0008-174 (AR)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp,
Date
557 B WC 1 03/3S6�/�c
ate Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier IVA TtJCMMINITY INS Policy No. )480372938
(This section need not be completed if the permit valuation is for $100.00 or less).
() I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of Calif orniaiand agree that if I should become
Tbej;Psh
fect to the workers' compensation/proulsrop9`of Section 3700 of tlrerLabor
ll� with comply with hse pr vdisiols.e Applicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application. s
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and'State laws relating to the building
construction, and hereby authorizer f5'resentatives of this City to enter upon
the:
he abo a mentioned property for i, pectlon purposes.
bi nature (Owner/Agent)r.`�,� Date'
a
1�1% BUILDING PERMIT PERMIT#
C) TE VALUATION LOT �8-1 74 TRACT
JOB SITE ", APN/J� j/�� �j� / �j�
ADDRESS N. 1; 7 & / —7 1D 3 W
OWNER
CONTRACTOR / DESIGNER / EN INEER
AARAWS VEE,1•iA R.
BOB EDWARDS COWMU•CTION
56.485 RISA
79-9201=07ADRIVE
Lk QU'dA TA CA 921^53
Z A QUINTA CA 9.2253
(760)775 7933 MIX 3212
USE OF PERMIT
1ZE.r`" 9DE?I~JT :+` L ADDTT109
ADDITION &_ ItL4b'JODLOL; TO 100VIWO SINOLF, FAN11'LY!CM- IDIENCE
ADDITION 443.00 S1=
,ES'1 IIA'1"KD COWr OF CONS'T1M1'JCs"1'ZON
22,42&90
FEE RUM"RY
PLAN CHECK FLE 101,000.439.318 $451,10
CONSTRUCTION FEE 101 X-IM419-000 $234.00
MWi"IC.AL .FEE 101-000-421.000 $45,00
ELLC TRICAL.I+ E 101-000-420-000 $50.50
PI.i3MBNO TEE 101-000-419.000 M.50
o.
to
S 1. :Ol4VIRUCTION AND Py'::laid" 00)
$509.10
b UZ3 PRE-P.A,1`D 1^F
$0100
` 9 2000 -
Au G 0 F��'.J►.M
1D9y Yn6 DUE J`TOW
$e .10
ti
♦ Y * f�
RECEIPT
DATE
BY i
D 7I E
INSPECTOR
—.' t
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
�'t'. MECHANICAL APPROVALS
Set Backs
• Underground Ducts
Forms & FootingsDucts
Slab Grade
Retum Air
Steel
Combustion Air
Roof Deck
Exhaust Fans =
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
I
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
,Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
I
Gas Piping
PLUMBING APP OVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp, Power Pole
Underground Conduit
Rough Wiring
Low Vottage Wiring
Fbdures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
r
Bin
City of La Quinta
-
Building 81: Safety Division
P.O. Box 1504
f
78-495 Calle Tampico
Pernaft #
La Quinta, CA 92253 ,
Building Permit Application and Tracking Sheet
�{
P,roje` ddre"ss:,, -4 V�.
�� � �
-� f .
Owner's Name: NTL
' 4
A. P. Number:Address:
%
Zip:
Legal Description:
JCity.ST,
\�j
Contractor:
Telephone:
Address "%� —� 2O '
(��g 1�" ``
j�ProJect Desrnption:-
C
t���
Cin'.ST'Zip
ho _7 g 3
rf�vt`tC-
S
�iT-r T
Tele P ne:
rStatic• l`z S
City Lic'. #:
Arch.. Erier.. Designer:
Address:
City. ST. Zip:.
ho ne: _
Telephone:
P
on T Occupancy.
C Type:
Construction coYP
State Lic.
Project tYPe (circle one): N Addo Alterr Repair r Dem
ZS9• Ft.: %
# Stories:
1t Units:
Nameof Contact Person:
Telephone = of contact Person:%S` 3
Estimated Value of Project:
....... ................
................................................
..::..:..:.:::..;::::......:::.::::::.:::.i:.i)i:..:
:..:•.i:.::i:.:.iii:•i;:.::.:;.i.ii:.i:.: ;::•i:.i:.;:.):<;.ii:.ii
::.::::::::................................ ::::::::::::::::::::::::.:..
................................:..::::::•::::::::::.::..:..
::: .: :..:>:::..:::?:.i:•;:;•;::::•::::::::::::::::::.:....?.:?.;ii):;:.::i)i::..::ii:.i:. is<• ..
�.i : ..i ::: :.: ? .. ;>:::illll.;i;:.;:z•):•i:•i:.i:::i:;•ii:.;:•}:•i:;.;:.i;;:;•::?.;i;;?;:.;i:;:.;:.;:•:iii:::>:,.:.i:•i>':>.:;;:`'
..... ; :................
PUCAI�iT:.:.:Do:?NO. ?. NAI E:.B£Lfl1K;:TH. s:::.::::: is?..;•.)::;• .......:.. :::,..:.:,::..::...,.:::::::....:..::
q.
11
.;:?':`<;.>r::;;>::::i.s::::is::�>�>:'::;'::i:::«i:'.'lF�>t::e:<g::<:�:;di:,:i:>i:::>i :i<>>:;;?>R:.<:e:;m:;:.:;:.):.:;.i::::•:
::.::::.?:?>.<•>:::;<�:.::<:i5i::i�:>::i.�::;:S:.z:Fz:<::%:::�:>::::�::>::::::>:`:'::::>::::>:�::�::;::T;.:.B:??;i:+;;
ii:}.:.:;is.a.:.i:.i:.;:%�::`>•i><::<:;:::::<:::;::»;>:>::;:»;:;r::::::>>::::>?i:":�:::�::<�::::
:::4:::»::
.ii::.i:
'§
,.... .
_........Submirtal..... •:.;ii'•k
:. •::::::......::.:::.
:.::.:::::.:::....::.:::::::............................
......::...................... .. ............
.. .....:.:..
.. ..:...:....
Ylaa:.. leck'.f ........ .:i:s':::.'
::::: :.i:a'::;�::.:::. is
i:.:.item::::>::>:<:>::>::::::>>::::>:>:>::::::»:<�:::::
'
:a: i:. �::::::::::::::•::::::: t;•::.i:•i:•:?+•;y.; ::iii•);;,.i.:.:i:.�:::::::�i):;;i:;
.......::.....
>:::€:?:>:?.::1me `
.. .......... ................ ::. ..................
.....:::........::.::::::..:.......................:..........::::::::..::
.i:•:;.:..:.:.;:.i:•i;:.;:.;.;i:::.:::::::.i;:?•i;>}:::.;:
ctnral:Gi•)..::::::::::.::::..::::..:::;::.:::;.;:.):;:.i:.i:.i.i:.i:.:.i:.i:.iiii.::::)):.:............::....
......... :. ................:::. �:.�
;.Rsvxwea,..read.?.ior:eoireetioa;
.....::.:::::
::.:.::.:
.. • ..........
::::.:::.:..
....::•. �::::..::.:. ,may_; .
...............:....... .
•:
Q; eck:De
Trus:..................................
:::.t ::.:....:::::::.
raen.::::•::::::•:::::::
.. ........................:.:p1aa:<3eck
..
..::.:.::::::.i'•ii:•}.;.>:?•ii::;.:•::;>:?+.i:.ii•.}i:.::.}ii:<•.:.
Trtk.24 Gla.:ii.i:.::.:;;:.. •}: •::::.:.....
.. .:::::;iii:i:}:Si?i::?;ii:::i:;::::..:'::i:;:i;•i:i:::'''
.:Pleas; ,eked....::::::::::.:::._:::::..::::::::;::::<.:;:;.,
.......•.: ........
;..:.::.::;::.:::<::::.:;:.);:::::.):::;:?;?;?}:.::.:;.ii:??;•):<•
W. - .:...
•
'C6LS:f tlt..... ::;.):•::):.:.::.:
::;.::<:»?::»:t:>:<:::::>::<:»>::ii:;<:••ii:.i:.ii:•»:.):;?.}:.iii:::.
aii6" 'rte b
:>:::>:::;>::�:::':::::)»'::;�:
.<> .
....
..'S.chooE:�'sest>><:>:<i;:�>:�:>:»::Rcy�c�fsdrfgdxinoiutp�S
.......... ......................
.:•v:::::::??)ii)i ):.}: i:'({:iii:ti:r: ))})))): i:.ii?))}:vfiiiiiii::
.. .. .. .:::::::::::•:.: �. ;?•::::•::::::•:::.� ::::.i'+?;•i>::::::::
:•. .:.y ...:.. .::....... .:. ..:;: ..::.: •?iii iii:.i)})): ii:
.:. .:::::: .. �:.i•o-:.;
:
::..:...:.
... •:..:.::.iii:.::.;•:.�:::::::.:::::::::::;•iii'.;i;;...
:}:i:t:i::i:::::i ). i):::::.. ....
.::::::. .::. �:.:.�: .. {....;
.::......::.::�..
>•.;::;•i}ii:.;i::::::.}: ::::::::::::::.::::;iii•?.)::.:::::.
.. �.............::............ ..... ... .
..F.Iteiii....._:..i::•)r.:?n::•:::::::::::.::.::. ::)"::::: iE'rJ..r":::.'':,
.:...
,.; . -. .
. ... ....... .........................
ubcentaftB/':#?•i:.i:.:::.i>:;?.i:.:.:???•:•>:•.?•;:•::•:.:.�
:::•::.::�
...:....:....:.::::.....:..:...:......:.:. ...: ..
to t:... :>::::..:::.:::::
:�R�.::.: �a::•i:•i:.i:.i::;•i•i.:.;:;:
..
• .....:... ,..::.:..:..:....
::::.:....:..•..:..:..:..
:.. M'
LhtE.>iii)iii:.:.::;.;:::::::•:?::::. ... ...:::.
..................................... .
...,;...
...
'. �........ .. )):•} }i:•)))i?:ii:>iY�iii: •iiiiii;i}i::iiiiii
.:::::::.•::..::............:......::.......::.:..:Ds:sf:..
•::::.ii>•::::.:::::
............
�:
....:?•:: )))}}i:::tri:?•::v:. :
ii�:::::.::::.....................
rmiti+aae:<c><::<:ii::ii:»::»:<z:i:•::.ii:.;:?::ii?::<).?.<::.?•i:.::;•i:.:•i.,.:
v: )i:•: )i:4): )):: :J:i ii:Jiiii
:::i.: iii:}))}'•v:•Y �
"h iJY:Y�
:i ::::::::::::.::::. . .. : is??:;??•}iii:.;:;:;: i::> ;::.ii>....
j: �' ::::::; :::??^:;`+•i:?•}iv::v::.. .....:........ ...nvf.
::...:::w:::::::� :v:.:.........?i}.
.:::�oetraetor.:intu:.�::•:.
:.Y. � iii;:•i � •:� :•i;iiiiii:;i:<i;:; �y�
.Y..
. ?:+•.:::::::::nom .:i:i•iiii:'^)i):??!� :ii
.. .. .......... :...:v::::v:::::::.
... .. .......... ................. ...................
iii)}: �:�iiii: )ii
............ ..
.: ...:.........::::n y::::::: p':::::: •.
.;;?i:};i:;}():?<i???4:?•: ^i)i):^:•: ii:^:??•)
.... .....:::w::::::.:::.:::::::::::::::::::.:.)'v);: i:•i}):•)
.:::::.v:::.:.�:::::::.v.:::
:::v.v: n•.)'+:.v:::nw::::::'
Jii:"•EWA.?iiii$+r• i
.: .. ?,Y.v•vyy:.. QL� +. :. M.:: rrr.!
IN
?: ........................... r.............. � q:?.: nv::xv: ^"
.
:•::::::::::::::::: ::
.. Row
r::::?•::;•:?•i:.)::..::::::::::::.:.�::•::::..:::::.,.::
M.
.::::•:::?.ii)i:::•i::•:•i:•ii
?•>:?:•i i:•i:•i: ii::•;);::: ):a;::
:: ?... ..ar .
:::...:................ .
MOM
....
stb %]ct..
..................................................:•........
......... ........... ................... ..............
:..
.............................................................
................... r....
.:::......:........
............................
..................................
Y
... ni}Y?:•r..i:L}:^}}:.}:•i:
A.......................................
OWN
:..
...
...... ....... ......:
... .. n.... •: ::::::.v.
•.::::.::::nv::::nv?v ....... .: ?::•
.. .. .. .. .. ...... .......... ........ .....
n..........
v ..............
..............
.........::w::::::::::.::v:: •n n.::::::::::::.v:::::: v):v))
nv.v::nvnv:.
.................... ... .............. ...................
:w::::::::. �:::.)))):•i)}:•})'
....:w::::.i w:::: w:::::"
:..:.
r:.:•!•i••i
v........... i...... ./ .r ...;:::.,.; .: v.:.. •; ...
i:•Y:}:•})i'')::•: • ...... ........... r ::: i.;: x f•: .v ii �iiiiiYvrsYrY?ii: {+::
.:: nv::::.v::: :^}::: �:ih.?:.::::::.t!?y?vn•):.
.
..... .............................................:::::::::::::::::.........................:::.
;�.�VIe ;.: ..::::: x: :::..:.i'.:.i)'v}i)i w::::;}})X)ii}i}
...........:.....
:•:::.v.v:::.v; }•... :::: w:::.v::::::::::::::: n•...
...............:.:: w:::::.
.:::::.:::•; ;:.: ..:::.
.:::: nv;::::: �.: �..::. .. :i?^•:)}iii:^i},r.;::•)}i
.f ••}:.iii:• >•:?•}:•i::ri:
+...........::::: '?J): iiia': i:•iiiii�iii:i �:
.::::::: n...• .n:•.Y;?Jv.:::.i
P....:::.::.:....::,.:.:....._
v.
.:ii'•ii:i:iiii}i)iii:ii::ii:ii::j?�ii::;i:
t..f l;:?rlv $
.vrh:+?:: :.:.:::::•: ::.:::: •.
.............
:::..:.:...: �:•:?:::...........
Ag.•;approval:: n�i:in•;i.;. .. ....,...............
.............
.. ::::::::::::::
Datc.affinit.loapec..
...
•::.;:::.::•}:.:.::::).i:;•i:.i:::::"ICofii!efmlE:"ebt?»>::<?
:..::}:?;•ii ': r::::::: .n.... ::.: •..:: krar „f.:'+.}.:is:�i:�:�j�F:G:•`.::%%:r:::4•; f
s ?. %::.
Desert Sands Unified School District
47-950 Dune Palms Road
Notice: La Quinta, CA 92253•
Document Cannot Be Duplicated,
760-771-8515
CERTIFICATE OF COMPLIANCE
Date 8/7/00 APN # 761-461-036 -
No. 20853 Jurisdiction La Quinta
Owner NameMr• & Mrs. Steve Haber Permit #
No. 56-485 Street Riviera Log #
City La Quinta Zip- 92253 Study Area
Tract # Lot # Square Footage 413
Type of Development . Residential Addition No. of Units
Comments
bedroom expansion-
At
xpansion
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It
has been determined the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This -certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of
0.00 X 413 or $ 0.00 the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued
Fees Paid By N/A Telephone 775-7933
Name on the check
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Ellen Patino Exempt^ 30.00
P.
Check No. ,N/A
Signature
IOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1998) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified
above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
ollect them on the Disldct('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant , Copy - Applicant/Receipt Copy - Accounting
4
April 21, 2000 -
PGA -,;Ni'a N RESIDEN-FiAL ASSOCIATION,
F.U. BUX.EZUT LA QUIN.IA, 4..A 911-33
(760) 776-5100 FAX (760) 776-511.1
Mr. & Mrs. Steve Habcr
9249 S Broadway, N422
116--5-6-vu
-?kw.)hft.er.m.nd and Lands=inr CbAn= -
Room Addition
Dear Mr. & Mts.'Haber:
.nc r�.'PA ho flip 6'.ft1WdnMjniUm
Afrh4e.chm.1 rAmcn-iftee ati AcHl 19. 2(W and wiSbeS to advise that V611Y VI=s have been aPPFVVed.a5
submitted.
Ficase conwi kapAaW VIIiarCW',.s,tjPCTVA-sDr J -Gr Va*-LV;*Y' U-aM,C-IU, LIS 3-C: V?W' , aL, -1 U'IGI-J^7 -7--1 GO
'Ful'Acr, il= . . FU
-' - - - - - - ��Ath 1!:-te-
�W. IFUIVI 416r U-11
4 -M -1
-
the. In.mtm...m-in
i.e.,.Abmbs-.trcm flower
a— rI----
-ic lb—Teq---,.bi!ilvof Llt 00111MCWT, The 191CSCaPing must bebrought
back to its originAl
condidon'when the proj= is compleAedL
A As kjysjj tjY it* JUCIUMC71-
f_0A=1-g— are gMa Mt- GWY SE& Uzum
if hPVC pftr aues6ons. 01 fte
at jiml615 i0o... W. 10:
11
liftr1rcly,
far the rmdaimimiom-
ACIP
cQ,
klriie t'-fle.,
-t-t- TOTAL -PAGE-01 *4
1,60 141,41 0 5 e. JzqwH -W 9AVaS W6z;4,0 00 -64 --jalu
TITLE 24 REPORT
Title 24 Report for:
Haber Residence (Existing)
56-485 Riviera
La Qu i nta, CA 92253
Project Designer:
Robert A. Pitchford
41-625 Eclectic Ste. A-2
Palm Desert, CA 92260
(760) 346-2856 -
Report Prepared By:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
(760) 346-0855
Job Number:
901.13A
Date:
7/21/00
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 2.1 By EnergySoft Job Number.: 901.13A User Number: 3665 1
0
0
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Haber Residence (Existing) 7/21/00
ro�ec i e a e
56-485 Riviera La Quinta
vroject Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
ocumen a ion Author i a ep one
Computer Performance 15
Building ermi
Plan Check I Date
Helcl Uhecka e
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 2,763 ft2
Total Conditioned Slab Area: 2,763 ft2
Building Type:
(check one or more)
® Single Family Detached (8FD) ❑ Addition Alone
❑ Single Family Attached (SFA) ® Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (Nodbeast) 45 deg Floor Construction Type: 0 Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
Component
Type
Frame
Type
Const.
Assembly
U -Value
Location/Comments
(attic, garage, typical, etc.)
R-30 Roof (R.30.2x12.16)
Wood
0.034
Exterior Roof
R-19 Wall (W.19.2x6.16)
Wood
0.065
Exterior Wall
Solid Wood Door
None
0.387
Exterior Door
Slab On Grade
n1a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
FENESTRATION
Shadinq Devices
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
(SF)
U -Value
SHGC
(roller blind, etc.)
(shadescreen, etc.)
Yes / No
Yes
/ No
Skylight
16.0
0.94
0.60
None
None
❑
Q
❑
Q
Front
(Northeast)
80.0
0.85
0.70
Drapery
Bug Screen
x❑
❑
❑
0
Front
(Northeast)
37.5
0.72
0.73
Drapery
Bug Screen
❑
X❑
❑
0
Front
(Northeast)
14.1
0.72
0.73
Drapery
Bug Screen
0
❑
❑
0
Left
(Southeast)
80.0
0.87
0.70
Drapery
Bug Screen
❑
X❑
❑
X❑
Left
(Southeast)
80.0
0.85
0.70
Drapery
Bug Screen
❑
X❑
❑X❑
Left
(Southeast)
25.0
0.72
0.73
Drapery
Bug Screen
0
❑
❑
0
Left
(Southeast)
48.0
0.72
0.73
Drapery
Bug Screen
❑
X❑
❑
X❑
Left
(Southeast)
48.0
0.85
0.70
Drapery
Bug Screen
®
❑
❑
Rear
(Southwest)
80.0
0.85
0.70
Drapery
Bug Screen
❑
0
❑
0
Rear
(Southwest)
25.0
0.72
0.73
Drapery
Bug Screen
X❑
❑
❑X❑
Rear
(Southwest)
82.0
0.72
0.73
Drapery
Bug Screen
❑
®
❑
]
Run Initiation
Time: 07/21/00 13:17:00
Run Code: 964210620
EnergyPro 2.1 By Energysoft
User Number: 3666
Job Number: 901.13A
Page:3 of 24
0
0
0
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Haber Residence (Existing) 7/21/00
rojec i e a e
56-485 Riviera La Quinta
vrojecc Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
uocumentation Author i a ep one
Computer Performance 15
Building ermi
Plan Check / Date
iela (;heCK I Uate
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 2,763 fl?
Total Conditioned Slab Area: 2,763 ft2
Building Type:
(check one or more)
® Single Family Detached (SFD) ❑ Addition Alone
❑ Single Family Attached (SFA) ® Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (Nofteast) 45 deg Floor Construction Type: a Slab Floor
Number of Dwelling Units: 1.00
Number of Stories:
BUILDING SHELL INSULATION
Const.
Component Frame Assembly
Type Type U -Value
FENESTRATION
❑ Raised Floor
Location/Comments
(attic, garage, typical, etc.)
Shading Devices
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
(SF)
U -Value SHGC
(roller blind, etc.)
(shadescreen, etc.)
Yes / No
Yes / No
Rear
(Southwest) 48.0
0.85 0.70
Drapery
Bug Screen
X❑
❑
❑ x❑
Right
(Northwest) 2.0
0.72 0.88
Drapery
Bug Screen
❑
x❑
❑ x❑
Right
(Northwest) 25.0
0.72 0.73
Drapery
Bug Screen
❑
x❑
❑ x❑
Right
(Northwest) 7.5
0.87 0.70
Drapery
Bug Screen
❑
X❑
❑ x❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
Run Initiation Time: 07/21/00 13:17:00
Run Code: 964210620
EnergyPro 2.1 By Energysoft
User Number: 3665
Job Number: 901.13A
Page:4 of 24
40
\J
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Haber Residence (Existing) 7/21/00
rojec i e Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
Central Furnace 78% AFUE Ducts in Attic 4.2 Setback Existing Heat/Cool Units
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 10.0 SEER Ducts in Attic 4.2 Setback Existing Heat/Cool Units
WATER HEATING SYSTEMS
Rated 1 Tank Energy Facts 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value
Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.53 n/a 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: Robert A. Pitchford
Address: 41-625 Eclectic Ste. A-2
Palm DesertCA 9 260
Telephone: (7 46-285
Lic. #:
�/ QJ
ature ate)
Efiforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Name:
Title/Firm
Address:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
Telephon : (760) 6-0855
(signature) I (da )
signature stamp date
Run Initiation Time: 07/21/00 13:17:00 Run Code: 964210620
EnergyPro 2.1 By EnergySoft User NumIJW Job Number: 901.13A Page:5 of 24
Certificate of Compliance: Residential (Addendum) CF -1 R
Haber Residence (Existing) 7/21/00
- Project Title Date
•
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
s- - &- QY M -y VI 1.116 JV -01 J-11 0-11 OIIU YVVYIIICIIWUVII ODUIIIIIICU.
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanke .
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2072 sgft Exposed Slab Floor, 3.50" thick at Existing House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 691 sqft Covered Slab Floor, 3.50" thick at Existing House
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
..�w..:.A..� TL.. u0ne ����- �..�♦ J��..���a �L� L:�IJ ..� :L:��a.__ __J J._____�._ a__�..-_ _LaL___ _____.___ __ _
pi Vvlu61. I lie "I M.X 10%01 IIIUOI docu 1 em Me IICIU VCIIIII: ILMI 411U U1C1911VO111: lCJ11111J U1 U1COC measures On a iorrU lir-oR. an ield
RunInitiation Time: un Code: 964210620 1
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:6 of 24
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties
as binding minimum component specifications.
IDESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. I DESIGNER IENFORCEMENT
naing tnvelope measures
'§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
§ 150(b): Loose fill insulation manufacturer's labeled R -value.
'§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls).
'§ 150(d): Minimum R-13 raised floor insulation in wood framed floors.
§ 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch.
§118: Insulation specified or installed meets quality standards. Indicate type and form.
§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.
• ® §150(i): Setback thermostat on all applicable heating and/or cooling systems.
® §1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined internal/external insulation, piping between heat source and tank insulated.
3. Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R4 or greater), buried or exposed
piping in recirculating sections of hot water systems, cooling system piping below 55 deg F.
§150(m): Ducts and Fans
1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections
601603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be
sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181,
UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m).
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated
dampers.
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating.
2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light.
ghting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
I® 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed
ceiling are IC (insulation cover) approved.
IEnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:7 of 24 1
Computer Method Summary (Part 1 of 3) C -2R
Haber Residence (Existing) 7/21/00
�Project Tie Date
56-485 Riviera La Quinta
vroject Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
Documentation Author i a ep one
Computer Performance 15
Co hance Melmod --a e or om u er
Building ermi
Plan Checliluate
V g p ima a one ie ec a e
Source Energy Use Standard Proposed Compliance
(kBtu/sf-yr) Design Design Margin
Space Heating
4.21
3.07
1.14
0
Space Cooling
40.27
66.55
-26.28
90
Domestic Hot Water
10.31
10.22
0.09
90
Totals
54.79
79.84
-25.04
90
Wall
BUILL)ING
DUE5
NOT COMPLY
90
GENERAL INFORMATION
Conditioned Floor Area:
2,763
0.065
Floor Construction Type:
X❑ Slab Floor
Building Type:
Single Fam Detached
0.065
❑ Raised Floor
Building Front Orientation:
(Northeast) 45 deg
❑
Number of Dwelling Units:
1.00
❑
Total Conditioned Volume:
27,077
Number of Stories:
1
Slab Floor Area:
2,763
BUILDING ZONE INFORMATION
❑
# of
Thermostat Vent
Zone Name
Floor Area
Volume
Units Zone Type
Type Hgt. Area
Existing Heat/Cool Units
2,763
27,077
1.00 Conditioned
Setback 2 n/a
0
OPAQUE SURFACES Act.
Type Area U -Val. Azm. Tilt
Som
Gains
Y/N
Roof
2,747
0.034
0
0
Wall
325
0.065
45
90
Door
24
0.387
45
90
Door
18
0.387
45
90
Wall
604
0.065
135
90
Wall
302
0.065
225
90
Wall
728
0.065
315
90
Form 3 Reference
Location / Comments
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existina House
Run Initiation Time: 07/21/00 13:17:00 Run Code: 964210620
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:8 of 24
❑
R-30 Roof (R.30.2x12.16)
❑
R-19 Wall (W.19.2x6.16)
❑
Solid Wood Door
❑
❑
Solid Wood Door
R-19 Wall (W.19.2x6.16)
❑
R-19 Wall (W.19.2x6.16)
❑
R-19 Wall (W.19.2x6.16)
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Location / Comments
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existina House
Run Initiation Time: 07/21/00 13:17:00 Run Code: 964210620
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:8 of 24
- Computer Method Summary (Part 2 of 3) C -2R
Haber ect Title ate
ber Residence (Existing) 7/21/00
U -Value Act. Glazing Type Location/
# Type Area SHGC Azm. Tilt Comments
1 Skylight
Right
(North)
16.0 0.940
0.60
0
0 Double Mtl Tinted Default
Existing House
2 Window
Front
(Northeast)
80.0 0.850
0.70
45
90 Double Mtl Uncoated Default
Existing House
3 Window
Front
(Northeast)
18.0 0.720
0.73
45
90 Double Mtl Uncoated Default
Existing House
4 Window
Front
(Northeast)
14.1 0.720
0.73
45
90 Double Mtl Uncoated Default
Existing House
5 Window
Front
(Northeast)
9.8 0.720
0.73
45
90 Double Mtl Uncoated Default
Existing House
6 Window
Front
(Northeast)
9.8 0.720
0.73
45
90 Double Mtl Uncoated Default
Existing House
7 Window
Left
(Southeast)
32.0 0.870
0.70
135
90 Double Mtl Uncoated Default
Existing House
8 Window
Left
(Southeast)
8.0 0.870
0.70
135
90 Double Mtl Uncoated Default
Existing House
9 Window
Left
(Southeast)
8.0 0.870
0.70
135
90 Double Mtl Uncoated Default
Existing House
10 Window
Left
(Southeast)
32.0 0.870
0.70
135
90 Double Mtl Uncoated Default
Existing House
11 Window
Left
(Southeast)
80.0 0.850
0.70
135
90 Double Mtl Uncoated Default
Existing House
12 Window
Left
(Southeast)
25.0 0.720
0.73
135
90 Double Mtl Uncoated Default
Existing House
13 Window
Left
(Southeast)
48.0 0.720
0.73
135
90 Double Mtl Uncoated Default
Existing House
14 Window
Left
(Southeast)
48.0 0.850
0.70
135
90 Double Mtl Uncoated Default
Existing House
15 Window
Rear
(Southwest)
80.0 0.850
0.70
225
90 Double Mtl Uncoated Default
Existing House
16 Window
Rear
(Southwest)
25.0 0.720
0.73
225
90 Double Mtl Uncoated Default
Existing House
17 Window
Rear
(Southwest)
24.0 0.720
0.73
225
90 Double Mtl Uncoated Default
Existing House
18 Window
Rear
(Southwest)
10.0 0.720
0.73
225
90 Double Mtl Uncoated Default
Existing House
19 Window
Rear
(Southwest)
48.0 0.850
0.70
225
90 Double Mtl Uncoated Default
Existing House
20 Window
Rear
(Southwest)
48.0 0.720
0.73
225
90 Double Mtl Uncoated Default
Existing House
21 Window
Right(Northwest)
2.0 0.720
0.88
315
90 Glass Block
Existing House
22 Window
Right
(Northwest)
25.0 0.720
0.73
315
90 Double Mtl Uncoated Default
Existing House
23 Window
Right
(Northwest)
7.5 0.870
0.70
315
90 Double Mtl Uncoated Default
Existing House
INTERIOR AND EXTERIOR SHADING
Window Overhang
Left Fin Right Fin
# Interior Shade
Type SHGC Exterior Shade Type
SHGC
Hgt. Wd. Len. Hgt. LExt.RExt.Dist. Len. Hgt. Dist. Len. Hgt.
one
one
1:0
2 Drapery
0.68 Bug Screen
0.76
8.0 10.0 2.0 0.1 2.0 2.0
3 Drapery
0.68 Bug Screen
0.76
4 Drapery
0.68 Bug Screen
0.76
2.4 6.0 -4.0-0.1 4.0 4.0
5 Drapery
0.68 Bug Screen
0.76
Drapery
0.68 Bug Screen
0.76
_
7- Drapery
0.68 Bug Screen
0.76
_
-8- Drapery
x:66 Bug Screen
-
9 tYrapery
0.68 Bug Screen
0.76-
10 Drapery
0.68 Bug Screen
0.76
1'f Drapery
ug Screen
X75
- - - - -
fl Drapery
036 BugScreen
075
2.510.0 10.0 0.1 10.0 10.0
13 Drapery
-:GS Bug Screen
_YM
- - - - -
1-4 Drapery
-:68 Bug Screen
-T-79
8.0 6.0 8.0 0.1 8.0 8.0
T5 Drapery
-0-.98 BugScreen
0:75
- - - - -
1-6 Drapery
--6B BugScreen
076-
2.5 10.0 -f0.0 -0. 1 10.0 10.0
17 Drapery
0.68 Bug Screen
0.76
T8f Drapery
X36 BugScreen
-OTS
- - - - -
19 Drapery
-:M8 Bug Screen
QTS
-" 01 9-0 8.0
30 Drapery
-TOung
creen
X7-5
- - - - -
31f Drapery
-:GB Bug Screen
QTS
--
22 Drapery
0.68 Bug Screen
0.76
23 Drapery
0.68 Bug Screen
0.76
Run Initiation Time: 07/21/00 13:17:00 Run Code: 964210620
EnergyPro 2.1
By Ener Soft User Number: 3665
Job Number: 901.13A
Page:9 of 24
Computer Method Summary (Part 3 of 3) C -2R
Haber Residence (Existing) 7/21/00
Aft,-P—roi-e-cf I itie uate
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Concrete, Heavyweight 2,072 3.50 28 0_98 n/a 0 Existing House / Slab on Grade
Concrete, Heavyweight 691 3.50 28 0.98 n/a 2 Existing House / Slab on Grade
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab erimeter 192 0.76 0.0 0 Existing House
Slab Perimeter 103 0.76 0.0 0 Existing House
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic,
etc.)
R -Value Type
Comments
Central Furnace
78%AFUE
Ducts in Attic
4.2 Setback
Existing Heat/Cool Units
. Hydronic Piping Pipe
Pipe
Insul.
System Name Length
Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
Split Air Conditioner
10.0 SEER
Ducts in Attic
4.2 Setback
Existing Heat/Cool Units
WATER HEATING SYSTEMS
Ratedl Tank
Energy Facts 1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery Standby R -Value
System Name
Type
Type
Syst. (Btu/hr) (gal)
Efficiency Loss (%) Ext.
Standard Gas 50 gal or Less
Small Gas
Standard
1 40,000 50
0.53 n/a 12
•
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous. gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 07/21/00 13:17:00 Run Code: 964210620
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:10 of 24
0
10
Computer Method Summary (Addendum) C2 -R
Haber Residence (Existi
7/21/00
Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
+oaca. — u— oucy Vaa.r VI al le aP..lai JUaan .. W.. a.. uWUUlnenwu vn . UV1111 LLVU.
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanke .
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2072 sqft Exposed Slab Floor, 3.50" thick at Existing House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 691 sqft Covered Slab Floor, 3.50" thick at Existing House
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
.:.1w TI-_ U=me _a_ ..� J_ .-. aL_ s:_IJ _:
p1mv-1. I Ile n cru IaLV1 IIIUaL UVVUIIIem me IIV1U ve1111L:a LIV11 411U U1C1911U,L11: LVSL1119 V1 LIIV'V 111V45UfV5 U11 d IOU" --r-em. an ie
RunInitiation Time: un Code: 964210620
EnergyPro 2.1 By EnergySoft User Number: 3666 Job Number: 901.13A Page: 11 of 24
INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R
•
-Site Address Permit Number
An installation certificate is required to be posted at the building site or made available for all appropriate inspections.
(The information provided on this form is required; however, use of this form to provide the information is optional.)
After completion of final inspection, a copy must be provided to the building department (upon request) and the
building owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heating Equipment
Equip.
Type (pkg.,
heat pump)
CEC Certified Mfr Name
& Model Number
# of
Identical
Systems
Efficiency' Duct
(AFUE, etc.)) Location
[>= CF -1 R Value] (attic, etc.)
Duct or
Piping
R -Value
Heating
Load
(Btu/hr)
Heatingg
Capacity
(Btu/hr)
Cooling Equipment
Equip.
CEC Certified Compressor
# of
Efficiency' Duct
Cooling
Cooling
Type (pkg.
Unit Mfr Name &
Identical
(SEER, etc.)) Location
Duct or
Load
Capacity
heat pump
Model Number
Systems
[>= CF -1 R Value] (attic, etc.)
R -Value
(Btu/hr)
(Btu/hr)
1. — reads Greater Than or Equal to.
I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent
to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the
Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate
requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
WATER HEATING SYSTEMS:
CEC Certified Distribution If Recir- # of Rated2 Tank Effi-2 2 External
Heater Mfr Name Type(Std, culation, Identical Input (kW Volume ciency Standby Insulation
Type & Model Number Point -of -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (%) R -Value
2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input.
For instantaneous gas water heaters, list Recovery Efficiency and Rated Input.
3 R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58.
Faucets & Shower Heads:
All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111
I, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to
or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy
Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for
manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
COPY TO: Building Department OR General Contractor (Co. Name) OR Owner
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By EnergySoft User Number: 3666 Job Number: 901.13A Page: 12 of 24
INSTALLATION CERTIFICATE (Part 2 of 7) CF -6R
�Ite Address -P—ermit Number
FENESTRATION / GLAZING:
Product U- Product Interior or.
Value 1 SHGC1 Exteror Shading
(=<CF -1 R (=< CF -1 R # of Quantity Square Device or Comments/
Manufacturer/Brand Name value)2 valuey Panes (Optional) Feet Overhang Special Features
GROUP LIKE PRODUCTS
3
4
9.
10.
11.
12.
13.
14.
15.
1. Manufactured Fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 116 of the Energy Efficiency Standards.
2. Installed U -value must be less than or equal to values from CF -1 R. Installed SHGC must be less than or equal to values from CFAIR, or a shading device (interior, exterior or overhang) is
installed as specified on the CFAR. Alternatively, installed weighted average U -values for the total fenestration area are less than or equal to values from CFAR.
I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2)
is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance (Form CF -1 R)
submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds
the appropriate requirements for manufactured devices (from Part 6), where applicable.
Item #s Igna ure, Date
(if applicable)
Item #s Signature, Date
(if applicable)
Item #s Signature, Date
(if applicable)
-ns a ling Su con rac or(Co.Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 13 of 24
u
C
INSTALLATION CERTIFICATE (Part 3 of 7) CF -6R
Sia Address
DUCT DIAGNOSTICS
Permit Number
This buiding obtained compliance credit for: ❑ Duct sealing ❑ Duct Area Reduction
❑ ACCA Manual D design and installation
CREDIT FOR REDUCED DUCT SURFACE
AREA OR LOCATION
Duct Location* Exterior Measured
Surface Area Exterior Surface
(CFAR) Area
❑ Attic
❑ Crawlspace
❑ Basement
❑ Other
Total
ACCA Design
❑ Duct Design on Plans
❑ Installed duct diameters match plans
❑ TXV installed
❑' Access to TXV valve (if installed)
❑ No TXV, Fan air flow (CFM)_
❑ Duct Leakage Measured
❑ Measured leakage (CFM)
HVAC fan air flow (CFM) (measured or calculated as
'Ignore ducts in
❑
conditioned space. CFM = 0.7 x Anoor for CZ 8 through 15
Only a check is ❑CFM = 0.5 x Anoor for CZ 1 through 7 & 16
required_ for location or, it the equipment size is known, the larger of 1 or 2.
credit. 1. [:]CFM = 400 x Cooling Capacity in Tons or
2. ❑ CFM = 21.7 x Heating Capacity in Thousands of Btu per hour)
Leakage divided by HVAC Fan air flow (must be =< 0.06)
For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed:
❑ Duct Fan Pressurization at rough-- in measured leakage CFM CHECK AFTER FINISHING WALL:
❑ Pressure Pan Test ❑ House pressuezation test ❑ Visual Inspection of Duct Connections
Provide Follow-up Test Results or Inspection Results on a Separate Page
❑ This certifies that the ducts surface area and duct locations were verified.
When compliance credit is claimed for duct surface area reducitons and duct location improvements beyond those covered by default
assumptions, builder employees or subcontractors shall certify that they have verified that the duct surface area and locations match those
on the plans and shall indicate the duct surface area in each duct location on the CF6R.
F-] This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with
the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.]
Tests Signature, Daten-lallingSu con rac or o. Name)
Performed OR General Contractor ( o. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 14 of 24
INSTALLATION CERTIFICATE (Part 4 of 7) CF -6R
0 Site Address -Permit Number
BUILDING ENVELOPE LEAKAGE DIAGNOSTICS
This buiding obtained compliance credit for: El Envelope sealing using diagnostic testing (CF -1 R)
Needed for Compliance Measured Blowerdoor Test
(from CF -1 R) Results
-Building Envelope Leakage (CFM @ 50 Pa)
-Leakage level equivalent to an SLA of 3.0 from CF -1 R
-Minimum Building Leakage equivalent to an SLA of 1.5
from CFAR (CFM @ 50 Pa)
❑ Yes ❑ No Is design infiltration less than the SLA 3.0 equivalant (from CF -1 R)?
❑ Yes ❑ No Is mechanical ventilation installed? (Required if design is less than 3.0 SLA)
RYes ❑ No Is measured leakage (without fans operating) less than minimum in the above Table (1.5 SLA from CF -1 R)?
F-1 Yes R No Is mechanical supply ventilation installed to assure house pressure does not go below minus 5 Pascal relative to
outside ambient with all exhaust fans operating?
Mechanical Ventilation - Fill in Table if mechanical ventilation is installed
Used for Compliance
(from CF -1 R)
-Continuous Mechanical Ventilation (CFM
-Continuous Mechanical Supply Ventilation
(CFM) Required to maintain -5 Pa if building
envelope leakage is less than minimum (see
above)
-Total Power Consumption of Continuous
Mechanical Ventilation (Watts) 2
This certifies that the building leakage was verified.
Measured
Actual
When compliance credit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall
certify that they have verified that the building leakage level matches that used for compliance on the CF -6R and shall document the
infiltration levels required for compliance and the tested infiltration values on the CF -6R..
❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with
the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.]
Tests Signature, a enl stalling Su con rac or Co.Name)
Performed OR General Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
1. When mechanical ventilation is required, CFM less than 0.047 CFM per square foot of conditioned floor area indicates failure to achieve compliance
• 2. As determined from label on fan or manufacturers literature.
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: IS of 24
INSTALLATION CERTIFICATE (Part 5 of 7) CF -6R
0Sete AddressPermit-Number
0
The following is an explanation of many of the input values required on this form:
HVAC SYSTEMS
Heating Equipment Type must be one of the following:
Furnace:
Gas (including Liquefied Petroleum Gases) or oil -fired central furnace & space heater
Boiler:
Gas or oil -fired boiler
PckgHeatPump:
Packaged central heat pump
SplitHeatPump:
Split central heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (>=65,000 Btu/hr output)
Electric:
Electric resistance heating (fixed HSPF = 3.413); radiant electric resistance
(fixed HSPF = 3.55)
CombinedHydro:
I Reference water heater under water heating systems below
-CEC Certified Manufacturer Make & Model Number from applicable Commission approved appliance directory.
-"# of Identical Systems" is for those systems with the same efficiency, duct location, duct R -Value and capacity.
-Efficiency from applicable Commission certified appliance directory.
-Duct Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none.
-Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data.
-Heating/Cooling Load refer to Commission approved load calculation procedure.
-Heating/Cooling Equipment Capacity from the applicable Commission certified appliance directory. Note: location
elevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's literature).
Cooling Equipment Type must be one of the following:
SplitAirCond:
Split system air conditioner
PckgAirCond:
Packaged air conditioner
SplitHeatPump:
Split system heat pump
PckgHeatPump:
Packaged heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (-65,000 Btu/hr output). Substitute EER for
SEER when SEER is not available.
RoomAirCond:
Room air conditioner. Minimum SEER varies*
LrgPkgAirCond:
Large packaged air conditioner (>=65,000 Btu/hr output). Substitute EER for
SEER when SEER is not available.
EvapDirect:
Direct evaporative cooling system. For compliance calculation
purposes, fixed values:
SEER = 11.0; duct location = attic;
duct insulation R -value = 4.2
Evapindirect:
Indirect evaporative cooling system. For compliance calculation
purposes, fixed values:
SEER = 13.0; duct location = attic;
duct insulation R -value = 4.2
*Refer to California Energy Commission (CEC) publication Appliance Efficiency Regulations, P400-92-029
EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: 901.13A Page: 16 of 24
•
INSTALLATION CERTIFICATE (Part 6 of 7) CF -611
SI a Address Permit Number—
The following is an explanation of many of the input values required on this form:
WATER HEATING SYSTEMS
Distribution Systems: Refer to Residential Manual for more details.
Standard:
Standard - Supply prssure based system, no pumps
Pipe Insulation:
Pipe Insulation on all 3/4 -inch pipes
POU/HWR:
Point of Use/Hot Water Recovery System
Recirc/NoControl:
Recirculation loop with no controls
Recirc/Timer:
Recirculation loop with a timer
Recirc/Temp:
Recirculation loop with temperature control
Recirc/Time + Temp:
Recirculation loop with a timer and temperature control
Recirc/Demand:
Recirculation loop with demand control
Water Heater Type
Storage Gas, Oil or Electric
Heat Pump
Instantaneous Gas
Instantaneous Electric
Large Storage Gas
Indirect Gas (Boiler)
Information Needed
Energy Factor
Recovery Efficiency
Standby Loss
Rated Input
Yes
No
No
No
Yes
No
No
No
No
Yes
No
No
Yes
No
No
No
No
Yes
Yes
Yes
No
Yes (AFUE)
No
Yes
FENESTRATION / GLAZING
Fenestration:
Windows, sliding glass doors, french doors, skylights, garden windows, and
any door with more than one square foot of glass
Operator Type;
Slider, hinged, fixed
U -Value:
Installed U -Value must be less than or equal to value from CF -1 R
OR
Installed weighted average U -Value for the total fenestration area
is less than or equal to value from CF -1 R
SHGC:
Installed SHGC must be less than or equal to value from CF -1 R
OR
Installed SHGC for the total fenestration area is less than or equal to value
from CF -1 R
OR
An interior shading device, overhang, or exterior shading device is installed
consistent with the CF -1 R
ShadingDevice:
Include when the building complied using an interior shading device: blinds,
opaque roller shades, blinds (do not list draperies), an exterior shading
device: woven sunscreen, louvered sunscreen, low sun angle sunscreen,
roll -down awning, roll -down blinds or slats (do not list bug screen), or an
overhang (include depth in feet)
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 17 of 24
0
INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R
Site Address P—er-mit Number
The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3
of 6):
TYPE OF CREDIT
Refer to Residential Manual Chapters 4 and 5 for more details:
Reduced Duct Surface
Calculated as the outside area of the duct. Areas must be measured and
Area:
verified by HERS rater.
Improved Duct Location:
Supply duct located in other than attic, as verified by location of registers
(does not require HERS rater verification).
Catastrophic Leakage:
Pressure pan test reading must be less than 1.5 Pascal at a house pressure
of 25 Pascal.
TXV:
Access cover required to facilitate verification.
Infiltration Reduction:
Infiltration is measured without mechanical ventilation operating.
Mechanical ventilation is required for very tight house construction when
credits for infiltration reduction using diagnostic testing are beng used for
achieving compliance. These very tight houses are defined as those with
SLA of less than 1.5. The compliance documentation (CF -1 R) will contain
the measured CFM target value from a blower door test at 50 Pascal
pressure difference that represents this SLA of 1.5. Mechanical ventilation
is also required if the builder chooses to design the building to use
mechanical ventilation and claims a credit for infiltration below an SLA of
3.0. The compliance documentation (CF -1 R) will contain the measured
CFM target value that represents this 3.0 SLA. If the builder claims credit
in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and
the actual measured SLA is 1.5 or greater, then mechanical ventilation is
not required. If the SLA in this case were below 1.5, then mitigation (such
as mechanical ventilation) would be required.
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 18 of 24
0
iVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Haber Residence (Existing) 7/21/00
SYSTEM NAME FLOOR AREA
Existing Heat/Cool Units 2,763
Number of Systems
2
Heating System
Output per System
80,000
Total Output (Btuh)
160,000
Output (Btuh/sqft)
57.9
Cooling System
Output per System
46,000
Total Output (Btuh)
92,000
Total Output (Tons)
7.7
Total Output (Btuh/sgft)
33.3
Total Output (sgft/Ton)
360.4
Air System
CFM per System
1,740
Airflow (cfm)
3,480
Airflow (cfm/sgft)
1.26
Airflow (cfm/Ton)
453.9
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 of 69.1 of
Outside Air
0 cfm
Supply Fan
3480 cfm
69.1 OF
11.0 177.4 of
Ou -Ai
-
0 cfm
79.0168.8 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
5,689
74,982
6,908
1,584
69,667
0
3,749
3,483
0
0
0
0
0
0
0
0
0
3,749
3,483
182,480 6,908 76,633
Existing Heat/Cool Units 53,368 34,107 160,000
Total Adjusted System Output 53,368 34,107 160,000
(Adjusted for Peak Design Conditions)
69.1 of® 112.0 of
Heating Coil
79.0/68.8OF 79.0/68.8OF
TIME OF SYSTEM PEAK F Aug 2 pm I Jan 12 am
ng
�, Return Air Ducts 4
64.7 / 63.8 of
Supply Fan Cooling Coil
3480 cfm
S, Return Air Ducts 4
Supply Air Ducts
111.0 of
ROOMS
70.0 of
Supply Air Ducts
65.7/64.1OF
62.2% R.H. ROOMS
78.0 / 68.5 of
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 19 of 24
E U
E
ROOM LOAD SUMMARY
PROJECT NAME
DATE
Haber Residence (Existing)
7/21/00
SYSTEM M
FLOOR AREA
Existing Heat/Cool Units
2,763
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:20 of 24
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Existing House
xisting Ouse
1
5,689
74,982
6,908
5,689
74,982
6,908
1,584
69,667
PAGE TOTAL 5,689 74,982 6,908 1,584 69,667
TOTAL 1 5,689 74,982 6,908 1,584 69,667
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:20 of 24
ROOM HEATING PEAK LOADS
Project Title Date
Haber Residence (Existing) 7/21/00
Room Information Design Conditions
Room Name E)dsting House Time of Peak Jan 12 am
Floor Area 2,763 Outdoor Dry Bulb Temperature 26°F
Indoor Dry Bulb Temperature 70 OF
Conduction
Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 48,379
Infiltration: I 1.00 x 1.072 x 2,763 x 9.80 x 1.00 /6 x
L c .0 e Air Sensible:
Area Coiling Height ACHJ AT
Fraction
91 TOTAL HOURLY HEAT LOSS FOR ROOM 69,667
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 21 of 24
Area
X
X
X
X
X
X
x
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
U -Value
X
X
X
X
X
X
x
x
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
AT of
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
2,747.0
0.0341
44.0
4,116
16.0
0.9400
44.0
662
1,959.6
0.0655
44.0
5,643
42.3
0.3872
44.0
721
336.0
0.8500
44.0
12,566
256.6
0.7200
44.0
8,130
87.5
0.8700
44.0
3,350
2.0
0.7200
44.0
63
perimeter 295.0
44.5
13,128
Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 48,379
Infiltration: I 1.00 x 1.072 x 2,763 x 9.80 x 1.00 /6 x
L c .0 e Air Sensible:
Area Coiling Height ACHJ AT
Fraction
91 TOTAL HOURLY HEAT LOSS FOR ROOM 69,667
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 21 of 24
E
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing) 7/21/00
Project Title Date
Room Name Existing House
Design Indoor Dry Bulb Temperature: 78°F
Design Outdoor Dry Bulb Temperature: 112°F
Design Temperature Difference: 340F
Conduction
R-30 Roof (R.30.2x12.16)
Double Mtl Tinted Default
R-19 Wall (W.19.2x6.16)
Solid Wood Door
Double Mtl Uncoated Default
Double Mtl Uncoated Default
Double Mtl Uncoated Default
Blass Block
Area U -Value
2,747.
16.
1.959.
87
0
0
0
x
x
x
x
X
X
X
X
DETD 1
=
=
=
=
=
=
=
=
Btu/hr
51.0
4,771
34.0
511
30.6
3,925
30.6
501
34.0
9,710
34.0
6,282
34.0
2,588
34.0
49
X
1. Design Equivalent Temperature Difference (DETD) Page Total 28,338
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Skylight
(Skylight)
1
(Northeast)
2
(Northeast)
3
(Northeast)
4
(Northeast)
5
(Northeast)
6
(Southeast)
7
(Southeast)
8
(Southeast)
9
(Southeast)
( 0.0
X
x1
X
X
x
X
X
X
x
X
1
+
+
+
+
+
+
+
+
+
+
16.0
X
X
X
x
x
x
x
X
X
X
152)
X
x
X
X
x
x
x
X
X
X
0.690
=
=
=
=
=
=
=
=
=
=
1,677
( 0.0
80.0
48)
0.720
2,765
( 0.0
1
18.0
48)
0.727
628
(-0.0
1
14.1
48)
0.727
493
( 0.0
1
9.8
48)
0.727
340
(-0.0
1
9.8
48)
0.727
340
( 0.0
1
32.0
62)
0.720
1,429
( 0.0
1
8.0
62)
0.720
357
(0.0
1
8.0
6)
0.720
357
( 0.0
1
32.0
62)
0.720
1,429
Sched. Page Total x,815
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 2,763 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0
Occupants 1.00 x 2,763 X 245 Btuh/OCC. / 250 sgftlocc. = 2,708
Receptacle 1.00 X 2,763 x 0.200 Watts/sgft x 3.413 Btuh/Watt = 1,886
Process 1.00 X 2,763 X 0.000 Watts/sgft x 3.412 Btuh/Watt = 0
Infiltration: 1.00 X 1.072 X 2,763 X 9.80 X 1.00 / 60] 34 = 16,450
c e u e r ens a rea a ng e g C Q
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 74,982
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 2,763 X 155 Btuh/OCC. / 250 sgftlocc.= 1,713
Receptacle 1.00 X 2,763 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o
Process 1.00 x 2,763 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: 1 1.001 x 4,806 x 2,763 x 9.80 X 1.00 / 60] 0.00240 = 5,195
ceue en Area ceilingHeightICC pW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,908
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 22 of 24
E
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing) 7/21/00
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Existing House
78OF
112°F
Conduction Area U -Value DETD 1
x
1. Design Equivalent Temperature Difference (DETD) Page Total
Items shown with an asterisk (*) denote conduction throughn interior surface to another room.
SWa'ded Unshaded
Solar Gain Orientation Area SGF Area SGF SC
10
(Southeast)
11
(Southeast)
12
(Southeast)
13
(Southeast)
14
(Southwest)
15
(Southwest)
16
(Southwest)
17
(Southwest)
18
(Southwest)
19
(Southwest)
340E
Btu/hr
0
Btu/hr
0.0
x
X
x
x1
X
X
x
X+
xAll
X+
1 +
1 +
I,- +
+
1 +
1 +
1 +
+
80.0
X
x
X
x
X
X
X
X
X
X
62)
X
X
X
X
X
x
X
X
X
0.720
=
=
=
=
=
=
=
=
-
=
3,572
25.0
0.0
62)x
0.727
272
0.0
48.0
62)
0.727
2,162
48.0
0.0
62)
0.720
518
0.0
80.0
62)
0.720
3,572
25.0
0.0
62)
0.727
272
0.0
24.0
62)
0.727
1,081
0.0
10.0
62)
0.727
451
48.0
0.0
6)
0.720
518
0.0
48.0
62)
0.727
2,162
Sched. Page Total 1x,582
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 2,763 x 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Occupants 1.00 X 2,763 x 245 Btuh/occ. / 250 sgft/OCC. = 2,708
Receptacle 1.00 X 2,763 x 0.200 Watts/sgft X 3.413 Btuh/Watt = 1,886
Process 1.00 x 2,763 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: [ 1.00 x 1.072 x 2,763 x 9.80 x 1.00 / 60] 34 = 16,450
s-. u e r ens a Area e 1 ng e g Ac p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 74,982
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 2,763 X 155 Btuh/occ. / 250 sgft/OCC. = 1,713
Receptacle 1.00 X 2,763 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0
Process 1.00 x 2,763 x 0.000 Watts/sgft x 3.41J,Btuh/Watt = 0
Infiltration: [ 1.00 x 4,806 x 2,763 x 9.80 x 1.00 / 60] 0.00240 = 5,195
c e u e r a en Area a ng e g AC /-\yy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,908
EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: 901.13A Page: 23 of 24
0
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing) 7/21/00
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb. Temperature:
Design Temperature Difference:
Conduction
Area U -Value
Existing House
780F
112OF
340F
1. Design Equivalent Temperature Difference (DETD) o Page Total
Items shown with an asterisk (*) denote conduction thrQuahh adn interior surfacenadednother room.
Solar Gain Orientation AreaSGFSGF Area SGF SC
20
21
22
Btu/hr
0
Btu/hr
(Northwest)
( 0.0
( 0.0
( 0.0
(
(
(
(
(
(
(
x
X
x
x
X
x
x
x
x
x
1
+
+
+
+
+
+
+
+
+
+
2.0
X
x
x
x
X
X
X
x
x
X
48)
X
x
x
)x
)X
)x
)X
)x
)x
)X
0.757
=
=
=
=
=
=
=
73
(Northwest)
1
25.0
48)
0.727
872
(Northwest)
1
7.5
48)
0.720
259
Sched. Page Total 1,204
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 2,763 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0
Occupants 1.00 X 2,763 X 245 Btuh/OCC. / 250 sgft/occ. = 2,708
Receptacle 1.00 X 2,763 x 0.200 Watts/sqft x 3.413 Btuh/Watt = 1,886
Process 1.00 x 2,763 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0
Infiltration: 1.00 X 1.072 X 2,763 x9.80 xET6�] 34 = 16,450
ceue A(r Senslb a rea e -TI ng e g AC p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 74,982
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 2,763 x 155 Btuh/OCC. / 250 sgft/OCC. = 1,713
Receptacle 1.00 X 2,763 X 0.000 Watts/sqft X 3.41 Btuh/Watt = 0
Process 1.00 x 2,763 X 0.000 Watts/sqft x 3.41J,BtuhfWatt = 0
Infiltration: L
1.00 x 4806 x 2763 x 980 x 1.00 / 60]eue r Latent Area ell ng Height c pyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,908
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 24 of 24
TITLE 24 REPORT
Title 24 Report for:
Haber Residence (Existing + Addition)
56-485 Riviera
La Qu i nta, CA 92253
Project Designer:.
Robert A. Pitchford
41-625 Eclectic Ste. A-2
Palm Desert, CA 92260
(760) 346-2856 .
Report Prepared By:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
(760) 346-0855
Job Number:
901.13A
Date:
7121/00
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 2.1 By EnergySoft Job Number: 901.13A User Number: 3665 1
0
•
•
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Haber Residence (Existing + Addition) 7/21/00
roiec i e Date
56-485 Riviera La Quinta
vrolect Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
uocumentation Autnor i a ep one
Computer Performance 15
Building ermi
Plan Check / Date
ield L;heck I Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION .
Total Conditioned Floor Area: 3,176 ft2
Total Conditioned Slab Area: 3,176 f?
Building Type:
(check one or more)
® Single Family Detached (SFD) ❑ Addition Alone
❑ Single Family Attached (SFA) ❑ Existing Building
❑ Multi -Family ® Existing Plus Addition
Front Orientation: (Northeast) 45 deg
Number of Dwelling Units: 1.00
Number of Stories: 1
BUILDING SHELL INSULATION
Component
Type
Frame
Type
R-30 Roof (R.30.2x12.16)
Wood
R-19 Wall (W.19.2x6.16)
Wood
Solid Wood Door
None
Slab On Grade
n1a
Slab On Grade
Na
R-38 Roof (R.38.2x14.16)
Wood
R-21 Wall (W.21.2x6.16)
Wood
Skylight
16.0
0.94
0.60
FENESTRATION
Floor Construction Type: 0 Slab Floor
❑ Raised Floor
Const.
Assembly Location/Comments
U -Value (attic, garage, typical, etc.)
0.034 Exterior Roof
0.065 Exterior Wall
0.387
U.lbb
0.756
Exterior Door
Exposed Slab w/R-0.0 Perimeter Insulation
Covered Slab w/R-0.0 Perimeter Insulation
0.028 Exterior Roof
0.059 Exterior Wall
Shadina Devices
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
(SF)
U -Value
SHGC
(roller blind, etc.)
(shadescreen, etc.)
Yes / No
Yes
/ No
Skylight
16.0
0.94
0.60
None
None
❑
0
❑
Q
Front
(Northeast)
80.0
0.85
0.70
Drapery
Bug Screen
Q
❑
❑
Q
Front
(Northeast)
37.5
0.72
0.73
Drapery
Bug Screen
❑
N
❑
Q
Front
(Northeast)
14.1
- 0.72
0.73
Drapery
Bug Screen
Q
❑
❑
0
Left
(Southeast)
186.7
0.85
0.70
Drapery
Bug Screen
❑
0
❑
Q
Left
(Southeast)
25.0
0.72
0.73
Drapery
Bug Screen
0
❑
❑
0
Left
(Southeast)
72.9
0.72
0.73
Drapery
Bug Screen
❑
Q
❑
0
Left
(Southeast)
48.0
0.85
0.70
Drapery
Bug Screen
0
❑
❑
0
Rear
(Southwest)
80.0
0.85
0.70
Drapery
Bug Screen
❑
®
❑
Rear
(Southwest)
25.0
0.72
0.73
Drapery
Bug Screen
Q
❑
❑
Q
Rear
(Southwest) 130.0
0.72
0.73
Drapery
Bug Screen
❑
0
❑
0
Rear
(Southwest)
48.0
0.85
0.70
Drapery
Bug Screen
®
❑
❑
0
Run Initiation Time: 07/21/00 13:32:02
Run Code: 964211522
EnergyPro 2.1 By Energysoft
User Number: 3665
Job Number: 901.13A
Page:3 of 32
0
Cl
r
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Haber Residence (Existing + Addition) 7/21/00
rojec i e Date
56-485 Riviera La Quinta
rojec IF Ad Tr -e -ss Building Permit
BREEZE AIR CONDITIONING (760) 346-0855
Plan Check I Date
uocumentation Author Telephone
Computer Performance 15 Reld L;heCKa e
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,176 ft2
Total Conditioned Slab Area: 3,176 ft2
Building Type:
(check one or more)
® Single Family Detached (SFD) ❑ Addition Alone
❑ Single Family Attached (SFA) ❑ Existing Building
❑ Multi -Family ® Existing Plus Addition
Front Orientation: (Nodheast) 45 deg Floor Construction Type: [_X] Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
Component Frame Assembly Location/Comments
Type Type U -Value (attic, garage, typical, etc.)
FENESTRATION
Shading Devices
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
(SF)
U -Value SHGC
(roller blind, etc.)
(shadescreen, etc.)
Yes / No
Yes / No
Right
(Northwest)
2.0
0.72 0.88
Drapery
Bug Screen
❑
0
❑ 0
Right
(Northwest)
25.0
0.72 0.73
Drapery
Bug Screen
❑
Q
❑ Q
Right
(Northwest)
7.5
0.87 0.70
Drapery
Bug Screen
❑
0
❑ Q
Front
(Northeast)
8.0
0.72 0.73
Drapery
Bug Screen
❑
Q
0 ❑
F
❑
El Fl
1:1
El
El F-1
El
El
El F-1
F-1
1:1
El F-1
1:1
El
El
El
El
El
El
1:1
1:1 1:1
El
El
El El
Run Initiation Time: 07/21/00 13:32:02
Run Code: 964211522
EnergyPro 2.1 By EnergySoft
User Number: 3665
Job Number: 901.13A
PageA of 32
Certificate of Compliance: Residential
(Part 2 of 2) CF -1 R
Haber Residence
(Existing + Addition)
Setback Existing Heat/Cool Units
7/21/00
• ro/ec i e
Ducts in Attic
4.2
Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment
Minimum Type and
Duct or
Type (furnace, heat
Efficiency Location
Piping
Thermostat Location /
pump, etc.)
(AFUE/HSPF) (ducts, attic, etc.)
R -Value
Type Comments
Central Furnace
78% AFUE Ducts in Attic
4.2
Setback Existing Heat/Cool Units
Split Heat Pump
6.8 HSPF Ducts in Attic
4.2
Setback Office Unit
Cooling Equipment
Minimum Duct
Type (air conditioner,
Efficiency Location
Duct
Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.)
R -Value
Type Comments
0
•
Split Air Conditioner
10.0 SEER
Ducts in Attic
4.2
Setback Existing Heat/Cool Units
Split Heat Pump
10.2 SEER
Ducts in Attic
4.2
Setback Office Unit
Tank Energy Facts 1 External
WATER HEATING SYSTEMS
Rated 1
Water Heater
Water Heater
Distribution
# in Input
Cap. or Recovery Standby Tank Insul.
System Name
Type
Type
Syst. Btu/hr
(gal) Efficiency Loss (%) R -Value
American G52-50T383NV Small Gas Recirc/Time+Temp 1 38,000 50 0.62 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm
Address:
Robert A. Pitchford
41-625 Eclectic Ste. A-2
Name:
Title/Firm:
Address:
Telephone:
Name:
Title/Firm:
Address:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT. CA 92211
Telephone: (760) 346-0 55
OD . Im
>) (signature) " I (date)
signature stamp date
Run Initiation Time: 07/21/00 13:32:02 Run Code: 964211522
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A ' Page:5 of 32
Certificate of Compliance: Residential (Addendum) CF -1 R
Haber Residence (Existing + Addition) 7/21/00
• Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
•
•
4aDCY YII LI R -i aY W%4000r YI L 1 2 PwC a JUJIIIR.al1Y11 011Y UUI.U111U11La11U11 SUUMILLUU. Plan I Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2072 sqft Exposed Slab Floor, 3.50" thick at Existing House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 691 sqft Covered Slab Floor, 3.50" thick at Existing House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 54 sqft Exposed Slab Floor, 3.50" thick at Addition to Bedroom's
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 140 sqft Covered Slab Floor, 3.50" thick at Addition to Bedroom's
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 219 sqft Exposed Slab Floor, 3.50" thick at Office
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
...w..:Jw� 'M U 0 �..�..� ..-....� Jww..rww� �Lw L:wIJ ..w -.r ��a.�� ��J J:��.-��a:� a���:.-_ _L
- ..�..� .�.�. ...��. ���..... �... ...� ......- .... ........................�. vv..v .vv.. .� ...vvv ... v..v r.vv v.• r •v...• v• -v...
Run Initiation ime: un Cod-e-96421152
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:6 of 32
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk(*) maybe superseded by more stringent compliance requirements listed on the Certificate of
• Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties
as binding minimum component specifications.
0
0
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMEN
Building Envelope Measures
®'§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -value.
N150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls).
F"§ 150(d): Minimum R-13 raised floor insulation in wood framed floors.
§ 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch.
® §118: Insulation specified or installed meets quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
® §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
191 §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
® §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.
® §150(i): Setback thermostat on all applicable heating and/or cooling systems.
® §1506): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined internal/external insulation, piping between heat source and tank insulated.
3.Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R-4 or greater), buried or exposed
piping in recirculating sections of hot water systems, cooling system piping below 55 deg F.
®'§150(m): Ducts and Fans
1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections
601 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shall be
sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181,
UL181 S, or UL181B and other applicable specified test for longevity given in 150(m).
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated
dampers.
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating.
2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light.
Lighting Measures
® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
® 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed
ceiling are IC (insulation cover) approved.
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:7 of 32 1
- Computer Method Summary (Part 1 of 3) C -2R
Haber Residence (Existing + Addition) 7/21/00
•�rojecfTitle Date
56-485 Riviera La Quinta
vroject Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
bocumentation Author I a ep one
Computer Performance 15
-comp lancee o acac a�Zompu er Climate Zone,
Building ermi
Plan CheclUDate
Reld ChecluDate
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
4.46
3.12
1.33
219
Space Cooling
39.40
66.96
-27.57
Domestic Hot Water
8.97
7.44
1.54
Totals
52.82
77.52
-24.70
Solar
GENERAL INFORMATION
Conditioned Floor Area:
3,176
SURFACES
Floor Construction Type:X❑
Slab Floor
Building Type:
Single Fam Detached
❑ Raised Floor
Building Front Orientation:
(Northeast) 45 deg
Area
U -Val.
Number of Dwelling Units:
1.00
Y / N
Total Conditioned Volume:
30,675
Number of Stories:
1
2,747
Slab Floor Area:
3,176
BUILDING ZONE INFORMATION
❑
# of
Thermostat Vent
Zone Name
Floor Area
Volume
Units Zone Type
Type Hgt. Area
Existing
Heat/Cool Units
2.957
28.594 0.93
Conditioned Setback 2 n/a
Office Unit
219
2,080 0.07
Conditioned Setback 2 n/a
Solar
OPAQUE
SURFACES
Act.
Gains
Type
Area
U -Val.
Azm.
Tilt
Y / N
Form 3 Reference
Location / Comments
Roof
2,747
0.034
0
0
❑
R-30 Roof (R.30.2x12.16)
Existing House
Wall
325
0.065
45
90
❑
R-19 Wall (W.19.2x6.16)
Existing House
Door
24
0.387
45
90
❑
Solid Wood Door
Existing House
Door
18
0.387
45
90
Solid Wood Door
Existing House
Wall
170
0.065
135
90
❑
R-19 Wall (W.19.2x6.16)
Existing House
Wall
225
0.065
225
90
❑
R-19 Wall (W.19.2x6.16)
Existing House
Wall
728
0.065
315
90
❑
R-19 Wall (W.19.2x6.16)
Existing House
Roof
194
0.028
0
0
❑
R-38 Roof (R.38.2x14.16)
Addition to Bedroom's
Wall
31
0.059
45
90
❑
R-21 Wall (W.21.2x6.16)
Addition to Bedroom's
Wall
142
0.059
135
90
❑
R-21 Wall (W.21.2x6.16)
Addition to Bedroom's
Wall
22
0.059
315
90
❑
R-21 Wall (W.21.2x6.16)
Addition to Bedroom's
Roof
219
0.028
0
0
❑
R-38 Roof (R.38.2x14.16)
Office
Wall
84
0.059
135
90
❑
R-21 Wall (W.21.2x6.16)
Office
Door
20
0.387
135
90
❑
Solid Wood Door
Office
Wall
83
0.059
225
90
❑
R-21 Wall (W.21.2x6.16)
Office
Wall
19
0.059
315
90
❑
R-21 Wall (W.21.2x6.16)
Office
❑ ❑
❑ ❑
❑ ❑
❑ ❑
F -1H
00
Run Initiation Time: 07/21/00 13:32:02 Run Code: 964211522
EnergyPro 2.1
By EnergySoR
User Number: 3665 Job Number: 901.13A Pagel of 32
- Computer Method Summary (Part 2 of 3) C -2R
Habect er tle Date
berResidence (Existing + Addition) 7/21/00
U -Value Act. Glazing Type Location/
# Type Area SHGC Azm. Tilt Comments
1
2
i-
4
5
6
7
8
9
10
11
12
13
14
T5-
16
17
18
19
-To-
Y1
021
22
23
24
25
26
Window
Right
(Northwest)
Window
Front
(Northeast)
Window
Leftout
east)
Window
Left
(Southeast)
Window
Left
(Southeast)
Window
Left
(Southeast)
Window
Left
(Southeast)
Window
Rear
(Southwest)
16.0
80.0
18.0
14.1
9.8
9.8
80.0
25.0
48.0
48.0
80.0
25.0
24.0
10.0
48.0
48.0
2.0
25.0
7.5
8.0
53.4
5.3
5.3
53.4
14.2
48.0
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len. Hgt. Dist. Len. Hgt
0.940
0.60
0
0 Double Mtl Tinted Default
0.850
0.70
45
90 Double Mtl Uncoated Default
0.720
0.73
45
90 Double Mtl Uncoated Default
0.720
0.73
45
90 Double Mtl Uncoated Default
0.720
0.73
45
90 Double Mtl Uncoated Default
0.720
0.73
45
90 Double Mtl Uncoated Default
0.850
0.70
135
90 Double Mtl Uncoated Default
0.720
0.73
135
90 Double Mtl Uncoated Default
0.720
0.73
135
90 Double Mtl Uncoated Default
0.850
0.70
135
90 Double Mtl Uncoated Default
0.850
0.70
225
90 Double Mtl Uncoated Default
0.720
0.73
225
90 Double Mtl Uncoated Default
0.720
0.73
225
90 Double Mtl Uncoated Default
0.720
0.73
225
90 Double Mtl Uncoated Default
0.850
0.70
225
90 Double Mtl Uncoated Default
0.720
0.73
225
90 Double Mtl Uncoated Default
0.720
0.88
315
90 Glass Block
0.720
0.73
315
90 Double Mtl Uncoated Default
0.870
0.70
315
90 Double Mtl Uncoated Default
0.720
0.73
45
90 Double Mtl Uncoated Default
0.850
0.70
X35
90 Double Mt1 ncoated De au t
0.720
0.73
135
90 Double Mtl Uncoated Default
0.720
0.73
135
90 Double Mtl Uncoated Default
0.850
0.70
135
90 Double Mtl Uncoated Default
0.720
0.73
135
90 Double Mtl Uncoated Default
0.720
0.73
225
90 Double Mtl Uncoated Default
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Existing House
Addition to Bedroom's
Addition to Bedroom's
Addition to Bedroom's
Addition to Bedroom's
Addition to Bedroom's
Office
Office
one
1.00 None
i 0a
2 Drapery
0.68 Bug Screen
0.76
8.0
10.0
2.0
0.1
2.0
2.0
3 Drapery
0.68 Bug Screen
0.76
,V Drapery
0.68 Bug Screen
0.76
2.4
6.0
-4.0-0.1
4.0
4.0
5 Drapery
0.68 Bug Screen
0.76
6 Drapery
0.68 Bug Screen
-6-.-76--
-7- Drapery
0.68 Bug Screen
0.76
8- Drapery
038 Bug Screen
0.76--23
-T0:0
T0:0
01
10.0
10.0
9 Urapery
0.68 Bug Screen
0.76
10 Drapery
0.68 Bug Screen
0.76
8.0
6.0
-8.0-0.1
8.0
8.0
fl- Drapery
038 Bug Screen
079-
-
-
-
-
T7 Drapery
--M Bug Screen
--M.2.5
10.0
-0.0
0.1
10.0
10.0
1'S Drapery
036 Bug Screen
079,
-
-
-
-
f4 rapery
0:68 ug Screen
079--
-
-
-
T5 Drapery
0:68 Bug Screen
0.76-
-8-.0
6:0
-8-.0
071
8.0
8.0
S Drapery
068 Bug Screen
076-
-
-
-
-
17 Drapery
0.68 Bug Screen
0.76
T8f Drapery
--M Bug Screen
0:76-
-
-
-
-
f9 Drapery
038 Bug Screen
076-
-
-
-
-
2- Grapery
038 Bug Screen
076-
--Yo
-10
-
-
0.0 0.0 0 0.1 4.0 0
W Drapery
038 Bug Screen
-
22 Drapery
0.68 Bug Screen
23 Drapery
0.68 Bug Screen
0.76
24 Drapery
0.68 Bug Screen
0.76
25 Drapery
0.68 Bug Screen
0.76
26 Drapery
0.68 Bug Screen
0.76
Run Initiation Time: 07/21/00 13:32:02 Run Code: 964211522
EnergyPro 2.1 By Ener Soft User Number: 3665 Job Number: 901.13A Page:9 of 32
- Computer Method Summary (Part 3 of 3) C -2R
Haber Residence (Existing + Addition) 7/21/00
ro/ec i e a e
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat
Type (sf) (in.) Cap.
691
3_50
28
54
3.50
28
140
320
28
219
3.50
28
PERIMETER LOSSES
Cond. Form 3 Reference
0_98 n/a
0.98 n/a
0.98 n/a
0.98 n/a
0.98 n/a
Inside Location
R -Val. Comments
U txisung mouse i ciao on cjraae
2 Existing House / Slab on Grade
0 Addition to Bedroom's / Slab on Grade
2 Addition to Bedroom's / Slab on Grade
0 Office / Slab on Grade
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Central Furnace 78%AFUE Ducts in Attic 4.2 Setback Existing Heat/Cool Units
Split Heat Pump 6.8 HSPF Ducts in Attic 4.2 Setback Office Unit
• Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
Split Air Conditioner
Split Heat Pump
WATER HEATING SYSTEMS
Water Heater
System Name
American G52-50T383NV
Minimum Duct
Efficiency Location
(SEER) (attic, etc,)
10.0 SEER Ducts in Attic
10.2 SEER Ducts in Attic
Duct Thermostat Location /
R -Value Type Comments
4.2 Setback Existing Heat/Cool Units
4.2 Setback Office Unit
Ratedl Tank
Water Heater Distribution # in Input Cap.
Type Type Syst. (Btu/hr) (gal)
Small Gas Recirc/Time+Temp 1 38,000
Energy Fact! 1 Tank Insul.
or Recovery Standby R -Value
Efficiency Loss (%) Ext.
50 0.62 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 07/21/00 13:32:02 Run Code: 964211522
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:10 of 32
F2
Insulation
Type
Length
Factor
R -Val.
Depth
Location / Comments
Slab Perimeter
192
0.76
0.0
0
Existing House
Slab Perimeter
103
0.76
0.0
0
Existing House
Slab Perimeter
11
0.76
0.0
0
Addition to Bedroom's
Slab Perimeter
33
0.76
0.0
0
Addition to Bedroom's
Slab Perimeter
33
0.76
0.0
0
Office
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Central Furnace 78%AFUE Ducts in Attic 4.2 Setback Existing Heat/Cool Units
Split Heat Pump 6.8 HSPF Ducts in Attic 4.2 Setback Office Unit
• Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
Split Air Conditioner
Split Heat Pump
WATER HEATING SYSTEMS
Water Heater
System Name
American G52-50T383NV
Minimum Duct
Efficiency Location
(SEER) (attic, etc,)
10.0 SEER Ducts in Attic
10.2 SEER Ducts in Attic
Duct Thermostat Location /
R -Value Type Comments
4.2 Setback Existing Heat/Cool Units
4.2 Setback Office Unit
Ratedl Tank
Water Heater Distribution # in Input Cap.
Type Type Syst. (Btu/hr) (gal)
Small Gas Recirc/Time+Temp 1 38,000
Energy Fact! 1 Tank Insul.
or Recovery Standby R -Value
Efficiency Loss (%) Ext.
50 0.62 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 07/21/00 13:32:02 Run Code: 964211522
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:10 of 32
Computer Method Summary. (Addendum) C2 -R
Haber Residence (Existing + Addition) 7/21/00
. Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
•
0
+ ..............w 4.. Y -- an` arca — J. ----
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2072 sqft Exposed Slab Floor, 3.50" thick at Existing House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 691 sqft Covered Slab Floor, 3.50" thick at Existing House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 54 sqft Exposed Slab Floor, 3.50" thick at Addition to Bedroom's
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 140 sqft Covered Slab Floor, 3.50" thick at Addition to Bedroom's
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 219 sqft Exposed Slab Floor, 3.50" thick at Office
HERS Required Verification
These features must be confirmed and/or testedby a certified HERS rater under the supervision of a CEC approved HERS
Run InitiationTime: un Code: 964211522
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:11 of 32
INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R
• Si a Address Permit Number
An installation certificate is required to be posted at the building site or made available for all appropriate inspections.
(The information provided on this form is required; however, use of this form to provide the information is optional.)
After completion of final inspection, a copy must be provided to the building department (upon request) and the
building owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heating Equipment
Equip. # of Efficiency' Duct Duct or Heating Heating
Type (pkg., CEC Certified Mfr Name Identical (AFUE, etc.) Location Piping Load Capacity
heat pump) & Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr)
Cooling Equipment
Equip. CEC Certified Compressor # of Efficiency' Duct Cooling Cooling
Type (pkg. Unit Mfr Name & Identical (SEER etc.) Location Duct or Load Capacity
heat pump Model Number Systems [>= CF -1 R Va[ue] (attic, etc.) R -Value (Btu/hr) (Btu/hr)
T -reads Greater Than or Equal to.
I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent
to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the
Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate
requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
WATER HEATING SYSTEMS:
CEC Certified Distribution If Recir- # of Rated2 Tank Effi-2 2 External
Heater Mfr Name Type(Std, culation, Identical Input (kW Volume ciencyy Standb Insulation
Type & Model Number Point -o -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (%� R -Value
2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input.
For instantaneous gas water heaters, list Recovery Efficiency and Rated Input.
3 R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58.
Faucets & Shower Heads:
All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111.
I, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to
or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy
Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for
manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: 901.13A Page: 12 of 32
0
INSTALLATION CERTIFICATE (Part 2 of 7) CF -6R
SI a AddressPermit Number
FENESTRATION / GLAZING:
Product U- Product Interior or
Value 1 SHGC1 Exteror Shading
(=<CF -1 R (=< CF -1 R # of Quantity Square Device or Comments/
Manufacturer/Brand Name value)2 valuey Panes (Optional) Feet Overhang Special Features
GROUP LIKE PRODUCTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
1. Manufactured Fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 116 of the Energy Efficiency Standards.
2. Installed U -value must be less than or equal to values from CF -11R. Installed SHGC must be less than or equal to values from CF -1 R, or a shading device (interior, exterior or overhang) is
installed as specified on the CF -1 R. Alternatively, installed weighted average U -values for the total fenestration area are less than or equal to values from CF -1 R.
I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2)
is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance (Form CF -1 R)
submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds
the appropriate requirements for manufactured devices (from Part 6), where applicable.
Item #s - igna ure, Date
(if applicable)
Item #s Signature, Date
(if applicable)
Item #s Signature, Date
(if applicable)
Installing Subcontractor(Co.Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
OR Window Distributor
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By EnergySoft User Number: 3666 Job Number: 901.13A Page: 13 of 32
INSTALLATION CERTIFICATE (Part 3 of 7) CF -6R
• Site Address Permit Number
DUCT DIAGNOSTICS
This buiding obtained compliance credit for: F� Duct sealing ❑ Duct Area Reduction
ACCA Manual D design and installation
CREDIT FOR REDUCED DUCT SURFACE
AREA OR LOCATION
Duct Location' Exterior Measured
Surface Area Exterior Surface
(CFAR) Area
❑ Attic
❑ Crawlspace
❑ Basement
Fj Other
Total
ACCA Design
El Duct Design on Plans
❑ Installed duct diameters match plans
❑ TXV installed
❑ Access to:TXV valve (if installed)
E No TXV, Fan air flow (CFM)_
Duct Leakage Measured
Measured leakage (CFM)
HVAC fan air flow (CFM)_
(measured or calculated as
'Ignore ducts in
CFM = 0.7 x Afloor for CZ 8 through 15
conditioned space.
Only a check is
CFM = 0.5 x Afloor for CZ 1 through 7 & 16
required for location,
or, it the equipment size is known, the larger of 1 or 2.
credit.
1. ❑CFM = 400 x Cooling Capacity in Tons or
2. ❑ CFM = 21.7 x Heating Capacity in Thousands of Btu per hour)
Leakage divided by HVAC Fan air flow (must be =< 0.06)
For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed:
❑ Duct Fan Pressurization at rough - in measured leakage CFM CHECK AFTER FINISHING WALL:
Pressure Pan Test ❑ House pressuezation test Fj Visual Inspection of Duct Connections
Provide Follow-up Test Results or Inspection Results on a Separate Page
This certifies that the ducts surface area and duct locations were verified.
When compliance credit is claimed for duct surface area reducitons and duct location improvements beyond those covered by default
assumptions, builder employees or subcontractors shall certify that they have verified that the duct surface area and locations match those
on the plans and shall indicate the duct surface area in each duct location on the CF6R.
This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with
the requirements for. compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.]
Tests Signature, Daten� stalling uContractorco. ame
Performed OR General ontractor ( o. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 14 of 32
INSTALLATION CERTIFICATE (Part 4 of 7) CF -6R
•
-Site Address Permit Number
BUILDING ENVELOPE LEAKAGE DIAGNOSTICS
This buiding obtained compliance credit for: F-] Envelope sealing using diagnostic testing (CF -1R)
Needed for Compliance Measured Blowerdoor Test
(from CF -1 R) Results
-Building Envelope Leakage (CFM @ 50 Pa)
-Leakage level equivalent to an SLA of 3.0 from CF -1 R
-Minimum Building Leakage equivalent to an SLA of 1.5
from CF -1 R (CFM @ 50 Pa)
❑ Yes ❑ No Is design infiltration less than the SLA 3.0 equivalant (from CF -1 R)?
❑ Yes ❑ No Is mechanical ventilation installed? (Required if design is less than 3.0 SLA)
❑ Yes ❑ No Is measured leakage (without fans operating) less than minimum in the above Table (1.5 SLA from CF -1 R)?
❑ Yes 0 No Is mechanical supply ventilation installed to assure house pressure does not go below minus 5 Pascal relative to
outside ambient with all exhaust fans operating?
Mechanical Ventilation - Fill in Table if mechanical ventilation is installed
Used for Compliance
(from CF -1 R)
Continuous Mechanical Ventilation (CFM
-Continuous Mechanical Supply Ventilation
(CFM) Required to maintain -5 Pa if building
envelope leakage is less than minimum (see
above)
-Total Power Consumption of Continuous
Mechanical Ventilation (Watts) 2
❑ This certifies that the building leakage was verified.
Measured
Actual
When compliance credit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall
certify that they have verified that the building leakage level matches that used for compliance on the CF -6R and shall document the
infiltration levels required for compliance and the tested infiltration values on the CF -6R..
Fj This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with
the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.]
Tests igna ure, Date - nl sU mg Subcontractor(Co.Name)
Performed OR General Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
1. When mechanical ventilation is required, CFM less than 0.047 CFM per square foot of conditioned floor area indicates failure to achieve compliance
2. As determined from label on fan or manufacturers literature.
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:15 of 32
INSTALLATION CERTIFICATE (Part 5 of 7) CF -6R
•Slte Address Permif Dumber
The following is an explanation of many of the input values required on this form:
HVAC SYSTEMS
Heating Equipment Type must be one of the following:
Furnace:
Gas (including Liquefied Petroleum Gases) or oil -fired central furnace & space heater
Boiler:
Gas or oil -fired boiler
PckgHeatPump:
Packaged central heat pump
SplitHeatPump:
Split central heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (>=65,000 Btu/hr output)
Electric:
Electric resistance heating (fixed HSPF = 3.413); radiant electric resistance
(fixed HSPF = 3.55)
CombinedHydro:
I Reference water heater under water heating systems below
-CEC Certified Manufacturer Make & Model Number from applicable Commission approved appliance directory.
"# of Identical Systems" is for those systems with the same efficiency, duct location, duct R -Value and capacity.
-Efficiency from applicable Commission certified appliance directory.
-Duct Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none.
-Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data.
-Heating/Cooling Load refer to Commission approved load calculation procedure.
-Heating/Cooling Equipment Capacity from the applicable Commission certified appliance directory. Note: location
relevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's literature).
1]
Cooling Equipment Type must be one of the following:
SplitAirCond:
Split system air conditioner
PckgAirCond:
Packaged air conditioner
SplitHeatPump:
Split system heat pump
PckgHeatPump:
Packaged heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (>=65,000 Btu/hr output). Substitute EER for
SEER when SEER is not available.
RoomAirCond:
Room air conditioner. Minimum SEER varies*
LrgPkgAirCond:
Large packaged air conditioner (>=65,000 Btu/hr output). Substitute EER for
SEER when SEER is not available.
EvapDirect:
Direct evaporative cooling system. For compliance calculation
purposes, fixed values:
SEER = 11.0; duct location = attic;
duct insulation R -value = 4.2
Evapindirect:
Indirect evaporative cooling system. For compliance calculation
purposes, fixed values:
SEER = 13.0; duct location = attic;
duct insulation R -value = 4.2
*Refer to California Energy Commission (CEC) publication Appliance Efficiency Regulations, P400-92-029
EnergyPro 2.1 By EnergySoft User Number: 3666 Job Number: 901.13A Page: 16 of 32
0
9
INSTALLATION CERTIFICATE (Part 6 of 7) CF -6R
Site Address Permit Number
The following is an explanation of many of the input values required on this form:
WATER HEATING SYSTEMS
Distribution Systems: 'Refer to Residential Manual for more details.
Standard:
Standard - Supply prssure based system, no pumps
Pipe Insulation:
Pipe Insulation on all 3/4 -inch pipes
POU/HWR:
Point of Use/Hot Water Recovery System
Recirc/NoControl:
Recirculation loop with no controls
Recirc/Timer:
Recirculation loop with a timer
Recirc/Temp:
Recirculation loop with temperature control
Recirc/Time + Temp:
Recirculation loop with a timer and temperature control
Recirc/Demand:
I Recirculation loop with demand control
Water Heater Type
Storage Gas, Oil or Electric
Heat Pump
Instantaneous Gas
Instantaneous Electric
Large Storage Gas
Indirect Gas (Boiler)
Information Needed
Energy Factor
Recovery Efficiency
Standby Loss
Rated Input
Yes
No
No
No
Yes
No
No
No
No
Yes
No
No
Yes
No
No
No
No
Yes
Yes
Yes
No
Yes (AFUE)
No
Yes
FENESTRATION / GLAZING
Fenestration:
Windows, sliding glass doors, french doors, skylights, garden windows, and
any door with more than one square foot of glass
Operator Type;
Slider, hinged,, fixed
U -Value:
Installed U -Value must be less than or equal to value from CF -1 R
OR
Installed weighted average U -Value for the total fenestration area
is less than or equal to value from CF -1 R
SHGC:
IInnsstalled SHGC must be less than or equal to value from CF -1 R
Installed SHGC for the total fenestration area is less than or equal to value
from CF -1 R
OR
An interior shading device, overhang, or exterior shading device is installed
consistent with the CF -1 R
ShadingDevice:
Include when the building complied using an interior shading device: blinds,
opaque roller shades, blinds (do not list draperies), an exterior shading
device: woven sunscreen, louvered sunscreen, low sun angle sunscreen,
roll -down awning, roll -down blinds or slats (do not list bug screen), or an
overhang (include depth in feet)
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 17 of 32
INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R
10 Site Address Permit Number
•
The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3
of 6j:
TYPE OF CREDIT
Refer to Residential Manual Chapters 4 and 5 for more details:
Reduced Duct Surface
Calculated as the outside area of the duct. Areas must be measured and
Area:
verified by HERS rater.
Improved Duct Location:
Supply duct located in other than attic, as verified by location of registers
(does not require HERS rater verification).
Catastrophic Leakage:
Pressure pan test reading must be less than 1.5 Pascal at a house pressure
of 25 Pascal.
TXV:
Access cover required to facilitate verification.
Infiltration Reduction:
Infiltration is measured without mechanical ventilation operating.
Mechanical ventilation is required for very tight house construction when
credits for infiltration reduction using diagnostic testing are beng used for
achieving compliance. These very tight houses are defined as those with
SLA of less than 1.5. The compliance documentation (CF -1 R) will contain
the measured CFM target value from a blower door test at 50 Pascal
pressure difference that represents this SLA of 1.5. Mechanical ventilation
is also required if the builder chooses to design the building to use
mechanical ventilation and claims a credit for infiltration below an SLA of
3.0. The compliance documentation (CF -1 R) will contain the measured
CFM target value that represents this 3.0 SLA. If the builder claims credit
in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and
the actual measured SLA is 1.5 or greater, then mechanical ventilation is
not required. If the SLA in this case were below 1.5, then mitigation (such
as mechanical ventilation) would be required.
EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: 901.13A Page: 18 of 32
0
iVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Haber Residence (Existing + Addition) 7/21/00
SYSTEM NAME FLOOR AREA
Existing Heat/Cool Units 2,957
Number of Systems
2
Heating System
Output per System
80,000
Total Output (Btuh)
160,000
Output (Btuh/sqft)
54.1
Cooling System
Output per System
46,000
Total Output (Btuh)
92,000
Total Output (Tons)
7.7
Total Output (Btuh/sqft)
31.1
Total Output (sgft/Ton)
385.7
Air System
CFM per System
1,740
Airflow (cfm)
3,480
Airflow (cfm/sqft)
1.18
Airflow (cfm/Ton)
453.9
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 OF
Outside
0 cfm
69.0 OF
11.0 / 77.4 of
OutsideA
0 cfm
79.1/68.9 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
6,060
78,960
7,320
1,678
73,613
0
3,948
3,681
0
0
0
0
0
0
0
0
0
3,948
3,681
86,856 7,320 80,974
Existing Heat/Cool Units 53,238 34,391 160,000
Total Adjusted System Output 53,238 34,391 160,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
69.0 of 69.0 OF 111.9 OF
0,.
Supply Fan Heating Coil
3480 cfm
m
Supply Air Ducts
110.9 of
ROOMS
70.0 OF
Return Air Ducts E I
79.1 / 68.9 of 79.1 / 68.9 of. 64.8 / 63.9 of
%
Supply Fan
3480 cfm
Cooling Coil
k Return Air Ducts q
Supply Air Ducts
65.8164.2 of
62.5% R.H. ROOMS
78.0 / 68.6 OF
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:19 of 32 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Haber Residence (Existing + Addition) 7/21/00
• SYSTEM NAME FLOOR AREA
Office Unit 219
•
Number of Systems
1
Heating System
Output per System
13,500
Total Output (Btuh)
13,500
Output (Btuh/sgft)
61.6
Cooling System
Output per System
12,900
Total Output (Btuh)
12,900
Total Output (Tons)
1.1
Total Output (Btuh/sgft)
58.9
Total Output (sqf rron)
203.7
Air System
CFM per System
855
Airflow (cfm)
855
Airflow (cfm/sgft)
3.90
Airflow (cfm/Ton)
795.3
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 of 69.7 of
Outside Air
0 cfm
Supply Fan
855 cfm
69.7 OF
11.0 / 77.4 of
Outside
0 cfm
78.4/68.7 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
ICOILHTG.PEAK
CFMISensiblel
639
Latent
1CFM1
Sensible
979
6,843
535
639
6,171
0
342
309
0
0
0
0
0
0
0
0
0
342
309
7,527 535 6,788
MITSUBISHI ELECTRONICS MUH12NN 6,661 5,579 8,879
Total Adjusted System Output 6,661 5,579 8,879
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
69.7 of. 79.3 of
Heating Coil
m le
78.4 / 68.7 of 78.4 / 68.7 of
IFI--�
k Return Air Ducts 14
71.1 / 66.3 of
Supply Fan Cooling Coil
855 cfm
Return Air r)ucts
Supply Air Ducts
79.0 of
ROOMS
70.0 of
Supply Air Ducts
71.5 / 66.4 of
62.4% R.H. ROOMS
78.0 / 68.6 of
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:20 of 32 1
0
ROOM LOAD SUMMARY 771
PROJECT NAME
DATE
Haber Residence (Existing + Addition)
7/21/00
SYSTEM A
FLOOR AREA
Existing Heat/Cool Units
2,957
IROOM LOA SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Existing House
xis mg House
1
5,221
68,020
6,908
5,221
68,020
6,908
1,485
65,133
Addition to Bedroom's
Aagi ion to e room s1
840
10,940
411
840
10,940
411
193
8,480
PAGE TOTAL 1 6,060 78,960 7,320 1,678 73,613
TOTAL 1 6,060 78,960 7,320 1,678 73,613
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:21 of 32
ROOM LOAD SUMMARY
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:22 of 32
PROJECT NAME
Haber Residence (Existing + Addition)
DATE
7/21/00
.SYSTEM
Office Unit
FLOOR AREA
219
IROOM LOAD SUMMARY
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Office
Office
1
979
6,843
535
979
6,843
535
639
6,171
PAGE TOTAL 979 6,843 535 639 6,171
TOTAL 1979 6,843 535 639 6,171
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:22 of 32
ROOM HEATING PEAK LOADS
Project Title Date
• Haber Residence (Existing + Addition) 17/21/00
Room Information Design Conditions
Room Name Ebsting Housel Time of Peak .tan 12 am
Floor Area 2,763 Outdoor Dry Bulb Temperature 26 OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 43,845
Infiltration: 1.00 x 1.072 x 2,763 x 9 9.90 x 1.00 / 60] x 0 = 21 288
c e u e r Sensible Area Calling Height ACH &T
Fraction
lei TOTAL HOURLY HEAT LOSS FOR ROOM 65,133
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 23 of 32
2,747.0
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0341
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
4,116
16.0
0.9400
44.0
662
1,448.6
0.0655
44.0
4,172
42.3
0.3872
44.0
721
336.0
0.8500
44.0
12,566
256.6
0.7200
44.0
8,130
2.0
0.7200
44.0
63
7.5
0.8700
44.0
287
perimeter 295.0
44.5
13,128
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 43,845
Infiltration: 1.00 x 1.072 x 2,763 x 9 9.90 x 1.00 / 60] x 0 = 21 288
c e u e r Sensible Area Calling Height ACH &T
Fraction
lei TOTAL HOURLY HEAT LOSS FOR ROOM 65,133
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 23 of 32
ROOM HEATING PEAK LOADS
Project Title
Haber Residence (Existing + Addition)
Date
7/21/00
Room Information Design Conditions
Room Name Addition to Bedroom's
Time of Peak Jan 12 am
Floor Area 194
Outdoor Dry Bulb Temperature 26°F
Indoor Dry Bulb Temperature 70°F
0.0280
•
Conduction
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Double Mtl Uncoated Default
Double Mtl Uncoated Default
Area
X
x
X
X
X
X
X
x
X
X
x
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
x
x
x
x
x
x
x
X
x
x
X
. U -Value
X
X
X
X
X
x
X
x
X
X
X
X
X
x
X
X
X
x
x
x
x
x
X
x
x
x
X
x
x
x
x
x
x
x
x
X
X
X
X
AT of
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
194.0
0.0280
44.0
239
194.6
0.0592
44.0
507
18.7
0.7200
44.0
592
106.7
0.8500
44.0
3,991
perimeter 44.0
44.5
1,958
Items shown with an asterisk (-) denote conduction through an interior surface to another room. Page Total: 7,287
Infiltration: 1.00 x 1.072 x 194 x 7.82 x 1.00 / 60 x 0 = 1,193
5C11801.118 r ens a rea Ceiling Height pT
Fraction
101 TOTAL HOURLY HEAT LOSS FOR ROOM 8,480
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 24 of 32
r
ROOM HEATING PEAK LOADS
Project Title
Haber Residence (Existing + Addition)
Date
17/21/00
Room Information Design Conditions
Room Name office
Time of Peak Jan 12 am
Floor Area 219
Outdoor Dry Bulb Temperature 26 OF
Indoor Dry Bulb Temperature 70 OF
185.7
Conduction
A- 11 %1-1.... --o-
219.0
—o-
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 4,535
Infiltration: [ 1.00 X 1.072 X 219 x 9.50 X 1.00 / 60 X
c e u eAir sensible Area Ceiling Height pT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 6,171
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 25 of 32
219.0
x
X
X
X
x
X
X
x
X
X
x
X
X
x
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
0.0280
x
X
X
X
X
X
X
X
X
X
x
X
X
x
x
X
X
x
X
X
X
X
x
x
X
X
X
X
x
X
X
X
X
X
X
X
x
X
X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
270
185.7
0.0592
44.0
484
20.0
0.3872
44.0
341
62.2
0.7200
44.0
1,972
perimeter 33.0
44.5
1,468
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 4,535
Infiltration: [ 1.00 X 1.072 X 219 x 9.50 X 1.00 / 60 X
c e u eAir sensible Area Ceiling Height pT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 6,171
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 25 of 32
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing + Addition) 7/21/00
Project Title Date
Room Name Existing House
Design Indoor Dry Bulb Temperature: 780F
Design Outdoor Dry Bulb Temperature: 112°F
Design Temperature Difference: 340 F
Conduction
R-30 Roof (R.30.2x12.16)
Double Mtl Tinted Default
R-19 Wall (W.19.2x6.16)
Solid Wood Door
Double Mtl Uncoated Default
Double Mtl Uncoated Default
Glass Block
Double MU Uncoated Default
Area
X
X
X
X
X
X
X
x
X
U -Value
X
X
X
X
X
X
X
X
X
DETD 1
2,747.0
0.0341
51.0
16.0
0.9400
34.0
1,448.6
0.0655
30.6
42.3
0.3872
30.6
336.0
0.8500
34.0
256.6
0.7200
34.0
2.0
0.7200
34.0
7.5
0.8700
34.0
340
0.0
9.8
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
Skylight
(Skylight)
1
2
3
(Northeast)
(Northeast)
(Northeast)
4
5
(Northeast)
(Northeast)
10
(Southeast)
11
(Southeast)
12
(Southeast)
13
(Southeast)
Page Total
SC
Btu/hr
4,771
511
2,901
501
9,710
6,282
49
= 222
24,948
Btu/hr
0.0
X+
X+
x+
x+
xdi
x+
x+
X+
X+
x+
+
16.0
X
X
X
X
X
X
x
x
X
x
152)
X
X
X
X
x
X
X
X
x
x
0.690
=
=
=
=
=
=
=
=
-_
=
1,677
0.0
80.0
48)
0.720
2,765
0.0
18.0
48)
0.727
628
0.0
14.1
48)
0.727
493
0.0
9.8
48)
0.727
340
0.0
9.8
48)
0.727
340
0.0
80.0
62)
0.720
3,572
25.0
0.0
62)
0.727
272
0.0
48.0
6)
0.727
2,162
48.0
1 0.0
62)
0.720
518
Sched. Page Total 12,768
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 2,763 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0
Occupants 1.00 x 2,763 X 245 Btuh/OCC. / 250 sgft/occ. = 2,708
Receptacle 1.00 X 2,763 x 0.200 Watts/sgft X 3.413 Btuh/Watt = 1,886
Process 1.00 X 2,763 X 0.000 Watts/sqft x 3.413 Btuh[Watt = 0
Infiltration:L:Z1.00 X 1.072 X 2,763 x 9.80 X 1.00 60] 34 = 16,450
u e A r ens a Area ell ng e g ICC p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 68,020
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 2,763 X 155 Btuh/OCC. / 250 sgft/occ.
Receptacle 1.00 x 2,763 X 0.000 Watts/sqft xJ 3.41 Btuh/Watt = 0
Process 1.00 x 2,763 x 0.000 Watts/sgft x I 3.413 Btuh/Watt = 0
Infiltration: [ 1.00 X 4,806 X 2,763 X 9.80 X 1.00 60] 0.00240
FrAir= 5,195
e u e a en rea Cer nl g Helgh C ZSyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,908
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 26 of 32
P
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing + Addition) 7/21/00
Project Title Date
Room Name Existing House
Design Indoor Dry Bulb Temperature: 78°F
Design'Outdoor Dry Bulb Temperature: 112°F
Design Temperature Difference: 340F
Conduction
Area U -Value
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
14
(Southwest)
15
(Southwest)
16
(Southwest)
17
(Southwest)
18
(Southwest)
19
(Southwest)
20
(Northwest)
21
(Northwest)
22
(Northwest)
1
24.0
DETD1
Page Total
SC
Btu/hr
Btu/hr
0.0
x
X1
X
x
X
x
x
x
X
X
1
+
+
+
+
+
+
+
+
+7.5
+
80.0
X
X
X
X
x
X
X
x
x
X
62)
X
X
x
X
X
X
x
X
) X
0.720
=
=
=
=
=
=
=
=
-_
=
3,572
25.0
0.0
62)
0.727
272
0.0
1
24.0
62)
0.727
1,081
0.0
1
10.0
62)
0.727
451
48.0
1
0.0
62)
0.720
518
0.0
1
48.0
62)
0.727
2,162
0.0
1
2.0
48)
0.757
73
0.0
1
25.0
48)
0.727
872
0.0
1
F::I)x
0.720
259
Sched. Page Total x,261
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 2,763 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Occupants 1.00 x 2,763 X 245 Btuh/OCC. / 250 sqft/occ. = 2,708
Receptacle 1.00 X 2,763 x 0.200 Watts/sgft X 3.413 Btuh/Watt = 1,886
Process 1.00 x 2,763 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: 1.00 x 1.072 X 2,763 x g g80 x 1.00 / 60] 0 34 = 16,450
Lceue r ens a Area ng,-
jr,
�ilTA
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 68,020
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 2,763 x 155 Btuh/occ. / 250 sgftloCC. = 1,713
Receptacle 1.00 X 2,763 x 0.000 Watts/sgft X 3.41J,Btuh/Watt = 0
Process 1.00 X 2,763 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: 1.00 x E 4,8061 XX g 9.90 X 60] Q0.00240 = 5,195
ceue r Latent rea CeMn e
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,908
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 27 of 32
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing + Addition) 7/21/00
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Double Mtl Uncoated Default
Double Mtl Uncoated Default
Area
X
X
X
X
X
X
X
x
X
U -Value
194.0
0.0280
194.6
0.0592
18.7
0.7200
106.7
0.8500
3,084
1
Al
53.4
62)
0.720
2,382
0.0
1
5.3
62)
Addition to Bedroom's
78OF
112°F
340E
X
X
X
X
X
X
X
X
X
DETD 1
=
=
=
=
=
=
=
=
=
Btu/hr
51.0
277
30.6
353
34.0
457
34.0
3,084
1
Al
53.4
62)
0.720
2,382
0.0
1
5.3
62)
0.727
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF
A
(Northeast)
B
(Southeast)
C
(Southeast)
D
(Southeast)
E
(Southeast)
279
0.0
1
Al
53.4
62)
0.720
2,382
0.0
1
5.3
Page Total x,171
SC Btu/hr
0.0
x8)
X
X
x
X
X
x
x
x
X
+
+
+
+
+
+
+
+
+
X
X
X
X
X
X
X
X
X
X
x
X
X
X
)X
)X
)X
)X
)X
0.727
=
=
=
=
=
=
=
=
=
279
0.0
1
Al
53.4
62)
0.720
2,382
0.0
1
5.3
62)
0.727
241
0.0
5.3
62)
0.727
241
0.0
1
53.4
62)
0.720
2,382
Sched. Page Total 5,525
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 194 X 0.000 Watts/sqft X 3.413 Btuh/Watt = 0
Occupants 1.00 x 194 X 245 Btuh/OCC. / 250 sgft/occ. = 190
Receptacle 1.00 X 194 X 0.200 Watts/sgft X 3.413 Btuh[Watt = 132
Process 1.00 x 194 x 0.000 Watts/sgft X 3.413 Btuh/Waft = 0
Infiltration: 1.0o X 1.072 X 194 X g 9g2 X 1.00 60] Q 34 = 922
ceue r ens a Area e n e
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,940
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 194 X 155 Btuh/occ. / 250 sgft/occ. = 120
Receptacle 1.00 x 194 X 0.000 Watts/sqft X 1 3.41 Btuh/Watt = 0
Process 1.00 X 194 X 0.000 Watts/sqft X 1 3.41 Btuh/Watt = 0
Infiltration: C 1.001 x 4,806 x 1g4 x 7.82 x 1.00 60] 0.00240 = 291
ceue r Latent Area a ng e g Qyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 411
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page: 28 of 32
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Haber Residence (Existing + Addition) 7/21/00
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Solid Wood Door
Double Mtl Uncoated Default
Area
X
X
X
X
X
X
X
x
X
U -Value
219.0
0
185.7
0
20.0
0
62.2
0
642
(Southwest)
1
48.0
62)X
0.727
2,162
DETD 1
X 51.0
X 30.6
X 30.6
X 34.0
X
X
X
X
X
1. Design Equivalent Temperature Difference (DETD) Page Total
Items shown with an asterisk (*) denote conduction thruahh d interior surfaceUnshat99 another room.
ed
Solar Gain Orientation Area SGF Area SGF SC
F
G
Office
78°F
112°F
340E
Btu/hr
313
337
237
1,524
2,410
Btu/hr
(Southeast)
( 0.0
( 0.0
(
(
(
(
(
(
(
(
x
X
X
x
X
X
x
x
X
x
1
+
+
+
+
+
+
+
+
+
+
14.2
x
x
x
X
X
X
X
X
X
X
62)
x
)X
)X
)X
)X
)X
)X
)X
)X
0.727
=
=
=
=
=
=
=
=
=
=
642
(Southwest)
1
48.0
62)X
0.727
2,162
Sched. Page Total 2,8oa
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 219 X 0.000 Watts/sqft X 3.41 Btuh/Watt = 0
Occupants 1.00 X 219 x 245 Btuh/occ. / 250 sqft/occ. = 215
Receptacle 1.00 X 219 X 0.200 Watts/sqft x 3.413 Btuh/Watt = 149
Process 1.00 X 219 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0
Infiltration: 1.00 x[=072 x 219 x 9.50 x 1.00 / 60] 34 = 1,2641
ceueAir Sensitile rea a ng e g p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,843
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 219 x 155 Btuh/OCC. / 250 sqft/occ. = 136
Receptacle 1.00 x 219 x 0.000 Watts/sqft x I 3.41J,Btuh/Watt = 0
Process 1.00 x 219 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0
Infiltration:[ 1.00 x 4,806 X 21 X 9.50 x 1.00 / 60] 0.00240 = 399
ceue r Latent Area ell ng e g c pyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 535
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.13A Page:29 of 32
SMALL AREA COOLING AND HEATING MADE SIMPLE.
The I feel Remote Controller
At Mitsubishi we believe that
advancement in design is often a
matter of simplification. This wireless
LCD remote controller is a superb
p oo example. It lets the user adjust the
temperature instantly with one tap of
a button. And the command
language couldn't be easier. There's
a button for TOO COOL and TOO
WARM.
• Operation Mode Setting (1 Feel, Cool, Dry, Heat).
• Computerized dehumidification in the dry mode
• Three Speed or Automatic Fan Control
• Twenty -Four Hour On/Off Timer
• Vane Control (automatically adjusts angle)
• Self -Diagnostic Display
*Outdoor Compressor Unit
Mr. Slim outdoor compressor units are
extremely efficient and reliable and true space -
savers.
These models can be installed up to sixty
five feet away from the indoor unit. They
connect simply through a single three inch
opening in the wall or ceiling. No ductwork or
remodeling is necessary.
0
Air Flow
This series provides whisper -quiet operation
with airflow direction adjustments in both
vertical and horizontal directions.
Auto Cooling Mode
A continuous airflow from a horizontal vane
is the most efficient arrangement for air
conditioning to reach an ideal temperature in
the shortest time.
Remote Control
Using the remote controller you can select
from five different vertical airflow settings to
match the room layout and the location of
people.
Swing Mode
Swing mode ensures that a natural,
comfortable flow of air reaches every corner of
the room. Unnecessary cooling is avoided,
therefore contributing to economical operation.
The vent cover closes automatically when the
unit is turned off, leaving a sleek unit that is
pleasing to the eye.
Simplified Installation
Mr. Slim's streamlined designs make indoor
units adaptable to an almost infinite variety of
room configurations. They're simple to mount,
and they require a minimum of wiring. Naturally
they're not only efficient but whisper -quiet, too.
You'll hardly hear them running.
�•
Ar. S�° M SERIES nus CONDITIONERS
AND HEIR PUMPS
,6
MS1.7NN
a
Cooling capacity 16,.100 BTU/h
SEER: 10.2
Dimensions: W:39-15/16" D:Z-1/2"' H:12-5/8"•
Floor-. Standing Air Conditioners
� Warranty
Mitsubishi is so confident of the reliability of Mr. Slim® Systems that we offer a six year
warranty on the compressor.. and a one year warranty on all other parts.
MS09NW
r -.
Cooling capacity: 8,500 BTU/h.
ti's
SEER: 10:2`
Dimensions::W:32-1/16": D:7-3/16".
HA 0'-43/16"
MS12NN
Nff12811:
K'
Cooling capacity: 12; 600: BTU/h
Y of
SEER:11.3
MF1'2EN ";"°
i•
. Dimensions:: V1l 39-1'5/16"=_ D.7-1'/2"
H:12-5/8"
C'oolinca aci
9 . P tY 12 000 BTU/h .
,
SEER 10:3
MS1:5NN
Dimensions W:36 =1-/4 D':8-1/8" H:23-7/16"'"
Cooling: capacity 14,600 BTU/hc
SEER,: -,10.5
' MF16EN
..;.
Dimensions: W 39=15/16,',D:7-1`/2'
H.:12:-5/8" ,
Cooling: capa6ity: 14,500,BTU/h-
SEER 40.0-
f
Dimensions: W:36-1/4" D':8=1'/8,'- H:23-7/16"
HPiB Pum
MSHI2NN,_
. ?�
p S
Cooling capacity. 12,900 BTU/h
r
4
;
t
SEER: 10.2
Heating capacity
f
n
1:3;500 BT li
HSPF`.6.8,
Dimensions: W:39-15/1:6", D:7-1/2" HA2 -5/8"
J`
IVIS H1
'
Cooling capacity.. 14,600 BTU/h
SEER.10.7
r
MSH09NW
Heating: capacity: 14;800. BTU/h;.
HSPF:: 6.8 =
MSH09NW
Dimensions: W:39-15/16" D:7-1/2".' H,12 -5/8 -
Cooling capacity: 8,800BTU/h '
.
SEER: 10.0 -:
MSH17NN
y ;
Heating capacity:. 10,500 BTU/h
Cooling capacity:.16,200 BTU/h
HSPF:6.8
SEER: 10.4
Dimensions: W:32-1/16"• D,7-3/16"
H:1043/16"
' Heating capacity: 17,200 BTU/h
HSPF: 6.8
.;
Dimensions: W:39-15616 'r D:7-1/2"' HA2-5/8"'
Q
� Warranty
Mitsubishi is so confident of the reliability of Mr. Slim® Systems that we offer a six year
warranty on the compressor.. and a one year warranty on all other parts.
ITEM
MS09NW
MS12NN
MS15NN
MS17NN
MSH09NW
MSH12NN
MSHI5NN
MSH17NN
Capacity
Cooling 'BTU/h
8,500
12,600
14,600
16.100
8,800
12,900
14,600
16,200
Heating 47° 'BTU/h - - - - 10 500 13.500 14 800
17,200
Power
Consumption
Cooling '1 W
840
1,130
1,400
1,600
890
1,310
1,380
1,580
Heating '1 W - - - 890 1,250 1,300
1,570
EER Cooling
10.1
11.2
1 10.4
10.1
9.9
9.8
10.6
1 10.3
ER
10.2
11.3
10.5
10.2
10
10.2
10.7
10.4
SPF
-
-
-
Refrigerant Control
6.8
6.8
6.8
6.8
COP 47° '1
-
33-1/2
-
11-7/16
3.5
3.2
3.3
3.2
INDOOR UNIT
MS09NW
MS12NN
MS15NN
MS17NN
MSH09NW
MSH12NN
MSHI5NN
MSH17NN
External Finish
White
White
White
White
I White
White
White
White
Power Supply V. phase, Hz
115 1 60
115 1 60
115, 1 60
115.1.60
115 1 60
115 1 60
115 1 60
115 1 60
Max. Fuze Size time dela A
15
15.
15
15
15
15
15
15
Min. Ampacity
0.5
0.6
0.6
0.7
0.5
0.6
0.6
0.7
Fan Motor F.L.A.
0.37
0.43
0.43
0.51
0.37
0.43
0.43
0.51
Airflow Lo -Hi
Dry CFM
210-265-330
360-395-450
360-395-450
405-440-500
210-265-330
360-395-450
360-395-450 405-440-490
Wet CFM 175-225-280 315-340-390 295-320365 345-375-415 175-225-280 310-340-390 295-320-365 340-370-415
Moisture Removal Pints/h
2.3
3.2
4.7
5.1
1 2.3
3.3
4.7
5.1
Sound Level dB(A)
42
42
42
45
42
42
42
45
Cond. Drain Connection OD in.
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
W in.
Dimensions D in.
H in.
32-1/16
7-3/16
10-13/16
39-15/16
7-1/2
12-5/8
39-15/16
7-1/2
12-5/8
39-15/16
7-1/2
12-5/8
32-1/16
7-3/16
10-13/16
39-15/16
7-1/2
12-5/8
39-15/16
7-1/2
12-5/8
39-15/16
7-1/2
12-5/8
Wei ht
18
31
31
311
18
31
31
31
OUTDOOR UNIT
MU09NW
MU12NN
MU15NN
I MU17NN
I MUH09NW
MUH12NN
MUHI5NN
MUH17NN
External Finish
Munsell 5Y 6.5/1
Munsell 5Y 7/1
Sound Level d6(A)
46
52
52
52
49
53
53
53
Power SUDDIV V phase, Hz
115, 1, 60
208/230 1 60
208/230 1. 60
208/230. 1. 60
115, 1, 60
208/230. 1. 60 208/230. 1 60 208/230. 1 60
Max. Fuse Size time dela A
15
15
20
20
20
15
20
20
Min. Ampacity
14
12
14
15
16
14
14
15
Fan Motor F.L.A.
0.66
0.52
0.52
0.52
0.7
0.52
0.52
0.75
Compressor
Model t e
KH122WES
1 RH167NHDT
RH2O7NHDT
RH231NHDT RH140WGJT
RH189NHDT
RH2O7NHDT RH231NHDT
R.L.A. 10 1 9 10 1 11 1 12 1 10 1 10 11
L.R.A. 37 1 29 35 1 38 1 42 1 35 1 35 38
fri erant Control
Ca ilia
tube
Defrost method
-
-
-
-
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Dimensions
W in.
30-11/16
33-7/16
33-7/16
33-7/16
30-11/16
33-7/16
33-7/16
34-1/4
D in. 10-1/16 11-7/16 11-7/16 11-7/16 10-1/16 11-7/16 11-7/16
11-5/8
H in. 21-1/4 23-13/16 23-13/16 23-13/16 21-1/4 23-13/16 23-13/16
33-1/2
Wei ht lbs.
64
92
92
97
80
99
99
97
REMOTE CONTROLLER
Wireless type
Control Volta e (by built in transformer
DC12V
REFRIGERANT PIPING SIZE
1/4x3/8
1/4x5/8
I 1/4x3/8
1/4x5/8
Note: For units using 208/230 volt the above ratings are at X30 volts.
MODEL
ITEM
MF12EN
MF15EN
OUTDOOR UNIT
ITEM
MF12EN
MF15EN
Cooling Capacity
'1 BTU/h
12,000
14,500
External Finish
Munsell 5Y 6.5/1
Power Consumption '1 W
1,180
1,470
Sound Pressure Level dB(A)
54 54
EER
'1
10.2
9.9
Power Supply V, phase, Hz
230, 1, 60
SEER
10.3
10.0
Max. Fuze Size (time delay) A
15 20
INDOOR UNIT
MF12EN
MF15EN
Min. Ampacity
11 13
External Finish
White
White
-Fan Motor F.L.A.
0.4 0.4
Power Supply V, phase, Hz
Max. Fuse Size (time delay) A
Min. Ampacity
115, 1,60
15 15
0.5 0.5
Compressor
Model (type)
RH167NAB RH2O7NAB
R.L.A.
8 10
L.R.A.
29 r 33
Fan Motor
F.L.A.
0.4
0.4
Refrigerant Control
Capillary tube
Airflow Hi -Med -Lo
Moisture Removal
Dry CFM
Wet CFM
Pints/h
370-340-280 370-340-280
330-300-250 330-300-250
2.4 3.6
Dimensions
W in.
33-1/2
D in.
11-7/16
H in.
23-7/8
and Level
dB(A)
46
47
Wei ht lbs.
99
ond. Drain Connection OD in.
5/8
REMOTE CONTROLLER
Wireless type
Dimensions
W in.
36-1/4
Control Voltage (by built- in transformer) DC12V
D in. 8-1/8 REFRIGERANT'PIPING 'SIZE 1/4, 1/2
H in. 23-7/16 * Pnr qnR vnit nnnlirntinnc rcfcr fn Tnnhnin l A-4
f, f,,,......,- „1,,..u, -„-
Weight lbs. 59 Service Manual for ratings.
DO
0