Loading...
BRES2016-011478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRES2016-0114 Property Address: 80400 RIVIERA APN: 762200028• Application Description: LENCH / REMODEL Property Zoning: Application Valuation: $15,000.00 Applicant: LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA, CA 92253 D VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY, DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT LICENSED CONTRACTOR'S DE RATION I hereby affirm under penalty of perjury that I am Ii nsed and provisions of Chapter 9 {commencing with Section 7000} of Division 3 of a Busine and P ofessions Code, and my License is in full force and effect. License ss: B 2 Liceense No.: 594043 Contractor OWNER -BUILDER D CLARATI I hereby affirm under penalty of perjury that I.a exem from the Contractor's State License Law for the following reason (Sec. 7031. , Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (') 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Owner: GREG SINAIKO Co 80400 RIVIERA z L LA QUINTA, CA 92253 o u •c ct Contractor:LARRY COIRJR DBA 7 C'S CO' O48-236 VISTA DE NOPAL LA QUINTA, CA 92253 (760)564-5811 Llc. No.: 594043 WORKER'S COMPENSATION DECLARATION I herebyeaffiunder penalty of perjury one of the following declarations: ve and will maintain a certificate of consent to self -insure for workers' ompe as provided for by Section 3700 of the Labor Code, for the performance of th which this permit is issued. ve and will maintain workers'compensation insurance, as required by Se i nf the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier:— Policy Number: _ I certify that in the performance ofthe work f is 's permit is issued, I shall not employ any person in any manner so as to bp ome subje tot a workers' compensation laws of California, and agree that, if should beco ject to the workers' compensation provisions of Section 37 of the Labor o e, I shall forthwith comply with those provisions. te: —9 C! Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR'CODE, INTEREST, AND ATTORNEY'S FEES. ' APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued.as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above i ma ion is correct. I agree to comply with all city and county ordinances and state s rela ing to building construction, and hereby authorize representatives of this cit o/entupon a\bov�e-me tioned property for inspection purposes. Dare: � Signature (Applicant or Ag rc r DESCRIPTION r; '; ACCOUNT kQTY PAID DATE"' HOURLY PLAN CHECK - YES 101-0000-42600 3 $210.00 $210.00 6/3/16 a PAID,BY <& }b .� y aMETHOD t ;RECEIPT # `'Ya CHECK # CLTD BY' LARRY COIA JR DBA 7 C'S CONSTR CHECK_ R15967 10957 SKH Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $210.00 DESCRIPTIONACCOUNT $ x g.QTY ` r : AMOUNT'' PAID ?:; -. <PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 6/3/16 PAID-BY r,� METHOD .RECEIPT # CHECK # CLTD' BY.� sr LARRY COIA JR DBA 7 C'S CONSTR CHECK R15967. 10957 SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPT 1AUNT.,N y- PAID DATE. _,- tQTY , a„PAID SMI - RESIDENTIAL 101-0000-20308 0 $1.95 $1.95 6/3/16 PAID'BY - g> METHOD $ `RECEIPT # :,'CHECK# CLTD BY,`- LARRY COIA 1R DBA 7 C'S CONSTR CHECK R15967 10957 SKH Total Paid for STRONG MOTION. INSTRUMENTATION SMI: $1.95 $1.95 c a. DESCRIPTION `. F ACCOUNT ° h QTY AMOUNT PAID PAID DATE< DOOR/WINDOW, NEW, EA ADDITION 1 101-0000-42400 0 $10.15 $10.15 6/3/16 PAIDBY, ;, Y METHOD `aRECEIPT # CHECK , '.CLTD BY LARRY COIA JR DBA 7 C'S CONSTR CHECK R15967 10957 SKH { DESCRIPTION k , ” ACCOUNT `QTY AMOUNT ;PAID,PAID DATE DOOR/WINDOW, NEW, FIRST 1 101-0000-42400 0 $60.91 $60.91 6/3/16 PAID BY w METHOD ' RECEIPT # CHECK # �` CLTD BY s LARRY COIA 1R DBA 7 C'S CONSTR CHECK R15967 10957 SKH DESCRIPTION ` K: : ACCOUNT QTY ppp AMOUNT PAID' ,PAID DATE DOOR/WINDOW, NEW, FIRST 1 PC 101-0000-42600 0 $59.46 $59.46 6/3/16 6 PAID: BY.'-,* ¢ METHOD -RECEIPT # *Rsc € CHECK*..:­`CLTD BYs:' LARRY COIA JR DBA 7 C'S CONSTR CHECK R15967 10957 SKH Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $130.52 _ $130.52 e I a Description: LENCH / REMODEL CHRONOLOGY Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED -CONDITIONS Applied: 4/20/2016 SKH Approved: 6/2/2016 BHA Parcel No: 762200028 Site Address: 80400 RIVIERA LA QUINTA,CA 92253 Subdivision: TR 28603-2 Block: Lot: 1 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $15,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 KAY HENSEL Details:. REPLACE EXISTING SLIDING GLASS DOORS AND REPLACE WITH 2 -QTY 10 FT. X 15 FT SLIDING GLASS DOORS AT REAR COVERED PATIO PER ENGINEERED PLANS. 2013 CODES. CARBON MONOXIDE ALARM(S) REQUIRED. 2013 BUILDING CODES. °ADDITIONAL SITES .,,,,,,,. , , „ Printed: Friday, June 03, 2016 2:11:44 PM 1 of 4 SYSTEMS CHRONOLOGY CHRONOLOG1f:TYPE STAFF NAME ..;- �. ACTION DATE COMPLETION DATE" *NOTES-', h �. _Tm' PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 5/2/2016 5/2/2016 STRUC RFC 5/2/2016 RECEIVED PLAN CHECK PICKED UP STEPHANIE KHATAMI 5/3/2016 5/3/2016 SKIP LENCH PLAN CHECK SENT TO RAMSES SEVILLA 5/18/2016 5/18/2016 OUTSIDE PC PLAN CHECK SUBMITTAL RAMSES SEVILLA 5/18/2016 5/18/2016 RECEIVED LEFT VOICEMAIL FOR SKIP LENCH THAT PROJECT IS TELEPHONE CALL BURT HANADA 6/2/2016 6/2/2016 APPROVED. REQUIRES GRANT DEED, HOA AND CONTRACTOR INFOR PRIOR TO PERMIT ISSUANCE. CONDITIONS Printed: Friday, June 03, 2016 2:11:44 PM 1 of 4 SYSTEMS -CONDITION x DATE DATE DATE NOTES nV CONTACT. REMARKS-'. -ADDED SATISFIED. - RE TYPE'::' 0 READY TO ISSUE GRANT DEED, HOA APPROVAL AND CHECKLIST PURTHANADA 6/2/2016: 6/2/2616 6/3/2016 COMPLETE CONTRACTOR INFO REQUIRED PRIOR TO ISSUANCE APPLICANT. LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA CA 92253 ( SKH' ..... ... . . .... . . .... ... . . ...... ..... . '­..'' .— - I 1 .11 — FINANCIAL Wron!VIATI 0sy N- - . .... ...... .. . ... . ... .. . . . ... i N CITY PAID ACCOUNT� #, b6ck ikib AMOUNT DATE RECEIPT # CHECK`*,,METHOD 'CL TD! 'WM BYr HOURLY PLAN CHECK - 101-0000-42600 3 $210.00 $210.00 6/3/16 LARRY COIA JR DBA 7 'R15967 10957 CHECK SKH YES C'S CONSTR Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $210.00 BSAS SB1473 FEE 101-0000-20306 0, $1.00 $1.00 6/3/16 R15967 30957 CHECK LARRY COIA JR DBA 7 SKH' C'S CONSTR Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: SMI - RESIDENTIAL 101- 0000-20308 0- $1.95 $1.95 6/3/16 R15967 10957, CHECK LARRY COIA JR DBA 7 S KH . C'S CONSTR Total Paid fogy STRONG MOTION INSTRUMENTATION SMI: $1.95 $1.95 DOOR/WINDOW, NEW, 101-0000-42400 0 $10.15 $10.15 6/3/16 R15967 10957 CHECK LARRY COIA JR DBA 7 SKH EA ADDITION 1 C'S CONSTR DOOR/WINDOW, NEW,LARRY 101-0000-42400 0, $60.91 $60.91 6/3/16 R15967 10957 CHECK COIA JR DBA 7 SKH FIRST 1 C'S CONSTR Printed: Friday, June 03, 2016 2:11:44 PM 2of4 CRWSYS76AS `DESCRIPTION 77 x `ACCOUNT QTY. ' AMOUNT `, PARD �` PAID DATERECEIPT# tz REVIEWER 'CHECK #'', METHODS . "PAIDBY CLT BY, DOOR/WINDOW, NEW, 101-0000-42600 0 $59.46 $59.46 6/3/16 R1S967 10957 CHECK LARRY COIA JR DBA 7 SKH FIRST 1 PC BURT HANADA STRUCT CORRECTION IST BLDG STR (2 WK) JOHN THOMPSON 4/20/2016 •5/4/2016 5/2/2016 REVISIONS REQUIRED C'S CONSTR . Total Paid for WINDOW/SLIDING GLASS BURT HANADA 5/18/2016 .6/2/2016 6/2/2016 $130.52 $130.52 DOC 5/2/2016 DOOR/FENESTRATION: JOHN THOMPSON 5/18/2016 6/2/2016 TOTALS: $j43.41 $343.47 COMMENTS.doc PECTIONS PARENT PROJECTS REVIEW TYPE.-.; . REVIEWER SENT DATE 1 'DUE .DATE Attachrtiek Type CREATED OWNER'-- DESCRIPTION RETURNED DATEr STATUS REMARKS :..NOTES..-. 1ST BLDG NS (2 WK). BURT HANADA .4/2 0/2016 5/4/2016 5/2/2016 REVISIONS REQUIRED BURT HANADA STRUCT CORRECTION IST BLDG STR (2 WK) JOHN THOMPSON 4/20/2016 •5/4/2016 5/2/2016 REVISIONS REQUIRED 2ND BLDG NS (2 WK) BURT HANADA 5/18/2016 .6/2/2016 6/2/2016 APPROVED . DOC 5/2/2016 2ND BLDG STR (2• WK) JOHN THOMPSON 5/18/2016 6/2/2016 6/1/2016 READY FOR APPROVAL COMMENTS.doc COMMENTS.doc Printed: Friday, lune 03, 2016 2:11:44 PM 3 of 4 SYSTEMS Attachrtiek Type CREATED OWNER'-- DESCRIPTION - PATHNAME SUBDIR ETRAKIT ENABLED, 1ST REVIEW NS and DOC 5/2/2016 BURT HANADA STRUCT CORRECTION 80-400 RIVIERA.pdf 1 LIST 1ST CHECK - 1ST,CHECK - DOC 5/2/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 COMMENTS.doc COMMENTS.doc Printed: Friday, lune 03, 2016 2:11:44 PM 3 of 4 SYSTEMS Printed: Friday, June 03, 2016 2:11:44 PM 4 of 4. J SYSTIMS ATTACHMENTS AttacHment Type CREATED `. =OWNER 'DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED:, 1ST CHECK - 1ST CHECK - DOC 5/2/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf 2ND CHECK - 2ND CHECK - DOC 6/1/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf Printed: Friday, June 03, 2016 2:11:44 PM 4 of 4. J SYSTIMS Bin # City of La Quinta Building 8£ Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet. Permit # Ili Y' I1 Project Address: 8(�� ' Owner's Name: A. P. Number: Z �_ O 2,ff::;. - 3 Address: Legal Description: A4 , zn- O e, City, ST, Zip: Contractor: I o 2► 3 Telephone: Address: Project Description: City, ST, Zip: � p`Dr�. -• AVP !�zq K) O Telephone: e one• ............................................. , LI L I1.9 �vS �J �O State Lie. # : City Lie. #.: 10 �(� Q Arch., Engr., Designer: lerl-�. ✓TS1E�+l� `.If JDl 0 W__-46,70 Address:. �� •die .'-t"'� —%(p 70 City,, ST, Zip: Telephone: h one: `1�J a . Construction TY Occupancy: P : State Lie. # ja cir Pr type i cle orie • New Add'n Alter )Repair R Demo Name of Contact Person: P ld Sq. Ft.:#Stories: t # Units: Telephone # of Contact Person: 760 . /07 7- Estimated Value of Project: T S APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACIUNG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"d Review, ready for-Corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Q. Total Permit Fees APR 2 ® 2016 COMMUNOF LA TY DEVELOPMENT A I March 11, 2016 t Greg Sinaiko 16621 Linda Terrace Pacific Palisades, CA 90272 A. Mm'A.. pGA WEST 42-635 Melanie Place, Suite 103 -Palm Desert, CA 92211 Telephone: (760) 346-1161 Fax: (760) 346-9918 Reference: ' 1 80-400 Riviera, La Quinta, CA Architectural Change Request — Windows, Remove Bar Dear Greg Sinaiko: The Architectural Committee for PGA WEST II Residential Association met on March 10, 2016 and, among other items, reviewed your Architectural Application for removing windows and replacing them pocket sliders and removal of bar area. The Committee approves of the application contingent upon the following terms and conditions. + • Additionally, Bob Pantanella, Director of Community Services shall meet with your contractor to review safety issues on the property during this project prior to any work commencing. Mr. Pantanella maybe reached' at 760-564-1032. Revte�'bv-file Conrmluee is only for general conformance with the architectaral iuidellnes. It is the resgonsibilitn of the ouvner to fully uadewwd and conform to the architectural Puidelin criteria whether or not all deficiencies are noted during review It is also tlse owner's full resvgnslblllty to Held yerifv all existing condition The Committee's decision with regard to prosect dessgn wBl a final. Please refer to the Architectural Rules for all required submlttak Approvals given_ by the Architectural Committee are good for only six months from the date on the approval letter. If construction has not commenced within six months after the project approval date, a new application must be submitted. On completion of your project, please complete and return The Notice of Completion of Architectural Change. In the meantime if you have any additional questions or concerns, please do not hesitate to contact Joanne Rose, Association Manager, at 760/776-5100, Ext. 320. . 4 Sincerely, , PGA WEST H Residential Association For the Architectural Committee Joanne Rose, CCAM Association Manager RECEIVE® JUN 0 3 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Plan Submittal Job Site Building Permit Number. Project Description: small remodel Exempt: O (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Owners Name Number, Stmt, or PO Box City, State, Postal Code Owners Phone Number Owners E -MI Address Project Managers Project Managers Phone N Project Managers E-mail A Builder / Contrr Number, Street or PO City, State, Postal C Project Square 5/111/2016 80400 Were Greg Sinatko 80400 Were La Quints, CA 92253 310-749-0925 Larry Cola 760-831-5212 7c5construct1onftdc. r. com Lary Cola 48236 Vista de Nopal La Quanta, CA 92253 approx 90 square feet City Approval By ,&. � &.,%3rma e Date of City Approval OS1/10/!lo To Be Discarded: Product Product Tons Trash 0.: Asphalt 0.( Brick/Block 0.( Cardboard 0.( Commingled 0.1 Concrete 0.1 Drywall 0.1 Donated / Reuse* 0.1 'Describe Items Not recyclable Product Recyclable Masonry (broken) Recyclable Plaster Recyclable Scrap Metal Recyclable Tile (floor) Recyclable Tile (roof) Recyclable Wood Recyclable Landscape Debris RECEIVED JUN 0 3 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Tons Totals: Recycle Trash Projected Diversion: 0.3 0.3 62.889E 1 understand It Is the property owners responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 511% of the jobsite waste is diverted from lendfiging. The remaining material wig be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition pro)ect. A contractor serving as nt of the owner may obtain a DMP for the owner. However, the DMP Is still issued In the name of the property s) a r retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property r(s) a eral contractor shag be kept Informed of the diversion progress through bi-morality (\re��}(its. H self -hauling, all abs I from the project site must be taken to an approved rocycler or transfer �I Owner / Devalooer / Prdect Manage / Sunefilitendant Date BUILDING ENERGY ANALYSIS REPORT PROJECT: Sinaiko Residence 80-400 Riviera La Quinta, CA . Project Designer: Report Prepared by: Joan D. Hacker Insu-form, Inc. 72875 Fred Waring Drive, Suite C Palm Desert, Ca 92260 ti 760-345-1352 CITY OF LA QUINTA BUILDING & SAFEPT. APPROVED FOR ONSTRUCTION Vk Job Number: DATE Date: 4/20/2016 APR 2 0 2016 CITY OF LA QUINTA COMMUNITY DEM new The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www,.energysoft.com. 6.7 e I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 12 Form MF -1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 17 EnergyPro 6.7 by EnergySoft Job Number ID User Number: 2655 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml CF1R-PRF-01 - Page 1 of 9 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Single Fam Detached 03 This building incorporates one or more Special Features shown below 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ftZ-yr) 03 Project Location 80-400 Riviera Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 3524 15 Number of Zones 1 16 Slab Area (ft2) 3524 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) 0 21 Glazing Percentage (%)18.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below 06 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-04-20 09:50:43 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design " Proposed Design Compliance Margin Percent Improvement Space Heating 2.41 3.06 -0.65 -27.0% Space Cooling 178.51 177.81 0.70 0.4% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 8.56 8.56 0.00 0.0% Photovoltaic Offset --- 0.00 0.00 — Compliance Energy Total 189.48 189.43 0.05 0.0% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. - .Window overhangs and/or fins CF1 R -PRF -01 Page 2 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: - — None — Cooling System Verifications: --None -- HVAC Distribution System Verifications: - — None — Domestic Hot Water System Verifications: - -- None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use z =Energy Design:Ratmg 3 Margin Percent Improvement Total Energy (kTDV/f2-yr)' 229.36 '-229 31 r. 0.05 0.0% - includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 3524 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Living Conditioned Living Zonei 3524 9 DHW Sys 1 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml CF1R-PRF-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition Front Wall Living Default Wall 1978 to 1991 270 Front 300. 36 90 Existing No Left Wall Living Default Wall 1978 to 1991 0 Left 600 126.5 90 Existing No Rear Wall Living Default Wall 1978 to 1991 90 Back 600 343.406 90 Existing No Right Wall Living Default Wall 1978 to 1991 180 Right 600 128.498 90 Existing No Roof Living Default Roof 1978 to Pres 3524 Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic Living Attic RoofLiving Ventilated 0 0.1 0.85 No No Ex9 ti No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-04-20 09:50:43 • CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ` Project Name: Single Fam Detached METHOD CF1 R -PRF -01 y • Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Page 4 of 9 g, Calculation Description: Title 24 Analysis i Input - _ • File Name: Sinaiko Renovation.xml WINDOWS _ r , 01 _ 02 03 04- 05 06 07 08 .09 10 Name` . - _ `Surface(Orientation-Azimuth)N _.... Width(ft) Multiplie Height r" Area U -factor SHGC" Exterior Shading", .' 'Status Verified Existing -Condition y _ Window Front Wall (Front -270) 6.0 6.0 1 36.0 0.71 0.73 Insect Screen (default) ,` Existing . No Window 2 "Left WallLeft-0 ( ) 6.0 6.0 1 36.0 0.71 0.73 - Insect Screen (default) Existing, ..No `'1 r' Window 3 Left Wall (Left -0) 2.0 ; 2.0 1 4.0 0.71 0.73 Insect Screen (default) Existing • No "• Window 4• Left Wall (left 0) 2.0 - 4.0 1; 8.0 0.71 0.73 Insect Screen (default) Existing :No r - t °'• Window 5 Left Wall (Left -0) _6.0 6.036.0 ` °0.71 0.73 Insect Screen (default) Existing No . - Window 6 Left Wall (Left -0) ' 5.0 _ - 5.0_ 1 25.0 = 0.71 0.73 Insect Screen (default) Existing No' Window 7 Left Wall (Left -0) 2.5 7.0 1 17.5 0.71 0.73 Insect Screen (default) Existing No _ Window 8 : 'Rear Wall (Back -90) 1.8 8.0 0.931 ` 13.4 0.71' -0.73 Insect Screen (default) Existing . No • - 7^Window9r------ �Rear,Wall_(Back-90) 15.0- -=-10.0--.: 150.0•x•„ _0.60.._, _0.40,,, _Insect Screen default _..,..New-•- :--�,N/A*-J n n [� Window 10 `Window Rear Wall (Back -90) 15.0 10.0 1 150.0 0.60. 0.40 Insect Screen (default) New - N/A J , 11 " Rear Wall (Back-90) 6.0 :� 5.0 1, 30.0 -0.71 0.73 ' Insect Screen (default) . Existing' No Window 12 - Right Wall (Right -180) 4.0 5:4 0.986 21.3 0.71 0:73 Insect Screen (default) Existing No-' 1 Window 13 Right Wall (Right -180)' 4.0 5.4 0.986 21.3 0.71 0.73 Insect Screen (default) ' Existing No,. ' Window 14 Right Wall (Right -180) 2.0 2.0 - 0.8 3.2 0.71 0.73 Insect Screen (default) Existing ' No a. Window 15 " - Right Wall (Right -180) 2.0 5.4 V 0.991 ' 10.7 ' 0.71 0.73 - Insect Screen (default) Existing No:-" ♦, Window 16 Right Wall (Right -180) ' 6.08.0� 1 48.0 0.71 _0.73 Insect Screen (default) Existing No Window 17 -' Right Wall (Right -180) '3.0 8.0 1 .24.0 0.71 0.73 Insect Screen (default) Existing _ - No - Registration Number: ' Registration Date/Time: HERS Provider: ; CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Lek Fin Right Fin Window Depth Dist Up Lek Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 6 0.1 6 6 0 0 0 0 0 0 0 0 0" Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 10 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 11 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 12 2 0.1 2 2 0' 0 0 0 0 0 0 0 0 Window 13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 14 - 2 0.1 2 2 0 0 0 0 0 0 0 .0 0 Window 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation DatelTime: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml CF1 R -PRF -01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R -value Winter Design U -value Assembly Layers Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Living • Cavity/Frame: no insul. /2x4 Top Chrd 585 None 0.8 2x4 Top Chord of Roof Truss @ 24 Existing No • Roof Deck: Wood Siding/sheathing/decking Attic RoofLiving Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 • Exterior Finish: Wood Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R11 0.103 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Floor Joists: R-9.9 insut. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ftZ) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Living 3524 585 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml CF1 R -PRF -01 Page 7 of 9 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.5298 EF 40000-Btu/hr 0 0.04 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 'Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Livin Zone1 9 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 3524 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A system Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance ReportVersion - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Name Type Duct Leakage Insulation R -value . Supply Duct Location Return Duct Location Bypass Duct Status Air Distribution System 1 Ducts located in attic Existing (not specified) 4.2 Attic Attic None Existing IAQ (Indoor Air Quality) FANS 01 02 CF1 R -PRF -01 Page 8 of 9 09 10 Verified Existing HERS Condition Verification No N/A 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 09:50, Wed, Apr 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Sinaiko Renovation.xml CF1 R -PRF -01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan D. Hacker Company: Sig Date: Insu-form, Inc. 4/20/2016 Address: 72875 Fred Waring Drive, Suite C CEA/HERS Certification Identification (If applicable): City/Stat P81Desert, Ca 92260 m Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consiste h the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this ing permit application. Responsible esi n r ame: Responsible g r Signature: . Comp ny: � 10/ r Ili. ed: - Da14.- 20 42 Address: L cense: City/State/Zip: Pho Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-20 09:50:43 I- . KtJIUtN I IAL MEASURES SUMMARY RMS -1 Project Name Sinaiko Residence Building Type m Single Family ❑ Addition Alone 0 Multi Family m Existing+ Addition/Alteration Date 4/20/2016 Project Address 80-400 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,524 Addition 0 # of Units 1 INSULATION Construction Type— Area Cavit ft) Special Features Status Wall Wood Framed R11 1,466. Existing Roof Wood Framed Attic R 19 3,524 Existing Slab Unheated Slab -on -Grade - no insulation 3,524 Perim = 585' Existing FENESTRATION Orientation Area fie Total Area: 634 Glazin Percenta e: 18.0 ol.New/Altered Avera a U- Factor: U -Fac SHGC Overhang Sidefins Exterior Shades 0.60 Status Front (lM 36.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 109.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 17.5 0.710 0.73 6.0 none Bug Screen Existing Rear (E) 13.4 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 300.0 0.600 0.40 8.0 none Bug Screen New Rear (E) 30.0 0.710 0.73 6.0 none Bug Screen Existing Right (S) 128.5 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.7 by Ener Soft User Number: 2655 Plinrnrlo• 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-11l(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §I 10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §110.8(1) when the installation of a cool roof is specified on the CF1R. § 110.80- A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access s1 11 be gasketed to Rrevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall orhave a U -factor factor). of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- § 150.0(d): §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. §150.0(g)]: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. §150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class I1 vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class H vapor retarder shall be placed over the earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0 d . §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as 2art of a heated slab floor meets the requirements of § 110.8 §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U_ factor of 0.58; or the wei hted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)]A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in U50.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.06)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance ofR-12 or greater. § 150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. §150.0(j)2& All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal and replacement of the enclosed oioe and insulation 2013 Low -Rise Residential Mandatory Measures Summary § 150.00)2C: Pipe for cooling system lines shall be insulated as specified in § I50.06)2A. Piping insulation for steam and hydronic heating s stems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.06)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)l: space where the water heater is.installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas,.or plastic cover. Cellular.foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)l 1: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:S 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of 2: 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of _S 0.58 W/CFM as confirmed by field verification and diagnostic testing,in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. § 150.0(o)lA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mand § 110.4(b)1: Any pool or spa heating equipment shall be and return lines, or built-up connections for § 110.4(b)2: § 110.4(b)3: ator Measures Summar installed with at least 36 inches of pipe between filter and heater or dedicated suction future solar heating. Outdoor pools or spas that have a heat pump or gas heater shall have a cover. Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. §150.0(p): Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. § 150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with theapplicable revisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting per electrical box. § 150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)] E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to be controlled b vacancysensors. § 150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable re uirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D. Controls and equipment are installed in accordance with manufacturer's instructions. §150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer §150.0(k)2G: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other re uirements in §150.0 2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other re uirements in 150.0(k)2. §150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionals of a dimmer accordingto §110.9, and coin lies with all other applicable requirements in §150.0(k)2. §150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if the are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be hi efficacy or controlled b vacancysensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled b vacancysensors. §150.0(k)7- Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficac or shall be controlled b either dimmers or vacancysensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Ener Commission to comply with theapplicable requirements in 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and Controlled by one of the follnwino myth -I.- 2013 Low -Rise Residential Mandatory Measures Summa ry a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an ovemde or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an FMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is Rrograrnmed to aut ma 'cally tum the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall com 1 with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall com ] with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable re uirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined accordin to -30.0(c)_ § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occu ant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: r. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingTess and elzress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the require nents of §110.10(b) through §110.10(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solarzone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the buildin ro'ect and have a total area no less than 15 oercent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from §110.10(b) through §110.10(c) shall be Rrovided to the occupant. § 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a §110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sinaiko Residence Date 4/20/2016 System Name Living Zone Floor Area 3,524 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 3,623 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 53,482 3,299 1,309 58,326 Total Output Btuh 142,000 0 Output Btuh/s ft 40.3 4,535 4,144 Cooling System 0 0 Output perSystem 42,000 0 0 0 0 Total Output Btuh 84,000 0 3,299 0 Total Output Tons 7.0 4,535 4,144 Total Output Btuh/s ft 23.8 Total Output s ft/Ton 503.4 62,552 66,613 Air System - CFM perSystem 1,500 HVAC EQUIPMENT SELECTION Airflow cfm 3,000 Exist 53,360 24,444 142,000 Airflow cfm/s ft 0.85 Airflow cfm/Ton 428.6 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 53,3601 24,4441 Aug 3 PM 142,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 69 OF 69 OF 113 OF 113 OF Heating Coil Supply Fan 3,000 cfm 112 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 79 / 67 OF 79 / 68 OF 63 / 62 OF 63 / 62 OF 'sr Cooling Coil Supply Fan 3,000 cfm 64 / 62 OF *sR 57.1 % 1'.ROOM 78 / 67 OF i EnergyPro 6.7 by EnergySoff User Number: 2655 RunCode: 2 01 6-04-2 0 70 9:53:20 ID: Page 17 of 17