0103-063 (AR)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect. '
License # Lic. Class Exp. Date
,�;��yy✓� t r q �yi
tl�'..TJ f !.l �.Nl•'v+ �+ t i { r�a..t
0..4
1 1 vj f +w`n'4d r 3' fAd•'
Date '� ; Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale*(Sec. 7044, Business & Ptufessiunals Cude).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
() I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Cartier Policy No.
(This section nend not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in. the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions°of Sectiorv3700 of the Labor
Code,.l shill forthwith comply with lthose , r V1
Date: Applicant,'_ -r Applicant's t •`P .i>i �"
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building andSafetf'
for a permit subject to the conditions and restrictions set forth on his
application. i
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicator agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
I Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date. of issuance` of such
permit, or cessation of Work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information 'is
correct. I agree to comply with all+City, and State laws relating to the building
construction, and hereby authorizb. representatives of this City to 'enter upon
the above-mentioned property, for inspection purposes. �.
��j�r1 � 1d �� tri Jd � �'_Ir• +..
Signature (Owner/Agent) "� a ,, * `' "' Date-
' BUILDING PERMIT PERMIT #
DATE VALUATION
LOT ���., TRACT
JOB SITE
APN
ADDRESS
'Cl4f•-�3�.1 :.hk 7.Y,�ellS.tf1..
��J."fi�li••N7*,La
OWNER
CONTRACTOR/DESIGNER/EN &NEER
LA q', TNTA>.
('11k 92,253
f:,'A Q ',1f'm%. CA 92233
tIAF
!rOy�FyPyFRMyITr��pr�y ` p,q 7 �go� 1
d�-t;iflID'b:+J V .L 1, .i� L� .C'ft,�J.�I..9.1f. YN
AD DS a 100
4250 3'P
PLAN CHECK nk, G
.101-000439-318 $1'S7,93a .
s
WNS'3'9$ IC t'IGN PEE
101-000-418-000 3243.00
MMIANICAL 79.9
101.000-421-000 $45,00
ELF,'47WCAL 'fE
101-000-420-01? fl.ii0
P1.1110NOPs3 ) FEE
101-000-419-000 W-09
STRC0.40 MOTION PIZ- � PMID
101-040-241-000 $2.31
ORAD1140 FFR
101-000-423-000 $20.00
D ns" a�" '• ' .. Ct3��`1�t.i��'`1C�.i�•�t.d.��8A:M"PIy.
F104
il. Eff}
MAR 2 7 2001
KE
""OF LA OUINTA
RECEI �'
BY,:^
D FI E
INSPECTOR
is
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
_
Underground Ducts
Forms & Footingsa�
Ducts
_
Slab Grade
Return Air
Steel
Roof Deck
Combustion Air
Exhaust Fans
O.K. to Wrapp
_ _
F.A.U.
Framing
7� f
Compressor
Insulation
_ 3/
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
_
Final
POOLS - SPAS
BLOCKWALL APPROVALS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
_
Electric Final
Waste Lines
l���( (L�,QL
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection�yi/cr
_
//P�/�
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduif
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
Bin # City of La Quinta
Building &r ' Safety Division
Permit # P.O. Box 1504, 78-495 Calle Tarnpic'o
La Quinta, CA 92253 - (619) 777-7012
Building Permit Application and Tracking Sheet
Project Address: Owner's Name:
A. P. Number: Address:
Legal Description:
11
Legal Z&OS —Z City, ST, Zip:
Contractor: ak (--0Kf—,aWJf0-,' Tel -
Address: -7 ZQ -t—L Project Description:
City, ST, Zip:
-N
....... ...
Telephone:
•
X.I.—
State Lic. # City Lic.,&
Arch., Engr., Designer:��Yfa`
Address: 4( - (o2,--5
City, ST, Zip:
X",
Telephone: Jq(- :.x..Construction Type: Mw-e� ccupancy:
Stat eLic.#: C 33OL67 Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: Sq. Ft.: t+ZS # Stories: #Units:
Telephone # of Contact Person: Estimated Value of Project:wt—So,ocio
APPLICANT: DO NOT WRITE BELOW THIS LINE
N Submittal Req'd Ree'd TRACKING PERMIT FEES
Plan Sets ?2 Plan Check submitted Item Amount
Structural CaIcs. Reviewed, ready for corrections Plan Check Deposit
Truss CaIcs. Called Contact Person Plan Check Balance
Title 24 Cales. Plans picked up Constructon K
Grant Deed Plans resubmitted Mechanical
School Fees 2"d Review, ready forcorrections/issue Electrical,
Subcontactor List Called Contact Person Plumbing
Planning Appro4—Plans picked up S;M.I.
Pub. Wks. Appr Plans resubmitted Grading
H.O.A. Approval Review, ready for corrections/issue Develope-- Impact Fee
Called Contact Person A.I.P.P.
Date of permit issue
Total Permit Fees
uQ t G—
f
COMMUNITY DEVELOPMENT
PUBLIC WORKS
FILE COPY
City of La uinta
Developers Project Approval Form
Prior to. the issuance of Building. Permits for the project listed below, the following Departmental
clearances must be obtained. Please return this form to. the Building and Safety Department only
after approval. Contact applicant for resolution of conditions preventing or delaying approval.
Project: GUEST HOUSE (425 S.F.)
.56-040 RIVIERA I
Applicant Contact: BOB EDWARDS (760 775 7933)
Application / Circulation Date: 02/26/2001 JGJ(25
Date -
Community Development Department
Christine di lorio, Planning Manager Date
Public Works Department
eve Speer, Senior Engineer Date:
Building and Safety Department
Greg Butler, Building and Safety Department Manager' Date
Health Department
Date
Fire Department
Date
Schools Fees Paid
Date
Notice:
Document Cannot Be Duplicated
Date 3/27/01
Desert Sands Unified School District
47-950 Dune Palms Road
La Quinta, CA 92253
760-771-8515
CERTIFICATE OF COMPLIANCE
No. 21810 Jurisdiction
Owner NameCharles Smith
No. 80-512 Street Riviera
City La Quinta Zip 92253
Tract #
Lot #
APN # 761-090-048
La Quinta
Permit*
Log h
Study Area
Square Footage 425
Type of Development Residential Addition Nor. of Units
Comments
ion of Casita
a
At the present time, the Desert Sands Unified School District does not collect fees on garag•:s/carports, covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It
has been determined the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of
0.00 X 425 or $ 0.00 the property listed above and that building y
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be,i:su"ed' t
Fees Paid By N/A Telephone ^ . �
Name on the check
By Dr. Doris Wilson,
Superintendent
Fee collected /exempted by Ellen Patino
Signature
Exempt
Check No. N/A
40TICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest he fees or other payment identified
rbove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to a rother public entity authorized to
:ollect them on the District('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
TITLE -24 REPORT
Title 24 Report for:
Smith Residence ` f
-Lot 8 Riviera & Hermitage
La Q6inta, CA 92253
Project Designer:
Robert A. Pitchford
41-625 Eclectic Ste. A-2'.
Palm Desert, CA 92260
(760) 346-2856
49 Report Prepared By: - -
I Tim Scott
�4 -BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
(760) 346-0855
Job Number: CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
,
FOR CON
Date:STRUCTION
1/18/01 DArE 3` ' U f BY IC
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
til EnergyPro 2.1 By EnergySoft Job Number. User Number: 3665
-- v
L
0
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Smith Residence 1/18/01
Project i itie Date
Lot 8 Riviera & Hermitage La Quinta
vroiect Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
Documentation Author i a ep one
Computer Performance 15
Building Permit#
Plan Check I D-affe-
Reldec Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor'Area: 375 ft2
Total Conditioned Slab Area: 375 ft2
Building Type:
(check. one or more)
X Single Family Detached (SFD) ❑ Addition Alone
❑ Single Family Attached (SFA) ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (Northeast) 55 deg Floor Construction Type: FX_1 Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
Component
'Frame
Type
Type
R-38 Roof (R.38.2x14.16)
Wood
R-21 Wall (W.21.2x6.16)
Wood
Slab On Grade
Na
Slab On Grade
Na
FF-NF-51RATION
kssemblyLocation/Commerts
U -Value (attic, garage, typica4 etc.)
0.028 Exterior Roof
0.059 Exterior Wall
0.756 Exposed Slab w/R-0.0 Perimeter Insulation
0.756 Covered Slab w/R-0.0 Perimeter Insulation
Shadina Devices
Type
Orientation Area
Labeled Fenestration
Interior
Exterior
Overhang Side Fins
(SF)
U -Value SHGC�
(roller blind, etc.)
(shadescreen, etc.)
Yes / No
Yes / No
Front
(Northeast)
48.0
0.85 0.88
Drapery
Bug Screen
❑ X❑
❑ 0
Left
(Southeast)
20.0 '
0.87 0.88
Drapery
Bug Screen
❑ X❑
❑ X❑
Rear
(Southwest)
7.0
0.72 0.88
Drapery
Bug Screen
❑ x❑
❑ • X❑
Right
(Northwest)
20.0
0.87 0.88
Drapery
Bug Screen
❑ X❑
❑ X❑
❑ ❑
❑ ❑
1:1 1-1
El El
El El
El El
El El
EI El
❑❑
1:1 El
❑. ❑
❑ El
El 11
1:1 El
❑-❑
❑ ❑
Run Initiation Time: 01/18/01
07:14:55
Run Code: 979830895
EnergyPro 2.1 By Energysoft
User Number: 3665
Job Number:
Page:3 of 29
• 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, lis` energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Stancby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. +
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with'fitle 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Tim Scott
Title/Firm: Robert A. Pitchford Title/Firm: BREEZE AIR CONDITIONING
Address: 41-625 Eclectic Ste. A-2— Address: 75-145 ST. CHARLES PLACE
Palm Desert, CJ)rgZ
Telephone:
Lic. #:
Cy
Name:
Title/Firm:
Address:
. Telephone:
2.1 By EnergySoft
PALM DESERT, CA 92311
Telephon : (760) 346-0855
(date) (signature) (date)
signature stamp (date)
Run Initiation Time: 01/18/01 07:14:55 Run Code: 979830895
User Number: 3665 Job Number: Page:4 of 29
Certificate of Compliance: Residential
(Part 2 of 2) CF -1 R
Smith Residence
Energy Fadi 1
External
1/18/01
• rofec i e
# in Input
Cap.
ate
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
System Name Type Type
Distribution'
(gal)
Efficiency Loss (%)
Heating Equipment
Minimum Type and
Duct or
50
Type (furnace, heat
Efficiency Location
Piping
Thermostat Locaion /
pump, etc.)
(AFUE/HSPF) (ducts, attic, etc.)
R -Value
Type Comments
Split Heat Pump
7.4 HSPF Ducts in Attic
4.2
Setback HVAC -1
Cooling Equipment
Minimum Duct
Type (air conditioner,
Efficiency Location
Duct
Thermostat Location /
heat pump, evap. cooling)
(SEER) (attic, etc.)
R -Value
Type Comments
Split Heat Pump
12.5 SEER Ducts in Attic
4.2
Setback HVAC -1
• 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, lis` energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Stancby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. +
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with'fitle 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Tim Scott
Title/Firm: Robert A. Pitchford Title/Firm: BREEZE AIR CONDITIONING
Address: 41-625 Eclectic Ste. A-2— Address: 75-145 ST. CHARLES PLACE
Palm Desert, CJ)rgZ
Telephone:
Lic. #:
Cy
Name:
Title/Firm:
Address:
. Telephone:
2.1 By EnergySoft
PALM DESERT, CA 92311
Telephon : (760) 346-0855
(date) (signature) (date)
signature stamp (date)
Run Initiation Time: 01/18/01 07:14:55 Run Code: 979830895
User Number: 3665 Job Number: Page:4 of 29
WATER HEATING SYSTEMS
Tank
Energy Fadi 1
External
Rated 1
Water Heater Water Heater Distribution
# in Input
Cap.
or Recovery Standby
Tank Insul.
System Name Type Type
Syst. Btu/hr
(gal)
Efficiency Loss (%)
R -Value
Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp
1 40,000
50
0.53 n/a
12
• 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, lis` energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Stancby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. +
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with'fitle 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Tim Scott
Title/Firm: Robert A. Pitchford Title/Firm: BREEZE AIR CONDITIONING
Address: 41-625 Eclectic Ste. A-2— Address: 75-145 ST. CHARLES PLACE
Palm Desert, CJ)rgZ
Telephone:
Lic. #:
Cy
Name:
Title/Firm:
Address:
. Telephone:
2.1 By EnergySoft
PALM DESERT, CA 92311
Telephon : (760) 346-0855
(date) (signature) (date)
signature stamp (date)
Run Initiation Time: 01/18/01 07:14:55 Run Code: 979830895
User Number: 3665 Job Number: Page:4 of 29
Certificate of Compliance: Residential
(Addendum) CF -1 R
Smith Residence 1/18/01
- Project Title Date
•
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
r—a. — anc oa.cya...Y - a —arca u Ju una. — ... uw-11-11 — Juun naacu.
The DHW System "Standard Gas 50 gal or Less" Energy Factor= 0.530. An EF below 0.58 requires an R-12 External Blanke .
The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only SleepinglAreas.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
r—v 10-4 .
an
Field
Run InIffiation I Ime: un Code: 979830395
EnergyPro 2.1 By.EnergySoft . User Number: 3665 Job Number: Page:5 of 29
0
•
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties
as binding minimum component specifications.
DESCRIPTION Instructions: Check or initial applicable boxes or enter'N/A if not applicable.
DESIGNER
ENFORCEMEN
Building Envelope Measures
® '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
❑ §150(b): Loose fill insulation manufacturers labeled R -value.
"§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls).
❑ '§ 150(d): Minimum R-13 raised floor insulation in woad framed floors.
❑ § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch.
® §118: Insulation specified or installed meets quality standards. Indicate type and form.
®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ,
2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
® §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
® §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.
® §150(i): Setback thermostat on all applicable heating and/or cooling systems.
® §1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined internal/external insulation, piping between heat source and tank insulated.
3. Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R4 or greater), buried or exposed
piping in recirculating sections of hot water systems, cooling system piping below 55 deg F.
® .§150(m): Ducts and Fans
1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBG 1997 UMC sections
601 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shat, be
sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181,
UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m).
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated
dampers.
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating.
2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light.
Lighting Measures
® §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at am
entrance to the kitchen.
® 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumerrs/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed
ceiling are IC (insulation cover) approved.
IEnergyPro 2.1 rsy Energyson user NUmoer. 3665 Job Number: Page:6 of 29 1
Computer Method Summary (Part 1 of 3) C -2R
Smith Residence 1/18/01
WroJec i e a e
Lot 8 Riviera & Hermitage La Quinta
vroject Aaaress
BREEZE AIR CONDITIONING (760) 346-0855
ocumen ion u or I a ep one
Computer Performance 15
-Comp lance e o -ac age or ompu er Ulm—a ee -.-
Building
.-
w ing Permit#
Plan (TeclUDate
Field Jec a e
Source Energy Use Standard Proposed Compliance
(kBtu/sf-yr) Design Design Margin
Space Heating
5.55
9.85
-4.30
Space Cooling
73.21
51.58
21.63
Domestic Hot Water
48.50
46.83
1.67
Totals2 2
108.27
0
131,1111-IJINU
COMPLIES
GENERAL INFORMATION
Conditioned Floor Area:
375
Floor Construction Type:
M. Slab Floor
Building Type:
Single Fam Detached
E] Raised Floor
Building Front Orientation:
(Northeast) 55 deg
Number of Dwelling Units:
1.00
Total Conditioned Volume:
3,750
Number of Stories:
1
Slab Floor Area:
375
13UILDING ZONE INFORMATION
# of_
Thermostat Vent
Zone Name
Floor Area
Volume
Units Zone Type
Type Hgt. Area
HVAC -1
375
3,750
1.00 Sleeping
-
SleepingStat 2 n/a
LJ
OPAQUE SURFACES
Type Area U -Val
Act.
Azm. Tilt
Solar
Gains
Y / N Form 3 Reference
Location / Comments
Computer Method Summary
Drapery
0.68 Bug Screen
(Part 2 of 3) C -2R
Smith Residence
Drapery
0.68 Bug Screen
_ _
0.76
1/18/01
O'Prol/ect Tit e
0.68 Bug Screen
_ _
0.76
Date
Drapery
LI -Value
0.76
Act.
Glazing Type
Location/
# Type Area
SHGC
Azm.
Tilt
Comments
1 Window Front (Northeast) 48.0 0.850
0.88
55
90 Double Mtl Uncoated Default
Casita Bedroom
2 Window Left (Southeast) 20.0 0.870
0.88
145
90 Double Mtl Uncoated Default
Casita Bedroom
3 Window Rear (Southwest) 2.3 0.720
0.88
235
90 Double Mtl Uncoated Default
Casita Bedroom
4 Window Rear (Southwest) 2.3 0.720
0.88
• 235
90 Double Mtl Uncoated Default
Casita Bedroom
5 Window Rear (Southwest) 2.3 0.720
0.88
235
90 Double Mtl Uncoated Default
Casita Bedroom
6 Window Right (Northwest) 20.0 0.870
0.88
325
90 Double Mtl Uncoated Default
Casita Bedroom
INTERIOR AND EXTERIOR SHADING
Window Overhang Left Fin Right Fin
# Interior Shade Type SHGC Exterior Shade Type
SHGC
gid- en. Hgt. xt. x .stlJ
Len. FITist6' . Len. Flgt.
2
Drapery
0.68 Bug Screen
0.76
3
Drapery
0.68 Bug Screen
_ _
0.76
4
Drapery
0.68 Bug Screen
_ _
0.76
5
Drapery
0.68 Bug Screen
0.76
s
Drapery
0.68 Bug Screen
_
0.76
Run Initiation Time: 01/18/01 07:14:55 Run Code: 979830895
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page:8 of 29
'r
Computer Method Summary
(Part 3 of 3) C -2R
Smith Residence
1/18/01
•ro/ec i e
Date -
THERMAL MASS FOR HIGH MASS DESIGN
Area
Thick. Heat
Inside
Location
Type (sf)
(in.) Cap. Cond. Form.3 Reference
R -Val.
Comments
PERIMETER LOSSES
F2 Insulation
Type Length
Factor R -Val: Depth Location /Comments
Slab Perimeter 40
0.76 0.0 0 Casita Bedroom
Slab Perimeter 42
0.76 0.0 0 Casita Bedroom
HVAC SYSTEMS
Heating Equipment
Minimum Distribution Type
Type (furnace, heat
Efficiency and Location Duct
Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value
Type
Comments
Split Heat Pump
7.4 HSPF Ducts in Attic 4.2
Setback
HVA --1
Hydronic Piping Pipe
Pipe Insul.
System Name Length
Diameter Thick.
Cooling Equipment
Minimum Duct
Type (air conditioner,
Efficiency Location Duct
Thermostat.
Location /
heat pump, evap. cooling)
(SEER) (attic, etc,) R -Value
Type
Comments
Split Heat Pump
12.5 SEER Ducts in Attic 4.2
Setback
HV<.0-1
WATER HEATING SYSTEMS Ratedl Tank Energy Fact 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp 1 40,000 50 AE3 nla 12
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 01/18/01 07:14:55 Run Code: 979830895
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Pagel of 29
Computer Method Summary (Addendum) C2 -R
Smith Residence 1/18/01
' Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. Tl -,,,e local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
------....._
-_-., ..-, .... F. . . . . .... ... ....... Plan I Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanke .
The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF 6R
•
•
Run InitiationTime: un Code:.
EnergyPro 2.1 , By EnergySoft , User Number: 3665 Job.Number:. Page: 10 of 29
an
Field
Run InitiationTime: un Code:.
EnergyPro 2.1 , By EnergySoft , User Number: 3665 Job.Number:. Page: 10 of 29
INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R
Sia Address erml urr, ber
An installation certificate is required to be posted at the building site or made available for all appropriate inspections.
(The information provided on this form is required; however, use of this form to provide the infcxmation is optional.)
After completion of final inspection, a copy must be provided to the building department (upon -equest) and the
building owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heating Equipment
Equip. # of Efficiency, Duct Duct or Heating Heat' 119
Type (pkg., CEC Certified Mfr Name. Identical (AFUE, etc.)) Location Piping Load Capacity
heat pump) & Model Number Systems [>= CF -1 R Va[ue] (attic, etc.) R -Value (Btu/hr) (Btu/hr)
Cooling Equipment
Equip. CEC Certified Compressor # of Efficiency, Duct Cooling Cooling
Type (pkg., Unit Mfr Name & Identical (SEER, etc.) Location Duct or Load Capacity
heat pump) Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr)
T >= reads Greater Than or Equal to.
I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent
to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the
Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate
requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature; Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
WATER HEATING SYSTEMS:
CEC Certified Distribution If Recir- # of Rated2 Tank Ef•i2 2 External
Heater Mfr Name Type(Std, culation, Identical Input (kW Volume ciencLr Standb Insulation
Type & Model Number Point -of -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (e/ j R -Value
2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input.
For instantaneous gas water heaters, list Recovery Efficiency and Rated Input.
3 R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58.
Faucets & Shower Heads:
All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111
I, the undersigned, verify*that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to
or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy
Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for
manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
COPY TO: Building Department OR General Contractor (Co. Name) OR Owner
HERS Provider (if applicable)
Building Owner at Occupancy
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 11 of 29
INSTALLATION CERTIFICATE (Part 12 of 7) CF -6R
Sim . dress -Permit Number
FENESTRATION / GLAZING:
Product U- Product Interior or
Value r SHGC1 Exteror Shading
(=<CF -1 R (=< CF -1 R # of Quantity Square Device or Comments/
Manufacturer/Brand Name value)? valuey Panes (Optional) Feet Overhang Special Features
GROUP LIKE PRODUCTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
1. Manufactured Fenestration products use the values from the product label. Field fabricatedfenestration products use the default values from Section 1.16 of the Energy Efficiency Standards.
• 2. Installed Ll -value must be less than or equal to values from CF -1R. Installed SHGC must be less than or equal to values from CF -1 R, ora shading devi :a (interior, exterior or overhang) is
installed as specified on the CF -1 R. Alternatively, installed weighted average U -values for the total fenestration area are less than or equal to values from -,F-IR.
I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2)
is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance (Form CF -1 R) .
submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the 1product meets or exceeds
the appropriate requirements for manufactured devices (from Part 6), where applicable.
tem #s - Signature, atenes offing Subcontractor( o. Name),
(if applicable) OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Item #s Signature, Date Installing Subcontractor (Co. Name)
(if applicable) OR General Contractor (Co. Name) OR Owner
OR Window Distributor
Item #s Signature, Date Installing Subcontractor ?Co. Name)
(if applicable) OR General Contractor (Co. Name) OR Owner
OR Window Distributor
• COPY TO: Building Department .
HERS Provider (if applicable)
Building Owner at Occupancy
Energy Pro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 12 of 29
INSTALLATION CERTIFICATE (Part 3 of 7) CF -6R
• Site Address _P_er_miFl4`uffil5er
DUCT DIAGNOSTICS
This buiding obtained compliance credit for:. ❑ Duct sealing - ❑ Duct Area Reduction
❑ ACCA Manual D design and installation
CREDIT FOR REDUCED DUCT SURFACE ACCA Design
AREA OR LOCATION
Duct Location* Exterior Measured ❑ Duct Design on Plans
Surface Area Exterior Surface
(CFA R) Area ❑ Installed duct diameters match plans
❑ Attic
❑ Crawlspace
❑ Basement
❑ Other
Total
❑ TXV installed
❑ Access to TXV valve (if installed)
❑ No TXV, Fan air flow (CFM) -
❑ Duct Leakage Measured
❑ Measured leakage (CFM)
HVAC fan air flow (CFM)
(measured or calculated.as
*Ignore ducts in ❑-
conditioned space. CFM = 0.7 x Afloor for CZ 8 through 15
Only a check is ❑CFM = 0.5 x Afloor for CZ 1 through.? & 16
required for location or, it the equipment size is known, the larger :)f 1 or 2.
credit.
1. ❑ CFM = 400 x Cooling Capacity in Tcns or
~ 2. ❑ CFM = 21.7 x Heating Capacity in T.iousands of Btu per hour)
Leakage divided by HVAC Fan air flow (must be =< 0.06)
For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed:
*❑ Duct Fan Pressurization at rough - in measured leakage CFM CHECK AFTER FINISHING WALL:
❑ Pressure Pan Test ❑ House pressuezation test ❑ Visual Inspection of Duct Connections
Provide Follow-up Test Results or Inspection Results on a Separate Page
❑ This certifies that the ducts surface area and duct locations were verified.
When compliance credit is claimed for duct surface area reducitons and duct location improvements beyond those covered by default
assumptions, builder employees or subcontractors shall certify that they have verified that the duct surface a -ea and Locations match those
on the plans and shall indicate the duct surface area in each duct location on the.CF6R.
❑ This is to certify -that the above diagnostic test results and the work I performed associated with the tBst(s) is in conformance with
the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requiremerts for compliance credit.]
Tests Signature, Date Installing Subcontractor o.ame
Performed OR General Contractor (Co. Name) OR Owner
• COPY TO:. Building Department
HERS Provider (if applicable)
Building Owner at Occupancy,
EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: Page: 13 of 29
M
INSTALLATION CERTIFICATE (Part I- of 1) -CF-6R
• Site Address Permit Number
j
BUILDING ENVELOPE LEAKAGE DIAGNOSTIC*S
This buiding obtained compliance credit for: Envelope sealing using diagnostic testinc (CF -1 R)
Needed for Compliance
(from CF -1 R)
-Building Envelope Leakage (CFM @ 50 Pa)
-Leakage level equivalent to an SLA of 3.0 from CF -1 R
-Minimum Building Leakage equivalent to an SLA of 1.5
from CF -1R (CFM @ 50 Pa)
Measured Blowerdoor Test
Results
❑ Yes ❑ No . Is design infiltration less than the SLA 3.0 equivalant (from CF -1 R)?
Yes No. Is mechanical ventilation installed? (Required if design is less than 3.0 SLA)
Yes No Is measured leakage (without fans operating) less than minimum in the above Table (1.5 SIA from CF -1 R)?
❑ Yes 0 No Is mechanical supply ventilation installed to assure house pressure does not go below minus 5 Pascal relative to
outside ambient with all exhaust fans operating?
Mechanical Ventilation- Fill in Table if mechanical ventilation is installed
Used for Compliance
(from CF -1 R)
ContinuousMechanical Ventilation (CFNI6
-Continuous Mechanical Supply Ventilation
(CFM) Required to maintain -5 Pa if building
envelope leakage is less than minimum (see
above)
-Total Power Consumption of Continuous
Mechanical Ventilation (Watts) 2
❑ This certifies that the building leakage was verified.
Measured
Actual
When compliancecredit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall
certify that they have verified that the building leakage level matches that used for compliance on the CF -6R and shall document the
infiltration levels required for compliance and the tested infiltration values on the CF -6R..
ElThis is to certify that the above diagnostic test results and the work I performed associated with the test(s) i'-� in conformance with
the requirements -for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder
employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for oompliance credit.]
Tests Signature, Date Installing Subcontractor o.Name)
Performed - OR General Contractor (Co. Name) OF: Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
1. When mechanical ventilation is required, CFM less than 0.047 CFM per square foot of conditioned floor area indicates failure to achieve compliance
• 2. As determined from label on fan or manufacturers literature.
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 14 of 29
INSTALLATION CERTIFICATE (Part 5 of 7) CF -6R
0 Site Address Permit Number
The following is an explanation of many of the input values required on this form:.
HVAC SYSTEMS
Heating Equipment Type must be one of the following:
Furnace:
Gas (including Liquefied Petroleum Gases) or oil -fired central furnace & space heater
Boiler:
Gas or oil -fired boiler
PckgHeatPump:
Packaged central heat pump
SplitHeatPump:
Split central heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (>=65,000 Btu/hr output)
Electric:
Electric resistance heating (fixed HSPF = 3.413); radiant electric resistance
(fixed HSPF = 3.55)
CombinedHydro:
Reference water heater under water heating systems below
-CEC Certified Manufacturer Make & Model Number from applicable Commission approved appl;ance directory.
-V of Identical Systems" is for those systems with the same efficiency, duct location, duct R -Value and capacity.
-Efficiency from applicable Commission certified appliance directory.
-Duct Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none.
-Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data.
-Heating/Cooling Load refer to Commission approved load calculation procedure.
-Heating/Cooling Equipment Capacity from the applicable Commission certified appliance directory. Note: location
• elevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's literature).
Cooling Equipment Type must be one of the following:
SplitAirCond:
Split system air conditioner
PckgAirCond:
Packaged air conditioner
SplitHeatPump:
Split system heat pump
PckgHeatPump:
Packaged heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (>=65,000 Btu/hr output). Substitute EER for
SEER when SEER is not available.
RoomAirCond:
Room air conditioner. Minimum SEER varies*
LrgPkgAirCond:
Large packaged air conditioner (>=65,000 Btu/hr output). Substitute EER for
SEER when SEER is not available.
EvapDirect:
Direct evaporative cooling system. For compliance calculation
purposes, fixed values:
SEER = 11.0; duct location = attic;
duct insulation R -value = 4.2
Evapindirect:
Indirect evaporative cooling system. For compliance calculation
purposes, fixed values:
SEER = 13.0; duct location = attic;
duct insulation R -value = 4.2
*Refer to California Energy Commission (CEC) publication Appliance Efficiency Regulations, P400-92-029
EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: Page: 15 of 29
INSTALLATION CERTIFICATE (Part 6 of 7) CF -6R
Slte Address Hermit Number
The following is an explanation of many of the input values required on this form:
WATER HEATING SYSTEMS
Distribution Systems: Refer to Residential Manual for more details.
Standard:
Standard -Supply prssure based system, no pumps
Pipe Insulation:
Pipe Insulation on all 3/4 -inch pipes
POU/HWR:
Point of Use/Hot Water Recovery System
Recirc/NoControl:
Recirculation loop with no controls
Recirc/Timer:
Recirculation loop with a timer
Recirc/Temp:
Recirculation loop with temperature control
Recirc/Time + Temp:
Recirculation loop with a timer and temperature control
Recirc/Demand:
Recirculation loop with demand control
Water Heater Type
Windows, sliding glass doors, french doors, skylights, garden windows, and
Information Needed
any door with more than one square foot of glass
Operator Type;
Energy Factor
Recovery Efficiency
Standby Loss
Rated Input
Storage Gas, Oil or Electric
Yes
No
No
No
Heat Pump
Yes
No
No
No
Instantaneous Gas
No
Yes
No
No
Instantaneous Electric
Yes
No
No
No
Large Storage Gas
No
Yes
Yes
Yes
Indirect Gas (Boiler)
No
Yes (AFUE)
No
Yes
•
FENESTRATION / GLAZING
Fenestration:
Windows, sliding glass doors, french doors, skylights, garden windows, and
any door with more than one square foot of glass
Operator Type;
Slider, hinged, fixed
U -Value:
Installed U -Value must be less than or equal to value from CF -1 R
OR
Installed weighted average U -Value for the total fenestration area
is less than or equal to value from CF -1 R
SHGC:
Installed SHGC must be less than or equal to value from CF -1R
OR
Installed SHGC for the total fenestration area is less than or equal to value
from CF -1R
OR
An interior shading device, overhang, or exterior shading device is installed
consistent with the CF -1 R
S hadingDevice:
Include when the building complied using an interior shading device: blinds,
opaque roller shades, blinds (do not list draperies), an exterior shading
device: woven sunscreen, louvered sunscreen, low sun�angle surscreen,
roll -down awning, roll -down blinds or slats (do not list bug screen)„ or an
overhang (include depth in feet)
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 29
INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R
bite Address Hermit Number
The following is an explanation of many of the input values required on the Diagnostic portion ,of this form (page 3
of 6):
TYPE OF CREDIT
Refer to Residential Manual Chapters 4 and 5 for more details:,
Reduced Duct Surface
` Area:
Calculated as the outside area of the duct. Areas must be measured and
verified by HERS rater.
Improved Duct Location:
Supply duct located in. other than attic, as verified by locaJon of -registers
(does not require HERS rater verification).
Catastrophic Leakage:
Pressure pan test reading must be less than 1.5 Pascal a- a house pressure
of 25 Pascal.
• TXV:
Access cover required to facilitate verification.
Infiltration Reduction-
Infiltration is measured without mechanical ventilation operating.
Mechanical ventilation is required for very tight house construction when
credits for infiltration reduction using diagnostic testing are.beng used for
achieving compliance. These very tight houses are defined as those with
SLA of less than 1.5. The compliance documentation (CF -1 R) will contain
the measured CFM target value from a blower door test a-: 50 Pascal
pressure difference that represents this SLA of 1:5. Mecl-anical ventilation
is also required if the builder chooses to design the building touse
mechanical ventilation and claims a credit for infiltration below an SLA of
3.0. The compliance documentation (CF -1 R) will contain :he measured
CFM target value that represents this 3.0 SLA. If the builder claims credit
in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and
the actual measured SLA is 1.5 or greater, then mechanical ventilation is
not required. If the SLA in this case were below 1.5, alien mitigation (such
as'mechanical ventilation) would be required.
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 17 of 29
0
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Smith Residence 1/18/01
SYSTEM NAME FLOOR AREA
HVAC -1 375
26.0 of
Outside
0 cfm
69.0 OF
11.0 / 77.4 OF
Outside
0 cfm
74.9/59.6 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK COIL HTG. PEAK
CFM I Sensible Latent I I CFM I Sensible
487
12,059
1,448 709
12,507
0
603
625
0
0
0
0
0 0
0
0
0
603
625
13,265 1,448 13,758
LENNOX HP26-018-7P 16,057 0 11,838
Total Adjusted System Output 16,057 0 11,838
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Ang 2 pm Jan 12 am
69.0 of 69.0 of 87.4 of
Supply Fan Heating Coil
600 cfm
m ie
74.9 / 59.6 of 74.9 / 59.6 OF . 50.0 / 48.7 OF
Supply Fan Cooling Coil
600 cfm
k Return Air Ducts q
Supply Air Ducts
86.5 of
ROOMS
70.0 of
Supply Air Ducts
50.9 / 49.1 OF
41.4% R. H. ROOMS
74.0 / 59.2 of
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 18 of 29
0
•
0
ROOM LOAD SUMMARY
PROJECT NAME
Smith Residence
DATE
1/18/01
SYSTEM AME
HVAC -1
FLOOR AREA
375
IROOM LOAD SUMMARY
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Casita Bedroom
Bedroom
1
487
12,059
1,448
487
12,059
1,448
709
12,507
PAGE TOTAL 487 12,059 1,448 709 12,507
TOTAL 487 12,059 1,448 709 12,507
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page:19 of 29
ROOM HEATING PEAK LOADS
Project Title
Smith Residence
Date
11/18/01
Room Information Design Conditions
Room Name Bedroom
Time of Peak Jan 12 am
Floor Area 375
Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70 OF
729.0
Conduction
Oran 1 I_Valno Ar 0e Riu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,559
Infiltration: 1.00 x 1.072 x 375 x 10.00 x 1.00 / 6G1 x 0 = 2 gqg
c e u eAir Sensible Area Ceiling Heigh ACHJ pT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 12,507
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 20 of 29
375.0
X
X
X
X
X
x
X
x
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0280
X
X
X
X
X
x
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
462
729.0
0.0592
44.0
1,899
48.0
0.8500
44.0
1,795
40.0
0.8700
44.0
1,531
7.0
0.7200
44.0
222
perimeter 82.0
44.5
3,649
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,559
Infiltration: 1.00 x 1.072 x 375 x 10.00 x 1.00 / 6G1 x 0 = 2 gqg
c e u eAir Sensible Area Ceiling Heigh ACHJ pT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 12,507
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 20 of 29
10
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Smith Residence 1/18/01
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Bedroom
740F
112°F
380F
Conduction Area U -Value DETD 1 Btu/hr
X
(Northeast)
55.0
=
578
X
4
34.6
=
1,493
X
(Northwest)
38.0
=
1,550
X
939
38.0
=
1,322
X
0.757
38.0
=
192
X
X
X
X
1. Design Equivalent Temperature Difference (DETD) Page Total 5,136
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF , SC Btu/hr
1
(Northeast)
2
(Southeast)
3
(Southwest)
4
(Southwest)
5
(Southwest)
6
(Northwest)
1
20.0
62)
0.757
939
0.0
1
2.3
0.0
X
X
x
X
X
x
X
X
X
X
1
+
+
+
+
+
+
+
+
+
+
48.0
X
X
X
X
X
X
X
X
X
X
48)
X
x
x
X
X
X
)X
)x'
)X
)X
0.757
=
=
=
=
=
=
=
=
=
1,744
0.0
1
20.0
62)
0.757
939
0.0
1
2.3
62)
0.757
110
0.0
1
2.3
62)
0.757
110
0.0
1
2.3
62)
0.757
110
0.0
1
20.0
48)
0.757
727
.
Sched. Page Total 3,73s
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 375 X 0.000 Watts/sgft x 3.41 Btuh[Watt = 0
Occupants 1.00 X 375 X 255 Btuh/OCC. / 250 sgfttocc. = 382
Receptacle 1.00 X 375 X 0.200 Watts/sqft x 3.413 Btuh/Watt = 256
Process 1.00 X 375 X 0.000 Watts/sgft x 3.412 Btuh/Watt = 0
Infiltration: 1.00 x 1.072 x 375 x 10.00 x 1.00 / 60] 38 = 2,546
ceue r ens a Area a ng e g Q
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,059
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 375 X 225 Btuh/OCC. / 250 sgft/bcc. = 338
Receptacle 1.00 X 375 X 0.000 Watts/sgft x 1 3.41 Btuh/Watt = 0
Process 1.00 X 375 X 0.000 Watts/sqft X 1 3.41 Btuh/Watt = 0
Infiltration: [ 1.00 x 4,806 X 37 x 10.00 x 1.00 / 60] 1 0.00370
ceuer Latent Area Ceiiing meig Qyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,448
EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: Page: 21 of 29
i
S
LISTED
o COILS — BLOWER COIL UNITS
MULTI -POSITION
BLOWER COIL UNITS Bulletin#210106
*12,600 to 60,000 Btuh (3.7 to 17.6 kW) Cooling Capacity November 1995
*11,500 to 58,000 Btuh (3.4 to 17.0 kW) Heat Pump Heating Capacity
2.5 to 30.0 kW Optional Electric Heat
*ARI Standard 210/240 Ratings With Matching Outdoor Unit
Applications
U i • 1-1/2 to 5 ton (5.3 to 17.6 Wvl) nominal sizes.
• Multi -position (up -flow, . down -flow or horizontal)
Lapplications.
C ® SO • Applicable to :expansion valve systems in cooling
IORID tASSOUAUr2 REGISTERED applications and check and expansion valves stems in
WORD) CIASS OUAUTY PP P Y
LISTED heat pump applications.
• Wide range check and expa-ision valve factory installed.
• See Condensing Unit bulle-ins in section Cooling Units —
�..�_�; Condensing Units for coolirllg capacjties.
} " "� • See Heat Pump Outdoor (Unit Bulletins in section Heat
Pumps — Matched Remote Systems for cooling and
heating capacities.
• Optional field installed electric heaters available in
r several sizes for additive heating capacity.
:tea • Filter furnished.
"?. • Optional additive base available for models with electric heat
installed in down -flow position on combustible floors.
CB30M Warranty
7� Up -flow Position • All covered components — five years (residential
(With Optional Electric Heat) applications), one year (non-residential applications).
Completely Tested and Approvad
• Tested with matching condensing and heat pump units in
r the Lennox Research Laboratory environmental test
room in accordance with ARI Standard 210/240-89.
• Optional electric heaters -ated• in accordance with U.S.
Department of Energy (DCE) .test procedures and Federal
Trade Commission (FTC) labeling regulations.
• Blower performance da_a according to unit tests
conducted in Lennox air test chamber.
• Blower -coil. units are U.L. Listed to U.S. and Canadian
safety standards and comaonents within are bonded for
grounding to meet safety standards for servicing required
,. ;,• by CEC and NEC.
• Units developed in acco•dance with ISO 9002 quality
standards.
Cabinet
• Constructed of.heavy gauge galvanized steel.
:5L ' E • Completely insulated with thick fiberglass insulation.
• Pre -painted steel cabinets have mildly textured enamel
finish with primer coat on unpainted side of all panels.
tr • Units are shipped in one piece but may be disassembled into
c two separate sections for ease of installation in tight
applications. See dimension drawings.
• Thick rubber gasket between sections provides air tight seal.
• No external screw heads on sides of cabinet for tight
C830M installatigns without damage to walls or woodwork.
• Removable panels provide complete service access.
Horizontal Left Hand Position . Electrical inlets provided in sides and top of cabinet. See
(With Optional Electric Heat) dimension drawings for locations.
Typical Applications
With Optional Electronic Air CIJ:aner
Q The maple leaf symbol in this bulletin denotes Canadian only usage where applicable Q1995 Lennox Industries Inc.
NOTE — Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without iotice and without incurring liability."
;r
•
SPECIFICATIONS
-I
Model Number
C630M-21/26}CB30M-31
CB30M-41
CB3)M-46 CB30M-51 CB30M-66
Net face area - ft.z (mz)
3.11 (0.29)
3.56 (0.33)
4.44 (0.41)
4.44.(0.41) 5.0 (0.46) 5.0 (0.46)
Tube outside diameter - in: (mm)
3/8(9.5)
3/8 (9.5)
3/8(9.5)
3/8(9.5) 3/8(9.5) 3/8(9.5)
Evaporator
Number of rows
2
2
2
3 3 3
Coil
Fins per inch (fins per m)
14 (551)
14 (551)
14 (551)
12-472) 12 (472) 12 (472)
Su t. (vapor) line conn. - in. (mm) sweat
5/806)
3/4(19)
3/4(19)
7/8 22.2) 7/8(22.21 .1-1/8(28)
Liquid line conn. - in. (mm) sweat
3/8(9.5)
3/8 (9.5)
3/8 (9:5)
3/8(9.5) 3/8(9.5) 3/8(9.5)
Condensate drain connection (fpt) - in. (mm)
(2) 3/4 (19)
(2) 3/4 (19)
(2) 3/4 (19)
(2) 14 (19) (2) 3/4 (19) (2) 314 (19)
Nominal cooling capacity - tons (kW)
1-5 - 2
(5.3-7.0)
2.5 (8.8)
3(10.6)
3.5 :6.3) 4(14.1) 5(17.6)
Refrigerant
HCFC -22
Blower wheel nominal diameter x width - in. (mm)
10 x 7
10 x 8
11 x8
11 x 8
11-1/2 x 9
12 x 9
(254 x 178)
(254 x 203)
(279 x 203)
(279 z 203)
'(292 x 229)
(305 x 229)
Blower motor output - hp (W)
1/5(149)
1/3(249)
1/3(249)
1/3 Q49)
1/3 (249)
1/2(373)
in.
(1)15x20x1
(1)20x20x1
(1)20x24x1
ttNumber and size of filters
mm
(1) 381x508x25
(1) 508 x 508 x 25
(1) 508 x 610 x 25
Electrical characteristics (60hz)
208/230v-1ph
208/230v-1ph
**460v
208/23[+v-1ph
208/230v-1 ph
**460v - 3 ph
- 3 ph
***575v - 3 ph
Shipping weight - lbs. (kg) 1 package
136 (62)
157 (71)
177.(80)
181 .82)
206 (93)
206 (93)
• Optional Accessories (Must Be Ordered Extra)
Side Return Unit Stand
Catalog number
45K31
450.32
(Up -Flow Only)
Ship. wt. - lbs. (kg)
5 (2)
6 C3)
Wall Hanging Bracket Kit - Shipping weight - lbs. (kg)
45K30 - 3 (1) (Up -Flow Only)
Down -Flow Combustible Base - Ship. wt. - lbs. (kg)
34,172 - 8 (4)
34,173 - 8 (4)
*Output - Btuh (kW)
9,500 (2.8)
10,000 (2.9)
- - - -
- - - -
- - - -
_ _ _ ..
ECB29-2.5
tA.F.U.E.
100%
100%
----
----
----
____
ECB29-5,
*Output - Btuh (kW1
18,000 (5.3)
18,500 (5.4)
18,500 (5.4)
19,000 (5.6)
19,000 (5.6)
- - - -
ECB29-5CB
tA.F.U.E.
100%
100/
.100/
100!0
.100/
ECB29-8,.
*Output - Btuh (kW►
28,000 (8.2)
28,500 (8.4)
28,500 (8.4)
29,000 (8.5)
29,000 (8.5)
30,500 (8.9)
ECB29-8CB
tA.F.U.E.
100%
100%
100%
100%
100%
100%
ECB29-10,
*Output - Btuh (kW)
35,000 (10.3)
35,500 (10.4)
35,500 (10.4)
36,000 110.5)
36,000 (10.5)
37,000 (10.8)
ECB29-10CB
tA.F.U.E.
100%
100%
100%
100%
100%
100%
Electric
Heat
*Output - Btuh (kW)
- - - -
44,000 (12.9)
44,000 (12.9)
44,500 0110)
44,500 (13.0)
45,500 (13.3)
Capacity
EC1329-12.5CB
tA.F.U.E.
- - - -
100%
100%
100 A
100%100%
(1 phase)
*Output -7Btuh (kW)
- - - -
52,500 (15.4)
52,500 (15.4)
53,000 (05.5)
53,000 (15.5)
54,000 (15.8)
ECB29-15[6
tA.F.U.E.
- - - -
100%
100%
100''
100%
100%
*Output - Btuh (kW)
-
- - - -
- - - -
69,500 (20.4)
70,000 (20.5)
70,000 (20.5)
71,500 (20.9)
ECB29-20[6
tA.F.U.E.
- - - -
- - - -
100%
10001.3
100%
100%
*Output - Btuh (M
- - - -
- - - -
- - - -
87,00 (25.5)
88,500 (25.9)
EC829-25[6
tA.F.U.E.
100%
100%
*Output - Btuh (kWl
- - - -
- - - -
- - - -
105,500 (30.9)
EC829-3006
tA.F.U.E.
- - - -
- - -
----
----
100%
w �, �y �a�eu o.. v.�. we cess proceaures ana according to r i c iabeung regulations.
ttDisposable frame type filter.
*Includes additional blower motor heat capacity.
**Blower motor is 460v - 1 phase. Optional electric heat is 460v - 3 phase.
-Blower motor is 460v single phase. 575v electric heaters are shipped with step-down transformer for use with 460v units (CE,30M-51 & C830M-65 models only). i
CB30M / Page 3 ►
DIMENSIONS
CB30M UP -FLOW POSITION
SUPPLY
AIR DETAIL OF PIPING PLATE
3/d OPENING; "�---�"'--- ---
1191
SUCTION UNE 4.3/8
(1111 CONDENSATE
�4 3/4 I LIQUID DRAINS 12)
1791 11-Il16 (2D81) 1191 I UNE IHorizontall
+
(51) O
O /
Mode
No.
.
830M-31
IDRAINS
5.3/8
(137) + +
CONDENSATE
(2)
(Up -Flow and
Down -flow)
LIU
-LINE VOLTAGE 'LOW VOLTAGE
INLETS INLETS
Pol 0
1
ITop and Left Side) (Top and
Right Side)
1.3/4 11
inch
TOP VIEW
1 — — 1641 3.1/2 (891 — —
mm
inch
mm
A
5/8
1149
49-1/4
1251
51
1295
52.1/2
116) ,
u nunnuanw
1486
B
16-1/4
413
21-1/4
540
21-1/4
540
21-1/4
546
21-1/4
54J0
C
20-5/8
524
20-5/8
AIR FLOW I
22-5/8
575
NAL
ELECTRIC
; (BLOWER) I
24-5/8
625
I
14-3/4
375
HEAT
�\- /�/
19-3/4
502
—
502
19-3/4
Installed)
19
483
19
Mir
21
533
21
533
t I
584
F
SI
COf. I
20
Mode
No.
C830 lY
830M-31
C830M-4T
C830M-46
CB30M-65
inch
mm
inch
mm
inch
mm
inch
mm
inch
mm
A
45-1/4
1149
49-1/4
1251
51
1295
52.1/2
1334
58-1/2
1486
B
16-1/4
413
21-1/4
540
21-1/4
540
21-1/4
546
21-1/4
54J0
C
20-5/8
524
20-5/8
524
22-5/8
575
22.5/8
575
24-5/8
625
D
14-3/4
375
19-3/4
502
19-3/4
502
19-3/4
502
19-3/4
502
E
19
483
19
483
21
533
21
533
23
584
F
15
351
20
508
20
508
20
508
20
508
GB
24-5/8
625
24-5/8
625
26-3/8
670
27-7/8
708
27-7/8
708
H
2O-5/8
524
24-5/8
625
24-5/8
625
24-5/8
625
30-5/8
778
PIPING UCTION
H LINE \
LIQUID` I I
— — LINE _ ^ = � •
fetI. FILTER FILTER
Return Air ACCESS
F 1
s/e FRONT VIEW 5/e 1251
Its) (16)
Return Air
— E. f� 5/8
SIDE VIEW (161
CB30M DOWN -FLOW
5/8
061
Model
No.
C830M-21/26
CB30M-31
C83OM-41
CB30M-46
CB30M-51
CB30M-65
inch
mm
inch
mm
inch
mm
inch
mm
inch
mm
A
45-1/4
1149
49-1/4-1251
51
1295
52-1/2
1334
58-1/2
1486
B
16-1/4
413
21-1/4
540
21-1/4
540
21-1/4
540
21-1/4
540
C
20-5/8
524
20-5/8
524
22-5/8
575
22-5/8
575
24-5/8
625
D
14-3/4
375
19-3/4
502
19-3/4
502
19-3/4
502
19-3/4
502
E
19
483
19
483
21
533
21
533
23
584
F
15
351
20
508
20
508
20
508
20
508
G
24-5/8
625
24-5/8
625
26-3/8
670
27-7/8
708
27-7/8
708
H
2O-5/8
524
24-5/8
625
24-5/8
625
24-5/8
625
30-5/8
778
3/4
C830M / Page 12 ► (19)
POSITION
DETAIL OF PIPING PLATE
ACCESS I-"— C�
1291
5/8
I SUCTION UNE
(16)
LIQUID.
(1118
CONDENSATE
H I I'
I
•
DRAINS 12)
SUCTION i COIL 11
LINE
(Horizontal)
5/8
16)
I
O
LIQUIDS — — — —
F
*-
I (5111
LINE
A OPTIONAL
ELECTRIC
i
:I
= I AIR FLOW I
HEA d / \
Installed) 1 I SLOWER)'.,I
RETURN
G
I.
I O
CONDENSATE
E AIR
LOW VOLTAGE _
DRAINS (21
OPENING.
(Right Side, --
LINE VOLTAGE
)Leh Side) nmm�nmm
I 5.3/8
IUp-Flow and
•� --
,
n oununuuw
5/8
11371 + +
Down -flow)
-
�3/4 Its!
SupplY Air
2.3/4
I
FRONT VIEW
119,1261, 11.811
SIDE VIEW
(70) 0
1251
I 1.31d •�(
I
TOP VIEW
L-- 144) 3-1/21891 —�
n
8
ACCESS I-"— C�
FILTER — — —
/,� \ II
H I I'
•
I I PIPINGPLATE \\ I I
SUCTION i COIL 11
LINE
LIQUIDS — — — —
_
I
LINE
A OPTIONAL
ELECTRIC
:I
= I AIR FLOW I
HEA d / \
Installed) 1 I SLOWER)'.,I
I I
G
I.
I_
LOW VOLTAGE _
—
('
�• I
(Right Side, --
LINE VOLTAGE
)Leh Side) nmm�nmm
•� --
,
n oununuuw
5/8
SuPPIY A(r
IIS
�3/4 Its!
SupplY Air
FRONT VIEW
119,1261, 11.811
SIDE VIEW
5/8
116)
r
CA'
C.
CERnRCATION APPUES ONLY
WHEN THE COMPLETE
SYSTEM IS usTEO
WITH ARI
ELITE 131M
HEAT PUMP OUTDOOR UNITS
Up To 14.70 SEER
HP26
Bulletin #210023
*18,600 to 59,400 Btuh (5.4 to 17.4 M) Cooling Capacity SuSeptebe
pe sedesApril 1996
*17,600 to 56,200 Btuh (5.2 to 16.5 M) Heating Capacity
*ARI Standard 210/240 and DOE Certified Ratings
Application — Energy efficient HP26 outdoor units are designed for ap-
plications with remotely located indoor blower -coil units or indoor add-
on coils in FM21 installations. Outdoor units are equally suited for instal-
1� lation on a slab at grade level or on a rooftop. A variety of matching
U
up -flow, down -flow and horizontal blower -powered indoor units, with
LISTED LISTED optional supplemental electric heat, provide selective sizing and instal-
lation versatility. For FM21 applications, see bulletin indexed in this
tab section. For indoor unit data, see section, Coils -Blower Coil Units.
Outdoor units are test operated at the factory to insure proper operation
and shipped ready for installation. Installer has only to locate unit and
make refrigerant line and electrical connections.
Typical Application
Approvals—Units have been tested with matching indoor units in the
Lennox Research Laboratory and rated according to U.S. Department
of Energy (DOE) test procedures and in accordance with ARI Standard
210/240-94. In addition, units have been sound rated in the Lennox re-
verberant sound test room in accordance with test conditions included
in ARI Standard 270-95. Units and components within are bonded for
grounding to meet safety standards for servicing required by U.L.,
N.E.C. and C.E.C. Units are U.L. and U.L.C. listed.
Equipment Warranty—The compressor has a limited warranty forten
years in residential installations and five years in non-residential
installations. All other covered components have a limited warranty
for five years. Refer to Lennox Equipment Limited Warranty included
with the unit for specific details.
Copeland® Compliant Scroll' Compressor — High efficiency com-
pressor features durability, steady uniform suction flow, constant d is -
charge flow, high volumetric efficiency, quiet operation and the abil-
ity to start under any system load. Use of the scroll compressor
eliminates the need for accumulator, crankcase heater, start capacitor
and start relay. The compliant scroll type compressor is a simple com-
pression concept design consisting of two involute spiral scrolls
matched together to generate a series of crescent-shaped gas pock-
ets between them. During compression, one scroll is stationarywhile
the other is allowed to orbit, not ro-
tate, around the fixed one. As this
motion occurs, gas is drawn into the
outer pocket sealing off the open pas-
sage. As the spiral movement contin-
ues, the pockets between the scrolls
are slowly pushed to the center of the
scrolls while simultaneously being re-
duced in volume. When the pocket
reaches the center, the gas is now at
high pressure and is forced out of a
port located in the center of the fixed
scroll. During compression, several
pockets are being compressed si-
multaneously resulting in a smooth,
nearly continuous compression
cycle. Continuous flank contact,
maintained by centrifugal force,
minimizes gas leakage and maxi-
mizes efficiency. The scroll compres-
sor is tolerant to the effects of liquid
slugging and contaminants. Should
this occur, the scrolls separate and
allow the liquid or contaminants to
be worked to the center and discharged. Low gas pulses during com-
pression minimize operational sound level. Factory installed muffler
in discharge line, external to the compressor, provides additional
sound reduction. Motor is internally protected from excessive cur-
rent and temperature. Compressor is installed in the unit on resilient
rubber mounts, assuring vibration free operation.
0 The maple leaf symbol in this bulletin denotes Canadian only usage where applicable
01996 Lennox Industries Inc.
NOTE — Due to Lennox' ongoing commirtment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. "
It
ARMATINGS
Unit Size
*ARI Standard 210/240 Ratings
&
*� Check
Model No.
Cool...
High
Htg.
low
Htg.
Total
Total
�HSPF
High
Total
Low
Indoor Units
and
Expansion
'Sound
Ratingy No.
Ca _
Btuh
Cap.
Cap.
Cool.
SEER
(EER)
Cool.
C.O.P.
High
Ht
Region IV
Htg.Ht
Low
Htg.
Valve Kit
In
(kW)
Stuh
Btuh
Watts
Watts
(Region V)
C.O.P.
Wag.
C.O.P.
Required
(kW)
(kW)
18,600
17,800
11,400
1805
12.00
3.02
1695
7.15
3.10
1555
2.17
e
B wer of nit
(5.4)
(5.2)
(3.3)
(10.30)
(6.35)
CB29M-=1/26 (Multi -Position)
18,800
17,800
11,400
1825
12.00
3.02
1705
7'10
3.08
1565
2.15
Bl�werCoil Unit
(5.5)
(5.2)
(3.3)
(10.30)
(6.30)
C629M-31(Multi-Position)
19 600
-(5:7)`
18,000
-(5:3)"(3:3)=`
11,400
`1820..(10.75),
12.50 ;
3.00'
1640
7.40
(6.50)
3.23
1525
2.22
BI ewer Coil Unit
830M-21/26 (Multi -Position)
*Factory
Installed
20,000
18,000
11,400
1795
13.00
3.26
1595
7'50
3.31
1485
2.26
Blower Coil Unit
(5.9)
(5.3)
(3.3)
(11.15)
(6.55)
CB30M-31 (Multi -Position)
18,800
18,000
11,800
1815
12.10
3
1690
7'40
332
1505
2.
0 Blower Coil Unit
(5.5)
(5.3)
(3.5)
(10.35)
.03
(6.70)
.12
CVP10-26/EC10Q3 (UpLFlow)
18,800
17,800
11,400
1815
12.00
3.03
1710
7'10
3.07
1570
2.15
IndaorCoil (AFM21)
(5.5)
(5.2)
(3.3)
(10.351
(6.30)
C26-21(FC►;(Up-Flow)
1.5 Ton.
8
19,200
18,000
11,400
1820
12.10
3.09
1685
7.20
3.14
1560
2.17
Indoor Coil (AFM21)
(72)
(5.6)
(5.3)
(3.3)
(10.55)
(6.35)
C26-26(W)(FC) (Up -Flow)
20,000
18,000
11,400
1830
12.60
3. 21
1650
7'30
3.20
1540
2.19
Indoor Coil (AFM21)
(5.9)
(5.3)
(3.3)
(10.95)
(6.40)
C26-311W1(FC) (Up -Flow)
18,600
17,800
11,400
1815
11.70
3.00
1750
7'00
2.99
1595
2.11
Indoor Coil (AFM21)
(5.4)
(5.2)
(3.3)
(10.25)
(6.20)
CR26-21 (Down -Flow)
LB -85759F
19,800
17,800
11,400
1825
12.50
3.18
1670
7.25
3.15
1545
2.18
Indoor Coil (AFM21)
(56J19)
(5.8)
(5.2)
(3.3)
(1085)
(6.35)
CR26•-31 (Down -Flow)
18,800
17,600
11,200
1815
11.80
3.03
1740
7'00
2.98
1590
2.09
Indoor Coil (AFM21)
(5.5)
(5.2)
(3.3)
(10.35)
(6.15)
CH2'1-21 (Horizontal)
18,600
17,800
11,200
1815
12. 00
3
1710
7'05
312
1575
2.
Indoor Coil (AFM21)
(5.4)
(6.2)
(3.3)
(10.25)
.00
(6.20)
.05
CH23-31 (Horizontal)
19,400
17,800
11,400
1825
12.20
3.12
1665
7.20
3.16
1560
2.14
Indoor Coil (AFM21)
(5.7)
(5.2)
(3.3)
(10.65)
(6.30)
CH2�-41 (Horizontal)
22,200
22,000
14,400
2170
11.85
2 99
2000
7'85
332
1825
2
Blower Coil Unit
(6.5)
(6.4)
(4.2)
(10.20)
(6.85)
.
.33
CB29M-21/26 (Multi -Position)
23,000
22,600
14,400
2190
12' 10
3
2000
7'80
3
1830
2 32
Blower Coil Unit
(6.7)
(6.6)
(4.2)
(10.50)
.08
(6.80)
.31
.
CB29M-31 (Multi -Position)
23,200
22,800
14,600
2210
12'10
3.08
1975
8'00
3.38
1825
2.34
Blower Coil Unit
(6.8)
(6.7)
(4.3)
(10.50)
(6.90)
CB29M-41 (Multi -Position)
•Factory
24,000
22,800
14,400
2190
12.70
3.21
1940
8.05
3.45
1795
2.37
Blower Coil Unit
Installed
(7.0)
(6.7)
(4.2)
(10.95)
(7.00)
CB30M-21/26 (Multi -Position)
24,400
22,400
14,200
2125
13. 40
3
1840
8'25
3
1710
2.44
Blower Coil Unit
(7.1)
(6.6)
(4.2)
(11.45)
.36
(7.10)
.60
CB30M-31 (Multi -Position)
22,800
22,600
14,200
2195
12. 05
3
1980
7'80
335
1825
231
0 Blower Coil Unit
(6.7)
(6.6)
(4.2)
(10.40)
.04
(6.80)
.
.
CVP10-213/EC10Q3 (Up -Flow)
2Ton
22,400
22,600
14,600
2195
11'80
2.99
2005
7'80
3.32
1835
233
.
Indo=irCoil (AFM21)
(6.6)
(6.6)
(4.3)
(10.20)
(6.85)
C26-21(FC) (Up -Flow)
HP26-024
(72)
23,000
22,800
14,600
2195
12'10
3.06
1970
8'00
3.41
1815
2.36
Indoor Coil (AFM21)
(6.7)
(6.7)
(4.3)
(10.45)
(6.95)
C26-25.W)(FC) (Up -Flow)
24,000
22,800
14,400
2200
12' 70
3
1925
8'10
338
1795
2.
Indoor Coil (AFM21)
(7.0)
(6.7)
(4.2)
(10.90)
.19
(7.00)
.48
C26-31;W)(FC),(Up-Flow)
22,000
22,600
14,400
2185
11.50
2,95
2050
7'70
3.23
1860
2.29
Indoor Coil (AFM21)
(6.4)
(6.6)
(4.2)
(10.05)
(6.75)
CR26-21 (Down -Flow)
LB -85759F
23,800
22,800
14,400
2200
12.50
3.17
1960
8.00
3.42
1805
2.36
Indoor Coil (�FM21)
(56J19)
(7.0)
(6.7)
(4.2)
(10.80)
(6 95)
CR26-31 (Down -Flow)
22,600
22,200
14,200
2190
11.80
3.02
2035
7'60
3.22
1860
2.26
Indoor Coil (AFM21)
(6.6)
46.5)
(4.2)
(10.30)
(6.75)
CH22 21 (Horizontal)
22,800
22,400
14,400
2190
12.00
3.05
2000
7'75
3.30
1835
2.30
Indoor Coil (AFM21)
16.7)
(6.6)
(4.2)
(10.40)
(6.80)
CH2� 31 (Horizontal)
23,600
22,600
14,400
2195
12.35
3.15
1935
8:00
3.44
1805
2.35
Indoor Coil (AFM21)
(6.9)
(6.6)
(4.2)
(10.75)
(6 95)
CH2°-41 (Horizontal)
'Sound Hating Number in accordance with test conditions included in ARI Standard 270.
*Heating Seasonal Performance Factor.
;;` *Rated in accordance with ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines;
Cooling Ratings - 95'F (35'C) outdoor air temperature and 80°F (27'C) db/67'F (19°C) wb entering indoor coil air.
High Temperature Heating Ratings - 47'F (8°C) db/43°F (6°C) wb outdoor air temperature and 709F (21°C) db entering inaoor coil air.
Low Temperature Heating Ratings - 17'F db/15'F wb outdoor air temperature and 70'F (21'C) db entering indoor coil air.
*Furnished as standard with coil unit.
**Kit is required and must be ordered extra, unless shown as factory installed.
AFM21 Heat Pump Control - Use coil listed with any Lennox furnace that meets system design requirements. See FM21 page in this section for additional data. i
NOTE - Shaded area denotes most popular blower coil combination.
HP26 / Page 3 ►
•
0
AR/RATINGS.'
Unit Size
*ARI Standard 210/240 Ratings
rHP26-024
--Check
Cool.
High
Ht
Low
Ht
Total
Outdoor
Coil
Net face area
sq. ft. (m2)
Total
♦HSPF
High
Total
Low
Low
&
Model No.
trtdoor Units
and
and
Rating *Sound
Btu
:Cap.
Cap.
Cool.
SEE(EER)
Cool.gh
C.O.P.
Hi
Region IV
Htg.
w
Htg.
15.56(l.45)
Valve Kit
Required
Idbl
(kW)
Btuh
Btuh
Watts
5/16(8)
5/16(8)
Watts
(Region V)
C.O.P.
Watts
C'O'P
2
2
2
2
(kW)
(kW)
Fins per inch (m)
22 (866)
22 (866)
22 (866)
22 (866)
22(856).
22(866)
22 (866)
Outdoor Coil
Fan
Diameter in. (mm) - No. of blades
20 (508) - 4
55,400
54,800
34,600
5335
12.30
3.05
5190
7.50
3.09
4450
2.28
Blower Coil Unit
1/4(187)
1/3(249)
(16.2)
(16.1)
(10.1))
3000 (1415)
(10.40)
3100 (:465)
4200 (1980) •
(6.70)
Rpm
825
825
CB31MV-51 (Multi -Position)
825
825
56,100
54,400
35,000
5405
12.00
3
5260
7.50
304
4535
2
Blcwer Coil Unit
6 lbs. 8'oz.
(2.95 kg)
8 lbs. 12 oz.
(3.97 kg)
(16.4)
(15.9)
(10.3)
15 lbs. 8 oz.
(7.03 kg)
(10.40)
.05
3/8(9.5)
(6.70)
.
3/8 (9.5)
.27
CB30M-51 (Multi -Position)
Vapor line conn. o.d. - in. (mm) sweat
5/8(15.9)
56,600
54,600
34,400
5350
12.50
3.11
5210
7.45
3.07
4485
2.25
Blcwer Coil Unit
352 (160)
372 (169)
(16.6)
(16.0)
(10.1)
(10.60)
(6.65)
C831 MV -65 (Multi -Position)
•Factory
Installed
57,500
155,200
35,000
5535
12'00
3.05
5390
7.35
3.01
4670
2.20
Blower Coil Unit'
C830M-35 (Multi -Position)
H P26-060
(80)
55,000
(16.1)
55,000
(16.1)
35,600
(10.4)
5585
11 30
(985)
2.89
5415
7.35
(6.50)
3.02
4715
2.22
0 Blower Coil Unit
ICVP10-5VEC1004 (Up -Flow)
57,200
(16.8)
55,600
(16.3)
35,200
(10.3)
5605
11.75
(10.20)
2.99
5340
7'35
(6.50)
3.05
4690
2.21
0 Blower Coil Unit
CVP10-6E1EC10Q5(Up-Flow)
59,400
55,600
35,200
5630
12.10
3.09
5310
7.45
3.08
4650
2.23
Indoor Coil (AFM21)
(17.4)
(16.3)
(10.3)
(10.55)
(6.60)
C26-65(FC)EAP (Up -Flow)
LB -85759G
(56J20)
59,300
56,200
35,600
15630
12.10
3.09
5150
7.65
3.20
4580
2.29
Indoor Coil (AFM21)
(17.4)
(16.5)
(10.4)
(10.55)
(675)
CH23-68(Horizontal)
'Sound Rating Number in accordance with test conditions included in ARI Standard 270.
*Heating Seasonal Performance Factor.
*Rated in accordance with ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines;
Cooling Ratings - 95'F (35'C) outdoor air temperature and 80'F (27'C). db/67'F (19'C) wb entering indoor coil air.
High Temperature Heating Ratings- 471F (8'C) db/43'F (6'C) wb outdoor air temperature and 70'F (211C) db entering indoor coil air.
Low Temperature Heating Ratings - 17'F db/15'F wb outdoor air temperature and 70°F (21'C) db entering indoor coil air.
*Furnished as standard with coil unit.
*NOTE
is required and must be ordered extra, unless shown as factory installed.
AFM21 Heat Pump Control - Use coil listed with any Lennox -furnace that meets system design requirements. See FM21 page in ,his section for additional data.
NOTE - Shaded area denotes most popular blower coil combination.
SPECIFICATIONS
Model No.
H1126-018:<
rHP26-024
HP26-030
HP26-036
HP2G042
HP26-048
HP26-060
Outdoor
Coil
Net face area
sq. ft. (m2)
Outer Coil
11.91 (1.11)
11.91 (1.11)
16.04 (1.49)
16.04 (1.49)
18.33 ;1.70)
24.06 (2.24)
24.06 (2.24)
Middle Coil
----
----
----
----
----
----
23.33 (2.17)
Inner Coil
8.27 (0.77)
8.27 (0.77)
15.56(l.45)
15.56(l.45)
17.78 0.65)
23.33 (2.17)
17.28 (1.61)
Tube diameter - in. (mm)
5/16 (8)
5/16(8)
5/16(8)
5/16(8)
5/16(8)
5/16(8)
5/16(8)
No. of rows
2
2
2
2
2
2
3
Fins per inch (m)
22 (866)
22 (866)
22 (866)
22 (866)
22(856).
22(866)
22 (866)
Outdoor Coil
Fan
Diameter in. (mm) - No. of blades
20 (508) - 4
20 (508) - 4
24 (610) - 3
24 (610) - 3
24 (610) - 3
24 (610) - 4
24 (610) - 3
Motor hp (W)
1/10 (75)
1/10(75)
1/6024)
1/6(124)
1/6(124)
1/4(187)
1/3(249)
Cfm (L/s)
1860 (880)
1860 (880)
3000 (1415)
3000 (1415)
3100 (:465)
4200 (1980) •
4600 (1350)
Rpm
825
825
825
825
825
825
1075
Watts
165
; 165
230
230
230
345
420
"Refrigerant furnished (HCFC -22)
7 lbs. 1 oz.
(3.20 kg)
6 lbs. 8'oz.
(2.95 kg)
8 lbs. 12 oz.
(3.97 kg)
9 lbs. 8 oz.
(4.31 kg)
11 lbs. 0 oz.
(4.99 Lg)
12 lbs. 8 oz.
(5.67 kg)
15 lbs. 8 oz.
(7.03 kg)
Liquid line conn. o.d. - in. (mm) sweat
3/8(9.5)
3/8(9.5)
3/8(9.5)
3/8(9.5)
3/8 (9.5)
3/8(9.5) '
3/8(9.5)
Vapor line conn. o.d. - in. (mm) sweat
5/8(15.9)
3/4(19)
3/4(19)
3/4(19)
7/8(2--.2)
7/8(22.2)
1-1/8 (28.6)
Shipping wt. - lbs. (kg) 1 package
190 (86)
191 (87)
1 236 (107)
1 244 (111)
262 (119)
352 (160)
372 (169)
'Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
HP26 / Page 6 ►
N
ELECTRICAL DATA
0)
Model No.
HP26-018 1
HP26-024
HP26-030
HP26-036
HP26-042
Line voltage data.._
208 230v
60hz-lph
208/230v
60hz-lph
208/230v
60hz-lph
208/230Y
60hz-lph
208/230v
60hz-3ph
208/230v
60hz-lph
208/230v
60hz-3ph
Compressor
Rated load amps
8.4
10.3
13.5
16.1
10.3
18
12.5
Power factor .96 .96 .96 .96 .82 .97
.82
Locked rotor amps 47 56 72.5 88 77 104
88
Outdoor Coil
Fan Motor
Full load amps
0.8
0.8
1.1
1.1
-.1
1.1
1.1
Locked rotor amps 1.6 1.6 2.0 2.0 2.0 2.0
2.0
Rec. max. fuse or circuit breaker size (amps)
15
20
30
35
20
40
25
"Minimum circuit-ampacity
11.3
13.7
1 18
1 21.2
14
23.6
16.8
'Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
ELECTRICAL DATA
Model No.
ELECTRIC
HP26-048
Vapor
Line (o.d.)
in.
HP26-060
C -
Line voltage data
2087230v
60hz-lph
208/230v
60hz-3ph
460v
60hz-3ph
208/230v
60hz-lpht
208/230v
60hz-3ph
460v
60hz-3ph
Compressor
Rated load amps
23.8
13.5
7.4
28.9
17.4
9.0
Power factor .94 .87 .87 .94 .85
.85
Locked rotor amps 129 99 49.5 169 123
62
Outdoor Coil
Fan Motor
Full load amps
1.7
1.7
1.1
2.3
2.3
1.1
Locked rotor amps 3.8 3.8 2.2 4.8 4.8
2.2
Rec. max. fuse or circuit breaker size (amps)
50
30
15
60
40
20
*Minimum circuit ampacity
31.5
18.6
10.4
38.5
24.1
12.4
"Neter to National or Canadian tlectrlcal Code manual to determine Wife, Luse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
FRELD WIRING
r ------ rDISCONNECT-1 rDISCONNECT-1
THERMOSTAT SWITCH SWITCH LENNOX A - Two Wire Power (see Electrical Data)
(Optional)
L-- J L' IBy Others) J L(By Others) J OPTIONAL
Tf -- - SUPPLEMENTAL B - Two or Three Wire Power (size b heater capacity)
REFRIGERANT LINE KITS
OutdoorLine
Unit
Model No.
ELECTRIC
Liquid
Line (o.d.)
Vapor
Line (o.d.)
in.
B HEAT
C -
Two Wire Power (size to indoor coil blower motor)
HP26 018
OPTIONAL -iD
rLL
-
Two Wire Low Voltage - 18 ga- minimum
5/8
OUTDOOR
L15-26-25 25 8
L15-26-35 35 11
L15-26-50 50 15
THERMOSTATT J D F
E -
Eight Wire Low Voltage - 18
g g gz. minimum - with Electric Heat
9.5
_
-
Ten Wire Low Voltage with Optional Outdoor Thermostat
L15-41-40 40 12
r DIS_CON_NEC_T,
HP26-042
HP26-048
L15-65-30 30 9
LENNOX
I SWITCH
F -
Four Wire Low Voltage - 18 ga minimum
OUTDOOR
L (By Others)
HP26-060
*Not available
UNIT
CLENN
INDOOROX UNIT
G -
Three Wire Low Voltage - 18 g 3. minimum
- Field Wiring Not : urnished -
G
All wiring must conform to NEC or CEC and local electrical codes.
REFRIGERANT LINE KITS
OutdoorLine
Unit
Model No.
Line
Set Length
Model No.
ft. m
Liquid
Line (o.d.)
Vapor
Line (o.d.)
in.
mm
in.
mm
HP26 018
L15-26-20 20 6
3/8
9.5
5/8
15.9
L15-26-25 25 8
L15-26-35 35 11
L15-26-50 50 15
HP26-024
HP26-030
HP26-036
L15-41-20 20 6
3/8
9.5
3/4
19
L15-41-30 30 9
L15-41-40 40 12
L15-41-50 50 15
HP26-042
HP26-048
L15-65-30 30 9
3/8
9.5
7/8
22.2
L15-65-40 40 12
L15-65-50' 50 15
I
HP26-060
*Not available
3/8
1 9.5
1 1-1/8
22.2
rvv i C - nerriyuranc nne sec snows not exceea 5u n. l i5ml in any mstaiiauon
*Field fabricate.
NOTE -48" 11219 mm) clearance required on top of unit.
*NOTE -One side of coil may be 12 (305) inches.
HP26 / Page 7 jo.
DIMENSIONS;-
- INLET AIR
l
/ INLET
AIR
COMPRESSOR
y,
INLET Q AIR COIL DRAIN
OUTLETS;
TOP VIEW (Around perimeter
of base)
ELECTRICAL
13 1 INLETS C
— I
VAPOR DISCHARGE AIR
- LINE INLET
O-
41/2 (114)
A 9-
H
` D 2-9/16:
LIQUID (65)
LINE INLET
Li
(�K�j �K�J 2-3/4 F 4
2 4-7/8 (22) (70) (102) (102)
14
(51) E 1W 6-1/16--4-
G 2 1-3/8 (154)
(51) (35) SIDE VIEW
SERVICE ACCESS
Model No.
A
8
C
I D
E
F
G
H
J
K
in.
27-7/8
25-7/8
29-7/8
12-1/4
22-7/16
14-7/16
22-1/8
16-3/4
2-7/8
5-1/2
HP26�018-02
mm
708
657
759
311
570
367
562
425
730
140
HP264
in.
30-7/8
32-1/8
34-1/16.
12-3/4
26-5/8
18-5/8
28-1/8
17-1/4
3-7/8
7-1/2
HP26-030
mm
784
816
865
324
676
473
718
438
98
191
HP26-036
in.
34-7/8
32-1/8
34-1/16
13-3/4
26-5/8
18-5/8
28-1/8
18-1/4
3-7/8
7-1/2
HP26-042
mm
886
816
865
349
676
473
718
464
-
98
191
in.
44-7/8
32-1/8
34-1/16
14-1/4
26-5/8
18-5/8
28-1/8
18-3/4
3-7/8
i
r7-1/2
HP26-048
mm
1140
816
1 865
362
676
473
718
7476
98
191
HP26-060
.�
IERMOSTATS (Continued)
i
L22 & L23 SERIES THERMOSTATS
(For Heat Pump Systems Only)
i
Model No. Description Catalog No.
L221407HP .......... 2 Heat/1Cool 7 -Day ........... 91H72
L232407HP ......... 3 Heat/2 Cool 7 -Day ......... 91H73
A2000 -ROS ..... Outdoor Temperature Sensor ..... 691-1127
L22 & L23 Series 7 -Day Thermostats feature full independent
seven-day programming, automatic or manual changeover, built-
in time delays, large easy -to -read LCD readout with actual time
and temperature in °F or °C for alternating inside and outside
temperature readout (with optional outdoor temperature sensor).
Two stage.cooling model features low or high speed cooling op-
eration indicators. "Check System" indicator shows a need for
service. Also features "Aux" and "Enver indicators for supple-
mental or emergency heat operation. Check filter indicator
flashes at preset interval. Thermostat features system selector
switch (Off -Heat -Cool -Auto) and fan switch (On -Auto) forcontinu-
ous or intermittent blower operation. Indicator lights show "Am-
ber" indicating system is operating in manual mode or (flashing)
3 hour override. "Green" light indicates system demand (turns
red during emergency heat operation or flashes red indicating
check system). Solid-state electronic technology eliminates bat-
tery back-up and maintains thermostat settings during power fail-
ure indefinitely. Thermostat has four separate time and tempera-
ture settings per day. Individual slide switches are used to settime
begin and heat and cool temperatures: "+" and "-" buttons set
time of day. "Day" button sets day of week. "Prog/Review" button
reviews daily programs and displays programmed time period
setpoints. "Manual" button allows manual .control of tempera-
ture. "Clear" button erases programmed.setpoints when repro-
gramming. "Enter" button enters time of day and temperature
setpoints into memory. "Enver Ht" button allows emergency heat
operation. Thermostat also features adjustable lockout of supple-
mental electric heat. Monitoring of compressor run times and
heating times in hours and cycles is also available. Pressing front
cover reviews thermostat settings. Intelligent temperature recov-
ery automatically computes time to operate system to meet ther-
mostat day/night settings.
i
Optional Outdoor Temperature Sensor is also available and must be
ordered extra. With optional sensor, thermostat will give a readout
of present outdoor temperature and the lowest and highest outdoor
temperatures of the day and times at which they occurred.
—2—