080 0.28 0.28 3 4. 5. 6. 7. 8. 9, Inside Air Film -------------------------------------7------------------------------------- 0.92 0,92 Unadjusted R -Values 5,3i` 5.37 ADiUSTMEN'i` FUR FRAMING x (1.00) + ll / 5,3.7) x (0.00)- Weight: :Heat Capacity. 210.8 lb✓syft 42.17 0.186 TOTAL U -VALUE = 0.186 TOTAL R -VALUE = 5.37 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 21 of, 24 ------------------------------------------------------------------------- Project Mame: Maggio Residence --Existing ;Daae: 10/1/1999 Documentation= BREEZE AIR CONDI'iIONING ;COMPLY 24 User 3665 • -------------------------•--------------- -------------------- ------------ COMPONENT DESCRIPTION Assembly Name: Solid Wood :Door Assembly Type: Door Assembly Tilt= 90 deg l Vertical j Framing Material= None Framing Spacing= O.C. Framing Percent: 0.0 % Absorptivity: 0.70 Sketch of Construction Assembly Roughness= Glass, Paint on Pine, ASSEMBLY U -VALUE Tb R -Value Construction Components Fr (iioj Cavity Frame outside Air Film 0.17:: 0.17 1. Softwood, Douglas Fir -Larch -1.7-50 1 . /3•: 1.73 • 3. - 4. 6, 9. Inside Air F•iim 0.68 0.68 Unadjusted R-Vaiues 2.58: 2.58 ADJUSTMENT FOR FRAMING (1 i 2.58) x (1.UO) + 1 / 2.58j x (o.UO) = Weight: Heat Capacity: 5.1 ib/sp'i't 1.99 0.387 T O f AL U- VALUE. = 0.387 TOTAL' R-\.ALUE = 2.58 HVAC SYSTEM HEATING & COOLING LOAD SUMMARY page 22 o -i- 24 Project Name: Maggio Residence --Existing ;Date= 10/1/1999 • Documentation: BREEZE AIR CONDITIONING _----------- - ;COMPLY24-User-3665 ------------------------------------------- HVAC SYSTEM DESCRIPTION HVAC System Name= Heating System Name= Cooling System Name: System Multiplier" Fan Schedule: Peak Load Method. Relative Humidity: ZONES ON THIS SYSTEM PEAK HEATING Existing Residence (Jan 12am) 77211 rO'T ALL ZONE LUAU 77211 Existing/Addition Zone Existing FAU Existing Coad. Unit Z CA Daytime Faris COINCIDENT 50 % COOLING PEAK SENSIBLE LATENT (Aug 2pm) 82819 10234 828'19 10234 Duct Gains & Losses: /721 8282 Ventilation l 0 CFM) 0C 0 CFM) 0 0 Return Air Lighting Gain 0 Supply/Return Fan Gain= 1.0 0 TOTAL SYSTEM LOAD 84932 91101 1'0234 SYSTEM OUTPUT AT DESIGN CONDITIONS MAIN HEATING & COOLING SYSTEM 1/8000 84475 1/1-62 TO'iAL SYSTEM OUTPUT 1/8000 844/5 1/162 NO'T'E- The TOTAL SYSTEM LOAD .shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. 'These numbers include no safety factor, .and the HVAC contractor shouid. oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to.temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. • RESIDENTIAL ZONE HEADING LUAU SUMMARY page 23 of 24 Project Name= Maggio Residence --Existing ;Date= 10/1/1999 • Documentation: BREEZE AIR CONDITIONING --------------------------------------------------------------------------- WOMNLY" 24 User 3665 Zone Name: Existing Residence Design Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb Temperature: 32 F Design temperature Difference= 38 F Conduction Area U -Value TD Btu/hr R-19 Wall (W . 19 .2x6:16 ) 2134.3 • x 0.0655 x 38.0 - 5308 R-21 Wail (W.21.2x6.16). 190.0 x 0.0592 x 38.0 = 427 R-11 Wall (W.11.2x4.16) 100.0 x 0.0978 x 38.0 = 372 Solid Wood Door 26.6 x 0.3872 x 38.0 = 391 Single Clear Default(R) 19.6 x 1.1900 x 38.0 - 886 Single Clear Default( R•} 80.0 x '1.2500 x 38.0 - 3800 Single Clear Default(R j . 25.0 x 1.2800 x 38.0 - 1216 Double Clear Default(R) 25.0 x 0.7200 x 38.0 = 684 Double Clear Default(R) 64.0 x 0.7700 x 38.0 - 1873 Single Clear Default(R) 25.0 x 1.1900 x 38:0 - 1131 Single Clear Default(R) 80.0 x 1.2500 x 38.0 - 3800 Single Clear Default(R) 80,0 x 1.2800 x 38.0 = 3891 Double Clear Default(R) 53.0 x 0.7200 x 38VO - 1450 Clear Default(R) 40.0 x 0.7700 x 38.0 1170 •Double Single Clear Default(R) 10.0 x 1.1900 x 38.0 452 Single Clear Default(R) 24.0 x 1.2800 x 38.0 - 1167 Single Clear Defauit(R) 25.0 x 1.1900 x 38.0 = 1131 Single Clear Detault(R ) 7.5 x 1.2800 x 38.0 - 365 Double Clear. Default(R) 15:2 x 0.8000 x 38.0 - 462' R-19 Roof (R.19.2x8.16) 3866.8 x 0.0512 x 38.0 = "l'524 Slab on Grade Perim = 90.0 x 42 - 3735' Slab on Grade Perim = 327.0 x 42 - 13571 Infiltration: 1.00 x 0.018 x 3882 sf x 8.5 ft x 1.00 AC x 38.0 = 22404' TOTAL HOURLY HEAT LOSS FOR ZONE 17211 Heating AirFiow: 77211 stu/hr / [1.07 x 35 F Delta7j] = 2058 ctm • Internal Gain Op Frac. Area Heat Gain -Cony. RESIDENTIAL ZONE COOLING LOAF) SUMMARY" --------------------------------------------------------------------------- page 24 of 24 Project Name: Maggio Residence --Existing ;Date: 10/1/1999 • Documentation= --------------------------------------------------------------------------- BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 Zone Name= Existing Residence Design Indoor Dry Bulb Temperature= 78 F Design Outdoor Summer Dry Bulb Temperature: 112 F Design Temperature Difference:' 34 F Conduction Area U -value DETD Btu/hr R-19 Wall (W.19.2x6.16) 2134.3 x 0.0655 x 30.6 - 4215 R-21 Wail (W.21.2x6.16) 190.0 x 0.0592 x 30.6 = 044 R-11 Wail (W .11 .2x4.16) 100.0 x 0.0978 x 30.6 = 299 Solid Wood Door 26.6 x 0.3872 x 30.6 = :315 Single Clear Default(R) 19.6 x 1.1900 x 34.0 - 793 Single Clear Default(k) 80.0 x 1.2500 x 34.0 = 3400 Single Clear Default(R) 25.0 x 1.2800 x 34.0 = 1088 Double Clear Default(R) 25.0 x 0.7200 x 34.0 - 612 Double Clear Default(R) 64.0 x 0.7700 x 34.0 - 1676 Single Clear Default(R) 25.0 x 1-1900 x 34.0 = 1012 Single Clear Default(R) 80.0 x 1.2500 x 34.0 - 3400 Single Clear Defauit(R) 80.0 x 1.2800 x 34.0 = 3482 Double Clear Default(R) 53.0 x 0.7207 x 34.0 - 129/ Double Clear Default(R) 40.0 x 0.770D x 34.0 - 1047 Single Clear Default(R) 10.0 x 1.1907 x Q4.0 - 405 • Single Clear Defauit(R) 24.0 x 1.2807 x 34.0 - 1044 Single Clear Default(R) 25.0 x 1.1900 x 34.0 - 1012 Single Clear Default(R) 7.5 x 1.280D x 34.0 - 326 Double Clear Default(R) 15.2 x 0.8000 x 34.0 = 413 R-19 Roof (R . 19 .2x8 .16) 3866.8 x 0.0512 x 51.0 = 10098 infiltration: 1.00 x 0.018 x 3882 sf x 8.5 ft x 1.00 AC x 34.0 _ 20046 Shaded Unshaded Solar ----------------------- Gain Orient. --------- Area SGF ---- --- Area SGF '---- SC Single Clear Default(R) East L 0.0 x 15 --- + 25.0 x /3j ---- x 0.68 = 1240 Single Clear Defauit(R) East L 4.7 x 15 + 5.1 x 73j x 0./0 = 312 Single Clear Default(R) East L 4.7 x 15 + 5.1 x 73j x 0-70 = :312 Single Clear Detault(R) East L 0.0 x 15 + 80.0 x 73.J x 0.68 = 3966 Single Clear Default(R) South L 0.0 x 15 + 32.0 x 32j x 0.68 = 695 Single Clear Default(R) South L 0.0 x 15 + 8.0 x 32,J x 0.68 = 174 Single Clear Default(R) South 0.0 x 15 + 8.0 x 323 x 0.68 = 174 Single Clear Default(R) South L 0.0 x 15 + 32.0 x 323 x 0.68 = 695 Single Clear Default(R) South L 0.0 x 15 + 80.0 x 323 x 0.68 = 1/39 Single Clear Default(R) South L 0.0 x 15 + 25.0 x 323 x 0.70 = 562 Single Clear Default(R) West L 0.0 x 15 + 24.0 x 73,J x 0.68 = 1190 Single Clear Default(R) West L 0.0 x 15 + 10.0 x 733 x 0.70 = 512 Single Clear Default(R) North L 0.0 x 15 + /.5 x 15j x 0.68 = 76 Single Clear Default(R) North L 0.0 x 15 + 25.0 x 15J x 0.70 = 263 Clear Default(R) South L 0.0 x 15 + 25.0 x 32j x 0.55 = 442 •Double Double Clear Defaui"(R) South L 0.0 x 15 + 64.0 x 32j x 0.53 = 1095 Double Clear Default(R) West L 0.0 x 15 + 28.0 x 73j x 0.55 = 1130 Double Clear Default(R) West L 0.0 x 15V 25.0 x. 733 x 0.55 = 1009 Double Clear Default(R) West L 0.0 x 15 + 40.0 x 73j x 0.53 = 1562 Double Clear Default(R) Skylight L 0.0 x 15 + 15.2 x152.] x 0.58 = 1352 Internal Gain Op Frac. Area Heat Gain -Cony. Lighting 1.00 x 3882.0 x 0.200 x• 3.413 - 2650 Equipment 1.00 x 3882.0 x 0,.100, x- 3.413 - 1325 Occupants 1.00. x 3882.0 x 255 / 250 - 3960 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ZONE 82819 Latent -Gain------------ Op-Frac. _Area- Heat -uaip . Cony Btu/hr Equipment 1.00 x 3882.0 x 0.000 x 3.413 - 0 Occupants 1.00 x 3882.0 x 255 / 250 3960 IntA tration 1.00 x 3882 sf x 8.5 fit x 1.00 AC x 0.190 = 6274 TOTAL HOURLY LATENT HEAT GAIN FOR ZONE 10234 Cooling AirFlow: 82819 Btu/hr. / [1.07 x 23 F Delta -'h = 3359 Uln TITLE 24 REPORT FUR: Maggio Residence --Existing plus.Addition 55-515 Riviera La Ouinta, Ca PROJECT DESIGNER: 'Robert, A. Pitchford, Design & Drafting 4i-.625 Eclectic, Suite A-2 Palm Desert, Ca 92260 ( X60) 346-2856 REPORT''PREPARED BY: Tim. Scott BREEZE AIR CONDITIONING 75-145 ST CHARLES PLACE PALM DESERT, CA 92260 (619,) 346-0855 Job Number - Date: 10/1/1999 The COMPLY 24 computer program has been used to per-r'orm the calculations surnmarized in this compliance report. This program has approval. a'nd is, authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergyS.oft, ilc (415) 883-5900. Table of Contents for Title 24 Report -------------------------------------- CoverPage ......•................................................. 1 Table of Contents ............................................... 2 Form CF-1R Certificate of Compliance................................... 3 Form MF-1R Mandatory Measures Checklist ............... ......... 5 Form P-2R Point System Summary...................................... T Form C-ZR Computer Method Summary (Points) .................. .... 9 Form ENV-3 Construction Assemblies ..... .. ....................... 15 HVAC System Loads Summary ............ .... ..'... ....... ....... 22, Gone Heating Loads Summary ... ....................... ...... .. 23 ZOrle Cooling Loads Summary........................ .............. 25 CERTIFICATE OF COMPLIANCE - Residential (part 1 of 2) CF -1R page 3 of 26 --------------------------------------------------------------------------- Project Name: Maggio Residence --Existing plus Addition '-Date: 10/1/1999 Address: 55-515 Riviera La Quinta, Ca r ;Building Permit No Designer: Robert A. Pitchford, Design & Drafting ;Checked by / Date i Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 --------------------------------------------------------=------------------- GENERAL INFORMATION Compliance Method: Climate Lone= Conditioned Floor Area: Building 'Type'. Occupancy Type Building Front Orientation: Number of Dwelling Units= Floor Construction Type; BUILDING SHELL INSULATION Component ----------------------- R-19 Wall (W . 19 .2x6.16 ) Solid Wood Door R-21 Wall (W .21 .2x6. 16 ) R-11 Wall (W . 11 .2x4.16 ) R-21 Wall (W .21 .2x6.16 ) R-38 Roof(R .38 .2x 14.16 ) R-38 Roof(R .38 .2x 14.16 ) Slab Perimeter w/R-0.0 Slab Perimeter w/R-0.0 Slab Perimeter w/R-0.0 Slab Perimeter w/R-0.0 FENESTRATION Orient. Area U -Val Front ( E Front (E) Front (E) Left (S) Left (S) Lef t (S) Lei -t ( S ) Lent (S) Bac k ( W Back (W) Bac k ( W ) Bac k ( W Bac k ( W ) Right ( N ) Right ( N Skylight • THERMAL MASS Type 19.6 80.0 25.0 40.0 64.0 25.0 80.0 80.0 9.0 141.1 40.0 10.0 24.0 25.0 7.5 55.4 1.19 1.25 1.28 0.72 0.77 1.19 1.25 1.28 0.72 0.72 0.77 1.19 1.28 1.19 1.28 0.80 r'ype Single Single Single Double Double Single Single Single Double Double Double Single Single Single Single Double COMPLY 24 version 5.10 15 4299 sqf t Exist+Add Single Fam Det 70 deg (E) 1 Slab on Grade U -Value Location/Comments ------------------------------------------- Cover i T19 --------------------- -------- Concrete, Heavyweight Exposed Concrete, Heavyweight Covered. Concrete, Heavyweight Exposed Concrete, Heavyweight Covered 0.065 Existing Residence 0.387 Existing Residence 0.059 Existing Residence 0.0913 Existing Residence 0.059 Addition 0.028 Existing Residence 0.028 Addition 0.900 Existing Residence 0.720 Existing Residence 0.900 Addition 0.720 Addition Shading Devices Frame Interior Exterior OH SF Type Std Drape none Y N Metal Std Drape Standard Bug Scr N N Metal Std Drape Standard Bug Scr.N N Metal Std Drape none N N Metal Std Drape Standard Bug Scr N N Metal Std Drape none N N Metal Std Drape Standard Bug Scr N N Metal Std Drape Standard Bug Scr N N Metal none none N N Metal Std Drape none N N Metal Std Drape Standard Bug Scr N N Metal Std Drape none N N Metal Std Drape Standard Bug Star N N Metal Std Drape none N N Metal Std Drape Standard Bug Scr N N Metal none none N N Metal Area Thick ( sf ) ( i n ) Location/Description 899 3.50: Slab on Grade 2983 3.50 Slab on Grace 196 3.50 Slab on Grace 221 3..50 Slab on Grace Z CERTIFICATE OF COMPLIANCE - Residential (part'2 of 2) CF -1R page 4 of 26 ---------------------------7----------------------------------------------- Project Name= Maggio Residence --Existing plus Addition ;Date: 10/1/1999 Documentation: BREEZE AIR CONDITIONING :COMPLY 24 User 3665 --------------------------------------------------------------------------- HVAC SYSTEMS Minimum Distrib Type System type Efficiency and Location ----------- ---------- ---------------- Furnace 0.780 AFUE Ducts in Attic' SpltAirCond10.000 SEER Ducts in Attic Duct TStat RVal Type Location/Comments ---- ------ ----------------------- 4.2 SetBck Existing/Addition Zone 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val ----------------------- ------------------ ------- --- ------ ----- ----- American G52-5OT383N Recirc-Time&Temp StorGas 2 0.60 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank pilot System Name System Type Eff Input Loss R -Val Light ----------------------- ---------------- ----- ----- ----- ----- American G52-5OT383N DomesticHW 0.820 38000 0.003 16.0 U SPECIAL FEATURES/REMARKS • COMPLIANCE STATEMENT Certificate ertificate of Compliance lists the Building features and performance specifications needed to comply with Title 24, Parts 1 & 6 of the Califor- nia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single Building plan to be built in multiple orientations, any shading feature that.is varied is indicated in the Special Featu-es/Remarks section DESIGNER or OWNER (Per Business & Professions Code) Robert A. Pitchford, Design & Drafting 41-625 Eclectic, Suite A-2 Palm Desert - 26 760 ) 34'12-A-56 c ENFORCEMENT AGENCY Name' Title - Agency: Telephone= DOCUMENTATION AUTHOR Tim Scott BREEZE AIR CONDITIONING 75-145 ST CHARLES PLACE PALM DESERT, CA 92260 619 )e 346-Ot55 (signature) (date-) signature/stamp) (date) MANDATORY MEASURES CHECKLIST (part 1 of,2) MF -1R page 5 of 26 project Name: Maggio Residence --Existing plus Addition ;Date: 10/1/1999 Documentation: BREEZE Alk CONDITIONING ;COMPLY 24 User 3665 • --------------------- ---- ------------------------------------ _--- ---- -- - NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.• items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. when this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere . in thy documents or on this checklist only. BUILDING ENVELOPE MEASURES Enforcement o Sec. 150(a): Minimum R-19 ceiling insulation.* o Sec. 150(b): Loose fill insulation manufacturers labeled R -Value. o Sec. 150(c): Minimum k-13 wall insulation in framed waAs (does not apply to exterior mass walls). o See. 150(d): Minimum R-13 raised floor insulation in ,framed floors; Minimum R-8 in concrete raised floors. • o Sec. 150(1)= Slab edge insulation - water absorption rate no greater than U.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 118: Insulation specified or installed meets Cali-ornia Energy Commission quality standards. indicate TyOe-& -orm. o Sec. 116-117: Fenestration Products,.Ext Doors & Infil:Exfil Controls a. Doors and windows between conditioned and uncondinioned spaces designed to limit air leakage. b. Manufactured fenestration products have label w/certified U -Value c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. o Sec. 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. o Sec. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and .factory -built fireplaces have: a'. Closeable metal or glass door b. -Outside air intake. with damper and control • c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -1R page 6 -of 26 ---------------------------------------7------------------------------------ Project Name: Maggio Residence --Existing plus Addition ;Date= 10/1/1999 i •Documentation: BREEZE AIR CONDITIONING ---------------;COMPLY 24 User 3665 ----------------------------------------------------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. o Sec. 150(i): Setback thermostat on all applicable heating systems. o Sec. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e,g unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tan<, non -recirculation systems, insulated (R-4 or greater. 3. All buried or exposed piping insulated in recirculation sections of hot water system. 4. Cooling system piping below 55 F insulated. 5. Piping insulated between heating source and indirect hot water tank. o sec. 150(m) Ducts and Fans * 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust systems have backdraft or automatic dampe-s. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. o Sec. 114:Pooi and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, din -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" pipe between filter and heater -for future solar heating. b: Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater, spa -eater or household cooking appliance have no continuously burning pilot light. (Exception: Non -electrical cookinD appliance with pilot < 150 Btuh) LIGHTING MEASURES • o Sec. 150(k): Lighting - 40 lumens/watt or greater for general lighting in kitchens and rooms with water clos=ts; and recessed ceiling fixtures IC (insulation cover) ap?roved. POINT SYSTEM SUMMARY P -2R page '7 of 26 ---------------------------------------------------------------------------- Project Name" Maggio Residence --Existing plus Addition ;Date: 10/1/1999• i • Documentation: BREEZE AIR CONDITIONING -;COMPLY`24 User :3665 _____--^ BUILD'I'NG DATA ------------- Conditioned Floor Area '4299 sqft Number of Stories 1 Occupancy Type Single Fam Det SCORE CARD Measure Points 1. Roof Insulation 0.0283 (U -Value) U 2. Wall Insulation 0.0650 (U -Value) -2 3. Raised Floor Insulation 0.0000 (U -Value)'' i 3a.' Controlled Vent Crawlspace - 0.0 (R -Value), ; -: U 4. Slab Edge insulation 0.7679 (f2 factor)_; 5. Infiltration Standard 0 6. Glass Heat Loss 1.02 16.9% -8 Sum 1-6 -10 7. Fenestration Heat Gain SC Orientation Area % Glass Open Eff % • _SER North--____ _3�_� __�U 8 x U�.89,= YU.7 0.78 2 East 124:6 2.9 x 0.84 = 2.4 0.78 -1 South 289.0 6.7 x 0.75 = 5.1 ,0.84 -8 West 224.0 5.2 x 0.62 = 3.3 0.92 -4 Skylight 55.4 1.3 x 0.41 = 0.5 1.00 .-3:• 8. Interior Thermal Mass 2.51 1 9. Exterior Wall Mass 0.00 U Sum 7-9 -13 10. Heating System 0 Zonal Control: No 11. Cooling System 0 12. Water Heating - 0 Point Total= -23 Point Goal: U • 0 POINT" SYSTEM SUMMARY - Existing --------------------------------------------------------------------------- Building P -2R page'8 of 26 Project Name Maggio Residence --Existing plus Addition ;.Date: 10/1/1999 •Documentation= BREEZE AIR CONDITIONING ------------ ;COMPLY 24 User 3665 BUILDING DATA ------------- Conditioned Floor Area 4299 sgft Number of Stor..ies 1 Occupancy Type Single Fam Det SCORE CARD Measure Points 1. Roof Insulation 0.0283 (U -Value) ------ U 2., Wall Insulation 0.0650 (U -Value) -2 3. Raised Floor Insulation 0.0000 (U -Value) 3a. Controlled Vent Crawlspace 0.0 (R -Value) i U 4. Slab Edge insulation 0.7679 (f2 factor)_; 5. infiltration Standard 0 6. Glans Heat Loss 1.02 16.9% -8 Sum '1-6 -10' 7. Fenestration Heat Gain SC Orientation Area %Glass Open Eff% SER • -- -- - North 32.5 0.8 x 0.89 = 0.7 0.78 2 East 124.6 2.9 x 0.84 = 2.4 0.78 -1' South 289.0 6.7 x. 0.75 = 5.1 0.84 "8 West 224.0 '5.2 x. 0.62 = 3.3 0.92 -4 Skylight 55.4 1.3 x 0.41 = 0.5 1.00 -3 8. Interior Thermal Mass 2.51 1 9. Exterior Wall Mass 0.00 0 Sum 7-9 -13 10. Heating System 0 Zonal.Control: No 11. Cooling System 0 12. Water Heating - 0 P -Dint TTota'! -23 P -Dint Goal' 0 0 COMPUTER METHOD SUMMARY ( part 1 of 3 ) . C -2R page 9 of 26 ---------------------------------------------------------------------------- Project Name: Maggio Residence --Existing plus Addition ;mate: 10/1/1999 Documentation: BREEZE ATR CONDITIONING ---------------;COMPLY-24-User-3665 ---------------------------------------- POINT SYSTEM COMPLIANCE SUMMARY Proposed Design Point Score Budget Compliance Point Goal GENERAL INFORMATION Compliance Method: Climate Zone: Conditioned,Floor Area: Building Type: Occupancy Type: Building Front orientation: Number of Dwelling Units: Number of Stories: Floor Construction Type: Total Conditioned Volume: Conditioned Footprint Area: Ground Floor Area: -23 Points *BUILDING DUES NOT COMPLY* 0 Points COMPLY 24 version 5.-_0 15 4299 sqft Exist+Add Single Fam Det 70 deg ( E ) 1 1 Slab on Grade 36542 tuft 4299 sgft 4299 sgft BUILDING ZONE INFORMATION Floor # of Vent Zone Name Area Volume Units Zone Type VStat.Type Hgt Area Existing/Addition Zone 4299 36542 1.00 Conditioned -setback 2 n/a OPAQUE SURFACES Act Solar Type Area U -Val Azm Tilt Gains Form 3 Reference LDcation/Comments ZONE NAME = Existing/Addition Zone Wali 266 0.065 70 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Door 27 0.387 70 90 Yes Solid Wood Door. Existing Residence Wall 671 0.065 160 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 358 0.065 250 90 Yes R719 Wall (W.19.2x6.16) Existing Residence Wall 840 0.065 340 90 Yes k-19 Wall (W.19.2x6.16) Existing Residence Wall 20 0.059 70 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 51 0.059 160 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 119 0.059 250 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 56 0.098 160 90 Yes R-11 Wall (W.11.2x4.16) Existing Residence Wall 44 0.098 250 90 Yes R-11 Wall (W.11.2x4.16) Existing Residence Roof 3867 0.028 70 22 Yes R-38 Roof(R.38.2x14.16) Existing Residence Wall 36 0.059 70 90 Yes R-21 Wall (W.21.2x6.16) Addition Wall 198 0.059 160 90 Yes R-21 Wall (W.21.2x6.16) Addition Wall 224 0.059 250 90 Yes R-21 Wall (W.21.2x6.16) Addition Wall 72 0.059 340 90 Yes R-21 Wall-(W.21.2x6.16) Addition Roof 377 0.028 70 22 Yes R-38 Roof(R.38.2x14.16) Addition • COMPUTER ME'T'HOD SUMMARY ( part 2 of 3 ) C -2R page 10 of 26 ---------------------------------------------=----------------------------- Project Name: Maggio Residence --Existing plus Addition ;Date: 10/1/1999 •Documentation: BREEZE ATR CONDITIONING ;COMPLY 24 User 3665 -------------- ------- ---- ------------- ----______-------------- _------- ----- PERIMETER LOSSES F2 Insulation Type --------- Length ------ Factor ------ R -Val ----- Depth Location/Comments ----- ----------------------- ZONE NAME = Existing/Addition Zone Exposed 90.0 0.90 0.0 U in Existing Residence Covered 327.0 0.72 0.0 0 in Existing Residence Exposed 41.0 0.90 0.0 0 in Addition Covered 34.0 0.72 0.0 0 in Addition FENESTRATION SURFACES Sc Act Glass # -- Type ------------- Area ----- Frame ----- Div --- U -Val ----- Azm Tilt Only Location/Comments ZONE NAME = Existing/Addition Zone --- ---- ----- --------------------- 1 Wdw Front (E) 25.0 Metal No 1.28 70 90 1.00 Existing Residence 2 Wdw Front (E) 9.8 Metal No .1.19 70 90 1.00 Existing Residence 3 Wdw Front (E) 9.8 Metal No 1.19 70 90 1.00 Existing Residence 4 Wdw Front (E) 80.0 Metal No 1.25 70 90 1.00 Existing Residence 5 Wdw Left (S) 32.0 Metal No 1.28 160 90 1.00 Existing Residence 6 Wdw Left (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 7 Wdw Left (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 8 Wdw Left (S) 32.0 Metal No 1.28 160 90 1.00 Existing Residence • 9 Wdw Left (S) 80.0 Metal No 1.25 160 90 1.00 Existing Residence 10 Wdw Left (S) 25.0 Metal No 1.19 160 90 1.00 Existing Residence 11 Wdw Back (W) 24.0 Metal No 1.28 250 90 1.00 Existing Residence 12 Wdw Back (W) 10.0 Metal No 1.19 250 90 1.00 Existing Residence 13 Wdw Right (N) 7.5 Metal No 1.28 340 90 1.00 Existing Residence 14 Wdw Right (N) 25.0 Metal No 1.19 340 90 1.00 Existing Residence 15 Wdw Lett (S) 25.0 Metal No 0.72 160 90 0.65 Existing Residence 16 Wdw Left (S) 64.0 Metal No 0.77 160 90 0.65 Existing Residence 17 Wdw Back (W) "'28.0 Metal No 0.72 250 90 0.65 Existing Residence 18 Wdw Back (W) 25.0 Metal No 0.72 250 90 0.65 Existing Residence 19 Wdw Back (W) 40.0 Metal No 0.77 250 90 0.65 Existing Residence 20 Sky Front (E) 15.2 Metal No 0.80 70 0 0.46 Existing Residence 21 Wdw Lett (S) 15.0 Metal No 0.72 160 90 0.65 Addition 22 Wdw Back (W) 18.0 Metal No 0.72 250 90 0.65 Addition 23 Wdw Back (W) 9.0 Metal No 0.72 250 90 0.65 Addition 24 Wdw Back (W) 70.1 Metal No 0.72 250 90 0.65 Addition 25 Sky Front (E) 40.2 Metal No 0.80 70 0 0.46 Addition INTERIOR & EXTERIOR SHADING # -- Type ---- Interior ----------------------- Shade Type SC Exterior Shade Type Sc 1 Wdw Std Drape ---- 0.78 ----------------------- Standard Bug Screen ---- 0.87 2 Wdw Std Drape 0.78 None 1.00 3 Wdw Std Drape 0.78 None 1.00 4 Wdw Std Drape 0.78 Standard Bug Screen 0.87 • 5 Wdw Std Drape 0.78 Standard Bug Screen 0.87 6 Wdw Std Drape 0.78 Standard Bug Screen 0.87: 7 Wdw Std Drape 0.78 Standard Bug Screen 0.87 8 Wdw Std Drape 0.78 Standard Bug Screen 0.87 9 Wdw Std Drape 0.78 Standard Bug Screen 0.87 10 Wdw Std.Drape 0.78 None 1.00 11 Wdw Std Drape 0.78 Standard Bug Screen 0.87• • • 13 Wdw Std Drape 0.78 Standard Bug Screen 0.87 14 Wdw Std Drape 0.78 None 1.00 15 Wdw Std Drape 0.78 None 1.00 16 Wdw Std Drape 0.78 Standard Bug Screen -`0.87 17 Wdw Std Drape 0.78 None 1.00 18 Wdw Std Drape 0,78 None 1.00 •19 Wdw Std Drape 0.78 Standard Bug Screen 6.87 20 Shy None 1.00 None 1.00. 21 Wdw Std Drape 0.78 None 1.00 22 Wdw Std Drape 0.78 None 1.0.0 23 Wdw None 1.00 None 1.00 24 Wdw Std Drape 0.78 None 1.00 25 Sky None 1.00 None 1.00 • • COMPUTER METHOD SUMMARY ( part 3. of :3 ). C -2R page 11 of 26 Project Name= Maggio Residence --Existing plus Addition ;Date: 10/1/1999 Documenta-tion:,,BREEZE ATR CONDITIONING ;COMPLY 24'User 3665 • ----------------------------------------------------=----------------------- OVERHANGS/SIDE FINS. --Window-- ------Overhang-------- ---Left Fin--- ---Right Fin-- # Type Ht Wd Len Ht LExt'RExt Dist Len Ht Dist Len Ht 2 Wdw 6.5 1.5 4.0 0:1 4.0 4.0 3 Wdw 6.5 1.5 4.0 0.1 4.0 4.0 23 Wdw 5.0 14.0 U. 1 .2 .0 0.0 0. 1, 2.0 0.0 'THERMAL MASS Area l'hic,k Heat Inside Location Type (sf j (in) Cap Cond Form 3 Reference. R -Val Comments ZONE NAME = Existing/Addition Zone Exposes' Slab 899 3,50 28 0.98 n/a 0 -Covered.Slab 2983 3.50 28 0.98 n/a 2 Exposed Slab 196 3.50 28 0.98 n/a .0. Covered Slab 221. 3.50 28 0:98 n/a 2 HVAC SYSTEMS Minimum Distrib Type Duct 1'Stat, System Type Efficiency and Location IVal Type Location/Comments Furnace 0.780-AFUE Ducts in Attic 4.2 SetBck Existing/Addition Zone • SpltAirCond10.000 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy. Size Insu1 System Name Distribution Type Type Sys Factor (gal) R -Val• American G52 -501'383N Recirc-Time&Temp Storuas 2 0.60 50.0 12.0' AFUE WATER'HEATER EOUTPMENT DETAIL /Hec Rated Stdby_ Tank Pilot System Name System Type off Input Loss R -Val Light American G521-50T383N. 'DomesticHW 0.820 38000 0.003 16.0 0 COMPUTER METHOD SUMMARY -Existing Building ( part 1 of 3)C -2R page 12 of 26 --------------------------------------------------------------------------- Project Name: Maggio Residence --Existing plus Addition ;Date: 10/1/1999 i Documentation: BREEZE ATR CONDITIONING ;COMPLY 24 User 3665 ------------------------------------------- ------------------------------- POINT SYSTEM COMPLIANCE SUMMARY Proposed Design Point Score Budget Compliance Point Goal GENERAL INFORMATION Compliance Method: Climate Zone: Conditioned Floor Area: Building Type: Occupancy Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: Floor Construction Type: Total Conditioned Volume: Conditioned Footprint Area: Ground Floor Area: -23 Points *BUILDING DOES NOT COMPLY* U Points COMPLY 24 version 5;LO 15 4299 sqft Exist+Add Single Fam Det 70 deg ( E ) 1 1 Slab on Grade 36542 cuf t 4299 sqft 4299 sqft BUILDING ZONE INFORMATION Floor # of Vent 411 Zone Name Area Volume Units Zone Type TStat Type Hgt Area ----------------------- ----- ------ ---------------------- --- ---.---- Existing/Addition Zone 4299 36542 1.00 Conditioned Setback 2 n/a OPAUK SURFACES Act Solar -Type Area U -Val Azm Tilt Gains Form 3 Reference Location/Comments ZONE NAME = Existing/Addition Zone Wali 266 0.065 70 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Door 27-0.387 70, 90 Yes Solid Wood Door Existing Residence Wall 671 0.065 160 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 358 0.065 250 90 Yes R-19 Wall (W.19.2x6.16) Existing Residence Wall 540 0.065 340 90 Yes R-19 Wall (W.19.2x6.16) Existing,Residence Wall 20 0.059 70 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 51 0.059 160 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 119 0.059 250 90 Yes R-21 Wall (W.21.2x6.16) Existing Residence Wall 56 0.098 160 90 Yes R-11 Wall (W.11.2x4.:16) Existing Residence Wall. 44 0.098 250 90 Yes H-11,Wall (W.11.2x4.16) Existing Residence Roof 3867 0.028 70 22 Yes R-38 °Roof(R.38.2x1C16) Existing Residence Wall 36 0.059 70 90 Yes R-21 Wall (W.21.2x6.16.) Addition Wall 198 0.059 160 90 Yes R-21 Wall (W.21.2x6.16) Addition Wail 224 0.059 250 90 Yes R=21 Wall .(W.21.2x6.16) Addition Wall 72 0.059 340 90 Yes R-21 Wall (W:21.2x6.16) Addition Roof 3Z7 .0.028 7U 22 Yes R-38 Roof(R.38.2x14.16) Addition L _J COMPUTER METHOD SUMMARY -Existing Building (part 2 of 3)C -2R page 13 of 26 Project Name: Maggio Residence --Existing plus Addition ;Date: 10/1/1999 i Documentation: BREEZE AIR'CONDITIONING ;COMPLY 24 User. 3665 •--------------------------------------------------------------------------- PERIMETER LOSSES F2 insulation Type Length Factor R -Val Depth Location/Comments --------- ZONE NAME = ------ Existing/Addition ------ Zone ----- ----- ---------------=-------- Exposed 90.0 0.90 0.0 0 in Existing Residence Covered 327.0 0.72 0.0 0 in Existing Residence Exposed 41.0 0.90 0.0 win Addition Covered 34.0 0.72 0.0 0 in Addition ,FENESTRATION SURFACES Sc Act Glass # -- Type -------------- Area ----- Frame ----- Div U -Val Azm Tilt Only Location/Comments ZONE NAME = Existing/Addition --- Zone ----- --- ---- ----- --------------------- 1-Wdw Front (E) 25.0 Metal No 1.28 70 90 1.00 Existing Residence 2 Wdw Front (E) 9.8 Metal No 1.19 70 90 1.00 Existing Residence 3 Wdw Front (E) 9.8 Metal No 1.19 70 90 1.00 Existing Residence 4 Wdw Front (E) 80.0 Metal No 1.25 70 90 1.00 Existing Residence 5 Wdw Left (S) 32.0 Metal No 1.28 160 90 1.00 Existing Residence 6 Wdw Lent (S) 8.0 Metal No 1.28 160 90 1.00 Existing Residence 7 Wdw Left (S) 8.0 Metal ;No 1.28 160 90 1.00 Existing Residence 8 Wdw Left (S) 32.0 Metal No 1.28 160 90 1.00 Existing Residence 9 Wdw Left (S) 80.0 Metal No 1.25 160. 90 1.00 Existing Residence '10 Wdw Left (S) 25.0 Metal No 1.19 160 90 1.00 Existing Residence 11 Wdw Back (W) 24.0 Metal No 1.28 250 90 1.00 Existing Residence 12 Wdw.Back (W) 10.0 Metal No 1.19 250 90 1.00 Existing Residence 13 Wdw Right (N) 7.5 Metal No 1.28 340 90 1.00 Existing Residence 14 Wdw Right (N) 25.0 Metal No 1.19 340 90 1.00 Existing Residence 15 Wdw Lett (S) 25.0 Metal No 0.72 160 90 0.65 Existing Residence 16 Wdw Left (S) 64.0 Metal No 0.77 160 90 0.65 Existing Residence ii Wdw Back (W) 28.0 Metal No 0.72 250 90 0.65 Existing Residence 18 Wdw Back (W) 25.0 Metal No 0.72 250 90 0.65 Existing Residence 19 Wdw Back (W) 40._0 Metal No 0.77 250 90 0.65 Existing Residence 20 Sky Front (E) 15.2 Metal No 0.80 70 0 0.46 Existing Residence 21 Wdw Left (S) 15.0 Metal No 0.72 160 90 0.65 Addition 22 Wdw Back (W) 18.0 Metal No 0.72 250 90 0.65 Addition 23 Wdw Back (W) 9.0 Metal No 0.72 250. 90 0.65 Adldition 24 .Wdw Back ( W ) 70.1 Metal No 0.72 250 90 0.65 Addition 25 Sky Front (E) 40.2 Metal No 0.80 70 0 0.46 Addition INTERIOR & EXTERIOR SHAD'I'NG V -- Type ---_ Interior Shade Type SC Exterior Shade Type SC 1 Wdw_ ----------- Std _------- Drape _--- ---- 0.78 ----------------------- Standard Bug Screen --__ 0-.87 2 Wdw Std Drape 0.78 None 1.00 3 Wdw Std Drape 0.78 None 1.00 4'Wdw Std Drape 0.78 Standard Bug Screen 0;87 S'Wdw Std Drape 0.78 Standard Bug Screen 0.87 6,Wdw Std Drape 0.78 Standard Bug Screen 0.87 7 Wdw Std Drape 0.78 Standard Bug Screen 0.87 8 Wdw Std Drape 0.78 Standard Bug Screen 0.87 9 Wdw Std Drape 0.78- Standard [Bug Screen- 0.87 10. Wdw Std Drape 0.78 None 1.00 11•Wdw Std Drape 0.78 Standard Bug Screen 0.87 13 wdw Std Drape 14 Wdw Std Drape 15 'Wdw Std Drape .16 Wdw Std Drape 17 Wdw Std Drape 18 Wdw Std Drape •19 Wdw Std Drape 20 SKY None 21 wdw. std.Drape 22 Wdw Std Drape 23 Wdw None 24 Wdw. Std Drape 25 Sky None 0.78 Standard Bug Screen 0.8T 0.78 None 1.00 0.78 None 1.00 0.78 Standard Bug Screen '0.87 0.78 None 1'.00 0.78 None 1.00 0.78 Standard Bug. Screen 0.87 1.00 None 1.00 0.78 None 1.00 0.78 None 1.00 1.00 None 1.00 0.78 None 1.00 .1.00 None 1.00 COMPUTER METHOD SUMMARY -Existing Building ( part 3 of 3)C -2R page 14 of 26 --------------------------------------------------------=------------------- Project Name= Maggio Residence --Existing plus Addition ;Date: 10/1/1999 i Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 • ---------------------------------------------____- ____------------------- OVERHANGS/SID.E F1114S --Window-- -----Overhang------ ---Left Fin--- ---Right Fin -- a# Type Ht W Len Ht LExt RExt Dist Len Ht Dist Len Ht 2 Wdw 6.5 1.5 4.0 0.1 4.0 4.0 3 Wdw 6.5 1.5 4.01 0.1 4.0 4.0 23 Wdw 5.0 14.0 0.1 2.0 0.0 0.1 2.0 0.0 THERMAL .0 THERMAL MASS Area Thick Heat inside Location Type (sf) (in) Cap Cond Form 3 Reference R -Val . Comments ZONE NAME = Existing/Addition Zone Exposed Slab 899 3.50 28 0.98 n/a 0 Covered Slab 2983 3.50 28 0.98 n/a 2 Exposed Slab 196 3.50 28 0.98 n/a 0 Covered Slab 221 3.50 28 0.98 n/a 2 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency and Location RVal Type Location/Comments ------------------------------------- ---= ------ ----------------------- •Furnace 0.780 AFUE Ducts in Attic 4.2 SetBck Existing/Addition Zone SpitAirCond1O.000 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER'HEATiNG SYSTEMS Heater in Energy Size Insul System Mame Distribution Type Type Sys Factor ( gal ) R -Val ----------------------- ------------------ ------- --- ------ ----- ----- American G52-5O1383N Recirc-Time&"('emp StorGas 2 0.60 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot. System Name System Type Eff Input Loss R -Val Light ----------------------- ----------- ---- ----- ----- ----- American G52-5OT383N DomesticHW 0.820 38000 0.003 16.0 0 SPECIAL FEATURES/REMARKS • \ PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 15 of 26 _________---_________________-______________________--___-�______-_____-____ Proj*c't Name: Maggio Residence --Existing plus Addition /bate: I0/I.1999� Documentation. BREEZE AIR CONDITIONING /COMPLY 24 User 3665 ----------------------------------------------------------- __________-____ COMPDNEMT­DESCRIPTION Assembly Name.: R -II Wall (\�'1l�2x4'l61 � l ' ___________________________�_-_ | / Aooembly 'Type: Wall � | | Assembly Tilt: 90 deg (Vertical) ------------------------------- Sketch of Construction Assembly Framing Material: Wood ' Framing Spacing: ^ O.C.' ' Framing Percent: 15'0 % ` Absorptivity: 0 7O ' Roughness: Stucco, Wood Shingles ASSEMBLY U -VALUE Th R -Value Construction Components --------------------------------- Fr, (in) Cavity Frame _____-__-______________--_______--_____-__ Outside Air Film 0'I7, O'I7 l' 6tuoco0'815 0'17 0.17 2' Membrane, Vapor-Perm*6ble Felt 0'010 0'06^ — 3' Insulation, Mineral Fiber,'R-11 3.500 .` II'00 .0'06 3.46 4' Gypsum or Plaster Board ` � 0'500 0'45 0'45 5' 6' 7' . .8' � g_ �inside Air Film -------------------------------------------------- 0'68 0'68 unadjusted ` � - a ueo R V l 12'�3 _____ 5'00 ADJU6T1viEMT :FOR FRAMING (l /12'53) x (O'8,5) + (1 / 5.Oo) x '0'15` Weight: ' Heat Capacity: 12'3 lb/aqft 2'87 ' . = 0'O98 TOTAL U -VALUE = 0'098 ===== TOTALR-VAL ' = 'I0'22 ===== • E 0 PROPOSED CONSTRUCTION ASSEMBLY •Er4V-3 page 16 of 26 --------------------------------------------------------------------------- Project Name: Maggio Residence --Existing plus Addition ;Date. 10/1/1999 Documentation= BREEZE A'I'R CONDITIONING ;COMPLY 24 User 3665 COMPONENT DESCR'I'PTION ------------------------------- ------------------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name= R-19 Wall (W.19.2x6.16) Assembly Type. Wall Assembly Tilt* 90 deg (Vertical) Framing Material= Wood Framing Spacing: O.C. Framing Percent: 15.0 Absorptivity: 0.70 Roughness: Stucco, Wood Shingles AUJUSTMEN'f FOR FRAMING �1 /19.33) x (0.85) + (1 / 6.98) x (10.15) - 0.065 Weight= Heat Capacity= 18.2 lb/sgft 3.23 TOTAL U -VALUE = 0.065 TOTAL R -VALUE'= 15.28 T t'i R -Value Construction Components Fr (in)- Cavity Frame outside Air Film U.17 U.17 1. Stucco 0.8:5 0.17 0.17 2. Membrane, Vapor -Permeable Felt 0:0_0 0.06 0.06 3. Insulation, Mineral Fiber, R-17.8 * 5.500 1,7.80 5.45 4. Gypsum or Plaster Board 0.500 0.45 0.45 5. 6. 7. 8. 9 inside Air Film --------------------------------------------------------------------------- 0.68 0.68 Unadjusted R -Values 19.33 6.98 AUJUSTMEN'f FOR FRAMING �1 /19.33) x (0.85) + (1 / 6.98) x (10.15) - 0.065 Weight= Heat Capacity= 18.2 lb/sgft 3.23 TOTAL U -VALUE = 0.065 TOTAL R -VALUE'= 15.28 COMPONENT DESCRIPTION --------------- i i i ------------------------------ i i Sketch of Construction Assembly Assembly Name: R-21 Wali �W.21.2x6.16) Assembly Type: Wall Assembly Tilt; 90 deg (Vertical) Framing Material: Wood Framing Spacing: U.C. Framing Percent: 15.0 Absorptivity: 0.70 Roughness: Stucco, Wood Shingles ASSEMBLY U -VALUE PROPOSED CONSTRUCTION --------------------------------------------------------------------------- ASSEMBLY Erw-3 page 17 of 26 .1.h Project Name: Maggio Residence --Existing plus Addition ;Date: 10/1/1999 • Documentation: BREEZE --------------------------------------------------------------------------- AIR'CUNDIiT6N1'NG i ;COMPLY 24 User 3665 COMPONENT DESCRIPTION --------------- i i i ------------------------------ i i Sketch of Construction Assembly Assembly Name: R-21 Wali �W.21.2x6.16) Assembly Type: Wall Assembly Tilt; 90 deg (Vertical) Framing Material: Wood Framing Spacing: U.C. Framing Percent: 15.0 Absorptivity: 0.70 Roughness: Stucco, Wood Shingles ASSEMBLY U -VALUE .1.h R -Value Construction Components --------------------------------------------------------------------------- Fr (im) Cavity Frame Outside Air Film 0.17 0.17 1. Stucco 0.8:15 0.17 07.17 • 2. Membrane, Vapor -Permeable Felt 0.0=0 0.06 0.06 ' 3. Insulation, Mineral Fiber, R-21 * 5.500 21.00 5.45 4. Gypsum or Plaster Board 0.500 0.4S 0.45 5 6. 7 9. Inside Air Film ---------------------------------------------------------------------------- 0.68 0.68 unadjusted R -Values 22.53 6.98 ADJUSTMENT FOR FRAMING (.1 /22.53) x 0. 85) + (1 / 6.98 ) x 0.15j Weight: 13.2 lb/sgft Heat Capacity= 3.23 0 0.059 TOTAL U -VALUE = 0.059 1O A,L R -VALUE = 16.89 COMPONENT DESCRIPTION ------------------------------- ------------------------------ Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-38 Roof(R .38 .2x14.16 ) Assembly Type: Roos - Assembly Tilt: 22 deg (Tilted Up) Framing Material: Wood Framing Spacing; O.C. Framing Percent: 10.0 Absorptivity: 0.70 Roughness: Concrete,' Asph. Shingles PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 18 of,26 Fr (i -i) Project Name= Maggio Residence --Existing plus Addition ;Date: 10/1/1999 i Documentation: BREEZE ------------------------------------------------------------------------ ATR CONDITIONING ;COMPLY Z4 User.3665 COMPONENT DESCRIPTION ------------------------------- ------------------------------ Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-38 Roof(R .38 .2x14.16 ) Assembly Type: Roos - Assembly Tilt: 22 deg (Tilted Up) Framing Material: Wood Framing Spacing; O.C. Framing Percent: 10.0 Absorptivity: 0.70 Roughness: Concrete,' Asph. Shingles ADJUSTMENT FOR FLAMING (1 /41.13) x (0.90) + (1 /15.4/) x (0.10) - 0.028 1.OTAL U -VALUE• 0.028 TOTAL R-°ALUE = 35.28 Weight: 9.4 lb/sgf t Heat. Capacity: 3.00 0 Tri R -Value Construction Components ---------------------------------------------------------------------- Fr (i -i) -Cavity Frame outside Air Film 0.17 1. Rooting, Asphalt Shingles 0:2-50 0.44 0.44 2. Membrane, Vapor -Permeable Felt 0.010 0.06 0.06 3. Plywood 0.500 0.62 0.62 4. Air Space * 1.750 0.77 1.73 5. Insulation, Mineral Fiber, R-38 * 11.500 38.00 11.39 6. Gypsum or Plaster Board 0.500 0.45 0.45 7. S. 9. Inside Air Film ---------------------------------------------------------------------------- 0.61 0.61 Unadjusted R -Values 41.13 15.47 ADJUSTMENT FOR FLAMING (1 /41.13) x (0.90) + (1 /15.4/) x (0.10) - 0.028 1.OTAL U -VALUE• 0.028 TOTAL R-°ALUE = 35.28 Weight: 9.4 lb/sgf t Heat. Capacity: 3.00 0 n 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 19 of 26 --------------------------------------------------------------------------- Project Name: Maggio Residence --Existing plus Addition';Date: 10/'1/1999 Documentation: BREEZE AIR ICONDITIONING ;COMPLY 24 User.3665 --------------------------------------------------------------------------- COMPONENT DESCRIPTION Assembly Name: Carpeted Slab On Grade ------------------------------- .Sketch oy- Construction Assembly ASSEMBLY U -VALUE Assembly Type: Floor Assembly milt: 180 deg (Horizontal Floor) Framing Material= Nome Framing Spacing: O.C. Framing Percent 0.0 Absorptivity 0.00 Roughness: Concrete, Asph. Shingles Weight: Heat Capacity: 210.9•lb/sgft 42.19 Th R -Value Construction Components --------------------------------------------------------------------------- Fr (in) Cavity Frame Outside Air Film 0.17 0.17 1. Earth 24.000 4.00 4.00 2. Concrete, 140 lb, Not Dried 3.500 0.28 0.28 3: Flooring, Carpet and Fibrous Pad 0.250 2.08 2.08 5 6. / 8. inside Air Film --------------------------------------------------------------------------- 0.92 0.92 unadjusted R -Values 7.45 7.45 ADJUSTMENT FOR FRAMING �1 i 7.45) x (1.00) +' (1 / 7.45) x (0.00) = 0.134 TOTAL U -VALUE = 0.134 TOTAL R -VALUE = 7_45 Weight: Heat Capacity: 210.9•lb/sgft 42.19 III PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 20 of 26 cavity Project Name: Maggio Residence--Existing,plus Addition ;Gate: 10/1/1999 • Documentation: BREEZE --------=------------------------------------------------------------- ATR CONDITIONING -------------------- :COMPLY ------ 24 User -8665 ------- • 0 COMPONENT DESCRIPTION ------------------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name: Exposed Slab on Grade Assembly Type: Floor Assembly Tilt: 180 deg (Horizontal Floor) Framing Material: None Framing Spacing: O.C. Framing Percent: 0.0 o Absorptivity: 0.00 Roughness: Concrete, Asph! Shingles ADJ.USTINIENT FOR FRAMING (1 / 5.37) x (1.00) + (1 / 5.37) x (0.00) Weight: Heat Capacity: 210.8 lb/sgft 42.17 0.186 TOTAL U -VALUE _ 0.186 -TO'T'AL R -VALUE = 5.37 Ti R -Value Construction Components ------------------=-------------------------------------------------------- Fr (ii) cavity Frame outside Air Film 0-17 0.17 1. Earth 24.000 4.00 4.00 2. Concrete, 140 lb, Not Dried 3.500 0.28 0.28 3. 4. 5. 6. 7 8.. 9. Inside Air Film 0.92 0.92 ------------------------------------ -------------------------------------- Unadjusted R -Values 5.37 5.3.7 ADJ.USTINIENT FOR FRAMING (1 / 5.37) x (1.00) + (1 / 5.37) x (0.00) Weight: Heat Capacity: 210.8 lb/sgft 42.17 0.186 TOTAL U -VALUE _ 0.186 -TO'T'AL R -VALUE = 5.37 PROPOSED CONSTRUCTION -ASSEMBLY ENV -3 page 21 of 26 -------------------------------------------------------------------=------- ..Project Name:.Maggio:Residence--Existing.plus Addition ;Date: 10/1/1999. Documentation: -BREEZE ATR •CONDITIONING---�VICOMPLY24 User 3665 ------------------------------------------------------------- COMPONENT DESCRIPTION Assembly Name: Solid Wood Door Assembly Type: Door Assembly 'milt: 90 deg (Vertical) Framing. Material: None Framing Spacing: O.C. Framing Percent: U.0 Absorptivity: 0.70 Sketch of Construction Assembly Roughness:. Glass, Paint on Pine ASSEMBLY U -VALUE T� R -Value Construction Components Fr (0) cavity Frame Outside Air Film 0.17 0.17 1. Softwood, Douglas Fir -Larch• 1.750 1.73 1.73 • 3. 4 6. 7. £3 9. inside Air Film 0.68. 0.68 Unadjusted R -values 2.58 2.58 ADJUSTMENT FOR FRAMING (1-/ 2.58) x (1.00) + Q / 2.58) x (0.00) Weight: 5.1 lb/sgft Heat Capacity: 1.99 0.387 TOTAL U -VALUE TOTAL R-4ALUE _ 0.387 2.58 S • 0 HVAC SYSTEM HEATING & COOLING LOAD SUMMARY page 22 of 26 ------------------------------------------------------------------------- 7- Project --------------- --------- Project Name: Maggio Residence --Existing plus Addition ;Late; 10/1/1999 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 HVAC SYSTEM DESCRIPTION HVAC System Name: Heating System name: Cooling System Name: System Multiplier: : Fan Sch6dule: Peak Load Method: Relative Humidity: ZONES ON THIS SYSTEM PEAK Existing Residence (Jan 12am) Addition (Jan 12am) TOTAL ZONE LOAD Duct Gains & Losses: Ventilation: o CFM) Return Air Lighting Gain Supply/Return Fan Gain: TOTAL SYSTEM LOAD SYSTEM OUTPUT AT DESIGN CONDITIONS MAIN HEA'T'ING & COOLING SYSTEM TOTAL SYSTEM OUTPUT HEATING 73852 11,405 85257 8526 0 0 93783- 178000 178000 Existing/Addition,Gone Existing FAU Existing Cond. Unit L CA Daytime Fans COINCIDENT 50 COOLING PEAK SENSIBLE LATENT (Aug 2pm) 77917 10234 (Aug 2pm ) 15080 1099 92997 11333 9300 0' CFM ) 0 0 0 . U 102297 11333 84475 17162 84475 17162 NOTE: The,TOTAL SYSTEM LOAD shown represents the minimu-n size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety.factor, and the HVAC contractor should oversize by a reaso.nable.margin to account for variations in weather, conditions and -the pick-up capacity required to bring th zone to temper attire as a result of a setback thermostat. Those responsible for final equipment,selection should note that Sensible and Latent -Cooling Loads are indicated to allowfor accurate comparison with manufactarer's output data,. • • RESIDENTIAL ZONE HEATING LOAD SUMMARY page 23 of 26 --------------------------------------------------------------------------- Project Name: Maggio Residence--Existing.pius Addition ;Date= 10/1/1999 i Documentation= BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 Lone Name= Existing Residence Design Indoor Dry Bulb 'T'emperature: 70 F Design Outdoor Winter Dry Bulb.Temperature� 32 F' Design temperature Difference= 38 F Conduction R-19 Wall (W . 19 .2x6.16 ) R-21 Wall (W .21 .2x6.16 ) R-11 Wall (W . 11 .2x4.16 ) Solid Wood Door Single Clear Default(R ) Single. Clear De-fault(R) Single Clear Default(R ) Double Clear Default(R ) Double Clear Default(R ) Single Clear Default(R) Single Clear Default(R )' Single Clear Defauit(R ) Double Clear Default(R) Double Clear Default(R ) Single Clear Default(R) Single Clear Default(R ) Single Clear Default(R ) Single Clear Default(R) Double Bronze Skylights R-38 Rooi-(R .38 .2x14.16 ) Siap on Grade Slab on Grade Area U -Value TD Btu/hr 2134.3 x 0.0655 x 38.0• - 5308 190.0 x 0.0592 x 38.0 - 427 10U.O' x 0.0978 x 38.0 = 3/2 26.6 x 0.3872 x 38.0 = 391 19'.6 x 1.1900 x 38.0 - 886 80.0 x 1.2500 x 38.0 = 3800 25.0 x 1.2800 x 38.0 - 1216- 25.0 x 0.7200 x 38.0 - 684 64.0 -x 0.7700 x 38.0 - 1873 25.0 x 1.1900 x 38.0 1131 80.0 x 1.2500 x 38.0 - 3800 80.0 x 1.280x) x 38.0,,= 3891 53.0 x 07.7200 x 38.0 = 1450 40.0 x 0.7700) x 38.0 = 1170 10.0 x 1.1900 x 38.0 = 452 24.0 x 1.2800) x 38.0 - 1167 25.0 x 1.1900 x 38.0 = 1131 7.5 x 1.2800 x 38.0 = 365 15.2 x 0.8000 x 38.0 462 3866.8 x 0.0283 x 38.0 = 4165 Perim = 90.0 x 42 - 3735 Perim = 327.0 x 42 - 13,571 Infiltration: 1.00 x 0.018 x 3882 sf x 85 ft x 1.00 AC x 38.0 - 22404 TOTAL HOURLY HEAT LOSS FOR ZONE 73852 Heating AirFlow: 73852 Btu/hr / {1.07 x 35 F Deltaf,)j = 1968 cfm RESIDENTIAL ZONE HEATING LOAD SUMMARY page 24 of 26 ------------------------------------------------------------------------- Pr.oject Name: Maggio Residence --Existing plus Addition ;Date= 10/1/1999 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 • ---------------------------------------------------------------------- ---- Zone. Name: Addition Design Indoor Dry Bulb -Temperature: 70 F Design Outdoor Winter Dry Bulb 'T'emperature: 32 F Design Temperature Difference= 38 F Conduction R-21 Wall ( W .21 .2x6 ..16 ) Doubie Clear Detault(R ) Double Clear Default(R) Double Ciear' Default(R ) Doubie Bronze Skylights R-38 Roof i R . 38 .2 x 14.16 ) Slab on Grade Slab on Grade Infiltration= 1:00 x.0.018 x • Heating AirFiow: 11405 Btu/hr / [1.07 x 35 F Delta f ).j = 304 cfm Area U -Value TD Btu/hr 530.0 x 0.0592 x 38.0 = 1192 15.0 x 0.7200 x 38.0 = 410 9.0 x 0.7200 x 38.0 - 246 88.1 x 0.7200 x 38.0 - 2409 40.2 x 0.8000 x.38.0 - 1222 376.8 x 0.0283. x 38.0 - 406 Perim = 41.0 x 42 = 1702 Perim = 34.0 x 42 - 1411 417 sf x 8.5 ft x 1.00 AC x. 38.0 - 2407 TOTAL HOURLY HEAT LOSS FOR ZONE 11405 11405 Btu/hr / [1.07 x 35 F Delta f ).j = 304 cfm RESIDENTIAL LONE COOLING LUAU SUMMARY page 25 of 26 --------------------------------------------------------------------------- Project Name. Maggio Residence --Existing plus Addition ;Date. 10/1/1999. Documentation: BREEZE AIR CONDIT10NING ;COMPLY 24 User .3665 --------------------------------------------------------------------------- internal Gain Op Frac. Area 'Heat Gain Conv. Gone Name: Existing Residence Design Indoor Dry Bulb 'Temperature 78 F Design Outdoor Summer Dry Bulb Temperature' 112 F DesignTemperature Difference: 34 F Conduction Area U -Value DETD Btu/hr R-19 Wall (W.19.2x6.16) 2134.3 x 0.0655 x 30.6 - 4275 R-21 Wall (W.21.2x6.16) 190.0 x 0.0592 x 30.6 - 344 R-11 Wall (W .11 .2x4 .16) 100.0 x 0.0978 x 30.6 - 299 So.lid Wood Door ' 26.6 x .0.3872 x 30.6 - 315 Single clear Default(R) 19.6 x 1.1900 x 34.0 - 793 Single clear Default(R) 80.0 x 1 .2501) x 34.0 - 3400 Single Clear Detault(R) 25.0 x 1.2800 x 34.0 - 1088 Double Clear Defauit(R) 25.0 x 0.7200 x 34.0 = 612 Double Clear Default(R) 64.0 x 0.7700 x 34.0 - 1676 Single Clear Default(R) 25.0 x 1.1900 x 34.0 - 1012 Single Clear Default(R) 80.0 x 1.2500 x 34.0 - 3400 Single Clear Default(R) 80.0 x 1.2800 x 34.0 - 3482 Double Clear Detault(R) 53.0 x 0./200 x 34.0 - 1297 Double Clear Dei-ault(R) 40.0 x 0.7700 x 34.0 = 1047 Single Clear Default(R) 10.0 x 1.1900 x 34.0 - 405 • Single Clear Det ,ault(R) 24.0. x 1.2809 x 34.0' = 1044 Single Ciear Default(R) 25.0 x 1.1900 x 34.0 = 1012 Single Clear Dei-ault(R) 7.5 x 1.280D x 34.0 - 326 Double Bronze Skylights 15.2 x 0.8000 x 34.0 - 413 R-38 Roof(R.38.2x14.16) 3866.8 x 0.0283 x 51.0 - 5590 Infiltration= 1.00 x 0.018 x 3882 sf x 8.5 ft x 1.00 AC x 34.0 = 20046 Shaded Unshadad Solar Gain Orient. Area SGF Area 3GF SC Single Clear Default(R) East E 0.0 x 15 + 25.0 x 73,J x 0.68 = 1240 Single Clear Default(R) East E 4.7 x 15 + 5.1 x 73] x 0.70 = 312 Single Clear Default(R) East C 4.7 x 15 + 5.1 x 73,J x 0.70 = 312 Single Clear Default(R) East C 0.0 x 15 + 80.0 x 73j x 0.68 = 3966 Single Clear Default(R) South 0.0 x 15 + 32.0 x 32,J x 0.68 = 695 Single Clear Defauit(R) South 0.0 x 15 + 8.0 x 32j x 0.68 = 174 Single Clear Defauit(R) South [ 0.0 x 15 + 8.0 x 32j x 0.68 = 174 Single Clear Default(R) South [ 0.0 x 15 + 32.0 x 32j x 0.68 = 695 Single clear Default(R) South L 0.0 x 15 + 80.0 x 32j x 0.68 = 1739 Single Clear Defauit(R) South C 0.0 x 15 + 25.0 x 32j x 0.70 = 562 Single Clear Default(R) West L 0.0 x 15 + 24.0 x 73j x 0.68 = 1190 Single Clear Default(R) West 0.0 x 15 + 10.0 x 73J x 0.70 = 512 Single Clear Detault(R) North 0.0 x 15 + /.5 x 15,J x 0.68 = 76 Single Clear Default(R) North L 0.0 x 15 + 25.0 x 15j x 0.70 = 263 Double Clear Default(R) South L 0.0 x 15 + 25.0 x 32j x 0.55 = 442 Double Clear DefauittR) South L 0.0 x 15 + 64.0 x 321 x 0.53 = 1095 Do'ubie Clear Default(R) West 0.0 x 15 + 28.0 x 73J x 0.55 = 1130 Double Clear Default(R) West [ 0.0 x 15 + 25.0 x 73i x 0.55 = 1009 Double Clear Default(R) West L 0.0 x 15 + 40.0 x 73,j x 0.53 = 1562 Double Bronze Skylights Skylight L 0.0 x 15 + 15.2 x152] x 0.41 = 957 internal Gain Op Frac. Area 'Heat Gain Conv. Lighting 1:00 , x 3882.0 x 0.200 x 3.413 = 2650 Equipment 1.00 x 3882.0 x 0.100 x 3.413 = 1325 Occupants 1.00 x 3882.0 x 255 i 250 - 3960 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ZONE 77917 • Latent Gain Op Frac. _Area- Heat Gain C;onv. Btu/hr Equipment 1.00 x 3882.0 x 0.000 x 3.413 = 0 Occupants 1.00 x 3882.0 x 255 / 250 - 3360 11.1-i-iltration: 1.00 x 3882 sf x 8.5 ft x 1.00 AC; x 0.190 = 6274 TOTAL HOURLY LATENT HEAT GAIN FOR ZONE 10234 Cooling AirFlow= 77917 Btu/hr / [1.07 x 23 F Delta -')j = 3160 cfm 0 0 • 0 RESIDENTIAL ZONE COOLING LOAD SUMMARY page 26 of 26 Project Name: Maggio Residence --Existing plus Addition ;Date. 10/1/1999 Documentation= BREEZE AIR CONDITIONING -;COMPLY-24-User-3665 ------------------------------------------------- -- Zone Name: Addition Design indoor Dry Bulb Temperature= /8 F Design Outdoor Summer Dry Bulb Temperature:' 112 F DesignTemperature Difference= 34 F Conduction Area U -Value DETD Btu/hr R-21 Wail ( W .21 .2x6.16 ) 530.0 x 0.0592 x 30.6 - 960 Double.Clear Default(R) 15.0 x 0.7200 x 34.0 - 367 Double Clear Default(R) 9.0 x U./200 x 34.0 220 Double Clear Defauit� R ) 88.1 x 0./200 x 34.0 - 2155 Double Bronze Skylights 40,2 x 0.8.000 x 34.0 - 1093 R-38 Roof( R-38 .2x14.16 ) 376.8 x 0.0283 x 51.0 - 545 Infiltration: 1.00 x 0.018 x 417 sf x 8.5 ft x 1.00 AC x 34.0• = 2153 Shaded Unshaded Solar Gain ----------------------- Orient. Area SGF Area • SGF SC Double Clear Default(R ) --------- South [ ---- __- 0.0 x 15 + ---- -__ 15.0 x 32] x 0.55 = .265 Double Clear Default(R ) West [ 0.0 x 15 + 18.0 x /3j x 0. : 55 = • 726 Double Clear Default(R ) West [ 0.0 x 15,+ 9.0 x /3j. x 0.58 = 384 Double Clear, Default( R•) West 0.0 x 15 + 70.1 x 73j x 0.55 = .282/ Double Bronze Skylights Skylight [ 0.0 x 15 + 40.2 x"_52j x 0.41 = 2530 Internal Gain Op Frac. Area Heat Gain Conv. Lighting 1,00 x 417.0 x 0.200 'x 3.413 = 285 Equipment 1.00 x 417.0 x 0.100 x 3.413 = 142 Occupants 1.00 x 417.0 x 255 / 250 - 425 TOTAL HOURLY SENS'I'BLE HEAT GAIN FOR ZONE 15080 Latent Gain Op Frac. Area Heat, Gain Conv. Btu/hr Equipment 1.00 x 417.0 x 0.000 x 3.413 - 0 Occupants 1.00 x 417.0 x 255 / 250 - 425 infiltration: 1.00 x 417 sf x 8.5 ft x 1.00 AC x 0.190 - 674 TOTAL HOURLY LATENT HEAT GAIN .FUR ZONE 1099 Cooling AirFlow: 15080 Btu/hr / [1.07 x 23 F Delta'f )j = 612 cfm