05-2066 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA .QUINTA, CALIFORNIA 92253
Application Number:
L _05-00002066
Property Address:
79860 RIVIERA
APN:
762 -070 -002 -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
90169
Tityl'4 4v Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Applicant: Q rchitect or Engineer:
AUG 01 20 c. No.: ---------------
I hereby
Owner:
DUNCAN, CLAY -
79860 RIVIERA
LA' QUINTA, CA 92253
Contractor:
EDWARDS CONSTRUCTION, BOB
51455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
(760)777-8202
Lic. No.: 684857
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153-
Date:
77-7153
El—Ty-0 F LA (lues 1••
FINANCE �FPT�__�
—_'------------------------------------------------------------- ------
LICENSED CONTRACTOR'S DECLARATION
under penalty of per ury at I a lice nd provisions of Chapter 9 (commencing with
of Division 3 of the Busi ss 7 dd , es ' a de, and my Li nse is in full force and effect.
B / / "AEe No.: 6857
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ I I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.). '
Lender's Name:
Lender's Address:
LQPERNHT
Date: 7/29/05
WORKER'S COMPENSATION DECLARATION.
hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier VIRGINIA SURETY Policy Number 00500027012
I ertify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any man r o as to become su ' ct to the workers' compensa ' n laws of California,
and agree that, if uld b esu workers' compensatio rovisions of Section
9
3700 of th�e.Cabo de, I o.,dJ t c mply With those ProvisiopS /
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. .
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuaJ
h permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state above inf ation is c rrec . I agree to comply with all
city an /cou yordinancesand state laws rela tructi nd ere y authorize represent tivof this un to enter upon eabove-mention n tion purpo es
�e? gnature (Applicant or Ag
r
Pr
Application Number . . . . 05-00002066
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . .
599.00
Plan Check Fee
389.35
Issue Date . . .
Valuation . . . .
90169
Expiration Date—
1/25/06
Qty Unit Charge
Per
Extension
BASE
FEE
414.50
41:00 4.5000
----------------------------------------------=-----------------------------
THOU BLDG
50,001-100,000
184.50
Permit . . .
ELECT - ADD/ALT/REM
Additional desc .
.Permit Fee . . .
61.66..
Plan Check Fee
15.42
issue Date
Valuation . . .
0
Expiration Date
1/25/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1113.00 .0350
ELEC
NEW RES - 1 OR 2 FAMILY
38.96
385.00 .0200
----------------------------------------------------------------------------
ELEC
GARAGE OR NON-RESIDENTIAL
7.70
Permit . . .
GRADING PERMIT
Additional desc .
Permit Fee . . . .
15.00
Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date
1/25/06
Qty Unit Charge
Per
Extension
---------------------------=------------------------------------------------
BASE
FEE
15.00
Permit . . .
MECHANICAL
Additional desc .
Permit Fee . . . .
59.00
Plan Check Fee
14.75
Issue Date
Valuation . .
0
Expiration Date
1/25/'06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00 9.0000
EA MECH
FURNACE <=100K
9.00
1.00 9.0000
EA MECH
B/C <=3HP/100K BTU
9.00
4.00 6.5000
----------------------------------------------------------------------------
EA MECH
VENT FAN
26.00
Permit . . . . . .
PLUMBING
LQPERMIT
Application Number . . . . . 05-00002066
Permit PLUMBING _
Additional desc .
Permit Fee . . . . 93.00 Plan Check Fee
23.25
Issue Date . . . . Valuation . . .
. 0
Expiration Date 1/25/06
Qty Unit Charge Per
Extension.
BASE FEE
15.00
11.00 6.0000 EA PLB FIXTURE
66.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
3.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
9.00
----------------------------------------------------------------------------
Special Notes and Comments
rem/ add 1414 sq. ft.June 7, 2005
1:12:20 PM jjohnson
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE•
38.94
STRONG MOTION (SMI) - RES
7.29
Fee summary Charged' Paid Credited
Due
Permit Fee Total 827.66 .00 .00
827.66
Plan Check Total 442.77 .00 .0.0
442.77
Other Fee Total 46.23 .00 ..00
46.23
Grand Total 1316.66 .00 .00
1316.66
LQPERAIIT
1
Bin #
Permit # '2xr6 (b17
�j
k
t Address:.-Number:Description:ctor:
Address:
City, ST, Zip:
Telephone: '777
State Lic. # :
gr, Designer:
Address:
Citi•, ST, Zip: L
Telephone: Z
G
State Lic. #:
Name of Contact Person:
Telephone # of Contact Person
M
City of La Quinta
Building 8t Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012 M�M GL A y
Building Permit Application and Tracking Sheet 1�>UA,1V
Owner's Name: 0
'Address: `/19— C9GQ
�� rf City, ST, Zip::
Telephone: ( ��_:..:.:...........................
Project Description:
lel ( !�
Lic. #:
10'-5 a�- crc,-A- TLE) -OS
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal
Req'd Req'd TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
� Item
Structural Calcs.
Reviewed, ready for corrections
Amount
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Cafes.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
1
11Lechanical
Grading plan
2wd Review, read} for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
SAI.I.
II.O.A. Approval
Plans resubmitted
Grading
IN IIOUSE:-
7r° Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I. .P.
Pub. 11'ks. Appr
Date of permit issue
6
School Fees
71ta�65 Vls
l"otalPerit Pee
ms
000U�lbIt.,
10'-5 a�- crc,-A- TLE) -OS
Date
7/29/05
No.
27465
Owner
Duncan
Address
79860 riveiera
City
La Quinta Zip 92253
Tract #
Type
Residential Addition
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
Jurisdiction
Permit #
Study Area
No. of Units
zoo � o
BERMUDA DUNES r
Cr RANCHO MIRAGE
INDIAN WELLS
PALM DESERT y
LA QUINTA
O INDIO y�
762-070--2
La Quinta
i
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 79860 Riviera 1414 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 1,414 S.F. or $3,167.36 have been paid for the property listed above and that
building. permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/1 st Bank - Bob Edwards Check No. 76663
Name on the check Telephone 777-8202
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by n MCGllvrey Payment Recd
$3,167.36! er/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permitfor this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting
��-31-Z005(NED) .01.53 P, OOZIOOZ
r TANDY'S INSPECTION SERVICES, INC.
PO. BOX 13766 - PALM DESERT, CA 92255.3766
'OFFICE / FAX - 951.759.9717
PAGER 760.776.3339
SPEGIAL. INSPECTION DAILY J WEEKLY REPORT
TYPE`INSPECTION PERFORMED
eO.�f
PERMIT NUM13ER
"6'��a
TYPE OFSTRUCTURE
'PROJECTADORESS4N STRELTADDR�ANDCflTDR'CDUN"
a400 AX,\Meiz-A,- -�`-+
PROJECT N9NE wTauDceouRDRf 6118 BUY41EBS PJV�YCC�OM76 W7193 ECT. P4NFI
Rk&, Mf S-. C-t.A 4 .1�u rJCA4
ECT
GCO-T 4 • _Pri,GW n1)
ENGINEER
IZ A. \K r -r PA r-4AtrA144 rJA M
GENERAL CONTRACTOR
Sc 'DwAgg5, 16fJry ' t�7
SUBCONTRACTOR
DESCRIPTION OF WORK INSPECTED
- fF 106 I n a'j
,=mezcz SPT �0
ski Ag 4 z jj'A
Af If cx,,, .3
- g
• • Irl } i �� � „r
WELDING INFORMATION
WEL.DIZRS NAME CED TIFYINGAGENCY NAME AND NUMBER PROCESS AND ELECTRODE
SAMPLE INFORMATION
TIME SUPPLIER T1CKETNUMBER MIX NUMBER AIRTEMP SAMPLE SLUMP WATER 11MEIN
TEMP AODED MIXER
LOCATION TAKEN:
LOCATION TAKEN:
I HEIIeCY CERTII!iZMAT 1 HAve,INSPEM0 ALL Of nig ABOVE REPORTED WORK VNu68
OTHVA NSE HOTM AND Tv 7He DEBT OF IWA&RTrY i Owe FOUND YNIS WORK TO COMPLY VATH
."APPROVED RUI7B, IFlGriOPffi LAPPLQ', D 01111.111111 LAW&
�,-INSPECTORS SIGNATURE
nice t 0 4 q 3a /
INSPECTORS CERTIFICATION AGENCY AND NUMBER
TITLE 24 REPORT
Title 24 Report for:
Mr. & Mrs. Clay Duncan -Addition
79-860 Riviera
La Quinta, Ca 92253
Project Designer:
Robert A. Pitchford, Design & Drafting
41-625 Eclectic St., #A-2
Palm Desert, Ca 92260
(760) 346-2856
Report Prepared By:
Tim Scott
H & H Air Conditioning
74-991 Joni Drive #20
Palm Desert, CA 92260-2043
(760) 340-3088
Job Number:
CITY OF LA QUINTA
BUILDING & SAFETY DEPT
APPROVED
FOR CONSTRUCTION
DA 2 5
' D �C�L�OC�L�
Date:
' JUL 15 2005
7/1 /05
By
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This prog a as -apo
i authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1R Mandatory Measures Checklist
Form C -2R Computer Method Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
6
8
15
16
17
18
EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
•Mr. & Mrs. Clay Duncan -Addition 7/1/05
Project Title Date
•
•
79-860 Riviera La Quinta
vro/ect Aaaress
H & H Air Conditioning (760) 340-3088
Documentation Author a ep one
Computer Performance 15
Compliance Method (Package or Computer) Climate Zone
GENERAL INFORMATION
Total Conditioned Floor Area:
Total Conditioned Slab Area:
Building Type:
(check one or more)
® Single Family Detached
❑ Single Family Attached
❑ Multi -Family
Building ermi
Plan Check Date
Field ec Date
enrorcemem: Agency use uniy
1,414 ft2 Average Ceiling Height:
1,414 ft2
® Addition
❑ Existing Building
❑ Existing Plus Addition
Front Orientation: (South) 200 deg Floor Construction Type: X❑ Slab Floor
Number of Dwelling Units: 0.30
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
10.0 ft
Component
Type
Frame
Type
Assembly
U -Value
Location/Comments
(attic, garage, typical, etc.)
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof
R-19 Wall (W.19.2x6.16)
Wood
0.065
Exterior Wall
Slab On Grade
n/a
0.756
Covered Slab MR -0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Exposed Slab MR -0.0 Perimeter Insulation
FENESTRATION
Shadinq Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
(SF)
U -Factor
SHGC
Shading
Yes / No
Yes / No
Skylight
12.0
0.80
0.39
None
❑X❑
❑ ❑X
Rear
(North)
74.6
0.72
0.60
Bug Screen
❑
X❑
❑ ❑X
Rear
(North)
128.0
0.85
0.59
Bug Screen
❑X❑
❑X❑
Right
(East)
21.0
0.72
0.60
Bug Screen
1:1
0
El XRight
(East)
45.0
0.85
0.59
Bug Screen
1-1
El
1:1 XFront
(South)
22.0
0.87
0.59
Bug Screen
❑
X❑
1:1 XFront
(South)
27.5
0.72
0.60
Bug Screen
❑
X❑
❑ ❑X
Left
(West)
24.0
0.85
0.59
Bug Screen
❑
X❑
❑ ❑X
Left
(West)
45.0
0.87
0.59
Bug Screen
❑
n
❑ X❑
Left
(West)
63.8
0.72
0.60
Bug Screen
❑
0
❑ X❑
❑
❑
❑ ❑
❑
❑
❑ ❑
Run Initiation Time: 07/01/05 13:12:46
Run Code: 1120248766
EnergyPro 3.1 By EnergySoft
User Number: 5533
Job Number:
Page:3 of 19
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: Robert A. Pitchford, Design & Drafting
Address: 41-625 Eclectic St., #A-2
PajwrDeWrt, C 92260
Telephone 60) 346-
Lic. #:
o. -
(s' a (date)
E forcement ency
Name:
Title/Firm:
Address:
Telephone:
Name: Tim Scott
Title/Firm: H & H Air Conditioning
Address: 74-991 Joni Drive #20
Palm Desert, CA 92260-2043
Telephone: (760 340-3088
ifOS
(signature) I ( ate)
signature/stamp) date
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: PageA of 19
Certificate of Compliance: Residential
(Part 2 of 2)
CF -1 R
Mr. & Mrs. Clay Duncan -Addition
7/1/05
Project Title
Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping
Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value
Type Comments
Central Furnace 80% AFUE Ducts in Attic 4.2
Setback HVAC -1
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct
Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value
Type Comments
Split Air Conditioner 13.0 SEER Ducts in Attic 4.2
Setback HVAC -1
WATER HEATING SYSTEMS
Rated 1
Tank Energy Facts 1
External
Water Heater Water Heater Distribution # in Input
Cap. or Recovery Standby
Tank Insul.
System Name Type Type Syst. Btu/hr
(gal) Efficiency Loss (%)
R -Value
i
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: Robert A. Pitchford, Design & Drafting
Address: 41-625 Eclectic St., #A-2
PajwrDeWrt, C 92260
Telephone 60) 346-
Lic. #:
o. -
(s' a (date)
E forcement ency
Name:
Title/Firm:
Address:
Telephone:
Name: Tim Scott
Title/Firm: H & H Air Conditioning
Address: 74-991 Joni Drive #20
Palm Desert, CA 92260-2043
Telephone: (760 340-3088
ifOS
(signature) I ( ate)
signature/stamp) date
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: PageA of 19
Certificate of Compliance: Residential (Addendum) CF -1 R
�r. & Mrs. Clay Duncan -Addition 7/1/05
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
4
F'1__
L.
JOACU VII 1110 OUcy UOVy VI IIIC APC4,141 JUDUIIGOUVII CMU UUGUII1tl1114LIVI1 DUUIIIIIICU.
The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
.......:.I..r Y6 ueoc _.............• .1.._......_-.. 41._ s:. IA ...._u: _...:-- ---I -1: ------ :_ .__a:.-_. _L.6--- u---••--- -- -
M1 OV -1. I I— 11— 1OIGI IIIUJI UVl.UI11CI11 1110 1101U ver,,I .OIIVII OIIU UIay1lVJlll, ICJUIIU VI IIIVDV IIICasuies VII a IVI I,, C.r-611.
an
e
e HVAG SyStem - me u es Ketrigerant Charge and Airflow Credit (ora certified HF_K5 rater must providi
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
Run Initiation Time: un Code: 1120248766 1
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 19
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
• asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
is
C J
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
®*§150(a): Minimum R-19 ceiling insulation.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value.
'§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
® not apply to exterior mass walls).
❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
§150(l): Slab edge insulation -water absorption rate no greater than 0.5%, water vapor transmission rate no
E] greater than 2.0 perm/inch.
® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joists and penetrations caulked and sealed.
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
F] §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
Installation Fireplaces, Decorative Gas Appliances Gas Logs.
§150(e): of and
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
® § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
® §150(i): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating,sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 19
is
•
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk
(') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are
shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMI
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
[(1 '§ 150(m): Ducts and Fans
uu
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL161A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
n§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§ 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
L� §118 (f): Cool Roof material meet specified criteria
Lighting Measures
`
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
u §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
.NT
I
I
3.1 By EnergySoft User Number: 5533 Job Number: Page:7 of 19
Computer Method Summary (Part 1 of 3) C -2R
r. & Mrs. Clay Duncan -Addition
--- —
X❑ Slab Floor
--
7/1/05
-Date
ojeci Title
Single Fam Detached
Building Front Orientation:
(South) 200 deg Total Fenestration Area: 32.7%
79-860 Riviera La .Quinta
0.30 Total Conditioned Volume: 14,140
Number of Stories:
1 Slab Floor Area: 1,414
BUILDING ZONE INFORMATION
Project Address
Zone Name
Floor Area Volume Units Zone Type Type Hgt. Area
HVAC -1
Building Permit # -
H & H Air Conditioning
(760) 340 -3088
-Documents if on Au of r
Gains
Telep on—�
Tilt Y / N Form 3 Reference Location / Comments
Plan Check/Date
Computer Performance
Wall 77 0.065 20
15
Wall 494 0.065 110
FIeIdClteck/Date --
Compliance Method -(Package or ComputerClimate
90 [ ❑ R-19 Wall (W.19.2x6.16) Addition -__• ...- -_ .
Zone
----- -
Source Energy Use Standard
Proposed
Compliance
---
(kBtu/sf-yr) Design
Design
Margin
Existing+Addition Budget Adjustment
Space Heating 4.44
7.52
-3.08
Ratio F: 2379 / 1414 = 1.682
Space Cooling 38.25
65.31
-27.06
Budget Adj: 1.682 X ( 77.14 - 46.55) = 51.47
Domestic Hot Water
0.00
0.00
The budget shown to the left has been increased using
X0.000
Totals 51.47+ �L.V- - 94.16
72.83
-0,3�
this Budget Adjustment based upon Existing building
information shown on the C -2R which follows this form.
ULNLKAL INI-UKMA I IUN
X❑ Slab Floor
Conditioned Floor Area:
1,414 Floor Construction Type: ❑ Raised Floor
Building Type:
Single Fam Detached
Building Front Orientation:
(South) 200 deg Total Fenestration Area: 32.7%
Number of Dwelling Units:
0.30 Total Conditioned Volume: 14,140
Number of Stories:
1 Slab Floor Area: 1,414
BUILDING ZONE INFORMATION
# of Thermostat Vent
Zone Name
Floor Area Volume Units Zone Type Type Hgt. Area
HVAC -1
1,414 14,140 0.30 Conditioned _ Setback _- 2 n/a
OPAQUE SURFACES Act.
Gains
Type Area U -Fac. Azm.
Tilt Y / N Form 3 Reference Location / Comments
Roof _ 1,402 0.028 0
20 [,� ❑ R-38 Roof (R.38.2x14.16) Addition
Wall 77 0.065 20
90 ❑ R-19 Wall (LN.19.2x6.16) Addition
Wall 494 0.065 110
90 [ ❑ R-19 Wall (W.19.2x6.16) Addition
Wall 370 0.065 200
90 [ ❑ R-19 Wall (W.19.2x6.16) Addition -__• ...- -_ .
Wall 247 0.065 290
90 ❑ R-19 Wall (LN.19.2x6.16) Addition -_ •. ____
_-_
- ---
❑ ❑
---
- - - -
❑ ❑ - --- - --
- --- -
❑ ❑
- --- -
❑ ❑
°a °❑
--- —
❑ ❑
-- - ------ — --
❑ ❑ - --
°❑ F-1
-
--
o ❑❑
+--
--
o o
1:1 El
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
EnergyPro 3.1 By EnergySoft
User Number: 5533 Job Number: Page:B of 19
Computer Method Summary (Part 2 of 3) C -2R
A! . & Mrs. Clay Duncan -Addition 7/1/05
,111111111111roj Title -Date `---- "-
U- Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
1
Skylight Rear
North
12.0
0.800
0.39
0
20 Double Metal Tinted Default
Addition
2
Window Rear
(North)
10.8
0.720
0.60
20
90 Double Metal Tinted Default
_
Addition
3
Window Rear
(North)
48.0
0.850
0.59
20
90 Double Metal Tinted Default
_
Addition ~
4
Window Rear
(North)
52.5
0.720
0.60
20
90 Double Metal Tinted Default
Addition _ _
-__
5
Window Rear
(North)
80.0
0.850
0.59
20
90 Double Metal Tinted Default
Addition
6
Window Rear
(North)
11.2
0.720
0.60
20
90 Double Metal Tinted Default
Addition
7
Window Right
(East)
12.0
0.720
0.60
110
90 Double Metal Tinted Default
Addition
8
Window Right
(East)
45.0
0.850
0.59
110
90 Double Metal Tinted Default
Addition
9
Window Right
(East)
9.0
0.720
0.60
110
90 Double Metal Tinted Default
_
Addition
10
Window Front
(South)
22.0
0.870
0.59
200
90 Double Metal Tinted Default
_
Addition
11
Window Front
(South)
27.5
0.720
0.60
200
90 Double Metal Tinted Default
Addition -_ u
12
Window Left
(West)
24.0
0.850
0.59
290
90 Double Metal Tinted Default
Addition
_13
Window Left(West
15.0
0.870
0.59
290
90 Double Metal Tinted Default
Addition
14
Window Left
(West)
15.0
0.870
0.59
290
90 Double Metal Tinted Default
Addition
15
Window Left
(West)
15.0
0.870
0.59
290
90 Double Metal Tinted Default
Addition
16
Window Left
(West)
63.8
0.720
0.60
290,
90 Double Metal Tinted Default
Addition
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
_Hg�/Vd-
-Len. Hgt.
EExt RExt. -Dist.-Len.
Hg-.-DW.--_Len-'-_-Hgt'.
1 ---None
1.00---
2
Bug Screen
0.76
3
Bug Screen
0.76
--'- -- "
4
Bug Screen
0.76
5
Bug Screen
0.76
_
- -
6
Bug Screen
0.76
7
Bug Screen
0.76
-8-
Bug Screen
0 76
-"
9
Bug Screen
0.76
10
Bug Screen
0.76
-- - -
11
Bug Screen
07fi
-- -"
12
Bug Screen
0:76-
--- ---
13
Bug Screen
0-7fi
----
14
Bug Screen
15
Bug Screen
0:76
--
16
Bug Screen
0:76-
-- -
Or
_
Run Initiation Time: 07/01/05 13:12:46
Run Code: 1120248766
EnergyPro 3.1
By EnergySoft
User Number: 5533
Job Number:
_ Page: 9 of 19
Computer Method Summary (Part 3 of 3) C -2R
40 r. & Mrs. Clay Duncan -Addition 7/1/05
ojecfTitle— — -Date --. ` - _ '
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 128 0.76 0.0 0 Addition
Slab Perimeter 34 0.76 0.0 0 Addition
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1
Oydronic Piping
System Name
Pipe Pipe Insul.
I Pnnth ninmPtPr Thirk
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
Split Air Conditioner
Duct Thermostat
R -Value Type
4.2 Setback
Location /
Comments
HVAC -1
WATER HEATING SYSTEMS
Duct
Minimum
Efficiency
Location
(SEER)
(attic, etc,)
47 A CLCD
rlunk :n AH:n
Duct Thermostat
R -Value Type
4.2 Setback
Location /
Comments
HVAC -1
WATER HEATING SYSTEMS
Ratedl
Tank
Energy Fact!
Tank Insul.
Water Heater Water Heater Distribution
# in Input
Cap.
or Recovery
1
Standby R -Value
System Name Type I Type
Syst. (Btu/hr)
(gal)
Efficiency
Loss (%) Ext.
1 For small gas storage (rated Input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number:
Page: 10 of 19
Computer Method Summary (Addendum) C -2R
r. & Mrs. Clay Duncan -Addition
7/1/05
Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special.
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
r
JaDwu UPI LIM aUWLIUa Vy UI LIM ZDPW%,IaI JUDLl I .OL1U11 allu UUL U111Cl UaLIU11 pUUIIIILLWU.
The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
.--...:J.. TL. LJ LPJ G� ..�.�- �..�� J��..���• •L. L:�IJ ..�-: L:��a.�� ��J J:������.� a��a.�� �L �L��� ����..��� �� �
� rov1ue . I PIC HL-r%Q Pater IIPUSL docuPl enL LIC Held verlie La Llon and ulagnOSLIC testing VI Lhese measures VII a IVIIII L..r-O R.
an
Field
e HVAU,5ystem includes Refrigerant Charge and Airflow Credit (ora certmea HhKu rater must provicle
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
Run InitiationTime: un Code: 1120248766 1
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 19
Computer Method Summary
Act.
Azm.
0
20
110
200
200
200
290
—..__
-
Tilt
20
90
90
90
90
90
90
—
(Part 1 of 3) C -2R
Wr. & Mrs. Clay Duncan -Existing Res
Form 3 Reference
---
7/1/05
-Date
6jiffiTitle
Default Wall 1992 -Present
Solid Wood Door
Solid Wood Door
79-860 Riviera La Quinta
_---
-Project Ad -dress
Building Permit #--`-------
H & H Air Conditioning
(760) 340-3088
---'-
-Documentation Au of 1�r
Telephone
Plan Check/Date
Computer Performance
15
FW—d-Check/Date -- -
-Compliance INeth-o-a-(Pac ak ge or Computer
Timateons
--- -
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 4.70
7.46
-2.77
Space Cooling 41.85
69.68
-27.83
Domestic Hot Water 0.00
0.00
0.00
Totals 46.55—
77.14
-30.59
xis Ina
Esulliclina
Information
ItKAL INI-UKMA i IUN O Slab Floor
Conditioned Floor Area: 2,379 Floor Construction Type: ❑ Raised Floor
Building Type: Single Fam Detached
Building Front Orientation: (South) 200 deg Total Fenestration Area: 25.7%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 23,790
Number of Stories: 1 . Slab Floor Area: 2,379
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
HVAC -1 2,379 23,790 1.00 Conditioned Setback 2 - n/a
OPAQUE SURFACES
Type Area U -Fac.
Roof _ _ 2,379 0.047
Wall _ 289 0.088
Wall 837 0.088
Wall 490 0.088
Door 48 0.387
Door 24 0.387
Wall _ 859 0.088
- ----
— --- --
--
---- -----
---
WE
Act.
Azm.
0
20
110
200
200
200
290
—..__
-
Tilt
20
90
90
90
90
90
90
—
Solar
Gains
Y
[X
[1
[
[
[
[
❑
❑
❑
❑
❑
❑
/ N
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑\
❑
❑
❑
Form 3 Reference
Default Roof 1978 to Present
Default Wall 1992 -Present
Default Wall 1992 -Present
Default Wall 1992 -Present
Solid Wood Door
Solid Wood Door
Default Wall 1992 -Present
---
Location / Comments
Existing Res
Existing Res
Existing Res
Existing Res
Existing Res
Existing Res
Existing Res
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
_— Energy Pro 3.1 — By EnergySoft User Number: 5533 Job Number: — —
------ — Page: 12 of 19
Computer Method Summary (Part 2 of 3) C -2R
�r. & Mrs. Clay Duncan -Addition 7/1/0. 5
olect Title --
Ll- Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
1
2
3
�4
5
6
7
8
79 -
TO
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
r�
Window
Rear
North
Window
Rear
(North)
Window
Rear
(North)
Window
Rear
(North)
Window
Rear
(North)
Window
Rear
(North)
Window
Rear (North)
Window
Rear
(North)
Window
Right
(East)
Window
Right
(East)
Window
Right
(East)
Window
Right
(East)
Window
Right
East
Window
Right
(East)
Window
Right
(East)
Window
Right
(East)
Window
Right
(East)
Window
Right
(East)
51.1
64.0
21.9
43.8
21.9
48.0
12.0
48.0
34.3
10.0
10.0
15.9
6.0
15.9
6.0
15.9
6.0
15.9
6.6
37.8
15.0
15.0
8.0
16.0
32.9
34.3
0.720
0.850
0.720
6.720
0.720
0.850
0.720
0.850
0.720
0.870
0.870
0.720
0.870
0.720
0.870
0.720
0.870
0.720
0.720
0.870
0.870
0.870
0.870
0.720
0.720
0.720
0.73
0.70
0.73
0.73
0.73
0.70
0.60
0.59
0.73
0.70
0.70
0.73
0.70
0.73
0.70
0.73
0.70
0.60
0.60
0.59
0.70
0.70
0.59
0.60
0.60
0.60
20
90 Double Metal Clear Default
20
90 Double Metal Clear Default
20
90 Double Metal Clear Default
20
90 Double Metal Clear Default
20
90 Double Metal Clear Default
20
90 Double Metal Clear Default
20
20
90 Glass Block
90 Double Metal Tinted Default
110
90 Double Metal Clear Default
110
90 Double Metal Clear Default
110
90 Double Metal Clear Default
110
90 Double Metal Clear Default
110
90 Double Metal Clear Default
110
110
90 Double Metal Clear Default
90 Double Metal Clear Default
110
90 Double Metal Clear Default
110
90 Double Metal Clear Default
110
90 Double Metal Tinted Default
110
90 Glass Block
200
90 Double Metal Tinted Default
290
90 Double Metal Clear Default
290
90 Double Metal Clear Default
290
90 Double Metal Tinted Default
290
90 Glass Block
290
90 Double Metal Tinted Default
290
90 Double Metal Tinted Default
Existing Res
Existing Res _
Existing Res
Existing Res
Existing Res
Existing Res
Existing Res _
Existing Res
Existing Res
Existing Res
Existing Res
Existing Res
Existing Res _
Existing Res _
Existing Res
Existing Res
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGCgH
t. Wd-
-Len.
Hgt.L-Eit. -REit.
-Dist: Len. Hgi.
1-Bug
Screen
0.76
7-3-7:0
10-0
2
Bug Screen
0.76
8.0 8.0
10.4
0.1 10.0
10.0
3
Bug Screen
0.76
7.3 3.0
4.4
0.1 4.0
4.0
_
4
Bug Screen
_
0.76
-
5
Bug Screen
0.76
_
6
_
Bug Screen
0.76
7
Bug Screen
0.76
_-
"8-
Bug Screen
0:76-
9
Bug Screen
0.76
10
Bug Screen
0.76
11 -ung
Screen
0 7fi
1-
Bug Screen
-076-
1-1
Bug Screen
14
Bug Screen
07-6
11-5
Bug Screen
0:76-
--
16
Bug Screen
0:7`6-
_
17
Bug Screen
0.76
1"8
Bug Screen
-0:76-
--
-�" ---"
19
Bug Screen
0:76-
26
Bug Screen
0-7-6
21
Bug Screen
076
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
_
25
Bug Screen
0.76
7.3 4.5
4.0
0.1 4.0
4.0 -
26
_
Bug Screen
0.76
7.3 4.7
10.0
0.1 10.0
10.0 -
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
EnergyPro 3_1 By EnergySoft User Number: 5533 Job Number: �- Page: 13 of 19
Computer Method Summary (Part 3 of 3) C -2R
r&.Mrs. Clay Duncan -Addition 7/1/05
ojeci Title -Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
PERIMETER LOSSES
Type
F2 Insulation
Length Factor R -Val. Depth Location / Comments
Slab Perimeter
254 0.76
0.0 0 Existing Res
Slab Perimeter
59 0.76
0.0 0 Existing Res
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location Duct Thermostat Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.) R -Value Type Comments
Central Furnace
80%AFUE
Ducts in Attic 4.2 Setback HVAC -1
loydronic Piping i Pipe
System Name , ' Length
Cooling Equipment
Type (air conditioner,'
heat pump, evap. cooling)
Split Air Conditioner
Pipe Insul.
n;—f— Th; -L,
Minimum
Duct
Efficiency
Location
(SEER)
(attic, etc,)
13.0 SEER
Ducts in Attic
WATER HEATING SYSTEMS
Water Heater Water Heater Distribution
System Name Type Type
Duct Thermostat Location-/
R -Value Type Comments
4.2 Setback HVAC -1
Ratedl Tank Energy Fact? 1 Tank Insul.
# in Input Cap. or Recovery Standby R -Value
Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS; `
10L
F__,ergyPro
Run Initiation Time: 07/01/05 13:12:46 Run Code: 1120248766
3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 19 J
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Mr. & Mrs. Clay Duncan -Addition 7/1/05
YSTEM NAME FLOOR AREA
HVAC -1 1,414
ENGINEERING CHECKS
•outside
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK COIL HTG. PEAK] ;
CFM Sensible Latent CFM Sensible 1
Total Room Loads 1,904 32,380 0 665 — 28,634
Return Vented Lighting 0 j
Return Air Ducts 1,619 1,432
Return Fan 0 01
Ventilation 0 0 0 0 01
Supply Fan 0 0
Supply Air Ducts 1,619 1,432
r tin
(Heating System
i Output per System
89,000
Total Output (Btuh)
89,000
Output (Btuh/sqft)
62.9
Cooling System
Output per System
58,000
Total Output (Btuh)
58,000
Total Output (Tons)
4.8
' Total Output (Btuh/sgft)
TOTAL SYSTEM LOAD 1 35,618 0 31,497 I
41.0
-
Total Output (sgft/Ton)
292.6
Air System
HVAC EQUIPMENT SELECTION
CFM per System
2,000
CARRIER 38TRA06032 37,250 12,571 1 89,0001
_
Airflow (cfm)
2,000
Airflow (cfm/sqft)
1.41
Airflow (cfm/Ton)
413.8
Total Adjusted System Output 37,250 12,571 89,000,
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Air (%)
0.0
—_
Outside Air (cfm/sqft)
0.00
Note: values above given at ARI conditions
(Airstream I empera ures at I ime oTT ea ing ea
26.0 of 69.3 of 69.3 of
111.10F
Supply Air Ducts
Outside Air
i 0 cfm
Fan
110.5 OF ISupply
Heating Col
2000 cfm
__
ROOMS
70.0 of
69.3 O
Return Air Ducts
(Airstream I empera ures at Time ot Gooling ea
111.0 / 77.6 of 74.8 62.6 of 74.8 / 62.6 of 57.3 / 56.3 OF j
!
Supply Air Ducts
I Outside Air
O
0 cfm Supply Fan
Cooling Coil 58.0 156.6 of
2000 cfm
52.4% R.H. ROOMS I
C_ ___. _ . i ;
i 74.8162.6 of
74.0/62.3 OF
Return Air niirtt V19'
•
i
EnergyPro 3.1
By EnergySoft User Number: 5533 Job Number: Page: 15 of 19
ROOM LOAD SUMMARY
ROJECT NAME
Mr. & Mrs. Clay Duncan -Addition
DATE
7/1/05
iSYSTEM NAME
HVAC -1
FLOOR AREA
1,414
IROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Addition
i ion
1
1,904
32,380
0
1,904
32,380
0
665
28,634
PAGE TOTAL 1,904 32,380 0 1 665 28,634
TOTAL 1,904 32,380 0 665 28,634
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:16 of 19
ROOM HEATING PEAK LOADS
—
�p)ect
wlr.
Title
& Mrs. Clay Duncan -Addition
Date
17/1/05 i
Room Information Design Conditions
iRoom Name
(Floor Area
!Indoor Dry Bulb Temperature
Conduction
Addition
1,414
70 OF
Time
Outdoor
of Peak
Dry Bulb Temperature
AT of
=
=
=
=
=
=
=
-
=
_
=
-
=
_
_
—
=
_
=
_
=
Jan 12 am
26OF
Btu/hr
1_,728
422
Area
x
x
X
X
x
x
x
x
X
x
x
x
x
x
x
x
x
x
x
x
x
x
X
x
X
X
x
X
x
x
x
U -Value
X
x
X
x
x
x
x
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
X
X
X
x
x
x
x
R-38 Roof (R.38.2x14.16)
1,402.0
0.0280
44.0
Double Metal Tinted Default
12.0
0.8000
44.0
R-19 Wall (W.19.2x6.16)
1,189.2
0.0655
44.0
3,425
Double Metal Tinted Default
186.8
0.7200
44.0
5,918
7,368
2,565,
7,2091
_
- - -
i
—_
'
-----
—--- ,
---
------ -
- ---- - • - 1
Double Metal Tinted Default
197.0
0.8500
44.0
Double Metal Tinted Default
67.0
0.8700
44.0
44.5
Slab -On -Grade
perimeter= 162.0
i– -- ---- —
_
_
-- -
-_-
_--
'
-
_-_�---
---
-
----'
--
-
rx
-
--- x x – -- j
L- x x -------- ...
Items shown with an asterisk (') denote conduction through an interior surface to another room. 1
Ucf2allo
Page Total: 28,x341
Infiltration: x 1.064 x 1414 x 10.00 x 0.00 160 x �� = L 0�
Air Sensible Area Ceiling He g t ACH pT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28,634
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 17 of 19
RESIDENTIAL ROOM COOLING LOAD SUMMARY
•Mr. & Mrs: Clay Duncan -Addition
Project Title
r
I�
7/1/05
Room Name Addition
Design Indoor Dry Bulb Temperature: 740F
Design Outdoor Dry Bulb Temperature: 112°F
Design Temperature Difference: 380F
Conduction Area U -Value DETD' Btu/hr
X
X
X
X
X
X
X
X
X
X 55.0 = 2,159
X 38.0 = 365
X 34.6 = 2,693
X38.0 = 5,111
X 38.0 = 6,363
X 38.0 = 2,215
X =
X =
X =
1. Design Equivalent Temperature Difference (DETD) o Page Total 18,906
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain I Orientation Area SGF Area SGF SC Btu/hr
Skylight
(Skylight)
_
Window
(North)
Window
Window
Window
(North)
(North)
(North)
Window '
(North)
Window
(East)
Window
(East)
Window
(East)
Window , ;
(South)
( 0.0
X
X
x
x:All
x
x
x
x
x
X
15 +
1 +
1d.+
1 +
1 +
15' +
15+
1 +
15 +
15 +
( 0.0
( 0.0
(0.0
( 0.0
(_0.0
( 0.0
(-.0-
( 0.0
-.0.0
(
12.0
X
X
X
x
X
x
x
X
x
x
152)
X
X
X
X
x
x
0.448
=
=
=
=
=
=
=
=
__
=
818
10.8
'15)x
0.668
108
48.0
15)
0.657
473
52.5
15)X
0.668
526
80.0
15)x
0.657
788
11.2
15)
0.668
113
12.0
73)X
0.668
585
2,1581
45.0
73)
0.657
9.0
73)
0.668
0.657
4391
^
22.0
32)
_ 462
Sched. Page Total F7776,470
Internal Gain Frac. Area Heat Gain Btulhr
Lights 1.00 X 1,414 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Occupants 1.00 x 1,414 x 0 Btuh/occ. / 20,000 sgft/occ. = 0
Receptacle 1.00 x 1,414 x 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Process 1.00 x 1,414 x 0.000 Wattslsgft X 3.413 Btuh/Watt = 0
Infiltration: [ 1.00 x 1.064 x 1,414 x _ 10.00 x 0.00 / 60] 38
Schedile Air Sensible Area eiling Height ACH /\T.
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,380
Sched.
Latent Gain Frac. Area Heat Gain
Btu/hr
Occupants1.00 x 1,414 x 0 Btuh/occ. / 20,000 sgft/occ. = F_�0�
Receptacle 1.00 x 1,414 x 0.000 Watts/sgft x 3.413 Btuh[Watt = � 0
Process 1.000 x 1,414 x 0.000 Watts/sqft x 3.x13 Btuh/Watt =
_
Infiltration: [ 1.0� x _ 4,771 x 1,41 x _10.00 x 0.00 / 60] 0.00000 = OI
Schedule Air Latent Area Ceiling Height NCR pw
Fraction
[TOTAL
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0
EnergyPro 3.1 . By EnergySoft User Number: 5533 Job Number: Page: 18 of 19
C J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Mr. & Mrs. Clay Duncan -Addition 7/1/05
Project Title Date
Room Name Addition
Design Indoor Dry Bulb Temperature: 740F
Design Outdoor Dry Bulb Temperature: 112°F
Design Temperature Difference: 380F
Conduction Area U -Value DETDBtu/hr
x
X
x
X
(South)
(West)
=
=
=
_'
-�
Window
(West)
Window
Window ----' --
(West)
(West)
=
=
=
=
=
=
_
=
=
588
0.0
1. Design Equivalent Temperature Difference (DETD)
Page Total o]
Items shown with an asterisk (')denote conduction through an interior surface to another room. - ---- --
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Window
Window
(South)
(West)
Window
(West)
Window
(West)
Window
Window ----' --
(West)
(West)
=
=
=
=
=
=
_
=
=
588
0.0
15+
24.0
73)x
0.0
x
x
x
x
x
x
x
x
X
x
1
+
+
+
+
+
+
+
+
+
27.5
x
x
X
x
X
X
x
x)
X
x
32)
X
) x
)x
x
)x
)x
0.668
=
=
=
=
=
=
_
=
=
588
0.0
15+
24.0
73)x
0.657
1,151
0.0
1
15.0
73)X
0.657
719
719
! 719
3,108
------
_�
0.0
1
15.0
73)X
0.657
0.0
15
15.0
73)X
0.657
0.0
15
63.8
73
0.668
----
Sched. Page Total E 7,004
Internal Gain Frac. Area Heat Gain Btu/hr
F
ghts 1.00 X 1,414,X 0.000 Wafts/sgft x 3.413 Btuh/Watt_ccupants_ _ _ 1.00 x 1,414 x 0 Btuhlocc. / 20,000 sgftlocc.
Receptacle 1.00 X 1,414 x 0.000 Watts/sgft X 3.413 Btuh/Watt
Process 1.00 x 1,414ix 0.000 Watts/sgft x 3.413 BtuhfWatt
Infiltration: is x Air sen ose x rea414 x �i�n9 o 0o x Aco.00 / 60] �T 38 = of
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,380
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants Eli
x 1,414 x 0 Btuhlocc. I 20,000 sgft/occ.
Receptacle x 1,414 X 0.000 Wafts/sqft x 3.413 Btuh/Watt = 0�
Process -: x 1,414 x 0.000 Watts/sgft x I Btuh/Watt = _OJ
Infiltration: [ 1.00 x _ 4,77 11 X 1,414 X _ 10.00 x o.00 / 60] 0.00000 = ��
Sehe�lc uu a Air Latent Area Ceiling e.g ACA pW
• Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0
jEnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 19 of 19