Loading...
06-1841 (SATT)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: '-106-00001841 `06-00001841 Owner: Property Address: -45245 SEELEY DR UNIT 15 A CP DEVELOPMENT APN: 604-040-999-2 -31116 - 77-564 COUNTRY Application description: DWELLING - SINGLE FAMILY ATTACHED PALM DESERT, C Property Zoning: TOURIST COMMERCIAL Application valuation: 71752 Applicant: Architect or Engin er: f -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affi un r penalty of perjury that ;Awn licensed under. provisions of Chapter 9 (commencing with tSection 70 0) of ;vision 3 of the Busi a rofessionals Code, and my License is in full force and effect. , ans CI ss: License o.: 728102 Date Contractor: NER-BUILDER DECLARATION here of rm under penalty of perjury tha exempt from the Contractor's State License Law for the - follow g reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT LA QUINTA, LLC CLUB DRIVE A 92211 Contractor: LENNAR HOMES OF CALIFORNI 40004 COOK ST. PALM DESERT, CA 92211 ,. (760)601-3100 Lic. No.: 728102 VOICE (760) 777-7012 ' FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/09/06 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided. for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. V_ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier OLD REPUBLIC IN Policy Number MWC11148SOO I certify that, in the performance of the work for which this permit is issued, I shall not employ any *:AILURE son in any manner so as to become subject to the workers' compensation laws of California, ag2plicant: if I s d become subject to the workers' compensation provisions of Section 0 bor shall forthwith omply with those provisions. Date: WAR TO SECURE WO K S' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINA ENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject 4ate: mit to cancellation. av read this application and state that the above information is correct. I agree to comply with all dinances and state laws re?e� struction, and hereby authorize representatives e r upon above-mentipection urposes. ignature (Applicant or Application Number . . . . . 06-00001841 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 513.50 Plan Check Fee 83.45 Issue Date . . . . Valuation . . . 71752 Expiration Date 11/05/06 Qty, Unit Charge Per Extension BASE FEE 414.50 ` 22.00 ---------------------------------------------------------------------------- 4.5000 THOU BLDG 50,001-100,000 99.00 Permit . . . MECHANICAL Additional desc . Permit Fee 70.50 Plan Check Fee 4.41 Issue Date . . . . Valuation 0 Ex*riration Date 11/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 51.69 Plan Check Fee 3.23 Issue Date . . . . Valuation 0 Expiration Date . . 11/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 1223.00 ---------------------------------------------------------------------------- .0300 ELEC NEW RES - MULTI FAMILY 36.69 Permit PLUMBING Additional desc . Permit Fee 136.50 Plan Check Fee 8.53 Issue Date Valuation . . . . 0 Expiration Date 11/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 13.00 6.0000 EA . PLB FIXTURE 78.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 LQPERMIT r - LQPERMIT Application Number . . . . . 06-00001841 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- i5.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 ;.a ---------------------------------------------------------------------------- Special Notes and Comments SFA (1,223 sqft) w/Porch (227 sgft). TOT Eligible. 75%REDUCTION TO PLAN CHECK FEES DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE 2001 CBC, CMC,.CPC, 2004 CEC, 2005 ENERGY CODES BLDG. 15A ------------------------------------------------------------------------- Other Fees . . . . . . . ART IN PUBLIC PLACES -RES 20.00 DIF COMMUNITY CENTERS -RES 56.00 DIF CIVIC CENTER - RES 157.00 DIF FIRE PROTECTION -RES 45.00 DIF LIBRARIES - RES 266.00 DIF PARK MAINT FAC - RES 16.00 DIF PARKS/REC - RES 669.00 STRONG MOTION (SMI) - RES "7.17 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid _ Credited --------------------------- Due ------------------------------ Permit Fee Total 787.19 .00 .00 787.19 Plan Check Total 99.62 .00 .00 99.62 Other Fee Total 2969.17 .00 .00 2969.17 Grand Total 3855.98 .00 .00 3855.98 John R. Hawkins Fire Chief Proudly serving t Unincorporated Areas of Riversid County and the Cities of. Banning Beaumont Calimesa o, Canyon Lake Coachella Desert Hot Spring Indian Wells e. - Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris Rancho Mirage San Jacinto Temecula 3oard of Supervisoi Sob Buster, District I 'ohn Tavaglione, District 2 im Venable, District 3 toy Wilson, District 4 4arion Ashley, District 5 RIVERS ME COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue . Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 Date (e City of LaQuinta Building Department �4 RE V The Rivers' C unty Fire Department is granting the Fire clear ce f the fol wing location Please call if you sl Id have anV questions 760-863-8886 Respectfully . By Terry DeSoucy 1 Fire Systems Inspector EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2d R., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 February 12, 2007 Mr. John Ewing Lennar Homes 40004 Cook Street Palm Desert, CA 92211 Re.: La Quinta Desert Villas — Building 15, Framing Subj.: Opinion of Construction Dear Mr. Ewing: Visits were made to observe the work and determine if it had proceeded in general conformance of the intent of the construction documents prepared by our office. Reports were provided to your firm detailing deviations from what the documents had intended and providing recommendations we had made to be implemented. Based on our observations, it is our opinion that the framing of Building 15 was constructed in general conformance with the intent of the construction documents prepared by our office. The content of this letter is understood to be an expression of professional opinion by this Costa Mesa, CA engineer which is based on his/her best knowledge, information and belief. As such, it consists of neither a guarantee nor a warrantee expressed. or implied. Modesto, CA If you have any questions please contact our office. Very truly yours, Pleasanton, CA BORM ASSOCIATES, INC. Roseville, CA Mohammad Douroudian Las Vegas, NV Director of Field Operations jh:1/10321 021207 Opin of Const Frm Bldg 15 Phoenix,Az distribution: (3) Addressee via. Mail (1) John Ewing via Fax (760) 772-8874 g$IONAL Tucson, Az (1) File 10321 QQ�F�c BAYAiII/�N�'���F Denver, CO '1 � o• 061301�� _ Beijing, PRC STATE OF �P� • .• Waildesign"'. Indorporated. DRYWALL * INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15A La Quinta Street Address City. Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation : Thickness R -Value Exterior Walls Insulation Type: Batts 3 1/2 13 Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts 0 Garage Ceilings Insulation Type: Batts 0 Interior Walls Insulation Type: Batts U - Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type: Batts Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0. Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with - the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where aplicable. 449739�- Walldesign, Inc. License Number Signature Date Insulation .. Subcontractor Waildesign' Incorporated DRYWALL * INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15B La Quinta Street Address City Riverside Lennar Homes Desert Villas 15 County Builder" - Project Lot Description of Insulation : Thickness R -Value Exterior Walls Insulation Type: Batts 3 1/2 13 . Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts p • Garage Ceilings Insulation Type: Batts p Interior Walls Insulation Type: Batts p Interm Ceilings Insulation Type: Batts p Garage Walls Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose p Blown Ceilings Insulation Type: Insulsafe p Declaration 1 hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where appli ble. ` 449739 Walldesign, Inc. License Number Signature Date Insulation • Subcontractor • Walidesign Incorporated DRYWALL * INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15C La Quinta Street Address City Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation : Thickness R -Value Exterior Walls Insulation Type: Batts 3 1/2 13 Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts 0 • Garage Ceilings Insulation Type: Batts 0 Interior Walls Insulation Type: Batts 0 Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 , Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where appli able. 449739 Walldestgn, Inc. License Number Signature Date Insulation • Subcontractor Walidesign Incorporated DRYWALL * INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15D La Quinta Street Address City Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation : Thickness R-Value Exterior Walls Insulation Type: Batts 3 1/2 13 Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings , Insulation Type: Batts 0 Garage Ceilings • Insulation Type: Batts 0 Interior Walls Insulation Type: Batts 0 Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration 1 hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where applicab e. W'z 449739 Walldesign, Inc. • License Number Signature Date Insulation Subcontractor Walidesign Incorporated ' DRYWALL * INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15E La Quinta Street Address City Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation : Thickness R -Value Exterior Walls Insulation Type: Batts 3 1/2 13 Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts 0 Garage Ceilings Insulation Type: Batts 0 Interior Walls Insulation Type: Batts 0 Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where appl' able. .. 449739 Walldesign, Inc. License Number Signature Date Insulation • Subcontractor . � Walidesign Incorporated Riverside DRYWALL * INSULATION * PAINT * PLASTER *CONTRACTOR 245 Seeley Drive 15F La Quinta Street Address City Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation : Thickness R -Value Exterior Walls Insulation Type: Batts 3 1/2 13 Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts 0 Garage Ceilings • Insulation Type: Batts 0 Interior Walls Insulation Type: Batts 0- Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where applicle..� q-n 449739 Walldesign, Inc. • License Number Signature Date Insulation Subcontractor �t Walidesign.'. Incorporated DRYWALL.* INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15G La Quinta Street Address City Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation : Thickness R -Value Exterior Walls Insulation Type: Batts 3 1/2 13 Flat Ceilings ^ Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts 0 Garage Ceilings • Insulation Type: Batts 0 Interior Walls Insulation Type: Batts 0 Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6; California Code of Regulations) as indicated on the Certificate of Compliance, where applicable. 449739 Walldesign, Inc. • License Number Signature ate Insulation Subcontractor Walldesign Incorporated DRYWALL * INSULATION * PAINT * PLASTER * CONTRACTOR 245 Seeley Drive 15H - La Quinta • Street Address City Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Interior Walls Description of Insulation : Thickness R -Value Exterior Walls Interm Ceilings Insulation Type: Batts 3 1/2 13 Flat Ceilings Garage Walls Insulation Type: Batts 12 38 Cathedral Ceilings Party Walls Insulation Type: Batts Insulation Type: 0 Garage Ceilings • Insulation Type: Batts 0 Interior Walls Insulation Type: Batts 0 Interm Ceilings Insulation. Type: Batts 0 Garage Walls '. Insulation Type: Batts 0 Party Walls Insulation Type: Batts 3 1/2 11 Blown Ceilings Insulation Type: Cellulose .- 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration I hereby certify that the above insulation was installed in the building at the above.location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where applicc�able.".�� 449739 ��'"'"�3 V— Walldesign; Inc: v License Number Signature Date Insulation Subcontractor FE9 15 2007 1:09 PM FR WALLDESIGN 949 251 9968 TO 917607728874 P.1e Walldetign - Incorporated DRYWALL * INSULATION * PAINTPLASTER * CONTRACTOR 245 Seeley Drive 15A La Quinta. Street Address City Riverside Lennar Homes Desert Villas 15 County Builder Project Lot Description of Insulation: Thickness R -Value Exterior Walls Insulation Type: Batts 31/2 13 Flat Ceilings Insulation Type: Batts 12 38 Cathedral Ceilings Insulation Type: Batts 0 Garage Ceilings Insulation Type: Batts 0. Interior Walls Insulation Type: Batts _ 0 Interm Ceilings Insulation Type: Batts 0 Garage Walls Insulation Type; Batts 0 Party Walls Insulation Type: Batts 31/2 I 1 Blown Ceilings Insulation Type: Cellulose 0 Blown Ceilings Insulation Type: Insulsafe 0 Declaration 1 hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficient Standards for residential buildings (Title 24, Pan 6, California Code of Regulations) ` as indicated on the Certificate of Compliance, where applica e. 449739 Walldesin, Inc. - _ License Number Signature Date Insulation Subcontractor y ., � •may' .. • t INSTALLATION CERTIFICATE (Page 4 of 12) CF -6R Site Address Permit Number 45245_Seeley_Drive_#1.5_a._,La_Quin.ta_CA 0 INSTALLER COMPLIANCE STATEMENT FORDUCT LEAKAGE INSTALLER COMPLIANCE STATEMENT The building was: ✓ Vested at Final V [ Tested at Rough -in INSTALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE:; ~ ❑ Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior finishing wall are properly sealed. ❑ If the house rough -in duct leakage test.was conducted without an air handler installed, inspect the connection points between the air handler and the supply and return plenums to verify that the connection points are properly sealed. j� jInspect all joints to ensure that no cloth backed rubber adhesive'duct tape is used XjNew Distribution system is fully ducted (i.e., does not use building cavities as plenums. or platforms returns'inlieu of- ducts). ✓ 11X_ DUCT LEAKAGE REDUCTION Prior' dUrPC for FPI/% UPriflea %an and dia¢naMfr hovii'nD ara;r AA/'AJ A-V_ DFU 2 NEW CONSTRUCTION: + Duct Pressurization Test Results (CFM @ 25 Pa) � Measured Signature: Date: 0_4/.27/o .Values 1 Enter Tested Leakage Flow in CFM: C37j Fan Flow: Calculated (Nominal: ✓ IT Cooling ✓ ❑ Heating)'or ✓ ❑ Measured 2 If Fan Flow is Calculated as 400 cfm/ton x number of tons or as 21.7 cfm/(kBtu/hr) x Heating 1. 0 C&nazity in Thousands of BtWhr output, enter total calculated or measured fan flow in'CFM heri: ✓ 3 Pass if Leakage Percentage!9 6% for Final or:— 4% at Rough -in: `pass ❑Fail 100 x r_37! Line # 1 ./ 1600 ine # 2)11 ALTERATIONS:.Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from Pre -Test of Existing Duct System Prior to Duct ; 4 System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM from Final Test of New Duct System or Altered Duct , 5 System for Duct System Alteration and/or Equipment Chane-Out.• Enter Reduction in Leakage for Altered Duct System, 6 Line # 4 Minus(Line # 5 —(Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) Entire New Duct System - Pass if Leakage Percentage S 6% for Final 8 100 x ine # 5 / Line # 2 ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change - Out Use one of the following four.Test or Verification Standards for com liance`,, 9 Pass if Leakage Percentage S 15% [ 100 x [ (Line # 5) / (Line # 2)]] ❑pass ❑Fail 10 Pass if Leakage to Outside Percentage S 10% [ 100 x f ...(Line # 7) / (Line# 2)]] ❑,Pass ❑ Fail Pass if Leakage Reduction Percentage >: 60% [ 100 x L_(Line # 6) / .. (Line # 4 )]] 11 and Verification b Smoke Test and Visual Inspection ❑Pass 0- Fail rC2 Pass if Sealin of all A►ccessibleLeaks and Verification b Smoke Test and Vis ` dl I ection ' ❑ Pass 13Fail Pass if One of Lines # 9 thyVpph # 12 pass ❑ Pass ❑ Fail ✓°[, the undersigned, verify that the above diagnostic test results were performed jn conformance with the requirements for compliance credit 1, the undersigned, also certify that the.newly installed or retrofit Air -Distribution System Ducts, Plenums and Fans comply with Mandatory requirements specified in Section 150 (m) of the 2005 Building Energy Efficiency standards. Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner a Team.AirX_Heating Signature: Date: 0_4/.27/o Copies to: BUILDING DEPARTMENT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPANCY Residential Compliance Forms' September 2005 INSTALLATION CERTIFICATE (Page 5 of 12) CF -6R Site Address Permit Number -452Drive_#_15-a,La_Quinta_CA ✓ CX] THERMOSTATIC EXPANSION VALVE (TXV) Procedures for f eld verif cation of thermostatic expansion valves are available in RACM, Appendix R1. ✓ ✓ ✓ 0 REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Charge and Adequate Airflow for Split System Space Cooling Systems without Ti&rmnafnfir. Fxnnnainn VnlvPa Outdoor Unit Serial # OF Location Access is provided for inspection. The procedure shall Outdoor Unit Make OF Outdoor Unit Model OF Cooling Capacity consist of visual verification that the TXV is installed on Date of Verification OF ✓ IR—jYes ❑ No the system and installation of the specific equipment [X] shall be verified. Yes is a pass I Pass I Fail ✓ 0 REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Charge and Adequate Airflow for Split System Space Cooling Systems without Ti&rmnafnfir. Fxnnnainn VnlvPa Outdoor Unit Serial # OF Location OF Outdoor Unit Make OF Outdoor Unit Model OF Cooling Capacity Btu/hr Date of Verification OF Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charee Measurement Procedure (outdoor air dry-bulb 55°F and above): Procedures for Determining Refrigerant Charge using the ,Standard Method are available in RACM, Appendix RD2. Note: The system should be installed and charged in accordance with the manufacturer's specifications before starting this procedure. Measured Temperatures Supply (evaporator leaving) air dry-bulb temperature (Tsupply, db) OF Return (evaporator entering) air dry-bulb temperature (Tretorn, db) OF Return (evaporator entering) air wet -bulb temperature (Treturn, wb) OF Evaporator saturation temperature (Tevaporator, sat) OF Suction line temperature (Tsuction, db) OF Condenser (entering) air dry-bulb temperature (Tcondenser, db) OF unerheat Charee Method Calculations for Refrieerant Charee Actual Superheat = Tsuction, db — Tevaporator, sat OF Target Superheat (from Table RD -2) OF Actual Superheat —Target Superheat (System passes, if between -5 and +5°F) ­ 3 OF Temperature Split Method Calculations for Adequate Airflow Rnlit MPthnd 4ralculatinn is nnt nPr_escary if,4dPauatP .4irtlnw r_radd is takpa Actual Temperature Split = T return, db Tsupply, db OF Target Temperature Split (from Table RD3) OF Actual Temperature Split Target Temperature Split (System passes if between - 3°F and +3°F or, on remeasurement, if between -3°F and -100° O. Residential Compliance Forms April 2005 11. INSTALLATION CERTIFICATE Site Address 4.52.45–Seeley_Drive_# 1.5_a —La_Quinta_CA 6 of 121 CF -6R Per mit.Number 0 ' .. SmndardCharge Measurement Summary: 3ysiennAalIpass both ref rigerantcharge and'adequateairflowcalculition,ormriaafrom:4hesame measurements. if correjcti ve actions vrerelAm, both• criter ism wn be• remeasured and recalculated., WYes 10 No 3yslem Passes Aller nate Ch arge Meas uremen i Prosed u re (outdoor ai r dry=bulb`belovr 55 T); Note; The system should be i natal led and charged in accordance yr rite the ma n ufac[urer's specifications and i nab I 1--rver i fication she I I be documented on CP -6R before ata rti ng th is pracedLiie, if outdoor air dry-bulb is 55 °Er or- above., insia Her steal I use the 3m ndard Charge Measure P rocedure: P,aoedIllef fo, DelelAdlt tg Ref,;geia CAu ge'xsi*g like Alfe„eale Method a;e auaikble i,e RA W.;App egad x RD3 Weigh-inCharpinkMethodfor Ref rikerantCharke Actual liquid line length: ft Man ufaoturer'e 319 ndard I iquid I ine length: ft Di ffemnce(Actual'–Slandard): ft Man ufacturer'scorrec(io_n (ounces per foot) . 'x•difkreace' in' length = ounces (+ = add) { remove) rleasured• Ai rf lour Method" for uatg Ai rflovr Teri fkation au+ll&bk i,c RA CU -A .t RD2. d CalculatedAitflow: Cool ingCapacity{Btu/h.r) X0.033(cfrcJB1u-h r)= CpM Measured Airfbvr is` CPM(Measured airflow mus[begreaterAhsn the calcula[edairflow). Alter nate Cha rge Measurement 3 umma ry: 3yaiem steal I pass bath refr igera nt cha rge and adequate a it flour calculatic .cr iteria fr 'the sa me measurements. If correcti veactions vremtaiaen both criteria mus[beremeaauredandrecalculated. V 10 Yes 10 No I S slew¢ Passes InstalIing3ubeontractor (Co. Nerve) OR General Contractor (Co. Name) OR avrner Heating &Air Conditioning Inc. Signature;_ Date:.'` 0_4/ 0.77 Copies W: BUILD WGDSPARTMtiJVT,HERS RATER (IF APPL[CABLE}BU[LDWC�GWN�RATOCCUPA"NCYE Re9deAu d G2i*pA ,ece Forney` 2DDS" INSTALLATION CCRT[ R[CATE (Pa e7orm) CF=6R ' Site Address Pet mit Number 4.5245_Seeley__Drive_#1.5=a__.La_Quin.ta_CA MISCELLANEOUS CREDITS Ive 13 DTACNOSTTC SMLY DUCTLOCATiON, SURFACE AREA AND RNALUE Pmceubms f rjm[d ws iSicmion and diagsaslic Jeslingfer Ais 9map ccraP1hhC& CMd.0s aux aaaffa6de in A4 CU. i0f ppienda RC, Rf do 14H. i ❑ LESS THAN 12 LINEAL FELT OF SUPPLY DUCT OUTSTDL OF CONDPITONED'SPACE COMPLIANCE CREDIT ❑Yes I ❑NO I Laos than 12 l Local root a rsupp ly duct cat kin a rcanditianed space. Yee tothiscomplianoecredit isap®sa of ❑ Pass. ✓ ❑Rail ✓ 0 SUPPLY DUCTS LOCATFD TK CONDITIONED SPALL CONIPLTANCE CREDIT ✓ ❑ Yes • ❑ NO I D ucts aro lacated w Rhia the canditiaaedval ume a rb ui Iding, -- Yes ioill iscomplisnce.credit- isapass ✓• ' ❑ Pass .I 0 -Pail ret System lkslgo wHflc atiou 1s required for a oompliauoe credit for: the followiv2: 1_ Supply duct surface area reductio I. Buried supply ducts on the oeifluq 3. Deeply burled supply ducts : 0 DUCT SYSTEM DESTCN VERTFTCATION. ,i ❑ Yes ❑ No A --ale a it flour mi fieri ✓ 13 Yes ❑ No Thedurnsyslem design plan meets the requirerrenisapecifled in*RACM; Appendix RE, Section RB.4.2 ve ❑ Yea ❑ NO Tbeducteyslemdesign plan eximson building plana: se ❑Yea ❑ No' DuCtsi2ea,ductsyslem layout andlocationsofeupply& return registm nnatcb.tlreductsystem deli n plan Yesto'alI is Pasi V ❑ Pass ❑Pail f u SUPPLY DUCTS SQRFACE AREA REDIICTTON COMPLIANCE CREDTT O BURIED DUCTS ON THE cuumC COMPLTANCL CREDIT ❑Yea ❑ No-BuriedDucisontheCeiIin ❑ Yea ❑ No I Verifie lRigb Insulation 1nslallation Quality " Yea to dur-t eyviem design, sa I' duct surf"- a rea reduction and.lh L? com I is noe. credit is apan ' ❑ Pass ❑ gai I ve 0 bRY-PirY BIIRTRTi bII[TS CnMPLTANCLCRRflTT we ❑ Yes ❑ No Deeply Bur ied D ucw ❑ Yea ❑ NO SLLrIke - Yes to duct system design, impplyduzisurfamarea reduction and th is com Iiancecredit is.a paes Pass ' ❑ Pail 000000®�®— 0000���®��� . _ : for : - O BURIED DUCTS ON THE cuumC COMPLTANCL CREDIT ❑Yea ❑ No-BuriedDucisontheCeiIin ❑ Yea ❑ No I Verifie lRigb Insulation 1nslallation Quality " Yea to dur-t eyviem design, sa I' duct surf"- a rea reduction and.lh L? com I is noe. credit is apan ' ❑ Pass ❑ gai I ve 0 bRY-PirY BIIRTRTi bII[TS CnMPLTANCLCRRflTT we ❑ Yes ❑ No Deeply Bur ied D ucw ❑ Yea ❑ NO I Veri fied High Insulation Instal lation Qual ity . 1 ,I Yes to duct system design, impplyduzisurfamarea reduction and th is com Iiancecredit is.a paes Pass ' ❑ Pail Copi4i W: BU ILD LNG DMPARTMSFIT,HMRS RATER ffAPPLICABLE) BU ILD INGOWNSRATOCCUPANCY. RegdeAfjW CompUa ece Fo na April 2DDS q . s. � s INSTALLATION CLIITIFIC ATE (Pae a of 12) CF=6R SiteAddresa Permit Number _4.5245_Seeley Drive_#1.5=a—La_Quinta_CA Q ✓D FAN WATT DRAW Pro eedwerfor meacupiAk Ike air kaA&e, waor draw a►e a Laibbk i,e RA QV, Appepbdu R$3. 2. se 112etbod For Fau Watt DrawMeasuremeot ❑ RE3.2.1 Portablewatt Meter Measurement ❑ RE3.2.2 Uti lit -i Revers ue Meer Measurement Measured Fan WattDraw Meaanred Ran Flow .enter total cfm from airflow'verification E nur. results of Wattdofm' Trate: 0_4/ 0'77 1 O RE4.1.1 Diagnostic Pa n F low Uri ng Floor Capture Hood ❑ RE4.1.2 Diagnostic Ra n F low Usi ng Plen um Pressure Match in ✓ ❑ Yea ❑ No Measured fa n.watt/cfm draw is equal toor. .lower than. the fan watUcfm draw documented in CF -IR ❑. ❑ 4 r E3 Yee E3 No Cool i ng capacities of i nata Iled ayA*ff a re S to max Iln La cool in Measured'Ai rf low: Yes fs a ass Pass. .Rai l Ve 0 ADEQUATE AYRFLOW VERTFTCATTON PXhtedw esfornwasuriq Ike avf7orrare aua;la&eiA RA CX Appaobd;x-RE3. L +r Metbod For Airflow Measurerneut Tears Heating 8r Air Conditioning Inc, g Praeedxres , delerneiRi' rRaxinbriR molixgl6ad 44pawy are aua;lable 0e RA CU Apfiepbdix RF3. Trate: 0_4/ 0'77 1 O RE4.1.1 Diagnostic Pa n F low Uri ng Floor Capture Hood ❑ RE4.1.2 Diagnostic Ra n F low Usi ng Plen um Pressure Match in ❑ RE4.13 Diagnostic Pa n F low Uzi ng Flow Grid hlJesaurernent ❑ Yea ❑ No Duct design exist on plans 3 +r ❑ Yes ❑ No Dunt lealmge reduction credit verified 4 r E3 Yee E3 No Cool i ng capacities of i nata Iled ayA*ff a re S to max Iln La cool in Measured'Ai rf low: cit indicated on the Performance's CP -IR and RF -3. Rated Tonscfm/bn T the cool ing capacities of instal led'systeMsare>- than maximum 5 .r 13 Yes ❑ No ,r 1 %r O Yes ❑ No Measured airflow is greater than thecriteria in Table R&2 inatal leds memuslbe5toelettricalin titin -the CP- IR.. Yesis a P an ❑ .Pass ❑ Rail watts cfm wattslcfm Total Of m cfmAon +� 0 mAXTMUl14 CJ7OLYNC CAPACYTY Tears Heating 8r Air Conditioning Inc, g Praeedxres , delerneiRi' rRaxinbriR molixgl6ad 44pawy are aua;lable 0e RA CU Apfiepbdix RF3. Trate: 0_4/ 0'77 1 1 V ❑ Yes 13 No Adequate airflow verified( eMequateairfbwcredit), 2 V ❑ Yes O No RefrigerantchargeorTXV 3 +r ❑ Yes ❑ No Dunt lealmge reduction credit verified 4 r E3 Yee E3 No Cool i ng capacities of i nata Iled ayA*ff a re S to max Iln La cool in cit indicated on the Performance's CP -IR and RF -3. T the cool ing capacities of instal led'systeMsare>- than maximum 5 .r 13 Yes ❑ No cooling capacity in theCR-1R, then°theelectriral input for the. inatal leds memuslbe5toelettricalin titin -the CP- IR.. ❑ ❑ Yes b 12 and 3,,a nd Yes to either 4 or 5 is pass 11 Pass Fail AfCYT TIER AYR CJaNDMONER P,a,oe&Uer r wri ,eal;edare avalabie i)tRACX A x Rl. 1 V ❑ Yes ❑ No I BER values of instal led syaV.ma match tbeCF- 1R w' 2 ❑ Yea ❑ No For split m indoor coil is matched to outdoor ooiI' 3 ✓ ❑ Yes O No T ime Delay ReJay `Leri Pied 0 f Required) ❑ ❑ Yea to I and 2• and3 f Requirpd ivapaSsPassI Rail instal I ing 3 uboontractor (Co. Name) OR General Contractor {Co. Name OR Owner A Tears Heating 8r Air Conditioning Inc, g Signature Trate: 0_4/ 0'77 1 Go pick Lo: BUILD [NO DEPARTMENT, H MRS RATER (IF A PP L[CABLS'} BU [LD LNG OWN MR AT OCCU PANC V Re9de,e W Cantp. artee Fornu April 205 4 i. INSTALLATION CERTMCATE (Page 3 of. 12) CF -6R Site Address Permit Number _452.4.5_Seeley Drive-#1-5-a—La_Quinta-CA An installation certificate is required to be posted at the building site or made available for: all appropriate inspections. (The information provided on this form is required) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(a). HVAC SYSTEMS: Heating Equipment Equip Type (pkg. heat um CEC Certified Mfr. Name and Model Number # of Identical Systems. Efficiency1. (AFUE, etc.) 2CF-1Rvalue Duct Location • alti etc. Duct or Piping R -value. Heating Load Btu/hr Heating Capacity Btu/hr Sp ttlttl HP + Coi7 Adp ) n 80 0 / A�� = f4F0 070 4 000 14-86-05 Cooling Equipment Equip Type (pkg. heat um CEC Certified Mfr. Nameand Model Number # of Identical Systems Efficiency (SEER or EER) 2CF-1R value) DudDuct Location attic etc. Duct R -value Cooling Load. Btu/hr Cooling Capacity Blu/hr SPlit_HP Coil iB Ell El -370 AAS 1-61 4.8 000 14-86-05 1. > symbol reads greater than or equal to what is indicated on the CF -IR value: Include both SEER and EER if compliance credit for high EER air conditioner is claimed.. 11, the undersigned, verify that equipment listed above is: 1) is: the actual equipment installed, 2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1R) submitted for compliance with the Energy Efficiency Standards for residential buildings, and 3) equipment that meets or exceeds the 'appropriate requirements for manufactured devices (from► the Appliance Efficiency Regulations or Part 6), where applicable. Installing Subcontractor (Co. Name) OR General c Contractor (Co. Name)4OR Owner iLearn.Air_&_Hea.ti g7 Signature: Date: 04/ 07 Copies to: BUILDING DEPARTMENT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPANCY. Residential Compliance Forms April 2005 MAY -02-2007 WED 10:44 AM TEAM CWTEFCCAT9OF FIRLD VE MI6ICATION & Desert Villas Tract 30830'Lbt 15A La Quinta Cntact Installing Contractor Signature .ally sinned FAX N0, � 951 676 2774 P. 02/21 rllc TI?,sT, o (page i offf),- Uuilder Name t_ennar Homes I ago Ian Number 1 hone Saml5leGrompl4umbei 3 28 CdimsteZone 15 1Da12 gamplel�ouxeTtumb2,r 12 Firm CPl3CA Enalasys Corp Street Address: Cityetip: SOC toAve Calexico A 92 3 uptes to: BUFLDFR, HERS P'ROVTDER AND ItU LD1NNG WrIPARTMENT HERS RATBEt COMPLIANCESTATILKERC' The hoLuc was: '0� ❑ Testtd yr XJ Appmvodespatiafeamplc Leaft but was not leatad As 1be.RIM rater providin$ dtagnoatlictestingand feld verrfic�iion t certify Uratthe"ouae Identified on this form compiler urilh the diggn� Lic tealed comp) fiance rea(ai remenls air c1!wbed tan this farm . lie MS raver muffL decks nd 4eri fyy_ that the nes distribution system is fully dusted and cwrecttape is wxAUforea CR -AR may be relessad on every leered buAdrng TheHBR.4 raw must not nrle%etheCR4R until a properly eompleledandrigned CO -61K has been received for thesampleand seated but ldings. 13 The inslaIter twpro4ided a campy ofCF-R (inrlalletian CertiOc ej. ❑ NeaAiatribution system is fully dur�eel(.e, d,�not uae•building cavities asplenums or platform returns in lieu afdu,ets'j. O New sysleTm when cloth baaW, rublroT adhcaive dual laps in inaLal W, mastic and draurban& arc Lmed in c4mbinafim with Cloth beaked, -rubber adhe4 ve duct Lapp la seal Icalm at dust connxtians. V r MiNFKUM RFQMR.EKEj4TS FOR DUCT I.. AKAGB R't DUC nON C.IOMP` UNCE CRL.DIT pAww&ur ,ewAM wgSeafia,e &Ad d,'ag eosi c lair;,egc;Jmidislribul;Q,esyat"sftye &jditabte ye RACK Appe*&xRC4.3. Red,:M rtat CarKpbaAce Faero gyp.,, ,- Certificate of Occupancy.,-- Td4 Ihcoaonnim�Cy _ y�O Y p OF9ti : M . Building & Safety Department ' 9► This Certificateis issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in= compliance with the, provisions of the Building Code. and the various ordinances of the City regulating building construction and/or*use. BUILDING ADDRESS: 45-245 SEELEY DRIVE (UNIT #15 -AY. ; Use Classification: SFA 4 Building Permit No.: 06-1841 Occupancy Group: R-1 r Type of Construction: VN - Land Use`Zone: CT Owner -of Building: ' CP DEVELOPMENT LA QUINTA, LLC Address: 77-564 COUNTRY CLUB DR: #100 City, ST, ZIP: PALM DESERT, CA 92211 y By: STEVE TRAXEL _ Date: MAY 24, 2007 Building Official ; POST IN A CONSPICUOUS PLACE