Loading...
10-0501 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 10-00000501 Property Address: 56405 RIVIERA APN: 762-022-005- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 32367 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am ensed under provisions of Chapter 9 (commencing with Section 00 ofDivision3 of the s es an Pro sionals Code, and my License is in full force and effect. V ense (lames . B ' License N 684857 �r Date: . GD -O V60mractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city_or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or . improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: , LQPER111IT Owner: MCDANIEL, THOMAS 19601 MAYFIELD DR HUNTINGTON BEACH, CA 92648 ( Contractor: EDWARDS CONSTRUCTION 51455 DESERT CLUB DR LA QUINTA, CA 92253 (760)777-8202 Lic. No.: 684857 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/22/10 p U SEP 2n 2080 Irr- UN WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier GRANITE STATE Policy Number WC 555-61-55 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I ould come bject to the workers' compensation provisions of Section 3700 off the Labor de, sal i comply with th se provisions. Date: �O 1/Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all c. and oun y ordinances and state laws relating to b ' in onstr n, nd hereby au horize representatives If this c unt to enter u on the above-mentioned pro., ro y f r nsp ti u poses. u Date: /U Signature (Applicant or Agentl: Application Number . . . . . 10-00000501 Structure Information Construction'Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/LONG <=10 Other struct info . . . . . CODE EDITION 2007/08 ENERGY # BEDROOMS 1.00 GARAGE SQ FTG .00 -------------------------- 1ST FLOOR SQUARE FOOTAGE -------------=------------------------------------ 354.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee 304.00 Plan Check Fee 197.60 Issue Date . . . . Valuation 32367 Expiration Date 3/21/11 Qty Unit Charge Per Extension BASE FEE 252.00 8.00. 6.5000 -----------"---------------------------------------------------------------- THOU BLDG 25,001-50,000 52.00 , Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 31.23 Plan Check Fee 7.81 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/21/11 Qty Unit Charge Per Extension BASE FEE 15.00 354.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 12.39 192.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 3.84 Permit . . . MECHANICAL Additional desc... 1 Permit Fee 39.50 Plan Check Fee 9.88 Issue Date . . . Valuation . . . . 0 Expiration Date 3/21/11 Qty Unit Charge Per. Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 l.UU b.b000-EA ---------------------------------------------------------------------------- MECH VENT FAN 6.50 Permit . . . PLUMBING Additional desc . . LQPERMIT r LQPERA11T Application Number 10-00000501 Permit PLUMBING Permit Fee 55.50 Plan Check Fee 13.88 Issue Date . . Valuation . . . . 0 Expiration Date 3/21/11 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 6.0000 EA PLB FIXTURE 30.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 -----------------------------=---------------------------------------------- Special Notes and Comments CASITA (354), CART GARAGE (156), GARAGE (36SF) ADDITIONS TO EXISTING SFD.. TYPE V -B CONSTR. R-3 OCC. 2007 CODES /2008 ENERGY. ---------------------------------------------------- --------------------- Other Fees . ... . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 19.76 STRONG MOTION (SMI) - RES 3.24 Fee summary Charged Paid Credited Due Permit Fee Total 430.23 00 .00 430.23 Plan Check Total 229.17 .00 .00 229.17 Other Fee Total' 25.00 .00 .00 25.00 Grand Total 684.40 - .00 .00 684.40 LQPERA11T M. i B'° . {� C f City of La Quinta Building ex Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit � ���� \ �D Project Address: V ( Owner's Name: *4 -r>-K A. P. Number:�j Z C'% I�� Address: `7 6 QS (U Legal Description: M f Fk+- tq -T-IE7 GD ( Contractor. 'O�c ✓�C-,NCS` i City, ST, Zip: Telephone: Address: 5- Project Project Description: City, ST, Zip: Lk. ,-r- Telephone:'777 Cj ?-Oz- City Lic. M �� o� --�- State Lic. # : 0%-�^-`vpj-r— Designer:C C i SGF �;Q �M. Address: -77 -�j Zr2�- �� City, ST, Zip: % C::�/ If: % �iZ (� /4 'O L 4 Telephone: 6 7i� State Lic. #: Name of Contact Person: C Occupancy: ction Type: Occu cy: P ject type (circle one): New Add'n Alter Repair Demo Sq. Ft.: S� # Ston# Units: Telephone # of Contact Person: ,b Z� Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted (,::,(10 Item Amount Structural Calm Reviewed, ready corrections.) S Plan Check Deposit Taus Calcs. Called Contact Person 1 Plan Check Balance Energy Calcs. Plans Oicked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready fororrection ue tij Electrical Subcontactor List Called Contact Person %j ' Plumbing Grant Deed Plans picked upQ S.M.I. H.O.A. Approval Pians resubmitted Grading IN HOUSE:- ''' Review, ready for correction ssue 2Z Developer Impact Fee Planning Approval Called Contact Person Z A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees 10 Sd,u-v � dui Total Permit FPS�g s 7-47.q'11 Aii 9/i-11 aff- 9/3 J� At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 354 S.F. or $1,051.38 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/1st Bank - Ed Randall Check No. 95082 Name on the check Telephone 760-972-9607 . Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected /exemp d y aro c it rey Payment Recd $0.03 �" " ` $1,051.38 -' ove /Uadii, Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this wil e e to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on wh the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behElf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy -;Accounting CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road z4rncSlTlfS�o ¢ BERMUDA DUNES r Date 9/13/10 La Quinta, CA 92253 C/? • RANCHO MIRAGE d i6. INDIAN WELLS No. 30810 (760) 771-8515a' PALM DESERT ,y LA QUINTA, . . QINDIO 1�5 0 Owner M/M Thomas McDaniel APN # 762-022-005 Address 56-405 Riviera Jurisdiction La Quitta. City La Quinta Zip Permit # -Tract # No. of Units 1 Type Detached Guest House - Lot # No. Street S.F. Lot # No: Street S.F. Unit 1 56405 Riviera 354 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 354 S.F. or $1,051.38 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/1st Bank - Ed Randall Check No. 95082 Name on the check Telephone 760-972-9607 . Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected /exemp d y aro c it rey Payment Recd $0.03 �" " ` $1,051.38 -' ove /Uadii, Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this wil e e to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on wh the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behElf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy -;Accounting I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Mr. & Mrs. Tom McDaniel-Casita 56-405 Riviera La Quinta, CA 92253 Project Designer: 77-622 Country Club, Suite O Palm Desert, CA 92211 (760) 346-2856 �FGC �► CITY OF LA QUINTA BUILDING & SAFETY DEPT. w Report Prepared by:. APPROVED Jon Scott FOR CCNSTRUCTION i ` Scott Design and Title 24, I` cbATE 9 Z d 77-085 Michigan Drive BY Palm Desert, CA 92211' (760) 200-4780 IU AUG 2 0 2010 �-V LL Job Number: Date: 8/20/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energy§6ft.com. Energ Pro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-08-20713:16;03_ ID: • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Tom McDaniel-Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ AdditioniAlteration Date 8/20/2010 Project Address 56-405 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 354 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST E) Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. El Yes 0 No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 354 Radiant Barrier New Wall Wood Framed R-21 582 New Slab Unheated Slab -on -Grade None 354 Perim = 54' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 0.0 0.290 0.45 none none None New Right (NE) 7.3 0.720 0.39 none none Bug Screen New Front (SE) 46.6 0.400 0.39 none none Bug Screen New Left (SM 30.0 0.400 0.39 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-20T13:16:0 ID: Pa e 3 of 14 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5). CF -1 R Project Name Mr. & Mrs. Tom McDaniel-Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date $/20/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies used on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x12.24) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a .completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Amana ASXC 16024 includes credit for a 13.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC -1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC -1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing isrequired to verify that duct leakage meets the specified criteria. EnemyPro 5.1 by EnemySoft User Number. 6712 Run Code: 2010-08-20T13:16:0 ID: Page 4 of 14 • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) 1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Tom McDaniel-Casita ❑ Multi Family ❑ Existing+ Addition/Alteration $/20/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.75 1.76 1.99 Space Cooling. 90.44 80.78 9.66 Fans 18.60 26.70 -8.10 Domestic Hot Water 58.38 58.38 0.00 Pumps 0.00 0.00 0.00 Totals 171.16 167.61 3.55 Percent Better Than Standard: 2.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 198 47 Fuel Available at Site: Natural Gas (Suv) 135 30 Raised Floor Area: 0 (Nw) 198 0 Slab on Grade Area: 354 (NE) 135 7 Average Ceiling Height: 9.0 Roof 354 0 Fenestration Average U -Factor: 0.43 TOTAL: 84 Average SHGC: 0.39 Fenestration/CFA Ratio: 23.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the. building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 8202010 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 200-4780 Signed Date .The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address 77-622 Country Club, Suite O Name, Robert A. Pitchford, esign r City/State/Zip Palm Desert, CA 92211 Phone (760) 346-2856 Signed License # Date EnergyPro 5.1 by EnemySoft User Number. 6712 Run Code: 2010-08-20T13:16:0 ID:. Page 5 of 44 9 0 0 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Tom McDaniel-Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additbn/Alteration Date 1812012010 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix T e Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 354 0.026 R-38 0 0 New 4.2.1-A9 Casita Wall 128 0.069 R-21 45 90 New 4.3.1-A6 Casita Wall 151 0.069 R-21 135 90 New 4.3.1-A6 Casita Wall 105 0.069 R-21 225 90 New 4.3.1-A6 Casita Wall 198 0.069 R-21 315 90 New 4.3.1-A6 Casita Slab 296 0.730 None 0 180 New 4.4.7-A1 Casita Slab 58 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID T e Area U Factor SHGC Azm Status GlazingType Location/Comments 1 Skylight 0.0 0.290 NFRC 0.45 NFRC 0 New Bristol Skylight Casita 2 Window 7.3 0.720 NFRC 0.39 NFRC 45 New Glass Block Casita 3 Window 25.0 0.400 NFRC 0.39 NFRC 135 New Double Non Metal Tinted Casita 4 Window 21.6 0.400 NFRC 0.39 NFRC 135 New Double Non Metal Tinted Casita 5 Window 30.0 0.400 NFRC 0.39 NFRC 225 New Double Non Metal Tinted Casita (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Hbt Ri ht Fin Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-08-20T13:16:0 ID: Page 6 of 14 • Li L� CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. & Mrs. Tom McDaniel-Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additan/Alteration Date 1812012010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC -1 Casita 354 3,186 Totals 1 3541 0 01 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC -1 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER SetbacF New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Rlot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.59 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E 7 E W 2 Hot Water Piping Length ff o ¢ — System Name Pipe Len th Pipe Diameter Insul. Thick. Q HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5. 1 by EnerqySoft User Number: 6712 Run Code: 2010-08-20T13:16:0 ID: Page 7 of 14 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name r. & Mrs. Tom McDaniel-Casita Date 1 8/20/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory m=asures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Surrrnary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air.leaka e.' §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when s ecif'ed on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioratio:i. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. ,tquipped §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indbor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112°c . §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintermnce and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-08-20713:16:03 1D: Page 8 of 14 4 4 MANDATORY MEASURES SUMMARY: Residential (Page c" of 3 MF -1 R Project Name Date r. & Mrs. Tom McDaniel-Casita 8/20/2010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with maerials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation arca Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens stall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units arger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number.- 6712 Run Code: 2010-08-20713:16:03 ID: Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page,: of 3 MF -1 R Project Name Date Mr. & Mrs. Tom McDaniel-Casita 8/20/2010 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not recuired to be -controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact CC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that,disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the Ohotocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be. high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §1-: 9. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-08-20T13:16:03 ID: Page 10 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name r. & Mrs. Tom McDaniel-Casita Date 8/20/2010 System Name HVAC-1 Floor Area 354 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 345 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 44,000 7,185 710 118 6,349 Total Output Btuh 44,000 0 Output Btuh/s ft 124.3 519 451 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output Btuh 24,000 0 710 0 Total Output Tons 2.0 519 451 Total Output Btuh/s ft 67.8 Total Output s ft/Ton 177.0 1 8,222 1 7,252 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Amana ASXC16024 17,707 2,554 44,000 Alrflow cfm/s ft 2.26 Airflow cfm/Ton 400.0 Outside Air °i° 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 17,707 2,554 Aug 3 PM 44,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 800 cfm, 69 OF 69 OF 121 OF Heating Coil i:. 121 OF 00M M 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 76/62°F 55/54°F Outside Air LE 0 cfm Supply Fan Cooling Coil 800 ctm 76/62°F "I 1H 55 / 54 OF �.._..._.. _... _- . .. ....... ___._.... 46.7% j ROOM 3- 75/62°F EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-20713:16:03 ID: Page 11 of 14 • • • ROOM LOAD SUMMARY Project Name Mr. & Mrs. Tom McDaniel-Casita HVAC -1 354 1 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Casita Casita 1 345 7,185 710 345 , 7,185 710 1181 6,349 PAGE TOTAL TOTAL * 345 7,185 710 118 6,349 345 7,185 710 118 6,349 * Total includes ventilation load for zonal systems. EnergyPro 5.1 by Ene Soft , User Number., 6712. Run Code: 2010-08-20T13:16:0 ID: Pae 12 of 14 • r � U ROWHEATING PEAK LOADS Project Name Mr. & Mrs. Tom McDaniel-Casita Date 8/20/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 354.0 ft' Indoor Dry Bulb Tem erature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr = 405 = 1,767 = 231 = 1,348 = 1,734 = = = = = = = = = = = = = = = = = = = = = 5,486 44 = 863 R-38 Roof(R.38.2x 12.24) 354.0 X X 0.0260 44 R-21Wall (W.21.2x6.16) 582.1 0.0690 44 Glass Block 7.3 X X 0.7200 44 Double Non Metal Tinted 76.6 0.4000 44 Slab -On -Grade penm = 54.0 X X X X X X X X X 0.7300 44 X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interior surface to X 354 X Area Ceiling another room 9.00 X 0.347 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 6,349 Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2010-08-20T13:16:0 ID: Page 13 of 14 • • C. RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Tom McDaniel-Casita 8/20/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 354.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range.- 34 OF Opaque Surfaces Orientation Area U -Factor C -TD' Btu/hr R-38 Roof(R.38.2x12.24) (N) 354.0 X 0.0260 X 56.0 = 515 R-21Wall (W.21.2x6.16) (NE) 127.7 X 0.0690 x 29.0 = 256 R-21Wall (W21.2x6.16) (SE) 151.4 X 0.0690 X 31.0 = 324 R-21Wall (W.21.2x6.16) (SVI9 105.0 X 0.0690 X 31.0 = 225 R-21Wall (W.21.2x6.16) (NVIO 198.0 X 0.0690 X 30.2 = 413 X X = X X = X X = X X = Page Total 1,732 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 23.0 + 0.0 x 84.0 = 0 Window (NE) 0.0 X 28.9 + 7.3 X 41.4 = 302 Window (SE) 0.0 X 22.5 + 25.0 X 31.4 = 786 Window (SE) 0.0 X 22.5 + 21.6 X 31.4 = 679 Window (S K9 0.0 X 22.5 + 30.0 3 31.4 = 943 X + Z - x + w - x + 3 - x x - Page Total 2,711 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460. Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 x 0.89 . x 19.37 x 37 = 681 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,185 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 0.89 X 19.37 x 0.00376 = 310 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 710 EnemvPro 5. 1 by EnemySoft User Number: 6712 RunCode: 2010-08-20T13:16:0 ID: Pae 14 of 14