Loading...
BRES2015-0248QuiKr(v 78-495"CALLE TAMPICO Twit D LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 ,INSPECTIONS (760) 777-7153 Application Number: BRES2015-0248 Owner: Property Address: 55661 RIVIERA M & M UKROPINA APN: 775242011 55661 RIVIERA Application Description: UKROPINA RESIDENCE REMODEL LA QUINTA, CA 922E3 Property Zoning: Application Valuation: $45,000.00 Applicant: Contractor: ROBERT PITCHFORD D & T REMODELING ]INC 77622 COUNTRY CLUB STE 0 44630 FRANKLIN COURT PALM DESERT, CA 92211 LA QUINTA, CA 922``-3 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Cla B Lic o.: 997936 Date // ° Co r" ' Contractor: / OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisionsof theIJ Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division of the Business and Professions Code) or that he or. she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant f I a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:_ Lender's Address: (760)218-6414 Llc. No.: 997936 Date: 8/17/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate a- consent to self -insure for workers' compensation, as provided for by Section 3700 o- the Labor Code, for the performance of the work for which this permit is issued. AGI have and will maintain workers' com)ensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance orrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the. work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, If I should become subject to the prkers' compensation provisions of Section 3700 of the Labor Code, I hw Comply i�t5serovi ' S. Dia e Applic ' WARNING: FAILURE TO SECURE WORKERS' COMHNSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAB PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR 117 SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this a )plication. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performec under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Ci -y of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applicat on becomes null and void if work is not commenced within 180 days from date of issiance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordina ices and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above" Ymentio prop �f7ispection purposes. Da Signature (Applicant or, Ag _.° . PAID PAID DATE DESCRIPTIONACCOUNT FINANCIAL .• w'' 1• CITY , ' AMOUNT:.' ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $0.00 "f PAID BY :. ' ` METHOD RECEIPT,# `. CHECK #. CLTD BY, DESCRIPTION ., ACCOUNT ;_ CITY :AMOUNT ' PAID PAID DATE. ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00 -PAID BY METHOD RECEIPT # - CHECK CLTD BY; ; DESCRIPTION ACCOUNT . QTY ' .. AMOUNT ' PAID,' PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 PAID BY METHOD RECEIPT # _. -CHECK # CLTD BY DESCRIPTION. '. - ACCOUNT QTY AMOUNT: = PAID . . PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 "PAID BY -., :' m. METHOD.. : ' RECEIPT # .. - ti`. `CHECK # `` CLTD BY: Total Paid forADDITION: $371.73 $0.00 DESCRIPTION ;>.. ' , ACCOUNT- QTY, AMOUNT _ PAID- ` PAID DATE. HOURLY PLAN CHECK - YES 101-0000-42600 2.25 $157.50 $0.00 ' PAID BY :. METHOD RECEIPT # CHECK # " CLTD BY DESCRIPTION: y ACCOUNT .`' "' : QTY AMOUNT - - .,; PAID RAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 0.75 $52.50 $0.00 .PAID BY METHOD,' RECEIPT # % CHECK'# CLT6BY Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $0.00 DESCRIPTION ACCOUNT " : QTY AMOUNT PAID =PAID'DATE. BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 'PAID BY METHOD RECEIPT# _ . CHECK#, CLTD BY.' Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID,; _ PAID DATE': RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID•BYT.' METHOD 'RECEIPT #,.' j f '-CHECK# CLTD BY DESCRIPTION ACCOUNT QTY, AMOUNT: PAID. YPAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 . • PAID BY - "' METHOD :"` RECEIPT # CHECK # . ; 'CLTD BY Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT::. PAID.; , PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $0.00 PAID BY `; METHOD ' . - • `: RECEIRT it CHECK # CLTD BY DESCRIPTION ACCOUNT, C,fTY°" "AMOUNT = PAID PAID DATE: APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $0.00 PAID BY "' METHOD . r RECEIPT # _. CHECK # CLTD BY ,DESCRIPTION :' ACCOUNT .: ",` QTY AMOUNT." = ' '.PAID PAID DATE, VENT FAN 101-0000-42402 0 $12.09 $0.00 0 PAID BY . • `: :METHOD . _:: RECEIPT # ' CHECK # ' _ • - 'CLTD BY ` : ` RECEIPT;#, .. CHECK # CLTD BY..,*. DESCRIPTION. ACCOUNT QTY- AMOUNT ; : PAID PAID:DATE` VENT FAN PC 101-0000-42600 0 $4.83 $0.00 :PAID BY ° METHOD : RECEIPT # , `'_" . m CHECK # • .' ., ` :CLTD BY Total Paid forMECHANICAL: $33.84 $0.00 DESCRIPTION ': ACCOUNT • . : QTY ' AMOUNT " PAID a ". - ', . PAID!DATE FIXTURE/TRAP 101-0000-42401 0 $36.27 $0.00 RECEIPT # PAID BY. . METHOD ;';' ; : ` RECEIPT;#, .. CHECK # CLTD BY..,*. DESCRIPTION . ACCOUNT 't :' QTY: AMOUNT = PAID PAID DAT FIXTURE/TRAP PC 101-0000-42600 0 $36.27 $0.00 PAID BY METHOD RECEIPT # `CHECK # CLTD BY -DESCRIPTION ACCOUNT''. ' QTY.. ,,. AMOUNT : PAID, PAID DATE' WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 PAID BY .` ' ' METHOO RECEIPT # _:CHECK # . `: CLTD BY ' DESCRIPTION ', .> -. ACCOUNT QTY' AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT'# :. - :CHECK'# ., .: .•'CLTD-BY Total Paid for PLUMBING FEES: $96.72 $0.00 DESCRIPTION-4.,ACCOUNT • QTY . AMOUNT 'PAID PAID; DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $21.75 $0.00 PAID'BY ' METHOD.RECEIPT;# CHEEK # CLTD BY: .,DESCRIPTION ACCOUNT " QTY AMOUNT PALD.',PAID'DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600. 0 $17.40 $0.00 PAID. BY• t' _ ; `:METHOD' RECEIPT #,-. ` CHECK # . „`` CLTD .BY; { r� 1s-_�� �.°AINIT ?AID:I PAID :. DESCRIPTION,+"?'zi r'.us.'A000UNTti:.QNi aterM+t,_, `� `. n I,. REMODEL, FIRST 100 SF 101-000.0-42400 0 $49.31 $0.00 �� t •Hca :�... �x�� �,.. y '�. .ai' - .y. .�,. c �x CLTDtBY,u'� PTL#�IJ 1F CHECK# , ., -•••• - ' r 4 7 ' ':F Y24i T YF .3,.'y J' W '"`pESCRIPTION ;sACCOUNT���x _QTY,AMOUNT'`,PAID'pPAIDNDATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $0.00 t�' 4g PAID BYtry� METHOD'` u .Ra�'i�RECEIPT.#�';�° °:' CHECK ._ t~, n� ._t..x,�t� _z_ ... Total Paid for REMODEL: $223.34 $0.00 DESGRIPTIONr-., f s)1° i�i rA00OUNT tias.' QTY AMOUNT PAID �••fi PAID f)ATE ..`.'�,�.�f i,�'+r•i.rk3,-e,,..- ,._....,..__...,., Srr r;`zr„%.'i:�i:Yv:. .?�.'iyd,7. SMI - RESIDENTIAL 101=0000-20308 " 0 $5.85-- --$0.00- -,Y '$0.00 - ' 1f`.i *t e z :yaetq.'v ;..:,.,. Lex ,a;yd%Sw�' ME .3�;i�R ;,C .(� I THODECEIP,T#„ CHECK # LTD: BY, Total Paid for STRONG MOTION INSTRUMENTATION SMt $5:85 - $0.00 - • • $0.'00 Y t t c 't j ti .. � ,, .. ` _ .• -ter s, ` - r,rJ • 1 i . _ �•, .- i • t - V - DRi �. c Description: UKROPINA RESIDENCE REMODEL Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 7/1/2015 EVA Approved: 8/11/2015 JJO Parcel No: 775242011 Site Address: 55661 RIVIERA LA QUINTA,CA 92253 Subdivision: TR 21381-2 CM 064/031 CM 067/001 Block: Lot: 2 Issued: Lot Scl Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $45,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: OFFICE ADDITION & REMODEL PER 2013 CRC CODES. CONVERT 103 SQ. FT. GARAGE AREA TO BATHROOM AND NEW 121 SQ. FT. OFFICE AREA ed'6o Aooroved. Printed: Monday, August 17, 2015 2:32:42 PM 1 of 5 C SYSTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY.TYPE.'• };STAFF NAMES ACTION DATE-', " COMPLETION DATES= r ..r `® ;NOTES`:r°., ?k' NOTE JIM JOHNSON 7/14/2015 7/15/2015 NOTE JIM JOHNSON 8/5/2015 8/11/2015 NOTE PHILIP JUAREZ 8/17/2015 8/17/2015 SCHOOL FEE LETTER GIVEN TO CONTRACTOR SIGNED FOR IT MADE A COPY OF LETTER. PLAN CHECK COMMENTS FROM CONSULTANT JIM JOHNSON 7/15/2015 7/15/2015 RECEIVED PLAN CHECK COMMENTS - FROM CONSULTANT JIM JOHNSON 8/10/2015 8/10/2015 RECEIVED \ PLAN CHECK PICKED UP PHILIP JUAREZ 7/15/2015 7/15/2015 PLANS PICKED UP BY ROB PITCHFORD GIVEN TO KAY FORPROCESSING . Printed: Monday, August 17, 2015 2:32:42 PM 1 of 5 C SYSTEMS PLAN CHECK SENT TO STRUC TO YOUNG - REVIEWS ALREADY INPUT - DUE BACK OUTSIDE PC KAY HENSEL 7/24/201S 7/24/2015 8/6/2015 PLAN CHECK SUBMITTAL lNronMATION 'UNT�m,.14t­ ED VASQUEZ 6/30/2015 7/1/2015 j, RECEIVED zwllbo. DESCRIPTION CC CtTY, MOUNT • RESUBMITTAL ANGELICA ZARCO 7/23/2015 �4METHOD 7/23/2015 4 CALLED ROB TO INFORM HIM THE PLANS ARE READY TO TELEPHONE CALL JIM JOHNSON 8/11/2015 t ADDITION, EA 8/11/2015 ISSUE 101-0000-42400 CONDITIONS $62.36 $0.00 CONTACTS rwNAME-,TYPE ADDITIONAL 500 SF APPLICANT ROBERT PITCHFORD 77622 COUNTRY CLUB PALM DESERT CA 92211 ( Printed: Monday, August 17, 2015 2:32:42 PM 2 of 5 CBTWSYSTEMS rINANCIAL lNronMATION 'UNT�m,.14t­ j, zwllbo. DESCRIPTION CC CtTY, MOUNT ­! P AID'DATE 'RECEIPT4, .-CHECK �4METHOD IDBY 4 ADDITION, EA 101-0000-42400 0 $62.36 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 0 $17.40 $0.00 ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF im.onon.474(10 n $1.70.93 $0.00 ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $371.73 $0.00 HOURLY PLAN CHECK - 101-0000-42600 2.25 I $157.50 I $0.00 YES Printed: Monday, August 17, 2015 2:32:42 PM 2 of 5 CBTWSYSTEMS � ` ^ Phnted:rmonda�August z�2O1523Z`QP[N 3of5 ftv I --h e HOURLY PLAN CHECK - 101-0000-42600 0.75 $52.50 $0.00 YES Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $0.00 BSAS SE11473 FEE 101-0000-20306 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $0.00 RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,OOOSF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 APPLIANCE 101-0600-42402 0 $12.09 $0.00 APPLIANCE 101-0000-42600 0 $4.83 $0.00 REPAIR/ALTERATION PC VENTFAN 101-0000-42402 0 $12.09 $0.00 VENT FAN PC 101-0000-42600 0 $4.83 $0.00 Total Paid forMECHANICAL: $33.84 $0.00 FIXTURE/TRAP 101-0000-42401 0 $36.27 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $36.27 $0.00 WATER SYSTEM 101-0000-42401 0 $12.09 $0.00 INST/ALT/REP Total Paid forPLUMBING FEES: $96.72 $0.00 REMODEL, EA 101-0000-42400 $21.7S $0.00 � ` ^ Phnted:rmonda�August z�2O1523Z`QP[N 3of5 DES ION T',: ACE661SIT PARENT PROJECTS -777777777 '�PAID D BY� :CL TD CRIPT'' 5" LINT �PAID DATE _kiVIiW' PAI BY 1; 45 EVIE. PE j J SENT DATE REMODEL, EA DATE,,.% J, NON-STRUCTURAL - JIM JOHNSON 7/1/2015 7/16/2015 101-0000-42600 0 $17.40 $0.00 2WK ADDITIONAL 500 SF PC YOUNG 7/1/2015 7/16/2015 7/14/2015 REVISIONS REQUIRED STRt lr.T[,IRAI., . 2 WK REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 STRUCTURAL CALCS, PLANS ENGINEERING REMODEL, FIRST 500 SF NON-STRUCTURAL - JIM JOHNSON 7/23/2015 8/6/2015 8/5/2015 APPROVED I 101-0000-42660 0 $134.88 $0.00 I KATHRYN PC 8/6/2015 8/10/2015 READY FOR APPROVAL STRUCTURAL - 2 WK Total Paid for REMODEL: $223.34 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 .$5.85 $0.00 I FTotal Paid forSTRONG MOTION INSTRUMENTATION SMI: $5.85 $0.00 TOTALS: $1,136.37 $0.00 Printed: Monday, August 17,2015 2:32:42 PM 4 of 5 CRWYSTEMS PARENT PROJECTS REVIEWS _kiVIiW' EVIE. PE SENT DATE z; DATE,,.% J, NON-STRUCTURAL - JIM JOHNSON 7/1/2015 7/16/2015 7/14/2015 REVISIONS REQUIRED 2WK YOUNG 7/1/2015 7/16/2015 7/14/2015 REVISIONS REQUIRED STRt lr.T[,IRAI., . 2 WK STRUCTURAL CALCS, PLANS ENGINEERING NON-STRUCTURAL - JIM JOHNSON 7/23/2015 8/6/2015 8/5/2015 APPROVED 2WK KATHRYN 7/23/2015 8/6/2015 8/10/2015 READY FOR APPROVAL STRUCTURAL - 2 WK SAMUELS I Printed: Monday, August 17,2015 2:32:42 PM 4 of 5 CRWYSTEMS ' ~ ' � ' . ' � . . m - ' - � � . � ^ � �. ' � � / ` ATTACHMENTS DOC 7/14/2015 JIM JOHNSON 55-661 RIVIERA.docx 55-661 RIVIERA.docx 0 1ST REVIEW - DOC 7/14/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0248 KS 0 (ist).doc COMMENTS 1ST REVIEW - NEW CITY TRANSMITTAL DOC 7/14/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0248 0 TRANSMITTAL (ist).pdf .2ND REVIEW - NEW CITY TRANSMITTAL DOC 8/10/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0248 0 TRANSMITTAL (2nd).pdf ' ~ ' � ' . ' � . . m - ' - � � . � ^ � �. ' � � / ` ` Printed: Monday, August l7,ZU152:3Z:4ZPxx 5cf5' ^ . Bin # City of La Quinta Building 8T Safety Division R.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012. 028 Building Permit Application and Tracking Sheet Permit # �C�ES Zo h — Project Address: /,6 f�T Owner's Name: M z' (, F U141 - A. P. Number: 775 -Z -+-Z-0015 Address:rJs'�6 1 ��• Legal Description: �� '�S �� City, ST, Zip:Q(,(� Contractor: Ts -1P Telephone: Address: Project Description: City, ST, Zip: Telephone: hone• O State Lic. # : City Lie. #: Afe6-,+M., Designer: r, W V::tiC-COM. Address: 'T6 zz� CoumeBy Cw5 PW 4 City, ST, Zip:�i_M t;E5mr,(► , 5r/rE'0 L Telephone: % ........................................... n truction TY e• Occupancy: P : State Lic. # Prect type i o a cir : New cle one w Add'n .Alter Repair R r Dem 0 P Name of Contact Person: � ��� Sq. Ft.:l ZI # Stories: I • # Units: Telephone # of Contact Person: -7'60 3�',� Zj Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person oe Plan Check Balance Title 24 Cales. Plans picked up l Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impract Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Tees At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 224 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates.of Occupancy for this square footage in this proposed projec4k may now be issued.. Fees Paid.By Exzempt - Dennis Norblom Check No. Bank Name/Recipient of Certificate Telephone 760-213-6414 Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exemp d by Sh vre� Payment Recd `go.Op / `°Over/Unifier-- - Signature �cn = ��r'•7 �� NOTICE: Pursuant to Government Code Section 66020(d)(1), this serve to notify you that the 90 -day approval period n vih Gh you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project os issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behe.lf, whichever. is earlier. NOTICE: This Document NOT VALID without.embossed seal Embossed Original Building Department Applicant Copy Applicant/Receipt Copy -Accounting CERTIFICATEOF -COMPLIANCE ���FtFoso Desert Sands Unified School District 47950 Dune Palms Road ¢ BERMUDA DUNES r Date 8/17/15 La Quinta, CA 92253 CIO RANCHO MIRAGE INDIAN WELLS 1 No. 31898 (760) 771-8515�`''d' PALM DESERT LAND oT �y �Q ©sem Owner Ukropina APN # 775-242-003 - Address 55661 Riviera Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 55661 Riviera 224 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 224 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates.of Occupancy for this square footage in this proposed projec4k may now be issued.. Fees Paid.By Exzempt - Dennis Norblom Check No. Bank Name/Recipient of Certificate Telephone 760-213-6414 Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exemp d by Sh vre� Payment Recd `go.Op / `°Over/Unifier-- - Signature �cn = ��r'•7 �� NOTICE: Pursuant to Government Code Section 66020(d)(1), this serve to notify you that the 90 -day approval period n vih Gh you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project os issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behe.lf, whichever. is earlier. NOTICE: This Document NOT VALID without.embossed seal Embossed Original Building Department Applicant Copy Applicant/Receipt Copy -Accounting �l b w BUILDING ENERGY ANALYSIS REPORT 4 1 ®� PROJECT: �y0 Ukropina Residence F� v�o �OQM 55-661 Riviera �.N 4 O� La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club STE O Palm Desert, CA 92211 (760) 346-2856 Report Prepared by: t Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 6/30/2015 IN of AFE �Ep� The EnergyPro computer program has been used to perform the calculations summarized in this omplian0has approval and is # authorized by the California Energy Commission for use with both the Residential and Nonresid ntial 20V �j=riergy iciency Standards This program developed by EnergySoft, LLC — www.energ oft.com. ,t I ^�' EnergyPro 6.6 by EnergySoft User Number: 6712 0111 �t CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD Project me: Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xmi CF*RF-01 Page 1 of 8 GENERAL INFORMATION 01 Building Complies with Computer Performance' 01 Project Name Remodeled Residence 03 This building incorporates one or more Special Features shown below 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ftZ-yr) 03 Project Location 55-661 Riviera Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 2974 15 A� Number of Zones 2 16 Slab Area (ft) 2974 17f Number of Stories 1 18 Addition Cond. Floor Area 224 .19'� Natural Gas Available Yes 20 Addition Slab Area (ftZ) 224 W 21 Glazing Percentage (%) 24.3% AW COMPLIANCE RESULTS 01 Building Complies with Computer Performance' 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 06 �� 4p '41:0 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-06232015-744 HERS Provider: Report Generated at: 2015-06-30 09:54:44 ENERGY USE SUMMARY 045j 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating &J- 10.22 7.82 2.40 23.5% Space Cooling 339.32 327.63 11.69 3.4% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 8.45 8.30 0.15 1.8% Photovoltaic Offset A; a� — 0.00 0.00 -- Compliance Energy Total 41 �® 357.99 343.75 14.24 4.0% 4p '41:0 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-06232015-744 HERS Provider: Report Generated at: 2015-06-30 09:54:44 CERTIFJkE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY CFqPF-01 Pa e2of8 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: • -- None — HVAC Distribution System Verifications: A� • -_None — Domestic Hot Water System Verifications: -- None — ..�V ENERGY DESIGN RATING K//� - This is the sum of the annual TDV energy consumption for energy use components included in the perrormance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Aft Reference Reference Energy Use & Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 399.79 w el 385.55 14.24 3.6% V ` includes calculated Appliances and Miscellaneous Energy Use (AMEU) _4LW� BUILDING - FEATURES INFORMATION �! or 01 02 ,0 03 04 05 06 07 Zone Name ��►►.�.' Zone Type Number of Dwelling Zone Floor Area (ft) Avg. Ceiling Height Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) �� Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Remodeled Residence 2974 t J 1 3 2 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name ��►►.�.' Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 2750 9 DHW Sys 1 addition Cond,Rtioned HVAC1 224 9 DHW Sys 1 C.r o _d Registration Number: � Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stan �dafds - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-30 09:54:44 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IWOD Project me: Remodeled Residence C culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchf6rd-15.xmi CFRF-01 e3of8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition 80d Wall ex residence R-13 Wall 80 Front 1475 147.1 90 Existing No 170d Wall ex residence R-13 Wall 170 Left 1875 175.2 90 Existing No 260d Wall ex residence R-13 Wall 260 Back 1475 286 90 Existing No 350d Wall ex residence R-13 Wall 350 Right 1875 27 90 Existing No Roof residence Defaul: 1978 to present 0 2750 Existing No 80d Wall addition R-21 Wall (W.21.2x6.16) 80 , QW Front 240 No 90 New N/A 170d Wall addition R-21 Wall (W.21.2x6.16) 170 Left 240 90 New N/A 260d Wall addition R-21 Wall (W.21.24.16) 2600 Back 240 81 90 New N/A 350d Wall addition R-21 Wall (W.21.24.16) 35 Right 460 27 90 New N/A Roof 2 addition R-38 Roof Attic 1 224 New N/A i%. ATTIC 01 02 03 � 04 05 06 07 08 09 10 ",4-0 Radiant Statu Verified Existing Name Construction Type M Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Ex9 ti Attic residence Attic Roofresidence Ventilate 3 0.1 0.85 No No No �% Attic addition Attic Roofaddition �ntilated 3 0.1 0.85 No No New No e 0 Registration Number: ,0:�i® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stan4da ds - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-30 09:54:44 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEWOD Project me: Remodeled Residence ation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xm1 CRF -01 e4of8 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 8x6.7 80d Wall ex (Front -80) - - 1 53.6 0.71 0.60 Insect Screen (default) Existing No 1.4 sq It 80d Wall ex (Front -80) -- -- 1 1.4 0.71 0.60 Insect Screen (default) Existing No ex 6x7 80d Wall ex (Front -80) - - 1 42.0 0.71 0.60 Insect Screen (default) Existing No ex 6x5 80d Wall ex (Front -80) -- -- 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 8x6.7 2 170d Wall ex (Left -170) - - 1 053.6 0.71 0.60 Insect Screen (default) Existing No ex 4x2 170d Wall ex (Left -170) -- -- 1 7 8.0 0.71 0.60 Insect Screen (default) Existing No ex 8x6.7 3 170d Wall ex (Left -170) - - *{�/ 53.6 0.71 0.60 Insect Screen (default) Existing No ex 3x10 170d Wall ex (Left -170) -- -- &1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 6x5 2 170d Wall ex (Left -170) -- - 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 3x10 2 260d Wall ex (Back -260) -- -- 4C 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 10x8 260d Wall ex (Back -260) - -,;.jw1 � 80.0 0.71 0.60 Insect Screen (default) Existing No ex 12x8 260d Wall ex (Back -260) -- `4 1 96.0 0.71 0.60 Insect Screen (default) Existing No ex 10x8 2 260d Wall ex (Back -260) -- - 1 80.0 0.71 0.60 Insect Screen (default) Existing No ex 3x3 350d Wall ex (Right -350) -- - 1 9.0 0.71 0.60 Insect Screen (default) Existing No ex 3x3 2 350d Wall ex (Right -350) - - 1 9.0 0.71 0.60 Insect Screen (default) Existing No ex 3x3 3 350d Wall ex (Right -350) �� -- 1 9.0 0.71 0.60 Insect Screen (default) Existing No 9x9 accordian 260d Wall (Back -260) '! - 1 81.0 0.55 0.55 Insect Screen (default) New N/A 3x3 350d Wall (Right -350) ��-- -- 1 9.0 0.48 0.24 Insect Screen (default) New N/A 3x3 2 350d Wall (Right -350) j - - 1 9.00.48 0.24 Insect Screen (default) New N/A 3x3 3 350d Wall (Right -350) -- -- 1 9.0 E0.48 0.24 Insect Screen (default) New N/A `J DOORS 01 v n2 03 04 05 06 Name A; Side of Building Area (ft2) U -factor Status Verified Existing Condition Door Wall ex 20.1 0.50 Existing No e®0 Registration Number: CA Building Energy Efficiency Stand fds - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-06232015-744 HERS Provider: Report Generated at: 2015-06-30 09:54:44 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Remodeled Residence ation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CF�RF-01 P ge5of8 OPAQUE SURFACE CONSTRUCTIONS 01 02- 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 255 None 0.8 No Existing No • Cavity/ Frame: no insul. / 2x4 Top Chrd addition 224 58 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. > Inside Finish: Gypsum Board -C • Cavity / Frame: R-13 / 2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C,Q/ R 13 0.095 Siding/sheathing/decking Pia Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Tr ss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofaddition Attic Roofs Wood Framed Ceiling in. O.C�W none 0.644 Roofing: Light Roof (Asphalt Shingle) V Inside Finish. -'Gypsum Board - Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4_@ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 ®� Exterior Finish: Wood R-21 Wall (W21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking IWA SLAB FLOORS WV 01 02 �� 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 2750 255 None 0.8 No Existing No Covered Slab 2 addition 224 58 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 Quality Insulation Installation (QII) Required 02 Quality Installation of Spray Foam Insulation Not Required 03 Building Envelope Air Leakage Not Required 04 ACH @ 50 Pa Registration Number: ® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stands - 2013 Residential Compliance Report Version - CFiR-06232015-744 Report Generated at: 2015-06-30 09:54:44 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEWOD Project me: Remodeled Residence ation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xm1 CIRF-01 e6of8 WATER HEATING SYSTEMS 01 02 03 04 OS 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) 'Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 &A 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION # 40 - 01 02 03 i 04 05 06 07 Name Pipe Insulation 4" Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a te n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS a®V 01 02 03 �� 04 05 06 07 08 09 Heating System �� Cooling System > Distribution Fan Floor Area Verified Existing Name System Type Name Ducted %, Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2974 Existing No Cooling System Component 1 Component 1 System 1 1 I•=. HVAC - HEATING SYSTEMS 01 02 03 Mamp�� Tyne Efficiency Heating Component 1 Ap- CntrlFurnace Fuel -fired central furnace 80 AFUE eg® Registration Number: CA Building Energy Efficiency Stan daa"r'ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-06232015-744 HERS Provider: Report Generated at: 2015-06-30 09:54:44 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Remodeled Residence ation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CF�RF-01 Page 7 of 8 HVAC - COOLING SYSTEMS 01 02 03 ' 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A system - Status Condition Verification HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage -AW Verified Duct Design Insulation Supply Duct Return Duct Verified Duct Location Return Supply Verified Existing HERS Name Type Duct Leakage R -value Location Bypass Duct Status Condition Verification .1docation Air Distribution Ducts located in attic Existing (not E 4.2 Attic Attic None Existing No N/A System 1 specified) i s. �� . HVAC DISTRIBUTION - HERS VERIFICATION �� 01 02 03 04 01 02 03 �W" 04 05 06 _ Duct Leakage Duct Leakage -AW Verified Duct Design Name Verification Target (%)� Verified Duct Location Return Supply Air Distribution System 1 -hers -dist N/A IAQ (Indoor Air Quality) FANS p1 01 02 �03 04 05 Name IAQ CFM o�� IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 040`� Default 0 Not Required COOLING VENTILATION_ �� 01 02 03 04 Name �i Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 _ eS Registration Number: ��► CA Building Energy Efficiency Standiar'ds -2013 Residential Compliance Registration Date/Time: HERS Provider: Report Version - CF1R-06232015-744 Report Generated at: 2015-06-30 09:54:44 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JWOD Project me: Remodeled Residence C ulation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml C*RF-01 P e8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon Scott Company:' Signature Date: Scott Design and Title 24, Inc, 6/30/2015 Address: CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive City/State ip: Palm Desert, CA 92211 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT UP 1 certify the following under penalty of perjury, under the laws of the State of California: o�� 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificateo'C-ompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Comp ial nce are consistent with the inform4w< provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencyvo approval with th ing perms lic Responsible Designer Name: Respon Designer r Robert A. Pitchford .,*� Company: v to Signed: Robert A. Pitchford Design and Drafting �p Address: �� License: 77-622 Country Club STE O �® City/State/Zip: ` Phone: Palm Desert, CA 92211 (760) 346-2856 4 s®� Registration Number: CA Building Energy Efficiency Stan `da?ds - 2013 Residential Compliance u Registration Date/Time: Report Version - CF1R-06232015-744 HERS Provider: Report Generated at: 2015-06-30 09:54:44 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Ukropina Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ AdditionrAlteration Date 6/30/2015 Project Address 55-661 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,974 Addition 224 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R11 2,750 Existing Wall Wood Framed R 13 6,576 Existing Door Opaque Door - no insulation 20 Existing Slab Unheated Slab -on -Grade - no insulation 2,750 Perim = 255' Existing Roof Wood Framed Attic R38 224 New Wall Wood Framed R 21 1,072 New Slab Unheated Slab -on -Grade - no insulation 224 Perim = 58' New Demising Wood Framed R 13 224 New FENESTRATION Orientation Area ft2 I Total Area: 723 Glazing Percentage: 24.3%1New/Altered Average U -Factor: 0.53 U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (E) 127.0 0.710 0.60 none none Bug Screen Existing Left (S) 175.2 0.710 0.60 none none Bug Screen Existing Rear (VVJ 286.0 0.710 0.60 none none Bug Screen Existing Right (N) 27.0 0.710 0.60 none none Bug Screen Existing Rear (1/10 81.0 0.550 0.55 none none Bug Screen New Right (N) 27.0 0.480 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic 42 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6.6 by EnerqySoft User Number: 6712 RunCode: 2015-06-30709:55:29 /D: Pae 11 of 22 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the com Bance approach used. Lxce tions may apply, Keview the respective code section or more in ormation. Building Envelope Measures: §1 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §I 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § l 10.8(1): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 1 10.8(1) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(6): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class It vapor retarder shall be placed over the earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of ' 110.8 50.0 Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - 'I (q)' factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § I50.0(e)I B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § 150.0(e) I C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § I50.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §I10.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)213 All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-ri. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable tar outdoor service. For §I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades -the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioner) space shall have a Class I §150.00)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V-lectrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the ostside termination and the §I50.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §1 10.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-200614VAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastene I. Openings shall be sealed §I50.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greeter than %< inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall lot be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavit-_es and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive.duct tapes unless such tape is used in combination with mastic and draw bands. §I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, masticc- sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § I50.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building mus- have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment main-enance, and wind but not §I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP^ in the supply plenum. The § I50.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and d.agnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, _n every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CF -A per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field-erification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissirle methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic test:ng, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 4 2013 Low -Rise Residential Mandatory Measures Summary §I 10.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-upconnections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §1 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. 150.0(k)1 A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § I50.0(k)I B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k) I C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § I50.0(k)I D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §I50.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer §I50.0(k)2G: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § I50.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only §I50.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and §I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 4 2013 Low -Rise Residential Mandatory Measures Summary r1 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. §I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply ' ' with the applicable requirements in § 110.9, 130.0, 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for ' ' ' ' nonresidential garages in 110.9 130.0, 130. 1, 130.4, § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I 50.0(k) I 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §I50.0(k)l2B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § 110.10(e). §110.10(a)2: Low-rise multi-fami ly buildings shall comply with the requirements of §110.10(6) through §I 10.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §110.10(b)l: buildings with roofareas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice §I 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(6) through §110. 10(c) shall be provided to the occupant. § 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 1 10.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. r1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date kropina Residence 6/30/2015 System Name Floor Area HVAC 2,974 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1 6,437 Return Vented Lighting Return Air Ducts Return Fan Ventilation 446 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible La-:ent CFM Sensible Output per System 89,000 89,056 4,248 1,571 81,643 Total Output Btuh 178,000 0 Output Btuh/s ft 59.9 7,552 5,801 Cooling System 0 0 Output per System 35,500 18,990 4,297 446 20,914 Total Output Btuh 71,000 0 8,5451_114,158 0 Total Output Tons 5.9 7,552 5,801 Total Output Btuh/s ft 23.9 Total Output s ft/Ton 502.6 1 123,149 Air System CFM per System 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 2,800 Existing HVAC 48,193 16,360 178,000 Airflow cfm/s ft 0.94 Airflow cfm/Ton 473.2 Outside Air % 15.9% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 48,193 16,360 Aug 3 PM 178,000 Jan 1 AM Outside Air cfm/s ft 0.15 ote: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 63 OF 63 OF 123 OF Outside Air 446 cfm Supply Fan Heating Coil 121 OF 2,800 cfm ROOM 70 OF Return Fan 70 OF 72 OF O � 2,800 cfm COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/66°F 78/66°F 55/57°F O Outside Air 446 cfm Supply Fan Cooling Coil 57 / 58 OF 5 2,800 cfm 69.1 --- ---- % ROOM r Return Fan 72/64°F 72/64°F ;O 70/63°F 2,800 cfm Energ Pro 6.6 by EnergySoft User Number: 6712 Run Code: 2015-06-30T09:55:29 /D: Page 16 of 22 ROOM HEATING PEAK LOADS Project Name Date Ukropina Residence 6/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Time of Peak Jan 1 AM Floor Area 2,750.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 T O Conduction Default 1978 to present R-13 Wall Existing Window Wood Door Slab -On -Grade 'R-13 Wall X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT F' _ = = c = = = = = = = - = = = = = = = = = = = = Btu/hr 0.0790 46 9,994 0.1020 46 28,456 0.7100 46 20,092 0.5000 46 462 0.7300 46 8,563 0.1020 0 0 Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total ' 67,567 Infiltration:[ 1.00 X 1.064 X 2,750 X 9.00 X 0.266 /60] X 46 = 5,375 Schedule Air Sensible Area Ceiling Height ACH AT .j Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 72.941 I EnergyPro 6.6 by EnergySoft User Number: 6712 Run Code: 2015-06-30709:55:29 ID: Paqe 18 of 22 1 L� All ROOM HEATING PEAK LOADS Project Name Ukropina Residence Date 6/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name new addition Floor Area 224.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X �X X X X X X X X X X X X X X X X OT -�F- Btu/hr = 268 = 3,403 = 2,049 = 596 = 1,948 = 0 = = = = = = = = = = - = = = = = = = = = = = 8,264 46 = 438 R-38 Roof Attic 224.0 0.0260 46 R-21 Wall (W.21.2x6.16) 1,072.0 0.0690 46 LowE METAL .55.55 81.0 0.5500 46 LowE METAL .48.24 27.0 0.4800 46 Slab -On -Grade perim = 58.0 0.7300 46 'R-13 Wall 224.0 0.1020 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 224 X Area another room 9.00 X 0.266 Height ACH Page Total /60] X. AT TOTAL HOURLY HEAT LOSS FOR ROOM 8,701 EnergyPro 6.6 by EnergySoft User Number., 6712 RunCode: 2015-06-30T09:55:29 ID: Page 19 of 22 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Ukropina Residence ROOM INFORMATION DESIGN CONDITIONS 6/30/2015 Room Name altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 2, 750.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces Default 1978 to present R-13 Wall Wood Door R-13 Wall R-13 Wall R-13 Wall 'R-13 Wall Orientation (IM (E) (E) (S) (IM (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,750.0 0.0790 56.0 1,327.9 0.1020 32.1 20.1 0.5000 32.1 1,699.8 0.1020 27.1 1,189.0 0.1020 32.6 1,848.0 0.1020 29.0 511.0 0.1020 0.0 39.6 0.0 36.5 8.0 39.6 0.0 36.5 53.6 Pace Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration ex 8x6.7 1.4 sq ft ex 6x7 ex 6x5 ex 8x6.7 ex 4x2 ex 8x6.7 ex 3x10 ex 6x5 Orientation (E) (E) (E) (E) (S) (S) (S) (S) (S) Shaded Unshaded Btu/hr 12,166 4,349 323 4,701 3,948 5,466 0 1 30,9531 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X )t. GLF = = = = = = = = = 0.0 36.5 53.6 68.5 0.0 36.5 1.4 68.5 0.0 36.5 42.0 68.5 0.0 36.5 30.0 68.5 0.0 36.5 53.6 39.6 0.0 36.5 8.0 39.6 0.0 36.5 53.6 39.6 0.0 36.5 30.0 39.6 0.0 36.5 30.0 1 39.6 Page Total Btulhr 3,669 96 2,875 2,054 2,125 317 2,125 1,189 1,189 15, 640 Internal Gain Btulhr Occupants 8 2 Occupants X 245 Btuh/occ. = 2,021 Equipment 2,750 Floor Area X 0.50 w/sgft = 4,693 Infiltration: 1.064 X 0.94 X 113.43 X 42 = 4,741 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 79,7931 Latent Gain Btu/hr Occupants 8 2 Occupants X 155 Btuh/occ. = 1,279 Infiltration: 4,771 X 0.94 X 113.43 X 0.00523 - 2,649 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 Number. 6712 Run Code: 201 C. a RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ukropina Residence 6/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 2,750.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = - X X = X X = X X = X X = Pace Total o Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr ex 3x10 (lM 0.0 X 36.5 + 30.0 X 70.8 = 2,123 ex 10x8 (IM 0.0 X 36.5 + 80.0 )c 70.8 = 5,661 ex 12x8 (tM 0.0 X 36.5 + 96.0 X 70.8 = 6,794 ex 10x8 (IM 0.0 X 36.5 + 80.0 k 70.8 = 5,661 ex 3x3 (N) 0.0 X 36.5 + 9.0 x 55.8 = 502 ex 3x3 (N) 0.0 X 36.5 + 9.0 X 55.8 = 502 ex 3x3 (N) 0.0 X 36.5 + 9.0 X 55.8 = 502 X + X _ X +1 YJ - Page Total 21,745 Internal Gain Btu/hr Occupants 8 2 Occupants X 245 Btuh/occ. = 2,021 Equipment 2,750 Floor Area X 0.50 w/sgft = 4,693 Infiltration: 1.064 X 0.94 X 113.43 X 42 = 4,741 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 79,793 Latent Gain Btu/hr Occupants 8 2 Occupants X 155 Btuh/occ. Infiltration: 4,771 X 0.94 X 113.43 X 0.00523 = 2,649 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,279 Ene Pro 6.6 by Ene Soft User Number: 6712 Run Code: 2015-06-30709:55:29 /D: Page 21 of 22 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ukropina Residence 1 6/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name new addition Outdoor Dry Bulb Temperature 112 OF Floor Area 224.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Tem erature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTID Btu/hr R-38 Roof Attic (W) 224.0 x 0.0260 x 56.0 = 326 R-21 Wall (W.21.2x6.16) (E) 240.0 x 0.0690 x 32.1 = 532 R-21 Wall (W.21.2x6.16) (S) 240.0 x 0.0690 x 27.1 = 449 R-21 Wall (W 21.2x6.16) (W) 159.0 x 0.0690 x 32.6 = 357 R-21 Wall (W.21.2x6.16) (N) 433.0 x 0.0690 x 29.0 = 866 *R-13 Wall 224.0 x 0.1020 x 0.0 = 0 x x = x x = x x = Pave Total 2,530 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 9x9 accordian (W) 0.0 x 31.4 + 81.0 x 62.9 = 5,091 3x3 (N) 0.0 x 18.5 + 9.0 x 26.2 = 236 3x3 (N) 0.0 x 18.5 + 9.0 x 26.2 = 236 3x3 (N) 0.0 x 18.5 + 9.0 x 26.2 = 236 x x = x x = x + x = x x - x _ Page Total .5,799 Internal Gain Btu/hr Occupants 0.7 Occupants x 245 Btuh/occ. = 165 Equipment 224 Floor Area x 0.50 w/sgft = 382 Infiltration: 1.064 x 0.94 x 9.24 x 42 = 386 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,263 Latent Gain Btu/hr Occupants 0 7 Occupants X 1 155 Btuh/occ. = 104 Infiltration: 4,771 x 0.94 x 9.24 x 0.00523 = 216 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 104 EnemyPro 6.6 bV EneMySoft User Number: 6712 RunCode: 2015-06-30709:55:29 ID: Page 22 of 22 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project me: Remodeled Residence Ca culation DatelTime: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CF•RF-01 Page 1 of 8 GENERAL INFORMATION 01 01 Project Name Remodeled Residence 02 ,q; -_t This building incorporates features3hat require field�testing'and/orttvenfication;by a:certifiedi HERS rater: under the supervision of a CEC-approved HERS provider. 02 Calculation Description Title 24 Analysis y x' VA %-19 IV t 03 Project Location 55-661 Riviera Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 2974 15 Number of Zones 2 16 Slab Area (ft2) 2974 17 Number of Stories 1 18 Addition Cond. Floor Area 224 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 224 21 Glazing Percentage (%) 24.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance'` 02 ,q; -_t This building incorporates features3hat require field�testing'and/orttvenfication;by a:certifiedi HERS rater: under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or�more Spec4alF eatui�es shown below 1 y x' VA %-19 IV t f-- CA � Qo Z -o Number: 215-91:1 7 CA Buildknji Energy Registration Date/Time: 2015-06-30 10:02:33 - 2013 Residential Compliance Report Version - CF1R-06232015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-06-30 09:54:50 ENERGY USE SUMMARY 04 05 06 07 08 se ( TDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement e ating 10.22 7.82 2.40 23.5% o ling 339.32 327.63 11.69 3.4% 0 1 en I ion 0.00 0.00 0.00 0.0% VA -at g 8.45 8.30 0.15 1.8% O P tPPItaic set --- 0.00 0.00 -- ai> r Total 357.99 343.75 14.24 4.0% � Qo Z -o Number: 215-91:1 7 CA Buildknji Energy Registration Date/Time: 2015-06-30 10:02:33 - 2013 Residential Compliance Report Version - CF1R-06232015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-06-30 09:54:50 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD CF -ORF-01 Project ame: Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: -- None — HVAC Distribution System Verifications: — None — Domestic Hot Water System Verifications: • -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. 04 Reference Energy U'se I Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)` 3399.79f)l 11 ' - 385.55 14.24 3.6% IF includes calculated Appliances and Miscellaneous EnergyU.Nse (AM ,Uj E 11 E MIR BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Remodeled Residence 2974 1 3 2 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 2750 9 DHW Sys 1 addition Conditioned HVAC1 224 9 DHW Sys 1 Registration Number: 215-A0177535A-000000000-0000 Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-06232015-744 Report Generated at: 2015-06-30 09:54:50 CERTI,PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD . Project ame: Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CF•RF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (1`11:2) TiltExisting (deg) Status Verified Condition 80d Wall ex residence R-13 Wall 80 Front 1475 147.1 90 Existing No 170d Wall ex residence R-13 Wall 170 Left 1875 175.2 90 Existing No 260d Wall ex residence R-13 Wall 260 Back 1475 286 90 Existing No 350d Wall ex residence R-13 Wall 350 Right 1875 27 90 Existing No Roof residence Defaul: 1978 to present 2750 Existing No 80d Wall addition R-21 Wall (W.21.2x6.16) 80 Front 240 90 New N/A 170d Wall addition R-21 Wall (W.21.2x6.16) 170 Left 240 90 New N/A 260d Wall addition R-21 Wall (W.21.2x6.16) 260 Back 240 81 90 New N/A 350d Wall addition R-21 Wall (W.21.2x6.16) 350 Right 460 27 90 New N/A Roof 2 addition R-38 Roof Attic 224 New N/A ATTIC U,.� 01 , 02 1031 #k WrA 05'+ JJ'O6 � `i 07 08 09 10 a 18 0 fte, iii M 9 ' 0 Radiant Statu Verified Existing Name Construction. t. { �wT a ypp <. Roof Rise gRoof`Reftectance Roof Emittarice Barrier Cool Roof s Condition t 4 • a x x Attic residence Attic Roofresidence Ventilated H 3 v 0.1 0.85 No No E�9 t� No Attic addition Attic Roofaddition Ventilated 3 0.1 0.85 No No New No Registration Number: 215-A0177535A-000000000-0000 I Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-06232015-744 Report Generated at: 2015-06-30 09:54:50 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IWOD Project ame: Remodeled Residence C culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xmi CF,PRF-01 P ge4of8 WINDOWS 01 -02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 8x6.7 80d Wall ex (Front -80) --- -- 1 53.6 0.71 0.60 Insect Screen (default) Existing No 1.4 sq It 80d Wall ex (Front -80) -- - 1 1.4 0.71 0.60 Insect Screen (default) Existing No ex 6x7 80d Wall ex (Front -80) --- -- 1 42.0 0.71 0.60 Insect Screen (default) Existing No ex 6x5 80d Wall ex (Front -80) -- - 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 8x6.7 2 170d Wall ex (Left -170) -- --- 1 53.6 0.71 0.60 Insect Screen (default) Existing No ex 4x2 170d Wall ex (Left -170) - - 1 8.0 0.71 0.60 Insect Screen (default) Existing No ex 8x6.7 3 170d Wall ex (Left -170) --- - 1 53.6 0.71 0.60 Insect Screen (default) Existing No ex 3x10 170d Wall ex (Left -170) -- -- 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 6x5 2 170d Wall ex (Left -170) - - 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 3x10 2 260d Wall ex (Back -260) -- - 1 30.0 0.71 0.60 Insect Screen (default) Existing No ex 10x8 260d Wall ex (Back -260) ---- - 1 80.0 0.71 0.60 Insect Screen (default) Existing No ex 12x8 260d Wall ex (Back -260) -- � �1" 6.0 k 0. ,, Insect Screen (default) Existing No ex 10x8 2 260d Wall ex Back -260 (t y r i jt 1 '5 'y= 1 J � 4$0:0 S A ..-, 10.71 i k '0.60 4 Insect Screen (default) Existing No ex 3x3 350d Wall -ex,-(Right-350) _----_ _ ---_ _ 1 _ 90 0.71 6'60' � Insect Screen (default) Existing No ex 3x3 2 350d Wall ex (Right, -350) rl r ---4" --t' r% 1 ' V.0 1-0:71 C 0:60 Insect Screen (default) Existing No ex 3x3 3 350d Wall ex (Right -350) --- -- 1 9.0 0.71 0.60 Insect Screen (default) Existing No 9x9 accordian 260d Wall (Back -260) ---- - 1 81.0 0.55 0.55 Insect Screen (default) New N/A 3x3 350d Wall (Right -350) --- - 1 9.0 0.48 0.24 Insect Screen (default) New N/A 3x3 2 350d Wall (Right -350)- -- 1 9.0 0.48 0.24 Insect Screen (default) New N/A 3x3 3 350d Wall (Right -350) - -- 1 9.0 0.48 0.24 Insect Screen (default) New N/A DOORS 01 n7. q3 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition Door 80d Wall ex 20.1 0.50 Existing No Registration Number: 215-A0177535A-000000000-0000 Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-30 09:54:50 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JkOD Project me: Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml C*RF-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 255 None 0.8 No Existing No • Cavity/ Frame: no insul. / 2x4 Top Chrd addition 224 58 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofaddition Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Frame&Ceiling fl A02x4te1,6 in: O C-" R 36 j 0.025 Over Floor Joists: R-28.9 insul. L a O�L t In, 0• side Finish: Gypsum Board avity /Frame: R-21 / 2x6 Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood FramedWalg P <2x6 @ 1X -in. (1C, n '�/ R 21'" $0.066 Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 2750 255 None 0.8 No Existing No Covered Slab 2 addition 224 58 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required — Registration Number: 215-A0177535A-000000000-0000 Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version CF111-06232015-744 Report Generated at: 2015-06-30 09:54:50 CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project me: Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CF*RF-01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a "`g"" F"`�/a �n/a n/a n/a !rF 1 t .*F r 11 7 C I c-*-'- 6 r-=-.4 19 X 11 31 it it SPACE CONDITIONING SYSTEMS '` U a U. V 0 U 0 U 0 01 02 03 F R 0¢� 1 05 ' 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes CoolingYes Air Distribution HVAC Fan 2974 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Nimo Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-A0177535A-000000000-0000 Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-06232015-744 Report Generated at: 2015-06-30 09:54:50 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project e: Remodeled Residence C ulation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CFIVRF-01 P e7of8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed VerifiedDuc4Location, Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A Location system Status Condition Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage 0 VerifiedDuc4Location, Verified Duct Design Return Supply Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) HVAC DISTRIBUTION - HERS VERIFICATION H t K �> V K U V I 01 01 02 .. 03 04 05 06 SFam IAQVentRpt Duct Leakage Duct Leakage 0 VerifiedDuc4Location, Verified Duct Design Return Supply Name Verification Target (/o Air Distribution System 1 -hers -dist i` N/F1 caa`. el H – – — IAQ (Indoor Air Quality) FANS H t K �> V K U V I 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 Registration Number: 215-A0177535A-000000000-0000 Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-30 09:54:50 CERTI'JOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project 'JOE Remodeled Residence Ca culation Date/Time: 09:54, Tue, Jun 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Ukropina-Pitchford-15.xml CF P4 RF -01 Pa e8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: T&W".5� Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2015-06-30 10:02:33 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted o the enforcement -agency for approval with.tthi .building permit application. Responsible Designer Name: $ ;Responsible Designer Signature: TuXi.$eeZL` Tim Scottx Company:Date H Signed: 201506 Scott Design and Title 24, Inc. 3010:02:33 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-Ao177535A-000000000-0000 Registration Date/Time: 2015-06-30 10:02:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-30 09:54:50