BRES2016-011478-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: BRES2016-0114
Property Address:
80400 RIVIERA
APN:
762200028•
Application Description:
LENCH / REMODEL
Property Zoning:
Application Valuation:
$15,000.00
Applicant:
LENCH DESIGN STUDIO INC
PO BOX 450
LA QUINTA, CA 92253
D VOICE (760) 777-7125
FAX (760) 777-7011
COMMUNITY, DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
LICENSED CONTRACTOR'S DE RATION
I hereby affirm under penalty of perjury that I am Ii nsed and provisions of Chapter
9 {commencing with Section 7000} of Division 3 of a Busine and P ofessions Code,
and my License is in full force and effect.
License ss: B 2 Liceense No.: 594043
Contractor
OWNER -BUILDER D CLARATI
I hereby affirm under penalty of perjury that I.a exem from the Contractor's State
License Law for the following reason (Sec. 7031. , Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(') 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's
Owner:
GREG SINAIKO
Co
80400 RIVIERA
z L
LA QUINTA, CA 92253
o u
•c
ct
Contractor:LARRY
COIRJR DBA 7 C'S CO'
O48-236
VISTA DE NOPAL
LA QUINTA, CA 92253
(760)564-5811
Llc. No.: 594043
WORKER'S COMPENSATION DECLARATION
I herebyeaffiunder penalty of perjury one of the following declarations:
ve and will maintain a certificate of consent to self -insure for workers'
ompe as provided for by Section 3700 of the Labor Code, for the performance
of th which this permit is issued.
ve and will maintain workers'compensation insurance, as required by
Se i nf the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and polity number are:
Carrier:— Policy Number: _
I certify that in the performance ofthe work f is 's permit is issued, I
shall not employ any person in any manner so as to bp
ome subje tot a workers'
compensation laws of California, and agree that, if should beco ject to the
workers' compensation provisions of Section 37 of the Labor o e, I shall forthwith
comply with those provisions.
te: —9
C! Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR'CODE,
INTEREST, AND ATTORNEY'S FEES. '
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued.as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above i ma ion is correct.
I agree to comply with all city and county ordinances and state s rela ing to building
construction, and hereby authorize representatives of this cit o/entupon
a\bov�e-me tioned property for inspection purposes.
Dare: � Signature (Applicant or Ag rc
r DESCRIPTION r;
'; ACCOUNT kQTY PAID DATE"'
HOURLY PLAN CHECK - YES
101-0000-42600 3 $210.00 $210.00 6/3/16
a PAID,BY <& }b
.�
y aMETHOD t ;RECEIPT # `'Ya CHECK # CLTD BY'
LARRY COIA JR DBA 7 C'S CONSTR
CHECK_ R15967 10957 SKH
Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $210.00
DESCRIPTIONACCOUNT
$ x
g.QTY
` r : AMOUNT''
PAID ?:; -.
<PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
6/3/16
PAID-BY
r,� METHOD
.RECEIPT #
CHECK #
CLTD' BY.�
sr
LARRY COIA JR DBA 7 C'S CONSTR
CHECK
R15967.
10957
SKH
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPT
1AUNT.,N
y-
PAID DATE.
_,-
tQTY
, a„PAID
SMI - RESIDENTIAL
101-0000-20308
0
$1.95
$1.95
6/3/16
PAID'BY - g>
METHOD
$ `RECEIPT #
:,'CHECK#
CLTD BY,`-
LARRY COIA 1R DBA 7 C'S CONSTR
CHECK
R15967
10957
SKH
Total Paid for STRONG MOTION. INSTRUMENTATION SMI: $1.95 $1.95
c a. DESCRIPTION `.
F ACCOUNT ° h
QTY
AMOUNT
PAID
PAID DATE<
DOOR/WINDOW, NEW, EA ADDITION 1
101-0000-42400
0
$10.15
$10.15
6/3/16
PAIDBY, ;,
Y METHOD
`aRECEIPT #
CHECK ,
'.CLTD BY
LARRY COIA JR DBA 7 C'S CONSTR
CHECK
R15967
10957
SKH
{ DESCRIPTION
k , ” ACCOUNT
`QTY
AMOUNT
;PAID,PAID
DATE
DOOR/WINDOW, NEW, FIRST 1
101-0000-42400
0
$60.91
$60.91
6/3/16
PAID BY
w METHOD '
RECEIPT #
CHECK #
�` CLTD BY
s
LARRY COIA 1R DBA 7 C'S CONSTR
CHECK
R15967
10957
SKH
DESCRIPTION `
K: : ACCOUNT
QTY
ppp AMOUNT
PAID'
,PAID DATE
DOOR/WINDOW, NEW, FIRST 1 PC
101-0000-42600
0
$59.46
$59.46
6/3/16
6 PAID: BY.'-,*
¢ METHOD
-RECEIPT # *Rsc
€ CHECK*..:`CLTD
BYs:'
LARRY COIA JR DBA 7 C'S CONSTR
CHECK
R15967
10957
SKH
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $130.52 _ $130.52
e
I
a
Description: LENCH / REMODEL
CHRONOLOGY
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL Status: APPROVED -CONDITIONS
Applied: 4/20/2016 SKH
Approved: 6/2/2016 BHA
Parcel No: 762200028 Site Address: 80400 RIVIERA LA QUINTA,CA 92253
Subdivision: TR 28603-2
Block: Lot: 1
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $15,000.00
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0 No. Unites: 0
KAY HENSEL
Details:. REPLACE EXISTING SLIDING GLASS DOORS AND REPLACE WITH 2 -QTY 10 FT. X 15 FT SLIDING GLASS DOORS AT REAR COVERED PATIO
PER ENGINEERED PLANS. 2013 CODES. CARBON MONOXIDE ALARM(S) REQUIRED. 2013 BUILDING CODES.
°ADDITIONAL SITES .,,,,,,,. , , „
Printed: Friday, June 03, 2016 2:11:44 PM 1 of 4
SYSTEMS
CHRONOLOGY
CHRONOLOG1f:TYPE
STAFF NAME
..;- �.
ACTION DATE COMPLETION DATE"
*NOTES-', h
�.
_Tm'
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
5/2/2016
5/2/2016
STRUC RFC 5/2/2016
RECEIVED
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
5/3/2016
5/3/2016
SKIP LENCH
PLAN CHECK SENT TO
RAMSES SEVILLA
5/18/2016
5/18/2016
OUTSIDE PC
PLAN CHECK SUBMITTAL
RAMSES SEVILLA
5/18/2016
5/18/2016
RECEIVED
LEFT VOICEMAIL FOR SKIP LENCH THAT PROJECT IS
TELEPHONE CALL
BURT HANADA
6/2/2016
6/2/2016
APPROVED. REQUIRES GRANT DEED, HOA AND CONTRACTOR
INFOR PRIOR TO PERMIT ISSUANCE.
CONDITIONS
Printed: Friday, June 03, 2016 2:11:44 PM 1 of 4
SYSTEMS
-CONDITION x DATE DATE DATE
NOTES nV
CONTACT. REMARKS-'.
-ADDED SATISFIED. -
RE
TYPE'::' 0
READY TO ISSUE GRANT DEED, HOA APPROVAL AND
CHECKLIST PURTHANADA 6/2/2016: 6/2/2616 6/3/2016 COMPLETE CONTRACTOR INFO REQUIRED PRIOR TO
ISSUANCE
APPLICANT.
LENCH DESIGN STUDIO INC
PO BOX 450
LA QUINTA
CA
92253
(
SKH'
..... ... . . .... . . .... ... . . ...... ..... . '..'' .— - I 1 .11 —
FINANCIAL Wron!VIATI
0sy N- - . .... ...... .. . ... . ... .. . . . ...
i
N CITY PAID ACCOUNT� #,
b6ck ikib AMOUNT
DATE RECEIPT # CHECK`*,,METHOD
'CL TD!
'WM
BYr
HOURLY PLAN CHECK -
101-0000-42600
3
$210.00 $210.00
6/3/16
LARRY COIA JR DBA 7
'R15967 10957 CHECK
SKH
YES
C'S CONSTR
Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $210.00
BSAS SB1473 FEE
101-0000-20306
0,
$1.00
$1.00
6/3/16
R15967
30957
CHECK
LARRY COIA JR DBA 7
SKH'
C'S CONSTR
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $1.00
BSA:
SMI - RESIDENTIAL
101- 0000-20308
0-
$1.95
$1.95
6/3/16
R15967
10957,
CHECK
LARRY COIA JR DBA 7
S KH
.
C'S CONSTR
Total Paid fogy STRONG MOTION INSTRUMENTATION SMI: $1.95 $1.95
DOOR/WINDOW, NEW,
101-0000-42400
0
$10.15
$10.15
6/3/16
R15967
10957
CHECK
LARRY COIA JR DBA 7
SKH
EA ADDITION 1
C'S CONSTR
DOOR/WINDOW, NEW,LARRY
101-0000-42400
0,
$60.91
$60.91
6/3/16
R15967
10957
CHECK
COIA JR DBA 7
SKH
FIRST 1
C'S CONSTR
Printed: Friday, June 03, 2016 2:11:44 PM 2of4 CRWSYS76AS
`DESCRIPTION
77
x `ACCOUNT
QTY. '
AMOUNT
`, PARD �`
PAID DATERECEIPT#
tz
REVIEWER
'CHECK #'',
METHODS
. "PAIDBY
CLT
BY,
DOOR/WINDOW, NEW,
101-0000-42600
0
$59.46
$59.46
6/3/16
R1S967
10957
CHECK
LARRY COIA JR DBA 7
SKH
FIRST 1 PC
BURT HANADA
STRUCT CORRECTION
IST BLDG STR (2
WK)
JOHN
THOMPSON
4/20/2016
•5/4/2016
5/2/2016
REVISIONS REQUIRED
C'S CONSTR .
Total Paid for WINDOW/SLIDING GLASS
BURT
HANADA
5/18/2016
.6/2/2016
6/2/2016
$130.52
$130.52
DOC 5/2/2016
DOOR/FENESTRATION:
JOHN
THOMPSON
5/18/2016
6/2/2016
TOTALS:
$j43.41
$343.47
COMMENTS.doc
PECTIONS
PARENT PROJECTS
REVIEW TYPE.-.; .
REVIEWER
SENT DATE
1
'DUE .DATE
Attachrtiek Type CREATED
OWNER'--
DESCRIPTION
RETURNED
DATEr
STATUS
REMARKS
:..NOTES..-.
1ST BLDG NS (2 WK).
BURT
HANADA
.4/2 0/2016
5/4/2016
5/2/2016
REVISIONS REQUIRED
BURT HANADA
STRUCT CORRECTION
IST BLDG STR (2
WK)
JOHN
THOMPSON
4/20/2016
•5/4/2016
5/2/2016
REVISIONS REQUIRED
2ND BLDG NS (2
WK)
BURT
HANADA
5/18/2016
.6/2/2016
6/2/2016
APPROVED .
DOC 5/2/2016
2ND BLDG STR (2•
WK)
JOHN
THOMPSON
5/18/2016
6/2/2016
6/1/2016
READY FOR APPROVAL
COMMENTS.doc
COMMENTS.doc
Printed: Friday, lune 03, 2016 2:11:44 PM 3 of 4
SYSTEMS
Attachrtiek Type CREATED
OWNER'--
DESCRIPTION
- PATHNAME
SUBDIR
ETRAKIT ENABLED,
1ST REVIEW NS and
DOC 5/2/2016
BURT HANADA
STRUCT CORRECTION
80-400 RIVIERA.pdf
1
LIST
1ST CHECK -
1ST,CHECK -
DOC 5/2/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
COMMENTS.doc
COMMENTS.doc
Printed: Friday, lune 03, 2016 2:11:44 PM 3 of 4
SYSTEMS
Printed: Friday, June 03, 2016 2:11:44 PM 4 of 4.
J SYSTIMS
ATTACHMENTS
AttacHment Type
CREATED `.
=OWNER
'DESCRIPTION
PATHNAME
SUBDIR ETRAKIT ENABLED:,
1ST CHECK -
1ST CHECK -
DOC
5/2/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
TRANSMITTAL.pdf
TRANSMITTAL.pdf
2ND CHECK -
2ND CHECK -
DOC
6/1/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
TRANSMITTAL.pdf
TRANSMITTAL.pdf
Printed: Friday, June 03, 2016 2:11:44 PM 4 of 4.
J SYSTIMS
Bin #
City of La Quinta
Building 8£ Safety Division
78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet.
Permit #
Ili Y' I1
Project Address: 8(�� '
Owner's Name:
A. P. Number: Z �_ O 2,ff::;. - 3
Address:
Legal Description: A4
, zn- O e,
City, ST, Zip:
Contractor: I o 2►
3
Telephone:
Address:
Project Description:
City, ST, Zip:
� p`Dr�. -• AVP !�zq K) O
Telephone:
e one•
.............................................
,
LI L I1.9 �vS
�J �O
State Lie. # :
City Lie. #.:
10 �(� Q
Arch., Engr., Designer: lerl-�. ✓TS1E�+l� `.If JDl 0
W__-46,70
Address:. �� •die .'-t"'�
—%(p 70
City,, ST, Zip:
Telephone: h
one: `1�J a
.
Construction TY Occupancy:
P :
State Lie. #
ja cir
Pr type i cle orie • New Add'n Alter )Repair R Demo
Name of Contact Person: P ld
Sq. Ft.:#Stories:
t
# Units:
Telephone # of Contact Person: 760 . /07 7-
Estimated Value of Project: T S
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACIUNG
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2"d Review, ready for-Corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for correctionstissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Q.
Total Permit Fees
APR 2 ® 2016
COMMUNOF LA TY DEVELOPMENT A
I
March 11, 2016
t
Greg Sinaiko
16621 Linda Terrace
Pacific Palisades, CA 90272
A.
Mm'A..
pGA WEST
42-635 Melanie Place, Suite 103
-Palm Desert, CA 92211
Telephone: (760) 346-1161 Fax: (760) 346-9918
Reference: ' 1 80-400 Riviera, La Quinta, CA
Architectural Change Request — Windows, Remove Bar
Dear Greg Sinaiko:
The Architectural Committee for PGA WEST II Residential Association met on March 10, 2016 and,
among other items, reviewed your Architectural Application for removing windows and replacing them
pocket sliders and removal of bar area. The Committee approves of the application contingent upon the
following terms and conditions. +
• Additionally, Bob Pantanella, Director of Community Services shall meet with your contractor to
review safety issues on the property during this project prior to any work commencing. Mr.
Pantanella maybe reached' at 760-564-1032.
Revte�'bv-file Conrmluee is only for general conformance with the architectaral iuidellnes. It is the
resgonsibilitn of the ouvner to fully uadewwd and conform to the architectural Puidelin criteria
whether or not all deficiencies are noted during review It is also tlse owner's full resvgnslblllty to Held
yerifv all existing condition The Committee's decision with regard to prosect dessgn wBl a final.
Please refer to the Architectural Rules for all required submlttak
Approvals given_ by the Architectural Committee are good for only six months from the date on the
approval letter. If construction has not commenced within six months after the project approval date, a new
application must be submitted. On completion of your project, please complete and return The Notice of
Completion of Architectural Change.
In the meantime if you have any additional questions or concerns, please do not hesitate to contact Joanne
Rose, Association Manager, at 760/776-5100, Ext. 320. . 4
Sincerely, ,
PGA WEST H Residential Association
For the Architectural Committee
Joanne Rose, CCAM
Association Manager
RECEIVE®
JUN 0 3 2016
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Plan Submittal
Job Site
Building Permit Number.
Project Description: small remodel
Exempt: O
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Owners Name
Number, Stmt, or PO Box
City, State, Postal Code
Owners Phone Number
Owners E -MI Address
Project Managers
Project Managers Phone N
Project Managers E-mail A
Builder / Contrr
Number, Street or PO
City, State, Postal C
Project Square
5/111/2016
80400 Were
Greg Sinatko
80400 Were
La Quints, CA 92253
310-749-0925
Larry Cola
760-831-5212
7c5construct1onftdc. r. com
Lary Cola
48236 Vista de Nopal
La Quanta, CA 92253
approx 90 square feet
City Approval By ,&. � &.,%3rma e
Date of City Approval OS1/10/!lo
To Be Discarded:
Product
Product
Tons
Trash
0.:
Asphalt
0.(
Brick/Block
0.(
Cardboard
0.(
Commingled
0.1
Concrete
0.1
Drywall
0.1
Donated / Reuse*
0.1
'Describe Items
Not recyclable
Product
Recyclable
Masonry (broken)
Recyclable
Plaster
Recyclable
Scrap Metal
Recyclable
Tile (floor)
Recyclable
Tile (roof)
Recyclable
Wood
Recyclable
Landscape Debris
RECEIVED
JUN 0 3 2016
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Tons
Totals: Recycle Trash Projected Diversion:
0.3 0.3 62.889E
1 understand It Is the property owners responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 511% of the jobsite waste is
diverted from lendfiging. The remaining material wig be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition pro)ect. A contractor serving as nt of the owner may obtain a DMP for the owner. However, the DMP Is still
issued In the name of the property s) a r retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property r(s) a eral contractor shag be kept Informed of the diversion progress through
bi-morality (\re��}(its. H self -hauling, all abs I from the project site must be taken to an approved rocycler or transfer
�I
Owner / Devalooer / Prdect Manage / Sunefilitendant Date
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Sinaiko Residence
80-400 Riviera
La Quinta, CA .
Project Designer:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
72875 Fred Waring Drive, Suite C
Palm Desert, Ca 92260
ti 760-345-1352
CITY OF LA QUINTA
BUILDING & SAFEPT.
APPROVED
FOR ONSTRUCTION
Vk Job Number:
DATE
Date:
4/20/2016
APR 2 0 2016
CITY OF LA QUINTA
COMMUNITY DEM new
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www,.energysoft.com.
6.7
e
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
EnergyPro 6.7 by EnergySoft Job Number ID User Number: 2655
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
CF1R-PRF-01 -
Page 1 of 9
GENERAL INFORMATION
01
Building Complies with Computer Performance
01
Project Name Single Fam Detached
03
This building incorporates one or more Special Features shown below
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ftZ-yr)
03
Project Location 80-400 Riviera
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 270
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftZ) 3524
15
Number of Zones 1
16
Slab Area (ft2) 3524
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (ftZ) 0
21
Glazing Percentage (%)18.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
06
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-04-20 09:50:43
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design "
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.41
3.06
-0.65
-27.0%
Space Cooling
178.51
177.81
0.70
0.4%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
8.56
8.56
0.00
0.0%
Photovoltaic Offset
---
0.00
0.00
—
Compliance Energy Total
189.48
189.43
0.05
0.0%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-04-20 09:50:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
- .Window overhangs and/or fins
CF1 R -PRF -01
Page 2 of 9
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
- — None —
Cooling System Verifications:
--None --
HVAC Distribution System Verifications:
- — None —
Domestic Hot Water System Verifications:
- -- None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use z =Energy Design:Ratmg 3 Margin Percent Improvement
Total Energy (kTDV/f2-yr)' 229.36 '-229 31 r. 0.05 0.0%
- includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Fam Detached
3524
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Living
Conditioned
Living Zonei
3524
9
DHW Sys 1
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider:
Report Generated at: 2016-04-20 09:50:43
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
CF1R-PRF-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
Front Wall
Living
Default Wall 1978 to 1991
270
Front
300.
36
90
Existing
No
Left Wall
Living
Default Wall 1978 to 1991
0
Left
600
126.5
90
Existing
No
Rear Wall
Living
Default Wall 1978 to 1991
90
Back
600
343.406
90
Existing
No
Right Wall
Living
Default Wall 1978 to 1991
180
Right
600
128.498
90
Existing
No
Roof
Living
Default Roof 1978 to Pres
3524
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Attic Living
Attic RoofLiving
Ventilated
0
0.1
0.85
No
No
Ex9 ti
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-04-20 09:50:43
•
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
`
Project Name: Single Fam Detached
METHOD
CF1 R -PRF -01
y •
Calculation Date/Time:
09:50, Wed, Apr 20,
2016
Page 4 of 9
g,
Calculation Description: Title 24 Analysis
i
Input
-
_ •
File Name:
Sinaiko
Renovation.xml
WINDOWS
_
r ,
01 _
02
03
04- 05
06
07
08
.09
10
Name`
. - _
`Surface(Orientation-Azimuth)N
_....
Width(ft)
Multiplie
Height r"
Area
U -factor
SHGC"
Exterior Shading",
.'
'Status
Verified
Existing
-Condition y _
Window
Front Wall (Front -270)
6.0
6.0 1
36.0
0.71
0.73
Insect Screen (default)
,`
Existing .
No
Window 2
"Left WallLeft-0
( )
6.0
6.0 1
36.0
0.71
0.73 -
Insect Screen (default)
Existing,
..No
`'1 r'
Window 3
Left Wall (Left -0)
2.0
; 2.0 1
4.0
0.71
0.73
Insect Screen (default)
Existing
• No
"•
Window 4•
Left Wall (left 0)
2.0 -
4.0 1;
8.0
0.71
0.73
Insect Screen (default)
Existing
:No
r -
t °'•
Window 5
Left Wall (Left -0)
_6.0
6.036.0
`
°0.71
0.73
Insect Screen (default)
Existing
No
.
- Window 6
Left Wall (Left -0) '
5.0 _
- 5.0_ 1
25.0 =
0.71
0.73
Insect Screen (default)
Existing
No'
Window 7
Left Wall (Left -0)
2.5
7.0 1
17.5
0.71
0.73
Insect Screen (default)
Existing
No
_ Window 8 :
'Rear Wall (Back -90)
1.8
8.0 0.931
` 13.4
0.71'
-0.73
Insect Screen (default)
Existing
. No •
-
7^Window9r------
�Rear,Wall_(Back-90)
15.0- -=-10.0--.:
150.0•x•„ _0.60.._, _0.40,,, _Insect Screen default
_..,..New-•- :--�,N/A*-J n
n
[� Window 10
`Window
Rear Wall (Back -90)
15.0
10.0 1
150.0
0.60.
0.40
Insect Screen (default)
New
-
N/A J ,
11
"
Rear Wall (Back-90)
6.0 :�
5.0 1,
30.0
-0.71
0.73 '
Insect Screen (default) .
Existing'
No
Window 12 -
Right Wall (Right -180)
4.0
5:4 0.986
21.3
0.71
0:73
Insect Screen (default)
Existing
No-'
1
Window 13
Right Wall (Right -180)'
4.0
5.4 0.986
21.3
0.71
0.73
Insect Screen (default)
' Existing
No,.
'
Window 14
Right Wall (Right -180)
2.0
2.0 - 0.8
3.2
0.71
0.73
Insect Screen (default)
Existing '
No a.
Window 15 " -
Right Wall (Right -180)
2.0
5.4 V 0.991
' 10.7
' 0.71
0.73 -
Insect Screen (default)
Existing
No:-" ♦,
Window 16
Right Wall (Right -180)
' 6.08.0�
1
48.0
0.71
_0.73
Insect Screen (default)
Existing
No
Window 17
-'
Right Wall (Right -180)
'3.0
8.0 1
.24.0
0.71
0.73
Insect Screen (default)
Existing _
- No
- Registration Number:
'
Registration Date/Time:
HERS Provider:
;
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Report Version - CF1R-04072016-744
Report Generated at: 2016-04-20
09:50:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
CF1 R -PRF -01
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Lek Fin
Right Fin
Window
Depth
Dist Up
Lek
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 7
6
0.1
6
6
0
0
0
0
0
0
0 0
0"
Window 8
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 9
8
0.1
8
8
0
0
0
0
0
0
0 0
0
Window 10
8
0.1
8
8
0
0
0
0
0
0
0 0
0
Window 11
6
0.1
6
6
0
0
0
0
0
0
0 0
0
Window 12
2
0.1
2
2
0'
0
0
0
0
0
0 0
0
Window 13
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 14 -
2
0.1
2
2
0
0
0
0
0
0
0 .0
0
Window 15
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 16
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 17
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation DatelTime: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
CF1 R -PRF -01
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R -value
Winter Design
U -value
Assembly Layers
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Living
• Cavity/Frame: no insul. /2x4 Top Chrd
585
None
0.8
2x4 Top Chord of Roof Truss @ 24
Existing
No
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
• Exterior Finish: Wood
Default Wall 1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R11
0.103
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
Over Floor Joists: R-9.9 insut.
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ftZ)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Living
3524
585
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
(%)
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
CF1 R -PRF -01
Page 7 of 9
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.5298 EF
40000-Btu/hr
0
0.04
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Multi -speed
Heating System
Cooling System
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
'Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Livin Zone1
9
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3524
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
No
No
N/A
system
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance ReportVersion - CF1R-04072016-744
HERS Provider:
Report Generated at: 2016-04-20 09:50:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Name
Type
Duct Leakage
Insulation
R -value
. Supply Duct
Location
Return Duct
Location
Bypass Duct
Status
Air Distribution
System 1
Ducts located in attic
Existing (not
specified)
4.2
Attic
Attic
None
Existing
IAQ (Indoor Air Quality) FANS
01
02
CF1 R -PRF -01
Page 8 of 9
09 10
Verified Existing HERS
Condition Verification
No N/A
03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016
Calculation Description: Title 24 Analysis
Input File Name: Sinaiko Renovation.xml
CF1 R -PRF -01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan D. Hacker
Company:
Sig Date:
Insu-form, Inc.
4/20/2016
Address:
72875 Fred Waring Drive, Suite C
CEA/HERS Certification Identification (If applicable):
City/Stat P81Desert, Ca 92260
m
Phone:
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consiste h the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this ing permit application.
Responsible esi n r ame:
Responsible g r Signature:
.
Comp ny:
� 10/ r Ili.
ed: -
Da14.-
20 42
Address:
L cense:
City/State/Zip:
Pho
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43
I- .
KtJIUtN I IAL MEASURES SUMMARY
RMS -1
Project Name
Sinaiko Residence
Building Type m Single Family ❑ Addition Alone
0 Multi Family m Existing+ Addition/Alteration
Date
4/20/2016
Project Address
80-400 Riviera La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,524
Addition
0
# of Units
1
INSULATION
Construction Type—
Area
Cavit ft) Special Features
Status
Wall Wood Framed
R11 1,466.
Existing
Roof Wood Framed Attic
R 19 3,524
Existing
Slab Unheated Slab -on -Grade
- no insulation 3,524 Perim = 585'
Existing
FENESTRATION
Orientation Area fie
Total Area: 634 Glazin Percenta e: 18.0 ol.New/Altered Avera a U- Factor:
U -Fac SHGC Overhang Sidefins Exterior Shades
0.60
Status
Front (lM 36.0
0.710 0.73 2.0 none Bug Screen
Existing
Left (N) 109.0
0.710 0.73 2.0 none Bug Screen
Existing
Left (N) 17.5
0.710 0.73 6.0 none Bug Screen
Existing
Rear (E) 13.4
0.710 0.73 2.0 none Bug Screen
Existing
Rear (E) 300.0
0.600 0.40 8.0 none Bug Screen
New
Rear (E) 30.0
0.710 0.73 6.0 none Bug Screen
Existing
Right (S) 128.5
0.710 0.73 2.0 none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat
Status
2 Central Furnace
78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value
Status
Living Zone Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type
Gallons
Min. Eff Distribution
Status
Ener Pro 6.7 by Ener Soft User Number: 2655 Plinrnrlo•
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-11l(a).
§ 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§I 10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §110.8(1) when the
installation of a cool roof is specified on the CF1R.
§ 110.80- A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access s1 11 be gasketed to Rrevent air leakage.
§150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall orhave a U -factor
factor). of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
§ 150.0(d):
§150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
§150.0(g)]: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
§150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class I1
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class H vapor retarder shall be placed over the earth floor of
§ I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0 d .
§150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as 2art of a heated slab floor meets the requirements of § 110.8
§150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U_
factor of 0.58; or the wei hted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)]A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in U50.0(h)2.
§ 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.06)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance ofR-12 or greater.
§ 150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.0(j)2& All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal and replacement of the enclosed oioe and insulation
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I50.06)2A. Piping insulation for steam and hydronic heating
s stems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.06)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is.installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas,.or plastic cover. Cellular.foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)l 1:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:S 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of 2: 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of _S 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(o)lA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mand
§ 110.4(b)1: Any pool or spa heating equipment shall be
and return lines, or built-up connections for
§ 110.4(b)2:
§ 110.4(b)3:
ator Measures Summar
installed with at least 36 inches of pipe between filter and heater or dedicated suction
future solar heating.
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods
§ 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light.
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
§150.0(p):
Lighting Measures:
§ 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ 150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with theapplicable revisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§ 150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)] E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled b vacancysensors.
§ 150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
re uirements of § 150.0(k).
§ 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D. Controls and equipment are installed in accordance with manufacturer's instructions.
§150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§ 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§150.0(k)2G: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
re uirements in §150.0 2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other re uirements in 150.0(k)2.
§150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionals of a dimmer accordingto §110.9, and coin lies with all other applicable requirements in §150.0(k)2.
§150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if the are not separately switched from kitchen lighting.
§ 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be hi efficacy or controlled b vacancysensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled b vacancysensors.
§150.0(k)7- Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficac or shall be controlled b either dimmers or vacancysensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Ener Commission to comply with theapplicable requirements in 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
Controlled by one of the follnwino myth -I.-
2013 Low -Rise Residential Mandatory Measures Summa
ry
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an ovemde or bypass switch that disables the astronomical time clock, and which is
programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an FMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is Rrograrnmed to aut ma 'cally tum the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B: following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall com 1 with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall com ] with
the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable re uirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
accordin to -30.0(c)_
§ 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occu ant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B: r. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingTess and elzress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the require nents of §110.10(b) through §110.10(e).
§110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solarzone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l: buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
buildin ro'ect and have a total area no less than 15 oercent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d): A copy of the construction documents or a comparable document indicating the information from §110.10(b) through §110.10(c)
shall be Rrovided to the occupant.
§ 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Sinaiko Residence
Date
4/20/2016
System Name
Living Zone
Floor Area
3,524
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 3,623
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
53,482
3,299 1,309
58,326
Total Output Btuh 142,000
0
Output Btuh/s ft 40.3
4,535
4,144
Cooling System
0
0
Output perSystem 42,000
0
0 0
0
Total Output Btuh 84,000
0
3,299
0
Total Output Tons 7.0
4,535
4,144
Total Output Btuh/s ft 23.8
Total Output s ft/Ton 503.4
62,552
66,613
Air System
-
CFM perSystem
1,500
HVAC EQUIPMENT SELECTION
Airflow cfm
3,000
Exist
53,360 24,444
142,000
Airflow cfm/s ft
0.85
Airflow cfm/Ton 428.6
Outside Air %
0-0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
53,3601 24,4441
Aug 3 PM
142,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions I
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
69 OF
69 OF 113 OF 113 OF
Heating Coil Supply Fan
3,000 cfm 112 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF
Outside Air
0 cfm
79 / 67 OF
79 / 68 OF 63 / 62 OF 63 / 62 OF
'sr
Cooling Coil Supply Fan
3,000 cfm
64 / 62 OF
*sR
57.1 % 1'.ROOM
78 / 67 OF
i
EnergyPro 6.7 by EnergySoff User Number: 2655 RunCode: 2 01 6-04-2 0 70 9:53:20 ID: Page 17 of 17