07-2136 (AR)P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/29/07 Application Number: 07-000021361 Owner: Property Address: 79890 RIVIERA', CAPOBIANCO PETER T APN: 762-070-006- - - 40 SEAVER-ST NO 10 Application description: ADDITION - RESIDENTIAL WELLSELEY HILLS, MA 2 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 150000 Contractor: Ot/r .3 p Applicant: ' Architect or Engineer: EDWARDS CONSTRUCTION IN��� B 001 J 51455 DESERT CLUB D Irfj�O�(,y � LA QUINTA, CA 92253 '�A'r_�r �lffg�p (760)777-8202 Lic. No.: 684857 �\ LICENSED CONTRACTOR'S DECLARATION • - I hereby affirm under penalty of perjury that lam lice d under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of usi ss an rot §s onals Code, and my License is in full force and effect. License Class: B 1 License -No.: 684857 Date: 1 Contracto . v 0 4N R UILDER DECLARATION I hereby affirm under penalty of perjury that I am etefript from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Profe 16ns Code: Any city or county that requires a permit to .construct, alter,.. improve, demolish, or repair any structure; prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State , License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . , B.&P.C. for.this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under, penalty of perjury one of the following declarations: _ I have and will.maintain a certificate of consent to'self-insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier GRANITE STATE Policy Number 3368904 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, ' oul be me s ject to the workers' compensation provisions of Section 3700 of the L bor , I shal o J ith comply wit fose provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' CO PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED. FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers,'agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the ab formion is correct. I agree to comply with all city and county ordinances and state laws relating to bu' c n ctfo and hereby authorize representatives of this county to enter upon the above-mentione p t or i s ibn urposes. - Date: v Signaturer(Applicant or Agent): Application Number . . . . . 07-00002136 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 814.50 Plan Check Fee 529.43 Issue Date . . . . Valuation 150000 Expiration Date 4/26/08 Qty. Unit Charge Per Extension. • BASE FEE 639.50 50.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 175.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 42.25 Plan Check Fee 10..56 Issue Date Valuation . . . . 0 Expiration. Date 4/26/08 Qty Unit Charge Per Extension BASE FEE 15.00 531.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 18.59 433.00 -------------------------------- .0200 ELEC =------------------------------------------- GARAGE OR NON-RESIDENTIAL 8.66 Permit . . MECHANICAL Additional desc . Permit Fee . . . . 55.00 Plan Check Fee 13.75 Issue Date Valuation 0 Expiration Date 4/26/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 ---------------------------------------------------------------------------- 6.5000 EA MECH VENT FAN 13.00 Permit PLUMBING Additional desc . . Permit Fee . . . . 39.00 Plan Check Fee 9.75 Issue Date . . . . Valuation . . . 0 Expiration Date 4/26/08 Qty Unit Charge Per Extension BASE FEE 15-00 3.00 6.0000 EA PLB FIXTURE. 18.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 LQPERIIIIT Application Number .. . . . . 07-00002136 Permit . . . . . .. PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB GAS PIPE 1-4 L OUTLETS 3.00 --------------------------------------- Special Notes and Comments ----------------------------=------- 531 -SQ. FT. ADDITION AND 433 SQ. FT. GARAGE WITH INT REMODEL. ---------------------------------------- Other Fees . . . . . . . . . --------------------------------=--- ENERGY REVIEW FEE 52.94 STRONG MOTION (SMI) - RES 15.00 Fee summary Charged -- - - - - - - - - - - - - - ------ - - - - -- Paid Credited ---- - - - ---- - - - - ---- Due -- - - - - - - Permit Fee Total 950.75 --- ..00 .00 950.75 Plan Check Total 563.49 .00. .00 S63.49- 63.49Other OtherFee Total 67.94 .00 .00 67.94 Grand Total 1582.18 .00 .00 1582.18 LQPEIL,NIIT Bin # ;11 City of La Quinta Building ex Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:� U I Owner's Name: A. P. Number:Address: P 7 Legal Description: L-07 City, ST, Zip: ak- Contracto1015 Telephone: Address: Project Description: City, ST, Zip: 4X>t>t77(D&J Telephone: 't7-7-7- 871r-)E�- IMA MOM— I State Lic. # City Lic. #: VUid2:tt=. Designer:�;F Address:14 AN % 0 `low. low City, ST. Zi+;( tef Telephone: Construction Type: Occupancy: State Lic. #: Project type (circle one): New Add'n- Alter Repair Demo Name of Contact Person: Sq. Ft.: ies: # Units: Telephone # of Contact Person: -,?7 7 E710 TEstimated Value of Project: CC7 APPLICANT: DO.NOT WRITE BELOW THIS LINE # Submittal Req'd Ree'd TRACKING PERMIT FEES Plan Sets Plan Check submitted, Item Amount Structural CaIcs. di Reviewed, ready for corrections A Plan Check Deposit Truss Cales. oc 'Called Contact Person &W '8(1 f6-7 Plan Check Balance Energy CaIcs. Plans bickcd up 4VT Alft'i Construction Flood plain plan Plans resubmitted 4 Q Mechanical Grading plan 2"a Review. ready �Cr correction issue Electrical Subcontactor List Called Contact P Plumbing 'Grant Deed Plans picked up S-M-I- H.O.A. Approval 911.1 Plans resubmitted 71 Grading INHOUSE:-, Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees I Total Permit Fees ,AtL4AC-, --ft VCA gaZ" If- 4-U p(s. r-,-F-c---- 91 1�i 4A Z 9W. -O -117AD4 1410101 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Cap b a o This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date: 10/30/07 Owner's Name: Capobianco Phone No. ( Project Address: 79-890 Riviera, La Quinta, CA 92253 Project Description: Room Addition to Existing House APN: 762-070-006 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 433 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized tgsigp on behalf of the owner/developer. Dated: 10/30/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. Amount per Sq.Ft. Amount Collected 433 sq. ft. $ 2.63 $ 1,396.53 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereoE This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T May 23, 2007 Mr. & Mrs. Peter Capabianeo 40 Seaver Street, Apt. 10 Wellesley, MA 02481-6724 a <; .. ,.... PGA WEST n' sIDENT AL ASSOCIATION, INC. 42-600 CAROLINE COURT, SUITE 101 PALM DESERT, CALZFORNIA 92211 PHONE (760) 776-5100 - FAX (760) 716-5111 Reference: 79-890 Riviera, La Qukta Architectaral Requast for driveway, golf cart garage, dining room addition, master bedroom/bathroom addition and additional landscaping Dear W. & Mn. Capabimoo: The Architectural Committee and the landscape Committee respectively reviewed and approved your plans as referenced above. All concrete used in PGA WEST II Residential Association shall be in accordance with that shown in "Concrete Mie', Appendix 3, enclosed for your convenience. The Landscape Committee has the following comments: • Added irrigation must be drip system with rigid pipe, schedule 40; one dripper per shrub.' • Your contractor must warranty the trees and shrubs for one year. • The Association owns, and the landscape contractor operates, a TORO irrigation system. Modifications to existing, or installation ofnew irrigation'equipment, shall be coordinated with the landscape committee. All sprinklers shall be Rainbird,1804 or 1806 SAM body assembly. • Only low voltage lighting with a maximum of 50 watts may be used for exterior lighting applications. All added lighting shall be maintained by the homeowner and shall not be tied into Association electricity. • Added shrub irrigation shall be connected to a separate station on the irrigation tm= so it will not be watered with the naf. the Committee is only fo"eneral con ormgmwe with the Archkeeutral Rules. It is the rea�onsibtWt of the owner to fully understand and conform to the Architectural Rules crheHa whether or not all deficiencies are noted during review. It is also the owner'sfull responsibility to field verify all mastine conation& The Committee's decision with reward to nroiect dedw will be &d Please refer to the Architeewral Rules for all required submittals Approvals Sven by the Architectural Committee are good for only six months from the date on tha approval letter. If construction has not commenced within nix months alter fire project approval date, a new application must be submitted. Please contact Luis Umana, Sunshine Landscape at 760/346-3999 and Carol Fuller, the Association Manager, prior to any irrigation modifications associated with this change. Damage to the landscaping, i.e., shrubs, trees, flowers and tuff is the responsibility of the contractor. The original landscaping trust be brought back to its original condition when the project is completed. TITLE 24 REPORT Title 24 Report for: Capobianco Residence -Alteration 79-890 Riviera -PGA West La Quinta, CA 92253 Project Designer: Robert A. Pitchford, Design & Drafting 41-625 Eclectic Dr., Ste A2 Palm Desert, Ca 92260 (760) 346-2856 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 9 Job Number: Date: 10/2/2007 OCT 12 2007 IU he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 1 1 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads CITY OF LA QUINTA BUILDING & SAFETY DEPT. FOR APPROVED NST UCTION _z 1 2 3 9 11 12 14 16 19 I EnergyPro 4.3 by EnergySoft I Job Number: User Number: 6712 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R oject Title A Riviera-P(IA West I n Quinta 10/2/2007 Date -AAO Project Address Building Permit # Sr nesian &Title 24 (760) 200-4780 Documentation -Author Telephone Plan Check/Date FneravPro Complli race Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 9.36 5.09 4.28 Space Cooling 160.19 137.29 22.91 Fans 21.83 18.56 3.27 Domestic Hot Water 9.73 9.73 0.00 Pumps 0.00 0.00 0.00 Totals 201.12 170.67 30.45 Percent better than Standard: 15.1% Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: ❑ Addition [X-1 Existing + Add/Alt (S)180 deg Natural Gas Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Fenestration: Average Ceiling Height: Area: 749 ft2 Avg. U: 0.80 Number of Dwelling Units: Ratio: 21.2% Avg. SHGC: 0.62 Number of Stories: (one ZONE INFORMATION # of Thermostat one Name Floor Area Volume Units Zone Type Type Fxdstng HVAC -1 3 22322 3? 2sn _0 91 Conditioned Setbacls� HVAC -3 311 3110 0.09 Conditioned SPthack OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 3003 n 049 R-19 R-0 0 x_22 Wall Wood 533 _n int R-13 R-0.0 a gn Wall Wood R93 0.102 R-13 R-0.0 g0 gn Wall Wnnd 147 _n 102 R_13 R -n n g0 An W211 Wood 46 _Q 102 R-13 R-0.0 135 g0 Wall Wood 717 0102 R-13 R-0.0 180 An Wall Wnnd 75 n im R_13 R-0 0 n C)Q Wall Wnnd 46 n 102 13_13 R-0 0 225 gn W211 Wood R76 0102 R-13 R_0 0 270 _9.0 Roof Wood 220 0025 R_38 R-0.0 Q _2Q Wall Wnnd 3R n n69 X21 R-0 0 An Wall Wnnd 130 n o69 R_91 R -n n 1R0 An Wall Wood 135 n n69 _R-21 R-0.0 270 gQ Rnnf Wood 311 n n95_ R-38 R-0.0 2n Wall Wood 150 0.069 _R-21 R-0.0 cm W211 Wood 213 0069 R-21 R-0 0 1R0 gQ Wall Wnnd 15n n 069 R_91 R -n n 27n An 3,534 ft2 3,003 ft2 0 ft2 3,534 ft2 10.0 ft 1.00 Vent Hgt. Area 2 n/a _2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Pane:3 of 23 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R 10/2/2007 Date True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 1 2 Window Window Rear Rear (N)195 (N) 5 0_870 NERC 0_70 NERC 0 qQ Existing Double Metal Clear 48.0 0.870 NFRC 0.70 NFRC 0 90 Existing Double Metal Clear Existing Existing Residence Residence 3 Window Rear (N) 17.3 0.870 NFRC 0_70 NFRC 0 90 RemovedDouble Metal Clear Existing Residence 4 Window Rear (N) 33.6 0.870 NFRC 0.70 NFRC 0 90 RemoveMouble Metal Clear Existing Residence 5 Window Rear (N) 17.1 0.870 NFRC 0_70 NFRC 0 90 RemoveMouble Metal Clear Existing Residence 6 Window Rear (N) 93.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Metal Clear Existing Residence L Window Rear (N) 28.3 0_870 NFRC 0_70 NFRC _� 90 Existing Double Metal Clear Existing Residence 8 Window Rear (N) 61.0 0.870 NFRC 0.70 NFRC 0 90 Existing Double Metal Clear Existing Residence 6 Window Rear (N) 2.5 0_550 116-A -OM 116-B _0 90 Existing Glass Block Existing Residence 1Q Window Rear (N) 20.0 0_620 NFRC 0_40 NFRC 0 90 Existing Double Thermal Break Clear Existing Residence 11 Window Right (E) 27.8 0.870 NFRC 0_70 NFRC 90 90 Existing Double Metal Clear Existing Residence 12 Window Right (E) 20.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Metal Clear Existing Residence -U Window Right ()a 29.0 _ 0.870 NFRC _Q10 NFRC 90 _;3Q Existing Double Metal Clear Existing Residence 14 Window Right (E) 40.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Metal Clear Existing Residence 15 Window Right (E) 20.0 0.870 NFRC 0_70 NFRC 90 90 RemoveMouble Metal Clear Existing Residence 16 Window Right (E) 8.0 0.870 NFRC 0_70 NFRC 90 90 RemovedDouble Metal Clear Existing Residence 17 Window Right (E) 34.9 0.870 NFRC 0_70 NFR[: 90 90 RemovedDouble Metal Clear Existing Residence 18 Window Right (SE) 14.0 0.620 NFRC 0_40 NFRC 135 90 Existing Double Thermal Break Clear Existing Residence JR Window Front (S) 7.5 0_870 NFRC 0_70 NFRC 180 90 Existing Double Metal Clear Existing Residence 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING JA IV Reference Condition Status Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Lena Hgt. LEA. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 Concrete, Heavyweight Bug Screen 0.76 26-A1 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 1,046 3.50 28 0_98 2 26-A1 Existing Existinq Residence / Slab on Grade Concrete, Heavyweight 1,957 3.50 28 0_98 0 26-A1 Existing Existing Residence / Slab on Grade Concrete, Heavyweight 220 3.50 28 0_98 0 26-A1 New Dining Addn / Slab on Grade Concrete, Heavyweight 311 3.50 28 0_98 0 26-A1 New Master Bdrm Adn / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 153 None No Insulation 26-A1 Existing Existing Residence Slab Perimeter 1,957 None No Insulation 26-A1 Existing Existing Residence 43 None No Insulation 26-A1 New Dining Addn AWPerimeter b Perimeter lqw 55 None No Insulation 26-A1 New Master Bdrm Adn Run Initiation Time: 10/02107 20:28:45 Run Code: 1191382125 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:4 of 23 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Title 10/2/2007 Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 2R 21 Windnw Window Front Front (-,;)_ (S) 75 087 NFRC QID NFRC 180 -9.0 xistina Douhle Metal Clear 24.0 0.870 NFRC 0.70 NFRC 180 90 Existing Double Metal Clear -Existing-Residence Existing Residence 22 Window Front (S) 34.0 0.870 NFRC 0_70 NFRC 180 90 Existing Double Metal Clear Existing Residence 23 Window Rear (N) 18.3 0.870 NFRC 0.70 NFRC 0 90 RemovedDouble Metal Clear Existing Residence 24 Window Rear (N) 36.7 0.870 NFRC 0_70 NFRC 0 90 RemovedDouble Metal Clear Existing Residence 25 Window Rear (N) 18.3 0.870 NFRC 0_70 NFRC 0 90 RemovedDouble Metal Clear Existing Residence 2& Window Front (SW) 14.0 0.620 NFRC 0.40 NFRC 225 90 Existing Double Thermal Break Clear Existing Residence 27 Window Left (W) 19.5 0.870 NFRC 0.70 NFRC 270 90 Existing Double Metal Clear Existing Residence 2$ Window Left (W) 7.0 0.870 NFRC 0.70 NFRC 270 90 Existing Double Metal Clear Existing Residence 2a Window Left (W) 19.5 0.870 NFRC 0.70 NFRC 270 90 Existing Double Metal Clear Existing Residence M Window Left (W) 19.5 0.870 NFRC 0_70 NFRC 270 90 Existing Double Metal Clear Existing Residence 31 Window Left (W) 19.5 0.550 116-A 0_55 116-B 270 90 Existing Glass Block Existing Residence Window Left (W) 33.6 0.870 NFRC J110 NFRC 270 _Q-RemovedDouble Metal Clear Existing Residence 33 Window Left (W) 1.0 0.550 116-A 0_55 116-B 270 90 Existing Glass Block Existing Residence 34 Window Left (W) 4.0 0.870 NFRC 0_70 NFRC 270 90 Existing Double Metal Clear Existing Residence 35 Window Left (W) 4.0 0.870 NFRC 0_70 NFRC 270 90 Existing Double Metal Clear Existing Residence 36 Window Rear (N) 17.5 0.620 NFRC 0_40 NFRC 0 90 New Double Thermal Break Clear Dining Addn 37 Window Rear (N) 40.0 0.790 116-A 0_59 116-B 0 90 New Double Metal Tinted Dining Addn ,$ Window Rear (N) 35.0 0.620 NFRC 0.40 NFRC 0 90 New Double Thermal Break Clear Dining Addn 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang # Exterior Shade T_vve SHGC Hgt. Wd. Len. Hgt. LExt. REA 20 Bug Screen 0.76 Ti Bug Screen 0.76 22 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 Left Fin Dist. Len. THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Right Fin Dist. Len. Hgt. PERIMETER LOSSES Type Length R -Val. Insulation Location Condition JA IV Reference Status Location/ Comments Run Initiation Time: 10/02/07 20:28:45 Run Code: 1191382125 EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page:5 of 23 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R 10/2/2007 Date True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments _3.9. Window Left (W) 35 0 0 620 NFRC -0-40 NFRC 270 __M Altered Double Thermal Break Clear Dining Addn 40 Existing 0.870 NFRC 0_70 NFRC Double Metal Clear pre -altered for above 41 Window Front (S) 7.0 0.550 116-A 0.55 116-B 180 90 New Glass Block Master Bdrm Adn 42 Window Front (S) 30.0 0.620 NFRC 0.40 NFRC 180 90 New Double Thermal Break Clear Master Bdrm Adn 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 41 Bug Screen 0.76 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES TVDe Le Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments Run Initiation Time: 10102/07 20:28:45 Run Code: 1191382125 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:6 of 23 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R V: Title AC SYSTEMS Date 10/2/200 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Existing HVAC -1 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC -3 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location Existing HVAC -1 Ducted Ducted Attic HVAC -3 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 Existing No 49 NPw Nn WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 2 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Robert A. Pitchford Design & Draftipq Address: 41-625 Ecl r.. Ste Telephone (sig Enforcement Agency Name: Title/Firm: Address: Telephone Documentation Author Name: Tim Scott _ Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Z Palm D sertCA 9 211 Telephone: 7 0-4780 ate) (signature) date) millipgriature) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF-1 R .Capobianco Residence-Alteration 10/2/2007 oject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on the aaequacy of the special justitication ana aocumentation suomittea. Plan I Field HIGH MASS Design - Verify Thermal Mass: 1046 sqft Covered Slab Floor, 3.50" thick at Existing Residence HIGH MASS Design - Verify Thermal Mass: 1957 sqft Exposed Slab Floor, 3.50" thick at Existing Residence HIGH MASS Design - Verify Thermal Mass: 220 sqft Exposed Slab Floor, 3.50" thick at Dining Addn HIGH MASS Design - Verify Thermal Mass: 311 sqft Exposed Slab Floor, 3.50" thick at Master Bdrm Addn HERS Required Verification Items in this section'require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:8 of 23 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit • documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ f§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire cpening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified b' the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:9 of 23 Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated • into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • 0 DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment X 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 10 of 23 Residential Kitchen Lighting Worksheet WS -5R Title 10/2/2007 Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 1 26w Compact Fluorescent Triple 4 Pin Yes X1 No 28.0 x 8 224 or Low Voltage Halogen Mag Yes No X 39.0 x 5 = or 195 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes L No x = or Yes I No x or Yes No x = or Yes I No x = or Total A: 224 B: 195 COMPLIES IF A z B YES ® NO ❑ 0 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:11 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Capobianco Residence -Alteration 10/2/2007 STEM NAME FLOOR AREA Existing HVAC -1 3,223 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 4,237 68,743 4,073 4,845 126,507 0 13,817 18,122 0 0 0 0 0 0 0 0 0 13,817 18,122 96 378 4 073 162 752 Existing HVAC System 93,339 13,800 142,000 Total Adjusted System Output93,339 13,800 142,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 ann EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 65.8 of 65.8 of 98.7 of 0: Supply Air Ducts Outside Air 0 cfm 94.5 of Supply Fan Heating Coil 4050 cfm ROOMS 65.8 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Cooling Peak 111.0 177.6 OF 81.2/66.0 OF 81.2/66.0 OF 59.5/58.3 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 62.8 / 59.5 of 4050 cfm 50.0% R.H. ROOMS 81.2/66.00F 78.0/65.0 OF Return Air Ducts EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Pane: 12 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Capobianco Residence -Alteration 10/2/2007 STEM NAME FLOOR AREA HVAC -3 311 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 340 6,437 239 136 5,632 0 1,145 723 0 0 0 0 0 0 0 0 0 1,1451 1 723 8 728 1 039 Carrier 24ACA436/58CVX070 24,986 7,301 Total Adjusted System Output 2x,986 7,301 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 7 077 51,000 51,000 Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Heatina Peak) I 26.0 OF 69.4 OF Outside Air 0 cfm 69.4 OF 11.0 / 77.6 OF Outside Air 0 cfm 78.9/65.2 °F 109.4 OF Heating Coil ROMETRICS (Airstream T 109.4 OF 0 Supply Air Ducts Supply Fan 108.8 OF 1200 cfm ROOMS 70.0 OF Return Air Ducts I 78.9 / 65.3 OF M 59.3 / 58.2 OF Cooling Coil Supply Fan 1200 cfm 59.3 / 58.2 OF Supply Air Ducts 60.2/58 . 5 OF 49.9% R.H. ROOMS 78.0 / 64.9 OF Return Air Ducts '*I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 13 of 23 1 ROOM LOAD SUMMARY PROJECT NAME DATE Capobianco Residence -Alteration 10/2/2007 STEM NAME FLOOR AREA ExistingHVAC-1 3,223 PAGE TOTAL 1 4,237 68,743 4,073 4,845 126,507 TOTAL 1 4,237 68,743 4,073 4,845 126,507 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 14 of 23 4 4 4 ROOM LOAD SUMMARY PROJECT NAME Capobianco Residence -Alteration DATE 10/2/2007 STEM NAME HVAC -3 FLOOR AREA 311 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Bdrm Adn Master Bdrm Addn 1 340 6,437 1,039 340 6,437 1,039 136 5,632 PAGE TOTAL 1 340 6,437 1,039 136 5,632 TOTAL 1 340 6,437 1,039 136 5,632 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 15 of 23 ROOM HEATING PEAK LOADS 6 0 ject Title anohianco Residence -Alteration 10/2/2007 Room Information Desian Conditions Room Name Existing Residence Time of Peak Jan 12 am Floor Area 3,003 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F 44 Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT of = = = = = = = = = = = = = = = = = = =479 =153 = = = Btu/hr 44 6,474 44 2,391 44 746 44 1,837 44 44 _3,560 1,083 44 2,335 44 60 44 546 44 4,009 44=1 064 44 766 44 1.110 44= 1,531 44 208 44 382 44=3 21R 44=287 44 287 44 919 44 1 1409 44 337 44 206 44 382 44 3931 44 746 44 268 44 746 748 44 24 44 44 153 44 4,914 44 62.859 X X X X Items shown with an asterisk (•r) denote conduction through an interior surface to another room. Page Total: 110 054 Infiltration: 1.00 x 1.064 x 3 003 x 10.00 x 0.403 / 6] x &T = 9443 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 119,496 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 16o ROOM HEATING PEAK LOADS Project Title Date a obianco Residence -Alteration 10/2/2007 Room Information Desicin Conditions Room Name Dining Addn Time of Peak Jan 12 am Floor Area 220 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value OT of Btu/hr 220.0 X x X x X X x X X x x X X X X X X X X X x x x x X X x X X X X x X X X X X x x 0.0250 X X X X X x X X X x X x X X X X X X X x x x X x X X x X X X X X X X x X X x X 44 = = = = = = = = = = = = = = = = = = = = = 242 37.5 0.0690 44 114 17.5 0.6200 44 477 40.0 0.7900 44 1,390 35.0 0.6200 44 955 130.0 0.0690 44 395 135.0 0.0690 44 410 35.0 0.6200 44 955 perimeter=43.0 0,7300 44 1381 nems snown wim an astensK f-rrf genote conduction through an interior surace to another room. Page Total: I 6,319 Infiltration: I1 1.001 x 1.064 x 220 x 10.00 x 0.403 / 60] x 0 = 692 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,011 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 17 of 23 ROOM HEATING PEAK LOADS Project Title a obianco Residence -Alteration Date 10/2/2007 oomInformation Design Conditions Room Name Master Bdrm Addn Floor Area 311 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 12 am Outdoor Dry Bulb Temperature 26OF Conduction surface Area Area X x x X x x x x x x x X x x x X X X x x X X X x X X X X X X X x x X X X X x X x U -Value X X X . X x X X x X X X X X X X x x X X X X X X X X X X X x x x x X X X x x X x x AT of = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Attic 311.0 0.0250 44 342 R-21 Wall 150.0 0.0690 44 455 R-21 Wall 213.0 0.0690 44 647 Glass Block 7.0 0.5500 44 169 30.0 0.6200 44 818 R-21 Wall 150.0 0.0690 44 455 erimeter = 55.0 0.7300 44 1,767 Items shown with an asterisk (•r) denote conduction through an interior Infiltration: 1.001 x 1.064 x chedule Air Sensible Fraction to another room. 311 x 10.00 Ceiling Height 0.403 / 6] ACH Page Total: LT DT 4 654 g7g TOTAL HOURLY HEAT LOSS FOR ROOM 5,632 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 18 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date a obianco Residence -Alteration 110/2/2007 oom Information Desi n Conditions Room Name: Existing Residence Outdoor Dry Bulb Temperature: 1120F Floor Area: 3,003 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F opaque 5urtaces Default Roof 1978 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Default Wall 1992 to Present Orientation Area x X X X X X x X X X X x U -Factor X X X X X X x X X X X X CLTD 1 N 3,003.0 0.0490 56.0 N 607.7 0.1020 23.0 E 893.2 0.1020 33.0 SE 46.0 0.1020 31.0 S 717.0 0.1020 26.0 SW 46.0 0.1020 31.0 (W) 876.0 0.1020 33.0 43.4= N 0.0 31.4 2.5 31.4 N 0.0x 27.2+ 20.0X 27.2= E 0.0x 43.4+ 27.8X 84.9= E 0.0 43.4 20.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Window Page Total Btu/hr 17 813 Orientation Shaded Area X X X x X GLF + + + + + Unshaded Area X X X X X Page GLF = = = _ = N 0.0 43.4 19.5 43.4 N 0.0x 43.4+ 48.0X 43.4= N 0.0 43.4 93.0 43.4 N 0.0x 43.4+ 28.3X 43.4= N 0.0X 43.4+ 61.0X 43.4= N 0.0 31.4 2.5 31.4 N 0.0x 27.2+ 20.0X 27.2= E 0.0x 43.4+ 27.8X 84.9= E 0.0 43.4 20.0 84. E 0.0x 43.4+ 29.0X Total Internal Gain Occu ants 4 Occupants X 230 Btuh/oCC. _ E ui ment 1 Dwelling Units X 1 600 Btuh Btu/hr Btu/hr 920 1,6001 Infiltration: 1.064 X 0.87 X 211.89 X = 6639 Air Sensible CFM ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 60106 Latent Gain Occupants Occupants X 200 Btuh/oCC. Btu/hr 800 Infiltration: 4 771 x 0.87 x 211.89 x 0.00263 = 2 304 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,104 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 19 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date a obianco Residence -Alteration 110/2/2007 oom Information Desi n Conditions Room Name: Existing Residence Outdoor Dry Bulb Temperature: 1120F Floor Area: 3,003 sf Outdoor Web Bulb Temperature: 78°F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F ue surraces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Window Page Total 1 01 Orientation x X X X X X x x x X x + + + + + + + + I + = X X X X X X X x I X1 GLF = = = = = = = I x E X 43.4 = 84.9 3,397 SE x 27.2+ x 36.5= = S 0.0 43.4 x 43.5 x S = 43.4 7.5 43.5 x S x 43.4 = 43.5 1,045 S x 43.4 x 43.5 = SW 0.0X 27.2+ x 36.5= x W = 43.4 19.5 84.9 x W x 43.4 = 84.9 595 W x 1 43.4 x 84.9 = I x x = x x= x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Window Page Total 1 01 Orientation Shaded Area X X X X X x x x X GLF + + + + + + + + I + Unshaded Area X X X X X X X x I X1 GLF = = = = = = = I Btu/hr E 0.0 43.4 40.0 84.9 3,397 SE 0.0x 27.2+ 14.0X 36.5= 510 S 0.0 43.4 7.5 43.5 327 S 0.0 43.4 7.5 43.5 327 S 0.0 43.4 24.0 43.5 1,045 S 0.0 43.4 34.0 43.5 1,480 SW 0.0X 27.2+ 14.0X 36.5= 510 W 0.0 43.4 19.5 84.9 1,656 W 0.0 43.4 7.0 84.9 595 W 0.0 1 43.4 19.5 84.9 1 656 I I Internal Gain Occu ants B4 Occupants X 230 Btuh/occ. _ E ui ment 1 Dwelling Units X 1,6001 Btuh = Page Total 11 503 Btu/hr 920 1.6001 Infiltration: 1.064 X 0.87 X 211.89 x = &619 Air Sensible CFM ERA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 60106 Latent Gain--� Occu ants 0 Occupants X I 2001 Btuh/oCC. _ Btu/hr 800 Infiltration: 4 771 x 0.87 x 211.89 x 0.00263 = 2,304 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,104 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 20 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title knnnhinnrn Racirlanra_Altarntinn Date 1 n/?/gnm oom Information Desicin Conditions Room Name: Existing Residence Outdoor Dry Bulb Temperature: 1120F Floor Area: 3,003 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 780F Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1_ Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • Window Window Window Page Total 1 01 Orientation x X X X X X x x x X X x + + + + + + + + + + + = X X X X X X X X X X Page GLF = = = = = = = = x W x 43.4 = 84.9 1,656 W x 31.4 x 64.1 = W 0.0x 31.4 x 64.1= x = 43.4 4.0 84.9 x x 43.4 = 84.9 340 x x = X x = x x = x x = x x = Total x x = x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • Window Window Window Page Total 1 01 Orientation Shaded Area X X X X X x x x X X GLF + + + + + + + + + + + Unshaded Area X X X X X X X X X X Page GLF = = = = = = = = Btu/hr W 0.0 43.4 19.5 84.9 1,656 W 0.0 31.4 19.5 64.1 1,249 W 0.0x 31.4 1.0x 64.1= 64 0.0 43.4 4.0 84.9 340 0.0 43.4 4.0 84.9 340 Total 3 sas Internal Gain Occupants B4 Occupants X 230 Btuh/occ. E _ ui ment 1 Dwelling Units x 1 600 Btuh = Btu/hr 920 1,600 Infiltration: 1.064 X 0.87 X 211.89 X = 6,619 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 60106 Latent Gain Occu ants 4 Occupants X 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4 771 x 0.87 x 211.89 x 0.00263 = 2 304 Air Latent CFM ELA pW STOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,104 EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page: 21 o23 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title 1annhiannn RtgirIt-nr t--AltPr; inn Date 1 n/2/2nn7 oom Information Desicin Conditions Room Name: Dining Addn Outdoor Dry Bulb Temperature: 1120F Floor Area: 220 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F opaque surfaces R-38 Roof Attic R-21 Wall Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X X X CLTD 1 N 220.0 0.0250 56.0 N 37.5 0.0690 23.0 S 130.0 0.0690 26.0 W 135.0 0.0690 33.0 35.0 27.2 W 0.0x 27.2+ 35.0X 51.0 • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 969 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Nage I otal Orientation Btu/hr Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area X X X X X X X X X GLF N 0.0x 27.2+ 17.5X 27.2 N 0.0 37.7 40.0 37.7 N 0.0 27.2 35.0 27.2 W 0.0x 27.2+ 35.0X 51.0 • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 969 Page Total Btu/hr 308 60 233 307 908 Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/occ. = 920 E ui ment 1 Dwelling Units X 1 600 BtUh = 1 600 Infiltration: 1.064 X 0.87 X 15.52 X 1 486 Air Sensible CFM ELA �nT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM - Latent Gain Btu/hr Occu ants 0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4 77 X 0.87 X 15.52 X 0.00263 = 169 Air Latent CFM ELA pw • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 969 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 22 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date a obianco Residence -Alteration 110/2/2007 Room Information Desicin Conditions Room Name: Master Bdrm Addn Outdoor Dry Bulb Temperature: 1120F Floor Area: 311 sf Outdoor Web Bulb Temperature: 78oF Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr 1 Wall N 311.0 X X X X x X X x x x X X 0.0250 X X X X X x x x X X X X 77.0 N 150.0 0.0690 31.0 S 213.0 0.0690 38.0 W 150.0 0.0690 55.0 0.0 32.2 30.0 41.0 1,230 800 Infiltration: 4 771 x 0.87 x 21.94 x 0.00263 = 239 Air Latent CFM ELA n w 10 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,039 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • rage I otal 599 321 558 569 2 047 Orientation Btu/hr Shaded Area X X X X X X X X X X X GLF + + + + + + + + + + + Unshaded Area X X X X X X X X X X x Page GLF = = = = = Btu/hr S 0.0 38.2 7.0 50.3 352 S 0.0 32.2 30.0 41.0 1,230 800 Infiltration: 4 771 x 0.87 x 21.94 x 0.00263 = 239 Air Latent CFM ELA n w 10 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,039 Total 1 583 Internal Gain Btu/hr _. Occupants 4 Occupants x 230 Btuh/occ. 920 E ui ment 1 Dwelling Units X 1 200 Btuh _ 1 200 Infiltration: 1.064 x 0.87 x 21.94 X = 688 Air Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6437 Latent Gain Btu/hr Occu ants Occupants X I Btuh/occ. = 800 Infiltration: 4 771 x 0.87 x 21.94 x 0.00263 = 239 Air Latent CFM ELA n w 10 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,039 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 23 of 23