Loading...
RER-13-108878-495 CALLE TAMPICO VOICE (760) 777-7125 LA QUINTA,.CALIFORNIA 92253 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760)777-7153 BUILDING PERMIT Date: 5/24/2016 Application Number: RER-13-1088 Owner. Property Address: 79860 RIVIERA DISTAN LLC APN: 762070002 79860 R Application Description: CONVERT 3RD CAR GARAGE TO BED/BATHROOM LA QUI a Property Zoning: Application Valuation: $0.00 MAY 2 4 ZGss Applicant: LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: :LIC -0103500 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars Was owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he r e did not build or improve for the purpose of sale.). s owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects w a co ractor(s) ed pursuant to t e actors' State License Law.). (m exempt under Sec. B P.C. fo r so yi Owner: ' CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Contra or: CITYOFLA QUINTA DISTA79860 .I pEVELOPMENTDEPART_M M 79860 RI�IE'RA^-- LA QUINTA, CA 92253 (760)771-1570 Llc. No.::LIC-0103500 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner ecome subject to the workers' compensation laws of California, and a e that, if I s ould be subject to the workers' compensation provisions of ection 3700 o e La e, I shall forthwith comply with those pro isions. / Date: J Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and -the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of ork for 180 days will subject permit to cancellation. I certify that I have read this application state t t the e i ormation is correct. I agree to comply with all city and cou k*esentatii ordinanc n t s relating to building construction, and hereby authorize rev s o th' enter upon the above-mezWoned property for inspecurp, es. �- Date:`. Y F S nature (Applicant.or Agent DESCRIPTION; FINANCIAL ; ,ACCOUNT-� s ,AMOUNT - ".PAID ''" PAID DATE: QTY PLAN CHECK/PERMIT EXTENSION PROCESSING 101-0000-42600 1 $97.17 $97.17 5/24/16 PAID BY METHOD ;, ' RECEIPT # . 'CHECK # -' CCTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for ADMINISTRATIVE: $97.17 $97.17 DESCRIPTION . ' ; a+ ACCOUNT QTY AMOUNT PAID PAID DATE'. HOURLY PLAN CHECK - YES 101-0000-42600 1 $70.00 $70.00 5/24/16 PAID:BYMETHOD Q ; „ RECEIPT # , CHECK # - CCTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for BLDG CITY STAFF - PER HOUR: $70.0.0 $70.00 DESCRIPTION • . ` = r_ ACCOUNT 'QTY AMOUNT: - PAID :PAID DATE, RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 5/24/16 PAID BY •METHOD RECEIPT # CHECK # CCTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION ACCOUNT QTY': AMOUNT: 'PAID " PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 5/24/16 " PAIDBY METHOD : RECEIPT #. CHECK # CCTD BY" LENCH DESIGN STUDIO INC CHECK, R15707 1327 RSE Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 DESCRIPTION ACCOUNT QTY ' AMOUNT PAID PAID DATE HOURLY PLAN CHECK 10160003428200 $367.50 $367.50 5/24/16 'PAID iBY. METHOD RECEIPT # . ° CHECK # CCTD BY, LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for HOURLY PLAN CHECK: $367.50 $367.50 DESCRIPTION , .. _t ACCOUNT QTY• :< . AMOUNT PAID.. ;PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09 5/24/16 PAID BY, METHOD f RECEIPT # • CHECK #, CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION ;•, ACCOUNTi a QTY' .: `AMOUNTi, . PAID PAID DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $4.83 5/24/16 'PAID BY " METHOD r,z .. 'RECEIPT #z CHECK # CCTD BY' LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION `, *, _ ACCOUNT, QTY AMOUNT ,s . PAID PAID DATE VENT FAN 101-0000-42402 0 $12.09 $12.09 5/24/16 "PAID By z METHOD RECEIPT # CHECK #,' CLTD.BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE s DESCRIPTION`' ACCOUNT.-,* QTY' AMOUNT *:PAID",' PAID DATE VENT FAN PC 101-0000-42600 0 $4.83 $4.83 5/24/16 . PAID BY- METHOD • RECEIPT # CHECK # CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for MECHANICAL: $33.84 $33.84 DESCRIPTION. " TY wAMOUNT c. PAID` .' `PAID DATEi. FIXTURE/TRAP 101-0000-42401 0 $48.36 $48.36 5/24/16 PAID BY -: a METHOD ° : ` .. RECEIPT # CHECK # CLTD BY.~_. LENCH DESIGN STUDIO INC CHECK 1115707 1327 RSE - * DESCRIPTION ACCOUNT CITY : _ " AMOUNT. PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $48.36 5/24/16 PAID BY';, " METHOD..E. _ RECEIPT # CHECK CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION ACCOUNT �, QTY AMOUNT ". PAID 1PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 5/24/16 "'. PAID BY .<< METHOD . `.. ;RECEIPT # ; . ; , CHECK # "` .. CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION ,ACCOUNT QTY AMOUNT. "PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 • $12.09 $12.09 5/24/16 PAID BY , METHOD RECEIPT# ., "'CHECK-# CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for PLUMBING FEES: $120.90 $120.90 DESCRIPTION _ = ACCOUNT • QY AMOUNT PAID.' PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $21.75 $21.75 5/24/16 PAID BY s ' .METHOD RECEIPT # . CHECK #: CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE 'DESCRIPTION ACCOUNT QTY < AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $17.40 5/24/16 PAID BY. - METHOD RECEIPT # OCHECK # CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION ACCOUNT QTY. :,._AMOUNT _ PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 5/24/16 PAID BY - METHOD :' + F RECEIPT # :CHECK # CLTD BY- LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE DESCRIPTION ACCOUNT . QTY' AMOUNT PAID w PAID DATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $134.88 5/24/16 BY r METH OD' F RECEIPT# CHECKS# CLTD BY, LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for REMODEL: $223.34 $223.34 x DESCRIPTION : �� -� ' r " ACCOUNT ` ' xQTY AMOUNT PAID PAID DATE SMI _ RESIDENTIAL 101-0000-20308 0 $1.50 $1.50 5/24/16 PAID BY " ` r . ,G METHOD. RECEIPT #' - . CHECK # CLTD BY LENCH DESIGN STUDIO INC CHECK R15707 1327 RSE Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.50 $1.50 Description: CONVERT 3RD CAR GARAGE TO BED/BATHROOM ADDITIONAL Type: BUILDING, RESIDENTIAL Subtype: REMODEL - Status: APPROVED Applied: 8/29/2013 Approved: 5/11/2016 JJO Parcel No: 762070002 Site Address: 79860 RIVIERA LA QUINTA,CA 92253 Subdivision: Block: Lot: Issued: Lot Sq Ft: Building Sq Ft: Zoning: Finaled: Valuation: $11,543.00 Occupancy Type: Construction Type: Expired: No. Buildings: No. Stories: No. Unites: Details: CONVERT, 3RD. CAR GARAGE TO BEDROOM & BATH. PLANS NEED TO BE UP -DATED TO THE 2013 CODES. APPLICATION EXTENSION GRANTED TO FEBRUARY 13, 2016. NOTE PLANS TO BE UPDATED WITH NEAL SEAL AND SIGNATURE BY ARCHITECT. ENERGY REPORT TO BE UPDATED TO 2013 CODES. PLANS EXPIRED AND WERE UPDATED TO NEW CODES. 11/13/2015 Printed: Tuesday, May 24, 2016 7:49:44 AM 1 of 4 J ., SYSTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE : COMPLETION DATE; NOTES `r respond to extension letter. NOTE JIM JOHNSON 11/12/2015. 11/13/2015 PLANS HAVE EXPIRED THE TITLE -24 & STRUC CALCS NEED TO BE UPDATED TO TODAYS CODES. NOTE JIM JOHNSON 5/4/2016 5/11/2016 WAITING. FOR STRUC RESPONSES TO BE RETURNED NOTE STEPHANIE KHATAMI 11/12/2015 11/12/2015 OWNER SUBMITTED AN EXTENSION LETTER. PLAN CHECK COMMENTS FROM CONSULTANT JIM JOHNSON 5/11/2016 5/11/2016 RECEIVED SKIP PICK UP PLANS AND TITLE 24. PLAN CHECK PICKED UP STEPHANIE GUMPERT 11/19/2015 11/19/2015 SKIP WAS GIVEN THE STAMPED APPROVED SETS & TITLE -24 WILL HAVE THE SETS REVISED AND RE STAMPED AND GET NEW STRUC CALCS. Printed: Tuesday, May 24, 2016 7:49:44 AM 1 of 4 J ., SYSTEMS PLAN CHECK SUBMITTAL RECEIVED STEPHANIE KHATAMI 4/26/2016 FINANCIAL 4/26/2016 REVISION SUBMITTAL RECEIVED - UPDATE 2013 BUILDING CODES. TELEPHONE CALL JIM JOHNSON 5/11/2016 INFORMATION 5/11/2016 CALLED SKIP TO INFORM HIM THE UP DATED PLANS AND SCHOOL FEES ARE READY TO ISSUE. CONDITIONS NAME TYPE ::: NAME ,%, ADDRE551 RECEIPT.# ` CONTACTS CITY STATE ZIP PHONE" ,FAX' EMAIL APPLICANT -LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA CA 92253 ( Printed: Tuesday, May 24, 2016 7:49:44 AM 2 of 4 sysTEMs FINANCIAL INFORMATION "° RECEIPT.# ` LTDw DESCRIPTION 41 ACCOUNT QTY -_ AMOUNT PAID PAID DATE CHECK METHOD ID BY e; _. �. u r'BY PLAN CHECK/PERMIT EXTENSION 101-0000-42600 1• $97.17 $97.17 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE STUDIO INC PROCESSING' Total Paid for ADMINISTRATIVE: $97.17 • $97.17 HOURLY PLAN CHECK - 101-0000-42600 1 $70.00 $70.00 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE YES STUDIO INC Total Paid for BLDG CITY STAFF - PER HOUR: $70.00 $70.00 RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE 1,0005E STUDIO INC RESIDENTIAL, FIRST 101-0000-42600 0. $47.86 $47.86 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE 1,000SF, PC STUDIO INC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 HOURLY PLAN CHECK 10160003428200 T $367.50 I $367.50 5/24/16 R15707 F1327 CHECK LENCH DESIGN RSE -1 STUDIO INC Total Paid for HOURLY PLAN CHECK: $367.50 $367.50 Printed: Tuesday, May 24, 2016 7:49:44 AM 2 of 4 sysTEMs {DESCRIPTION c' ACCOUNT QTY AMOUNT PAID PAID DATE- RECEIPT #, ;,CHECK# METHOD PAID BY D `$Y_ : APPLIANCE 101-0000-42402 0. $12.09 $12.09 5/24/16 R15707 1327 CHECK .LENCH DESIGN 'RSE REPAIR/ALTERATION STUDIO INC APPLIANCE 101-0000-42600 0 $4.83 $4.83 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE REPAIR/ALTERATION PC STUDIO INC VENT FAN 101-0000-42402 0 - $12.09 $12.09 5/24/16 R15707 1327. CHECK LENCH DESIGN RSE. STUDIO INC VENT FAN PC 101-0000-42600 0 $4.83 $4.83 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE STUDIO INC Total Paid for MECHANICAL:. $33.84 $33.84 FIXTURE/TRAP 101-0000-42401 0 $48.36 $48.36 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE STUDIO INC FIXTURE/TRAP PC 101-0000-42600 0 $48.36. $48.36 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE STUDIO INC WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE INST/ALT/REP STUDIO INC WATER SYSTEMLENCH 101-0000-42600 0 $12.09 $12.09 5/24/16 R15707 1327 CHECK DESIGN RSE INST/ALT/REP PC STUDIO INC Total Paid for PLUMBING FEES: $120.90 $120.90 REMODEL, EA.LENCH 101-0000-42400 0 $21.75 $21.75 5/24/16 R15707 1327 CHECK DESIGN RSE ADDITIONAL 500 SF STUDIO INC REMODEL, EA 101-0000-42600 0 $17.40. $17.40 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE ADDITIONAL 500 SF PC STUDIO INC REMODEL, FIRST 100 SF 101-0000-42400 0. $49.31 $49.31 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE STUDIO INC REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $134.88 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE PC STUDIO INC Total Paid for REMODEL: $223.34 $223.34 SMI - RESIDENTIAL 101-0000-20308 0 $1.50 $1.50 5/24/16 R15707 1327 CHECK LENCH DESIGN RSE STUDIO INC Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.50 $1.50 Printed: Tuesday, May 24, 2016 7:49:44 AM 3 of 4 SYS7[MS TOTALS: $1,107.14 $1,107.14 PARENT PROJECTS L Printed: Tuesday, May 24, 2016 7:49:44 AM 4 of 4 SYSTEMS BOND •• • 'AttachmentType CREATED�. OWNER_ ATTACHMENTS DESCRIPTION - PATHNAME w SUBDIR ETRAKIT ENABLED -e �e DOC 11/13/2015 JIM JOHNSON SCHOOL FEES 13- SCHOOL FEES 13- 0 1088.pdf 1088.pdf DOC 5/4/2016 JIM JOHNSON SCHOOL FEES 13- SCHOOL FEES 13- 0 1088.pdf 1088_1.pdf ` 1ST CHECK - 1ST CHECK - DOC 5/9/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf. DOC 11/12/2015 STEPHANIE KHATAMI EXTENSION REQUEST 11 EXTENSION REQUEST 11' 0 -12-15.pdf -12-15.pdf L Printed: Tuesday, May 24, 2016 7:49:44 AM 4 of 4 SYSTEMS N Bin # Cit/ Of La *Quinta - Building 8T Safety Division P.O. Box 1504, 78-495 Calle Tampico AUG — 2013 ' La Quinta, CA 92253 - (760) 777-7012 C OF (,q QUANTA Building Permit Application and Traj�� Perrpit # I o Project Address: J i SQA Owner's Name: A /� A. P. Number: (Z. d—) Address: Legal Description: City, ST, Zip: % U'1-X6A- 3 Z;;..Z Contractor: �I Telephone: ....>;<s:::::.>; . ....,..: :: :#:>s <.:..... Address: O Project Description: City, ST, Zip: C �2�►���- %-�� Q -E Telephone: p State Lic. # : City Lie. #•: Arch., Engr., Designer: J� l 1D Address: X Q City., ST, Zip: LA ( ZZ4-jp- Te h ne:Construction Type: cu ane State Lic. #: :F;.. :.. , `>`_:"'' '' ^ ° "' '' Proa (circle one): New Add'n Alter Repair Demo J type Name of Contact Per 2 Sq. Ft. :1-7 # St ries: #Units: Telephone # of Contact Person: 4 b0C,F> IC)y -r— Estimated Value of Project: �� APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES / Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person _ 10 Plan Check Balance. Title 24 Calc,. Plans picked up Construction Flood plain plan Plans resubmitted 13 Mechanical Grading plan 21" Review, ready or corrections 'ssue Electrical Subcontactor List Called Contact Person I B Plumbing Grant Deed Plans picked up ���• J f S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctio srissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees&T . or R 640 q d (66U eGT To a Permit Fees Bin >> City of La Quin to Buifding 8i Safety Division Pr O 78-495 Calle Tampico VOL -j La Quinta, CA 92253 - (760) 777-701,2 BuildingPermit A lication and Tracking Sheet PG g l�-Project Address v t e,te A T tOwner'sName:�AA C A. P. Number: Address:747 E t'/ Legal Description: City, ST, Zip: n — ,p 'Co tract or: - (V �( a V h n - oe Tele . P .....................................:....... Address:C5/7 7Project Desc_rriiptio City- ST, Zip:NJ Telephone: hone: State Lic. # :31 -5 -Cl 4 Z City Lic. Arch., Engr., Designer: Address: City, ST, Zip: C--- GIA I. IVf k 'VU -k, C^k_--' / -57 hone -/57701 e:Tele /�. 1 sfrac ton Type: State le Lic. # CIV ID 3S'o D e Dem orcle oew Add' AlterPoJ cttyPe ci Name of Contact Person: - Sq. # Stories: # Units: IF r� Telephone # of Contact Person: A ta ir�Q— Estimated•Value of Project: 5 , APPLICANT: -DO NOT WRITE BELOW THIS LINE # Submittal Rcq'd;'\ Rcc'd TRACKING PERMIT FEES Plan Sets � Plan Check submitted _Iteni . Amount Structural Cafes. ti� Reviewed, ready for corrections ' Plan Check Deposit Truss Cates. Called Contact Pcrson a Plan Check Balance, Title 24 Cates. Plans picked up ir Construction Flood plain plan Planresubmitted Mechanical Grading plan r god Review, ready for correctio s/issue J rElectrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked ups 11 S.M.I. H.O.A. Approval Plans resubmitted ' Grading IN IiOUSF:- Rcv ew, ready for corrections/issuc `,, Developer Impact Fee Planning Approval J Called Contact Person .i I.P.P. Pub. Wks. Appr Date or permit issueIr School Fees, y`+ 1 . Total Permit Fees koachella Valley Unified School District /83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Clay Duncan (PGA West) Owner's Name: Project Address: 79-860 Riviera., La Quinta, CA 92253 Project Description: Convert Garage to Living Space (Room Addition) APN: 762-070-002 Tract #: Type of Development: Residential XX Commercial Total Square Feet of Building Area: 307 Sq. Ft. Date: May 23, 2016 Phone No. Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is auger ci' to sign oa4whalf of the owner/developer. Dated: S- Z 3 — A alis- Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 307 EXEMPT $0.00 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement �Specific Plan 83-002 (PGA West) Sunrise Agreement 1986 states that all residential untis within this area are to be charged a fee of $628.00 for each unit constructed regardless of the square footage. his certifcate is exempt because it s 'for an addition only and the per unit fee was previoulsy paid Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia C. Torres, Facilities Analyst Signatu Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires th`a-rtthis District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/certificate ofcomp] iance rolm updated 3-2007 11/2010 CITY OF LA QUINTA. Burt Hanada,'Building Official Re: Building perm'it application 13-1088 November 12, 2015 We need an extension on this application. We are ready to pick it up and begin the work. Your early attention to this would be much appreciated. Sinc y Duncan Construction, Clay E Duncan 79860 Riviera, La Quinta CA 92253 clavduncan@hotmail.com 415-672-4681 b 0 's. to 60T op --o arGl� �PA4 fel,2512oi3 61 RUL (41(5 tJ16b0S To VP, 10 t9T6 0 01 ce, • f4i Cf P, • 541�.00( - OW &A. )O(Cao :vp 13y f�e(f. 16,Tj Lr J- 0, t! a a bt!5 LS -7*-v HE U NOV 12 2015 Cl*'f-( ,.A QUINTA Ty COMMUNI . DEVELOPMENT P.O. BOX 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c BUILDING-& SAFETY DEPARTMENT -(760)777-7012 FAX (760) 777-7011 PROPERTY OWNER'S PACKAGE M .Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER ". Dear Property Owner: An application for a buildinge` t has be ' subnjUtt�� your ii;04 yotrelf as builder of the property improvements specified at ��/ We are providing you with an Owner -Builder Acknowledgment a reformation Verification Form- to make/you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the ' Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this' form to us at our official address. indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to sign you understand or verify this information. �. 1. I undersiand' a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously, implies that the property owner is providing his or her own labor and material personally. I; as an Owner -Builder, inay be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. !2. I understand building permits are not required'to be signed by property owners unless they aie responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. %3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect' myself from potential financial risk by hiring a licensed Contractor and having the penste rmit filed in his or her name"iad of my own. :. f 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the tota] value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer under state and federal law. - 6. I understand if I am considered an "employer'• under state and federal law, I must register with the state and federal `government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to.serious financial risk. 7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential .'structures cannot - legally build them with "the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structuresdoes not"exceed four within any calendar year, or all of the work is performed under contract with a licensed.general building Contractor. r 0-g8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries 'sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at I- 800-32 (2752) or www.cslb.ca.gov for more information about licensed contractors. C li Jl0. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally, and financially 'responsible for proposed construction activity at the following address: M1. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as mell as employers. agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does. not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and. wish to hire Contractors, you will be responsible for verifying .whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, thi must be completed and signed by the property owner and returned to the agency responsible for issuing th ermit. t . A copy of the property owner's driver's license, form notarization, or other verification acceptable to t agency ir/ ired a presented when the permit is issued to verify the property owner's signature. Signature of property owner — Date: Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agents) to apply for, sign; and file. the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (o -r- Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare -under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: f1 copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owners signature. Property Owner's Signature: Date: STATE OF CALIFORNIA ALTERATIONS - HVAC EM CEC-CFIR-ALT-04-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CFIR-ALT-04-E Alterations - HVAC CZ 2, and 8-15 (formerly CF -IR -ALT -HVAC) (Page 1 of 1) Site Address: Enforcement Agency: Date Pre ared: Permitil: Equipment Type Equipment Efficiency New Ducting, Plenums, Lineset: Conditioned Thermostat Required R -value Floor Area (sq ft) ❑ Packaged System ❑ Evaporator Coil AFUE COP ❑ R-6 (CZ 2, 8-13) Ducting Served by system ❑ Setback ❑ Split System Mini Split ❑ Condensing Unit ❑ Compressor � 9 , ❑ R-8 (CZ 11, 14, ISJ Ducting 300 q s ft (If not already must SEER HSPFpresent ❑ R-6 (all CZ's) Plenums ❑ Furnace ❑ Linesetbe R-5 or R7.5) Lineset° installed) ❑ TXV EER HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand,, For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site. ❑ 1. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CFIR-ALT-02-E Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)2 -HERS, MECH-25-HERS Compressor, TXV, Lineset, CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS' Air Handler/Furnace2 (Can include new ducting) Installer Requirement: Duct leakage L15%, or <10% to outside, or seal all accessible leaks), Air Flow Z 300 CFM/ton, Refrigerant Charge. Exempted from duct leakage testing if: ❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building 1 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts' CF1R-ALT-02-E including Mini Split CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS2 9- CF3R: MECH-20-HERS, MECH-22-HERS; MECH-(23 or 24)-HERS2, MECH-25-HERS2 Mini Splits requir-,.Cf R -ALT -02-E CF- R -MFS and -(CE F3R) MECH-25-HERS Installer Requirement: Duct leakage < 6%, Fan Efficacy (.S8W/CFM), Air Flow z 350 CFM/ton (or alternative), Refrigerant Charge ❑ 3. All New Ducts with Replacement Required Compliance Documents to be left on site for Final: All New Ducts' and one or more of the following CFIR-ALT-02-E replaced: Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Compressor, TXV, Lineset, Furnace' CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Installer Requirement: Duct leakage < 6%, Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts' I CFIR-ALT-02-E, CF2R: MECH-20-HERS, CF3R: MECH-20-HERS Installer Required to: Duct leakage L15% or, < 10% to outside or, or seal all accessible leaks) ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. 'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc. 2 Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25 ' All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) ° R-5 W' thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter with insulation as the following 1.5-2T-25/8", 2.5-3T-2%", 3.5 to 4T-2%", 5T-4%" Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features.and-performance specifications for..the design. identified_on.this Certificate.of Compliance conform.to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. 5. The building design features or system design feature identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents/ worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit appl' ation. Responsible Designer e:' Responsible �esigherSignature: Date igned License: i 1 / & 506 3 Company : Address. City/State/Zip: �' Phone: `lne6630 i f l ve u�i For assistance br questions regarding the Energy Standards, cofttact the Energy Hotline at: 1-800-772-3300 , BUILDING ENERGY ANALYSIS REPORT PROJECT: Duncan Residence 79-860 Riviera La Quinta, CA Project Designer: I Report Prepared by: Joan D. Hacker Insu-form, Inc. 72875 Fred Waring Drive, Suite C Palm Desert, Ca 92260 760-345-1352 F CITY OF LA QUIN- t'qb Number: BUILDING & SAFETY DEPT, RECE/\/F:r-% APPROLCTION FOR CONSTR ate: APR 2 6 2016 DATEjBY5/2016 CIT' OFLA IW COMMUNITY E4 LOPMEN T The EnergyPro computer program has been uj to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 6.7 by EnergySoft User Number: 2655 ID: r co y C CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Calculation Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml CFI R -PRF -01 Page 1 of 9 GENERAL INFORMATION ENERGY USE SUMMARY .01 Project Name Single Fam Detached 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 79-860 Riviera Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 4751 15 Number of Zones 2 16 Slab AreaftZ ( ) 4751 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 9.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 HERS Provider: Report Generated at: 2016-04-25 12:22:19 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.37 0.58 -0.21 -56.8% Space Cooling 118.72 117.01 1.71 1.4% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 6.35 6.35 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 125.44 123.94 1.50 1.2% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 HERS Provider: Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Fam Detached Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Page 2 of 9 Calculation 9n Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • —None -- Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • — None — Domestic Hot Water System Verifications: • —None — ENERGY DESIGN RATING 01 This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use - # ';:_Energy;Desigri.Rating -. Margin Percent Improvement Total Energy (kTDV/f2-yr)' 162.73 161 23 ,M- 1.50 0.9% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 4751 1 6 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Living Conditioned Living Zone1 4444 9 DHW Sys 1 Addition Conditioned Living Zone1 307 9 DHW Sys 1 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Input File Name: Duncan Exist Additon.xml OPAQUE SURFACES 01 ATTIC Name Front Wall Left Wall Rear Wall Right Wall Roof Front Wall 2 Left Wall 2 Rear Wall 2 Roof 2 01 Name Attic Existing Living Attic Addition 02 03 Zone Construction Existing Living Default Wall 1978 to 1991 Existing Living Default Wall 1978 to 1991 Existing Living Default Wall 1978 to 1991 Existing Living Default Wall 1978 to 1991 Existing Living Default Roof 1978 to Pres Addition R-13 Wall Addition R-13 Wall Addition R-13 Wall Addition R-38 Roof Attic 02 El03 Construction Type Attic RoofExisting Living Ventilated Attic RoofAddition Ventilated CF1 R -PRF -01 Page 3 of 9 04 05 06 07 08 09 10 10 Azimuth Orientation Gross Area (ft) ( ) Window & DoorVerified y Area (ft) Tilt Verified Existing Existing 180 Front Cool Roof (deg) Status Condition 270 0.85 350 83.5868 90 Existing No 0.1 Left 180 81.0111 90 Existing. No 0 Back 350 149.366 90 Existing No 90 Right 180 - 69. 90 Existing _ No — 180 4444 Existing No Front 125 27 90 New N/A 270 Left 185 25.8024 90 New N/A 90 Right 50 0 90 New N/A 307 New N/A 04 05 06 07 08 09 10 Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Statu Verified Existing Cool Roof s Condition 0 0.1 0.85 No No Existi 0 0.1 0.85 No No ng New No No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - /Time: HERS HERS Provider: Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Calculation Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml CF1 R -PRF -01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Front -180) 4.0 3.2 0.727 9.3 0.40 0.24 Insect Screen (default) Altered N/A Window 2 Front Wall (Front -180) 5.8 6.0 0.977 34.0 0.40 0.24 Insect Screen (default) Altered N/A Window 3 Front Wall (Front -180) 6.0 8.0 0.485 23.3 0.40 0.24 Insect Screen (default) Altered N/A Window 4 Front Wall (Front -180) 3.5 3.2 1.518 17.0 0.40 0.24 Insect Screen (default) Altered N/A Window 5 Left Wall (Left -270) 3.0 5.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No Window 6 Left Wall (Left -270) 4.9 7.6 0.967 36.0 0.40 0.24 Insect Screen (default) Altered N/A Window 7 Left Wall (Left -270) 3.0 5.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No Window 8 Left Wall (Left -270) 3.0 5.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No Window 9 Rear Wall (Back -0) 3.9 5.5 1.557 33.4 0.71 0.73 Insect Screen (default) Existing No Window 10 Rear Wall (Back -0) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 11 Rear Wall (Back -0) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 12 Rear Wall (Back -0) 6.0 6.0 1 36.0 0.71 0.73 Insect Screen (default) Existing No Window 13 Right Wall (Right -90) 6.0 6.0 0.417 15.0 0.71 0.73 Insect Screen (default) Existing No Window 14 Right Wall (Right -90) 3.0 4.0 1 12.0 0.71 0.73 Insect Screen (default) Existing No Window 15 Right Wall (Right -90) 6.0 5.0 1 30.0 0.71 0.73 Insect Screen (default) Existing No Window 16 Right Wall (Right -90) 6.0 6.0 0.333 12.0 0.71 0.73 Insect Screen (default) Existing No Window 17 Front Wall 2 (Front -180) 5.0 4.5 1.2 27.0 0.40 0.24 Insect Screen (default) New N/A Window 18 Left Wall 2 (Left -270) 2.8 6.8 0.935 17.8 0.40 0.24 Insect Screen (default) New N/A Window 19 Left Wall 2 (Left -270) . 4.0 2.0 1 8.0 0.40 0.24 Insect Screen (default) New N/A Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 HERS Provider: Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Calculation Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 12 2 0.1 2 2 0 0 0 0 0 0 0 '0 0 Window 13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 17 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 19 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-2S 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation DatefTime: 12:21, Mon, Apr 25, 2016 Calculation Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml OPAQUE SURFACE CONSTRUCTIONS CF1 R -PRF -01 Page 6 of 9 01 02 03 04 05 06 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Assembly Layers Construction Name Surface Type Construction Type Framing Total Cavity. R -value Winter Design U -value 4444 12 None 0.8 No Existing Attic RoofExisting Living Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. none 0.644 • Cavity/Frame: no insul. /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) No New No • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 @ 16 in. U.C. R 11 0.103 • Exterior Finish: Wood Siding/sheathing/decking Default Roof 1978 to Pres Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 • Inside Finish: Gypsum Board Cavity/Frame: R-9.1 /2x4 Over Floor Joists: R-9.9 insul. Attic RoofAddition Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. R11 0.088 • Cavity/Frame: R-11 /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 • Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.020 • Sheathing/ Insulation: R11 Sheathing Cavity/ Frame: R-9.1 /2x4 Over Floor Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab Existing Living 4444 12 None 0.8 No Existing No Slab Addition 307 15 None . 0 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 HERS Provider: Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Calculation Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml CF1 R -PRF -01 Page 7 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Status Verified Existing Condition F. DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 06 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.5298 EF 40000-Btu/hr 0 0.04 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Living Zone1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 4751 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE Registration Number: . Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Input File Name: Duncan Exist Additon.xml HVAC - COOLING SYSTEMS Condition 01 02 03 04 OS Name SWstem Type EER Cooling Component 1 SplitAirCond - Split air conditioning system 10 Efficiency SEER Zonally Controlled 12 No HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Name Type Duct Leakage Insulation R -value Supply Duct Location Return Duct Location Bypass Duct Status Air Distribution System 1 Ducts located in attic Existing (not specified) 8.0 Attic Attic None Existing IAQ (IndoovAir Quality) FANS 01 02 CF1 R -PRF -01 Page 8 of 9 06 07 Multi -speed Compressor HERS Verification No N/A 09 10 Verified Existing HERS Condition Verification No N/A 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-04-25 12:22:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:21, Mon, Apr 25, 2016 Calculation Description: Title 24 Analysis Input File Name: Duncan Exist Additon.xml CF1R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan D. Hacker Company: Sign ate: Insu-form, Inc. 4/25/2016 Address: 72875 Fred Waring Drive, Suite C CEA/HERS Certification Identification (If applicable): City/StateQipim Desert, Ca 92260 y - - Phone: 760-345-1352 RESPONFS'I2BLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. ent with the information provided on other applicable compliance documents, 3. The building design features or system design features identified on this Certificate of Compliance are cVis;lbuilcling worksheets, calculations, plans and specifications submitted to the enforcement agency for approval wit permit application. Respons: lrgnpr Name Respon 'e esigner Signature: Company:. Dat Signed: Address: P� License: City/State/Zip:/17hon��O Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-25 12:22:19 'RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Duncan Residence Building Type m Single Family ❑ Addition Alone Date Orientation Area fr (ft) ❑ Multi Family I21 Existing+ Add ition/Alteration 4/25/2016 Project Address 79-860 Riviera La Quinta California Energy Climate Zone Total Cond. Floor Area Addition # of Units -Fac SHGC OverhangSidefins CA Climate Zone 15 4,7510 1 INSULATION Front (S) 83.6 0.400 0.24 2.0 none Area Altered Construction Type Cavity (ft) Special Features Status Slab Unheated Slab -on -Grade no insulation 4,444 Perim = 12' Existing Wall Wood Framed R11 678 none Roof Wood Framed Attic R 19 4,444 Existing Slab Unheated Slab -on -Grade - no insulation 307 Perim = 15' Existing Wall Wood Framed R 13 307 New Roof Wood Framed Attic R 38 307 Rigid=R-11.0 New S () 27.0 0.400 New FENESTRATION Orientation Area fr (ft) Total Area: U 436 Glazing Percenta e: 9 2 54 New/Altered Average U Factor 0.40 -Fac SHGC OverhangSidefins Exterior Shades Status Front (S) 83.6 0.400 0.24 2.0 none Bug Screen Altered Left (W) 45.0 0.710 0.73 2.0 none Bug Screen Existing Left (tM 36.0 0.400 0.24 2.0 none Bug Screen Altered Rear (N) 149.4 0.710 0.73 2.0 none Bug Screen Existing Right (E) 69.0 0.710 0.73 2.0 none Bug Screen Existing 9 S () 27.0 0.400 0.24 3.0 none Bug Screen New Left (tq 25.8 0.400 0.24 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status Living Zone Ducted Ducted Attic 8.0 Existing WATER HEATING Gallons Min. Eff Distribution Status 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of [he compliance a roach used. Exc tions ma a ly. Review the respective code section or more information. Building Envelope Measures: mditioned spaces are manufactured to limit air leakage. lows) have a label listing the certified U -Factor, certified Solar Heat Gain re uirements of §10-11l(a). 11 joints and penetrations are caulked and sealed. r Insulating Material. Indicate type and include on the CF2R. alues of the cool roofing material meets the requirements of §110.8(i) when the less when the installation of a radiant barrier is specified on the CFIR. r the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a permanently attached insulation using adhesive or mechanical fasteners. The er's installed design labeled R -value. g wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- )r or 0.037 maximum U -factor. r shall be installed on the conditioned space side of all insulation in all exterior neable insulation. he earth floor of the crawl space shall be covered with a Class I or Class II )ace, a Class I or Class II vapor retarder shall be placed over the earth floor of insulation from condensation, as specified in the exception to Section ate, for the insulation material alone without facings, no greater than 0.3%; .0 penn/inch, be protected from physical damage and UV light deterioration; is the requirements of $110.8 fined space from unconditioned space or outdoors shall have a maximum U- 1 fenestration shall not exceed 0.58. fetal or glass door covering the entire opening of the firebox. n outside air intake, which is at least six square inches in area and is it -fitting damper or a combustion -air control device. :r with a readily accessible control. air for cooling a firebox jacket, when that indoor air is vented to the outside s: is and all other regulated appliances are certified to the Energy Commission. elling units meet the air release valve, backflow prevention, pump isolation of § 110.3 (c)5. tural gas: fan -type central furnaces, household cooking appliances (appli- with pilot lights that consume less than 150 Btu/hr are exempt), and pool nee with ASHRAE, SMACNA or ACCA using design conditions specified ising units shall have a clearance of at least five feet from the outlet of any :et the setback requirements of § 110.2(c). o or less than the federal minimum standards shall be externally wrapped fR-12 or greater. :up storage tanks for solar water -heating systems, have R-12 external I insulation R -value is indicated on the exterior of the tank. >r unburied: the first 5 feet of hot and cold water pipes from the storage .arger, all piping associated with a domestic hot water recirculation system ; source to storage tank or between tanks, piping buried below grade, and xtures must be insulated according to the requirements of TABLE 120.3- e must be installed in a water proof and non -crushable casing or sleeve 'the enclosed pi2e and insulation. §110.6(a)1: Doors and windows between conditioned and §110.6(a)5: una Fenestration products (except field -fabricated win, Coefficient SHGC , and infiltration that meets thf § 110.7: Exterior doors and windows are weatherstripped; , §110.8(a): Insulation specified or installed meets Standards fc § 110.8(i): The thermal emittance and aged solar reflectance installation of a cool roof is s ecified on the CF1R § I I0.8(j): A radiant barrier shall have an emittance of 0.05 or Minimum R-30 insulation in wood -frame ceiling; § I50.0(a): c rafter roof alteration. Attic access doors shall have access shall be asketed to prevent air leakage Loose fill insulation shall conform with manufactw ffattic Minimum R-13 insulatfactor . Minimum R-19 insulation in raised wood -frame flo §150.0(g)l: In Climate Zones 14 and 16 a Class 11 vapor retarde walls, vented attics and unvented attics with air -pe §150.0(8)2: In Climate Zones 1-16 with unvented crawl spaces 1 va or retarder. In a building having a controlled ventilation crawl s §150.0(g)3: the crawl space to reduce moisture entry and protect 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption r have water vapor permeance rate is no greater than and when installed as part of a heated slab floor mee § 150.0(q): Fenestration, including skylights, separating condi6 factor of 0.58; or the wei ted avers a U -factor of a Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable in § 150.0(e)IB: Masonry or factory -built fireplaces have a combustic e ui ed with a readily accessible, operable, and tigl §150.0(e)IC: Masonry or factory -built fireplaces have a flue damp §150.0(e)2: Continuous burning pilot lights and the use of indoor of the building, are -prohibited. Space Conditioning, Water Heating and Plumbing System Measure §110.0-§110.3: HVAC equipment, water heaters, showerheads, fauce §I I0.3(c)5: Water heating recirculation loops serving multiple dv valve, and recirculation loop connection requirement; Continuously burning pilot lights are prohibited for § 110.5: n; ances without an electrical supply voltage connection ands a heaters. §150.0(h)l. Heating and/or cooling loads are calculated in accord, in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor sonde dryer vent. § 150.0(i): Heating systems are equipped with thermostats that m §150.00)]A- Storage gas water heaters with an energy factor equal i with insulation having an installed thermal resistance ( §150.00)IB: Unfired not water tanks, such as storage tanks and bac; insulation or R-16 internal insulation where the interne For domestic hot water system piping, whether buried §150.06)2A: tank, all piping with a nominal diameter of 3/4 inch or regardless of the pipe diameter, piping from the heating all hot water pipes from the heating source to kitchen f A. §150.00)2B.- All domestic hot water pipes that are buried below gray that allows for installation rem--- -4 2013 Low -Rise Residential Mandator §150.00)2C: Pipe for cooling system lines shall be insulated as systems or hot waters stems with pressure > 15 r § 150.00)3: §150.00)3A: §150.00)3B: §150.0(n)]: § 150.0(n)2: §150.0(n)3: Measures Summary cified in §150.0 ' A. Piping insulation for steam and hydronic heating shall meet the requirements in TABLE 120.3-A. Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I or Class II vapor retarding facing, or the insulation shall be 'installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal. openings greater than % inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be coin ressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other re uirements s ecified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers exce t combustion inlet and outlet air o nin s and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential !Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an'rflow from the dwelling, through the air handler fan and delivered to the dwelling, of 2: 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing in accordance with Reference Residential Appendix RA3 All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems .are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation. airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting• a permanent weatherproof plate or card with operating instructions and shall not use electric resistance heatine_ 2.013 Low -Rise Residential Mandatory MPa Q» rPC Cn m m a ry § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric -demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §1:50.0(k)IC- § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting ern electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0 2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §I50.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an overide or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, J- ro ammed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the a122licable requirements in §110.9, §130.0, §130.2, $130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable re uirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no mare than 5 watts of power as determined according to §130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in §110.9, $130.0, § 130.1, $130.4, §140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: 1. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall com 1 Y with the requirements of §110.10 through §110.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area § 110.10(6)2. All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. §110. 10(d): A copy of the construction documents or a comparable document indicating the information from §110. 10(b) through § 110.10(c) shall be 2rovided to the occupant. § 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a §I 10.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Duncan Residence Date System Name 4/25/2016 Living Zone Floor Area 4,751 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output perSystem 70,000 Total Room Loads 2,371 51,176 4,447 673 35,364 Total Output Btuh 140,000 Return Vented Lighting 0 Output Btuh/s ft 29.5 Return Air Ducts 2,954 1,738 Cooling System Return Fan 0 0 Output perSystem 42,000 Ventilation 0 0 01 0 0 Total Output Btuh 84,000 Supply Fan 0 0 Total Outpu t 7.0 Supply Air Ducts 2,954 1,738 Total Output 17.7 Total Out 678.7 TOTAL SYSTEM LOAD 57,084 4,447 38,841 Air System CFM perSystem 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 2,600 Existing HVAC 62,026 11,475 140,000 Airflow cfm/s ft 0.55 Airflow cfm/Ton 371.4 Outside Air % 0-0% Total Adjusted System Output 62,026 11,475 140,000 Outside Aircfm/s ft 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 120 OF 120 OF Outside Air 0 cfm Heating Coil Supply Fan 2,600 cfm 119 OF 69 OF ROOM- 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/64°F 57/55°F 57/55 OF Q Outside Air 0 cfm Cooling Coil Supply Fan 58 / 56 °F 2,600 cfm 45.8 % R1OO:M 79 / 64 °F 78 / 64 OF EnergyPro 6.7 by EnergySoft User Number- 2655 Run Code: 2016-0425712:23:36 /D: Page 17 of 17