Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2016-0020
78-495 CALLE TAMPICO -LA QUINTA, CALIFORNIA 92253 c&t!t 4.4 Q91Atcv COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/7/2016 Application Number: ^BRES2016-0020 Owner: Property Address: 80425 RIVIERA RICHARD & HELYN TOMPKINS.�-q APN: 762200010 80425 RIVIERA x� Application Description: TOMPKINS RESIDENCE / CASITA ADDITION LA QUINTA, CA 92253 M Property Zoning: n A Application Valuation: $100,000.00 - O l p Applicant: Contractor: _-Z LENCH DESIGN STUDIO INC LARRY COIA JR DBA 7 C'S COmT:UCTIv PO BOX 450 48-236 VISTA DE NOPAL �a 30) rn LA QUINTA, CA 92253 LA QUINTA, CA 92253 LICENSED CONTRACTOR'S CLA TIO I hereby affirm under penalty of perjury that I a license un r provisions of Chapter 9 (commencing with Section 7000} of Division of the B sine s and Professions Code, and my License is in full force andeffect. License Class: License IN . 594043 Date: Contractor - I hereby affirm under penalty of perjury thJit l am exempt from the Contractor's State License Law for the following reason (Sec. 31.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or. repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (__J I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for safe. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If; however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code:.The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's (760)564-5811 Llc. No.: 594043 WORKER'S COMPENSATION DECLARATION I hereby ffirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' comp tion, as provided for by Section 3700 of the Labor Code, for the performance of tFi w rk for which this permit is issued. I ve and will maintain workers' compensation insurance, as required by Se idn 00 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a o ome subject to the workers' compensation laws of California, and agree th , if I sh uld come subject to the workers' compensation provisions of Section 700 of a or Code, I shall forthwith comply with those provisi ns. Da l —1 — Applicant: WARNING: FAILURE TO SECURE WORKERS'tCOMP;ISATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this'permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state.that the abo M ormatio ' correct. I agree to comply with all city and county ordinances and st a laws relati g o building construction, and hereby authorize representatives of this ity to en er u o the above-mentioned property for inspection purposes. a�� r D�� `� Signature (Applicant or Agent►: DESCRIPTION. FINANCIAL •• • -: ACCOUNT CITY AMOUNT PAID- PAID DATE:: ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $62.36 4/5/16 PAID; BY >: METHOD ;RECEIPT #, CHECK.# CLTD BY ' 7C'S CONSTRUCTION CHECK R14534 10845 SKH DESCRIPTION ,. ; ;:. ACCOUNT QTY f :AMOUNT' PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40. $17.40 4/5/16 y PAID. BY METHOD ` RECEIPT # . CHECK# CLTD BY . 7C'S CONSTRUCTION CHECK R14534 10845 SKH DESCRIPTION : b :' ACCOUNT ' : = QTY =` .;,AMOUNT... PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 4/5/16 PAID BY - ° METHOD RECEIPT # CHECK #. CLTD BY 7C'S CONSTRUCTION CHECK R14534 10845 SKH- DESCRIPTION ACCOUNT ,'. QTY AMOUNT.. PAID PAID DATE'' ADDITION, FIRST 100 SF PC 101-0000-42600. 0 $171.14 $171.14 4/5/16 PAID BY ;,:METHOD RECEIPT # CHECK #. ;,CLTD BY 7C'S CONSTRUCTION CHECK R14534 10845 SKH Total Paid for ADDITION: $371.73 $371.73 DESCRIPTION' ACCOUNT -_. QTY `AMOUNT ; PAID PAID DATE, BSAS SB1473 FEE 101-0000-20306 0 $4.00 $4.00 4/5/16 Day -'w METHOD .RECEIPT # CHECK # 'CLTD BY. 7C'S CONSTRUCTION CHECK R14534 10845 SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $4.00 $4.00 DESCRIPTION -, ACCOUNT. QTY :`AMOUNT .. PAID ,.. PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 4/5/16 PAID BY METHOD , : > RECEIPT # CHECK .# < ' CLTD BY '. 7C'S CONSTRUCTION CHECK R34534 .10845 SKH DESCRIPTION s ' • ,ACCOUNT .. #QTY AMOUNT ` PAID . ' PAID DATE' RESIDENTIAL, FIRST 1;000SF, PC 101-0000-42600 0 $47.86 $47.86 4/5/16 "PAID BY METHOD RECEIPT #. CHECK # CLTD BY 7C'S CONSTRUCTION CHECK R14534 10845 SKH Total Paid for.ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 .` DESCRIPTION: ACCOUNT ',`; AQTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09. 4/5/16 PAID.BY METHOD :"RECEIPT #. ,: CHECK # CLTD BY 7C'S CONSTRUCTION CHECK R14534 10845 SKH DESCRIPTION =' ACCOUNT ,'; QTY '`:."AMOUNT PAID PAID'DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $4.83 4/5/16 PAID BY -.; METHOD RECEIPT 4f':1. CHECK :# CLTD BY -' 7C'S CONSTRUCTION CHECK R14534 10845 SKH DESCRIPTION ,-:- - ACCOUNT QTY ; , MOUNT,:-.' %'` PAID PAID DATE .VENT FAN ; 101 0000-42402.. 0 . - $12.09 $12.09 4/5/16` �: �` dT:,' : `y'4-Xp:'<T. 'e L'. aPAID BY� ..Xdi 'lame`: Siv"�v„v: @N L "A II � ., °d'e£»3i s A<F� �` .,.` �•4 yMETHODs 0,...:3� � +""i. �i'"sr G `�:rY.�S•-�'�: "h ...:.5. �i a2•C�pY •'z;'.n�?`.C.. ��YiJ�: �'a ��'`.� .:�Y t ,.RECEIPTS#mak .- .'m,.: .GLH.. "Je'fl�IIe.).A 4?...:L.x mo�w" I*�` � �a�^#ti::t:e3W t�77 �`.t-sT•`% A�f q CHECK #i rtf .i45F. ti `xe •$" 'I: n...E,Dfd... g'"e =iE'". ' CLTU BY .i.i�.e .f«'z.e3..:.... _( ,_w.& •-7C'SCONSTRUCTION �• - �. - .',CHECK '` R14534' - - 10845 - SKH - .g r'Lv, "�°yti8 .! ^; -..n. '., < `,. _, a'.,'."IXv'5 ;DESCRIPTION amu4 . a, -?`-'a^.=:4s>a: 3°'�a}"` F 37 .1 ACCOUNT S '+e`-,.fir-`;€E1.-"� QTY ,�iT"": AMOUNTS x PAID L'...s.-#. PAID DATE VENT FAN PC 101-000042600 0 - $4.83. $4:83 4/5/16 :2T�fiss, h"k, %.. T.ag.�r�.;, •y '`k``"T'"k, cam`...Y.+°`.g`'4>., -8 °f: '.. x"aAr4"^eu:3++T `� .. ip� PAID BYE � �a� a t- -jy. .e'v :" meq: 'a`:l..S2�°`�` •�(rT'F^� Y::"G .. `�' t f :yi "ME {�'t'^.-a '- *4.%ap ? � � ETHOD : w4w 'E' 9..<.s-.v-'�axi',1::7:' ,y- Y:�*d4�, 2� kY^''.. -t. e&.. R�ECEEIP�T # ,,§`+ uw" Ss .{.._r"fp �,Y": al . CHECK # s� •S+C ''?eC�Ti^2' FArt` ,}F. ' CLTD BY, 7C'S.CONSTRUCT, ION ,, ' CHECK R14534 10845 SKH Total Paid for MECHANICAL. : " "$33.84 $33.84 t@1T ����.:3�;::: G2Y'.•a'.4�5#.'Y.;y Yr". �'�v 6 �c.,. � � k DESCRIPTION, ._�::���. :�w`::.aY.�ait?.-:a<';a.�:w. xk�--•s:..�.`"x.t;as .,:. .. ::: �xia .-.�:5 NOW 4 4x{?' 3 �i,:>'�2�,#Eng"'$ keN . , F 6 ..:£%t.?.15i s �A000UNT ,� ` a'&Ft.":t 9 ��Xst�s:t=,x>Ism"3e.°�,;.:e°#,r%SFf:•.;;:.--. �°� n. QTY 4.'kaua��,:.:?: 2-: � 33 ��a `�' .5 R ..-h:�' �i � `z AMOUNT ~ .::.� >?"e::Ss: � � '.:8 4a 4-�'v..l.E. 3'::X�", - k�'�r �P�A. ID. � j �a4.a xPAIUxUATE FIXTURE/TRAP' 101-0000-42401 0 $,48.36 ' $48.36 4/5/16 ana`�,r'•ss;.i.=` :.. +$ .:t•4`''3` .o -g`, PAID°BY r4 tMETHOD-�&4 ....�•ins?i'§ti:,;: "`S "- -.. Mir--E a n> own t5 ,�'�=1 .0 � `tY.. <',•s ,. :#:R".- Fd - y E R ECECPT_ L : -.. i'�t8 ;;t.444N.z "€ 4..t'. . , r: s�.4t tisk' ::.'s" # 7C'S CONSTRUCTION -CHECK R14534 10845 SKH s,..'FDESCRIP...TION.. .,�. ACCOUNT' ��I„��-asYtm'-.�."-ar,. t.:h:�'''.�`��� '� TY ,. ::t �:s.,8°�+�=«r', id#Le.b,-`� ,w.,, 660, -AMOUNT7`.�P„.AID°�q.PAIDDATEr` �W.w •..raAvk:� �,:a;4•.:i gsr 3 a-?£�GrY:,:Z{{u 1.,� R %.n,.,:ia:aYlv'w7:`;'. : . FIXTURE/TRAP PC • • ' 101-000042600 . ` " ' 0 .: ' . - $48.36 .:.. .. $48.36 4/5/16 . :$AIDpBY ..,i lu`.S!:�41F.`4's 5 . .: ,'y1� W METHOD ..� i,'.�-`FSSY«: ,n°m°ait'� ..t.a'A <E ``,.'fn.cJ.�M RECEIPTS# E._„Yi. i _:x+':. 4C:. CHECK #�a •CLTD :t'„vf•'vv gni„k'�:V...iY$4 BY :a i'; ... _.l n..¢.i Y:i"m, i :7C'S.CONSTRUCTION - .CHECK .::'1114534 10845 SKH . ; r. .0_ DESCRIPTION f 'aE., "F°...:' -s ` MINN.` ' .�cx"...' T W 5g: it,.s x•� €.:; ACCOUNTgQ .rra -.:,:x:2#�5t Rff,'i'�:,rs :#P.>-:.., :^ .<¢�: c# AMOUNT,:.: yl za€ '?''i :';5 z19. z.C%Lsm .�.' .<i' ',z^. PAID-rP.AID{DATE � 7sa :. +.^`dam. ' .., .�.'..i ;€ WATER SYSTEM INST/ALT/REP : 101-0000-42401' r 0,$12' 09• $12.09 4/5/16 ^��ad 'sr,.`..;, •�»e-v,; 're ."A t4Y�`Wa ; "-"�`-� 4 PAID -:BY .n A ; , .: `.p �t��..'+TI kT':���in °P`� „ _, .-.;,'tta7w,T�"�i s"'R�1�4�-H'�`.8. �5.•d?� ; d METHOD NMI` pow � F3- :`&fU:-'1 � E REMOVE ;:� 1. -bis".iL�,''"�i+.iy ' ��`��..'t?k r, ��,;ra>t -m r T L�' '�u �z RECEIPT # kS :'; N;.::K.i.£hikt�L°; :a E1 t.: LYF fir: CHECK # E �'.R �4Y".��e4�-:x. .;e.; > . will b BYE 7C'S CONSTRUCTION .,. CHECK' ' . 1114534 .' 30845 .'-SKH • ' �n= DESCRIPT10Nr �& Ey�A000UNT� e QTY,��AMOUNT�y ". %: }.:A :PAID ; z ,45^� PAID DATE: WATER SYSTEM INST/ALT/REP!PC 101-0000-42600 :, - 0' -. $12.09 $12:09 4/5/16 m ". t i 4 ��r :.�i..:R4'i' ^4' �¢¢'. r �5, s,w X e 1 �3:. {N PAID BY x M M 3 a ..4i� j� � 7 METHOD �� ,� � s I:, -: .,. v110 � � RECEIPT # �< <�� �_ .:._CHECK #.r< .�s"`�: � CLTD BY n '. -,- 7C'S.CONSTRUCTION" . , CHECK 1114534 10845. SKH '.. Total'Paid for PLUMBING FEES:': `$120.90, .;$120.90 my; %:a` .. �id''4".a_"-ir DESCRIPTION as... a:..Esg x„g:t'a��^i'$`, "_K�AC000NT :+ ��5_:.. a�., wsk,-g' =PLAID cit PAID DATE SMI -RESIDENTIAL ' 101-0000=20308 ' 0 13.00 '.$13:00 4/5/16 v-� _Pi41UtBY `j45Yx'ziwsir...'vti46-h" S : METHOD '� ��.::. s,n,"3P� G ra •.'mow-yxy;.xf'R ��RECEIPT#qp .ux'e�,^.�a�?@.5 . " >- �. `HECK#3L5,CLTD BY X'S CONSTRUCTION .:' CHECK R14534: 10845• SKH Total"Paid for STRONG -MOTION INSTRUMENTATION•SMI. $13.00 , $13.00 o Description: TOMPKINS RESIDENCE / CASITA ADDITION Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED -CONDITIONS Applied: 1/29/2016 MFA Approved: 3/30/2016110 Parcel No: 762200010 Site Address: 80425 RIVIERA LA QUINTA,CA 92253 Subdivision: 28118 Block: Lot: 29 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $100,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 560 S. FT. ADDITION TO EXISTING DETACHED CASITA, PER 2013 CRC CODES. CONVENTIONAL LIGHT FRAM CONSTRUCTION ADDITIONAL SITES I.�Applied to Approved Printed: Thursday, April 07, 2016 1:59:05 PM 1 of 4. 1 . SYS7FnAS CHRONOLOGY "CHRONOLOGY TYPE.", 7STAFF NAME _ ACTION_ DATE T COMPLETION DATEr ' - NOTES PLAN CHECK PICKED UP STEPHANIE KHATAMI 2/16/2016 2/16/2016 SLIP LENCH PLAN CHECK SUBMITTAL MARY FASANO 1/29/2016 1/29/2016 RECEIVED TELEPHONE CALL JIM JOHNSON 2/11/2016 2/11/2016 CALLED SKIP TO INFORM HIM THE PLANS ARE READY FOR CORRECTIONS. 'TELEPHONE CALL JIM JOHNSON 3/30/2016 3/30/2016 CALLED SKIP TO INFORM HIM THE PLANS ARE READY TO ISSUE CONDITIONS CONDITIONDATE ;, DATE DATE : - . CONTACT" ' _ - STATUS REMARKS NOTES TYPE ADDED REQUIRED . SATISFIED READY TO ISSUE JIM JOHNSON 3/30/2016 3/30/2016 4/7/2016 COMPLETE CHECKLIST Printed: Thursday, April 07, 2016 1:59:05 PM 1 of 4. 1 . SYS7FnAS FINANCIAL • NAME TYPE - _ . NAME - ADDRES51: CONTACTS CITY ;STATE -ZIP- PHONE FAX EMAIL• e ' APPLICANT LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA CA 92253 - 'PAID DATE CONTRACTOR LARRY COIA JR DBA 7 C'S CONSTRUCTION & M 48-236 VISTA DE NOPAL LA QUINTA CA 92253 OWNER RICHARD & HELYN TOMPKINS 80425 RIVIERA LA QUINTA CA 92253 FINANCIAL • •• .. '.w ... C...s f.�'.. ' s DESCRIPTION .. st Y .ice -. ... •;gip ACCOUNT y5 e._ .. w.. e.. .. AMOUNT �... �,.-� .PAID - 'PAID DATE w .S RECEIPT.#, f^`.'. $ CHECK 4.', .p .... 't' , METHOD }. 9' '.k'.R. m PAID BY ADDITION, EA 101-0000-42400 0 $62:36 $62.36 4/5/16 R14534 . 10845 CHECK 7C'S CONSTRUCTION SKH ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 0 $17.40 $17.40 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION 'SKH ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH ADDITION, FIRST 100 SF 101-0000.42600 0 $171.14 $171.14 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH PC Total Paid.for ADDITION: $371.73 $371.73 BSAS SB1473 FEE 101-0000-20306 0 $4.00 $4.00 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH Total Paid for BUILDING STANDARDS ADMINISTRATION $4.00 $4.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH 1,0005E RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 APPLIANCE 101-0000-42402 0 $12.09 $12.09 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH REPAIR/ALTERATION APPLIANCE 101-0000-42600 0 $4.83 $4.83 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH REPAIR/ALTERATION PC VENT FAN 101-0000-42402 0 $12.09 $12.09 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH Printed:. Thursday, April 07, 2016 1:59:05 PM 2 of 4 SYSTEMS Printed: Thursday, April 07,20161:59:OSRN 3of4 DESCRIPTIO QTY A AID 0AID BY VENT FAN PC 101-0000-42600 0 $4.83 $4.83 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH Total Paid for. MECHANICAU. �33.84 $33.94 FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $48.36 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH WATER SYSTEM 101-0000-42401 0. $12.09 $12.09 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH WATER SYSTEM 101-0000-42600 $12.09 $12.09 4/5/16 R14534 10845 CHECK 7C'S CONSTRUCTION SKH INST/ALT/REP PC Total Paid for PLUMBING FEES: $120.90 $120.90 —7 101-0000-2030—T 07 $13.00 $13.00 4/S/16 R14534 10845 CHECK 7C'S.CONSTRUCTION 'SKH Total Paid for STRONG MOTION INSTRUMENTATION SMI: $13.00 $13.00 Printed: Thursday, April 07,20161:59:OSRN 3of4 Printed:. Thursday, April 07, 20161:59:05 PM 4 of 4 SYSTEAAS .AttachmentType CREATED OWNER DESCRIPTION PATHNAM'E SUBDIR ETRAKITENABLED,.4 �.,:.:....M , DOC 2/11/2016 JIM JOHNSON SCHOOL FEES BRES2016- SCHOOL FEES BRES2016- 0 0020.pdf . 0020.pdf DOC 3/30/2016 JIM JOHNSON SCHOOL FEES BRES2016- SCHOOL FEES BRES2016- 0 1120.pdf 1120.pdf DOC 3/30/2016 STEPHANIE KHATAMI HOA LETTER 3-28-16.pdf HOA LETTER 3-28-16.pdf 0 2ND SUBMITTAL 2ND SUBMITTAL DOC .3/30/2016 STEPHANIE KHATAMI CORRECTION LIST AND' CORRECTION LIST AND 0 COMMENTS 3-28-16.pdf COMMENTS 3-28-16.pdf CERTIFICATION OF CERTIFICATION OF DOC 4/6/2016 STEPHANIE KHATAMI COMPLIANCE —SCHOOL COMPLIANCE - SCHOOL 0 FEE RECEIPT 4-S-16 FEE RECEIPT 4-5-16 80425 RIVIERA 80425 RIVIERA.pdf• Printed:. Thursday, April 07, 20161:59:05 PM 4 of 4 SYSTEAAS Bin # .2— Permit # Project Address: City of La Quinta Building &r Safety Division 78-495 Calfe Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Owner's Name: �(}/�jZ.d� �ICLYhI Tt�rt�PKt A. P. Number: � (B 2 - Z- avCt Address: 8 Q I E SA Legal Description z'j Ze, Zg Yu City, ST, Zip: l A V t � ( C7Z2.� 3 Contractor: Z'C��J Zfij(1 g Telephone: Address: Project Description: Ar -p1 -7i ok..3 To E.Zc is � � •n1 City, ST, Zip:���� Telephone; hone - State Lic. # : City Lie. #; Arch., Engr., Designer: ka r Address: ©• F_7ir>,K 4 -GU City.,ST,Zip: LO-M -� �• Telephone: D �7 f Con struction Type: Occupancy: : State Lic. # Project hPa circle ne • New Add'nAlter Repair Demo Name of Contact Person: Sq. Ft.: —05(,r # Stories: 1 #Units: / Telephone # of Contact Person: (ap_S Estimated Value of Project: �8� e�e7 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Ctieck Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval. Plans resubmitted Grading IN HOUSE:- 'r0. Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: LT ins/ PGA West Development Date: April 5, 2016 Owner's Name: Phone No. Project Address: 80-425 Riviera St., La Quinta, CA 92253 Project Description: Addition to Casita APN: 762-200-010 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 560 Sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is thou ed to sign on behalf of the owner/developer. Dated: L1 — S- 1 L Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THEA E PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 560 EXEMPT $0.00 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Note: Specific Plan 83-002 (PGA West) Sunrise Agreement 1986 states that all residential untis within this area are to be charged a fee of $628.00 for each unit constructed regardless of the square footage. This certifeate is exempt because it ii for an addition only and theper unit fee was previoulsy_paid! Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia C. Torres, Facilities Analyst Signature: Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. \,R/:c/mydoes/devlees/ecrlilieale ofcompliance roim updated 3-2007 11/2010 �f � g T January 18, 2016 PGANMST Mr. & Mrs. Richard Tompkins 80-425 Riviera La Quinta, CA 92253 Reference: 80-425 Riviera, La Quinta, CA 92253 Architectural Change Request - Room Addition to Casita adding another bedroom and bath and living room area Dear Mr. & Mrs. Tompkins: The Architectural Committee met on January 14, 2016 and reviewed and approved your architectural plans with the following conditions being met. • The following forms must be submitted, Contractor Compliance Form & Construction Regulation Form for approval by the Association when you have selected your Contractor, and prior to any work commencing. • A Covenant and Maintenance Agreement will be required, one will be sent to you for proper execution as soon as it is prepared by counsel. • Your contractor must meet with Bob Pantanella, Director of Community Services prior to any work commencing on this project, Mr. Pantanella's phone number is 760-564-1032. • All other PGA WEST II Residential Association Architectural Rules & Regulations dated 5/20/2013 pertain to this project. Review by the Committee is on/v for genera/ conformance with the Architectural Ru/es It is the resvonsibi/iiy of the owner to fu//v understand and conform to the Architectural Ru/es criteria whether or not a// deficiencies are noted during review. It is also the owner's full resaonsibi/ity to field verify a// exigt conditions The Committee's decision with regard to proiect design will be final, Please refer to the Architectural Ru/es for a// required submittals. Please contact Luis Umana, Sunshine Landscape at 760/346-3999 and Joanne Rose, Association Manager at 760/346-1161 ext#147 prior to any irrigation modifications associated with this change. Damage to the landscaping, i.e. shrubs, trees, flowers and turf is the responsibility of the contractor. The original landscaping must be brought back to its original condition when the project is completed. Approvals given by the Architectural Committee are good for only six months from the date on the approval letter. If construction has not commenced within six months after the project approval date, a new' application must be submitted. Page II, Tompkins, January 18, 2016 Architectural Approval Room Addition to Casita Upon completion of your project,. please complete and return the Notice of Completion of Architectural Change along with City of LaQuinta Permits signed off by the City as approved final. For additional information or questions, the Board has directed that you contact Joanne Rose, CCAM, Association Manager, at 760/346-1161 or direct at 760/610-7750. Sincerely, PGA WEST II Residential Association Joanne Rose, CCAM Association Manager for Architectural Committee Cc: Peters & Freedman Bob Pantanella Y Building Permit Number. Project Description: addition Exempt: O (Materials may contain hazardous wastes and are not submit to recycling provislons) Construction Debris Management Plan Plan Submittal Datel 4/5/2016 ! Job 8Ne r ( owns t Number. Street, or Chy, State, Pon Owners Phone Owners E -Mail i + Project Manage Project Managers Phone i Project Managers E -mall BuNderI C Number, Street of CRY, State, Pot Project Square 80425 Riviera Rich Tompkins 80425 Riviera La Ouinta, CA 92253 760.5642235 Ittomo®aol.com Larry Cola 760.831-5212 7c econstnidion@dc.rr.00m Larry Cola 760-831-5212 7caconstructton0dc.mcom 560 square feet APR 0 7 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT City Approval Date of City Approval 0410 /o//% To Be Discarded: Product Trash Asphalt Brick/Black Cardboard Commingled Concrete Drywall Donated / Reuse* 'Describe Items Tons 2.50 Not recyclable Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Totals: Recycle Trash Projected Diversion: 3.5 2.5 1 68,330A Recyclablal 1 understand it Is the property owners responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator= Uveae hauls occur. l hereby cerlik that completion, Implementedon and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the Jobsite waste Is diverted from landfilling. The remaining material will be recycled or roused. I will divert, for recycling or reuse, remaining materials generated from the first day of the project through the completion of the project In accordance with this plan. This DMP Is Issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP Is still Issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bknonthly reports. If seiFhauling, all refuse material from this project site must be taken to an approved recyder or transfer ar / Developer / Project Man / Superinte rnt Date BUILDING ENERGY ANALYSIS REPORT PROJECT: Tompkins Residence 80-425 Riviera La Quinta, CA Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT, I APPROVED Report Prepared by: FOR CONSTR CTION Joan D. Hacker YsY,. Insu-form, Inc. 72875 Fred Waring Drive, Suite C Palm Desert, Ca 92260 760-345-1352 Job Number: RECEIVED JAN 2 9 2016 . CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 1/23/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. EnergyPro 6.7 by Ener Soft User Number: 2655 ID: I �sr A BUILDING ENERGY ANALYSIS REPORT PROJECT: Tompkins Residence 80-425 Riviera La Quinta, CA Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT, I APPROVED Report Prepared by: FOR CONSTR CTION Joan D. Hacker YsY,. Insu-form, Inc. 72875 Fred Waring Drive, Suite C Palm Desert, Ca 92260 760-345-1352 Job Number: RECEIVED JAN 2 9 2016 . CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 1/23/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. EnergyPro 6.7 by Ener Soft User Number: 2655 ID: I �sr CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion.xml CF1 R -PRF -01 Page 1 of 9 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Residential 03 This building incorporates one or more Special Features shown below 02 Calculation Description Title 24 Analysis 08 j Energy Osel(kTDV/ft2-yr) 03 Project Location 80-425 Riviera Compliance Margin Percent Improvement 04 City La Quinta OS Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ1509 C) IA' 6tilation Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 857 15 Number of Zones 2 16 Slab Area (ft2) 857 17 Number of Stories 1 18 Addition Cond. Floor Area 560 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 560 21 Glazing Percentage (%) 28.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification . 03 This building incorporates one or more Special Features shown below 06 �C 000 Z m� -� 7-1 �> -ation Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2016-01-23 16:47:26 ENERGY USE SUMMARY " ---04 05 06 07 08 j Energy Osel(kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement -n Space Heating 25.51 21.43 4.08 16.0% SpacelCooling 456.19 428.62 27.57 6.0% C) IA' 6tilation 0.00 0.00 0.00 0.0% e WaterlHeating 23.43 23.43 0.00 0.0% A G� GBhoi vo oltaic Offset -- -68.93 68.93 -- —C Complia ce Energy Total C: 505.13 404.55 100.58 19.9% �C 000 Z m� -� 7-1 �> -ation Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • PV System: 2.0 kW • Cathedral Ceiling • Window overhangs and/or fins CF1 R -PRF -01 Page 2 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: — None -- Cooling System Verifications: • — None -- HVAC Distribution System Verifications: • -- None — Domestic Hot Water System Verifications: • —None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use t_' Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)' 577.17 '= ,* 476 59 100.58 17.4% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION In, n0�01- I 02 03 04 05 06 07 �7 � _ CProjec Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 7 ResFdZ�ritial7 857 1 2 2 0 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion.xml CFI R -PRF -01 Page 3 of 9 ZONE INFORMATION 02 . 03 04 05 06 07 08 01 02 03 12 13 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg, Ceiling Height Water Heating System 1 Water Heating System 2 Casita Conditioned Casita1 Area Skylight 297 Roof 9 DHW Sys 1 Roof g Casita 2 Conditioned Casital Typen 560 Area (ft2) 9 DHW Sys 1 Tilt(deg) ce Emittance OPAQUE SURFACES Status Condifion m 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Window & Door Orientation Gross Area (ft2) Area (ft2) Tilt (deg) Status Verified Existing Condition Front Wall Casita Default Wall 1978 to 1991 270 Front 500 72 90 Existing No Left Wall Casita Default Wall 1978 to 1991 0 Left 800 90 Existing No Baric Wall Casita Default Wall 1978 to 1991 90 Back 600 90 Existing No Right Wall Casita Default Wall 1978 to 1991 180 Right 800 59.997 90 Existing No Roof 2 Casita Default Roof 1978 to Pres 297 Existing No Front Wall 2 Casita 2 R=19 Wall 270 Front 500 48 90 New N/A Left Wall 2 Casita 2 R-19 Wall 0 Left 800 60 90 New. N/A Back Wall 2 Casita 2 R-19 Wall 90 Back 600 90 New N/A Right Wall 2 Casita 2 R-19 Wall 180 Right 800 90 New N/A Roof 3 Casita 2 R-38 Roof Attic 559 New N/A OPAQUE SURFACES-- Cathedral Ceilings 02 . 03 04 05 06 07 08 09 10 11 12 13 �,'°✓ a� Roof Framin Verified I Orientatio Area Skylight Roof Rise Roof Roof Reflectan Roof g Existing etns Zone Typen (ft2) Area (ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor Status Condifion m Riof`r &o 8 I Casita 2 R-38 Roof Attic1 Front 1.1 1 0 0 0 0.1 0.85 0.07 New N/A M0 -Tj 0 `� '--4 —iin'<c: 00'0.2 �> Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion.xml CF1 R -PRF -01 Page 4 of 9 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Statu s Verified Existing Condition Attic Casita Attic RoofCasita Ventilated 0 0.1 0.85 No No Existi ng No Attic Casita 2 Attic RoofCasita 2 Ventilated 0 0.1 0.85 Yes No New No WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Front -270) 3.0 8.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No Window 2 Front Wall (Front -270) 3.0 8.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No Window 3 Front Wall (Front -270) 3.0 8.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No Window 4 Right Wall (Right -180) 6.0 8.0 1 48.0 0.45 0.36 Insect Screen (default) New N/A Window 5 Right Wall (Right -180) 1.5 3.0 1.333 6.0 0.45 0.36 Insect Screen (default) New N/A Window 6 Right Wall (Right -180) 1.5 3.0 1.333 6.0 0.45 0.36 Insect Screen (default) New N/A Window 7 Front Wall 2 (Front -270) 3.0 8.0 1 24.0 0.34 0.29 Insect Screen (default) New N/A Window 8 Front Wall 2 (Front -270) 3.0 8.0 1 24.0 0.34 0.29 Insect Screen (default) New N/A Window 9 Left Wall 2 (Left -0) 3.0 5.0 1 15.0 0.34 0.29 Insect Screen (default) New N/A Window 10 Left Wall 2 (Left -0) 3.0 5.0 1 15.0 0.34 0.29 Insect Screen (default) New N/A C7 Window 11 I Left Wall 2 (Left -0) 3.0 5.0 1 15.0 0.34 0.29 Insect Screen (default) New N/A Window 12U �� I Left Wall 2 (Left -0) 3.0 5.0 1 15.0 0.34 0.29 Insect Screen (default) New N/A y ighti=- Roof (Front -270) -- --- 1 1.0 0.45 0.36 None New N/A f U� MOD .7 C<mc) i_< mC: oho �> Registration Num er: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -08252015-744 Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Description: Title 24 Analysis Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Input File Name: Tompkins Casita Addtion.xml CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 os 06 –0-7-7-08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent R Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0' 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 10 0 0 0 0 0 0 Window 11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 12 2 0.1 2 2 0 0 0 0 0 0 0 0 0 M C 0 90 _4D C<MC) n � —i -G C: 171o �> e -Number. CA Building Energy Efficiency Standards - 2013 Residential Compliance N Registration Date/Time: Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion.xml CF1 R -PRF -01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 05 06 07 08 Total Cavity Winter Design 0 Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Verified �7 • Cavity/Frame: no insul. /2x4 Top Chrd Perimeter Carpeted 2x4 Top Chord of Roof Truss @ 24 Existing Roof Deck: Wood Siding/sheathing/decking Attic RoofCasita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Heated Status Condition • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 tp US`ab_orf rad& i Casita 297 53 None • Exterior Finish: Wood Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R11 0.103 Siding/sheathing/decking 560 53 None 0.8 No New • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Floor Joists: R-9.9 insul. • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCasita 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt'Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. Rig 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 , Over Floor Joists: R-28.9 insul.. • Inside Finish: Gypsum Board • Cavity /Frame: R -38/2x4 • Roof Deck: Wood Siding/sheathing/decking f ---R-38 Roof Atti61----1 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.036 Roofing: Light Roof (Asphalt:Shingle) 1 i; m " I SLAB FLOQRS_ C :::4- 0 Q1J- —� I 02 02 03 04 05 06 07 08 09 0 Verified �7 Perimeter Carpeted Existing Q Name Zone Area (ft (ft) Edge Insul. R -value Fraction Heated Status Condition tp US`ab_orf rad& i Casita 297 53 None 0.8 No Existing No 1a�n"Grad 2` Casita 2 560 53 None 0.8 No New No o M �> Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion'xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — CFI R -PRF -01 Page 7 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.58 EF 43000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPADE CONDITIONIN�GLSYS1jEMS m 01-n _ 02 03 04 05 06 07 08 09 Heating System Cooling System �y Distribution Fan Floor Area Verified Existing Namek" 7 System Type Name Ducted Name Ducted System System Served Status Condition IJU Casital �O Other Heating and n @Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 857 Existing No W '"' _ 71 _ I H AC - HEWTING&Yf TEMS —22 1 t 1 -t i� 01 02 03 z (T7 e-- PName Type Efficiency __4HealiinglComponent 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-082S201S-744 Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion:xml CF1 R -PRF -01 Page 8 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Verified Duct Location Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A Location system Status Condition. Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Insulation Supply Duct Return Duct — --- I --- Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition. Verification Air Distribution Ducts located in attic Existing (not 8.0 Attic Attic None Existing No N/A System 1 specified) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A --- — --- I --- IAQ (indoor Air Quality) FANS 01 02 03. 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required m C 0 n �Z ot�� 0 C/) C: < M.0 a oC)o egistration Numb7-1 -0 -CAZuildjag Energy Efficiency Registration Date/Time: :andards - 2013 Residential Compliance Report Version - CF111-08252015-744 HERS Provider: Report Generated at: 2016-01-23 16:47:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Calculation Date/Time: 16:48, Sat, Jan 23, 2016 Calculation Description: Title 24 Analysis Input File Name: Tompkins Casita Addtion.xml CF1 R -PRF -01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan D. Hacker 0 417 94 Company: Signatu D e: Insu-form, Inc. 1/23/2016 Address: 72875 Fred Waring Drive, Suite C CEA/HERS Certification Identification (If applicable): City/StateQip:m Desert, Ca 92260 F Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent wit the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this buildi g permit application. Res pons le D nef qme: Responsible Desi er Signature: Company: L. C ---'K 4 -ISS l �oIV G� L�� l O G . Date Signe / 2 v--> Addre License: City/state/Zip: Phone: >o 0TH 0 z-Ms0 �0D� TJ m 0 -� 00o eeistration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CFSR-08252015-744 HERS Provider: Report Generated at: 2016-01-23.16:47:26 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Tompkins Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 1/23/2016 Project Address 80-425 Riviera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 857 Addition 560 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Wall Wood Framed R11 2,569 Existing Roof Wood Framed Attic R 19 297 Existing Slab Unheated Slab -on -Grade - no insulation 297 Perim = 53' Existing Wall Wood Framed R 19 2,592 New Roof Wood Framed Attic R38 559 New Slab Unheated Slab -on -Grade - no insulation 560 Perim = 53' New FENESTRATION Orientation Area ft2 I Total Area: 241 Glazing Percentage: 28.1 %New/Altered Average U -Factor. U -Fac SHGC Overhang Sidefins Exterior Shades 0.38 Status Front (119 72.0 0.710 0.73 2.0 none Bug Screen Existing Right (S) 48.0 0.450 0.36 8.0 none Bug Screen New Right (S) 12.0 0.450 0.36 2.0 none Bug Screen New Front (lo 48.0 0.340 0.29 2.0 none Bug Screen New Left (IV) 60.0 0.340 0.29 2.0 none Bug Screen New Skylight 1.0 0.450 0.36 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Casita Ducted Ducted Attic 8.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distributio,;n I ��- o $tatUS 1-J-1 W IV I Ak rr% r'a nU V ED 1 in vIv51 RUCTION H7 EnerqvPro6.7 by Ener Soft User Number: 2655 RunCode: 2016-01-23716:59:58 ID: Pae 12 of L Ufk I I:__ BY I 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance aDDroach used. Exceptions may annly Review the ro.mortivv rnd,,cortinn Ar mnro inArmnlinn Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §I10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-11l(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §I 10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be Rasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. § 150.0(8)1: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. §150.0(8)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class H vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of §150.0(8)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)lA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. _ § ] 50.0(j)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water re tdg NOternx s, av�R �ilZ ezte r""a� insulation or R-16 internal insulation where the internal insulation R -value is indicated . Y Y on,ttre,e, tenor of the W. For domestic hot water system piping, whether buried or unburied: the fust 5 feet of h6"t ledl'd%watei Oioefrom theistoi ge tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with, �d me: tdb hot water" recirciila ' n syste §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tankior betwee ianksb piping bufieVbWow de, and all hot water pipes from the heating source to kitchen fixtures must be insulated accordruyot, Q"Ii�emeerlWRf O�t 1203- A. i §150.0(j)2B: All domestic hot water pipes that are buried below grade must be installed in a water. roof and non-cri$ able casing or sleeve that allows for installation, removal and replacement of the enclosed pipe and insula. _ 2013 Low -Rise Residential Mandatory Measures Summary §150.06)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)]: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §1103(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing a ency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '14 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet meta], painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CF i as confi_rm-fief verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. I r T T 4 1 11 N { TA §150.0(o): All dwelling units shall meet the requirements of ASHRAE Standard 62.2. �eithe ,wjn�d o�erat'o-n nor FcontiiiMdds 6peratton central forced air system air handlers used in central fan integrated ventilation systems ar rrtussible meth6'ds of providing Q of Whole Building Ventilation. I A 0 171 r --NX f t- F § 150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and dia os6c testing`, iii accordanck with Reference Residential Appendix RA3. FUR CONS I RUC fION Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that'complies with the jipliance Efficiency .4(a): F§I - Regulations; an on-off switch mounted outside of the heater that allows shutting offthe heater wit out ad�us m -ng )lHe-fiTerm�tat settin • a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- ammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § 150.0(k)]B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of §150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)] C: §1 30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)]E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer §150.0(k)2G: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other requirements in §150.0 2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it §150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy,or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditionedspases-sealed-with-a-gask-et or caul ;-an` allow ballast maintenance and replacement without requiring cutting holesin theiceilin� ('� p A For with ' recessed compact fluorescent luminaries with ballasts to qualify as high efficacy fdr coni lian'ee 0��(!k the tiall is shall be certified to the Ener Commission to comply with thea licable�re uremen. ' 1`10:9. 'A ETY DEPT. For single-family residential buildings, outdoor lighting permanently mounted 4o a iesi al::buildin� g gr�othe�r-bu�ings on e `s; same lot shall be high efficacy, or may be low efficacy if it meets all of theli following e utmen V �/ i. Controlled by a manual ON and OFF switch that does not override to ON the automat cft5ns of I e -'T'"` 1 vJ X nUt,9r+4Lli` low; and § 150.0(k)9A: e �y}s�al,fir ii. Controlled by a motion sensor not having an override or bypass switch that disables the motron sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and I DATE BY iii. Controlled by one of the followin methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, §130.4, §140.7 and §141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §I 10.10(b) through §110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the . building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § l 10.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. 01 I IT The main electrical service panel shall have a reserved space to allow for the instlllafieh a oubfe pole-eircuiWr6akd9Mr a §110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the oppositL&PdLi>;c@n&1>ve^. ;fipuffee4er[ldL-4 Tn or main circuit location, and permanently marked as "For Future Solar Electric'. FOR CONSTRUCTION PATE BY HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Tompkins Residence 1/23/2016 System Name Floor Area Casita 857 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,425 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heatin 'S stem Sensible Latent CFM Sensible Output perSystem 35,000 27,661 964 909 32,177 Total Output Btuh 35,000 0 Output (Btuh/sqfty 40.8 1,597 1,581 Cooling System 0 Output perSystem 24,000 0 0 0 0 Total Output Btuh 24,000 0 964 0 Total Output Tons 2.0 1,597 1,581 Total Output Btuh/s ft 28.0 Total Output s ft/Ton 428.5 30,855 35,339 Air System CFM perSystem 855 HVAC EQUIPMENT SELECTION Airflow cfm 855 BDP CO. 395CAV024045 15,889 41536 35,000 Airflow cfm/s ft 1.00 Airflow cfm/Ton 427.5 Outside Air % 0-0% Total Adjusted System Output 15,889 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,536 Aug 3 PM 35,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 105 OF 105 OF ► �� Outside Air 0 cfm Heating Coil Supply Fan 103 OF 855 cfm ROOM '! ., 9� 68 OF 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 77/62°F 55/54°F 55/54°F V Orv� Outside Air 0 cfm Cooling Coil Supply Fan 855 cfm 2-91 t „y Rookl17 77/62OF BUIL 1 0 oACr: °' =_PT. 754-62-9 A FOR I ��� P �� t;"" CONSTRUCTION EnergyPro 6.7 by EnergySoR User Number: 2655 RunCode: 2016-01-23716:59:58 /D: F3Y Page 17 of 17