Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-0664 (AR)
R.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 r Application Number: 11-00000664 Property Address: 80384 RIVIERA APN: 762-130-010- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 43340 /A`pplicant: 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: - Z7�1t5� �6LT�,E2 -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of pe y th m licensed under provisions of Chapter 9 (commencing with Section 00 ) of Division 3 of the Busi s a d Pryi as Code,'and License is in full force and effect. Dcensg la B (— License No.: 84857 ate: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License. Law for the _ following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the -alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an.owner of•property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ' (_) I,'as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: 'CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-71.53 Date: 8/01/11 Owner: LANDAU, MIKE' 80384 RIVIERA LA QUINTA, CA 92253 ( Contractor: , EDWARDS CONSTRUCTION INC, I AUG Or' 2011 j 51455 DESERT CLUB DRIVE LA QUINTA, CA 92253 CITY( F;J%10INTA (760) 777-8202 Lic. No.: 684857 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION . I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier GRANITE STATE Policy Number WC1914223 I certify that, in the performance of the work for which this permit is issued, I'shall not employ any person in any mann o a o beco ubject to the workers' compensation laws of California, and agree that, if s uld eco ski ct to the work 'compensation provisions of Section 3700 of the Lab r ode, sh' 1RR th comply wit ose provisions. ate: •- Applicant. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE; INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application'is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set f6rth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. ' I certify that I have read this application and state ta the ve in is correct. I agree to comply with all m city an co y ordinances and state laws relating uild' g o tr n, nd hereby out rize representatives of thin y� enter u on the above-mentioned for nsp cti n p rposes. ate: ignature (Applicant or Agent). Application Number . . . 11700000664 Permit . . . BUILDING PERMIT Additional desc Permit Fee . . . . 375.50 Plan Check Fee 244.08 Issue Date . . . . Valuation 43340 Expiration Date 1/28/12 Qty Unit Charge Per Extension BASE FEE 252.00 19.00 ---------------------------------------------------------------------------- 6•.5000 THOU BLDG 25,001-50,000 123.50 Permit . . . ELECT - ADD/ALT/REM Additional desc : . Permit Fee 33.80 Plan Check Fee•. 8.45 Issue Date . . . Valuation . . . . 0 Expiration Date 1/28/12 Qty Unit Charge Per Extension BASE FEE 15.00 537.00 ------------------------- .0350 ELEC --------------------------------------------------- NEW RES - 1 OR 2 FAMILY 18.80 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 1/28/12 Qty .Unit Charge .Per. Extension ------------------------------------------------------------------------------ BASE FEE 15.00 Permit . . . . . . MECHANICAL Additional desc . Permit Fee . . . . 39.50 Plan Check Fee 9.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/28/12 Qty, Unit Charge Per. Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00. 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH VENT FAN 6.50 Permit . . PLUMBING Additional desc . LQPERMIT Application Number 11-00000664 Permit . . PLUMBING - Permit Fee . . . . 43:50 Plan Check Fee 10.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/28/12 Qty. Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50, 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 -----------------------------------------------------------------------=---- Special Notes and Comments 537 SF DETACHED GUEST CASITA ADDITION PER ENGINEERED -DESIGN. -2010' CODES Other Fees . . . . . . ... . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 24.41 STRONG MOTION (SMI) - RES 4.33 Fee summary Charged Paid Credited Due Permit Fee Total 507.30 .00 .00 507.30 Plan Check Total 273.29 .00 .00 273.29 Other Fee Total 30.74 .00 .00 30.74 Grand Total 811.33 .00 .00 811.33 LQPEILIIIT Bin a qBuilding City of La Quinta ex Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application ano Tracking Sheet Permh # UILl ¢ ` Project Address: — k'-7 V L ��1� Owner's Name: A. P. Number: 76 2 3�5 ®1 C) Address: Legal Description: LC -','T- 2 ''z City, ST, Zip: Contractor: O� �� � �� Telephone: Address: - 4 C�F!5; Project Description::�, City, ST, Zip: LIN�tr � r 5;1lC-'r �t T7CKJ Telephone: ")7 g 2, City Lic. #: State Lic. # :bb S-7 , Designer:�L Address: 7 7-6 (s Z t( -9r;. City, ST, Zip:FA-( A Telephone:5 7 State Lic. #: Coastruction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Pt : J#Stories: #Units: Name of Contact Person: �� Telephone # of Contact Person: Estimated Value of Project: © 0QQ APPLICANT: DO NOT WRITE BELOW THIS LINE If It Submittal Req'd Ret'd TRACKING PERMIT FEES Plan Sets ?j Plan Check submitted (O Item Amount Structural Cales. Reviewed, ready fo eorrectio Plan Check Deposit Taus Calcs. Called Contact Person 7 I Plan Check Balance Energy Cales. Plans picked up �( Construction Flood plain plan Plans resubmitted It. Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact PersonIM 22 - 11 Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading W HOUSE:- "Review, ready for correctionstissue eveioper Impact Fee Planning Approval Called Contact Person ,I,P,P, Pub. Wks. Appr Date of permit issue School Fees " . tNJ Total Permit Fees �l �'� . �-�.�... ��-- P►-.��+�'-gid M Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 i This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS: ' CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: F Date: August 2, 2011 Owner's Name: Mike Landau Phone No. 760-777-8202 Project Address: 80-384 Riviera, LaQuinta, CA 92253 Project Description: Detached Guest Casita, Addition to Existing SFD s APN: 762-130-010 Tract #: Type of Development:Residential XX Total Square Feet of,Building Area: Certification of Applicant/Owners: The person signing.certifie a penalty of perjury and further represents that he/she isluthoze to s} Dated: August 2, 2011, Signature: Lot #'s: Commercial 537 sq. ft. the above' mat orion is b n if 6f the owner Industrial and makes this statement under SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code . Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 537 sq. ft. Amount per Sq.Ft. $ 0.00. Amount Collected $ 0.00 Building Permit Application Completed: Yes/No By: Jamie T. Brown, Asst. Supt., Business Services Note: No payment required pursuant to agreement with Sunrise, $628.00 per dwelling. Certificate issued by: Laurie Howard, Secretary HI Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective. January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. . MV:c,nrvdocs/devices/certificate of compliance form table -TO USG.doc 1/16/03 T 4 May 16, 2011 Mike &Sharon Landau 80-384 Riviera La Quinta, CA 92253 0 PGA WEST H RES]mEN'TIAL ASSOCIATION, INC. 39755 BERKEY DRIVE STE A PALM DESERT, CA 92211 PHONE (760) 776-5100 • PAX (760) 776-5111 Reference: 80-384 Riviera, La Quinta, CA Architectural Change Request — Casita with Skylight Dear Mike & Sharon Landau: The Architectural Committee met on May 12, 2011 'and reviewed'and approved your architectural plans and approved with the f6llowr9 conditions being met • All other Architectural Rules & Regulations of PGA WEST II Resideritial Association dated Revised 8/1/07 pertain. • A Maintenance Agreement will be required, one will be sent to you fur proper execution as soon as it is prepared by counsel. • Your contractor must meet with Bob Pantanella, Director of Community Services prior to commencing any work so they are aware of access, parking and other.regulations of the Association, Mr. Pantanella's phone numbers is 760-564-1032. • All trees must be planted 5 feet from the structures. Ardr/tec tura/ Ra/es afters whether or not a/1 deficienaes are noted daYnq rev/ew It rs also the' owner's fu// resnonsibi/ity tv field verify a// exislfna cnndi#ions The Committees decision with nand to project desjyn wi be Fina/ Please refer to the Am*itectura/ Rues for all required submittals: Please contact Luis Umana, 'Sunshine Landscape at 760/346-3999 and Joanne Rose, the Association Manager, prior to any irrigation modifications associated with this change. Damage to landscaping, i.e. shrubs, trees, flowers and turf is the responsibility of the contractor. The original landscaping must be brought back to its original condition when the project.is completed. Approvals given by the Architectural Committee are good for only six months from the date on the approval letter. If construction has not commenced within six months after the project _.. __a��roval_date,.a.new application mpq.be.subm.itted _.... . �f Mike.&.Sharon Landau 80-384 Riviera La Quinta, CA 92253- Reference: 2253 Reference: 80-384 Riviera,. La Quinta Application for Landscape Change Dear Mike & Sharon Landau: The Landscape Committee met on May 12, 2011 -and reviewed. and approved your landscape°application for your home at 80-384 Riviera contingent upon the following conditions being met. • Added Irrigation must be drip system with rigid pip per shrub. e, schedule '40; one dripper ' • The Association owns, and the landscape. contractor operates, a TORO irrigation system. Modifications to existing, or. installation of new irrigation equipment, shall be coordinated with. the landscape committee. Al sprinklers shall be Rainbird, 1804. or 1806 SAM body assembly. • All new plants are to be guaranteed for one .year from date. of Notice of -Completion approval by the contractor, the Association will not be responsible. for . plant replacement during this time, nor replacement of any. of the trees. No modifications to the approved plan may be made unless it is re -submitted th the Association for approval prior to installation. Homeowner will be responsible for the cost of the trimming of the Washingtonia .. Robusta once a year when the.Association trims them, you will be billed for this trimming.. There are .only 4 approved Washingtonia Robusta on the plan.. Please contact Luis Umana,, Sunshine Landscape at 760/346-3999 and Joanne Rose, the Association Manager, prior to any irrigation modifications. associated with this change. Damage to the landscaping, i.e., shrubs, trees, flowers and turf is the responsibility of. the. contractor. The original landscaping must be brought back to its original condition when the oro s.-compieted.---_ ......_ ..._..... __ - . Upon completion of your project, please complete and return The Notice of Completion of Architectural/Landscape Change. For additional information or questions, the Board has directed that you contact Joanne Rose, Association* Manager, at 760/776-5100, Ext. 320, or Cathy Clark, Assistant Manager, Ext. 318. Sincerely, . PGA WEST II Residential Association Landscape Committee cc: Sunshine Landscape Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 7/13/2011 Electronically Signed at Ca10ERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 7/13/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/13/2011 Project Address 80-384 Riviera La Quinta California Energy Climate Zane CA Climate Zone 15 Total Cond. Floor Area 517 I Addition 1 n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic 9, R-38 K � t (0509 Rad' New Wall Wood Framed 21 () F67LA UTN-W,' 1. New Slab Unheated Slab -on -Grade one 1 - New �- CTION cL 1 , FENESTRATION U. _-.-- error Orientation Area(ft) - Factor SHGC Overhang Sidefins Shades Status Skylight 8.0 0.800 0.39 none none None New Front (NE) - 24.0 0.400 --• - .:.,.0.35_.... --none::, ..-.-.n--none :- BugScreen,;...; New Front (NE) 4 25.0 0 400 :0.35 2.0 ° none Bug Screen New Left (SE) �! ` 3 0.720 0.59 2.01 i 'none Bug Screen New Rear(SlM 0.400 0!35 .10.0, none BugScreeri ti whew t'�' Right (NVV) ." 18.0 ''0.4oa--" -0.35 2.0 none Bug:Screen-. ,J New DID t HVAC SYSTEMS BY: Ot . Heating Min. Eff Cooling Min. Eff Thermostat meatus 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins New Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-07-13T14:21:32 ID: Pae 1 of 5 Reg: 211-N0034695A-000000000-0000 Registration Date/Time: 2011/07/13 17:27:46 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 7/13/2011 Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 7/13/2011 I I PERFORMANCE CERTIFICATE: Residential I (Part 2 of 5) CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration. Date 7/13/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. ttw 4 6 B ITT '6.~i^e ,.F'df} �} �yi"'J �. �q r�ai•-yk'K�j`� U-1-KR: HERS:REQUIRED VERIF.,ICATION x s, s ... 4 44 Items m this section;re ulre field testing and/or,r,-vverlficatiowby,a certified HERS Rater. Th6e1inspector,most receive a cc m Iected.CF-4R form:for<each of,the'measures'listed below for.final to be iven. The HVAC System'HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage ets'the specified criteria. Ene Pro 5.1 6 Ene Soft User Number.• 6712 RunCode: 2011-07-13714:21:32 ID: Page 2 of 5 Reg: 211-N0034695A-000000000-0000 Registration Date/Time: 2011/07/13 17:27:46 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 7/13/2011 Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 7/13/2011 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Mike Landau ❑ Multi Family ❑ Existing+ Addition/Alteration 7/13/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r ' Space Heating 6.48 5.48 1.00 Space Cooling 84.21 77.38 6.83 Fans 1 18.01 19.55 -1.54 Domestic Hot Water 43.39 42.01 1.38 Pumps 0.00 0.00 0.00 Totals 152.09 144.42 7.67 Percent Better Than Standard: 5.0% ! BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 60 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 185' 49 Fuel Available at Site: Natural Gas (SE) 315 6 Raised Floor Area: 0 (SVIO 185 40 Slab on Grade Area: 517 (NW) 315 18 rIr Average Ceiling Height./.;"' >t ... ; 10.0 _ Roof 517 8 Fenestration Average, U -Factor: 0.42 TOTAL: 121 Avera e:SHGC: 0.36 Fenestration/CFA Ratio: 23.5 REMARKS--- Y, t �' •SN`� ,. 1'2�. �,tT ?wi' W „ r �°,.Y g?`A � 9a f "11Y// '• a'l;' ray .. "'_.. a... 43' x: .x• S h .R S•...z r"h,.,.,«. "fit'.^"= - F.. s `" Y'^�:r<.. f as I � � • ri r7,P ...i$++. � ..9 i4'`v -t . STATEMENrOF COMPLIANCE This certificate ofcompliancelists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of theCalifornia Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation, Author Company Scott Design and Title 24, Inc, 7/132011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting Address 77-622 Country Club Dr. Suite O Name Robert Pitchford City/State/zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed License # Date EnergyPro 5.1 bV Ene mySoft User Number: 6712 Run Code: 2011-07-13714:21:32 ID: Page 3 of 5 Reg: 211-N0034695A-000000000-0000 Registration Date/Time: 2011/07/13 17:27:46 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 7/13/2011 Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 7/13/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/13/2011 OPAQUE SURFACE DETAILS Surface - U- Insulation Joint Appendix Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Type Area FactorPR-21 Roof 509 0.026 0 0 New 4.2.1-A9 Casita Wall 136 0.069 40 90 New 4.3.1-A6 Casita Wall 309 0.069 130 90 New 4.3.1-A6 Casita Wall 145 0.069 210 90 New 4.3.1-A6 Casita Wall 297 0.069 310 90 New 4.3.1-A6 Casita Slab 457 0.730 None 0 180 New 4.4.7-A1 Casita Slab 60 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area =`U -Factor: SHGC Azm Status Glazing Type Location/Comments 1 Skylight 8.0 0.800 NFRC 0.39 NFRC . 0 New Double Metal Tinted Skylight Casita - 2_ Window 24.0 .0.400 NFRC 0.35 NFRC 40 New Double Non Metal Tinted Casita 3 Window"" •-' 125.0 i'0.400 NFRC: 0.35 NFRC 40 New Double Non Metal Tinted Casita 41 Window' 6.3' ;0.720 NFRC' 0.59 NFRC 130 New Glass Block Casita 5 1 Window , ,w ,, 40. 01 0.400 NFRC.._; ,.:0:35 NFRC ,.... , _ 210 New _,,.,-, .Double.Non MetalTigted,, �,,�_ Casita 6 ; Win d6Wk `.>�u18.0 0.400 NFRC„„d <,0.35 NFRC ' x310 New, Double Non Metal`Tinted��+O.:, Casita if._f.+i`" .y$ A4 F��.� .3 ry, ��%�- ":b�`"` ti{m �} �,�.y .: A. a.$�."it"`"!•-0 �... �' L.^� �.-+�'=M" ��: � w , w.M .'y'�_._ ',. �a i.. �9..i � '�66 'fit ��. �:.t�• tww...�,�.� i t` +w �'FT � e k .; a'w. .. • d R�.r _.:.'JUm � i�. k.•MyY':Y 4 z� y�" JSj',4-f•rit�� ' :r fir. --0 ,77-7,f:y ;L w z•' r 5 .m.„ -.d, 4 • ' ,.±:.i. .1nw+.m ° 0 o tM .'• is _ f 3' __.t iro•+y `a. '3 ��:h tib"' n h { (1) U -Factor Type: • 1,16=A_=`Default Table from Standards, NFRC = Labeled Value , 2 SHGC Type:. '116-B'= Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd - Len H t LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 4 lBug Screen 0.76 2.5 2.51 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 8.0 10.0 0.1 10.0 10.0 6 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-07-13T14:21:32 ID: Page 4 of 5 Reg: 211-N0034695A-000000000-0000 Registration Date/Time: 2011/07/13 17:27:46 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 7/13/2011 Electronically Signed at CalCERTS.com by Robert A Pitchford (Robert A. Pitchford Design & Drafting) 7/13/2011 I CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1711312011 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existing Altered Removed Volume Year Built HVAC Casita 517 5,170 Totals 1 5171 0 01 0 HVAC SYSTEMS ._:'System Name* -.`Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC " "'F 1, Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 3 /W, HVA'C`DISTRIBUTION it, f1_1 Lr 'e, Ji ?�,� t .� i '' "'";,,.„ k :` Duct Ductst rf 'S stem Name Heatin r` ' Coohn ':Duct LocaUori„: 711 A -Value Tested? Status HVAC 'Ducted E = ` Ducted Attic, Ceiling Ins, vented 8.0 121 New A. WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated• Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas All Pipes Ins 40,000 50 0.58 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 a — System Name Pipe Len th Pipe Diameter Insul. 'Thick. _ Qty. H P Plenum 6 utside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-07-13T14:21:32 ID: Page 5 of 5 Reg: 211-N0034695A-000000000-0000 Registration Date/Time: 2011/07/13 17:27:46 HERS Provider: CalCERTS, Inc I : BUILDING ENERGY ANALYSIS REPORT I 0 PROJECT: Mr. & Mrs. Mike Landau 80-384 Riviera La Quinta, CA 92253 'Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: • Tim ScottIs . �..,.:. ,c Scott Design and Title 24;1ncIR 77-085 Michigan Driv„ CITY OF LA QUINTA Palm. Desert, Ca 9221.^ BUILDING & SAFETY DEPT: ' (760j 200-4780 APPROVED FOR CONSTRUCTION I p4m o)ZO U BY j r Job Number: RECEI'VEI) Date: JUL '14 2011 7/13/2011 BY: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-07-13T14:21:32 /D: • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type to Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/13/2011 Project Address 80-384 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 517 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 509 Radiant Barrier New Wall Wood Framed R-21 887 New Slab Unheated Slab -on -Grade None 517 Perim = 103' New FENESTRATION Orientation Area(ft) U- Exterior Factor SHGC Overhang Sidefins Shades Status Skylight 8.0 0.800 0.39 none none None New Front (NE) 24.0 0.400 0.35 none none Bug Screen New Front (NE) 25.0 0.400 0.35 2.0 none Bug Screen New Left (SE) 6.3 0.720 0.59 2.0 none Bug Screen New Rear (SW 40.0 0.400 0.35 10.0 none Bug Screen New Right (NVtq 18.0 0.400 0.35 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins New EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2011-07-13714:21:32 ID: Page 3 of 14 • E PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mf: & Mrs. Mike Landau Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/13/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Energypro 5.1 by Energ ySoft User Number: 6712 RunCode: 2011-07-13714:21:32 ID: Page 4 of 14 0 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑Addition Alone Date Mr. & Mrs. Mike Landau ❑ Multi Family ❑ Existing+ Addition/Alteration 1711312011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 6.48 5.48 1.00 Space Cooling 84.21 77.38 6.83 Fans 18.01 19.55 -1.54 Domestic Hot Water 43.39 42.01 1.38 Pumps 0.00 0.00 0.00 Totals 152.09 144.42 7.67 Percent Better Than Standard: 5.0% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 60 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 185 49 Fuel Available at Site: Natural Gas (SE) 315 6 Raised Floor Area: 0 (S 149 185 40 Slab on Grade Area: 517 (N►M 315 18 Average Ceiling Height: 10.0 Roof 517 8 Fenestration Average U -Factor: 0.42 TOTAL: 121 Average SHGC: 0.36 Fenestration/CFA Ratio: 23.5% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate andcomple Documentation Author Company Scott Design and Title 24, Inc, 7/132011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct d sign, duct sealing, verification of refrigerant charge, insulation installation quality, and bujldin aling re re installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting Address 77-622 Country Club Dr. Suite O Name Robert Pitchford City/State/zip Palm Desert Ca 92211 Phone (760) 346-2856 Signed License # Date EnemvPro 5.1 by Energ ySoft User Number.' 6712 RunCode: 2011-07-13T14:21:32 /D: Page 5 of 14 171 0 C: CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1711312011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Roof 509 0.026 R-38 0 0 New 4.2.1-A9 Casita Wall 136 0.069 R-21 40 90 New 4.3.1-A6 Casita Wall 309 0.069 R-21 130 90 New 4.3.1-A6 Casita Wall 145 0.069 R-21 210 90 New 4.3.1-A6 Casita Wall 297 0.069 R-21 310 90 New 4.3.1-A6 Casita Slab 457 0.730 None 0 180 New 4.4.7-A 1 Casita Slab 60 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Skylight 8.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted SkyLight Casita 2 Window 24.0 0.400 NFRC 0.35 NFRC 40 New Double Non Metal Tinted Casita 3 Window 25.0 0.400 NFRC 0.35 NFRC 40 New Double Non Metal Tinted Casita 4 Window 6.3 0.720 NFRC 0.59 NFRC 130 New Glass Block Casita 5 Window 40.0 0.400 NFRC 0.35 NFRC 210 New Double Non Metal Tinted Casita 6 Window 18.0 0.400 NFRC 0.35 NFRC 310 New Double Non Metal Tinted Casita (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC HqA Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len Hat Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 8.0 10.0 0.1 10.0 10.0 6 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-07-13T14:21:32 ID: Page 6 of 14 • • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. & Mrs. Mike Landau Building Type D Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1711312011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC Casita 517 5,170 Totals 517 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas All Pipes Ins 40,000 50 0.58 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 ¢ c System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 10 1 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-07-13T14:21:32 ID: Pae 7 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name r. &Mrs. Mlke Landau Date 1 7/13/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-111(a). r 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof, is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(20 Owhen specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. AwL §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and ti ht-fittin damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances .(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation havingan installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. 1 §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table - 123 -A. 150 3A: Insulation is protected from damage, including that due to sunk ht, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 1 50 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-07-13714:21:32 ID: Page 8 of 14 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date r. & Mrs. Mike Landau 7/13/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-07-13714:21:32 /D: Page 9 of 14 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date r. & Mrs. Mike Landau 7/13/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-07-13714:21:32 ID: Page 10 of 14 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name r. & Mrs. Mike Landau Date 7/13/2011 System Name HVAC Floor Area 517 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 441 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 51,000 9,851 1,123 245 10,208 Total Output Btuh 51,000 0 Output Btuh/s ft 98.6 569 502 Cooling System 0 0 Output per System 35,5001 0 01 0 0 Total Output Btuh 35,500 0 1,123 0 Total Output Tons 3.0 569 502 Total Output Btuh/s ft 68.7 Total Output s ft/Ton 174.8 10,988 11,211 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 New HVAC 27,930 2,896 51,000 Airflow cfm/s ft 2.32 51,000 Jan 1 AM Airflow cfm/Ton 405.6 Outside Air % 0.0% Total Adjusted System Output 27,930 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 2,8961 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 1,200 cfm 70 OF 70 OF 110 OF Heating Coil 109 OF i ROOM M 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 78164 OF 78 / 64 OF 57 / 55 OF Outside Air Ar 0 cfm Supply Fan Cooling Coil 57 / 56 OF ........_.....___......._..._._........_... 1,200 cfm 44.9% j -ROOM 78 / 64 OF ' 78/ 63 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-07-13714:21:32 /D: Page 11 of 14 n • ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Mike Landau Date 7/13/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 517.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr 44 = 582 44 = 282 44 = 2,692 44 = 1,883 44 = 200 44 = 3,308 = = = = = = = = = = = = = = = = = = = = = = = = Page Total 8.947 /60] X 44 = 1,261 AT R-38 Roof Attic 509.0 0.0260 Double Metal Tinted SkyLight 8.0 0.8000 R-21 Wall 886.7 0.0690 Double Non Metal Tinted 107.0 0.4000 Glass Block 6.3 0.7200 Slab -On -Grade Perim = 103.0 0.7300 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 517 x Area another room 10.00 X 0.312 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 10,208 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-07-13T14:21:32 ID: Page 13 of 14 . 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name77/13/2011 ate Mr. & Mrs. Mike Landau ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 517.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (N) 509.0 X 0.0260 X 56.0 = 741 R-21 Wall (NE) 136.0 X 0.0690 X 28.3 = 266 R-21 Wall (SE) 308.7 X 0.0690 X 31.2 = 665 R-21 Wall (SVV) 145.0 X 0.0690 X 29.3 = 293 R-21 Wall (NV O 297.0 X 0.0690 X 30.5 = 626 X X = X X = X X = X X = Page Total 1 2,591 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight 1 (N) 0.0 X 30.9 + 8.0 X 83.7 = 670 Window 2 (NE) 0.0 X 21.0 + 24.0 X 31.0 = 744 Window 3 (NE) 0.0 X 21.0 + 25.0 X 31.0 = 775 Window 4 (SE) 6.3 X 36.3 + 0.0 X 50.4 = 229 Window 5 (SIA0 40.01 X 21.0 + 0.0 X 26.4 = 840 Window 6 (NIA9 0.2 X 21.0 + 17.8 X 33.3 = 597 X + X = X + X = X + I X = Page Total 3,853 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 28.29 X 34 = 886 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,851 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,771 X 0.87 X 28.29 X 0.00276 = 323 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,123 Ene Pro 5.1 6 V Ene Soft User Number: 6712 RunCode: 2011-07-13T14:21:32 /D: Pae 14 of 14 the/ f9,.ywtiq/ bruWrew STRUCTURAL AND CIVIL ENGINEERING DENISE R. POELTLER, INC. 77.725 Enfield Lane • Unit # 130 • Palm Desert, California 92211 drpfly@aol.com 14 July 2011 Mr. Greg Butler, Plans Examiner CITY OF LA QUINTA CITY OF LA QUINTA BUILDING & SAFETY DEPT. Department of Building and Safety APPROVED 78-495 Calle Tampico <:1 La Quinta, CA 92253 FOR CONSTRUCTION -F,4 1 RE: LANDAU CASITA DATE ©1 BY Job Site Address: 80-384 Weiskopf, PGA West Subject: Truss Acceptance Letter Dear Mr. Butler: I have reviewed the total deflection, live, dead, and drag loads used for the design of the gang -nail roof trusses prepared by BMC SELECT (dated 07-07-11), and found them in substantial conformance with the structural documents prepared by my firm. Respectfully submitted, C&04C�J�' Denise R. Poeltler R.C.E. 33446 W.O. 11-139 cc: Robert A. Pitchford, Designer PHONE (760) 772-4411 0 FAX (760) 772-4409 �O QRoFESSIpyA� F W~�Qk'�`�� P. POLI F9c• Q No. 33446 p Exp. 6-30-11— CIV 2crV