Loading...
BRES2015-0140LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 884767 Date: 5 117- Contractor:.AM^2r—A CGX�iabet / OWNER -BUILDER DECLARATION t I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to. construct the project. (Sec, 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATIOIi DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate o9 consent to self -insure for workers' compensation, as provided for by Section 3700 ofthe Labor Code, for the performance of the o for which this permit is issued. A�*ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My.workers' compensation insurance cz rrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of thework for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, i• I should become subject to the workers' compensation provisions of Section 370C of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant`. WARNING: FAILURE TO SECURE WORKERS' COMP•-NSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). !IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Bailding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed finder or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cita of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issLance of such permit, or cessation of work for 180 days will subject permit to cancellatiDn. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned property for inspection purposes. Date:02&/,22�1SSignature (Applicant or agent): 04 Ct �i a--- VOICE (760) 777-7125 78-495ALL TA C E MPICO 0O D LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 5/28/2015 Application Number: BRES2015-0140 Owner: Property Address: 56325 RIVIERA THOMPSON, TI MOTALAN APN: 762022001 PO BOX 370 Application Description: THOMPSON RESIDENCE REMODEL GIBSONS, BC VON 140 z s Property Zoning: LCI) Application Valuation: $12,000.00o Y 7N € u, Applicant: ROB PITCHFORD Contractor: ABARCA CONSTRUCION 77622 COUNTRY CLUB DR STE. 0 40490 YUCCA LANE Q PALM DESERT, CA 92211. BERMUDA DUNES, CA 92203 (760)832-3998` --------------------------------------------------------------------------------------------- LIC. No.: 884767 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 884767 Date: 5 117- Contractor:.AM^2r—A CGX�iabet / OWNER -BUILDER DECLARATION t I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to. construct the project. (Sec, 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATIOIi DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate o9 consent to self -insure for workers' compensation, as provided for by Section 3700 ofthe Labor Code, for the performance of the o for which this permit is issued. A�*ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My.workers' compensation insurance cz rrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of thework for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, i• I should become subject to the workers' compensation provisions of Section 370C of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant`. WARNING: FAILURE TO SECURE WORKERS' COMP•-NSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). !IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Bailding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed finder or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cita of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issLance of such permit, or cessation of work for 180 days will subject permit to cancellatiDn. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned property for inspection purposes. Date:02&/,22�1SSignature (Applicant or agent): 04 = PAID PAIDDATE t� F,�','DESCRIP.TION <» `f,ACCOUNTr FINANCIAL ,• 1 r -`' QTY' .r. AMOUNT. HOURLY PLAN CHECK - YES 101-0000-42600 1.25 $87.50 $0.00 , PAID BY ' METHOD ' " `,;a RECEIPT # s CHECK # CLTD BY Total Paid for BLDG CITY STAFF - PER HOUR: $87.50 $0.00 DESCRIPTION ACCOUNT." " CITY AMOUNT- - ;,PAID. _ PAID DATE+ BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY '. '-` METHOD _ RECEIPT # "CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY. - AMOUNT. '' PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0. $91.85 $0.00 ' '-PAID BY.- ; r,METHOD RECEIPT #, CHECK #, CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 �' ?• DESCRIPTION.' ?- ACCOUNT.; iQTY „AMOUNT PAID PAID DATE, GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT# ".: ,. CHECK # CLTD BY DESCRIPTION, .' _ ACCOUNTQTY AMOUNT- ;PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $24.17 $0.00 'PAID BY ' .' METHOD k,:' RECEIPT# .. CHECK# CLTD BY Total Paid for PLUMBING FEES: $36.26 .$0.00 .,DESCRIPTION ' •ACCOUNT, QTY AMOUNT " _ _' , PAID PAID DATE: SMI - RESIDENTIAL 101-0000-20308 0 $1.56 $0.00 ,'- PAID BY METHOD RECEIPT #'' w CHECK #„ CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $1.56 $0.00 :`DESCRIPTION r ': " ° ACCOUNT• �`, QTY. AMOUNT `` PAID,,,a PAID DATE DOOR/WINDOW, REPLACE FIRST 7 101-0000-42400 0 $60.91 $0.00 -PAID.BY RECEIPT #' `f =' CHECK # ' `CLTD BY DESCRIPTION' ACCOUNT;y ". QTY" .•• ,.,AMOUNT.0 ' _ -PAID," PAID, PAID DATE DOOR/WINDOW, REPLACE, FIRST 7 PC 101-0000-42600 0 $110.22 $0.00 ,PAID BY . , `- s METHOD '.' , '. , ;RECEIPT# CHECK #, CLTD BY Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $171.13 $0.00 TOTALS: $389.30 00 Description: THOMPSON RESIDENCE REMODEL Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 4/16/2015 PJU Approved: 5/27/2015 LUR Parcel No: 762022001 Site Address: 56325 RIVIERA LA QUINTA,CA 92253 Subdivision: TR 24801 Block: Lot: 8 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $12,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0. Details: POCKET SLIDING GLASS DOORS TO WEST & SOUTH WALLS OF FAMILY ROOM. TO INCLUDE 1 GAS LINE TO BBQ AREA. NO WATER OR WASTE LINE.WORK PER 2013 CALIFORNIA BUILDING CODE. Printed: Thursday, May 28, 2015 9:37:56 AM 1 of 4 C SYSTEMS ADDITIONAL CHRONOLOGY TYPE STAFF NAME ACTION DATE,°_ b `COMPLETION DATE: + ' } NOTES* Y f' -CHRONOLOGY , PLANS PROCESSED & SENT TO YOUNG FOR STRUC. PLAN NOTE KAY HENSEL 4/17/2015 4/17/2015 CHECK PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 4/24/2015 4/24/2015 STRUC APPROVABLE WITH ENG. STAMP & SIGNATURE RECEIVED PLAN CHECK PICKED UP STEPHANIE KHATAMI 5/4/2015 5/4/2015 PICKED UP BY ROB PITCHFORD PLAN CHECK SUBMITTAL PLANS ACTUALLY RECEIVED ON 4/16, BUT NOT PROCESSED KAY HENSEL 417/2015 4/17/2015 UNTIL 4/17 RFrFIVFrt PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 5/12/2015 5/12/2015 RECEIVED SENT TO PLAN CHECK KAY HENSEL 4/17/2015 4/17/2015 STRUC TO YOUNG - DUE 5/1/2015 CONSULTANT Printed: Thursday, May 28, 2015 9:37:56 AM 1 of 4 C SYSTEMS ` FINANCIAL INFORMATION LTD'jDESCRIPTION LEFT ROB PITCHFORD A MESSAGE. PLANS ARE READY TO BE TELEPHONE CALL PAID D, E EC LUIS URIBE 4/29/2.01S .4/29/201S $0.00 PICKED UP 1�011 CORRECTIONS. Total Paid for BLDG CITY STAFF - PER HOUR: $87.50 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 CALLED ROB PITCHFORD. PERMIT IS READY TO BE ISSUED. TELEPHONE CALL LUIS URIBE S/27/2015 Total Paid fo . rBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 S/27/2015 PERMIT ISSUANCE LEFT MESSAGE. 0 $91.85 $0.00 CONDITIONS CONTACTS GAS SYSTEM, 1-4 101-0000-42401 0 ADDRESS1z' $0.00 "P OUTLETS APPLICANT ROB PITCHFORD 77622 COUNTRY CLUB PALM DESERT CA 92211 GAS SYSTEM, 1-4 101-0000-42600 0 $24.17 $0.00 OUTLETS PC CONTRACTOR ABARCA CONSTRUCTION 40490 YUCCA LANE BERMUDA CA 92203 Total Paid forPLUMBING FEES: $36.26 $0.00 DUNES OWNER THOMPSON, TIMOTHY ALAN PO BOX 370 GIBSONS BC VON 1VO ` FINANCIAL INFORMATION LTD'jDESCRIPTION ­,�.ACCOUNT, CITY AMOUNT PAIDIT PAID D, E EC HOURLY PLAN CHECK - 101-0000-42600 1.25 $87.50 $0.00 YES Total Paid for BLDG CITY STAFF - PER HOUR: $87.50 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid fo . rBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Tntal Paid fnrPFRI%.AlT ISSUANCE: $91.85 $0.00 GAS SYSTEM, 1-4 101-0000-42401 0 $12.09 $0.00 OUTLETS GAS SYSTEM, 1-4 101-0000-42600 0 $24.17 $0.00 OUTLETS PC Total Paid forPLUMBING FEES: $36.26 $0.00 ` �i OF?Ytn'� --DESCRIPTION, z ACCOUNT ; 7 QTY ' AMOUNT t, : PAID "� PAID DATE ' RECEIPT # CHECK # METHOD, .• CLTD �. . REVIEWER'= SENT,DATE` _ .. DUE -'DATE' - 'y FINAL" BLD BY. SMI - RESIDENTIAL 101-0000-20308 0 $1.56 $0.00 APPROVED- ENG. STAMP & SIGN Total Paid forSTRONG MOTION INSTRUMENTATION SMI $1.56 $0.00 DOOR/WINDOW, 101-0000-42400 0 $60.91 $0.00 SAMUELS REPLACE FIRST 7 CONDITIONS CALCS NON-STRUCTURAL LUIS URIBE 4/17/2015 5/1/2015 4/29/2015 REVISIONS REQUIRED DOOR/WINDOW, 101-0000-42600 $110.22 $0.00 POCKET SLIDING GLASS DOORS TO WFST P. REPLACE, FIRST 7 PC. .0 SOUTH WALLS OF FAMILY ROOM. NON-STRUCTURAL LUIS URIBE 5/12/2015 5/26/2015 5/27/2015 Total Paid for WINDOW/SLIDING GLASS $171.13 $0.00 DOOR/FENESTRATION: TOTALS:00 SEQID INSPECTION TYPE,;;INSPECTOR `-- 'j.SCHIfb6LEb,j COMPLETED RESULT :'REMARKS i ". ' . NOTES INFORMATION 'L " " '> _ DATE ' '.DATE _ .• F , _ , Y ya � REVIEWER'= SENT,DATE` _ .. DUE -'DATE' - 'y FINAL" BLD - REMARKS NOTES PARENTPROJECTS BOND INFORMATION -DATE RETURNED REVIEWS 3 STATUS REVIEW TYPE' REVIEWER'= SENT,DATE` _ .. DUE -'DATE' - 'y KATHRYN APPROVED- ENG. STAMP & SIGN STRUCTURAL 4/17/2015 5/1/2015 4/23/2015 SAMUELS CONDITIONS CALCS NON-STRUCTURAL LUIS URIBE 4/17/2015 5/1/2015 4/29/2015 REVISIONS REQUIRED POCKET SLIDING GLASS DOORS TO WFST P. SOUTH WALLS OF FAMILY ROOM. NON-STRUCTURAL LUIS URIBE 5/12/2015 5/26/2015 5/27/2015 APPROVED NEED HOA LETTER TO INCLUDE 1 GAS LINE TO BBQ AREA. NO WATER OR WASTE LINE.WORK PER 2013 CALIFORNIA BUILDING CODE. - BOND INFORMATION Printed: Thursday, May 28, 2015 9:37:56 AM 3 of 4 &H4i SYSTEMS Bin # City of La Qriintd, Building &• Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012`7 Building Permit Application and Tracking Sheet Permit # �04 Project Address: S Owner's Name: �(}-o` A. P. Number: 7 2 0?j2 00 I Address: 5-r. —/zs Legal Description: / (1 r 24 � q/ Contractor: City, ST, Zip: (jS,(n;;'Ct-� Telephone: Address: Project Description: City, ST, Zip: , o 'PC 04ET f5;�— Dt VJC Telephone: P one: 1 �� State Lic. # : City Lic. M. Designer: j 'Pf Tc-(A.D Address:. City., ST, Zip:��cL,�i Telephone: 760 6 Z656 Construction Type: OccuP ;mcy: StateLic . #- Project tYPa (circle one):: New Add'n A,ter Repair Demo Name of Contact Person: 6�E J�,� ��.�..... Sq. Ft.: # Stories: #Units: Telephone # of Contact Person: 76.0 m© Estimated Value of Proj. � -- APPLICANT: DO NOT WRITE BELOW THIS LINE 11 Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Depo.:it Truss Calcs. Called Contact Person Plan Check Balarce Title 24 Calcs. Plans picked up J Construction Flood plain plan Plans resubmitted 5 v Mechanical Grading plan 2°" Review, ready for corrections/'issue Electrical Subcontaetor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'r' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees -prc� BUILDING ENERGY ANALYSIS REPORT 2D/S- 01t10 01 PROJECT:, Thompson Residence 56-325 Riviera Palm Desert, CA 92260 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club STE O Palm Desert, CA 92211 (760) 346-2856 Report Prepared by: • Jon Scott o FORL`p � _Scott Design and Title 24, In '�� 77-085 Michigan .Drive /pN Palm Desert, CA 92211 (760) 200-4780 Job Number: RECE.IVE APR 16 2015 Date: CITY OF LA QUINTA I COMMUNITY DEVELOPMENT 4/13/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. T-Iis program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. "' This program developed by EnergySoft, LLC -www.energysoft.com. • TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 11 y Form MF -1 R Mandatory Measures Summary 12 EnergyPro 6.5 by EnergySoft Job Number. ID: Jser Number. 6712 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xm1 CFF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Thompson Residence 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 02 Calculation Description Title 24 Analysis 03 Project Location 56-325 Riviera ENERGY USE SUMMARY 04 City Palm Desert 05 Standards Version Compliance 2015 06 Zip Code 92260 07 Compliance Manager Version BEMCmpMgr 2013-3c (710) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.5 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2947 15 A Number of Zones 1 16 Slab Area (FT2) 2947 17 Number of Stories 1 18 Addition Cond. Floor Area 0 01,91) Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 AQ Glazing Percentage (%) 21.0% AW COMPLIANCE RESULTS !� 01 Building Complies with Computer Performance Aft;"�' 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown%elow ENERGY USE SUMMARY 04 0!�; 06 07 08 Energy Use (kTDV/ft2-yr) Standard 4Des gn Proposed Design Compliance Margin Percent Improvement Space Heating ;0'7.90 5.94 1.96 24.8% Space Cooling �� 290.11 276.30 13.81 4.8% IAQ Ventilation40� 0.00 V� 8.38 0.00 8.85 0.00 0.00 0.0% 0.0% Water Heating Photovoltaic Offset "b — 0.00 0.00 — Compliance Energy Total W 306.39 290.62 15.77 5.1% .0 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-04012015-710 HERS Provider: Report Generated at: 2015-04-13 10:13:05 CERTIF OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015. Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. - Cathedral Ceiling CFF-01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: • -- None — HVAC Distribution System Verifications: • — None — Domestic Hot Water System Verifications: • --None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual 86 TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as ' mestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Ao 1* Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)" 348.30 ��� 332:53 15.77 4.5% includes calculated Appliances and Miscellaneous Energy Use (AMEU) . ; BUILDING - FEATURES INFORMATION 01 02 46� 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)t Number of Dwelling *AP Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Thompson Residence 2947 1 3 1 0 1 Cl`7 ZONE INFORMATION w 01 02 �� 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name ZoneNe HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 Residence Conditioned HVAC ez1 2947 14 DHW Sys 1 Registration Number: CA Building Energy Efficiency Stan dtaar'ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-04012015-710 HERS Provider: Report Generated at: 2015-04-13 10:13:05 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE NOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CFF -01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition N Wall Residence R-13 Wall 0 Right 2125 52.5 90 Existing No E Wall Residence R-13 Wall 90 Front 1250 157.2 90 Existing No S Wall Residence R-13 Wail 180 Left 2125 176 90 Existing No W Wall Residence R-13 Wall 270 Back 1250 225 90 Existing No Roof 2 Residence Existing Roof 2921 Existing No M, A OPAQUE SURFACES — Cathedral Ceilings 01 01 02 03 04 05 08 06 - 07 08 09 10 11 1 12 13 Statu Verified Existing Name Construction Typle® Roof Rise Roof Reflectance Roof Emittance Barrier — Roof s Framin Verified Orientatio Area Skyligh Roof Rise Roof Roof Reflectan Roof g Statu Existing Name Zone Type n (ft) Area ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor s Condifion Exigstin Roof Residence Existing Roof1 Right 26.1 �� 10 0 0 0 0.1 0.85 0.1 No ATTIC*�V 01 02 03 10 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Typle® Roof Rise Roof Reflectance Roof Emittance Barrier — Cool Roof s Condition Eng ti Attic Residence Attic RoofResidence je'qNated 0 0.1 0.85 No No No 0 IMP Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-04012015-710 HERS Provider: Report Generated at: 2015-04-13 10:13:05 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.kml CFIOF-01 Page 4 of 8 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 2x10 N Wall (Right -0) - -- 1 20.0 1.19 0.83 Insect Screen (default) Existing No ex 5x5 N Wall (Right -0) - - 1 25.0 1.19 0.83 Insect Screen (default) Existing No ex 2.5x3 N Wall (Right -0) - - 1 7.5 1.19 0.83 Insect Screen (default) Existing No ex 10x8 E Wall (Front -90) - - 1 80.0 1.19 0.83 Insect Screen (default) Existing No ex 1.5x5.5 E Wall (Front -90) - - 1 08.3 1.19 0.83 Insect Screen (default) Existing No ex 3.5x7 E Wall (Front -90) - -- 1 7 24.5 1.19 0.83 Insect Screen (default) Existing No ex 6x3 E Wall (Front -90) - - �i 18.0 1.19 0.83 Insect Screen (default) Existing No ex 1.5x5.5 2 E Wall (Front -90) -# &1 8.3 1.19 0.83 Insect Screen (default) Existing No ex 8x4 S Wall (Left -180) - -- 1 32.0 1.19 0.83 Insect Screen (default) Existing No ex 4x2 S Wall (Left -180) - - 1 8.0 1.19 0.83 Insect Screen (default) Existing No ex 4x2 2 S Wall (Left -180) - A� 1 8.0 1.19 0.83 Insect Screen (default) Existing No ex 8x4 2 S Wall (Left -180) - 1 32.0 1.19 0.83 Insect Screen (default) Existing No New 12x8 S Wall (Left -180) - �- 1 96.0 0.46 0.24, Insect Screen (default) New N/A ex 10x8 2 W Wall (Back -270) - - 1 80.0 1.19 0.83 Insect Screen (default) Existing No ex 10x2.5 W Wall (Back -270) - - 1 25.0 1.19 0.83 Insect Screen (default) Existing No New 15x8 W Wall (Back -270) �� - 1 120.0 0.46 0.24 Insect Screen (default) New N/A Skylight Roof (Right -0) �! - 1 10.0 0.71 0.60 None Existing No Skylight 2 Roof (Right -0) �`�- - 1 16.0 0.71 0.60 None Existing No Registration Number: C Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards' - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:05 CERTIF OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CF*F-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 1 296 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd Water Heater Heaters M 2x4 Top Chord of Roof Truss @ 24 Condition Roof Deck: Wood Siding/sheathing/decking Attic RoofResidence Attic Roofs Wood Framed Ceiling in. O.C. none '0.644 Roofing: Light Roof (Asphalt Shingle) DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Existing Roof attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Floor Joists: R-9.9 insul. k> Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x4 • Roof Deck. Wood Siding/sheathing/decking Existing Roofl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.061 Roofing: Light Roof (Asphalt Shingle) ®� • Inside Finish: Gypsum Board Cavity/Frame: R -13/2x4 Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. C. R 13 0.095 Siding/sheathing/decking r SLAB FLOORS �® 01 02 03 `� w_ 04 05 06 07 08 09 Name Zone Area#�ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Residence 1 42947 1 296 None 0.8 No Existing No — oLF BUILDING ENVELOPE- HERS VERIFICATION®� da. 01 02 03 04 Quality Insulation Installation (QII) Quality% Inr" siallation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa 05 06 Required R_ Not Required Not Required — W_ 7 WATER HEATING SYSTEMSnor' da. 01 02NO`� 03 04 05 06 07 08 Pv�r Solar - o� Number of Fraction Verified Existing Name System Type g a Distribution Type Water Heater Heaters M Status Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No N �� Registration Number: �® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stands - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:05 CERTIF OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JOD Project Name: Thompson Residence Calculation Date/Time: 10:1.2, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CF1tF-01 Page6of8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Comp ctDistribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a Af & Na - n/a n/a n/a 0i SPACE CONDITIONING SYSTEMS �� 01 02 03 04 Az 05 06 07 08 09 Multi -speed Heating System Cooling Sysifem System Type ® EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air c ditioning 10.42 12 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name �� Ducted System System Served Status Condition HVAC ext Other Heating and Heating Yes Cooling4N Yes Air Distribution HVAC Fan 2947 Existing No Cooling System Component 1 Compos, 1 System 1 1 HVAC - HEATING SYSTEMS 01 �� 02 03 Name � Type Efficiency w. Heating Component 1 �� CntrlFurnace - Fuel -fired central furnace 80 AFUE Am HVAC - COOLING SYSTEMS' 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type ® EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air c ditioning 10.42 12 No No N/A system Registration Number: CA Building Energy Efficiency. Stan daarrds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-04012015-710 HERS Provider: Report Generated at: 2015-04-13 10:13:05 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CF1OF-01 Page 7 of HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ FaXType IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 De Ault 0 Not Required ♦o� ♦ 40 ♦ V� Registration Number: �o Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 7 �- HERS Provider: Report Generated at: 2015-04-13 10:13:05 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD . Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thom pson-Pitchford-15.xm1 CFIOF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signatur<-A Jon d. Scott Jon Scott 6 Company: Signature Date: - Scott Design'and Title 24, Inc, 4/13/2015 Address: CEA/HERS Certification Identification (If applicable): - 77-085 Michigan Drive City/State ip: Palm Desert, CA 92211 Phone: (460) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT .w I certify the following under penalty of perjury, under the laws of the State of California: ��� 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for (Ae building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of oEompliance Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are con nt with th 'nformation ro d on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agenc*Vr approval this bu r i Responsible Designer Name: IC4 Re sible sign e' Robert A. Pitchford Company: �q v Da Robert A. Pitchford Design and Drafting Address: �� . License: 77-622 Country Club STE O IR® City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-2856 0 o®0 Registration Number: , � CA Building Energy Efficiency Standdaarrds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-04012015-710 N HERS Provider: Report Generated at: 2015-04-13 10:13:05 • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Thompson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family .m Existing+ Addition/Alteration Date, 4/13/2015 Project Address 56-325 Riviera Palm Desert California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,947 Addition 0 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 19 2,921 Existing Wall Wood Framed R 13 6,.139 Existing Door Opaque Door - no insulation 18 Existing Slab Unheated Slab -on -Grade - no insulation 2,947 Perim = 296' Existing Demising Wood Framed - no insulation 511 Existing FENESTRATION I Total Area: 6191 Glazing Percentage: 21.0%1New/Altered Average U -Factor: 0.46 Orientation Area f 2 U -Fac SHGC Overhang Sidefins Exterior Shades Status Skylight 10.0 0.710 0.60 none none None Existing Skylight 16.0 0.710 0.60 none none None Existing Right (N) 52.5 1.190 0.83 none none Bug Screen Existing Front (E) 139..1 1.190 0.83 none none Bug Screen Existing Left (S) 80.0 1.190 0.83 none none Bug Screen Existing Left (S) 96.0 0.460 0.24 none none Bug Screen New Rear (tM 105.0 1.190 0.83 none none Bug Screen Existing Rear (IM 120.0 0.460 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setbach Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC ex Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqvPro6.5bVEnerqVSoft User Number: 6712 Run Code: 2015-04-13T10:14:01 /D: Pae 11 of 15 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance aDDroach used. ExceDtions may annly. Review the resneetive Inde section fnr mnre infnrmntinn Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air lea<age. §I 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, o;rtified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of ' 10-11l(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § I I0.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include en the CF2R. § 110.8(1): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requ�•ements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive ca mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 :n 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. §I50.0(g)1: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. §I50.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in tte exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without fa•:ings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of ' 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six squaP inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control dtvice. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. §I50.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c). § 150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standares shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold .nater pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.0Q)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, Fiping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the rquirements of TABLE 120.3- A. § I50.0Q)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and ncn-crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 2013 Low -Rise Residential Mandatory Measures Summary §150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.0(i)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § I50.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(0): central.forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 4 2013 Low -Rise Residential Mandatory Measures Summary §I 10.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. § I50.0(k)I A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of ' 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)IC: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §I50.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § I50.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2. § I50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting.' §I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the- luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary 4 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical tine clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimurr_ provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150,0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, $130.0, § 130.2, § 130.4, § 140.7 and ' 14-1.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated b9 § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in §110.9, §130.0, 130.2, §130.4, §140.7 and '141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in §110.9, §130.0, §130.2, 130.4, §140.7 and §141.0. §I50.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 wats of power as determined according to §130.0(c). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 ' 130.0, § 130.1 ' 130.4 § 140.6 and ' 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce ,.he lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §I 10.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 6 through § 110.10 e . §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less rthan 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less =han 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. §I 10.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees 4nd 270 degrees of true north. §1 10.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mornted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zo-ie shall be located at least twice §I 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point o the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and ro-3f live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family res_dences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from 5110. 1 0(b) through § 110.10(c) shall be provided to the occupant. § 1 10.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 0 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CFIOF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Thompson Residence 02 Calculation Description Title 24 Analysis 03 This building incorporates one o�, more Special Feat—ures�own below �„ 0.%,_w Af AP ¢ 03 Project Location 56-325 Riviera t;'� � �"� � 3ft`" I? '� `�.,.s�' Tit � �...d >a•N.. f"'% 04 City Palm Desert 05 Standards Version Compliance 2015 06 Zip Code 92260 07 Compliance Manager Version BEMCmpMgr 2013-3c (710) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.5 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2947 15 Number of Zones 1 16 Slab Area (FT2) 2947 17 Number of Stories 1 -18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 21 Glazing Percentage (%) 21.0% COMPLIANCE RESULTS 01 Building Complies with,Computer Performa ce . 02 This building incorporates feaaturess`Ithat require fi ld-testl A141 �in g and/or.verificatio�by certife�H�ERS rat unde��he supervision of a CEC-approved HERS provider. 03 This building incorporates one o�, more Special Feat—ures�own below �„ 0.%,_w Af AP ¢ t;'� � �"� � 3ft`" I? '� `�.,.s�' Tit � �...d >a•N.. f"'% -. ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 7.90 5.94 1.96 24.8% Space Cooling 290.11 276.30 13.81 4.8% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 8.38 8.38 0.00 0.0% Photovoltaic Offset — 0.00 0.00 -- Compliance Energy Total306.39 290.62 15.77 5.1% Registration Number: 215-AO09535OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 4013 CF1*F-01 Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: • — None — HVAC Distribution System Verifications: • —None -- Domestic Hot Water System Verifications: • -- None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. IFa _. . Reference Enell rgy Used Energy.Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)` I `�� _`�348.30'U M a 332.53 " 15.77 4.5% ` includes calculated Appliances and Miscellaneous Energy Use (AMEU)`"'� " BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Thompson Residence 2947 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Residence Conditioned HVAC ext 2947 14 DHW Sys 1 Registration Number: 215-AO0953508-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xm1 C F1 OF -01 'Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition N Wall Residence R-13 Wall 0 Right 2125 52.5 90 Existing No E Wall Residence R-13 Wall 90 Front 1250 157.2 90 Existing No S Wall Residence R-13 Wall 180 Left 2125 176 90 Existing No W Wall Residence R-13 Wall 270 Back 1250 225 90 Existing No. Roof 2 Residence Existing Roof dlwl ` 2921 .....,. � . Existing No OPAQUE SURFACES - Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 13 Radiant Statu Verified Existing Name Roof Type Framin Roof Emittance Verified Cool Roof s Condition Orientatio Area Skylight Roof Rise Roof Roof Reflectan Roof g Statu Existing Name Zone . Type n (ft) Area (ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor s Condifion Roof Residence =_ ExistingRoof1 Ri ht o 9 01. 26 1 10 � 0 0 0 0.1 0.85 0.1 Existin No dlwl ` 1 .....,. � . 9 ATTIC ''.'. 01 02 )-1 F03R< 04 F t 05 406 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic Residence Attic RoofResidence Ventilated 0 0.1 0.85 No No Exi ti ng No PAP Registration Number: 215-AO09535OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CFIOF-01 Page 4 of 8 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 2x10 N Wall (Right -0) -- - 1 20.0 1.19 0.83 Insect Screen (default) Existing No ex 5x5 N Wall (Right -0) -- - 1 25.0 1.19 0.83 Insect Screen (default) Existing No ex 2.5x3 N Wall (Right -0) --- - 1 7.5 1.19 0.83 Insect Screen (default) Existing No ex 10x8 E Wall (Front -90) -- - 1 80.0 1.19 0.83 Insect Screen (default) Existing No ex 1.5x5.5 E Wall (Front -90) - - 1 8.3 1.19 0.83 Insect Screen (default) Existing No ex 3.5x7 E Wall (Front -90) -. - 1 24.5 1 1.19 0.83 Insect Screen (default) Existing No ex 6x3 E Wall (Front -90) - - 1 18.0 1.19 0.83 Insect Screen (default) Existing No ex 1.5x5.5 2 E Wall (Front -90) - - 1 8.3 1.19 0.83 Insect Screen (default) Existing. No ex 8x4 S Wall (Left -180) - - 1 32.0 1.19 0.83 Insect Screen (default) Existing No ex 42 S Wall (Left -180) - - 1 8.0 1.19 0.83 Insect Screen (default) Existing No ex 42 2 S Wall (Left -180) --- -- 1 8.0 1.19 0.83 Insect Screen (default) Existing No ex 8x4 2 S Wall (Left -180) - } F *tt�may- ',32.0 3� 9.1�9� 0�83s Insect Screen (default) Existing No New 12x8 S Wall (Left X80) - ' 1 -9fi Ow 10.46 '24 Insect Screen (default) New N/A ex 10x8 2 ►. a:-rr�xt�+. W Wall (Ba cyk-270) _-_ _ -_ _ 1 -` +.w: 80.0 -29.0 vv :.> 1.19 _ r; .''t 0.83 Insect Screen (default) Existing No ex 10x2.5 W Wall (Back -'270) - " --t' Mi k t L1�19 t 683 Insect Screen (default) Existing No New 15x8 W Wall (Back -270) - - 1 120.0 0.46 0.24 Insect Screen (default) New N/A Skylight Roof (Right -0) -- - 1 10.0 0.71 0.60 None Existing No Skylight 2 Roof (Right -0) - - 1 16.0 0.71 0.60 None Existing No DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door t Wall 16.1 O.GO Gxicting Nn Registration Number: 215-AO09535OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE NOOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13; 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CFIOF-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 07 08 09 Name Total Cavity Winter Design U Vk Perimete�rg f(ft) Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 2947 296 None 0.8 No Existing • Cavity / Frame: no insul. 12x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofResidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Existing Roof attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Floor Joists: R-9.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x4 • Roof Deck: Wood Siding/sheathing/decking Existing Roofl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.061 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking SLAB FLOORS 01 01 A02 1f1 1 03 0A4} 05fl' 06 07 08 09 Name Zone 1 ilk ir» = A(ft2) rea U Vk Perimete�rg f(ft) tf P 3t U V ,�may, 0 Edge InsuI R"value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Residence 2947 296 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 1 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No Registration Number: 215-AO09535OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 0013 Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CFIOF-01 Page 6 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control, Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10.42 12 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name _ Ducted ` ...: System System Served Status Condition HVAC ext Other Heating and 9 Heatin 9 Yes Coolin$ 9 g p Yes Air Distribution v _- i HVAC Fanx , 2947 Existing No Cooling System 9 y Com one�n;1 p p Com onen�Vl S stem 1 11 1__LXX 1.bmwa sk ar Ra W 'Q9"- fir �w M W I. W HVAC - HEATING SYSTEMS H F R P R 0 V I F 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10.42 12 No No N/A system Registration Number: 215-AO09535OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12 CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xmi Uf F-01 Page 7 of 8 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A , System 1 specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required i ! ' a T • - 'ERT!), Inc, HERS PRIOV1 Registration Number: 215-AO04535OB-000000000-0000 Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-04012015-710 a 4 HERS Provider: CaICERTS inc. Report Generated at: 2015-04-13 10:13:12 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE AOD Project Name: Thompson Residence Calculation Date/Time: 10:12, Mon, Apr 13, 2015 Calculation Description: Title 24 Analysis Input File Name: Thompson-Pitchford-15.xml CF1*F-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: %Nv,�cai- Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. Address: CEAMERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1: 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to„the enforcement eq.� r approvllwithjhigs, gilding permit application. Responsible Designer Name: te's ill L Rponsible Designer Sig atute: TS' Tim Scott ' a Company: H E Date Signed: Af Scott Design and Title 24, Inc. Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by WOWS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-AO09535OB-000000000-0000 Registration Date/Time: HERS Provider: " CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-13 10:13:12