0111-0019 (ELEC)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
"-Date%"' -f- IC&- Signature of Contractor'`
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
N(i ) I have and will maintain workers' compensation Insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
aT.t� i'1.s FUND lb34it5"d
(This section need not be completed if the permit valuation is for $100.00 or less).
() I certify -that in the performance of the work for which this permit is issued,
I shall not"emplloy/any,person in any/Ma (en so as to become subject to the
workers' corApensatlon laws of California; and agree- that .if I ish.ould become
subject to the workers' compensation provisions of Section 370b of the Labor
Code, -I shall forthwith comply,with-those pprovisions?
Date- ir...rb Applican`t`f�
Warning: Failure to secure Workers' Compensation cove ra emis-unlawful'and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above mention ed�property�Jfor'i�nsspection purposes.
7 ! l,� / - ' Date 1� �,a..
Signature (Owner/Agent) -
BUILDING PERMIT PERMIT#
DATE l' / VALUATION I LOT (jl11-019 TRACT
�I
.00T)M
JOB SITE
APN
ADDRESS
6-t'.St9£} Al:!lM S STR.UFF
OWNER
CONTRACTOR / DESIGNER / ENGINEER
LA Ltit37'A 2-113nC LLCI
JTTN11Y Cl:ib6BANY
37-55 WUM MARCH LICE
i W 1Q16T W'MAT, UJOIArAY 1, 60
l c"K'3YJki CA 95129
)_�LA.0797Lk CA 9200
(714)528-881 3 03iI1 1569
USE OF PERMIT
G (J:h OM- CXAL �
SPRINT CELL, SITE PER A.PPR.OViota K.&NS CUP 417001.0631
V �.I.,sa,Ei'I')�i7 ty 1S RIA 1.9
6 '0 j', '91f'.Al..l,, i;3.bt1 LIr
1+ISTROA' IO) d;'OSIZ(Ar (:i)M.s",f.:3.d►J4:".3'tf"alw
PER W. J., TIVER 9MMARY
SLEC'.TRICA1.,Ni, . $33.50
r
;11-;A-7`€i°3'AL c:ONRI'RLc, !YON AND PLANC111,r.s�.
$826.80
FEB 0 8 2002
C9'Irlf CWL QLIII►l
I IIIII�I �III� I I �IIII IIII 36
r
- —
RECEIPT
DATE
B �%
DATE FINALED
INSPECTOR
INSPECTION RECORD
OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR
BUILDING APPROVALS MECHANICAL APPROVALS
Set Backs Underground Ducts
Forms & Footings Ducts
Slab Grade Return Air
Steel Combustion Air
Roof Deck Exhaust Fans
O.K. to Wrap F.A.U.
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
"Drywall - Int. Lath
'
Final
Final
POOLS - SPAS
BLOCKWALL APPROVALS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
I
I
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS.
Temp. Power Pole .
Underground Conduit
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Notice
LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and(ny License is in full force and effect.
License # Lic. Class Exp. Date
'1 .155 /' _ e/. t, t..'^ 1 I }f.�_j lisp/�. tj%:1'.•t
Date f ' Signature of Contractor' -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( )'I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
() I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the, Labor Code, for the
performance of the work for which this permit is issued'
,( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier ` `,, Policy No.
. I F i• :- {ti it,^7 l.` iV�:uiyafi
(This section need not be completed if the permit valuation is for $100.00 or less).
() I certify that in the performance of the work for which this permit is issued,
I shall not employ any.pgrson in any�•hnanner so as to become subject to the
workers' con`Ipensation laws of Califbrnla, and agree that •it I/`should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code,) shall forthwith comply.-with,those�povisions=,
Date~ Applicant
Warning: Failure to secure Workers' Compensation coverage-•is-unlawful*and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section=3706 {
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety/
for a permit subject to tHe, conditions and restrictions set forth on his
application. -- - — -
1. Each person upon'whose behalf this application is made &each person at ~'
whose request -and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to'cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above -mentioned property;fo;:inspection%;purposes.
Signature (Owner/Agent) r" ` — Date
BUILDING PERMIT PERMIT#
DATE f VALUATION LOT ? 1 : j!? i:� TRACT
JOB SITE
APN
ADDRESS
OWNER
CONTRACTOR / DESIGNER / ENGINEER
.i;h.T".. ."..,�:..YI
:.i:. i.'ti., 3:,,•3;'`.::z':' ''rf`.i? '`^r,`f r-
USE OF PERMIT
.,'�ied1'•%;' >}v.•_)�'v'v:",...._.. ... ,...,..'.ii �)•:. Pi , ri•...� ,"Ler )':`-.. - �!�' Ft;'.>� `L'.i::.
/ �� gyp, llJ '• '?:.°r�
lFiv,l�;.��::.,.{�,',
,`4
I
QY
Di� �'l )'9',�? _''.7�•��'v,.h�.' �?•i'�!ij _;i+it ;}�f i;'ct
:60 (%_
fi..,'icr��'.ian
FEB' 0 8 2002
WYOR aQUIRA ,
RECEIPT
DATE j
ey..-: _
DATE FINALED
INSPECTOR
1TSA�
S/
75-120 n
X
I
SSG Z
r71 �2b C.ol;.Q C-«-
LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # . Lic. Class Exp. Date
719304 AB C-10 FlIC 02/28/2(
Date Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier STATE FUND Policy No. 1634953
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
Date: Applicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnity
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
Correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the,above-mentioned property for inspection purposes.
Signature (Owner/Agent) Date
A\
BUILDING PERMIT PERMIT# c
DATE VALUATION LOT 0111-019 TRACT
$65,000.00
JOB SITE
APN
ADDRESS 46-600 ADAMS STREET
649L020-054
OWNER
CONTRACTOR / DESIGNER / ENGINEER
LA UINTA 2-SPC LLC
JITNEY COMPANY
3255 WEST MARCH LANE -
1057 EAST IMPERIAL • HIGHWAY #605
STOCKTON CA 95129
PLACENTA CA 92670
(714)528-8813 CBL4 6569
USE OF PERMIT
COMMERCIAL
SPRINT MONOPALM CELL SITE PER APPROVED PLANSlCUP #2001.063:
VALUATION 62,925.00 LS
6 FT. WALL 83.00 LF
E911MATED COST OF CONSTRUCTION
65,000.00
PERMIT FEE SUMMARY
PLAN CHECK FEE 101-000-439-318 $313,30
CONSTRUCTION FEE 101-000-418-000 $482.00
ELECTRICAL FEE 101-000-420-000 $33.50
SUB -TOTAL CONSTRUCTION AND PLAN CHECK
$828.80
LF93 PRE -PAID FEES
$0.00
TOTAL PF'RMIT FEES DLTE NOW
$828,80
9 1IIIIIIIIIIIIIIIIIIIIIIII
37
IE
T
RECEIPT
DATE
BY
DATE FINALED
INSPECTOR
City Of La Quinta ,
Developers Project Approval Form
Prior to the issuance of Building Permits for the project listed below, the following Departmental
clearances must be obtained. Please return this form to the Building and Safety Department only
after approval. Contact applicant for resolution of conditions preventing or delaying approval.
Project: 571 S.F. Sprint Unmanned Cell Site
46-600 Adams Street
Applicant Contact: Gene Enarson 949-307-8807
Application / Circulation Date:
Community Development Department
Christine di Iorio, Planning Manager
Public Works
Steve Speer,
7 2 01 ER<f2—
Date
III V1 k 22
Date
6 7'
D to
r
#
GtY Of La Quinta
Building 8r Safety Division - SCANNED
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address:
A31445 5r Z4 &)t)1A
Owner's Name: Z/-C
A. P. Number: Z-D -
Legal Description:
C
Contractor. 7qq,,,C,2 17-Alfy
Address:
City, ST, Zip: TvrV4?-1 7— ... .
Telephone: -Al_-Al_ ISOO x ) I k
--7
Address:
City. ST, Zip:
Project Description:.5
Tel
State Lic. 3 Y
City Lic.
Arch.. Engr.. Designer:
Address:
City. ST, Zip:
Telephone:
Co ristruction Type: OccupancN
. . . . . . ......
State Lic.
P ect type (circle on Ne%v Add'n Alter Repair Demo
Name of Contact Person: Sq.:Ft:.::55:7ZJ#:S7tories: # Units:
Telephone # of Contact Person: q-'I� 3,07 Estimated Value of Project:
fgo - 7 - 1 66-, boo
10-7 APPLICANT: - LICANT: DO NOT WRITE BELOW THIS LINE
Submittal
Req'd
Rec'd
TRACKING I
PERMIT FEES
Item Amount
Plan Sets
2-
Plan Check submitted
IYZ
Structural Calcs.
17) —
Reviewed, ready for corrections
tAfelan
Check Deposit
Truss CaIcs.
Called Contact Person
V'o
Plan Check Balance •
B.I.,
PIEE
Title 24 Calcs..
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
—
Grading plan
Subcontactor List
2"' Review, ready f or correct ion issue
Called Contact Person
Electrical •
Plumbing
Grant Deed
Plans picked up
S.M.I.
—
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for corrections/issue
Developer Impact Fee
A.I.P.P.
—
Planning Approval
Called Contact Person
Pub. Wks. Appr
Date of permit issue
School Fees
:/d
b
I
0 /
<? (
Total Permit Fees
I
Cio of La Quinta
Developers Project Approval Form
Prior to the issuance of Building Permits for the project listed below, the following Departmental
clearances must be obtained. Please return this form to the Building and Safety Department only
after approval. Contact applicant for resolution of conditions preventing or delaying approval.
Project: 571 S.F. Sprint Unmanned Cell Site
46-600 Adams Street
Applicant Contact: Gene Enarson 949-307-8807
Application / Circulation Date:
Community Development Department
Christine di Iorio, Planning Manager
Public Works Department
Steve Speer, Senior Engineer
1172 01EA�X—
Date
Date
Date
YOUNG ENGINEERING SERVICES
Engineering Architecture•Surveying• Building &.Safety Services
Letter. of Transmittal
To: City of La Quinta
Attn: Greg Butler
Tel No.. -
We are forwarding: By Messenger
No. of Copies
1
Description:
Plans
Date: 11/8/01
Project: PC #0111-019 (1" check)
46-600 Adams St.
W.O..
Tract No.:
By Mail X Your Pickup
Monopalm shop drawings
Monopalm column/baseplate/caisson calculations
Soils Report
Comments: Structural plans and calculations are approvable
This Material Sent for:
Your Files X Per Your Request
Your Review Approval
Checking At the request of:
Other
By: John W. Thompson
Phone # 760-342-9214
47-159 Youngs Lane, Indio, CA 92201 (760) 342-9214
Bronz Young
0
TA'i
Building & SC
Of
Plan Review
Date: 11/16/01
Project Address: 46-600 Adams St.
Project Description: Sprint Cell Site & Mon,
Status: First Plan Review - Noi
Contractor/Applicant: Undetermined / Gene
Plan Review by: Daniel P. Crawford Jr.
Building Inspector H
(760) 777-7027
APPLICANT:
The following items are being returned
to you for correction:
1. Two (2) plan sets
Dear Gene,
The following instructions are provided to expi
* Provide a written response to each comment
the correction can be found.
* Show or note specifically how compliance w
* Please return all red =marked plans and/or call
a"
Department
Correction List
Permit # 0111-019
son 949-307-8807
BUILDING DEPARTMENT STAFF:
DO NOT accept any resubmittal unless
ALL of the following items are included:
1. Two (2) plan sets
to your plan review for approval:
the following pages, noting specifically where
a code requirement is achieved.
itions with your resubmittal, Thank You.
1. Provide written evidence of Community Development Department approval of this Project.
Contact the Community Development Department directly at (760) 777-7125.
2. Provide written evidence of Public Works Department approval for this Project. Contact the
Public Works Department directly at (760) 7771-7075.
3. Provide written evidence of Riverside Coun' Fire Deparhnent approval for this Project.
Contact the Riverside County Fire Department�directly at (760) 863-8886.
4. All documents prepared by a licensed architl' ct or: engineer shall be stamped and wet -signed as
prescribed by the California Business and ProfIssions Code 5536.. Digital signatures are not
acceptable. (Sheets LSI, LS2, El, E2, & E3)
5. Note on Plans: "All construction shall
Mechanical, and Electrical Codes.
6. Noted emergency generator parking as pi
access hardships for adjacent dedicated RV
with the 1998 California Building, Plumbing,
I creates a circulation obstruction as well
spaces. Provide specific approval from listed.
departments noted above, line 1, 2 & 3 for 1
7. Submit structural calculations to support
Detail notes 5'-0" minimum footing width,a
8. Provide Contractor information.
9. Cellular Tower structural is approved
Please revise plans and/or calculations as nevi
plans and/or calculations, stamped and wet-si,
further information is provided and reviewed,
if I may be of any further assistance, Thank yc
Since ely,
ante . ra or r.
Building Inspector II
dpc
1
iosed generator parking.
posed 6' CW perimeter block wall, detail 1/C6.
e grade 8". Reconcile.
reprint and resubmit two complete sets of:
by the professionals who prepared them. As
tional corrections may be required. Please call
YOUNG ENGINEERING SERVICES
Engineering Architecture -Surveying- Building & Safety Services
Letter of, Transmittal
To: City of La Quinta Date: 1/29/01
Project: PC #0111-019 (1" check)
46-600 Adams St.
Attn: Greg Butler W.O.:
Tel No.: Tract No.:
We are forwarding: By Messenger By Mail X Your Pickup
No. of Copies Description:
1 Plans
1 Structural calculations
1 Structural plan check comment list
Comments:
This Material Sent for:
Your Files X Per Your Request
Your Review Approval
Checking At the request of:
Other
By: John W. Thompson
Phone # 760-342-9214
47-159 Youngs Lane, Indio, CA 92201 (760) 342-9214
Bronz Young
City of La Quinta Building and Safety Department
Plan Check Corrections -
Sprint / Block Wall Engineer: Tetra Tech, Inc.
46-600 Adams St. Plan Check No.: 0111-019 (1st check)
La Quinta, California Date: 1/29/02
1. Clarify the reinforcing requirement. Plans (sheet C6) call -out #4 at 24" o/c ea. way and the
calculations (pg. 3) call -out #4 at 16" o/c ea. way.
2. Clarify whether or not the block wall requires special inspection. The cover sheet of the
calculations specifies special inspection but the calculations on page 3 state no special
inspection. Please clarify. If special inspection is required clearly specify on the plans.
3. Structural calculations shall be stamped and wetsigned by the Engineer of Record.
Please incorporate requested corrections into plan sets and reprint.
Plan Reviewer. John W. Thompson, P.E.
Phone No.: 760-342-9214 Fax No.: 760-342-6164
Sent By: Lucent Technologies;
OR-
Yp ell
562 802 5772; Jun-19-02 11:09AM; Page 2/3
SCplylyltp ., .
Lucent Technologies
Bell tabslnnovations
Global Srrvit'c PrnviduBusinrss
Attn-. Daniel Crawford, Inspector 12825 Aluxidra Blvd.
Re: Permit No.: 111019 Nor Norwalk. 1030
Noxwalk, CA 9065 L • 1036
Address: 46 0 Adams St., La Qiunta j
Job: Cell Site at Storage: USA
The following information is being provided in response to questions arising from your
inspection of the, above cell site and specifically issues with electrical inspection results
pertaining to the power cabinet.
Item) 1 Pertains to the question of whether aluminum wire is being used within the power
cabinet.
Restwnse: No Aluminum wire is used within the power cabinet. As required by
NEC Article 310-11 all wire is marked and is of type MTW or TFE copper or nickel -
coated copper. (Reference NEC Table 310-13)
Item 2 Pertains to the question of the proper grounding of a 15 amp circuit supplying the
heater within the power cabinet.
Response: The power cabinet meets the requirement of NEC Article 2.50-2 (b)
Grounding Of Electrical Equipment, i.e., "conductive.materials enclosing electrical
conductors or equipment shall be" grounded
(Note: This question arose because. a 3 conductor SO cord type cable supplies
the heater circuit with the green conductor cut at both ends and not used)
SO type cable was used to provide flekibility and for rough service.
Although 2 conductors are required for the circuit a 3 conductor cable may have been
used as a result of 2 conductor -not being available.
In conclusion NEC Article 90-7 is referenced here since the power cabinet is within the
scope of this Code Section since it is Listed (see attached label)
I hope the above information helps to resolve the issues with this site. Please call if there
are further questions or concerns. Thank you for your consideration.
Gilbert Martinez
Electrical Director
Lucent Technologies O
InslatIation West
W 562 802-5727
FAX 562 802-5772
<<:�-:i gmarti®iucent.com
1CB0/1AFT Certified Elcetrieal Inspector No, 0969566-20 California Licensed 131"trical Contractor
.. ........
1 . ...... ... .
. . . . . . . . . . . .
. . . . . . . . . .
1 V:
.... . .....
. ...... ..
. .... . . . . . . . .
. ....... ..
. . . . . . . . . . . . ...
....... ..... 1;
..... . .......
......... . .. ..
....... . ...
. ... .... . ..
.. ...... . . .
.. ... ...... .. . ... ..... ..... ..
TO:
FROM
DATE:
RE:
$,C�9NNE0
PLAN CHECK TRANS'MITTAV O, ,
City of La Quinta/Zn,,�
Community Development Department U -'t1vt.
78-495 Calle Tampico (P.O. Box 1504)
La Quinta, California 92253
760-777-7067 (Phone); 760-777-1233 (Fax)
Diane Aaker, Senior Secretary
Building and Safety Department
Greg Trousdell, Associate Pla*,-�
November 26, 2001
CUP•2001-063, Sprint Monopalm at 46-600 Adams St. (Storage USA)
Corrections requested by this Department are:
1. Provide landscape and irrigation improvements adjacent to the monopalm communication
antenna as required by Planning Commission Resolution 2001-127 (Condition #8). See the
attached conditions.
2. Specify the material to be used to cover the monopalm support pole, thereby replicating a living
palm tree.
3. Specify color of the proposed masonry block for the 6' high equipment enclosure.
4. Specify a wrought iron access gate to replace the proposed chain link fence gate.
Enc:
c: Linda Ennabe, Telecom Wireless Solutions (Fax 714-245-2515)
Betty Sawyer, Executive Secretary
PICK SprintAdams-c Gregl 1/19/ss
.f
PLANNING COMMISSION RESOLUTION 2001-127
CONDITIONS OF APPROVAL - ADOPTED
CONDITIONAL USE PERMIT 2001-063, SPRINT PCS
OCTOBER 9, 2001
CONDITIONS OF APPROVAL
1. The applicant agrees to defend, indemnify, and hold harmless the City of La
Quinta (the "City"), its agents, officers and employees from any claim, action
or proceeding to attack, set aside, void, or annul the approval of this Conditional
Use Permit. The City shall have sole discretion in selecting its defense counsel.
This indemnification shall include any award toward attorney's fees.
The City shall promptly notify the applicant of any claim, action or proceeding
and shall cooperate fully in the defense.
2. Prior to the issuance of an improvement or building permit, the applicant shall
obtain permits and/or clearances from the following public agencies, or
departments:
• Community Development Department
• Building and Safety Department
• Riverside County Fire Department
• Imperial Irrigation District (IID)
• Federal Communication Commission (FCC)
• Federal Aeronautical Association (FAA)
The applicant is responsible for any requirements of the permits or clearances
from those jurisdictions. If the requirements include approval of improvement
plans, applicant shall furnish proof of said approvals prior to obtaining City
approval of the plans.
3. Development of this site shall be in substantial conformance with Exhibits
approved and contained in the file for Conditional Use Permit 2001-063, unless
amended by the following conditions.
FEES AND DEPOSITS
4. The applicant shall pay all deposits and fees required by the City for plan
checking and construction inspection. Deposits and fee amounts shall be those
in effect when the applicant makes application for the plan checks, permits, and
inspections.
CONDCUP63 Sprint @Adams
P-Greg/9-25
Page 1 of 2
!F .
Planning Commission Resolution No. 2001-127
Conditional Use Permit 2001-063, Sprint PCS
October 9, 2001
FIRE DEPARTMENT
5. Prior to building permit issuance, final construction plans shall be submitted to
the Fire Department for review and approval.
IMPERIAL IRRIGATION DISTRICT
6. Before any cranes, forklifts, or other aerial equipment are raised, please check
for overhead wires pursuant to the provisions of California Title 8 (Electrical
Safety Orders). Non -qualified electrical workers can get no closer than 6 feet
from IID distribution lines and no closer than 10 feet from transmission lines.
People operating boom type lifting or hoisting equipment can get no closer than
10 feet from IID distribution lines and not closer than 17 feet from transmission
lines.
7. If ground excavation is required, even for seemingly benign applications such as
anchoring a tent, please contact Underground Service Alert (USA). This service
is free of charge provided USA is given at least two working days' notice (800-
227-2600).
MISCELLANEOUS
8. A minimum of two 40 foot tall palm trees shall be planted in close proximity to .
the monopalm communication tower and vines shall be espalier on the outside
of the security walls in 15-foot increments. An automatic timer irrigation
system is required.
9. Palm trees shall be maintained and replaced if they die.
10. Heavy gauge, opaque metal gates shall be installed. Chain link fencing is not
allowed.
1 1 . The applicant shall agree to allow for future joint use and/or co -location of other
telecommunication facilities at this site.
CONDCUP63 Sprint @Adams
P-Greg/9-25 Page 2 of 2
73'-0"
m
HAND HOLE -�
(3 REQUIRED @ 120'
SEPARATION)
SEE DETAIL 2/S-1
ELEVATION @ 62'-0"
E
N
0
0
0
N
1
0
z
3
n
52'-0"
3'-0"
1
14.000" ACROSS FLATS
CLAMP ON STRAIGHT ARMS
SEE SHEET S-2.
CLAMP ON DUAL CURVED ARMS
SEE SHEET S-2.
R 1 /4n 15.25' (Fy=65)
(EST WT = 0.629 KIPS)
SPLICE LENGTH
MIN = 24.30"
DESIGN = 27.00"
MAX = 32.00"
PALM FROND SHOWN FOR
ILLUSTRATIVE PURPOSES
ONLY. NOT TO SCALE.
R 1/4" X 52.00' (Fy=65)
(EST WT = 2.955 KIPS)
(1) EXIT PORT
@ 0' SEE DETAIL 1 /S-1
G
I
CV
"
z
x
w LO
to
=w
I M
DETAIL OF
JACKING NUTS
0 SPUC
BASE REACTIONS FOR FDN DESIGN
BASE R 2 1/4" X 33.625" SQUARE (WT. = 0.721 KIPS) MOMENT = 600 ft-kips
W/(8) 2.25"0 ANCHOR BOLTS IN QUADRANTS ON 33.500" B..C. WITH MIN. 6'-0" SHEAR - 10.0 kips
EMBEDMENT INTO PIER (W/NUTS & TEMPLATE PLATE @ BOT.) AXIAL 7.0 kips
TIGHTEN ANCHOR NUTS TO AISC SNUG TIGHT CONDITION. SLE DETAi� - s 4/S-1 - P
26.500" ACROSS FLATS
POLE ELEVATION
SEE SHEET S-2 FOR CAISSON
(DRILLED PIER) FOUNDATION
L 0 A D C A S E S
CASE 1 85 MPH WITH NO ICE DESIGN WIND
CASE 2 74 MPH WITH 1 /2" RADIAL ICE REDUCED WIND WITH ICE
CASE 3 50 MPH WITH NO ICE OPERATIONAL WIND
P 0
L E S P E C I F I C A T 1 0 N S
Pole Shape
Type:
18-SIDED POLYGON
Taper:
0.200000 I N FT
Shaft
Steel:
ASTM A572 GRADE 65
Base PL
Steel:
ASTM A572 GRADE 50 50 KSI
Anchor
Bolts:
2 1 4 0 x 7 -0 LONG
18J ASTM A615 GRADE 75
S H A F T S E C T 1 0 N D A T A
Shaft
Section
Section
Length
(feet)
Plate
Thickness
(in.)
Lap
S lice
tin.)
Diameter Across Flats
(inches)
@ Top
Bottom
1
2
15.25
52.00
0.2500
0.2500
27.00
14.00017.050
16.10026.5C
r
NOTE: DIMENSIONS SHOWN DO NOT INCLUDE GALVANIZING TOLERANCES
85 MPH WIND
50 MPH WIND
Elevation
Lateral
Deflection
(Inches)
Rotation
(sway)
(degrees)
Lateral
Deflection
(Inches)
Rotation
(sway)
(degrees)
TOP
4.3.2
5.632
14.9
1.949
A N T E N N A L I S T
No.
Elev.
Description
-
TOP
3 4 LIGHTNING ROD
-
TOP
PALM FRONDS
1-12
TOP
(12) COMSAT PCS A-065-19
-
TOP
DUAL CURVED ARM MOUNTS
ANTENNA FEED LINES RUN INSIDE OF POLE.
)ESIGN MEETS REQUIREMENTS OF THE FOLLOWING 1997 UBC SECTIONS:
'H. 16, DIV. III - WIND SPEED=70 MPH, EXPOSURE C, 1=1.0
H. 16, DIV. IV - SEISMIC ZONE 4, Na=1.1, Nv=1.4, SOIL PROFILE So, R=2.2
M^ I f C'I I A r r Z Z
f5'-0"0 SHAFT
CAISSON (DRIL
INTERIOR
BASE
w
Of
a
c�
U)
00
LO
B A S E P L A T E D A T A
Material: ASTM A572 GRADE 50 50 KSI
Plate Thickness in.): 2.2500
Qty. Anchor Bolts: 8
Anchor Bolt Hole Dia (in.): 2.6250
BASE PLATE DETAIL r4 N)l,
(ASTM A572 GRADE 50) S _
EXTERIOR POLE SHAFT
POLE
SHAFT 1 /4" ACK
ZI GOUGE
PLATE 1 /4"
2.2500
33.50"0
BOLT CIRCLE
26.50"0
ACROSS FLATS
20.00"0 I.D.
a
270'
N
EXIT PORT
12%24"
L
HH 6x12
.-
3"
P1M VIEW
1/4
2 CR0K,-SECTION ,r
S-
1. ALL STEEL SHALL CONFORM TO THE REQUIREMENTS OF THE "STANDARD
SPECIFICATION FOR STRUCTURAL STEEL" ASTM A572 (65 KSI YIELD POINT
MATERIAL), EXCEPT WHERE NOTED ON SHEETS S-1, S-2 OR AS NOTED
BELOW.
2. ALL STEEL PIPE SHALL CONFORM TO THE REQUIREMENTS OF ASTM
A500 GRADE C 46 KSI YIELD POINT MAT.
3. ALL STEEL SHALL BE HOT -DIPPED GALVANIZED IN ACCORDANCE WITH
ASTM A123.
4. WELDED CONNECTIONS SHALL CONFORM TO THE LATEST VERSION OF
THE AMERICAN WELDING SOCIETY A.W.S. D1.1 WELD ELECTRODES SHALL
CONFORM TO E70 ELECTRODES.
5. ALL ANTENNA FEED LINES RUN INSIDE OF POLE SHAFT.
6. THE FOLLOWING ITEMS SHOULD RECEIVE SPECIAL INSPECTION
ACCORDING TO SECTION 1701 OF THE 1998 CBC:
A) CAISSON FOUNDATION: REINFORCING CAGE SHOULD BE INSPECTED
TO ENSURE THAT THE PROPER GEOMETRY, SIZE, LENGTH, QUANTITY AND
GRADE MATERIAL ARE USED.
B) ANCHOR BOLTS: PLACEMENT SHOULD BE ORIENTED ON PROPER
BOLT CIRCLE AS SHOWN ON THE STRUCTURAL PLANS, SHOULD BE PLUMB,
SHOULD HAVE MINIMUM EMBEDMENT OF 6'-0" INTO CAISSON FOUNDATION
(12" MAX PROJECTION), NUTS SHOULD BE TIGHTENED TO A SNUG TIGHT
CONDITION PER AISC STEEL MANUAL OF STEEL CONSTRUCTION.
C) ALL A325 BOLTS AND THREADED RODS: SHOULD BE TIGHTENED TO
A SNUG TIGHT CONDITION PER THE AISC STEEL MANUAL OF STEEL
CONSTRUCTION.
D) ALL CONCRETE SHALL BE TESTED AS SPECIFIED BY ACI-318, LATEST
EDITION, TO ENSURE THE COMPRESSIVE STRENGTH IS ATTAINED AS
DESCRIBED IN THE FOUNDATION NOTES.
ERECTION NOTES:
1. THE CONTRACTOR SHALL ORIENT THE ANTENNA MOUNT AS REQUIRED
BY THE OWNER.
2. GALVANIZED SURFACES DAMAGED DURING TRANSPORTATION OR
ERECTION AND ASSEMBLY SHOULD BE TOUCHED UP USING COLD
GALVANIZING PAINT.
3. TIGHTEN ALL BOLTS TO AISC SNUG TIGHT REQUIREMENTS. THE SNUG
TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL
PLIES IN A JOINT ARE IN FIRM CONTACT, THIS MAY BE ATTAINED BY A
FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A MAN
USING AN ORDINARY SPUD WRENCH.
1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF AT
LEAST 3000 PSI AT 28 DAYS. ALL CONCRETE WORK SHALL BE IN
ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE", ACI 318, LATEST EDITION. FOUNDATION INSTALLATION SHALL
BE IN ACCORDANCE WITH ACI 336, "STANDARD SPECIFICATIONS FOR THE
CONSTRUCTION OF DRILLED PIERS", LATEST EDITION.
2. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (GRADE 60)
EXCEPT THAT CAISSON TIES MAY BE ASTM A615 (GRADE 40). ALL
REINFORCING DETAILS SHALL CONFORM TO "MANUAL OF STANDARD
PRACTICE FOR DETAILIN REINFORCED CONCRETE STRUCTURES", ACI 315,
LATEST EDiTION, UNLESS DETAILED CN i'iilS DRAWING.
3. SEE ELEVATION/S-1 FOR ANCHOR BOLT QUANTITY, SIZE, LENGTH, AND
BOLT CIRCLE.
4. TOTAL CONCRETE = 13.5 CUBIC YARDS.
5. FOUNDATION DESIGN BASED UPON GEOTECHNICAL EXPLORATION
REPORT:
PREPARED BY . . . . ATC ASSOCIATES, INC.
REPORT NO . . . . . . 40.75013.0410
DATE . . . . . . . . . . . SEPTEMBER 4, 2001
6. CONTRACTOR SHALL READ THE GEOTECHNICAL REPORT AND CONSULT
THE GEOTECHNICAL ENGINEER AS NECESSARY PRIOR TO CONSTRUCTION.
7. THE FOUNDATION WAS DESIGNED USING THE FOLLOWING SERVICE
LOADS:
MOMENT: 600 FT -KIPS
SHEAR: 10.0 KIPS
AXIAL: 7.0 KIPS
8. GEOTECHNICAL ENGINEER MUST INSPECT FOUNDATIONS PRIOR TO
PLACING REINFORCING STEEL OR FORMS. GEOTECHNICAL ENGINEER TO
PROVIDE A NOTICE OF INSPECTION FOR THE BUILDING INSPECTOR FOR
REVIEW AND RECORD PURPOSES.
9. CONTRACTOR SHALL DETERMINE THE MEANS AND METHODS TO
SUPPORT THE DRILLED PIER EXCAVATION, REFER TO THE GEOTECHNICAL
REPORT FOR RECOMENDATIONS.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTIO
DATE __ BY
:SECTION A -A