10-0501 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
10-00000501
Property Address:
56405 RIVIERA
APN:
762-022-005- - -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
32367
Applicant: Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION '
I hereby affirm under penalty of perjury that I am ensed under provisions of Chapter 9 (commencing with
Section 00 ofDivision3 of the s es an Pro sionals Code, and my License is in full force and effect.
V ense (lames . B ' License N 684857
�r Date: . GD -O V60mractor.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city_or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or .
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: ,
LQPER111IT
Owner:
MCDANIEL, THOMAS
19601 MAYFIELD DR
HUNTINGTON BEACH, CA 92648
(
Contractor:
EDWARDS CONSTRUCTION
51455 DESERT CLUB DR
LA QUINTA, CA 92253
(760)777-8202
Lic. No.: 684857
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/22/10
p U
SEP 2n 2080
Irr- UN
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier GRANITE STATE Policy Number WC 555-61-55
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I ould come bject to the workers' compensation provisions of Section
3700 off the Labor de, sal i comply with th se provisions.
Date: �O 1/Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
c. and oun y ordinances and state laws relating to b ' in onstr n, nd hereby au horize representatives
If this c unt to enter u on the above-mentioned pro.,
ro y f r nsp ti u poses.
u
Date: /U Signature (Applicant or Agentl:
Application Number . . . . . 10-00000501
Structure Information
Construction'Type . .
. . . TYPE V, UNPROTECTED
Occupancy Type . .
. . . DWELLG/LODGING/LONG <=10
Other struct info . .
. . . CODE EDITION 2007/08
ENERGY
# BEDROOMS
1.00
GARAGE SQ FTG
.00
--------------------------
1ST FLOOR SQUARE FOOTAGE
-------------=------------------------------------
354.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee
304.00 Plan Check Fee
197.60
Issue Date . . . .
Valuation
32367
Expiration Date
3/21/11
Qty Unit Charge
Per
Extension
BASE FEE
252.00
8.00. 6.5000
-----------"----------------------------------------------------------------
THOU BLDG 25,001-50,000
52.00 ,
Permit
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
31.23 Plan Check Fee
7.81
Issue Date . . . .
Valuation . . . .
0
Expiration Date
3/21/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
354.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
12.39
192.00 .0200
----------------------------------------------------------------------------
ELEC GARAGE OR NON-RESIDENTIAL
3.84
Permit . . .
MECHANICAL
Additional desc...
1
Permit Fee
39.50 Plan Check Fee
9.88
Issue Date . . .
Valuation . . . .
0
Expiration Date
3/21/11
Qty Unit Charge
Per.
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 9.0000
EA MECH B/C <=3HP/100K BTU
9.00
l.UU b.b000-EA
----------------------------------------------------------------------------
MECH VENT FAN
6.50
Permit . . . PLUMBING
Additional desc . .
LQPERMIT
r
LQPERA11T
Application Number 10-00000501
Permit PLUMBING
Permit Fee 55.50 Plan Check Fee
13.88
Issue Date . . Valuation . . .
. 0
Expiration Date 3/21/11
Qty Unit Charge Per
Extension
BASE FEE
15.00
5.00 6.0000 EA PLB FIXTURE
30.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
-----------------------------=----------------------------------------------
Special Notes and Comments
CASITA (354), CART GARAGE (156), GARAGE
(36SF) ADDITIONS TO EXISTING SFD.. TYPE
V -B CONSTR. R-3 OCC. 2007 CODES /2008
ENERGY.
---------------------------------------------------- ---------------------
Other Fees . ... . . . . BLDG STDS ADMIN (SB1473)
2.00
ENERGY REVIEW FEE
19.76
STRONG MOTION (SMI) - RES
3.24
Fee summary Charged Paid Credited
Due
Permit Fee Total 430.23 00 .00
430.23
Plan Check Total 229.17 .00 .00
229.17
Other Fee Total' 25.00 .00 .00
25.00
Grand Total 684.40 - .00 .00
684.40
LQPERA11T
M. i
B'° . {�
C
f
City of La Quinta
Building ex Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit � ����
\
�D
Project Address: V (
Owner's Name: *4 -r>-K
A. P. Number:�j Z C'% I��
Address: `7 6 QS (U
Legal Description: M f Fk+- tq -T-IE7 GD (
Contractor. 'O�c ✓�C-,NCS` i
City, ST, Zip:
Telephone:
Address: 5-
Project Project Description:
City, ST, Zip: Lk.
,-r-
Telephone:'777 Cj ?-Oz-
City Lic. M
�� o� --�-
State Lic. # :
0%-�^-`vpj-r—
Designer:C
C i SGF �;Q �M.
Address: -77 -�j Zr2�- ��
City, ST, Zip: % C::�/ If:
% �iZ (�
/4
'O L 4
Telephone: 6 7i�
State Lic. #:
Name of Contact Person:
C Occupancy:
ction Type: Occu cy:
P ject type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: S� # Ston# Units:
Telephone # of Contact Person: ,b Z�
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
(,::,(10
Item
Amount
Structural Calm
Reviewed, ready corrections.)
S
Plan Check Deposit
Taus Calcs.
Called Contact Person
1
Plan Check Balance
Energy Calcs.
Plans Oicked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready fororrection ue
tij
Electrical
Subcontactor List
Called Contact Person
%j '
Plumbing
Grant Deed
Plans picked upQ
S.M.I.
H.O.A. Approval
Pians resubmitted
Grading
IN HOUSE:-
''' Review, ready for correction ssue
2Z
Developer Impact Fee
Planning Approval
Called Contact Person
Z
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
10 Sd,u-v � dui
Total Permit FPS�g
s 7-47.q'11 Aii
9/i-11
aff-
9/3
J�
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.97 X 354 S.F. or $1,051.38 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/1st Bank - Ed Randall Check No. 95082
Name on the check Telephone 760-972-9607 .
Funding Residential
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exemp d y aro c it rey
Payment Recd $0.03 �" " `
$1,051.38 -' ove /Uadii,
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this wil e e to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on wh the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behElf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy -;Accounting
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
z4rncSlTlfS�o
¢ BERMUDA DUNES r
Date
9/13/10
La Quinta, CA 92253
C/? • RANCHO MIRAGE d
i6. INDIAN WELLS
No.
30810
(760) 771-8515a'
PALM DESERT ,y
LA QUINTA,
.
. QINDIO 1�5
0
Owner
M/M Thomas McDaniel
APN #
762-022-005
Address
56-405 Riviera
Jurisdiction
La Quitta.
City
La Quinta Zip
Permit #
-Tract #
No. of Units
1
Type
Detached Guest House -
Lot # No. Street
S.F. Lot # No:
Street S.F.
Unit 1
56405 Riviera
354 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.97 X 354 S.F. or $1,051.38 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/1st Bank - Ed Randall Check No. 95082
Name on the check Telephone 760-972-9607 .
Funding Residential
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exemp d y aro c it rey
Payment Recd $0.03 �" " `
$1,051.38 -' ove /Uadii,
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this wil e e to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on wh the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behElf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy -;Accounting
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Mr. & Mrs. Tom McDaniel-Casita
56-405 Riviera
La Quinta, CA 92253
Project Designer:
77-622 Country Club, Suite O
Palm Desert, CA 92211
(760) 346-2856 �FGC �►
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
w
Report Prepared by:. APPROVED
Jon Scott FOR CCNSTRUCTION
i
` Scott Design and Title 24, I` cbATE 9 Z d
77-085 Michigan Drive BY
Palm Desert, CA 92211'
(760) 200-4780
IU
AUG 2 0 2010 �-V
LL
Job Number:
Date:
8/20/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
• authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energy§6ft.com.
Energ Pro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-08-20713:16;03_ ID:
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs. Tom McDaniel-Casita
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ AdditioniAlteration
Date
8/20/2010
Project Address
56-405 Riviera La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
354
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
E) Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form.
El Yes 0 No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 354 Radiant Barrier New
Wall Wood Framed R-21 582 New
Slab Unheated Slab -on -Grade None 354 Perim = 54' New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Skylight 0.0 0.290 0.45 none none None New
Right (NE) 7.3 0.720 0.39 none none Bug Screen New
Front (SE) 46.6 0.400 0.39 none none Bug Screen New
Left (SM 30.0 0.400 0.39 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-20T13:16:0 ID:
Pa e 3 of 14
•
•
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5). CF -1 R
Project Name
Mr. & Mrs. Tom McDaniel-Casita
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
$/20/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies used on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof(R.38.2x12.24) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
.completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Amana ASXC 16024 includes credit for a 13.5 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System HVAC -1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC -1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing isrequired to verify that duct
leakage meets the specified criteria.
EnemyPro 5.1 by EnemySoft User Number. 6712 Run Code: 2010-08-20T13:16:0 ID: Page 4 of 14
•
•
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) 1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Mr. & Mrs. Tom McDaniel-Casita
❑ Multi Family ❑ Existing+ Addition/Alteration
$/20/2010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 3.75 1.76 1.99
Space Cooling. 90.44 80.78 9.66
Fans 18.60 26.70 -8.10
Domestic Hot Water 58.38 58.38 0.00
Pumps 0.00 0.00 0.00
Totals 171.16 167.61 3.55
Percent Better Than Standard: 2.1%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (SE) 198 47
Fuel Available at Site: Natural Gas (Suv) 135 30
Raised Floor Area: 0 (Nw) 198 0
Slab on Grade Area: 354 (NE) 135 7
Average Ceiling Height: 9.0 Roof 354 0
Fenestration Average U -Factor: 0.43 TOTAL: 84
Average SHGC: 0.39 Fenestration/CFA Ratio: 23.7%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the. building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
8202010
Address 77-085 Michigan Drive Name Jon Scott
City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 200-4780 Signed Date
.The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company
Address 77-622 Country Club, Suite O Name, Robert A. Pitchford, esign r
City/State/Zip Palm Desert, CA 92211 Phone (760) 346-2856 Signed License # Date
EnergyPro 5.1 by EnemySoft User Number. 6712 Run Code: 2010-08-20T13:16:0 ID:. Page 5 of 44
9
0
0
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. Tom McDaniel-Casita
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Additbn/Alteration
Date
1812012010
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
T e Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof 354 0.026 R-38
0 0 New 4.2.1-A9
Casita
Wall 128 0.069 R-21
45 90 New 4.3.1-A6
Casita
Wall 151 0.069 R-21
135 90 New 4.3.1-A6
Casita
Wall 105 0.069 R-21
225 90 New 4.3.1-A6
Casita
Wall 198 0.069 R-21
315 90 New 4.3.1-A6
Casita
Slab 296 0.730 None
0 180 New 4.4.7-A1
Casita
Slab 58 0.730 None
0 180 New 4.4.7-A1
Casita
FENESTRATION SURFACE DETAILS
ID T e Area U Factor SHGC
Azm Status GlazingType
Location/Comments
1 Skylight 0.0 0.290 NFRC 0.45 NFRC 0 New Bristol Skylight
Casita
2 Window 7.3 0.720 NFRC 0.39 NFRC 45 New Glass Block
Casita
3 Window 25.0 0.400 NFRC 0.39 NFRC 135 New Double Non Metal Tinted
Casita
4 Window 21.6 0.400 NFRC 0.39 NFRC 135 New Double Non Metal Tinted
Casita
5 Window 30.0 0.400 NFRC 0.39 NFRC 225 New Double Non Metal Tinted
Casita
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC H t Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len Hbt
Ri ht Fin
Dist Len H t
1 None 1.00
2 Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
5 Bug Screen 0.76
EnergyPro 5.1 by EnergySoft User Number. 6712
Run Code: 2010-08-20T13:16:0 ID:
Page 6 of 14
•
Li
L�
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Mr. & Mrs. Tom McDaniel-Casita
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Additan/Alteration
Date
1812012010
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existinq Altered Removed Volume
Year Built
HVAC -1 Casita
354
3,186
Totals 1 3541 0 01 0
HVAC SYSTEMS
System Name Ot . Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
HVAC -1 1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER SetbacF
New
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2
m
New
13
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Rlot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.59
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
7
E
W 2
Hot Water Piping Length
ff
o
¢ —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Q HP
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
EnemyPro 5. 1 by EnerqySoft User Number: 6712
Run Code: 2010-08-20T13:16:0 ID:
Page 7 of 14
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
r. & Mrs. Tom McDaniel-Casita
Date
1 8/20/2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory m=asures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Surrrnary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air.leaka e.'
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when s ecif'ed on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioratio:i.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
,tquipped
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indbor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112°c .
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinq sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintermnce and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-08-20713:16:03 1D: Page 8 of 14
4
4
MANDATORY MEASURES SUMMARY: Residential (Page c" of 3 MF -1 R
Project Name
Date
r. & Mrs. Tom McDaniel-Casita
8/20/2010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with maerials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation arca Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens stall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units arger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number.- 6712 Run Code: 2010-08-20713:16:03 ID: Page 9 of 14
MANDATORY MEASURES SUMMARY: Residential (Page,: of 3 MF -1 R
Project Name
Date
Mr. & Mrs. Tom McDaniel-Casita
8/20/2010
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not recuired to be -controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact CC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that,disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the Ohotocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be. high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of §1-: 9.
EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-08-20T13:16:03 ID: Page 10 of 14
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
r. & Mrs. Tom McDaniel-Casita
Date
8/20/2010
System Name
HVAC-1
Floor Area
354
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 345
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 44,000
7,185
710 118
6,349
Total Output Btuh 44,000
0
Output Btuh/s ft 124.3
519
451
Cooling System
0
0
Output per System 24,000
0
0 0
0
Total Output Btuh 24,000
0
710
0
Total Output Tons 2.0
519
451
Total Output Btuh/s ft 67.8
Total Output s ft/Ton 177.0
1 8,222
1 7,252
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Amana ASXC16024
17,707 2,554
44,000
Alrflow cfm/s ft 2.26
Airflow cfm/Ton 400.0
Outside Air °i°
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
17,707 2,554
Aug 3 PM
44,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 69 OF
Outside Air
0 cfm Supply Fan
800 cfm,
69 OF
69 OF 121 OF
Heating Coil
i:.
121 OF
00M
M
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/62°F 76/62°F 55/54°F
Outside Air LE
0 cfm Supply Fan Cooling Coil
800 ctm
76/62°F
"I 1H
55 / 54 OF
�.._..._.. _... _- . ..
....... ___._....
46.7% j ROOM
3-
75/62°F
EnergyPro5.1 by EnergySoft
User Number: 6712 RunCode: 2010-08-20713:16:03
ID: Page 11 of 14
•
•
•
ROOM LOAD SUMMARY
Project Name
Mr. & Mrs. Tom McDaniel-Casita
HVAC -1 354 1
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Casita Casita 1 345 7,185 710 345 , 7,185 710 1181 6,349
PAGE TOTAL
TOTAL *
345
7,185
710
118
6,349
345
7,185
710
118
6,349
* Total includes ventilation load for zonal systems.
EnergyPro 5.1 by Ene Soft , User Number., 6712. Run Code: 2010-08-20T13:16:0 ID: Pae 12 of 14
•
r �
U
ROWHEATING PEAK LOADS
Project Name
Mr. & Mrs. Tom McDaniel-Casita
Date
8/20/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 354.0 ft'
Indoor Dry Bulb Tem erature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
Btu/hr
= 405
= 1,767
= 231
= 1,348
= 1,734
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
5,486
44 = 863
R-38 Roof(R.38.2x 12.24)
354.0
X
X
0.0260
44
R-21Wall (W.21.2x6.16)
582.1
0.0690
44
Glass Block
7.3
X
X
0.7200
44
Double Non Metal Tinted
76.6
0.4000
44
Slab -On -Grade
penm = 54.0
X
X
X
X
X
X
X
X
X
0.7300
44
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 x 1.064
Schedule Air Sensible
Fraction
through an interior surface to
X 354 X
Area Ceiling
another room
9.00 X 0.347
Height ACH
Page Total
/60] X
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 6,349
Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2010-08-20T13:16:0 ID: Page 13 of 14
•
•
C.
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Mr. & Mrs. Tom McDaniel-Casita
8/20/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 354.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range.-
34 OF
Opaque Surfaces Orientation Area U -Factor
C -TD'
Btu/hr
R-38 Roof(R.38.2x12.24) (N) 354.0 X 0.0260
X
56.0 =
515
R-21Wall (W.21.2x6.16) (NE) 127.7 X 0.0690
x
29.0 =
256
R-21Wall (W21.2x6.16) (SE) 151.4 X 0.0690
X
31.0 =
324
R-21Wall (W.21.2x6.16) (SVI9 105.0 X 0.0690
X
31.0 =
225
R-21Wall (W.21.2x6.16) (NVIO 198.0 X 0.0690
X
30.2 =
413
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1,732
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
Skylight (N) 0.0 X 23.0 +
0.0
x 84.0
= 0
Window (NE) 0.0 X 28.9 +
7.3
X 41.4
= 302
Window (SE) 0.0 X 22.5 +
25.0
X 31.4
= 786
Window (SE) 0.0 X 22.5 +
21.6
X 31.4
= 679
Window (S K9 0.0 X 22.5 +
30.0
3 31.4
= 943
X +
Z
-
x +
w
-
x +
3
-
x
x
-
Page Total
2,711
Internal Gain
Btu/hr
Occupants 2.0 Occupants X 230
Btuh/occ.
=
460.
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 x 0.89 . x 19.37 x 37 =
681
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,185
Latent Gain
Btu/hr
Occupants 2.0 Occupants X 200
Btuh/occ.
=
400
Infiltration: 4,771 X 0.89 X 19.37 x 0.00376 =
310
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
710
EnemvPro 5. 1 by EnemySoft User Number: 6712 RunCode: 2010-08-20T13:16:0 ID:
Pae 14 of 14