Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-1354 (AR)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: b 11-00001354 56105 RIVIERA 762-021'-017- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 40000 VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: .2/10/12 Owner: CHRIS STAHL 56105 RIVIERA LA QUINTA, CA 92253 Contractor: Architect or Engineer: EDWARDS CONSTRUCTION INC,0 r 51455 DESERT CLUB .DRI'VE _,i r f.-�; 201 E LA QUINTA, CA . 92253 "" !� c (760) 777-8202 Lic. No.. 684857 LBFNrii�'..:A.o9'ef4 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Bu irfe s and Profe io9als Code, and my License is in full force and effect. License as) : B °��i nse No.: 68 857 Date: ii Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec..7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by. any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements. are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION _ I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permitis issued. My workers' compensation insurance carrier and policy number are: _ Carrier GRANITE STATE Policy Number WC1914223 I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the workers' compensation laws of California,. and agree that, if I s I&bCam e left o the workers' com nsation provisions of Section 3700 of a Labo o eo th omply with those visi s. Date„ � `� cant: ' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL' SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalfthis application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify•and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of suc er it, or cessation of work for 180 days will subject permit to cancellation. - I certify that I have read this application and state that the ab e i I f ma ion i correct. I afire o comply with all and un yordinances and state laws relating io buildi ns r ctjo , an jtrereby authori a representatives of this co nt to enter upon the above-mentioned pro e i s ctUon pur o es. Date: `— ignature (Applicant or Agent): Application Number . . . . . 11-00001354 - Permit . . BUILDING PERMIT Additional desc . Permit Fee . . . . 349.50 Plan Check Fee 227.18 Issue Date . . . . Valuation . . . . 40000 , Expiration Date 8/08/12 'Qty Unit Charge Per Extension BASE FEE 252.00 15.00 6.5000 THOU BLDG 25,001-50,000 97.5.0 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee 29.00 Plan Check Fee 7.25 Issue Date Valuation 0 Expiration Date 8/08/12 Qty Unit Charge Per Extension BASE FEE 15.00 400.00 .0350 ELEC NEW RES -:1 OR 2 FAMILY 14.00 Permit . . . MECHANICAL Additional desc . Permit.Fee . . 39.50 Plan Check Fee 9.88 Issue Date Valuation . . . 0 Expiration Date 8/08/12 Qty Unit Charge Per, Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 45.00 Plan Check Fee 11.25 Issue Date Valuation . . . . 0 Expiration Date . 8/08/12 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 6.0000 EA PLS FIXTURE 24.00 1.00 3.0000 -EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT-REP/ALT 3.00 Special Notes and Comments 400. SF DETACHED CASITA ADDITION. TYPE LQPERMIT Application Number . . . . . 11-00001354 --------------------------------------------------------------------- Special Notes and Comments V -B CONSTR. R-3 OCCUPANCY. 2010 CODES. ENGINEER: DENISE POELTLER C33446. . -------------------_----------------------------------------------- Other Fees . . . . . . BLDG STDS ADMIN (SB1473) - - 2.00 ENERGY REVIEW FEE 22.72 STRONG MOTION (SMI) - RES 4.00 Fee summary Charged Paid Credited Due Permit Fee Total 463.00 .00 .00 463.00 Plan Check`Total 255.56 .00 .00 255.56 Other Fee Total. 28.72 .00 .00 28.72 Grand Total 747.28 .00 .00 747.28 LQPERMIT Bin # City of Quinta.;. Building. &r Safety Division P.O. Box 1504, 78-495 Calle Tampico, La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit Project Address: 56—/05 V1 Owner's Name: b(f (1--v F4-5 A. P. Number: -76 Z c>0 01-7 FAddress: (V;F194 Legal Description: LXw T- A -16 -tr_ S+ 8 0 I Contractor:vkf>,F�- tE3S:>\,\,(�� City, ST, Zip: Q—L) T;N. Telephone: - Address: 51.4 5-5, DOi 15-7JE—IT GW 5 Project Description: City, ST, Zip: &J Tf� Telephone: -f-7-7 f3 ez-0 z State Lie. # ®R -7 City Lie. #.. ,4MNFFAff., Designer: m4R06;-1- �' Address: '77-6 Z -Z, City, ST, Zip: p D CA Telephone: -760 31+(0 .....State Lie. #: .. ... Name of Contact Person: q�# Construction Type: Occupan*cy-, Project type (circle one): New Add'r- Alter Repair Demo Stories*. Sq. Ft.: '400 1 _L i # Units: Telephone # of Contact Person: —7 c) Estimated Value of Project: 44 c" a,-30 —0c5) APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rec'd I TRACKING7 PERMIT FEES Plan Sets 2 Plan Check submitted mitted item Amount' Structural CaIcs. 2 Reviewed, ready an Check Deposit Truss Calcs. Called Contact Pe Plan Check Balance Title 24 CaIcs. Plans picked up onstructben Flood plain plan Plans resubmitted Mechanical Grading plan— 2' Review, ready for corrections -ne10 -Electrical 16 Subcontactor-List Called Contact Person Pilo Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correctionsrissue Developer. Impact Fee A Planning Approval Called Contact P�rson 4b A.I.P.P. A ok $1 Pub. Wks. Appr Date of permit issue w School Fees WN 5 Total Permit Fees 7, &Utt, .-O'D OV. dA&C, I- d- / 7- .1/4 - WMA9, U& 112- 441 21 CERTIFICATE OF COMPLIANCE �J�Sc9 Desert Sands Unified School District zo 4 47950 Dune Palms Road Q BERMUDA OUNES Cn RANCHO MIRAGE b Date 1/31/12 La Quinta, CA 92253 INDIANWELLS. No. 31198 (760) 771-9515 �' P LA QDESERT IN A �y QINDIO y� O Owner Christopher & Cathy Stahl Trust APN # 762-021-017 Address 56-105 Riviera Jurisdiction La Quir'ta City La, Quinta Zip 92253 Permit # Tract # No. of Units Type Detached Guest House Lot # No. _Street _S.F. .__hot# Ao. .Street S.F. Unit 1 56105 Riviera 400 Unit 6 Unrt_2- Unit -7 Unit 3' Unit 8 Unit 4 Unit 9 Unit:S Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/wailkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating on sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from.paying school fees at this time due to the foibwing. reason: Garage/CarportlOpen Patio EXEMPTION .NOT APPLICABLE This,certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 400 S.F. or $1,188.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By C/C-1st Bank -,,.Bob, Edwards Check No. 238100740 Name on the check Telephone 760/777-8202 Funding Residential By Dr. Sharon P. McGehee ; - Superintendent .' ' Fee collected /exem ted by Pa cia Barbuzza Payment Recd r = $0.00 ` $1,188.00 Over1Wvdei' .' dr Ski rr ". 3.•a k Signature NOTICE: Pursuant to Government Code Sectior0(d)(1), this will serve to notify you that the 90 -day approval period n which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this projec9 is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the Districtfs) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed ses.l Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting UVUI!U/•LUI1/rx1 U4:Ub 1'M monarch Accounting FAX No.71JU 776 5111 P-001/002 December 9, 2011, PGA WEST 11 RESIDENTIAL ASSOCIATION, INC. 39755 BERKEY DRIVE STE A PALM DESERT, CA 92211 PHONE (760) 776-5100 • FAX (760) 776-5111 Chris & Kathy Stahl 19342 Woodland Lane Huntington Beach, CA 92648 Reference: 56-105 Riviera, La Quinta, CA Architectural Change Request — Casita, Support Walls with Gate, Pavers, New Slider Dear Chris & Kathy Stahl: The Architectural and Landscape Committees for POGA WEST II Residential Association met on Decernber 8,- ZOO and reviewed and approved your architectural and landscape plans and approved with the foilowing conditions being met. • All other Architectural Rules & Regulations of PCA WEST II Residential Association dated Revised 8/1/07 pertain. • A Maintenance Agreement will be required, one will .be sent 'to you for proper execution as soon as it is prepared by counsel. • Your contractor must meet with Bob•Pantanella, Director of Community Services prior to commencing any work so .they are aware of access, parking and other regulations of the Association, Mr. Pantanella's phone numbers is 760-5641032. • All -trees must be planted 5 feet from the structures. All plants must have one bubbler per plant. In the future If the Desert Spoons grow tor exceed the space available it will be the homeowner responsibility to move them. • All plants must be warrantied for 12 months from approval of Notice of Completion . inspection. .Review by the [:ommuttee is only for general cronformance with the Architectural Rules It is the resconalbffW of the owner to fully understand and conform to.the Ardritec;Wral Rules cr/terla whether or not all tha dendes are noted OkWreview It &also the owner's hull rewaan 1,6111ty to field verify all existing ctindutfons The Comm/ttee's t/ecrsion with regard in vraiect deslon W11 be finalPlease wafer to the Archlted`ural Rules for all neoulred submittals Please contact Luis. 'Umana, Sunshine Landscape at 760/346-3999 and Joanne. Rose, the' Association Manager, prior io any Irrigation modifications associated with this change, Damage to landscaping, Le. shrubs, trees, flowers and turf is the responsiblity of the contractor. The original landscaping must be. brought back to Its original condition when the'project is completed. Approvals given by the Architectural .Committee are good for only six months from the date on the approval letter. If construction has not commenced within six months after the project approval datie, a new application must be submitted. u�l Uy/!1W'LUII/t!!(I U4:Ub.FM Monarch Accounting I'AX No. 760 776 5112 P.002/002 Page II PGA WEST II Residential Association Architectural/Landscape/Stahl 12.9.11 Upon • completfon of your project, please complete and return The Notice of Completion of Architectural Change- For additional. Information or questions, the Board has directed that you contact Joanne Rose, CCAM, Association Manager, at 760/776-5100, Ext. 32o. Sincerely, PGA WEST U Residential Association oanne Rose, CCAM Manager for the Architectural Committee . Cc: unit Arch ' j the , flyCyy,,, b eexw. , STRUCTURAL AND CIVIL ENGINEERING DENISE R. POELTLER, INC. 77.725 Enfield Lane • Unit # 130 i Palm Desert, CA 92211 30 January 2012 CITY OF LA QUINTA Department of Building and Safety 78-495 Calle Tampico La Quinta, CA 92253 RE: STAHL CASITA Job Site Address: 56-105 Riviera, PGA West Subject: Truss Acceptance Letter Homeowner:- Mr. and Mrs. Chris Stahl Dear Building Director: n CITY OF LA QUINT BUILDING & SAFETY DEPa Fo P o ROVED NSTRU��TION DArFih,1,._ = 1 I have reviewed the total deflection; live, dead, and drag loads used for the design of the gang -nail roof trusses prepared by BMC Building Materials (dated 1-10-2012), and found them in substantial conformance with the structural documents prepared by my firm. Respectfully submitted, Q�Esse� No. 334 6 Denise R. Poeltler Exp. 6-30� 11- R.C.E. 2R.C.E. 33446 i_90-? � F C �. W.O. 11-181 c cc: Robert A. Pitchford, Designer Bob Edwards Construction, Inc. (760) 772-4411 0 FAX (760) 772-4409 EleFtronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/23/2012 Electronically Siqned at Ca10ERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Draf-:ing) 1/29/2012 PERFORMANCE CERTIFICATE: Residential 1 cf 5 CFI R' -Part Project Name Mr. & Mrs.' Chris Stahl-Casita Building Type 0 Single Family ❑ Addition Alone ❑•Multi Family ❑ Existing+ Addition/Alteration Date 1/23/2012 Project Address 56-105 Riviera La Quinta California Energy Climate ZoneTotal CA.Climate Zone 15 Cond. Floor Area 400 Addition n/a 1t of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION - Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status . Roof Wood Framed Attic R-38 400 Radiant Barrier New Wall Wood Framed R-21 710 New, Slab Unheated Slab -on -Grade None 400 Perim = 77' New FENESTRATION. Orientation Area(fe) U. Exterior Factor SHGC Overhang Sidefins Shades Status Front (E) 7.0';,:;; , 0.720 0.59. 2.0 none Bug Screen New Leff (S) 12.0 '0.580, , 0.5310 0 ,.. ,;none Bug Screens, New ,�: .. k Lett (S) r 24.0 'j0:5.80 0.53 5 2 0 ', none,`.- e`Bug Screen x 4 5 , New Rear (lN),, ,;,� j 15 0 ) r ,.,10.580= 0.53 2 0 :, j „!none r" .° Bug Screen mss; y':"f'':,� � � '� pff. C i' `:'i � �. ,�+ f" .. � tee• k .. � A. _�-, t OUILUING &SAFETY n - FOR CO HVAC SYSTEMS AT Qty. Heating Min. Thermostat Status 1 Split Heat Pump 9.00 HSPF Split Heat Pump 15.7 SEER Setback New HVAC DISTRIBUTION Duct Location Heatin6 Cooling Duct Location R; -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.40 New WATER HEATING ' Ot . Type Gallons Min. Eff Distribution Status EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-23T16:33:56 ID: Pae 1 of 5 Reg: 212-N0003879A-000000000-0000 Registration Date/Time: 2012/01/23 19:35:25 HERS Provider: CalCERTS, Inc 0 Electronically Filed by Tim.Scott and Authenticated at CalCERTS.com - 1/23/2012 . Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 1/29/2012 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 '-CF-1R Project Name Mr. & Mrs. Chris Stahl-Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/23/2012 'SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIREDtVERIFICATION' _;.,,..: Items in this section require field testing and/or verification by a certified_HERS Rater The"insper, or.,must receive a „., _ com Ieted CF-4R'form foreaeh of'the. measures listed belovv for final t6.6e `given: " The Cooling,YSystem Carrier 25HCB624/FV4CNF002 includes credit for a 12.6 EER Condenser. A certified HERS rater must field verify the installation of the'correct Condenses ;i r The HVACS ystem HVAC` ncorporat®s' HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct .i leakage meets the specified cntena °t.:;-...,'- Erie Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-01-23716:33:56 ID: - Page 2 of 5 Ener Reg: 212-N0003879A-000000000-0000 Registration Date/Time: 2012/01/23 19:35:25 HERS Provider: CaICERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/23/2012 Blectronically Siqned at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Draf-ing) 1/29/2012 PERFORMANCE CERTIFICATE: Residential . Part 3 cf 5) CF -1 R Project Name Building Type © Single Family ❑ Addition Alone I Date Mr. & Mrs. Chris Stahl-Casita ❑ Multi Family ❑ Existing+ AdditiorlAlteration 1/23/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftp r Space Heating 5.26 3.24 2.02 Space Cooling 85.00 78.22 6.78 Fans 18.28 24.54 -6.26 Domestic Hot Water 52.53 52.53 0.00 Pumps 0.00 0.00 '' 0.00 Totals 161.07 158.52 2.55 Percent Better Than Standard: 1.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 150 7 Fuel Available at Site: Natural Gas (S) 234 36 Raised Floor Area: 0 _ (tM 150 15 Slab on Grade Area: 400 (N) -734 0 Average Ceiling Height: , ' 9.0 Roof -100 0 Fenestration Average U -Factor: 0.60 TOTAL: 56 Average SHGC 0.54 Fenestration/CFA Ratio: 14.5% REMARKS----` 1 r( P< K S a 514, .,qP T rt.:" ` �p .y,yF�—...r+r''i4•t .e}" PiF''-_ . t V •: i i l4 . P.. � M'r•K"'z�W-I3 '�ry ,l' t{ • F a ,� f ." r:y ;,i..: STATEMENT ,OF COMPLIANCE _ . This certificate of compliance' li�lsts the building features and specifications needed to comply with Title 24;.;iParts�1',the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that,the documentation is accurate and complete. Documentation Author - Company _ Scott Design and Title 24, Inc, 1/23/2012 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting Address 77-622 Country Club Dr. Suite O Name Robert Pitchford City/State/Zip Palm Desert Ca 92211 Phone (760) 346-2856 Signed License # Date, EnemvPro 5.1 by Ener Soft User Number. • 6712 RunCode: 2012-01-23716:33:56 ID: Page 3 of 5 Reg: 212-N0003879A-000000000-0000 Registration Date/Time: 2012/01/23 19:35:25 HERS Provider: CalCERTS; Inc Electronically,Filed by Tim Scott and Authenticated at CalCERTS.com - 1/23/2012 Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert'A. Pitchford Design & Draf=ing) 1/29/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 cf 5) CF -1 R Project Name Mr. &'Mrs. Chris Stahl-Casita Building Type m Single Family ❑ Addition Alone ❑Multi Family ❑Existing+ Addition/Alteration Date 1112312012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 - Location/Comments Roof 400 0.026 R-38 0 0 New 4.2.1-A9 Casita Wall 234 0.069 R-21 0 90 New 4.3.1-A6 Casita Wall 143 0.069 R-21 90 90 New 4.3.1-A6 Casita Wall 198 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 135 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 337 0.730 None 0 180 New 4.4.7-A1 Casita Slab 63 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS Area 'U -Factor SHGC Azm Status Glazin Type Location/Comments IDrdo 1 . 3.5 0.720 NFRC 0.59 NFRC 90 New,' Glass Block Casita 2.___ 3.5 0.720 'NFRC 0.59 NFRC 90 New Glass Block Casita `3 - 6.0 - a580 Default 0.53 Default180 New Double Non Metal Tinted •?asita 4.: 6.0 0.580 Default 0.53 Default 180 New Double Non Metal Tinted Casita 5;s , x.. 24.0 0.580 Default ._„ -, ._,0.53 Default_. - 180 New :..__ Double_Non Metal Tinted., �.•< Casita 6 Windgw.`'%1'5 0 0.580 Default,,r 0.53 Default J:,4- 270 New .'- - Double Non Metal Tinted' . ' Casita �. F'f , �f..' tfF 3 t. .. g, A a _ ff•n i �.. (wy ' +-' ��' ' � ? tS 4 �' '" d �• :'' f ° ! `.: _ .! r �» � _d;w :.it'd ,q..',. �.. �'. f•4'1Y+3l� �i; a,'i�. a, :.. / .f t'. e`y.' /F�..�. br 9:•'�.:��4 _Y aY Yn 4(. e".' :. a'�?iI�#: i:. J. � .i�s ,�s� .�Y� !t - (1) LI -Factor Type 16 -Al . Default Table from Standards, NFRC = Labeled Value - 2 SHGC Type: 116-B -'.Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t I Wd Len I H t LExt • RExt Dist Len H t Dist Len H t 1 Bug Screen s 0.76 6.7 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.7 6.0 10.0 0.1 10.0 10.0 4 Bug Screen 0.76 2.5 2.5 10.0 0.1 10.0 10.0 5 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 '3.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-01-23716:33:56 ID: Page 4 of 5 Reg: 212-N0003879A-000000000-0000 Registration Date/Time: 2012/01/23 19:35:25 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/23/2012 Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 1/29/2012 CERTIFICATE OF COMPLIANCE: Residential' Part 5 of 5 CF -1 R Project Name Mr. & Mrs. Chris Stahl-Casita Building Type G3 Single Family ❑ Addition Alone -Date ❑ Multi Family ❑ Existing+ Addition/Alteration 1,112312012 BUILDING ZONE INFORMATION Floor Area ft System Name. Zone Name New Existing Altered Removed Volume Year Built HVAC Casita 400 3,600 :4 Totals 4001 01 01 c HVAC SYSTEMS S stem Name:• Ot :' :. Heating Type Min. Ell. Cooling Type Thermostat Type Status HVAC �r. 1 'Split Heat Pump 9.00 HSPF Split Heat Pump Setback New 715.7SEER� ' y �le A'R .f -s9h� - AI «e At HVAC DISTRIBUTION X ./�.1 "0. 4.:.�...' :` ,,� ,5 4 •��-�'� : .'� -.7"" Duct ` Ducts: S stern 6me 'F Heatin -~ .Coolin - - Duct Location RValue Tested? Status ,- HVAC- Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New ❑ WATER HEATING SYSTEMS ° S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy -Factor or RE Standby Loss or Pilot Ext. Tank. Insul. R- Value Status Standard Gas 50 gal or Le .1 Small Gas All Pipes Ins 40,000 50 0.58 We n/a . Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING. Control Hot Water Piping Length ft 0 N a System Name Pipe Length Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-23716:33:56 ID: Page 5 of 5 Reg: 212-N0003879A-000000000-0000 Registration Date/Time: 2012/01/23 19:35:25 HERS Provider: CalCERTS, Inc BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. Chris Stahl-Casita 56-105 Riviera La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite, 0 Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 q CITY OF LA QUINTA RUILDINva- & SAFETY DEPT. oRPROVED ONSTRUCT 014 Job Number: DA Date: DEC 2 2 2011 12/20/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. Tris program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Buildingi Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 ;—y EnergySoft , User Number- 6712 RunCode: 2011-12-20TO8:33:32 ID: • Ask TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 14 EnergyPro 5.1 by EnergySoft Job Number. ID: laser Number: 6712 • • PERFORMANCE CERTIFICATE: Residential Part 1 cf 5 CF -1 R Project Name Mr. & Mrs. Chris Stahl-Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11212012011 Date Project Address 56-105 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 400 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -411 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 400 Radiant Barrier New Wall Wood Framed R-21 710 New Slab Unheated Slab -on -Grade None 400 Perim = 77' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (E) 7.0 0.720 0.59 2.0 none Bug Screen New Left (S) 12.0 0.580 0.53 10.0 none Bug Screen New Left (S) 24.0 0.580 0.53 2.0 none Bug Screen New Rear (W 15.0 0.580 0.53 2.0 none Bug Screen New HVAC SYSTEMS (fit . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.00 HSPF Split Heat Pump 15.7 SEER Setback New HVAC DISTRIBUTION Cuct Location Heating Cooling Duct Location F -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented E0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-12-20708:33:32 1D: Page 3 of 14 0 • PERFORMANCE CERTIFICATE: Residential Part 2 cf 5 CF -1 R Project Name Mr. & Mrs. Chris Stahl-Casita Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/4Iteration Date 11212012011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 25HCB6241FV4CNF002 includes credit for a 12.6 EER Condenser. A certified HERS raternust field verify the installation of the correct Condenser. The HVAC System HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-12-20708:33:32 /D: Page 4 of 14 0 PERFORMANCE CERTIFICATE: Residential Part 3 cf 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Chris Stahl-Casita ❑ Multi Family ❑ Existing+ AdditiorJAlteration 1 2 12 0/2 0 1 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.26 3.24 2.02 Space Cooling 85.00 78.22 6.78 Fans 18.28 24.54 -6.26 Domestic Hot Water 52.53 52.53 0.00 Pumps 0.00 0.00 0.00 Totals 161.07 158.52 2.55 Percent Better Than Standard: 1.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Are& Area Number of Dwelling Units: 1.00 (E) 150 7 Fuel Available at Site: Natural Gas (S) 234 36 Raised Floor Area: 0 (M 150 15 Slab on Grade Area: 400 (N) ?34 0 Average Ceiling Height: 9.0 Root 400 0 Fenestration Average U -Factor: 0.60 TO -AL: 56 Average SHGC: 0.54 Fenestration/CFA Ratio: 14.5% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance. lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 2/20)2011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with -.he specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope aling require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting Address 77-622 Country Club Dr. Suite O Name Robert Pitc ford City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed License # Date Ene Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2011-12-20708:33:32 /D: Pace 5 of 14 • • 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 cf 5 CF -1 R Project Name Mr. & Mrs. Chris Stahl-Casita Building Type m Single Family 0 Addition Alone 0 Multi Family O Existing+ Additior/Alteration Date 2120/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm I Tilt Status 4 Location/Comments Roof 400 0.026 R-38 0 0 New 4.2.1-A9 Casita wall 234 6.069 R-21 0 90 New 4.3.1-A6 Casita wall 143 0.069 R-21 90 90 New 4.3.1-A6 Casita wall 198 0.069 R-21 160 90 New 4.3.1-A6 Casita wall 135 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 337 0.730 None 0 180 New 4.4.7-A1 Casita Slab 63 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area 1 -1 -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 3.5 0.720 NFRC 0.59 NFRC 90 New Glass Block Casita 2 Window 3.5 0.720 NFRC 0.59 NFRC 90 New Glass Block Casita 3 Window 6.0 0.580 Default 0.53 Default 180 New Double Non Metal Tinted Casita 4 Window 6.0 0.580 Default 0.53 Default 180 New Double Non Metal Tinted Casita 5 Window 24.0 0.580 Default 0.53 Default 180 New Double Non Metal Tinted 3asita 6 Window 15.0 0.580 Default 0.53 Default 270 New Double Non Metal Tinted -�>sita (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t I Wd Ove hanq Left Fin Ri ht Fin Len H t LExt' RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 6.7 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.7 6.0 10.0 0.1 10.0 10.0 4 Bug Screen 0.76 2.5 2.5 10.0 0.1 10.0 10.0 5 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.01 2.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 6 of 14 :7 • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Mr. & Mrs. Chris Stahl-Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additior/Alteration Date 12120/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC Casita 400 3,600 Totals 400 0 0 J HVAC SYSTEMS System Name Oty. Heating Ty0e Min. Eff. Cooling Type Min. Eff. The Type Status HVAC 1 Split Heat Pump 9.00 HSPF Split Heat Pump 15.7 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE StEndby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas All Pipes Ins 40,000 50 0.58 i/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 . o a — System Name. Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 7 of 14 r L_ e MANDATORY MEASURES SUMMARY: Residential(Page 1 of 3 MF -1 R Project Name Mr. & Mrs. Chris Stahl-Cesita Date [1212012011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measure's listed on the Certificate of Compliance (CF -1'R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summ ary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. MANDATORY MEASURES SUMMARY: Residential(Page 1 of 3 MF -1 R Project Name Mr. & Mrs. Chris Stahl-Cesita Date [1212012011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measure's listed on the Certificate of Compliance (CF -1'R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summ ary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.``' 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include or: CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. §150(g): Mandato Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.30/6; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible,'o erable, and tight-fifting tight-fittingdamper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. 1, ` . Space Conditioning, Water. Heating and Plumbing System Measures: . §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupa,icies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters.' 150(h): Heating and/or coolina loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112 c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal stancard are externally wrapped with insulation havin an installed thermal resistance of R-12 or greater. §1506)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or Dther indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicEted on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections'of hot water pipes are insulated per Standards Table 150-13. " §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requi: ements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(0)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.. EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. & Mrs. Chris Stahl-Casita 11212012011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a min'mum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of U- 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with mate:-ials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions is the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and prov.,des shielding from solar radiation that can cause degradation of the material. 4150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Wble Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will albw all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve recuirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no low=:r than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an outp!jt frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a lime -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §13Qd), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units .arger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power- per linear foot of illuminated cabinet. ( EnergyPro5.1 by EnergySolf User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 9 of 14 1-7, MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. & Mrs. Chris Stahl-Casita 12/20/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not requi ed to be controlled by a manual -on occupancy sensor. §150(k)l 1' Permanently installed luminaires'located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IQ by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buJdings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building of to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EK,EPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3 Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 4130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply wah the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §11 a. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 10 of 14 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. & Mrs. Chris Stahl-Casita Date 12/20/2011 System Name HVAC Floor Area 400 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 346 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 51,000 7,471 x,050 194 7,585 Total Output Btuh 51,000 0 Output Btuh/s ft 127.5 431 290 Cooling System 0 0 Output perSystem 23,500 0 0 0 0 Total Output Btuh 23,500 0 431 1 8,334 1,050 0 Total Output ons 2.0 290 Total Output Stuh/s ft 58.8 Total Output s ft/Ton 204.3 1 8,165 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Alrflow' cfm 800 Carrier 25HCB624/FV4CNF002 18,112 2,464 31,853 Airflow cfm/s ft 2.00 Total Adjusted System Output 18,112 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 2,464 31,853 Auc 3 PM I Jan 1 AM AM low cfm/Tori 408.5 Ouiside Air % ' 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 010 Outside Air 0 cfm Supply Fan 800 cfm 70 OF 70 OF 107 OF Heating Coil 107 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Tem eratures at Time of Cooling Peak 112/78°F 79/64°F Outside Air 0 cfm 79 164 OF 79/64°F 57/56°F ,o � Supply Fan Cooling Coil 58 / 56 OF 800 cfm I......-.....__ ..................................... 46.5% 1 ROOMxv 78/ 64 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 11 of 14 • • • ROOM LOAD SUMMARY Project Name Date Mr. & Mrs. Chris Stahl-Casita 12120/2011 System' Name Floor Area HVAC 400 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible I Latent CFM I Sensible Casita Casita I 1 3461 7,4711 1,050 3461 7,4711 1,0501 194 ' 7,585 PAGE TOTAL TOTAL' 346 1 7,471 1,050 194 7,585 346 7,471 1,050 194 7,585 Total includes ventilation load for zonal systems. EnerovPro 5.1 by EnerovSoR User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 12 of 14 I C7 • • ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Chris Stahl-Casita Date 12/20/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 400.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT OF 400.0 X 0.0260 X 44 710.0 X 0.0690 X 44 7.0 X 0.7200 X 44 51.0 X 0.5800 X 44 perm = 77.0 X 0.7300 X 44 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room Page Total 1.064 X 400 X 9.00 )( 0.347 / 60 � X Area Ceiling Height ACH AT Btu/hr = 458 = 2,156 = 222 = 1,302 = 2,473 = = = = = = - = = = = - = = = = = = = = = = = - = 6,610 44 = 975 R-38 Roof Attic R-21 Wall Glass Block Double Non Metal Tinted Slab -On -Grade Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,585 EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-12-20708:33:32 ID: Page 13 of 14 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Chris Stahl-Casita 12/20/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature _ 112 °F Floor Area 400.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CL7D' Btu/hr R-38 Roof Attic (N) 400.0 X 0.0260 X 56.0 = 582 R-21 Wall (N) 234.0 X 0.0690 X 23.0 = 371 R-21 Wall (E) 143.0 X 0.0690 X 33.0 = 326 R-21 Wall (S) 198.0 X 0.0690 X 26.0 = 355 R-21 Wall 135.0 X 0.0690 X 33.0 = 307 X X = X X = x x X X = Page Total 1,942 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 1 (E) • 0.8 X 36.3 + 2.7 X e 71.3 = 222 Window 2 (E) 2.1 X 36.3 + 1.4 X 71.3 = 176 Window 3 (S) 6.0 X 31.3 + 0.0 X 31.4 = 188 Window 4 (S) 6.0 X 31.3 + 0.0 X 31.4 = 188 Window 5 (S) 24. 01 X 31.3 + 0.0 X 31.4 = 750 Window 6 (VV) 4.5 X 31.3 + 10.5 X1 62.7 = 799 X + )c _ x x = X, x = Page Total 2,323 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 820 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 x 0.87 x 21.89 X 34 = 686 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,471 Latent Gain Btu/hr Occupants 4.0 _ Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 21.89 X 0.00276 = 250 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,050 EnerqvPro 5.1 bv EnerovSoft User Number: 6712 RunCode: 2011-12-20708:33:32 /D: Pae 14 of 14