Loading...
9907-116 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 47868,0 F j 02129!2( Date ' elr Signature of Contractor --� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason:. ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( R),A. have and will maintain workers' compensation insurance, as required by, Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & 'policy no. are: Carrier (jOLDF 1 krjLE Policy No. NWC547W1400 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' Compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those,provisions. Date: ti - )/JApplicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. \ IMPORTANT Application is hereby made to the. Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. _ 1. Each person upon•whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit,issued as a result of this applicaton agrees to, & shall, indemnity & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if , work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent) �:'" Date/yam BUILDING PERMIT PERMIT# GPM - DATE VALUATION LOT TRACT $296,114.60 T28603 JOB SITE APN ADDRESS ft -12 RYVJ�RRA .761—M4M OWNER CONTRACTOR / DESIGNER / ENGINEER 30LT.iIWI" HiI..z.S %.LC R.C. HOBBS dba SOLTTBF" HitiS, LLC 1430 E GWNM AVE FrE? 100 55.960 PGABLVD ORANGE CA 92886 LA QUINT13 CA 92253 (714)6333-7260 C;13I., ' 5487 USE OF PERMIT SINGLE FA1bM.Y Di;EZ.L1W 3FD - LOT 3 PLAN N 2C:R PERMIT DOES NOT INCLUDE BLOCK WALL OR P0O1.'7SV6 PLAN CH CK REDUCT ION APPLIED FOR. (MULTIPLE SUBMITTAL CUSTOM CmTRUCTION 3,524.00 SF PORCHIPATIO 430.00 Sty GARAGE/CARPORT 810100 SF :ES'TIKATJW COS' OF C0NYI-RUMON, 296,1.14.6(( PE'11~it!t T FEE WbWA E2Y CONSTRUCTION FEE 101.000-118-000 $1,329.00 PLAN CHECK FEE 101-000-439-318 $273.66 MECHANICAL FEE 101-000.421.000 $129.50 ELECTRICAL, FEE 101-000-420.000 $19'704 'PLUMBING FEE 101.000.419-000 $235.00 STRONO MOTION FEE - RESID 101-000-241-000 $29:51 GRACiIt O Fl~8 101n000-423-000 120,00 DEVELOPER IMPACT FEE $1,907.00 ART IN PUBJAC PLACES - RESM 701-000.255.000 $740,24 SUE -TOTAL CONST'R.UMON AND PIAT CHECK $4,360.10 7• SS PRE -PAID NZ% $0.00 1WAL YEKIRNAT FREES DUE NOW RECEIPT DATE BY DATE FINALED INSPECTOR lfL INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs op Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel U56, Combustion Air Roof Deck Exhaust Fans O.K to Wrap1,6 X, F.A.U. Framing Ej Compressor Vents Insulation p Fireplace FI.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL AP ROVA S Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) Certificate of Occupancy City La Quinta of Building and Safety Department f This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the. time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following.- BUILDING ollowing.BUILDING ADDRESS:. 80-432 RIVIERA Use Classification: SINGLE FAMILY DWELLING Bldg. Permit No.: 9907-116 Occupancy Group: R-3 Type of Construction: VN ' Land Use Zone: RL Owner of Building: SOUTHERN HILLS LLC Address: 1430 E . CHAPMAN AVE STE 100 City: ORANGE, CA., 92886 By: DANIEL P. CRAWFORD JR. -Date: 3/21/01 Building Official POST IN A CONSPICUOUS PLACE 3 Y001 y y 3- , 5' 9 6 K �_v� e • " TITLE 24 REPORT _ CITY OF LA QUINTA BUILDING 8 SAFETY DEPT. Title 24 Report for: APPROVED Montecito Guest House .FOR CONSTRUCTIO All Orientations La Quinta, CA DATE BY Project. Designer: .Report Prepared By: Joan D. Hacker Insu-form Inc. 68255 Corta Road Cathedral City, CA 92234 " (760) 824-0216, Job Number: Date: .12/6/00 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential'1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2, Form CF -1 R Certificate of Compliance 3 Form ,MF -1 R Mandatory Measures Checklist 5 Form C-2kComputer Method Summary 6. HVAC System Heating and Cooling Loads Summary g Room Load Summary - 10 l � . l Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Montecito Guest House 12/6/00 Project Title Date All Orientations La Quinta Project Address Building Permit # Insu-form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 449 ft2 Total Conditioned Slab Area: 449 ft2 Building Type: Orientation Area (check one or more) Interior ® Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor. Number 'of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION ShadinA Devices Type Orientation Area Const. Interior Component p Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.081 Exterior Wall R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof FENESTRATION ShadinA Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc. shadescreen etc. Yes / No Yes / No Front 48.0 0.85 0.59 Drapery Bug Screen x❑ ❑ ❑ X❑ Left 30.0 0.50 0.53 Blind Bug screenX❑ ❑ ❑ X❑ Left 8.0 0.50 0.53 Drapery Bug ScreenX❑ ❑ ❑ X❑ Rear 30.0 0.49 0.55 Blind Bug Screen X❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 12/06/00 23:23:26 Run Code: 976145008 Ener Pro 2.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 10 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Montecito Guest House 12/6/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnarp 80% AFUE Ducts in Attic 4.2 Setback Casita Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc.) Duct Thermostat Location / R -Value Type Comments Split Air Conditioner 11.0 SEER Ducts in Attic 42 Sethack Casita WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value RHEEM 44V40-1 Small Gas Standard 1 40.000 39 0.63 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS %rU1V1r-LIAI4t+C J I A I CIYICIY 1 This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Ad; AGjkjz 5 CO. Name: Joan D. Hacker Title/Firm: Address: 5.; — -SI �'J h� f , �i-ZZ4 Telephone: Enforcement Agency Name: _ Title/Firm: Address: Telephone_ Title/Firm: Insu-form Inc. Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-0216 (sig (signature/stamp) (date) Run Initiation Time: 12/06/00 23:23:28 Run Code: 976145008 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: PageA of 10 • Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN• Building Envelope Measures ❑ '§ 150(.): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -value. ❑ '§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). ❑ '§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 permfinch. ❑ §118: Insulation specified or installed meets quality standards. Indicate type and form. ❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ *1 50(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/external insulation, piping between heat source and tank insulated. ' 3.lnsulation on the first 5' of pipes closest to water healer tank, non -recirculating systems (R4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. ❑ '§150(m): Ducts and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be, sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m). 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 Iumenstwatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 10 " Computer Method Summary (Part 1 of 3) C -2R Montecito Guest House 12/6/00 Project Title Date All Orientations La Quinta Project Address Building Permit # Insu-form Inc. (760) 324-0216 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (Package or Computer Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design . Facing North Margin � Facing East Margin Facing South Margin. Facing West Margin 6.60 -0.98 5.88 -0.26 6.65 -1.03 7.04 -1.42 Space Heating 5.62 Space Cooling 70.65 73.30 -2.66 79.10 -8.45 .77.23 -6.59 75.52 -4.88 Domestic Hot Water 41.31 1 32.56 8.75 32.56 8.75 32.56 8.75 32.56 8.75 Totals BUILDING COMPLIES This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence. This plan has been analyzed with identical features in all orientations. GENERAL INFORMATION Conditioned Floor Area: 449 Floor Construction Type: ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: All Four Orientations ❑Raised Floor Number of Dwelling Units: 1.00 Total Conditioned Volume: 4,939 Number of Stories: 1 Slab Floor Area: 449 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Cacita 449 4939 1 nn CnnriitinnPd SPthank -2 n/a OPAQUE SURFACES Type Area U -Val Act. Azm. Solar Gains Tilt Y / N Form 3 Reference Location / Comments Wall 157 0.081 0 gQ wall 276 0.081 gn go Wall 175 0.081 180 A() Wall 314 0.081 270 gQ Rnnf 449 .0.028 _Q a � R-13 Wall ON 132x4.16) rasita R-13 Wall (W 13 2x4 16) Cacita R-13 Wall fW 13 2x4 16) Cacita R-13 Wall M/.132x4.16) Casita 2x14.16) Casita ❑Run Initiation Time@ 12/06/00 212128 Run Code* 976145008❑ EnergyPro 2.1 By Energysoft User Number: 2655 Job Number: Page:6 of 10 Computer Method Summary (Part 2 of 3) C -2R Montecito Guest House 12/6/00 Project Title Date FENESTRATION SURFACES U. -Value Act. Glazing Type Location/ .# Type Area SHGC Azm. Tilt Comments _1_ Window Front (North) 48.0 0.850 0 59 _n An Douhle MH Tinted Default Casita 2 Window Left (East) 30.0 0.500 0.53 90 .90 Award Windows Dual Tint Casita 3 Window Left (East) 8.0 0.500 0.53 90 90 Award Windows Dual Tint Casita 4 - Window Rear (South) 30.0 0.490 0.55 180 90 Award Windows Dual Tint Casita i INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len. Hgt. Dist. Len. Hgt. 1 Drapery 0.68 Bug Screen 0.76 8.0 3.0 2.0 . 0.1 2.0 2.0 2 Blind 0.47 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 - - - 3 Drapery 0.68 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0- - _ - 4 Blind 0.47 Bug Screen 0.76 2.; 40 2 0 01 20 2 0 - - - - - - - EnerayPro 2.1 By EnergySoft User Number: 2655 Job Number: Pane:7 of 10 Computer Method Summary (Part 3 of 3) C -2R Montecito Guest House 12/6/00 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 95 0_76 0.0 _ 0 Casita HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Casita Hydronic Piping I pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum • Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 11.10SEER Ducts in Attic 4.2 Setback Casita WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in ' Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (al) Efficiency Loss (%) Ext RHEEM 44V40-1 Small Gas Standard 1 40,000 39 0.63 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 12/06/00 23:23:28 Run Code: 976145008 EnergyPro 2.1 By EnergySoft User Number. 2655 Job Number: Pa e:8 of 10 4� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Montecito Guest House 12/6/00 SYSTEM NAME FLOOR AREA Casita ddQ :ATING SYSTEM PSYCHROME 26.0 of 69.4 of Outsidir e At 0 cfm Supply Fan 1215 cfm 69.4 of 11.0 / 77.4 of Outside Air 0 drn 78.4/68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 12 597 1 157 16 760 CARRIER 38CMCO243" 12,908 9.368 37,000 Total Adjusted System Output 12,908 9,368 37,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Temperatures at Time of Heatina Peak) 69.4 of = 97.8 of Heating Coil h Return Air Ducts `{ PSYCHROMETRICS (Airstream Temperatures at Time of 78.4 / 68.9 OF 78.4 / 68.9 of M 68.5 / 65.6 of Supply Fan Cooling Coil 1215 drn h Return Air Ducts `S Supply Air Ducts 97.2 OF ROOMS 70.0 of Supply Air Ducts 69.0 / 65.7 of 63.1% R.H. ROOMS 78.0 / 68.7 of EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page.9 of 10 'ROOM LOAD SUMMARY PROJECT NAME DATE Montecito Guesf House 12/6/00 SYSTEM NAME FLOOR AREA Casita 449 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM ISENSIBLE LATENT CFM SENSIBLE Casita Casita 1 1,183 11,452 1,157 1,1831 11,452 1,157 522 15,236 PAGE TOTAL 1 1,183 11,452 1,157 TOTAL 1 1,183 11,452 1,157 522 15,236 522 15,236 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 10