BRES2015-0418LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Divisio 3 of the Busin ss and Professions Code,
and my License is in full force and effect.
License CI ss: B 027 License No.: 4 7
Date: I Z3 t Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5, by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address:
(760)777-8202
Llc. No.: 684857
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of tVXrk for which this permit is issued.
�% I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and ag, t, if d become subject to the
workers' compensation provisions of Sectio 70 t e r Code, I shall forthwith
comply w/ i thos provisions.
Date: V (� Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the o e ' f ation is correct.
I agree to comply with all city and county ordinances and stat I w rel ting to building
construction, and hereby authorize representatives of this y t en upon the
above -me tione property for inspection purposes.
Date: 1.11731 tJ Signature (Applicant or Agent):
VOICE (760) 777-7125
78-495 CALLE TAMPICO
D
FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253
COMMUNITY DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 11/23/2015
Application Number: BRES2015-0418
I IIIIII ILII I'll IIII
Owner:
Property Address: 56634 RIVIERA
29
LEONOUDAKIS STEPHAN
APN: 762023020
56634 RIVIERA
Application Description: LEONOUDAKIS /ATRIUM EX OSQR
LA QUINTA, CA 92253
Property Zoning:
D
Application Valuation: $15,000.00
'-----�_�
I�'OV232015 r
Applicant:
Contractor:
BOB EDWARDS CONSTRUCTION INCORPORATED
CIT} OFL/i
BOB EDWARDS CONSTRUCTION INCORPORATED
51-455 DESERT CLUB DRIVE
QUINTA
COMMUNITY DEVELOP►!6WDEPARTMENT
51-455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
LA QUINTA, CA 92253
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Divisio 3 of the Busin ss and Professions Code,
and my License is in full force and effect.
License CI ss: B 027 License No.: 4 7
Date: I Z3 t Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5, by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address:
(760)777-8202
Llc. No.: 684857
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of tVXrk for which this permit is issued.
�% I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and ag, t, if d become subject to the
workers' compensation provisions of Sectio 70 t e r Code, I shall forthwith
comply w/ i thos provisions.
Date: V (� Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the o e ' f ation is correct.
I agree to comply with all city and county ordinances and stat I w rel ting to building
construction, and hereby authorize representatives of this y t en upon the
above -me tione property for inspection purposes.
Date: 1.11731 tJ Signature (Applicant or Agent):
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400 .`
0
$62.36
$62.36
11/23/15
PAID 8Y
R HOD
RECEIPT #
MINE=
CL D BY
BOB EDWARDS CONSTRUCTION INCOR
CHECK
R11064
20927
AZA
Mj
y' " DESCRI�PT N
a
ACCOUNT r
QTY
AM
PAID
D '"I'l
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0-
$17.40' .
$17.40 1 1
11/23/15
': � �D BY
M T OD R
R'E3CE�IPT # `
CHE`#
CLTQ BY
BOB EDWARDS CONSTRUCTION INCOR.
CHECK
R11064
20927.
AZA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
10 •3�tfi6'FFF �:'.�'=rCi
PA(DDATE
..
4'ui,`wr,a.si+
M
k
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.'83,
$120.83
11/23/15
�Pq D BY ;R
� ��^>�;�
� �
REEIPT #.
CHECK #
MZB3Y
rye'
SME:T�HOD
AZA
Total Paid for ADDITION: $311.73
$371.73
BOB EDWARDS CONSTRUCTION INCOR
'CHECK
R11064
20927
AZAq��;;
vi'•-�,'7 b.,r b a's. lM'�'�'fp � sidR'i i .,1�1i� AGI
DESCRIPT`ION�
" .-- k�y�}�dQ•i#�r.�"C --
OU�NT _
QTY`
AIAMOl.NT
PAID
AI A -T
r•AC
HOURLY PLANZCHECK - YES
101-0000-42600
ADDITION, FIRST 100 SF PC
_ 101-0000-42600
0'
$171.14
$171.14,
11/23/15
M
RECEI T�# �r R
-=HEK�t#
� CLTD Y
BOB EDWARDS CONSTRUCTION INCOR
CHECK
R11064
20927
AZA
Total Paid for ADDITION: $311.73
$371.73
A�YxDESCRill TION�A'CUNT
MWA
QTY
AMOUNTPAID
-
PAID DATE
HOURLY PLANZCHECK - YES
101-0000-42600
1.25
$87.50
$87.50
11/23/15
P)PAID BY
finely .d`+n .�il8,at c.., n7.•$n3,. SONS= � ,
OD
RECEE P #
CHECK # • ;
CLkTD BY
BOB EDWARDS CONSTRUCTION'INCOR
CHECK
,'.1111064-
20927
AZA
Total Paid for BLDG, CITY STAFF - PER HOUR: °$87.50.
$87.50
�'r 9a j�;DESCRIAIP-[TION
ACO NT
:c:
- QTX:
AMOUNT
P
'PAD
AP�(AID DATE
ak'�a
c
d4�fg
,.
d.
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
11/23/15
PAI�D�BYMET
OD "
RE PTS# :. !, ib
• CHECK #:
CLTD BY4.,
C.Cs...ZStr ..,n`,..tkSci7E:, rt�+}gdA
ak
ells
SiWE•�A f�
CRk
BOB EDWARDS CONSTRUCTION INCOR ,
CHECK
R11064
20927
AZA
Total Paid -for BUILDING STANDARDS ADMINISTRATION BSA:' $1.00„ •
$1.00
lg,DES@RIPTION
ACCOUNT I
QTY
AMOUNT
MISPA�1D .-
PAIDV-DATE'
RESIDENTIAL, FIRST 1j000SF
101-00.00-42403.
0
$145.03 •,
$145.03
11/23/15
w.iliil
,. PAID
BY
MVJMMSE=TSDf,
�v �. _
!RECEIPT#
CHECK#
CLTD BY
BOB EDWARDS CONSTRUCTION`INCOR
CHECK
R11064
20927
AZA
'.GMT ^:.DESCRIPTlONM •4.
AU NT
XMIM ti;
,'Dif6
Q ,. '
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
,_$47.86'
$47.86
11/23/15
9,� A�I�Y ' •
�M ET�D
#
w- .RECEI T #
CCK #
CLTD BY ..
BOB EDWARDS-CONSTRUCTION INCOR ..
CHECK
R11064
20927
AZA
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192:89•.'
$192.89
"^' i+�. '�. -'SSS
Imo'�DESCRIPTION,.
� �Si�'n'C% ., ,�
ACCOUN
�QT1(
:r ...
nAM O NT
fh.
PAID 'a
��.
PAID DATE
APPLIANCE REPAIR/ALTERATION _
101=0000-42402
0•1*,
$12.09 j
$12.09
11/23/15
$h PARD BY
E
METHOD u
,_
RECEIPT #f°
CHEC��K t#''CLTD
BBY
BOB EDWARDS CONSTRUCTION INCOR.
CHECK' ..
R11064
20927
A2A
Description: LEONOUDAKIS /ATRIUM ENCLOSURE
Type: BUILDING, RESIDENTIAL
Subtype: ADDITION Status: APPROVED
Applied: 10/30/2015 SGU
Approved: 11/23/2015 AZA
Parcel No 762023020 Site Address: 56634 RIVIERA LA QUINTA,CA 92253
Subdivision: TR.24801,: -
Block:, Lot: 5
Issued:
Lot Sq Ft: 0
Building,Sq Ft: 0 Zoning:'
Finaled:
Valuation: $15,000.00
Occupancy Type: Construction Type-.
Expired:
No.Buildings:
ngs: 0
No. Stories: 0. No. 'Unites: 'O
JIM JOHNSON
Details: SQ.FT.) W/ (1) SKYLIGHT. CALIFORNIA 2013 BUILDING,,CODES.
11/12/1015
off w
MEXIM,
ON k!
"M 'SW411261'1' W
'.
. ... ....
LET e -
MP
Ty to.
'
NOTE
STEPHANIE GUMPERt.
11/19/2015
11/19/2015
BOB PICKED UP SCHOOL FEE LETTER
PLAN CHECK COMMENTS
CONDITION
FROM CONSULTANT
JIM JOHNSON
11112/2015
11/12/1015
RECEIVED
NOTES
;PLAN CHECK SENT TO
STEPHANIE GUMPERT
10/30/2015
10/30/2015
SENT TO YOUNG. DUE BACK ,11-16-15.
OUTSIDE PC'
EMARKS�:::�:::;�.::::�'::--5�::',...
PLAN CHECKSUBMITTAIL
STEPHANIE GUMPERT
10/30/2015
10/30/2015
RECEIVED
. .. .... .......
SPOKE WITH GABRIEL RIOS. PERMIT IS APPROVED ANDREADY
TELEPHONE CALL
LUIS URIBE
11/ 17/201S
11/17/2015
.
TO BE ISSUED.
Printpri- MnnH;iv Nn%ipmhpr 71 7n1 ?-77-c,:% PM 1 ofd
'
CONDITION
DATC`-'.i
.......
,,:DATE,:
NOTES
CONTACT
::ADDE
EMARKS�:::�:::;�.::::�'::--5�::',...
REQUIRED �ii
P;.,SATISFII
. .. .... .......
Printpri- MnnH;iv Nn%ipmhpr 71 7n1 ?-77-c,:% PM 1 ofd
f
Printorl• Mnnrinv NnvPmhar 71 ?nl S T,)7•S:% PM ofd � DEttii�Y
BOB EDWARDS
NEED LETTER FROM HOA AND SCHOOL FEE
READY TO'ISSUE
LUISURIBE
11/17/2015
$62.36
11/23/15
R11064
20927
COMPLETE
CONSTRUCTION. '
AZA
ADDITIONAL 500 SF
LETTER.
CHECKLIST'
_
.11/23/2015
INCOR
SEE HOA LETTER ATTACHED.
BOB EDWARDS
ADDITION, EA
101-0000-42600
0-
$17.40
$17.40
11/23/15 `
- R11064
20927
CHECK
CONSTRUCTION
AZA
ADDITIONAL 500 SF PCI
: .
NAME TYP.E4
NAME ADDRE581 CITY
STATE
ZIP
PH..NE FAX
EMAIL s
INCOR
APPLICANT-
BOB EDWARDS CONSTRUCTION
51-455 DESERT CLUB
' LA QUINTA
CA
92253
INCORPORATED
DRIVE'
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
11/23/15
CONTRACTOR
BOB EDWARDS CONSTRUCTION
51-455 ''DESERT CLUB .
LA QUINTA.
CA
.-92253
INCORPORATED
DRIVE '
INCOR
OWNER
LEONOUDAKIS STEPHA1
56634 RIVIERA ,
r—LA QUINTA
CA
92253
BOB EDWARDS
Printorl• Mnnrinv NnvPmhar 71 ?nl S T,)7•S:% PM ofd � DEttii�Y
BOB EDWARDS
ADDITION, EA
101-0000-42400
0
$62.36
$62.36
11/23/15
R11064
20927
CHECK.
CONSTRUCTION. '
AZA
ADDITIONAL 500 SF
_
INCOR
BOB EDWARDS
ADDITION, EA
101-0000-42600
0-
$17.40
$17.40
11/23/15 `
- R11064
20927
CHECK
CONSTRUCTION
AZA
ADDITIONAL 500 SF PCI
: .
INCOR
BOB EDWARDS
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
11/23/15
R11064
20927
CHECK
CONSTRUCTION
AZA
INCOR
BOB EDWARDS
ADDITION, FIRST 100 SF
101-0000-42600
0
$171:14.
$171.14
11/23/15•
R11064
20927
CHECK
CONSTRUCTION
AZA
PC
INCOR
Total Paid for ADDITION: $371.73 $371.73,
BOB EDWARDS
HOURLY PLAN CHECK -
101-0000-42600
-1.25
$87.50 _
$87.50-
11/23/15
R11064
20927,
CHECK
CONSTRUCTION
AZA
YES
INCOR
Total Paid for BLDG CITY STAFF - PER HOUR: $87.50 $87:50'
Printorl• Mnnrinv NnvPmhar 71 ?nl S T,)7•S:% PM ofd � DEttii�Y
DESCRIPTION
ACCOUNT'
CITY
" a AMOUNT
PAID"
PAID
=,RECE!.P-f#1"'CHECK
#"
METHOD
PAID BYz
CLgY
BOB EDWARDS
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
11/23/15
R11064
20927 ,.,
CHECK
CONSTRUCTION
AZA"
INCOR
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $1.00
BSA:
BOB EDWARDS
RESIDENTIAL,.FIRST
101-0000-42403
0
$145.03
$145.03
11/23/15
R11064
20927
CHECK
CONSTRUCTION
AZA
1,0005E
INCOR.
BOB EDWARDS
RESIDENTIAL, FIRST
101-0000-42600
0
-$47.86
$47.86
11/23/15
1111064
20927
CHECK
CONSTRUCTION
AZA
1;OOOSF, PC
INCOR
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
BOB, EDWARDS
APPLIANCE
101-0000-42402
0 '.
$11.09:
$12.09.
11/23/15
R11064
-20927.
CHECK
CONSTRUCTION
AZA
REPAIR/ALTERATION
INCOR
BOB EDWARDS
APPLIANCE
101-0000-42600
0
$4.83
$4.83
11/23/15
R11064
20927
CHECK
CONSTRUCTION
AZA
REPAIR/ALTERATION PC
INCOR
Total Paid#or MECHANICAL: $16.92" $16:92. - - - -
_
BOB EDWARDS
ROOF DRAIN
101-0000-42401
0
$12.09
$12.09"
11/23/15
R11064
20927
CHECK
CONSTRUCTION
AZA
INCOR
BOB'EDWARDS
ROOF DRAIN PC
101-0000-42600
0
$12.09
$12.09
11/23/15
R11064
20927
CHECK
CONSTRUCTION
AZA
•
INCOR
Total,Paid for PLUMBING FEES: $24.18 $24.18
Printarl• Mnnrlav Nnvomhar 7q '7(11 S 7.77•S:t PM 2 of d
iST REVIEW - NEW CITY
DOC'" 11/10/2015... KATHRYN SAMUELS -STRUCTURAL TRANSMITTAL BRES 0
TRANSMITTAL 2015=0418 (lst).pdf
BRES2015'-0418-
_DOC 11/17/2015 LUIS-URIBE .SCHOOL -FEE LETTER 'r 0
SCHOOL FEE LETTER.pdf
'STATUS,
STAT
�...... .. ,:.._
:._
REVIEWTYPE. �...:.
�
..q:x:...
REVIEWER, SENT DATEDUE,DATET.:��
'::
.__ . _.RETURNED
K
�s 44 sr a.
NOTES
$.. :
�''
.
va... � .... ,..:. vv. .. ✓�'�
..a.�b°�..;�.
� .+ w. -. .. r k. _: 'ys.a ,. .... ✓.
..4..=Mz.nd..Cf,.A`....._..x. 5m-sC'_.'.uf ,..,.. .. ,.a..---.
... f 4.. .'�. �' ..
..._._i....r.....-.e....i ...v,v4. .+_.�l".... :#.
�J t: � �i ..r� e. i��" 'E' .4 wa
..x.. Y.a. �'.>., .. 3s .: .�£Y�i'Le.. ....}a.:,.. <v,;.._,_ .'; �a~i,:.v. �.:_f,e�c.~�'s.. .a{:i .z[•.
v<.a...b..-.....n:......i. ..,-.>
'11/16/2015.
APPROVED
IST BLDG NS-(2 WK),
' LUISURIBE`
;-11/17/2015
_10/30/2015
CONDITIONS .
1ST BLDG STR (2"-
YOUNG 10/30/2015
11/16/2015: ,11%10/2015•
READY FOR APPROVAL.i
,ENGINEERING .....
iST REVIEW - NEW CITY
DOC'" 11/10/2015... KATHRYN SAMUELS -STRUCTURAL TRANSMITTAL BRES 0
TRANSMITTAL 2015=0418 (lst).pdf
BRES2015'-0418-
_DOC 11/17/2015 LUIS-URIBE .SCHOOL -FEE LETTER 'r 0
SCHOOL FEE LETTER.pdf
BRES ozols- 10415
Bin #
City of La Quinta
Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
D La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: 56-634 Riviera
owner's Name: Stephan Leonoudakis
A.P.Number: -.762-023-004
Address: 56-634 Riviera
Legal Description:
City, ST, Zip: La Quinta, CA 92253
Contractor. Bob Edwards Construction
.';rcI0phpqq, (
�M, mom �
Address: 51-455 Desert Club Drive
Project Description:
City, ST, Zip: La Quinta, CA 92236
Proposed Atrium Enclosure (1 15-sg.ft)
Telephone: 760-771-4202
. el
. . . . . . .
Proposed 8864 skylight
City Lic. #,-.
Arch.,.Engr.,Designer:.. Gabriel Rios
Address: 49.901 Cinnabar Ln.
City., ST, Zip:. Coachella, CA 92236
Telephone: 760-485=7431
Construction Type: V-13 Occupancy: R-3
State Lic.
Project type (circle one): New (Addn) Alter Repair Demo
Nerve of Contact Person: Gabriel Rios
Sq. Ft.: 115 s.f.
# stories: 1
# Units:
kof Contact Person: 760-485-7431
Estimated Value ofPi..-oiqct:_.. $15,000.00
-Telephone
APPLICANT: DO NOT WRITE BELOW THIS. LINE..
N
Submittal
Reqld
Recld
TRACKING PERMIT -FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cales.
Called Contact Person
J
Plan Check Balance.
Title 24 Calts.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
21' Review, ready for corrections/issue
Electrical
Subcon tactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
H.O.A. Approval
Plans resubmitted
rading
IN HOUSE:-
1rd Review, ready for correctionstissue
q&Tpa Apact Fee
Planning Approval
Called Contact Person
A
Pub. Wks. Appr
Date of permit issue
School Fees
rI
otal Pcrmit Fees
TotalPcr
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/MD. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: PGA West
Owner's Name: Stephan Leonoudakis
Project Address: 56-634 Riviera, LaQuinta
Project Description: Atrium Enclosure
APN: 762-023-004 Tract #:
Type of Development: Residential XX! Commercial
Total Square Feet of Building Area: 115
Date: November 19, 2015
Phone No. 760-777-8202
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing c9*iie; that the abov formation is correct and makes this statement under
penalty of perjury and further represents that he/she is aut oriz d si 'n b al of the owner/ veloper.
Dated: November 19, 2015 Signature.
***********************************************************************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
115
$0.00
$0.00
Gov. Code Project Agreement Existing Not Subject to Fee
65995 Approval Prior to 1/1/87 Requirement
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Note:
Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
jurisdiction are, exempt from developer fees.
Certificate issued by: Laurie Howard, Secretary Signature: KIAf E4 -
NOTICE
' -
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. ,As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/mydocs/devfees/certificate of compliance fonn updated 3-2007 11/2010
November 19;,2015
Steoha6 C.'Leonoudakis
1 Valley Oaks 'Place
Santa Rbsa, 'CA 95409-6235
R&erence: 56-634 Riviera, La Quinta, CA 92253
Architectural Change Request = Atrium Skylights of a Legends.Unit
Deai_Stephan C. Leonoudakis,
The Architectural Committee had met on November 12,; 2015 and reviewed your application and
plans for an Atrium Enclosure with two skylights, subjecf to the following conditions, being met.
The Committee approved this application with the normal contingendes,andiCoveriant &
Maintenance . Agreement 'that the home6wner will, be responsible for any and all
downspout and" drainage off the roof' due, to .the change -in water, iflow. . All
recommendations-th6t,wefe.riiade by Paul Varini With AWS 'are to be followed 'exactly,
second exterior drain not necessary as long t as the homeowner, puts a sump pump and
backflow drain vaivi at the street'.-'
A Covenant and Maintenance Agreement will be required, one Will be•sent to.you for
proper exec 1 ution as soon asit.is prepared by counsel.
Your,, Contractor must meet with Mr. Pantanella, -Director of Community Services prior to
-:afiy,work commencing on this pr9ject, Mr. Pantanells's phone number is 7.60-564-',1032.
'iAll other PGAWEST II'Residential :Associ6ti6nArchitectural Rules &Regulatio
ns dated
5j20/2013*pertain.to,this project.
;Please contact Luis- Umanai -Sunshine Landscape at 760-346-3999 ,and Joanne Rose,
association Manager at 760-3 4-6-1161 ext.,- 1-47pri ioif to any irrigation modifications. if
-associated withAhis change. Damage to.the landscaping, i.e. shrubs' i trees, flowers and
(turf is7responsibilitythresponsibilityof the-contractor. The original landscaping must-be brought
aback to'its original condition!when the project is completed.
Approvals:given by the Architectural Committee are good for only six months from the'date on
1approvac lett&. -If construction has not commenced within six months after the project approval
datei a new,application must be submitted.
Upon cohripletidn of your project, ,please completed and return the Notice of Completion of
Archlt6d'ufal Change 6166g With City. of La'Q6inta Permits singed off by the City as approved
,final.
.. a VL
Padi II PGA` WEST Architectural Committee Meeting ; ,
' 'November 12;2015 Leonoudakis ,
'For additional information or questions, -the Board has directed thatyou'contact Joanne Rose;
CCAM; Association Manager, or Cathy Clark,,Assistant,Mina" ger; at 760/346 1161 ext '14T:or 123.
.. f., ... _ _.. . _ T ;
• respectively.
Sincerely,
PGA`WEST.II.Resident61 Association
Joanne,Rose CCAM Association Manager for`
Architectural Committee
Cc: Peters & Freedman.
f
r,
1 ,
BUILDING ENERGY ANALYSIS REPORT
CITY OF LA. QUINTA
BUILDING & SAFETY DEPT,
APPROVED
FOR CONSTRUCTION
ATE 11/17/15 RV -"�
/ r `
Q i
t'` C
PROJECT: .
Leonoudakis Residence
56-634 Riviera
La Quinta, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
I nsu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
Job Number:
Date:
10/20/2015
JOS
00� 3
CN of 0��� MENS
CbMM�N`�
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ener Pro 6.7 by Ener Soft User Number: 2655 ID:
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
EnergyPro 6.7 by EnergySoft Job Number: ID: User Number. 2655
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached . Calculation Date/Time: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 1 of 9
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Single Fam Detached
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 56-634 Riviera
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftz) 3146
15
Number of Zones 2
16
Slab Area (ft2) 3146
17
Number of Stories 1
18
Addition Cond. Floor Area 115
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 115
21
Glazing Percentage (%) 13.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-20 18:11:52
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
14.53
14.48
0.05
0.3%
Space Cooling
301.85
301.88
-0.03
0.0%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
8.16
8.16
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
324.54
324.52
0.02
0.0%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-20 18:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R -PRF -01
Project Name: Single Fam Detached Calculation Daterrime: 18:10, Tue, Oct 20, 2015 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: Leonoukakis Exist Addition.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cathedral Ceiling
• Window overhangs and/or fins
I HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• — None —
Cooling System Verifications:
• — None --
HVAC Distribution System Verifications:
• — None --
Domestic Hot Water System Verifications:
— None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)' 365.79 365.77, 0.02 0.0%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
'07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Fam Detached
3146
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Living
Conditioned
Living Zonet
3031
9
DHW Sys 1
Addition
Conditioned
Living Zone1
115
9
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-2018:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
06
07
08
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (112)
Window & Door
Area (11:2)
Tilt
(deg)
Status
Verified
Existing
Condition
Front Wall
Existing Living
Default.Wall 1978 to 1991
180
Front
3006
16
90
Existing
No
Left Wall
Existing Living
Default Wall 1978 to 1991
270
Left
1800
202.777
90
Existing
No
Rear Wall
Existing Living
Default Wall 1978 to 1991
0
Back
3000
176.262
90
Existing
No
Right Wall
Existing Living
Default Wall 1978 to 1991
90
Right
1800
90
Existing
No
Roof 2
Existing Living
Default Roof 1978 to Pres
3031
Existing
No
Front Wall 2
Addition
R-13 Wall'!
180
Front
390
90
New
N/A
Left Wall 2
Addition
R-13 Wallt
270
Left
1
90
New
N/A
Rear Wall 2
Addition
R-13 Wall1
0
Back
380
90
New
N/A
Right Wall 2
Addition
R-13 Wall'!
90
Right
1
90 '
New
N/A
OPAQUE SURFACES— Cathedral Ceilings
01
02
03
04
05
06
06
07
08
09
10
11
12
13
Name
Zone
Type
Orientatio
n
Area
(ft)
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof
Tilt(deg)
Roof
Reflectan
ce
_
Roof
Emittance
Framin
g
Factor
Status
Verified
Existing
Condifion
Roof
Addition
R-19 Roof
Front
115
18.7
0
0
0
0.7
0.7
0.1
New
N/A
ATTIC
01
02
03
04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Attic Existing Living
Attic RoofExisting Living
Ventilated
0
0.1
0.85
No
No
Exi ti
No
ng
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-10-20 18:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Front Wall (Front -180)
8.0
1.0
1
8.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 2
Front Wall (Front -180)
8.0
1.0
1
8.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 3
Left Wall (Left -270)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 4
Left Wall (Left -270)
6.0
6.8
0.98
40.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 5
Left Wall (Left -270)
2.0
4.0
3
24.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 6
Left Wall (Left -270)
1.0
6.0
1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 7
Left Wall (Left -270)
5.0
6.8
0.982
33.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 8
Left Wall (Left -270)
1.0
6.0
1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 9
Left Wall (Left -270)
6.0
6.8
0.98
40.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 10
Rear Wall (Back -0)
2.0
4.0
1
8.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 11
Rear Wall (Back -0)
2.0
4.0
1
8.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 12
Rear Wall (Back -0)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 13
Rear Wall (Back -0)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 14
Rear Wall (Back -0)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Skylight
Roof (Front -180)
----
----
1
18.7
0.36
0.24
None
New,
N/A
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-10-2018:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
4
0
0.1
0
4
0 0.1
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2
0
0
0
0
0
•0
0 0
0
Window 9
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 10
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 11
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 12
2
0.1
2
2
0
4
0
0.1
0
4
0 0.1
0
Window 13
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 14
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-20 18:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation DatelTime: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
1
None
0.8
No
Existing
No
• Cavity/ Frame: no insul. /2x4 Top Chrd
Addition
115
1
2x4 Top Chord of Roof Truss @ 24
0.8
No
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting Living
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle) .
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
• Exterior Finish: Wood
Default Wall 1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 ® 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
• Over Floor Joists: R-9.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/ Frame: R -19/2x8
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R5 Sheathing
R-19 Roof
Cathedral Ceilings
Wood Framed Ceiling
2x8 ® 16 in. O.C.
R 19
0.042
• Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
Existing Living
3031
1
None
0.8
No
Existing
No
Slab -on -Grade
Addition
115
1
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-10-20 18:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.6 EF
43000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Living Zonal
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3146
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-20 18:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Daterrime: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 8 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Verified Duct Location
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
8.0
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-2018:11:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Daterrime: 18:10, Tue, Oct 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Leonoukakis Exist Addition.xml
CF1 R -PRF -01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Si nature:
Joan D. Hacker
D
Company:
Signature Date:
Insu-form, Inc.
10/20/2015
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/StatePalm Desert, Ca 92211
Phone: 760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
1 certify the following under penalty of perjury, under the laws of the State of California:
1. l am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the ' mation provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building p mit alIpplication
Responsible Designer Name:
Responsible Designer S' nature
Gabriel Rios
Company:
Date Signed:
RiosDesigns
10 6/ 15
Address:
License:
49-901 Cinnabar lane
N/A
City/State/Zip:
Phone:
Coachella, CA 92236
(760) 485-7431
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-20 18:11:52
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Leonoudakis Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
10/20/2015
Project Address
56-634 Riviera La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,146
Addition
115
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Slab Unheated Slab -on -Grade
- no insulation 3,031 Perim = 1Existing
Wall Wood Framed
R11 9,205 Existing
Roof Wood Framed Attic
R 19 3,031 Existing
Demising Wood Framed
R 13 1 Existing
Wall Wood Framed
R 13 772 New
Roof Wood Framed Rafter
R 19 96 Rigid=R-5.0 Cool Roof New
Slab Unheated Slab -on -Grade
- no insulation 115 Perim = 1' New
FENESTRATION
Orientation Area(ft)
I Total Area: 414 Glazing Percentage: 13.2 % New/Altered Average U -Factor: 0.36
U -Fac SHGC Overhang Side -fins Exterior Shades Status
Front (S) 8.0
0.710
0.73 2.0 4.00/4.00 Bug Screen Existing
Front (S) 8.0
0.710
a 73 2.0 none Bug Screen Existing
Left (149 202.8
0.710
0.73 2.0 none Bug Screen Existing
Rear (N) 122.8
0.710
0.73 2.0 none Bug Screen Existing
Rear (N) 53.4
0.710
0.73 2.0 4.00/4.00 Bug Screen Existing
Skylight 18.7
0.360
0.24 none none None New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace
78% AFUE
Split Air Conditioner 12.0 SEER Setback Existing
HVAC DISTRIBUTION
Location Heating'
Duct
Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic 8.0 Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
Ener Pro 6.7 by Ener Soft User Number: 2655
RunCode: 2015-10-20T18:12:41 /D: Pae 12 of 17
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance aDDroach used. Exceptions may aDDly. Review the resDective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-11l(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110 8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of cool roof is specified on the CFIR.
§ 110.86):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)]:
walls, vented attics and unvented attics with air -permeable insulation.
§150.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)1 A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§I50.0(e)lB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and fight -fitting damper or a combustion -air control device.
§ 150.0(e)] C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§I 10.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in § 150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)] A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.06)] B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I50.06)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Cl ass I
§ I50.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)] 5:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(0)1 A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ I I0.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
ed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0 2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, 130.0, § 130.2, § 130.4, 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §1 50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9 § 130.0 § 130.2 130.4 140.7 and 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9 130.0 § 130.2 § 130.4 § 140.7 and 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 130.0 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§1 10.10(a)]:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10 e .
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§1 10.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered panting installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Leonoudakis Residence
Date
10/20/2015
System Name
Living Zone
Floor Area
3,146
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 3,289
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 36,000
74,126
2,945 5,617
73,207
Total Output Btuh 36,000
0
Output Btuhls 11.4
4,279
3,598
Cooling System
0
0
Output per System 36,000
0
0 0
0
Total Output Btuh 36,000
0
2,945
0
Total Output Tons 3.0
4,279
3,598
Total Output Btuh/s 11.4
Total Output s on 1,048.7
82,684
80,403
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow dm
2,210
Existing 20,415
14,314
36,000
Airflow dmfs
0.70
Total Adjusted System Output 20,415
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
14,314 36,000
Aug 3 PM Jan 1 AM
Airflow dmfTon 736.7
Outside Air % 0.0%
Outside Air dm/s 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
68 OF
68 OF 84 °F 84 OF
n
LEI E�
Heating Coil Supply Fan
2,210 cfm
82 OF
r-
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112178 OF
Outside Air Ar
0 cfm
80170 OF
80 ! 70 OF 55 / 62 OF 55 / 62 OF
60
Cooling Coil Supply Fan 57 ! 62 OF
2,210 cfm - 65.4% ROOM
78169 OF
EnergyPro 6.7 by EnergySoft
User Number: 2655 RunCode: 2015-10-20718:12:41 ID: