Loading...
9907-120 (SFD)- LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that, I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License# - LLic. Class Exp., Date ](5 ] 4.7M9 B j 02129/2( Date: -1 v Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property; or my employees with wages as their sole compensation, will do the" work, and the structure is not intended or offered for .sale (Sec. 7044, Business & Professionals Code). ( . ) I, as owner of the property, am exclusively, contracting with licensed contractors to construct the project (Sec. 7044, Business &,Professionals Code). () I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( )' I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700;of the Labor Code, for the performance of the -,work for which this permit is issued. { ,,,�I-have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no., are: Carrier CI0WEEN EA01,t3 Policy No., 1d PJC 5A7701400 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with thosT provisions. Date: - r1 JApplicant * Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to ,the conditions and restrictions set forth on his application. _ 1. Each person upon whose behalf this application is made & each person at Whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold. harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and. void if 'work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent) Date BU6LDING PERMIT PERMITk - DATE VALUATION LOT�� `== TRACT $7M,11.4,60 JOB SITE y APN ADDRESS L8 96-Rr exLi±R"• 761—CJ90-M OWNER fFi�i CONTRACTOR / DESIGNER / ENGINEER SOXATIERN ISI 's LLC 1430 E CItW"MAN A'S'E M7100 ORANGE CA USE OF PERMIT SWOLE F1�.1uTLY DWL15..I1 O RC. HOBBS dba SOUTSF.,13�T HU: -S, LLC 55-960 PGA BLVD 92886 T:.AQUINTA CA 92253 (714)633-7260 CBLO 5487 SFD - LOT 7 PLAN 2CR PERm1'I' DOES NOT INCLUDE BLOCK WALL Olt -' POOI,.75"x/0 PL&N C°,,tiEC RF?i's. U4;TION APPlitEO 'Mi R MUfoTIPLE SUBMITTAL CUSTOM CONSTRUCTION 3,524.00 SF PORCH/PAT10 430.00 SF GARAGEtC.A,RPOR'P 1310.00 SF k:FMATE COST OF CC'.IYFMCMION 2%,114.60 PERAM' fi`l 9Uhfl4A]E`Y CONS`IRUCTJON PEE 101.000-418-000 $1,329,00 PLAN CNECK FEE 101-000-439-318 MECHANICAL IEE 101-000-421-000 3129,50 RLECI,WCA1. FEX 101-000-420-.000 $19ZO4 PLUMBING FEE 101.000-419-000 $235.00 STR.ONO h40TICYN F70 - R SID 101 -000 -?.41-000 $29.61 ORADING FRE. 1.01.000.423m= $20.00 DEVELOPER IMPACT 1BE $1,907.00 ART IN PUBLIC PLACES - RL+SIL?01.000-255.000 E.240.a9 SUB -TOTAL, COX'`k2:UCMOX AND .?LAW C''i�FCTC $4a360.10 LESS pkZF,��•kyA11� :6'E?"Es $0.00 TOTAL PMWr 1t'FES DUE N01/+1 94,WAO RECEIPT DATE BY I DATE FINALED INSPECTOR r 6 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade / Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K.to Wrap p11SAW F.A.U. Framing Compressor Insulation Vents Fireplace Pt. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVAL9 POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPR VALS Gas Test Electric Final Waste Lines S Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: �s �iPL/✓ . r �'"'�" �" " ,�• 04f26/2001 19:10 FAX. 760+347+9879 EMERALD ROOFING Q02 Emerald Roofing Inc. . 83-600 Peach Street Indio, CA 92201 (760) 347-9869 April 27, 2001 Montecito At PGA West The R.C. Hobbs Company 55-487 Southern Hills La Quinta., CA 92253 To Whom It May Concern: Emerald Roofing has installed O'hagin vents at Montecito homes at PGA West below are the address and number of vents installed. Phase 4 Tract 428603-2 . . . I,,ot# Plan# Address # Of Vent 1 2 AR 80.400 Riviera 17 2 3 A _ 80-416 Riicra 16 ' 3 2 CR 80-432 Riviera 17 4 2 alt 80.448 Riviera 17 5. 3 C 80-464 Riviera 16 6 3 AR 80-180 Riviera 16 7 2 CR 80-512 Riviera 17 8 3 CR 80-512 Riviera 16 Thank You, John R, Jones President , ,MAR -06-2001 14:55 WESTERN INSULATION 909"686 8786 P.08i09 wimTERN I SZJLA'T'ION INC. 4211 1Atha- Street, Riverside, California 92501 TeL (909) 686.8760 Fax (909) 686-8786 INSULATION CERTIFICATE THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE CURRENT ENERGY REGULATION, CALIFORNIA ADMINISTRATIVE CODE, TITLE_ 24, STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT:. = . TRACT / PHASE: #28603-2/ PHASE 4;. n LOT#: 7 SITE ADDRESS: 80-496 RIVIERA. LA QUINTA, CA EXTERIOR WALLS: MANUFACTURER: JOHNS MANVILLE THICKNESS: 5.5 " R -VALUE: R-21 CEILINGS: BATTS �BLO MANUFACTURER GREENSTONE THICKNESS: 16 1/4 " A -VALUE: R-38 CEILINGS: �^ BLOW MANUFACTURER JOHNS MANVILLE THICKNESS: 10.3 R -VALUE: R-38 GENERAL CONTRACTOR: R.C. HOBBS COMPANY BY: TITLE: DATE: INSULATION -CONTRACTOR: WESTERN INSULATION, INC. LICENSE NUMBER: 481278 BY: TITLE. P140VCTION INAGER DATE MARCH 6, 2001 -of Oc' cupancyCertifica to-��- . . a.. Cityof La •Q•uinta 'Building, and Safety Department Of --> This Certificate issued pursuant to the requirements of Section 109 of the Uniform Bui/ding Code, certifying that, at the time of issuance, this structure was in comp/lance with the various ordinances of the City regulating building construction or use. For the following: 'BUILDING ADDRESS: s 80-496 RIVIERA Use Classification: SINGLE FAMILY DWELLING Bldg. Permit No.: 9907-120 Occupancy Group: R-3 Type •of- Construction: VN • Land Use Zone: • RL ' Owner of Building: SOUTHERN 'HILLS' LLC Address: 1430 E CHAPMAN AVE STE 100 - City: ORANGE, CA., 92886 By: DANIEL- P. CRAWFORD JR. Date: 4/27/01 ` Building Official \ POST IN A CONSPICUOUS PLACE - • ' TITLE 24 REPORT CITY OFLA QUINTA BUILDING 9 SAFETY DEPT, Title 24 Report for: APPROVED Montecito Guest House FOR CONSTRUCTIO All Orientations La Quinta, CA DATER BY Project Designer: ` Report Prepared By: Joan D. Hacker nsu-form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 a Job Number: Date: 12/6/00 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft - Job Number: User Number: 2655 ` y TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 5 Form C -2R Computer Method Summary g HVAC.System Heating and Cooling Loads Summary g Room Load Summary 10, 4 EnergyPro 2.1 By EnergySoR Job Number: User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Montecito Guest House 12/6/00' ' Project Title Date All Orientations La Quinta Location/Comments Project Address Building Permit # Insu-form Inc. - (760) 324-0216 Plan Check I Date Documentation Author Telephone Slab On Grade Computer Performance '15 Field, check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION - Total Conditioned Floor Area: 449 ft2 Exterior Wall Total Conditioned Slab Area: 449 ft2 Wood Building Type: Exterior Roof (check one or more) x❑ ❑ RI Single Family Detached (SFD) ❑ Addition Alone Left ❑ Single Family Attached (SFA) ❑ Existing Building 0.50 0.53 ❑ Multi -Family ❑ Existing Plus Addition Bug Screen Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 30.0 Number of Stories: 1 ❑ Raised Floor FENESTRATION Sh2dina Dpvir_ps Type Orientation Area • Const. Interior Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typica4 etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.081 Exterior Wall R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof Bug Screen x❑ ❑ FENESTRATION Sh2dina Dpvir_ps Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc. shadescreen, etc. Yes / No Yes / No Front 48.0. 0.85 0.59 Drapery Bug Screen X❑ ❑ ❑ X❑ Left 30.0 '0.50 0.53 Blind Bug Screen x❑ ❑ ❑ x❑ Left '� 8.0 0.50 0.53 Drapery Bug Screen X❑ ❑ ❑ X❑ Rear 30.0 - 0.49 0.55 Blind Bug ScreenX❑ ❑ F-1 0 ❑ ❑ El F-1 ❑ 0 ❑ ❑ ❑ ❑ ❑ ❑ El 1:1 o❑ ❑ ❑ ❑ ❑ 1:1 El E:1 EJ Run Initiation Time: 12106/00 23.23:28 Run Code: 976145008 EnerAyPro 2.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 10 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Montecito Guest House 12/6/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load: Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency' Location Piping Thermostat Location pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Corrments Central Furnaces 80% AFUE Ducts in Attic 4-2 Setback Ca -4t;= Cooling Equipment Minimum Duct ' Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 11.0 SEER Ducts in Attic 42 Sethack Casits, WATER HEATING SYSTEMS Rated 1 Tank Energy Factl 1 External Water Heater Water Heater Distribution # in Input Cap. or Recoverd Standbyy Tank Insul. System Name Type Type Syst. Btu/hr (gal)- Efficiency Loss (.) R -Value RHEEM 44V40-1 Small Gas' Standard 1 40,000 •39 0-63 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, lis; energy factor For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GUMI'LIANUL b I A I tMtN I This certificate of compliance lists the building features and performance specifications needed to comply withTi1e 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This, certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be builtin multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: QcC. �iG S CO. Name: Joan D. Hacker Title/Firm: - Title/Firm: Insu-form Inc. Address: SD 11 Address: 68255 Corta Road A17 ZZ Cathedral City, CA 92234 Telephone: 57&,r-{ - S6/ 7L Telephone: (760) 324-0216 Lica #,,,L— i'. ._ i h / „ _, Name: Title/Firm: Address: Telephone: signature/sta IEnergyPro 2.1 By EnergySoft User Number: 2655 - Job Number: Page:4 of 10 1 f Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ❑ '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -value. F'§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). ❑ '§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. F-1 § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch. J§118: Insulation specified or installed meets quality standards. Indicate type and form. ] §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ] §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1'. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. pace Conditioning, Water Heating and Plumbing System Measures HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA. ] §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. '§150(m): Ducts and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sectiurns 601 603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m). 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space.have either automatic or readily accessible, manually operated dampers. U §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. hting Measures §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/waft or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at as entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 Iumenstwatt or greater switched at the entrance to the room or one of the altemafive to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. �EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 10 Computer Method Summary (Part 1 of 3) C -2R All Orientations La Quinta Project Address Building Permit # Insu-form Inc. (760) 324-0216 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use.(kBtulsf-yr) Design Facing North Margin Facing East Margin Wall 175 0 081 180 _go Wall 314 0.081 270 90 Roof 449 0.028 a 0 Facing South Margin ❑ ❑ ❑ Facing West Mar in 6.60 -0.98 5.88 -0.26 6.65 -1.03 7.04 -1.42 Space Heating 5.62 ❑❑ Space Cooling 70.65 73.30 -2.66 79.10 -8.45 77.23 -6.59 75.52 -4.88 Domestic Hot Water 41.31 1 32.56 8.75 ❑❑ 32.56 8.75 32.56 8.75 32.56 8.75 1112.46 5.12 117.54 0.03 116.44 1.13 rl 15.13 2.45 Totals 117.58 BUILDING COMPLIES This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence. This plan has been analyzed with identical features in all orientations. GENERAL INFORMATION Conditioned Floor Area: 449 Floor Construction Type: X❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: All Four Orientations Raised Floor Number of Dwelling Units: 1.00 Total Conditioned Volume: 4,939 Number of Stories: 1 Slab Floor Area: 449 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area rasita 449 4939 100 rnnditinnPri SPthark n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Wall 157 0.081 _0 90 Wall 276 0 081 A0 SIL ®❑ R-13 Wall (VV 132x4 16) rasita R-13 Wall (W 13 2x4 16) rasita Wall 175 0 081 180 _go Wall 314 0.081 270 90 Roof 449 0.028 a 0 ❑ ❑ ❑ R-13 Wall fW 13 2x4 16) rasita R-13 Wall (W.132x4 16) rasita R-38 Roof (R 38.2x14.16) Casita ❑❑ H� ❑❑ ❑❑❑ ❑❑ ❑❑ ❑❑ ❑❑ F-1 -1 E] Ll Run Initiation T*mee 12/06/00 23923@28 Run Codev 976145008 EnergyPro 2.1 By Energysoft User Number: 2655 Job Number: Page:6 of 10 Computer Method Summary (Pari: 2 of 3) C -2R Montecito Guest House 12/6/00 Project Title Date FENESTRATION SURFACES LI -Value Act. Glazing Type Location/ # Type Area SHGC Azm. Tilt Comments J_ Window Front (North) 48.0 0 850 0.59 0 -9,n Dnuhle Mtl Tinted Default_ Casita 2 Window Left (East) 30.0 0.500 0.53 90 90 Award Windows Dual Tint Casita 3 Window Left (East) 8.0 0.500 0.53 90 90 Award Windows Dual Tint Casita 4 Window Rear (South) 30.0 0.490 0.55 180 90 Award Windows Dual Tint Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Di:at. Len. Hgt. Dist. Len. Hgt. 1 Drapery 0.68 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 2 Blind 0.47 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 _ 2.0 3 Drapery 0.68 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 _ 2.0 4 Blind 0.47 Bug Screen 0.76 25 4.0 2 0 01 2.0 _ 20 2.1 By EnergySoft User Number: 2655 Job Number: Paae:7 of 10 Computer Method -Summary (Part 3 of 3) C -2R Montecito Guest House 12/6/00 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area. Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2. Insulation Type Length Factor R -Val., Depth Location / Comments Slab Perimeter 95 0.76 0 0 0 Casita HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace,. heat Efficiency and Location Duct Thermostat . Loca=-:ion / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments ' Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Casits Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. ' Cooling Equipment Minimum Duct Type (air conditioner, Efficiency .Location Duct Thermostat Location heat pump, evap. cooling) (SEER) • (attic, etc) R -Value Type 'Comments Split Air Conditioner 11.0 SEER Ducts in Attic 4.2 Sethack Cacit= WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution • # in Input Cap. or Recovery Standbyy R -Value System Name Type Type Syst. (Btu/hr) (al) Efficiency Loss (0) Ext RHEEM 44V40-1 Small Gas Standard 40 000 39 0.63 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS ` Run Initiation Time: 12/06/00 23:23:28 Run Code: 976145008 EnergyPro 2.1 By Energysoft User Number: 2655 Job Number Page 8 of 10 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Montecito Guest House 12/6/00 SYSTEM NAME FLOOR AREA Casita 449 ENGINEERING CHECKS SYSTEM LOAD -771 Number of Systems 1 Heating System Output per System 37,000 Total Output (Btuh) 37,000 Output (Btuh/sgft) 82.4 Cooling System Output per System 23,400 Total Output (Btuh) 23,400 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 52.1 Total Output (sgft/Ton) 230.3 Air System CFM per System 1,215 Airflow (cfm) 1,215 Airflow (cfm/sgft) 2.71 Airflow (cfm/Ton) 623.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF >--111 Outside Air 0 cfm 69.4 of 11.0 / 77.4 of 311� Outside Air 0 cfm 78.4/68.9 of 2.1 69.4 OF 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 12,5971 1-1 57 CARRIER 38CMCO243" 12,908 9,368 37,000 Total Adjusted System Output 12,908 9,368 37,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Dam Temperatures at Time of Heating Peak) 97.8 of Supply Fan Heating Coil 1215 cfm h Return Air Ducts 4 78.4 / 68.9 of 78.4 / 68.9 of 68.5 / 65.6 of -1�7�- .11 Supply Fan Cooling Coil 1215 cfm User Number: 2655 Return Air Ducts Job Number: n Supply Air Ducts 97.2 of ROOMS 70.0 of Supply Air Ducts 69.0 / 65.7 of 63.1`.'0 R.H. ROOMS 78.0 / 68.7 of of 10 'ROOM LOAD SUMMARY PROJECT NAME DATE Montecito Guest House 12/6/00 SYSTEM NAME FLOOR AREA Casita AAQ EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number Page 10 of 10 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE -ATENT CFM SENSIBLE Casita Casita 1 1,183 11,452 1,157 1 183 11,452 1,157 522 15,236 r PAGE TOTAL 1 1,183 11,452 1,157 522 15,236 TOTAL 1 1,183 11,452 1,157 522 15,236 EnergyPro 2.1 By EnergySoft User Number: 2655 Job Number Page 10 of 10