9907-116 (SFD)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
47868,0 F j 02129!2(
Date ' elr Signature of Contractor --�
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:.
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( R),A. have and will maintain workers' compensation insurance, as required by,
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & 'policy no. are:
Carrier (jOLDF 1 krjLE Policy No. NWC547W1400
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' Compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those,provisions.
Date: ti - )/JApplicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees. \
IMPORTANT Application is hereby made to the. Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application. _
1. Each person upon•whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit,issued as a result of this applicaton agrees to, & shall, indemnity
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if ,
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agent) �:'" Date/yam
BUILDING PERMIT PERMIT#
GPM -
DATE VALUATION LOT TRACT
$296,114.60 T28603
JOB SITE
APN
ADDRESS ft -12 RYVJ�RRA
.761—M4M
OWNER
CONTRACTOR / DESIGNER / ENGINEER
30LT.iIWI" HiI..z.S %.LC
R.C. HOBBS dba SOLTTBF" HitiS, LLC
1430 E GWNM AVE FrE? 100
55.960 PGABLVD
ORANGE CA 92886
LA QUINT13 CA 92253
(714)6333-7260 C;13I., ' 5487
USE OF PERMIT
SINGLE FA1bM.Y Di;EZ.L1W
3FD - LOT 3 PLAN N 2C:R PERMIT DOES NOT INCLUDE BLOCK WALL OR
P0O1.'7SV6 PLAN CH CK REDUCT ION APPLIED FOR. (MULTIPLE SUBMITTAL
CUSTOM CmTRUCTION 3,524.00 SF
PORCHIPATIO 430.00 Sty
GARAGE/CARPORT 810100 SF
:ES'TIKATJW COS' OF C0NYI-RUMON,
296,1.14.6((
PE'11~it!t T FEE WbWA E2Y
CONSTRUCTION FEE 101.000-118-000 $1,329.00
PLAN CHECK FEE 101-000-439-318 $273.66
MECHANICAL FEE 101-000.421.000 $129.50
ELECTRICAL, FEE 101-000-420.000 $19'704
'PLUMBING FEE 101.000.419-000 $235.00
STRONO MOTION FEE - RESID 101-000-241-000 $29:51
GRACiIt O Fl~8 101n000-423-000 120,00
DEVELOPER IMPACT FEE $1,907.00
ART IN PUBJAC PLACES - RESM 701-000.255.000 $740,24
SUE -TOTAL CONST'R.UMON AND PIAT CHECK
$4,360.10
7• SS PRE -PAID NZ%
$0.00
1WAL YEKIRNAT FREES DUE NOW
RECEIPT
DATE
BY
DATE FINALED
INSPECTOR
lfL
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
op
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
U56,
Combustion Air
Roof Deck
Exhaust Fans
O.K to Wrap1,6
X,
F.A.U.
Framing
Ej
Compressor
Vents
Insulation p
Fireplace FI.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS - SPAS
BLOCKWALL
AP ROVA S
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
Certificate of Occupancy
City La Quinta
of
Building and Safety Department
f
This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code,
certifying that, at the. time of issuance, this structure was in compliance with the various ordinances
of the City regulating building construction or use. For the following.-
BUILDING
ollowing.BUILDING ADDRESS:. 80-432 RIVIERA
Use Classification: SINGLE FAMILY DWELLING Bldg. Permit No.: 9907-116
Occupancy Group: R-3 Type of Construction: VN ' Land Use Zone: RL
Owner of Building: SOUTHERN HILLS LLC Address: 1430 E . CHAPMAN AVE STE 100
City: ORANGE, CA., 92886
By: DANIEL P. CRAWFORD JR.
-Date: 3/21/01
Building Official
POST IN A CONSPICUOUS PLACE
3 Y001 y y 3- , 5' 9 6 K �_v� e
• " TITLE 24 REPORT _
CITY OF LA QUINTA
BUILDING 8 SAFETY DEPT.
Title 24 Report for: APPROVED
Montecito Guest House .FOR CONSTRUCTIO
All Orientations
La Quinta, CA DATE BY
Project. Designer:
.Report Prepared By:
Joan D. Hacker
Insu-form Inc.
68255 Corta Road
Cathedral City, CA 92234 "
(760) 824-0216,
Job Number:
Date:
.12/6/00
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential'1998 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 2.1 By EnergySoft Job Number: User Number: 2655
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2,
Form CF -1 R Certificate of Compliance 3
Form ,MF -1 R Mandatory Measures Checklist 5
Form C-2kComputer Method Summary 6.
HVAC System Heating and Cooling Loads Summary g
Room Load Summary - 10
l � .
l
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Montecito Guest House 12/6/00
Project Title Date
All Orientations La Quinta
Project Address Building Permit #
Insu-form Inc. (760) 324-0216 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check I Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 449 ft2
Total Conditioned Slab Area: 449 ft2
Building Type:
Orientation Area
(check one or more)
Interior
® Single Family Detached (SFD)
❑ Addition Alone
❑ Single Family Attached (SFA)
❑ Existing Building
❑ Multi -Family
❑ Existing Plus Addition
Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor.
Number 'of Dwelling Units: 1.00
Number of Stories:
1 ❑ Raised Floor
FENESTRATION ShadinA Devices
Type
Orientation Area
Const.
Interior
Component
p
Frame
Assembly
Location/Comments
Type
Type
U -Value
(attic, garage, typical, etc.)
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
R-13 Wall (W.13.2x4.16)
Wood
0.081
Exterior Wall
R-38 Roof (R.38.2xl4.16)
Wood
0.028
Exterior Roof
FENESTRATION ShadinA Devices
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
SF
U -Value SHGC
roller blind, etc.
shadescreen etc.
Yes / No
Yes / No
Front
48.0
0.85 0.59
Drapery
Bug Screen
x❑ ❑
❑ X❑
Left
30.0
0.50 0.53
Blind
Bug screenX❑
❑
❑ X❑
Left
8.0
0.50 0.53
Drapery
Bug ScreenX❑
❑
❑ X❑
Rear
30.0
0.49 0.55
Blind
Bug Screen
X❑ ❑
❑ X❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
Run Initiation Time: 12/06/00 23:23:26
Run Code: 976145008
Ener
Pro 2.1 By Ener Soft
User Number: 2655
Job Number:
Pa e:3 of 10
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Montecito Guest House 12/6/00
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
Central Furnarp 80% AFUE Ducts in Attic 4.2 Setback Casita
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location
heat pump, evap. cooling) (SEER) (attic, etc.)
Duct Thermostat Location /
R -Value Type Comments
Split Air Conditioner 11.0 SEER Ducts in Attic 42 Sethack Casita
WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value
RHEEM 44V40-1 Small Gas Standard 1 40.000 39 0.63 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
%rU1V1r-LIAI4t+C J I A I CIYICIY 1
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Ad; AGjkjz 5 CO. Name: Joan D. Hacker
Title/Firm:
Address: 5.; — -SI
�'J h� f , �i-ZZ4
Telephone:
Enforcement Agency
Name: _
Title/Firm:
Address:
Telephone_
Title/Firm: Insu-form Inc.
Address: 68255 Corta Road
Cathedral City, CA 92234
Telephone: (760) 324-0216
(sig
(signature/stamp) (date)
Run Initiation Time: 12/06/00 23:23:28 Run Code: 976145008
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: PageA of 10
• Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties
as binding minimum component specifications.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMEN•
Building Envelope Measures
❑ '§ 150(.): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -value.
❑ '§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls).
❑ '§ 150(d): Minimum R-13 raised floor insulation in wood framed floors.
❑ § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 permfinch.
❑ §118: Insulation specified or installed meets quality standards. Indicate type and form.
❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑ *1 50(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA.
§150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑ §1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined intemal/external insulation, piping between heat source and tank insulated. '
3.lnsulation on the first 5' of pipes closest to water healer tank, non -recirculating systems (R4 or greater), buried or exposed
piping in recirculating sections of hot water systems, cooling system piping below 55 deg F.
❑ '§150(m): Ducts and Fans
1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections
601603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be,
sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181,
UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m).
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated
dampers.
❑ §114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating.
2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light.
Lighting Measures
❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
❑ 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 Iumenstwatt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed
ceiling are IC (insulation cover) approved.
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 10
" Computer Method Summary (Part 1 of 3) C -2R
Montecito Guest House 12/6/00
Project Title Date
All Orientations La Quinta
Project Address Building Permit #
Insu-form Inc. (760) 324-0216 Plan Check/Date
Documentation Author Telephone
Computer Performance 15 Field Check/Date
Compliance Method (Package or Computer Cimate Zone
Source Energy Standard
Use (kBtu/sf-yr) Design .
Facing
North Margin
�
Facing
East Margin
Facing
South Margin.
Facing
West Margin
6.60 -0.98
5.88 -0.26
6.65 -1.03
7.04 -1.42
Space Heating 5.62
Space Cooling 70.65
73.30 -2.66
79.10 -8.45
.77.23 -6.59
75.52 -4.88
Domestic Hot Water 41.31
1 32.56 8.75
32.56 8.75
32.56 8.75
32.56 8.75
Totals
BUILDING
COMPLIES
This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence.
This plan has been analyzed with identical features in all orientations.
GENERAL INFORMATION
Conditioned Floor Area: 449 Floor Construction Type: ❑X Slab Floor
Building Type: Single Fam Detached
Building Front Orientation: All Four Orientations ❑Raised Floor
Number of Dwelling Units: 1.00 Total Conditioned Volume: 4,939
Number of Stories: 1 Slab Floor Area: 449
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
Cacita 449 4939 1 nn CnnriitinnPd SPthank -2 n/a
OPAQUE SURFACES
Type Area U -Val
Act.
Azm.
Solar
Gains
Tilt Y / N
Form 3 Reference
Location / Comments
Wall 157 0.081 0 gQ
wall 276 0.081 gn go
Wall 175 0.081 180 A()
Wall 314 0.081 270 gQ
Rnnf 449 .0.028 _Q a
�
R-13 Wall ON 132x4.16) rasita
R-13 Wall (W 13 2x4 16) Cacita
R-13 Wall fW 13 2x4 16) Cacita
R-13 Wall M/.132x4.16) Casita
2x14.16) Casita
❑Run
Initiation Time@ 12/06/00 212128 Run Code* 976145008❑
EnergyPro 2.1 By Energysoft User Number: 2655 Job Number: Page:6 of 10
Computer Method Summary (Part 2 of 3) C -2R
Montecito Guest House 12/6/00
Project Title Date
FENESTRATION SURFACES
U. -Value Act. Glazing Type Location/
.# Type Area SHGC Azm. Tilt Comments
_1_
Window Front
(North)
48.0
0.850 0 59
_n
An Douhle MH Tinted Default
Casita
2
Window Left
(East)
30.0
0.500 0.53
90
.90 Award Windows Dual Tint
Casita
3
Window Left
(East)
8.0
0.500 0.53
90
90 Award Windows Dual Tint
Casita
4
-
Window Rear
(South)
30.0
0.490 0.55
180
90 Award Windows Dual Tint
Casita
i
INTERIOR AND EXTERIOR SHADING
Window Overhang
Left Fin Right Fin
#
Interior Shade Type
SHGC Exterior Shade Type
SHGC
Hgt. Wd. Len. Hgt. LExt. REM.
Dist. Len. Hgt. Dist. Len. Hgt.
1
Drapery
0.68 Bug
Screen
0.76
8.0 3.0 2.0 . 0.1 2.0 2.0
2
Blind
0.47 Bug
Screen
0.76
5.0 3.0 2.0 0.1 2.0 2.0
- - -
3
Drapery
0.68 Bug
Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0-
- _ -
4
Blind
0.47 Bug
Screen
0.76
2.; 40 2 0 01 20 2 0
-
-
- -
- - -
EnerayPro 2.1 By EnergySoft User Number: 2655 Job Number: Pane:7 of 10
Computer Method Summary (Part 3 of 3) C -2R
Montecito Guest House 12/6/00
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 95 0_76 0.0 _ 0 Casita
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiencyy and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Casita
Hydronic Piping I pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum • Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location
heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments
Split Air Conditioner 11.10SEER Ducts in Attic 4.2 Setback Casita
WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul.
Water Heater Water Heater Distribution # in ' Input Cap. or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (al) Efficiency Loss (%) Ext
RHEEM 44V40-1 Small Gas Standard 1 40,000 39 0.63 n/a n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 12/06/00 23:23:28 Run Code: 976145008
EnergyPro 2.1 By EnergySoft User Number. 2655 Job Number: Pa e:8 of 10
4� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Montecito Guest House 12/6/00
SYSTEM NAME FLOOR AREA
Casita ddQ
:ATING SYSTEM PSYCHROME
26.0 of 69.4 of
Outsidir
e At
0 cfm
Supply Fan
1215 cfm
69.4 of
11.0 / 77.4 of
Outside Air
0 drn
78.4/68.9 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
12 597 1 157 16 760
CARRIER 38CMCO243" 12,908 9.368 37,000
Total Adjusted System Output 12,908 9,368 37,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
RICS (Airstream Temperatures at Time of Heatina Peak)
69.4 of = 97.8 of
Heating Coil
h Return Air Ducts `{
PSYCHROMETRICS (Airstream Temperatures at Time of
78.4 / 68.9 OF 78.4 / 68.9 of M 68.5 / 65.6 of
Supply Fan Cooling Coil
1215 drn
h Return Air Ducts `S
Supply Air Ducts
97.2 OF
ROOMS
70.0 of
Supply Air Ducts
69.0 / 65.7 of
63.1% R.H. ROOMS
78.0 / 68.7 of
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page.9 of 10
'ROOM LOAD SUMMARY
PROJECT NAME
DATE
Montecito Guesf House
12/6/00
SYSTEM NAME
FLOOR AREA
Casita
449
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
ISENSIBLE
LATENT
CFM
SENSIBLE
Casita
Casita
1
1,183
11,452
1,157
1,1831
11,452
1,157
522
15,236
PAGE TOTAL 1 1,183 11,452 1,157
TOTAL 1 1,183 11,452 1,157
522
15,236
522
15,236
EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 10