10-0377 (MECH)
Applicant: Architect or Engineer: ------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. cens Cla s: B cense No.: 447802 �% ontractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects theapplicantto acivil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec: , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERD4IT Owner: PATTEN INDUSTRIES, INC. 635 W. LAKE STREET ELMHURST, IL 60126 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Contractor: DESIGN BUILD STRUCTURES, INC.. 779.80 WILDCAT -DRIVE, SUITE PALM DESERT, CA 92211 (760)772-0800 Lic. No.: 447802 Date: ' 5/03/10 #D Q I i *tA 04 2010 UI EFF OF s a Q;a NTA - - - - pre t._tcr— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0000821-2009 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become sub] ec o the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwit- mply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($ 100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made•to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereljy authorize representatives of this ` un to enter u on the above-mentioned pr ert for inspection purposes. \\\ 01 �. Date: � on (Applicant or Agent): P.O. BOX 1504 78-495 CALLE TAMPICO ; LA QUINTA, CALIFORNIA 92253 _ Application Number: 10-00000377_7 , Property Address: 80512 RIVIERA APN: 762-200-035- - Application description: MECHANICAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 10000 Applicant: Architect or Engineer: ------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. cens Cla s: B cense No.: 447802 �% ontractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects theapplicantto acivil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec: , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERD4IT Owner: PATTEN INDUSTRIES, INC. 635 W. LAKE STREET ELMHURST, IL 60126 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Contractor: DESIGN BUILD STRUCTURES, INC.. 779.80 WILDCAT -DRIVE, SUITE PALM DESERT, CA 92211 (760)772-0800 Lic. No.: 447802 Date: ' 5/03/10 #D Q I i *tA 04 2010 UI EFF OF s a Q;a NTA - - - - pre t._tcr— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0000821-2009 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become sub] ec o the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwit- mply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($ 100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made•to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereljy authorize representatives of this ` un to enter u on the above-mentioned pr ert for inspection purposes. \\\ 01 �. Date: � on (Applicant or Agent): Application Number .. 10-00000377 Permit . . . MECHANICAL Additional desc.. Permit Fee . . . . 46.00 Plan Check Fee 11.50 Issue Date Valuation . . . . 0 Expiration Date 10/30/10 Qty Unit Charge Per Extension BASE FEE 15.00 2 .00 9. oono, ' RA MRCH R/r =-AT4P/i nnTl RTTT 19 .00 2..00 6.5000 EA MECH AH <=10K CFM. 13.00 ---------------------------------------------------------------------------- Special Notes and Comments ADD DUCTLESS AC UNIT TO 425 SF GARAGE AND 210 SF CART GARAGE. CONTR. TO VERIFY ADEQUATE COMBUSTION AIR FOR MECH EQUIPT'. 2007 CMC 2008 ENERGY. Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) .1.00 ENERGY REVIEW FEE 1.15 Fee summary Charged Paid Credited. Due ----------------- ---------- ---------- ---------- Permit Fee Total 46.00 .:00 .00 46.00 Plan Check Total 11.50 .00 .00 11.50 Other Fee Total 2.15 .00 .00 2.15 Grand Total 59.65 .00 .00 59.65 LQPERAIIT 5 Bin # City of La Quinta Building & Safety Division Permit # P.O. Box 1504,78-495 Calle Tampico O 3 1 La Qulnta, CA 92253 - (7.60) 777-7012 Building Permit Application and Tracking_Sheet Project Address: 8 0 Sr Owner's Name: ll A. P. Number: Address: (� 3 5 'Vi Legal Description: City, ST, Zip: t! u'1 ?41) 2S 1 f -L_ 2 Contractor. 'J251..:.::.;;..;,;xa;::«:: �; Telephoner �.nY� � s�>::<� �y Zvi>��r�`':: Address: _1C �� —� $O 2 J p Protion: .` f `--f�T City, ST, Zip:el P!'w�f✓L ` `[� ����� { �Yvv'`L/ }'f3 �3Y..n. ��V�'PCj �{+tr1'v. State Lia # 4 7 86 -I-- City Lie. M. Arch., Engr., Designer: Address: City., ST, Zip: n .Y`r:..Jh:•j:. Telephone: %.`:?Y" `�;�'•:;'s�.a y:>{:,,,•. State Lie. #: ���•>�����%w� �.rg;; •sN„_`:: Name of Contact Person: Construction Type: YP Olccupancy: Project j type (circle one): New Add' -s Alter •Repair Demo Sq. Pt.; #Stories: #Units: Estimated Value of Project: , ©� Telephone # of Contact Person: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Retial TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Plan Check -Balance Truss Calcs. Called Contact Person Tide 24 Cates. Plans picked up Constracticn Flood plain pian Plans resubmitted Mechanlca° Grading plan 2°' Review, ready for correctio tssu Electrical Subcontactor List Called Contact Person Plumbing S.M.I. Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading Developer Impact Fee A.I.P.P. IN HOUSE:- Review, ready for corrections/issue Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 3) The undersigned certifies that, Knaulf Fiber Glass Premitan EWilding Insulation has been installed in accordance with the manufacturers ��� "llhis Is my Insulation." re-Dornmert.ded applications for these products. Insulation Type (check applicable. items) M 0' Kraft Foil FSK Blowing Nurnber.ot Coverage Z Unfaced Faced Faced Foil- Insulation R -Value Th-.ckness 'Packages Area(SF) __4 F33 Sloped Ceilings. O O O C O in. sq. ft. Attic Areas in. U, 01 M, Floors in. sq. ft. Above 913 7k: CD GradeVails 0 0 0 0 in. sq. ft. Basement/ in. sq. ft. Crawls paces Street Address Lot No. Subdivision _j pitV state, 7ip L.J. Installing Corr:;;, State Liomse itW /7, ned Date. ;u (.n other valuable homeowner papers. Men this is o,% to the puta"et of Me property. property sold. this oerfficate should be passed .... .. . ...... .... a 1401,F couQsE Aejncemr QArio 7 `- war -To 5rALE . . Cl -FY OF LA QUINTA 3UILDING & SAFETY DEPT APPROVED' FOR CONSTRUCTf N ` DA rE Zoll By i lbpl �t 9:,L i I�r0 .4t f2 Fop fit+. �Qur A/c Vim.• bi x I 1 • �3�EXisrintCT . A/C S ysf�MS StrtEET " Y. Construction is NOTPF""!"— CONSTRUCTION HOUIkS on the following Coda ( October 1st - April ,Monday :! NewYear sSaturday.. Dr. M►I� - Friday: 7:00. a.m. to 5:30 p.m- 8:00 a.m. to 5:00 p .m, SiandaY: I �.�i .: ;,'r. C, P= - ' .. ' ; 4.: y . None Government Code H611ays• � None May 1st - Septembe30th r Day Monday - Friday':. 6:00 aan. to 7:00 p.nL Saturday: . 3 8:00 a.m. to 5:00 p.m. Sunday: None Dai Government Code Holidays: None 10 �,Sgiving Day uhrishas Day "AN ADEQUATELY SIZED DEBRIS CONTAINER A REINSPECTION FEE OF $30 IS REQUIRED ON THE JOB SITE DURING ALL WILL BE CHARGED IF THE APPROVED PHASES OF CONSTRUCTION AND MUST BE PLANS AND 108 CARD ARE NOT ON EMPTIED AS NECESSARY. FAILURE TO DO SO A SCHEDULED MAY CAUSE THE CITY TO HAVE THE CONTAINER IINSPECTION,FOR DUMPED AT THE EXPENSE OF THE OWNER/ NO EXCEPTIOiNSI CONTRACTOR." BUILDING ENERGY ANALYSIS REPORT PROJECT: Patten Res. Golf Cart Garage 80512 Riveriera La Quinta, CA 92253 Project Designer: Design Build Structures, Inc 77980 Wildcate Dr. Suite #2 Palm Desert, CA 92211 760-772-0800 Report Prepared by: Gina Rose -Starkey EQS, INC 42335 Washington St. #F330 _.._..._.._ ._..�_..._ Palm Desert, CA 922 760-674-2345 t, ,l Job Number: Date: 4 :. 4/8/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5,O by.EnergySoft.. _ .User Number 5862_ - Run Code:_ 2010-04-08T11:28:3 /D: . TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro_5.0 by EnergySoft Job Number: ID: User Number. 5862 1 2 3 8 11 12 13 14 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Patten Res. Golf Cart Garage Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ AdditionlAlteration Date 4/8/2010 Project Address 80512 Riveriera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 210 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features— If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part . , of 5 Status Roof Wood Framed Attic R-22 210 Existing Wall Wood Framed R-13 355 Existing Door Opaque Door Insu/ 88 Existing Slab Unheated Slab -on -Grade None 210 Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (lAq 28.7 0.870 0.59 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 None n/a Room PTAC without Sic 10.4 EER Setback New HVAC DISTRIBUTION Cuct Location Heating Cooling Duct Location R -Value Status Existing Golf Cart Garage Ductless/ with Fan Ductless n/a rYa New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010-0408711:28:3 ID: Page 3 of 14 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF-1 R Project Name Patten Res.._Go1f Cart Garage Building Type m Single Family ❑ Addition Alone ❑Muni Family ❑Existing+ Addition/Alteration Date 4/8/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The erforcement agency determines the adequacy of the justification, and may.•reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 210.0 ft' Exposed Slab Floor, 4.000" thick at Existing Golf Cart Garage HERS REQUIRED. VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnergyPro 5.0 by EneMySoft.. User Number: 5862 Run Code: 2010-0408711:28:3 ID: _ Pa e 4 of 14 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Patten Res. Golf Cart Garage ❑ Multi Family ❑ Existing+ Addition/Alteration 4/8/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 15.66 13.43 2.23 Space Cooling 253.65 194.55 59.11 Fans 46.37 45.79 0.58 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 315.69 253.77 61.91 Percent Better Than Standard:. 19.6 % BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof . Wall Area Area Number of Dwelling Units: 1.00 (N) 152 0 Fuel Available at Site: F Natural Gas (E) 0 0 Raised Floor Area: 0 (S) 120 0 Slab on Grade Area: 210 (tM 200 29 Average Ceiling Height: 10.0 Roof 210 0 Fenestration Average U -Factor: 0.87 TOTAL: 29 Average SHGC: 0.59 Fenestration/CFA Ratio: .1.3.7% - 13.7%.REMARKS REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Do'cumentatio'n Author Company EQS, INC 4Bl1010 Address 42335 Washington St. #F330 Name Gina Rose -Starkey City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone 760-674-2345 Signed Date , The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing; verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business,& Professions Code) , Company Design Build Structures, Inc 77980 Wildcate Dc Suite #2 Address Name City/StatefZip Palm Desert, CA 92211 Phone 760-772-0800 Signed License # Date EnemvPro 5.0 by Ede Soft . User Number: 5862. RunCode: 2010-0408711:28:3 /D. Page 5 of 14 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name Patten Res. Golf Cart Garage Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/8/2010 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 210 0.043 R-22 0 0 Existing 4.2.1-A6 Existing Golf Cart Garage Wall 88 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Golf Cart Garage Door 64 0.500 /nsu/ 0 90 Existing 4.5.1-A3 Existing Golf Cart Garage Wall 96 0.102 R-13 180 90 Existing 4.3.1-A3 Existing Golf Cart Garage Door 24 0.500 /nsu/ 180 90 Existing 4.5.1-A3 Existing Golf Cart Garage Wall 171 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Golf Cart Garage Slab 210 0.730 None 0 180 Existing 4.4.7-A 1 Existing Golf Cart Garage FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 3.7 0.870 NFRC 0.59 NFRC 270 Existing Double Mt/ Tinted Default Existing Golf Cart Garage 2 Window 4.0 0.870 NFRC 0.59 NFRC 270 Existing Double Mt/ Tinted Default Existing Golf Cart Garage 3 Window 21.0 0.870 NFRC 0.59 NFRC 270 Existing Double Mt/ Tinted Default Existing Golf Cart Garage N (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 EnergyPro 5.0 by EnergySoft User Number: 5862 Run Code: 2010-04-08T11:28:3 /D: Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Patten Res. Golf Cart Garage Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/8/2010 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existing Altered Removed Volume Year Built Existing Golf Cart Garage Existing Golf Cart Garage 210 2,100 1988 Totals 01 210 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing Golf Cart Garage 1 None n/a Room PTAC without Sidi 10.4 EER Setbac New HVAC DISTRIBUTION System Name Heating Cooling Duct Duct Location R -Value Ducts Tested? Status Existing Golf Cart Garage Ductless/ with F Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Lcss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 0 Small Gas Kitchen Pipe Ins 40,000 50 0.53 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E w o_ Hot Water Piping Length ff o 16 c Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnergyPro 5.0 by EnerqySoft User Number: 5862 Run Code: 2010-04-08T11:28:3 ID: Pa e 7 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Patten Res. Golf Cart Garage Date 1 4/8/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112 . §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, ane entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating :source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Registration Number: Registration Date/Time: HERS Frovider: EnergyPro5.0 by EnergySoft User Number: 5862 Run Code: 2010-04-08T11:28:35 /D: Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Patten Res. Golf Cart Garage 4/8/2010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a lite -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units ':arger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficac_/ and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. Registration Number: Registration Date/Time: HERS Provider: EnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010.0408711:28:35 /D: Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Patten Res. Golf Cart Garage 4/8/2010 §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of. power as determined according to §130(d). §150(k)l5:. Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. Registration Number: Registration Date/Time: HERS Provider: EnergyPro6obyEnergySoft User Number.' 5862 RunCode: 2010-04-08T11:28:35 /D: Pae 10,of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Patten Res. Golf Cart Garage Date 4/8/2010 System Name Existing Golf,Cart Garage Floor Area 210._ ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 564 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 115 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent. CFM Sensible Output per System 0 10,195 998 186 6,935 Total Output Btuh 0 0 Output Btuh/s ft 0.0 0 0 Cooling System 0 0 Output per System 18,000 4,895 2,158 115 5,385 Total Output Btuh 18,000 0 3,156 0 Total Output Tons 1.5 0 Total Output Btuh/s ft 85.7 —01 Total Output s ft/Ton 140.0 1 15,091 12,320 Air System CFM per System 400 HVAC EQUIPMENT SELECTION Airflow cfm 400 Fujitsu-18CL 14,993 1,385 0 Airflow cfm/s ft 1.90 Airflow cfm/Ton 266.7 0 Jan 1 AM Outside Air % 28.8% Total Adjusted System Output 14,993 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 1,385 Au3 3P m Outside Air cfm/s ft 0.55 Note: -Values above.given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 57 OF O' Outside Air 115 cfm Supply Fan 400 cfm 70 OF 57 OF 105 OF -- Heating Coil 105 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of.Coolin Peak _ 112/78°F 84/66°F Outside Air Arc 115 cfm 72/61 OF 84/66°F 55/54°F c Supply Fan Cooling Coil 55 / 54 OF 400 cfm 53.5% I ROOM I� - 72/61 OF EnergyPro5.0 by EnergySoff User Number: 5862 Run Code: 2010-04-08T11:28:35 /D: Page 1.1 of 14 ROOM LOAD SUMMARY Project Name Date Patten Res. Golf Cart Garage 4/8/2010 System Name Floor Area Existing Golf Cart Garage 210 ROOM LOAD SUMMARY Zone Name I Room Name I Mult. I CFM I Sensible 1 Latent I CFM I Sensible I Latent I CFM I Sensible Existing Golf Cart Garage I Existing Golf Cart Garage 1 1 1 5641 10,1951 9981 5641 10,1951 9981 186 6,935 PAGE TOTAL TOTAL* 564 10,19 998 186 6,935 564 10,195 998 186 6,935 L' Total includes ventilation load for zonal systems. I EnemyPro 5.0 b Y EnerqySoft User Number: 5862 RunCode: 2010-04-08T11:28:3 /D: Pae 12 of 14 ROOM HEATING PEAK LOADS Project Name Patten Res., Golf Cart Garage Date 4/8/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Golf Cart Garage Floor Area 210.0 ft2 'Indoor.Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = - = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof (R.38.2x14.16) 210.0 0.0430 44 397 Existing Walls 355.3 0.1020 44 1,595 Metal Door 88.0 0.5000 44 1,936 Double Mtl Tinted Default 28.7 0.8700 44 1,099 Slab-On-Grade pen .m = 46.0 0.7300 44 1,478 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 210 X Area another room 10.00 X 0.263 Height ACH Page Total /60] X AT, 6,504 = 431 TOTAL HOURLY HEAT LOSS FOR ROOM 6,935 PnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010-0408711:28:3. ID: Page 13 of 14. RESIDENTIAL -ROOM COOLING LOAD SUMMARY Project Name Date Patten Res. Golf Cart Garage 1 4/8/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Golf Cart Garage Outdoor Dry Bulb Temperature 112 OF Floor Area 210.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof (R.38.2x14.16) (N) 210.0 X 0.0430 X 77.0 = 695 Existing Walls (N) 88.0 X 0.1020 X 31.0 = 278 Metal Door (N) 64.0 X 0.5000 X 32.0 = 1,024 Existing Walls (S) 96.0 X 0.1020 X 38.0 = 372 Metal Door (S) 24.0 X 0.5000 X 43.0 = 516 Existing Walls (W) 171.3 X 0.1020 X 55.0 = 961 X X = X X = X X = Page Total 3,847 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (W) 0.0 X 46.6 + 3.7 K 134.2 = 496 Window (W) 0.0 X 46.6 + 4.0 fK 134.2 = 537 Window (W) 0.0 X 46.6 + 21.0 K 134.2 = 2,817 X x - x x - x x - x x - x x - x x - Page Total 3,851 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ_ = 920 Equipment 1.0 Dwelling Unit X 1,200 Btu = 1,200 Infiltration: 1.064 X 0.92 X 9.68 X 40 = 378 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,195 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ- = 800 Infiltration: 4,771 X 0.92 X 9.68 X 0.00467 = 198 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 998 EnemvPro 5.0 by EnemySoft User Number: 5862 RunCode: 2010-0408711:28:3 /D: Pae 14 of 14 BUILDINGENERGY ANALYSIS REPORT PROJECT: Patten Res:•MainJGarage 80512 Riveriera La Quinta, CA 92253 Project Designer: Design Build Structures, Inc 77980 Wildcate Dr. Suite #2 Palm Desert, CA 92211 760-772-0800 Report Prepared by: Gina Rose -Starkey EQS, INC 42335 Washington St. #F330 Palm Desert, CA 92211 760-674-234. CITY OF LA Q U I NTA ' r. i BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTI N I D DATE Job Number. , Date: 4/8/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. -his program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.enbrgysoft.com. 1.EqqrgyPro5.0_by.Energy;3ok. User Number 5862, Run Coale: 2010-0408711:17:2. ID; t TABLE OF CONTENTS .Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary. Room Heating Peak Loads Room Cooling Peak Loads IN 1- 2 3 8 11 12 13 14 EnergyOro 5.0 by EnergySoft Job Number: ID: 'User Number: 5862 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Patten Res. Main Garage Building Type m Single Family ❑ Addition Alone ❑ Muni Family ❑ Existing+ Addition'Alteration Date 4/8/2010 Project Address 80512 Riveriera La Quinta California Energy Climate ZoneTotal CA Climate Zone 15 Cond. Floor Area 425 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2. of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type 'Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-22 425 Existing Wall Wood Framed R-13 448 Existing Door Opaque Door /nsul 152 Existing Slab Unheated Slab -on -Grade None 425 Existing FENESTRATION U- Exterior Orientation Area(ft) Factor 'SHGC . Overhang S.idefins Shades Status HVAC SYSTEMS .Qty. Heating.Min. Eff Cooling Min. Eff Thermostat Status 1 None n/a Room PTHC without Sic 8.9 EER SetbacA New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Existing Main Garage Ductless /with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergryPro 5.0 by EnergySoft User Number: 5862 Run Code: 2010-04-08T11:17.2 /D: Page 3 of 14 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Patten Res. Main,.Garage Building Type m Single Family ❑ Addition Alone o Multi Family ❑ Existing+ Additio i/Alteration Date 4/8/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The erforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the.s ecial justification and. documentation submitted. HIGH MASS Design - Verify Thermal Mass: 425.0 ft2 Exposed Slab Floor, 4.000" thick at Existing Main Garage 0 HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed leted CF-4R form for _each ,of the measures listed below for final to be given. Ene Pro5.0 6". Ene Soft User Number: 5862 Run Code: 2010-04-08T11:17:2 - ID: Page 4 of 14 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Patten Res. Main Garage ❑ Multi Family ❑ Existing+ Add itic•n/Alteration 4/8/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 9.41 8.81 0.60 Space Cooling 137.93 130.27 7.66 Fans 25.25 25.25 0.01 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 172.59 164.32 8.27 Percent Better Than Standard: 4.8% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (tM 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (K9 200 0 Fuel Available at Site: Natural Gas (N) 200 0 Raised Floor Area: 0 (E) 0 0 Slab on Grade Area: 425 (S) 200 0 Average Ceiling Height: 10.0 Roof 425 0 Fenestration Average U -Factor: 0.00 TOTAL: o Average SHGC: 0.00 Fenestration/CFA Ratio: 0.0% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company EQS, INC Washington ashin ton St. #F330 NGina Rose -Starke ���� _482010 Address g Name y v `-� City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone 760-674-2345 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envElope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Design Build Structures, Inc l Address 77980 W/dcate Dr. Suite #2 Name / City/state/Zip Palm Desert, CA 92211 Phone 760-772-0800 Signed License # Date Erie Pro 5.0 by Ene Soft User Number: 5862 Run Code: 2010-04-08T11:17:2 /D: Page 5 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Patten Res. Main Garage Building Type m Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 4/8/2010 OPAOUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Roof 425 0.043 R-22 0 0 Existing 4.2.1-A6 Existing Main Garage Wall 48 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Main Garage Door 24 0.500 Insu/ 0 90 Existing 4.5.1-A3 Existing Main Garage Door 128 0.500 Insu/ 0 90 Existing 4.5.1-A3 Existing Main Garage Wall 150 0.102 R-13 1801 90 1 Existing 4.3.1-A3 Existing Main Garage Wall 200 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Main Garage Slab 425 0.730 None 0 180 Existing 4.4.7-A 1 Existing Main Garage Wall 50 0.102 R-13 225 90 Existing 4.3.1-A3 Existing Main Garage FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING. DETAILS . Window ID Exterior Shade Type SHGC H t Wd Ove hanq Len H t LExt RExt Left Fin Dist Len Hat Dist Ri ht Fin Len H t EnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010-04-08T11:17.2 /D: Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Patten Res. Main Garage Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/8/2010 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existing Altered Removed Volume Year Built Existing Main Garage Existing Main Garage 425 4,250 1988 Totals 1 01 425 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type. Status Existing Main Garage 1 None n/a Room PTAC without Sido 8.9 EER Setback New HVAC DISTRIBUTION System Name Heating Cooling Duet Duct Location R-Vaeue Ducts Tested? Status Existing Main Garage Ductless/ with F Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 0 Small Gas Kitchen Pipe Ins 40,000 50 0.53 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E(ft) E zr�w a Hot Water Piping Length o Q — System Name Pipe Length Pipe Diameter Insul: Thick. Qty. HP Plenum Outside Buried ❑ ❑ ❑ 1 ❑ ❑ ❑ ❑ ❑ EnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010-04-08T11:17:2 ID: Pae 7 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Patten Res. Main Garage Date 4/8/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Sumnary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled and installed according to ASTM El677-95 2000 when s e&ied on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opering of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air contrcl device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 1 12 c . §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indbated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is anclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Registration Number: Registration Date/Time: HERS Provider: EnergyPro 5.0 by EnergySoR User Number: 5862 RunCode: 2010-04-08711:17:20 /D: Page 7771 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Patten Res. Main Garage 4/8/2010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of JL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the W- hole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with t -ie Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no Icwer than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire o- exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens Shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling unix larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use rib more than 20 watts of power per linear foot of illuminated cabinet. Registration Number: Registration Date/Time: HERB Provider: EnergyPrc5.0 by EnergySoR User Number: 5862 RunCode: 2010-04-08T11:17:20 /D: Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Patten Res. Main Garage 4/8/2010 §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, ga-ages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed.low efficacy- luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requiremems of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in deta•:hed storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EKCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base• socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall •,omply with the applicable requirements of Sections 130 131 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildi cgs with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §1M9. Registration Number:. Registration Date/Time: HERS Provider: EnergyPro 5.0 by EnefgySoft User Number: 5862 Run Code: 2010-0408711:17:20 /D: Pae 10 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Patten Res. Main Garage Date 4/8/2010 System Name Existing Main Garage Floor Area 425 ENGINEERING CHECKS SYSTEM LOAD Number of Systems. 1 COIL CFM Total Room Loads 489 Return Vented Lighting Return Air Ducts Return Fan Ventilation 115 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK. COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 0 8,845 1,201 241 8,959 Total Output Btuh 0 0 Output Btuh/s ft 0.0 0 0 Cooling System 0 0 Output per System 30,600 4,895 2,241 115 5,385 Total Output Btuh 30,600 0 3,442 0 Total Output(Tons)2.6 0 0 Total Output Btuh/s ft 72.0 Total Output s ft/Ton 166.7 1 13,741 14,344 Air System CFM per System 1.100 HVAC EQUIPMENT SELECTION Airflow cfm 1,100 Fujitsu-30CLX 23,026 3,251 0 Airflow cfm/s ft 2.59 Airflow cfm/Ton 431.4 Outside Air % 10.5% Total Adjusted System Output 23,026 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,251 Arg 3 PM 0 Jan 1 AM Outside Air cfm/s ft 0.27 Note: values above givenat ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 65 OF Outside Air 115 cfm Supply Fan AL 1,100 cfm 70 OF 65 OF 105 OF — - Heating Coil 105 OF ROOM 70 OF ,COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/63°F 76/63°F 55/54°F Outside Air c 115 cfm AL Supply Fan Cooling Coil 55 / 54 OF 1,100 cfm _ 52.6% ROOM 72 / 61 OF 72 161 OF 4 EnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010-04-08T11:17:20 /D: Page 11 of 14 ROOM LOAD, SUMMARY Project Name Date Patten Res. Main Garage 4/8/2010 System Name Floor Area Existing Main Garage 425 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING P ---AK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM Sensible Existing Main Garage Existing Main Garage 1 489 8,845 1,201 489 8,845 1,201 241 8,959 load for zonal PAGE TOTAL TOTAL* Code: 1 489 8,845 1,201 241 8,959 489 8,845 1,201 241 8,959 ROOM HEATING PEAKIOADS Project Name Patten Res. Main Garage Date 4/8/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Garage Floor Area 425.0 ft2 Indoor Dr Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF .Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = = = = = = = = = = = = = = = = = 44 Btu/hr 0-38 Roof (R.38.2x14.16) 425.0 0.0430 44 804 Existing Walls 448.0 0.1020 44 2,011 Metal Door 152.0 0.5000 44 3,344 Slab -On -Grade perim = 60.0 0.7300 44 1,927 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 425 X Area another room 10.00 X 0.263 Height ACH Page Total /66] X AT 6,086 = 873 TOTAL HOURLY HEAT LOSS FOR ROOM 8,959 EnergyPro 5.0 by EnergySoft User Number: 5862 RunCode: 2010-04-08T11:17:2 ID: Pae 13 of. 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Patten Res. Main Garage 4/8/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Garage Outdoor Dry Bulb Temperature 112 OF Floor Area 425.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof (R.38.2x14.16) (N) 425.0 X 0.0430 X 77.0 = 1,407 Existing Walls (N) 48.0 X 0.1020 X 31.0 = 152 Metal Door (N) 152.0 X 0.5000 X 32.0 = 2,432 Existing Walls (S) 150.0 X 0.1020 X 38.0 = 581 Existing Walls (W) 200.01 X 0.1020 X 55.0 = 1,122 Existing Walls (SW) 50.0 X 0.1020 X 52.0 = 265 X X = X X = X J X I I= Page Total 5,960 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr X + X - X + X - X + Z - X + L - X + - X + X - X + X = X + X - X + X - Page Total 0 Internal Gain Btu/hr Occupants 4.0 -Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,200 Btu Infiltration: 1.064 X 0.92 X 19.58 X 40 = 766 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,845 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.92 X 19.58 X 0.00467 = 401 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,201 Enero7ro 5.0 by EnemySoft User Number: 5862 Run Code: 2010-0408711:17:2 /D: Pae 14 of 14