BSPN2015-001678-495 CALLE TAMPICO 4 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: TESERRA PO BOX 1280 COACHELLA, CA 92236 BSPN2015-0016 54200 AFFIRMED 767780077 CANNING RESIDENCE/EXPIRED POOL PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License_iass:G License No.: (//�' 0 Date:Contractor-" OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the.pe.rformance of the work for which this -permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's 1111 11111IIIIIIIIIIIII 73 IE VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/8/2015 Owner: ELIZABETH CANNING 27930 W RIVER TR BARRINGTON, IL 92253 Contractor: Llc. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /� Date/ �� Appli`c7a� Y: %�L{l �� e Z WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of la Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioZ.; perty for inspection -purposes. Date: 5 Signature (Applicant o�/Agent) V FINANCIAL .• 1• DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE: SPECIAL INSPECTION 101-0000-42404 1 $72.52 '$72.52 4/8/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY TESERRA CHECK R4829 128548 MFA Total Paid forCOMPLIANCE SURVEY/SPECIAL INSPECTION: $72.52 $72.52 Description: CANNING RESIDENCE/EXPIRED POOL PERMIT Type: SPECIAL INSPECTION Subtype: Status: ISSUED Applied: 4/8/2015 MFA Approved: 4/8/2015 MFA Parcel No: 767780077 Site Address: 54200 AFFIRMED LA QUINTA,CA 92253 Subdivision: TR 32879 Block: Lot: 300 Issued: 4/8/2015 MFA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $0.00 Occupancy Type: Construction Type: Expired: 10/5/2015 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: SPECIAL INSPECTION REQUIRED TO COMPLETE FINAL ON PERMIT 091007 _.._1 Applied to Approved Approved to Issued CONDITIONS Printed: Wednesday, April 08, 2015 4:55:58 PM 1 of 2 g SYS7Eti1S PARENT PR0j L : is BOND INFORMATION Printed: Wednesday, April 08, 2015 4:55:58 PM 2 of 2 sysrrnes 0 GEOTECHNICAL INVESTIGATION PROPOSED GRIFFIN RANCH RESIDENTIAL DEVELOPMENT SEC AVENUE 54 AND MADISON STREET LA QUINTA, CALIFORNIA -Prepared By- Sladden Engineering 39-725 Garand Lane, Suite G Palm Desert, California 92211 (760) 772-3893 IIIIII III I III VIII IIII 74 IE Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895 August 17, 2004 Transwest Housing, Inc. 47-120 Dune Palms Road, Suite C La Quinta, California 92253 Attention: Mr. Rod Grinberg Project: Proposed Griffin Ranch Residential Development SEC Avenue 54 and Madison Street La Quinta, California Subject: Geotechnical Investigation Project No. 544-4402 04-08-571 Presented herewith is the report of our Geotechnical Investigation conducted for the construction of the proposed approximately 195 -acre residential development to be located on the southeast corner of Avenue 54 and Madison Street in the City of La Quinta, California. The investigation was performed in order to provide recommendations for site preparation and to assist in foundation design for the proposed residential structures and the related site improvements. This report presents the results of our field investigation and laboratory testing along with conclusions and recommendations for foundation design and site preparation. This report completes our original scope of services as outlined within our proposal dated July 8, 2004. We appreciate the opportunity to provide service to you on this project. If you have any questions regarding this report, please contact the undersigned Respectfully submitted, SLADDEN ENGINEERING BR -TTL. Uj ANDERSON Brett L. Anderso No. . C45389 � 8/3phq Principal Engineer Ewa. SER/pc Copies: 6/Transwest Housing August 17, 2004 4- Project No. 544-4402 04-08-571 Based upon the depth to groundwater and the generally firm condition of the deeper sand layers, it is our opinion that the potential for liquefaction affecting the site is minimal. The remedial grading recommended for building areas will result in the construction of a uniform compacted soil mat beneath all footings. In our opinion, liquefaction related mitigation measures in addition to the site grading and foundation design recommendations included in this report should not be necessary. The site is located in one of the more seismically active areas in California. Design professionals should be aware of the site setting and the potential for earthquake activity during the anticipated Iife of the structure should be acknowledged. The accelerations that may be experienced on the site (as previously discussed) should be considered in design. The seismic provisions included in the Uniform Building Code for Seismic Zone 4 should be considered the minimum design criteria. Pertinent 1997 UBC Seismic Design Criteria is summarized in Appendix C. Caving did occur within our borings and the potential for caving should be expected within deeper excavations. All excavations should be constructed in accordance with the normal CalOSHA excavation criteria. On the basis of our observations of the materials encountered, we anticipate that the near surface silty sands will be classified by CaIOSHA as Type C. Soil conditions should be verified in the field by a "Competent person" employed by the Contractor. The near surface soils encountered during our investigation were found to be non -expansive. Laboratory testing indicated an Expansion Index of 0 for the surface silty sands and sandy silts that corresponds with the "very low" expansion category in accordance with UBC Table 18 -I -B. The following recommendations present more detailed design criteria which have been developed on the basis of our field and laboratory investigation. The recommendations are based upon non -expansive soils criteria. Foundation Design: The results of our investigation indicate that either conventional shallow continuous footings or isolated pad footings that are supported upon properly compacted soils, may be expected to provide adequate support for the proposed structure foundations. Building pad grading should be performed as described in the Site Grading Section of this report to provide for uniform and firm bearing conditions for the structure foundations. Footings should extend at least 12 inches beneath lowest adjacent grade. Isolated square or rectangular footings should be at least two feet square and continuous footings should be at least 12 inches wide. Continuous footings may be designed using an allowable bearing value of 1500 pounds per square foot (psf) and isolated pad footings may be designed using an allowable bearing pressure of 1800 psf. The allowable bearing pressures are applicable to dead and frequently applied live loads. The allowable bearing pressures may be increased by 1/3 to resist wind and seismic loading. Care should be taken to see that bearing or subgrade soils are not allowed to become saturated from the ponding of rainwater or irrigation. Drainage from the building area should be rapid and complete. Sladden Engineering i August 17, 2004 -5- Project No. 544-4402 04-08-571 The recommendations provided in the preceding paragraph are based on the assumption that all footings will be supported upon properly compacted engineered fill soils. All grading should be performed under the testing and inspection of the Soils Engineer or his representative. Prior to the placement of concrete, we recommend that the footing excavations be inspected in order to verify that they extend into compacted soil and are free of loose and disturbed materials. Settlements: Settlements resulting from the anticipated foundation loads should be minimal provided that the recommendations included in this report are considered in foundation design and construction. The estimated ultimate settlements are calculated to be approximately one inch when using the recommended bearing values. As a practical matter, differential settlements between footings can be assumed as one-half of the total settlement. Lateral Design: Resistance to lateral loads can be provided by a combination of friction acting at the base of the slabs or foundations and passive earth pressure along the sides of the foundations. A coefficient of friction of 0.40 between soil and concrete may be used with consideration to dead load forces only. A passive earth pressure of 250 pounds per square foot, per foot of depth, may be used for the sides of footings that are poured against properly compacted native or approved non -expansive import soils. Passive earth pressure should be ignored within the upper 1 foot except where confined (such as beneath a floor slab). Retaining Walls: Retaining walls may be necessary to accomplish the proposed construction. Lateral pressures for use in retaining wall design can be estimated using an equivalent fluid weight of 35 pcf for level free -draining native backfill conditions. For walls that are to be restrained at the top, the equivalent fluid weight should be increased to 55 pcf for level free - draining native backfill conditions. Backdrains should be provided for the full height of the walls. Expansive Soils: Due to the prominence of "very low" expansion category soils near the surface, the expansion potential of the foundation bearing soils should not be a controlling factor in foundation or floor slab design. Expansion potential should be reevaluated subsequent to grading. Concrete Slabs -on -Grade: All surfaces to receive concrete slabs -on -grade should be underlain by a minimum compacted non -expansive fill thickness of 24 inches, placed as described in the Site Grading Section of this report. Where slabs are to receive moisture sensitive floor coverings or where dampness of the floor slab is not desired, we recommend the use of an appropriate vapor barrier or an adequate capillary break. Vapor barriers should be protected by sand in order to .reduce the possibility of puncture and to aid in obtaining uniform concrete curing. Reinforcement of slabs -on -grade in order to resist expansive soil pressures should not be necessary. However, reinforcement will have a beneficial effect in containing cracking due to concrete shrinkage. Temperature and shrinkage related cracking should be anticipated in all concrete slabs -on -grade. Slab reinforcement and the spacing of control joints should be determined by the Structural Engineer. Sladden Engineering GEOTECHNICAL INVESTIGATION PROPOSED GRIFFIN RANCH DEVELOPMENT SEC AVENUE 54 & MADISON STREET LA QUINTA, CALIFORNIA August 17, 2004 TABLE OF CONTENTS INTRODUCTION .................... SCOPE OF WO ............................... ..................................................... .................................................. PROJECT DESCRIPTI ...................................................................... GEOLOGY AND SEISMICITY .............................. ............................. ............................................ .............. SUBSURFACE CONDITIONS................. ........................ .......................................... ....................... LIQUEFACTION ..... .............................. CONCLUSIONSAND RECOMMENDATIONS ...................i..................................................•.... Foundation Desi ................................. ""' ...... Settlements ................................................ Lateral Design.................................................................................................................................. Retain' t ......................................................... ing Walls ............... ................................... ..... ; Expansive Soils ..................................... Concrete Slabs-on-Grade................................................................................................................. ...................................... Soluble Sulfates ................ ................................. .......... . ................................................ Tentative Pavement Design . ... .........'.... '................... ..... E ....................... Shrinkage and Subsidence....................................................................................... E ........................................ General Site Gradin .......... 6 1. Site Clearing.....' learin ........................................... 6 2. Preparation of Building and Foundation ArAreas.......................................... 6 3. Placement of Com ...............................................— 7 pacted Fill ................. 4. Preparation of Slab and d Pavement Areas........................................................................... Testing and Inspection ............. ......................................... 7 GENERAL5. ................................... .................................................... 7 REFERENCES ............ APPENDIX A - Site Plan and Boring Logs Field Exploration APPENDIX B - Laboratory Testing Laboratory Test Results APPENDIX C - 1997 UBC Seismic Design Criteria 1 August 17, 2004 INTRODUCTION Project No. 544-4402 04-08-571 This report presents the results of our Geotechnical Investigation performed in order to provide recommendations for site preparation and to assist in the design and construction of the foundations for the single-family residences proposed for the Griffin Ranch development. The project site is located on the southeast corner of Avenue 54 and Madison Street in the City of La Quinta, California. The preliminary plans indicate that the proposed project will include single-family residences along with various associated site improvements. The associated site improvements are expected to include paved roadways, concrete driveways and patios, underground utilities, and landscape areas. SCOPE OF WORK The purpose of our investigation was to determine certain engineering characteristics of the near surface soils on the site in order to develop recommendations for foundation design and site preparation. Our investigation included field exploration, laboratory testing, literature review, engineering analysis and the preparation of this report. Evaluation of hazardous materials or other environmental concerns was not within the scope of services provided. Our investigation was performed in accordance with contemporary geotechnical engineering principles and practice. We make no other warranty, either express or implied. PROJECT DESCRIPTION The approximately 195 -acre project site is located on the southeast comer of Avenue 54 and Madison Street in the City of La Quinta, California. It is our understanding that the project will consist of single- family residences along with various associated site improvements. It is our understanding that the proposed residences will be of relatively lightweight wood -frame construction and will be supported by conventional shallow spread footings and concrete slabs on grade. The associated improvements will include paved roadways, concrete walkways, patios, driveways, landscape areas and various underground utilities. The majority of the subject site is presently vacant and the ground surface is covered with scattered desert brush, short grass and weeds. Large tamarisk trees exist along the majority of the property lines. The majority of the property has apparently been previously used for agricultural purposes. The property has been leveled throughout and is near the elevation of the adjacent properties and roadways. The Griffin estate located within the central portion of the property is not a part of the proposed project. The eastern portion of the Griffin estate including a horse racing track and fields are a part of, the proposed development. The PGA West development forms the southern site boundary and exists west of the site across Madison Street. There is a residential subdivision along the southeastern edge of the site. The properties along the northeast property boundary and north of the site across Avenue 54 remain vacant. Sladden Engineering i August 17, 2004 -2- Project No. 544-4402 04-08-571 Based upon our previous experience with lightweight residential structures, we expect that isolated column loads will be less than 30 kips and wall Ioading will be less than to 2.0 kips per linear foot. Grading is expected to include minor cuts and fills to match the nearby elevations and to construct slightly elevated building pads to accommodate site drainage. This does not include removal and recompaction of the bearing soils within the building areas. If the anticipated foundation loading or site grading varies substantially from that assumed the recommendations included in this report should be reevaluated. GEOLOGY AND SEISMICITY The project site is located within the central Coachella Valley that is part of the broader Salton Trough geomorphic province. The Salton Trough is a northwest trending depression that extends from the Gulf of California to the Banning Pass. Structurally the Salton Trough is dominated by several northwest trending faults, most notable of which is the San Andreas system. A relatively thick sequence of sedimentary rocks have been deposited in the Coachella Valley portion of the Salton Trough from Miocene to present times. These sediments are predominately terrestrial in nature with some lacustrian and minor marine deposits. The mountains surrounding the Coachella Valley are composed primarily of Precambrian metamorphic and Mesozoic granitic rock. The Coachella Valley is situated in one of the more seismically active areas of California. The San Andreas fault zone is considered capable of generating a maximum credible earthquake of magnitude 8.0 and due to its proximity to the project site the distance of approximately 9.9 kilometers should be considered in design fault for the project. Seismic activity along the nearby faults continues to affect the area and the Coachella Valley is considered one of the more seismically active regions in California. A computer program and pertinent geologic literature were utilized to compile data related to earthquake fault zones in the region and previous seismic activity that may have affected the site. E.Q. Fault Version 3.00 (Blake) provides a compilation of data related to earthquake faults in the region. The program searches available databases and provides both distances to causitive faults and the corresponding accelerations that may be experienced on the site due to earthquake activity along these faults. The attenuation relationship utilized for this project was based upon Joyner & Boore (1987) attenuation curves. The information generated was utilized in our liquefaction evaluation The site is not located in any Earthquake Fault zones as designated by the State but is mapped in the County's Liquefaction and Ground Shaking Hazard Zone V. Several significant seismic events have occurred within the Coachella Valley during the past 50 years. The events include Desert Hot Springs - 1948 (6.5 Magnitude), Palm Springs - 1986 (5.9 Magnitude), Desert Hot Springs - 1992 (6.1 Magnitude), Landers -1992 (7.5 Magnitude) and Big Bear -1992 (6.6 Magnitude). Sladden Engineering . 1 August 17, 2004 -3- Project No. 544-4402 04-08-571 SUBSURFACE CONDITIONS The soils underlying the site consist primarily of fine-grained silty, sands with scattered generally thin sandy clayey silt layers. As is typical for the area, the silty sand and sandy silt Iayers are inconsistently interbedded and vary in thickness. Silty sands were the most prominent soils within our exploratory borings but several prominent sandy silt and clayey silt layers were also encountered. The silty sands encountered near the existing ground surface appeared somewhat loose but the deeper silty sand and sandy silt layers appeared relatively firm. Sampler penetration resistance (as measured by field blowcounts) indicate that density generally increases with depth. The site soils were dry on the surface -but moist below a depth of approximately 5 feet. Laboratory testing indicates that the surface soils within the upper 5 feet consist primarily of silty sands. Expansion testing indicates that the surface silty sands are generally non -expansive and are classified as $,very low" expansion category soils in accordance with Table 18 -I -B of the 1997 Uniform Building Code. Groundwater was not encountered within our borings that extended to a depth of approximately 50 feet below the existing ground surface. Groundwater should not be a factor in design or construction. LIQUEFACTION Liquefaction occurs with sudden loss of soil strength due to rapid increases in pore pressures within cohesionless soils as a result of repeated cyclic loading during seismic events. Several conditions must be present for liquefaction to occur including; the presence of relatively shallow groundwater, generally loose soils conditions, the susceptibility of soils to liquefaction based upon grain -size characteristics and the generation of significant and repeated seismically induced ground accelerations. Liquefaction affects primarily loose, uniform grained cohesionless sands with low relative densities. In the case of this project site, several of the factors required for liquefaction to occur are absent. As previously indicated, groundwater was not encountered within our borings that extended to a depth of approximately 50 feet below the existing ground surface on the site. Due to the depth to groundwater, the potential for liquefaction affecting the site is considered. negligible, . _... . CONCLUSIONS AND RECOMMENDATIONS Based upon our field investigation and laboratory testing, it is our opinion that the proposed residential development is feasible from a soil mechanic's standpoint provided that the recommendations included in this report are considered in building foundation design and site preparation. Due to the somewhat loose condition of the surface soils, remedial grading is recommended for the building areas. We recommend that remedial grading within the proposed building areas include the overexcavation and recompaction of the primary foundation bearing soils. Specific recommendations for site preparation are presented in the Site Grading section of this report. Sladden Engineering I 0 August 17, 2004 -6- Project No. 544-4402 04-08-571 Soluble Sulfates: The soluble sulfate concentrations of the surface soils have not yet been determined but native soils in the area have been known to be potentially corrosive with respect to concrete. The use of Type V cement and specialized sulfate resistant concrete mix designs may be necessary for concrete in contact with the native soils. Tentative Pavement Design: All paving should be underlain by a minimum compacted fill thickness of 12 inches (excluding aggregate base). This may be performed as described in the Site Grading Section of this report. R -Value testing was not conducted during our investigation but based upon the sandy nature of the surface soils, an R -Value of approximately 50 appears appropriate for preliminary pavement design. The following preliminary onsite pavement section is based upon a design R -Value of 50. Onsite Pavement (Traffic Index = 5.0) Use 3.0 inches of asphalt on 4.5 inches of Class 2 base material Aggregate base should conform to the requirements for Class 2 Aggregate base in Section 26 of CalTrans Standard Specifications, January 1992. Asphaltic concrete should conform to Section 39 .of the CalTrans Standard Specifications. The recommended sections should be provided with a uniformly compacted subgrade and precise control of thickness and elevations during placement. Pavement and slab designs are tentative and should be confirmed at the completion of site grading when the subgrade soils are in-place. This will include sampling and testing of the actual subgrade soils and an analysis based upon the specific traffic information Shrinkage and Subsidence: Volumetric shrinkage of the material that is excavated and replaced as controlled compacted fill should be anticipated. We estimate that this shrinkage could vary from 20 to 25 percent. Subsidence of the surfaces that are scarified and compacted should be between 0.1 and 0.3 tenths of a foot. This will vary depending upon the type of equipment used, the moisture content of the soil at the time of grading and the actual degree of compaction attained. These values for shrinkage and subsidence are exclusive of losses that will occur due to the stripping of the organic material from the site and the removal of oversize material. General Site Grading: All grading should be performed in accordance with the grading ordinance of the City of La Quinta, California. The following recommendations have been developed on the basis of our field and laboratory testing and are intended to provide a uniform compacted mat of soil beneath the building slabs and foundations. 1. Site Clearing: Proper site clearing will be very important. Any existing vegetation, slabs, foundations, abandoned underground utilities or irrigation lines should be removed from the proposed building areas and the resulting excavations should be properly backfilled. Soils that are disturbed during site clearing should be removed and replaced as controlled compacted fill under the direction of the Soils Engineer. Sladden Engineering August 17, 2004 -7- Project No. 5444402 04-08-571 2. Preparation of Building and Foundation Areas: In order to provide adequate and uniform bearing conditions, we recommend overexcavation throughout the proposed residential building areas. The building areas should be overexcavated to a depth of at least 3 feet below existing grade or 2 feet below the bottom of the footings, whichever is deeper. The exposed soils should then be scarified to a depth of 1 -foot, moisture conditioned and recompacted to at least 90 percent relative compaction. The excavated material may then be replaced as engineered fill material as recommended below. 3. Placement of Compacted Fill: Within the building pad areas, fill materials should be spread in thin lifts, and compacted at near optimum moisture content to a minimum of 90 percent relative compaction. Imported fill material shall have an Expansion Index not exceeding 20. The contractor shall notify the Soils Engineer at least 48 hours in advance of importing soils in order to provide sufficient time for the evaluation of proposed import materials. The contractor shall be responsible for delivering material to the site that complies with the project specifications. Approval by the Soils Engineer will be based upon material delivered to the site and not the preliminary evaluation of import sources. Our observations of the materials encountered during our investigation indicate that compaction within the native soils will be most readily obtained by means of heavy rubber tired equipment and/or sheepsfoot compactors. A uniform and near optimum moisture content should be maintained during fill placement and compaction. 4. Preparation of Slab and Paving Areas: All surfaces to receive asphalt concrete paving or exterior concrete slabs -on -grade, should be underlain by a minimum compacted fill thickness of 12 inches. This may be accomplished by a combination of overexcavation, scarification and recompaction of the surface, and replacement of the excavated material as controlled compacted fill. Compaction of the slab and pavement areas should be to a minimum of 90 percent relative compaction. 5. Testing and Inspection: During grading tests and observations should be performed by the Soils Engineer or his representative in order to verify that the grading is being performed in accordance with the project specifications. Field density testing shall be performed in accordance with applicable ASTM test standards. The minimum acceptable degree of compaction shall be 90 percent of the maximum dry density as obtained by the ASTM D1557-91 test method. Where testing indicates insufficient density, additional compactive effort shall be applied until retesting indicates satisfactory compaction. Sladden Engineering August 17, 2004 -8- Project No. 544-4402 04-08-571 GENERAL The findings and recommendations presented in this report are based upon an interpolation of the soil conditions between boring locations and extrapolation of these conditions throughout the proposed building area. Should conditions encountered during grading appear different than those indicated in this report, this office should be notified. This report is considered to be applicable for use by Trans West Development, Inc. for the specific site and project described herein. The use of this report by other parties or for other projects is not authorized. The recommendations of this report are contingent upon monitoring of the grading operations by a representative of Sladden Engineering. All recommendations are considered to be tentative pending our review of the grading operations and additional testing, if indicated, If others are employed to perform any soil testing, this office should be notified prior to such testing in order to coordinate any required site visits by our representative and to assure indemnification of Sladden Engineering. We recommend that a pre -job conference be held on the site prior to the initiation of site grading. The purpose of this meeting will be to assure a complete understanding of the recommendations presented in this report as they apply to the actual grading performed. Sladden Engineering August 17, 2004 -9- Project No. 5444402 04-08-571 REFERENCES ASCE Journal of Geotechnical Engineering Division, April 1974. Boore, Joyner and Puma] (1994) Estimation of Response Spectra and Peak Accelerations from North American Earthquakes, U. S. Geological Survey, Open File Reports 94-127 and 93-509. Finn, W. E. Liam, (1996) Evaluation of Liquefaction: Potential for Different Earthquake Magnitudes and Site Conditions, National Center for Earthquake Engineering Research Committee. Joyner and Boore, (1988) Measurements, Characterization and Prediction of Strong Ground Motion, ASCE Journal of Geotechnical Engineering, Special Publication No. 20. Lee & Albaisa (1974) "Earthquake Induced Settlements in Saturated Sands". ' Seed and Idriss (1982) Ground Motions and Soil Liquefaction During Earthquakes, Earthquake Engineering Research Institute Monograph. Seed, Tokimatsu, Harder and Chung, (1985), Influence of SPT Procedures in Soil Liquefaction Resistance Evaluations, ASCE Journal of Geotechnical Engineering, Volume 111, No. 12, December. Rogers, Thomas I -I., Geologic Map of California, Santa Ana Map Sheet. Riverside County,1984, Seismic Safehj Element of the Riverside County General Plan Sladden Engineering S201 supog UeId alis V XIaN3ddV APPENDIX A FIELD EXPLORATION For our field investigation, 16 exploratory borings were excavated on July 16 and August 4, 2004, using a truck mounted hollow stem auger rig (Mobile B-61) in the approximate locations indicated on the site plan included in this appendix. Continuous log of the materials encountered were prepared on the site by a representative of Sladden Engineering. Boring logs are included in this appendix wn _ Representative undisturbed samples were.. obtained within our ltg. by driving; -a-.' illed steel penetration sampler (California split spoon sampler) or a Standard Penetration Test (S1'T'sampler with a 140 pound hammer dropping approximately 30 inches (ASTM D1586). The number of blows required to drive the samplers 18 inches was recorded (generally in 6 inch increments). Blowcounts are indicated on the boring log. The California samplers are 3.0 inches in diameter, carrying brass sample rings having inner diameters of 2.5 inches. The standard penetration samplers are 2.0 inches in diameter with an inner diameter of 1.5 inches. Undisturbed samples were removed from the sampler and placed in moisture sealed containers in order to preserve the natural soil moisture content. Bulk samples were obtained from the excavation spoils and samples were then transported to our laboratory for further observations and testing. Griffin Ranch SEC Avenue 54 and Madison Street —Boring No. 1 Job Number: 0 a a 110 W � 3 y tiaenrinfin.. O .� O I/5/8 Dry Silty Fine Sand SM 8/l 1 Dry Fine to Medium Sand with Traces of Silt SM 6/7 Dry Silty Fine Sand SM 5/7 Dry Silty Fine Sand SM 5/6 Clayey Silt 1 W sit 1 1 I ` If 1 67 y IEF- Grey in color 1,,:o 1 69 Grey in color 15 79 Grey in color 4 69 Grey in color i Note: The stratification lines ,. a represent the approximate between the soil 4 k types; the transition may be Griffin Ranch SEC Avenue 54 and Madison Street —Boring No. 1 Job Number: 0 a a 110 W � 3 y tiaenrinfin.. O .� O I/5/8 Dry Silty Fine Sand SM 8/l 1 Dry Fine to Medium Sand with Traces of Silt SM 6/7 Dry Silty Fine Sand SM 5/7 Dry Silty Fine Sand SM 5/6 Clayey Silt Mi. 35 40 - 45 50 3/4/7 5/6/9 • 3/5/13 Clayey Silt Slightly moist Clayey Silt with Traces of Fine Sand Slightly moist Clayey Silt with Traces of Fine Sand with a Layer of Silty Fine Sand -4" ML ML ML — Grey in color 1 7 6/9/17 9/15/20 1 Slightly Moist Silty Fine Sand Slightly Moistit Fine Sand SM SM — Grey in color 1 1 I Sladden Engineering Native Soils 5 — Grey in color 1 7 Grey in color 1 — Grey in color 1 1 I Grey in color Firmly Packed 1 67 Grey in color 1 69 Grey in color 15 79 Grey in color 4 69 Grey in color Note: The stratification lines represent the approximate between the soil 4 -~boundaries types; the transition may be gradual. Total Depth - -50' 3 I4 Groundwater not encountered Bedrock not encountered ' Griffin Ranch SEC Avenue 54 and Madison Street Date: 7/16/2004 Boring No. 2 Job Number: 544-4402 V V3 0 U - C m Description 0a 0. q c o a N oRemarks 0 Native Soils 5 6/10/13 Firm Clayey Silt ML 7 -- Grey in color 10 3/4/6 Clayey Silt with Silty Fine Sand Layer –6" ML 6 77 Grey in color 15 5/6/6 Dry Sandy Silt ML 3 71 Grey in color 20 Grey in color 4/6/8 Dry Silty Fine Sand SM 2 -- 25 3/6/11 Silty Medium to Coarse Sand SM 19 -- Grey in color 30 4/6/7 Silty Fine Sand SM 19 -- Grey in color 35 4/5/6 Silty Fine Sand with From Sandy Silt Layer --5" SM 5 — Grey in color ' -represent Note: The stratification lines the approximate 40 315/7 Silty Fine Sand SM 3 13 boundaries between the soil types; the transition may be gradual. 45 4/5/4 Moist Silty Fine to Medium Sand with a very Moist SM 19 --- Grey in color - Sandy and Clayey Silt Layer –6" - Total Depth = –5V - Groundwater encountered 50' 50 3/6/9 IWet Sandy and Clayey Silt with Slity Fine Sad SM 24 26 Bedrock not encountered Sladden Engineering Griffin Ranch SEC Avenue 54 nnrl Mnrlicnn Ctrnot Date: 7/16/2004 Boring No. 3 Job Number: 544-4402 y O V 0 r a O oRemarks oy Surrounding Area is Flood - Irrigated 5 3/3/5 Moist Silty Fine to Medium Sand SM 113 4 17 Grey in color 10 4/5/6 Moist Silty Fine Sand SM 6 21 Grey in color 15 Grey in color 1/1/1 Wet Clayey Silt Layer -10" ML 34 84 20 2/2/2 Wet Clayey Silt Layer –10" with Silty Fine Sand ML 27 71 Grey in color 25 Grey in color 3/3/6 Moist Silty Fine to Medium Sand with a Clayey Silt SM 19 — - Layer -6" 30 _ Grey in color '':« g«>:> 3/2/2005 Moist Silty Clay Layer -16" CL 35 89 35 Grey in color 5/7/9 Moist Fine to Medium Sand with Traces of Silt SP 6 10 Note: The stratification lines - represent the approximate 40 5/8/11 Moist Fine to Medium Sand with Traces of Silt SP 4 7 boundaries between the soil - types; the transition may be gradual. 45 6/10/16 Moist Fine to Medium Sand with Traces of Silt SP 5 8 Grey in color Total Depth = –50' Bedrock not encountered 50 9/9/17 Moist Fine to Medium Sand with Traces of Silt SP 9 16 lGroundwater not encountered Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 7/16/2004 Boring No. 4 Job Number: 4.o a� OWU o3w. 1�P.Crrinhinn n C •O 5 10 I5 20 25 30 35 40 45 50 ve 4/719 IDry Silty Fine Sand SM 11 1 2 1 20 JIGrey in color 3/7/10 (Damp Silty Fine Sand SM 11 1 6 1 25 Grey in color — I -- 110rey in color 2/3/4 IMoist Sandy and Clayey Silt I ML I _ _— II Grey in color Depth = —20' ck not encountered dwater not encountered Recovered Sample Unrecovered Sample Standard Penetration Sample The stratification lines represent the approximate cries between the soil types; the transition may be i i Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No. 5 Job Number: 544-4402 - a 1601 3 a o U o a4 Description 0 Remarks 0 Native Soils 5 3/12123 Dry Silty Clay CL 2 93 Greyish Brown in color 10 Grey in color 9/11/24 Dry Fine to Medium Sand with Traces of Silt SP 1 7 15 Grey in color 14/15/27 Dry Clayey Silt ML 4 89 20 . G Grey in color 17/50-6" Dry Silty Fine an 1 Total Depth =--20' Bedrock not encountered 25 Groundwater of encountered 30 - Recovered Sample I - - Unrecovered Sample I - Standard Penetration Sample 35 40 Note: The stratification lines represent the approximate - boundaries between the soil types, the transition may be - gradual. 45 50 Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Sheet Date: 8/4/2004 Boring No. 6 Job Number: 544-4402 a. Nt CrI y y y Ca U g pq Description r° 42 �t Remarks 0 _ I Native Soils 5 19/30/32 Dry Silty Fine Sand SM 1 — Grey in color _ 10 l Greyish brown in color 10/23/20 Dry Fine Sand with Traces of Silt SP 1 — IS IlGrey in color 0 lU/15 DrySilty Fine Sandwith a Clayey Sit Layer -- ' SM 1 62 -Total Depth —IS' " Bedrock not encounered Groundwater not encountered 20 25 30Recovered Sample - Unrecovered Sample - Standard Penetration Sample 35 40 Note: The stratification lines represent the approximate - boundaries between the soil types; the transition may be - gradual. 45 50 Sladden Engineering ' Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No. T Job Number: 544-4402 U C CO D CI o En I U G M Description rn a Remarks 0 i t ' Native Soils 5/10/15 Dry Silty Fine Sand SM 0 -- Grey in color - A i 10 0 b/10/19 Dry Silty Fine Sand SM 2 22 Grey in color _ W i 15 i Grey in color 9/26/24 Dry Clayey Silt ML 6 81 20 Grey in color 8 11 15Si ty an "Total Depth = --20' " Bedrock not encountered 25 _ Recovered Sample I Groundwater not encountered - _ Unrecovered Sample I - Standard Penetration Sample 30 35 Note: The stratification lines represent the approximate - boundaries between the soil types; the transition may be ` gradual, 40 45 50 Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No. 8 Job Number: 544-4402 IU 3 o�v� U o G4 Descri tion rn ] o emarks _ V i Native Soils 5 10/33/50-6" Dry Silty Fine Sand SM 1 Grey in color 10 16/22/30 Dry Silty Fine Sand SM 1 11 Grey in color 15 14/22/26 Dry Silty Fine Sand with Traces of Clay SM 4 35 Greyish Brown in color 20 Total Depth —IS' Bedrock not encountered _ Groundwater not encountered - Recovered Sample 25 - Unrecovered Sample - Standard Penetration Sample 30 Note: The stratification lines represent the approximate 35 boundaries between the soil types; the transition may be - gradual. 40 45 50 Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No. 9 Job Number: 5444402 qL) 0MD�' Description M CL •s 0 a a Remarks 0 Native Soils 5 8/14/30 Slightly Moist Silty Clay and Silty Fine Sand CL 10 92 Greyish Brown in color 10 Brown in color 22/22/50-6" Slightly Moist Fine to Medium Sand with Traces of Silt SP 2 11 l5 Greyish Brown in color Total Depth =-15' 15/20/22 ine Sandy Sit withTraces o la ML - P Recovered Sample - I Bedrock not encountered 20 Unrecovered Sample Groundwater not encountered - Standard Penetration Sample 25 30 - Note: The stratification lines represent the approximate - boundaries between the soil types; the transition may be - gradual. 35 40 45 50 Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No. 10 Job Number: 544-4402 R e N � O y a N � O O JP4 p IM U Description 0 Remarks 0 Native Soils 5 9/11/I2 Dry Fine Sand with Traces of Silt SP 2 -- Grey in color 10 _: 11/7/13 Dry Fine Sand with Traces of Silt SP 1 17 Grey in color 15 7/10/16 Dry Fine Sand with Traces of Silt SP 1 ] 5 rey in color 20 . Grey in color 10/14 1 Dry Clayey Silt 3 -r-68-- - Recovered Sample Total Depth = —29 25 ( Bedrock not encountered - >< Unrecovered Sample Groundwater not encountered _ - I Standard Penetration Sample 30 35 - Note: The stratification lines represent the approximate - boundaries between the soil types; the transition may be - gradual. 40 45 50 Sladden Engineering • Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No. 11 Job Number: 544-4402 0 N 0 a p rn O U 0 Description y 0 Remarks 0 Native Soils 5 5/8/13 Slightly Moist Fine to Medium Sand with Trace Silt SP 1 9 Grey in color 10 `•. 4/6/9 Slightly Moist Fine to Medium Sand with Trace Silt SP 4 -- Greyish Brown in color - and a Sandy Silt Layer --6" 15 ' 5/9/12 Moist Fine Sand with Traces of Silt SP 2 14 Grey in color - Recovered Sample Total Depth —i 5' _ I Bedrock not encountered 20 Unrecovered Sample I Groundwater not encountered _ - Standard Penetration Sample 25 30 35 - Note: The stratification lines represent the approximate _ boundaries between the soil types; the transition may be - gradual. 40 45 50 11 Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No.12 Job Number: 544-4402 o a c A cn U Description rn Remarks 0 Native Soils 5 4/6/8 Moist Silty Fine Sand SM 3 — Grey in color 10 Dark Grey in color 4/3/4 Wet Silty Clay Layer --5" and Sandy Silt ML 1 85 15 "E��Wel ark Grin color Silty Clay CL L 1 93 - Recovered Sample Total Depth —15' - I Bedrock not encountered 20 Unrecovered Sample Groundwater not encountered - Standard Penetration Sample 25 30 _ Note: The stratification lines represent the approximate _ boundaries between the soil types; the transition may be - gradual. 35 40 45 50 Sladden Engineering Griffin Ranch a SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No.13 Job Number: 5444402 0 4 rn U° 0 pq Description c 0 z e Remarks 0 Native Soils 5 5/5/6 Moist Silty Fine Sand SM 6 26 Grey in color - C 10 Dark Grey in color 5/5/10 Wet Clayey Silt ML 30 87 15 ark in color 2/3/6 Wet Silty Fine Sand with Traces of Clay SM 13 — - Recovered Sample Total Depth —15'. _ I Bedrock not encountered 20 Unrecovered Sample Groundwater not encountered - Standard Penetration Sample 25 30 - Note: The stratification lines represent the approximate - boundaries between the soil types; the transition may be 35 gradual. 40 45 [501 Sladden Engineering . Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No.14 Job Number: 544-4402 0 0 A ri U M Description �, Remarks 0 ! 'Native Soils 5 6/10/12 Dry Silty Fine Sand with a Clayey Silt Layer -6" SM 13 -- Light Greyish Brown in color 10 7/16/16 Dry Silty Fine Sand SM 1 --- Grey in color 15,11• 9/1620 Slightly Moist Silty Fine Sand SM 1 — Grey in color - Recovered Sample Total Depth —151 _ I Bedrock not encountered 20 Unrecovered Sample Groundwater not encountered - Standard Penetration Sample 25 30 - Note: The stratification lines represent the approximate _ boundaries between the soil types; the transition may be 35 gradual. 40 45 so Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No.15 Job Number: 5444402 0 Cl o 'o 0 Q v, U pq Description rn° p o Remarks 0 Native Soils 5 515!7 Slightly Moist Silty Fine Sand SM 3 13 Grey in color 10 4/5/8 Silty Fine Sand with Traces of Clay SM 15 36 Light Greyish Brown in color 15' 5/6/13 1 Silty Fine Sand with a Clayey Silt Layer -8" SM 4 --- Grey in color - Recovered Sample Total Depth x-15' - I Bedrock not encountered 20 Unrecovered Sample Groundwater not encountered _ - I Standard Penetration Sample 25 30 - Note: The stratification lines represent the approximate _ boundaries between the soil types; the transition may be _ gradual. 35 40 45 50 Sladden Engineering Griffin Ranch SEC Avenue 54 and Madison Street Date: 8/4/2004 Boring No.16 Job Number: 544-4402 a 0 G 3 E rn 2 U o r q Description _ rn° 2 a Remarks 0 i. I' Native Soils I 5 4/6/7 Silty Fine Sand with a Clayey Silt Layer –3" SM 10 22 Grey in color 10 a 3/6/8 Slightly Moist Silty Fine Sand with Traces of Clay SM 9 36 Grey in color t - I l S 4/8/13 Silty Fine to Medium Sand SM 2 25 Grey in color - Recovered Sample Total Depth —15' - I Bedrock not encountered 20 Unrecovered Sample Groundwater not encountered - Standard Penetration Sample 25 30 _ Note. The stratification lines represent the approximate 35 boundaries between the soil types; the transition may be - gradual. 40 45 50 Sladden Engineering I sajnsaU asaZ Azo;eiogej gupsa L Xioaeaogel R XIQN3<IJV APPENDIX B LABORATORY TESTING Representative bulk and relatively undisturbed soil samples were obtained in the field and returned to our laboratory for additional observations and testing. Laboratory testing was generally performed in two phases. The first phase consisted of testing in order to determine the compaction of the existing natural soil and the general engineering classifications of the soils underlying the site. This testing was performed in order to estimate the engineering characteristics of the soil and to serve as a basis for selecting samples for the second phase of testing. The second phase consisted of soil mechanics testing. This testing including consolidation, shear strength and expansion testing was performed in order to provide a means of developing specific design recommendations based on the mechanical properties of the soil. CLASSIFICATION AND COMPACTION TESTING Unit Weight and Moisture Content Determinations: Each undisturbed sample was weighed and measured in order to determine its unit weight. A small portion of each sample was then subjected to testing in order to determine its moisture content. This was used in order to determine the dry density of the soil in its natural condition. The results of this testing are shown on the Boring Log. Maximum Density -Optimum Moisture Determinations: Representative soil types were selected for maximum density determinations. This testing was performed in accordance with the ASTM Standard D1557-91, Test Method A. The results of this testing are presented graphically in this appendix. The maximum densities are compared to the field densities of the soil in order to determine the existing relative compaction to the soil. This is shown on the Boring Log, and is useful in estimating the strength and compressibility of the soil. Classification Testing. Soil samples were selected for classification testing. This testing consists of mechanical grain size analyses and Atterberg Limits determinations. These provide information for developing classifications for the soil in accordance with the Unified Classification System. This classification system categorizes the soil into groups having similar engineering characteristics. The results of this testing are very useful in detecting variations in the soils and in selecting samples for further testing. SOIL MECHANIC'S TESTING Direct Shear Testing. One bulk sample was selected for Direct Shear Testing. This testing measures the shear strength of the soil under various normal pressures and is used in developing parameters for foundation design and lateral design. Testing was performed using recompacted test specimens, which were saturated prior to testing. Testing was performed using a strain controlled test apparatus with normal pressures ranging from 800 to 2300 pounds per square foot Expansion Testing: One bulk sample was selected for Expansion testing. Expansion testing was performed in accordance with the UBC Standard 18-2. This testing consists of remolding flinch diameter by 1 -inch thick test specimens to a moisture content and dry density corresponding to approximately 50 percent saturation. The samples are subjected to a surcharge of 144 pounds per square foot and allowed to reach equilibrium. At that point the specimens are inundated with distilled water. The linear expansion is then measured until complete. Consolidation Testing: Four relatively undisturbed samples were selected for consolidation testing. For this testing one -inch thick test specimens are subjected to vertical loads varying from 575 psf to 11520 psf applied progressively. The consolidation at each load increment was recorded prior to placement of each subsequent load. The specimens were saturated at the 575 psf or 720 psf load increment. Project Number: Project Name: Lab ID Number: Sample Location: Description: Maximum Density: Optimum Moisture: 145 140 135 130 Maximum Density/Optimum Moisture ASTM D698/D1557 544-4402 Trans West Housing Bulk 3 @ 0 -5 - Silty Sand 129 pcf 9.5% Sieve Size % Retained 3/4" 3/8'► #4 0.0 August 3, 2004 ASTM D-1557 A Rammer Type: Manual A 120 110 105 100 0 5 10 15 20 25 Moisture Content, % Max Density Sladden Engineering Revised 12/03/02 Maximum Density/Optimum Moisture ASTM D698/D1557 Project Number: 544-4402 Project Name: Ave. 54 & Madison Lab ID Number: Sample Location: Bulk 3 @ 0-5' Description: Silty Sand Maxiinum Density: 119 pcf Optimum Moisture: 10.5% 145 140 135 130 125 0 120 Sieve Size % Retained 3/4" 3/8" #4 0.0 August 30, 2004 ASTM D-1557 A Rammer Type: Manual 110 105 5 10 15 Moisture Content, % 20 25 Max Density Sladden Engineering Revised 12/03/02 Project Number: Project Name: Sample ID: Gradation ASTM C117 & C136 544-4402 Trans West Housing Bulk 3 @ 0-5' Sieve Sieve Percent Size, in Size, mm Passing 111 25.4 100.0 3/4" 19.1 100.0 1/2" 12.7 100.0 3/8" 9.53 100.0 #4 4.75 100.0 #8 2.36 100.0 #16 1.18 97.0 #30 0.60 94.0 #50 0.30 86.0 #100 0.15 75.0 #200 0.074 25.0 August 3, 2004 Gradation Sladden Engineering Revised 11/20/02 1 I I Project Number: Project Name: Sample ID: Gradation ASTM C117 & C136 544-4402 Ave. 54 & Madison Bulk 3 @ 0-5' Sieve 11U���1/I�/r111b� nm�■��I111n■��1111��■�� . un�n■1�■nm �luiln■�■■Ilin�u■1■■■ii��l�n■n� . ` iin�nsii� nal�■���11 u■ni■■n�ln■n■1■ . , till�nnl�■n�m���11111`�■n■■iimn■n■i■riuln■n� i�i�n■�■liiil���nl�n■nln■ml�n■n�i�il�nn� i1n ■�Innn■n■1■In ��l�l�Imnn�uun■■1� ' Sieve Percent Size, in Size, mm Passing 1" 25.4 100.0 3/4" 19.1 100.0 1/2" 12.7 100.0 3/8" 9.53 100.0 #4 4.75 100.0 #8 2.36 99.0 #16 1.18 91.0 #30 0.60 86.0 #50 0.30 71.0 #100 0.15 61.0 #200 0.074 25.0 August 30, 2004 11H 11111111111M nn■n� �� unn■ �ull� MINE � ' iI■■ 111n 1 nnu■� lmilommillllnm= u�nn 11in �111�n■nnln�n■1■1�1111�n■� _- . , i�n� ■■ 1n■n■■Inl�n■��►rnl�n■n�llll�rn� i11���■n�nllmull m n■■lllm►�1Rn■1■�Inl�n■1■1■ lln�n■n�lulln■■limlin■n�r►��In■Ia1il11�no� nn�n■■1 n■mnn■�l�n�u■�u11in■n� iln�nlln�nll��lle�n■lalln�n■n�illl�nu�11� iln�n■■�n11�na�ul�ll■�l1u�n■n■■1i111�u■n�l i111�n■■In■1111nv■nlunn■�nu�n■■1■m1111�n■I■11� u°ni ■■11■�n I�un�nlni�iuii■�t�■11111ini� to , �. , ,,, ,,, . , , . ► , „ Gradation Sladden Engineering Revised 1120/02 Job Number: Job Name: Lab ID: Sample ID: Soil Description: Expansion Index ASTM D 4829/UBC 29-2 5444402 Date: 8/3/2004 Trans West Housing Tech: Jake Bulk 3 @ 0-5' Silty Sand Wt of Soil + Ring: 595.0 Weight of Ring: 179.0 Wt of Wet Soil: 416.0 Percent Moisture: 8% Wet Density, pcf 126.0 Dry Denstiy, pef. 1 116.7 Saturation: 48.7 Expansion Rack # Date/Time 8/4/2004 9:00 AM Initial Reading 0.500 Final Reading 0.511 Expansion Index (Final - Initial) x 1000 1 4 El Sladden Engineering Revised 12/10/02 One Dimensional Consolidation ASTM D2435 & D5333 Job Number: 544-4402 Job Name: Ave. 54 & Madison Sample ID: Boring 9 @ 5' Soil Description: Sandy Silt 1 0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -!- 0.0 August 30, 2004 Initial Dry Density; pcf 88.0 Initial Moisture, %: 10 Initial Void Ratia:r 0.894 G.i Specific Graty: ' 2.67 % Change in Height vs Normal Presssure Diagram 0 Before Saturadon —6 After Saturation i i e—Rebound --E—Hydro Consolidation 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Consolidation Sladden Engineering Revised 11/20/02 One Dimensional Consolidation ASTM D2435 & D5333 Job Number: 544-4402 Job Name: Ave. 54 & Madison Sample ID: Boring 9 @ 10' Soil Description: Sand August 30, 2004 Initial Dry Density, pcf: 99.9 Initial Moisture, %: 2 Initial Void Ratio: 0.669 Specific Gravity: 2.67 % Change in Height vs Normal Presssure Diagram --0 Before Saturation - —After Saturation —9 Rebound —M —Hydro Consolidation 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Consolidation Sladden Engineering Revised 11/20/02 One Dimensional Consolidation ASTM D2435 & D5333 Job Number: 544-4402 Job Name: Ave. 54 & Madison Sample ID: Boring 15 @ 5' Soil Description: Sand -2 A -5 -6 -7 -8 -9 -10 August 30, 2004 Initial Dry Density, pcf 90.7 Initial Moisture, %: 3 Initial Void Ratio: 0.837 Specific Gravity: 2.67 % Change in Height vs Normal Presssure Diagram —0 Before Saturation --6 —After Saturation --e—Rebound --F-Hydro Consolidation 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Consolidation Sladden Engineering Revised 1120/02 One Dimensional Consolidation ASTM D2435 & D5333 Job Number: 544-4402 Job Name: Ave: 54 & Madison Sample ID: Boring 15 @ 10' Soil Description: Silty Sand -4 -5 -6 -7 -8 -9 -10 4- 0.0 August 30, 2004 Initial Dry Density, pcf: 95.9 Initial Moisture, %: 15 Initial Void Ratio: 0.738 Specific Gravity: 2.67 % Change in Height vs Normal Presssure Diagram —0 Before Saturation •-A After Saturation —e—Rebound Hydro Consolidation 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Consolidation Sladden Engineering Revised 11/20102 Expansion Index ASTM D 4829/UBC 29-2 Job Number: 544-4402 Job Name: Ave. 54 & Madison Lab ID: Sample ID: Bulk 3 @ 0-5' Soil Description: Silty Sand Wt of Soil + Ring: 585.0 Weight of Ring: 179.0 Wt of Wet Soil: 406.0 Percent Moisture: 9% Wet Density, pcf: 123.0 Dry Denstiy, pcf 1 112.9 Saturation: 1 49.3 Expansion Rack # Date/Time 8/30/2004 9:00 AM Initial Reading 0.500 Final Reading 0.502 Expansion Index (Final - Initial) x 1000 2 Date: 8/30/2004 Tech: Jake El Sladden Engineering Revised 12/10/02 Project Number: Project Name: Sample ID: Gradation ASTM C117 & C136 544-4402 August 30, 2004 Ave. 54 & Madison Boring 3 @ 5' Sieve Sieve Percent Size, in Size, mm Passing 1" 25.4 100.0 3/4" 19.1 100.0 1/2" 12.7 100.0 3/8" 9.53 100.0 #4 4.75 100.0 #8 2.36 100.0 #16 1.18 97.0 430 0.60 79.0 #50 0.30 68.0 #100 0.15 59.0 #200 0.074 17.0 ' ► ItWIsm=�nun■In�11u111�■1■lnlnunl! 1�■ Illlulml lnn■!�'lnn■n�11u11 I�Itl1ln■! nlln■�m Iln�l�rilmilmomn111i■mmIt111l■m� nlln■ �OIIn��nIm�lImomm11111l■!m IIW■��Illln IIIA. ■OIfl1I�■�mn111�■�� �IHO��iI ��11111►. EM INN IlnmWmn iinninNOR INNIIIIIn■n111■1111�■n� pIWmIn � ll8l I�INMI N I lllunnmlllinn! . ili�■�uA1■IWlllln■ iullmnmtmlt■■111� IIIIR■ In■1m11111W1�ii inllln■■tmnlln■■ IIIIIi 11n �nn■1■■1►�Illnll■■lnlll OM= - 110 MEI IN 111111111,91 iiam llluonm - 111 n11■Imllnn■nlamlm■i1�111Iullnm Illl!l�ltilH�■�llllln■�ml�lliin■lmIt111n■�� It111n!■lllnn■Im llls■■lml►InnlnWln■mulln�n IA11n�1111n■MIll11n■mm1 m11111�0� �1■slilnn■Iminln■■ImIr��In■■1m111111tME Ir�1�■nm nllW■Imltilln■!Im�II 111W■ l�pl�1NIINIQ�W11mm_IIl11n■Ii011/■� ► fill If# off Gmdation Sladden Engineering Revised 11/20/02 Gradation ASTM CI 17 & C136 Project Number: 544-4402 August 30, 2004 Project Name: Ave. 54 & Madison Sample ID: Boring 3 @ 10' Sieve Size, in Sieve Size, mm Percent Passing 1" 25.4 100.0 3/4" 19.1 100.0 1/2" 12.7 100.0 3/8" 9.53 100.0 #4 4.75 100.0 #8 2.36 100.0 #16 1.18 100.0 #30 0.60 86.0 #50 0.30 74.0 #100 0.15 57.0 4200 0.074 21.0 " 111n1I■�rm��Illrlii���mn n■■■nn�n■■■■ ., I1 11■II m■m■nnn■��ill■■1■�1nln■■■■ I11n�1■�il■u�na■1■1u� nlu■■■Ile�n■■■■Illnnl�l■■■ ., Inliu■■■n�ll�ll■■■I�nl��■■Illll�un■■■nll�u■■11■ Inun■■■nnn■■nl■uluu. ■i■Wnu■■■■II�I�■■■1■■ ulm■■■uHim■■�■Inl�ui>i IIn�OEM HIRO■■■ RUIN■■�nllun■I■■IIInll■��iil11111 �INI�u■■�■■ . , nl n■■■unliu■■■nlinn■►�11—■ nnin■■�I lu�la■■ iniu■■1■lnu■■��■Ilmll■■■■IIIpn■■■il 111 linun■■1■Iinn■■ �In1n■■■n111 ■■■i■ Hill OEM Illn■■■�►rllnm■■illl�i■■ Hill 11101111111111111111 11l1I■■=lllll== Ill�n■■■Iln�nllu■ �lmn■■■ilnn = imi■■lunnu■�■u■III■i►n1�IM=Uln■■I■ I�Il�n■■nln I�u■■=lillll�u■n■IllIIu■nIIIE il■■m■■n�nnu■■■I�IIm■■■u��n■n ill �nn■1■ un■■■■nulin■1■nllnn■0■1111n■1�1■ II■■�11nI�n�Wn�■■�11111�■■�11111�■ � Ilion ■■[n11�■ nn�■��illli��■�1�1��= Gradation Sladden Engineering Revised 11/20/02 August 17, 2004 -15- Project No. 544-4402 04-08-571 1997 UNIFORM BUILDING CODE SEISMIC DESIGN INFORMATION The International Conference of Building Officials 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in the updated code that will be relevant to construction of the proposed structures are summarized below. Ground shaking is expected to be the primary hazard most likely to affect the site, based upon proximity to significant faults capable of generating large earthquakes. Major fault zones considered to be most likely to create strong ground shaking at the site are listed below. Fault Zone Approximate Distance From Site Fault Type (1997 UBC) San Andreas 9.9 km A San Jacinto 32.1 km A Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is So, generally described as stiff or dense soil. The site is located within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1997 code. Sladden Engineefing Near -Source Near -Source Seismic Seismic Seismic Acceleration Velocity Coefficient Coefficient Source Factor, Na Factor, Ne Ca C° San Andreas 1.0 1 1.2 0.44Na 0.64N,, San Jacinto 1.0 1 1.0 0.44Na 0.64N,, Sladden Engineefing Engineering IIIIIIIIIIIIIIIIIIIII11175 IE 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895 June 28, 2006 Project No. 522-4402 06-06-667 Trans West Housing, Inc. 10721 Treena Street, #200 San Diego, California 92131 Project: Griffin Ranch Residential Development SEC Avenue 54 and Madison Street La Quinta, California Subject: Report of Observations and Testing During Rough Grading Ref: Geotechnical Investigation Report prepared by Sladden Engineering dated August 17, 2004; Project No. 544-4402, Report No. 04-08-571 Geotechnical Update report prepared by Sladden Engineering dated December 2, 2005; Project No. 544-4402, Report No. 05-11-1133 Summarized in this report are the results of in-place density tests performed at the subject site during the rough grading of the building pads along with pertinent observations. The subject site is located on the south east corner of Avenue 54 and Madison Street in the City of La Quinta, California. The building pad areas were overexcavated to a depth of at least 3 feet below existing grade or 4 feet below pad grade, whichever was deeper. The previously removed native soil, native soil obtained from cut areas of the site and import soil were placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction Observations and field testing was performed from March 13, 2005 to April 10, 2006. Testing indicates that after reworking areas of low density, a minimum of 90 percent relative compaction was attained in the areas tested. The passing test results indicate compliance with the project specifications at the tested locations and depths but are no guarantee or warranty of the contractors work. June 28, 2006 -2- Project No. 522-4402 06-06-667 Field Tests: In-place moisture/density tests were performed using a nuclear density gauge in accordance with test methods ASTM D 2922 and ASTM D 3017. A total of 509 density tests were performed by Sladden Engineering personnel during grading. The approximate test locations are indicated by lot number and on the attached plans and test results are summarized on the attached data sheets. Laboratory Tests: The moisture -density relationships for the tested materials were determined in the laboratory in accordance with test method ASTM D 1557-91. AlIowable Bearing Pressures: The structural values recommended in the referenced Geotechnical Investigation report prepared by Sladden Engineering remain applicable for use in foundation design. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 2 feet below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 1800 psf, respectively. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with Uniform Building Code (UBC) classification criteria. If there are any questions regarding this report or the testing summarized herein, please contact the undersigned. Respectfully submitted SLADDEN ENGINEERING Grading/lh Copies 4/Trans West Housing, Inc. BR ANDERSEN Brett L. Anderson w W_ No. C45389 Exp_ e/30114 Principal Engineer Y�n,RCIVIL Grading/lh Copies 4/Trans West Housing, Inc. TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Density Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 1 03-13-05 Griffin House 2.0 BPG I00.4 16.0 91 110.0 2 03-13-05 Griffin House 2.0 BPG 99.0 18.5 90 110.0 3 03-13-05 Griffin House 2.0 BPG 102.4 7.2 93 110.0 East Wall Footing Backfill . 4 07-14-05 Sta. 7+00 SG 99.6 7.9 91 110.0 5 07-14-05 Sta. # 5+00 2.0 BSG 100.5 10.3 92 110.0 6 07-14-05 Sta. # 4+00 SG 98.7 10.7 90 110.0 7 07-14-05 Sta. # 3+00 2.0 BSG 102.1 6.5 93 110.0 8 07-14-05 Sta. # 1+00 SG 99.9 6.8 91 110.0 9 07-26-05 Sta. # 0+00 SG 98.7 10.2 90 110.0 10 07-26-05 Sta. # 0+00 SG 100.0 10.6 91 110.0 Building Pads 11 08-09-05 Lot 50 6.0 BPG 106.2 5.7 93 114.0 12 08-09-05 Lot 50 4.0 BPG 107.2 7.4 94 114.0 13 08-09-05 Lot 49 6.0 BPG 103.5 9.0 91 114.0 14 08-09-05 .Lot 49 4.0 BPG 103.9 7.5 91 114.0 15 08-12-05 Lot 288 4.0 BPG 109.3 10.2 96 114.0 16' 08-12-05 Lot 288 2.0 BPG 102.6 8.2 02 114.0 17 08-12-05 Lot 287 4.0 BPG 104.6 12.4 92 114.0 18 08-12-05 Lot 287 2.0 BPG 104.0 10.9 91 114.0 19 08-15-05 Lot 302 3.0 BPG I06.6 7.4 94 114.0 20 08-15-05 Lot 302 1.0 BPG 105.2 6.8 92 114.0 21 08-15-05 Lot 300 4.0 BPG 106.3 5.8 93 114.0 22 08-15-05 Lot 300 2.0 BPG 107.0 5.4 94 114.0 23 08-17-05 Lot 52/51 4.0 BPG 105.0 7.6 96 110.0 24 08-17-05 Lot 52/51 2.0 BPG 105.1 8.6 96 110.0 25 08-17-05 Lot 302 4.0 BPG 107.2 12.2 97 110.0 26 08-17-05 Lot 302 2.0 BPG 107.8 9.0 98 110.0 Wall Footing Backfill - South Wall 27 08-19-05 Sta. # 11+00 SG 104.5 18.8 92 114.0 28 08-19-05 Sta. # 12+50 SG 110.2 12.7 98 114.0 29 08-19-05 Sta. # 14+00 SG 106.3 14.0 93 114.0 30 08-19-05 Sta. # 15+50 SG 104.1 14.8 91 114.0 31 08-19-05 Sta. # 17+00 SG 102.6 13.2 90 114.0 32 08-19-05 Sta. # 18+50 SG 104.4 12.9 92 114.0 DATE: June 29, 2006 Sladden EurineeriirLy TEST RE, SULTS PROTECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Densitv Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Wall Footing Backfill - South Wall 33 08-19-05 Sta. # 20+00 SG 108.3 8.3 96 114.0 34 08-19-05 Sta. # 21+50 SG 104.0 8.8 91 114.0 Building Pads 35 08-23-05 Lot 291 4.0 BPG 104.0 12.4 91 114.0 36 08-23-05 Lot 291 2.0 BPG 104.1 6.6 91 114.0 37 08-26-05 Lot 298 6.0 BPG 106.9 14.2 94 114.0 38 08-26-05 Lot 298 4.0 BPG 107.3 12.6 94 114.0 39 08-26-05 Lot 298 2.0 BPG 110.5 13.4 97 114.0 40 08-26-05 Lot 296 6.0 BPG 111.0 13.3 97 114.0 41 08-26-05 Lot 296 4.0 BPG 110.3 13.1 97 114.0 42 08-26-05 Lot 296 2.0 BPG 106.3 12.7 93 114.0 43 08-26-05 Lot 285 PG 107.7 11.4 95 114.0 44 08-26-05 Lot 286 PG 112.7 11.8 99 114.0 45 08-26-05 Lot 287 PG 105.8 6.4 93 114.0 46 08-26-05 Lot 288 PG 105.8 9.2 93 114.0 47 08-29-05 Lot 291 PG 99.9 6.5 91 110.0 48 08-29-05 Lot 290 PG 106.9 6.5 97 110.0 49 08-29-05 Lot 289 PG 102.6 7.0 93 110.0 50 08-31-05 Lot 46 PG 106.4 9.8 97 114.0 51 08-31-05 Lot 50 PG 108.9 8.6 99 114.0 52 08-31-05 Lot 300 PG 108.6 10.0 99 114.0 53 08-31-05 Lot 299 PG 108.9 11.2 99 114.0 54 09-01-05 Lot 298 4.0 BPG 99.6 8.4 91 111.0 55 09-01-05 Lot 298 2.0 BPG 105.2 13.8 96 111.0 56 09-01-05 Lot 296 4.0 BPG 101.7 16.7 93 110.0 57 09-01-05 Lot 296 2.0 BPG 106.6 12.3 97 110.0 58 09-02-05 Lot 284 6.0 BPG 107.9 10.1 98 110.0 59 09-02-05 Lot 284 4.0 BPG 105.0 19.0 96 110.0 60 09-02-05 Lot 284 2.0 BPG I07.7 16.5 98 110.0 61 09-02-05 Lot 282 6.0 BPG 107.1 16.4 97 110.0 62 09-02-05 Lot 282 4.0 BPG 106.3 13.0 97 110.0 63 09-02-05 Lot 282 2.0 BPG 106.2 19.1 97 110.0 64 09-02-05 Lot 281 6.0 BPG 107.8 14.9 98 110.0 65 09-02-05 Lot 281 4.0 BPG 108.6 12.2 99 110.0 66 09-02-05 Lot 281 2.0 BPG 104.7 15.2 95 110.0 DATE: June 29, 2006 Sladden Engineering TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Density Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 67 09-06-05 Lot 292 PG 109.1 5.60 99 110.0 68 09-06-05 Lot 293 PG 101.4 6.5 92 110.0 69 09-06-05 Lot 294 PG 103.6 6.7 94 110.0 70 09-06-05 Lot 295 PG 106.0 10.4 97 110.0 71 09-08-05 Lot 46 4.0 BPG 106.6 11.1 97 110.0 72 09-08-05 Lot 46 2.0 BPG 108.4 12.1 98 110.0 73 09-08-05 Lot 48 4.0 BPG 109.1 9.1 99 110.0 74 09-08-05 Lot 48 2.0 BPG 103.3 7.7 94 110.0 75 09-08-05 Lot 298 PG 108.1 11.2 98 110.0 76 09-08-05 Lot 297 PG 107.5 12.4 98 110.0 77 09-08-05 Lot 296 PG 108.9 11.4 99 110.0 78 09-09-05 Lot 301 PG 103.6 5.2 94 110.0 79 09-09-05 Lot 302 PG 103.8 8.9 94 110.0 80 09-09-05 Lot 301 PG 103.4 7.6 97 110.0 81 09-12-05 Lot 51 PG 101.9 8.7 93 110.0 82 09-12-05 Lot 52 PG 101.3 6.2 92 110.0 83 09-14-05 Lot 276 6.0 BPG 104.4 15.4 95 110.0 84 09-14-05 Lot 276 4.0 BPG 107.5 17.4 98 110.0 85 09-14-05 Lot 276 2.0 BPG 108.1 14.4 98 110.0 86 09-14-045 Lot 278 5.0 BAG 105.6 16.1 97 110.0 87 09-14-05 Lot 278 3.0 BPG 109.1 11.1 99 110.0 88 09-14-05 Lot 278 1.0 BPG 108.8 12.7 99 110.0 89 09-14-05 Lot 258 6.0 BPG 103.3 14.6 94 110.0 90 09-14-05 Lot 258 4.0 BPG 100.4 8.6 92 110.0 91 09-14-05 Lot 258 2.0 BPG 104.1 I2.2 95 110.0 92 09-14-05 Lot 260 6.0 BPG 106.7 17.2 96 110.0 93 09-14-05 Lot 260 4.0 BPG 108.5 6.9 99 110.0 94 09-14-05 Lot 260 2.0 BPG 102.5 12.2 93 110.0 95 09-14-05 Lot 54 5.0 BPG 109.1 15.1 99 110.0 96 09-14-05 Lot 54 3.0 BPG 109.9 12.9 98 110.0 97 09-14-05 Lot 54 1.0 BPG 104.8 10.2 95 110.0 98 09-14-05 Lot 274 6.0 BPG 104.7 11.2 95 110.0 99 09-14-05 Lot 274 4.0 BPG 107.4 14.5 98 110.0 100 09-14-05 Lot 274 2.0 BPG 104.0 16.7 95 110.0 DATE: June 29, 2006 Sladden ErrQirreerine TEST RESULTS PROJECT NAND: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Density Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction BUILDING Pads 101 09-14-05 Lot 48 PG 104.7 12.5 95 110.0 102 09-14-05 Lot 47 PG 106.0 8.6 97 110.0 103 09-14-05 Lot 46 PG 108.9 7.7 98 110.0 104 09-16-05 Lot 257 6.0 BPG 104.2 10.1 95 110.0 105 09-16-05 Lot 255 6.0 BPG 102.1 9.6 93 110.0 106 09-16-05 Lot 253 6.0 BPG 102.2 11.4 93 110.0 107 09-20-05 Lot 279 PG 108.7 11.3 99 110.0 108 09-20-05 Lot 280 PG 109.2 7.1 99 110.0 109 09-20-05 Lot 281 PG 108.9 15.4 99 110.0 110 09-20-05 Lot 282 PG 108.5 14.7 99 110.0 111 09-20-05 Lot 283 PG 109.0 10.9 99 110.0 112 09-20-05 Lot 284 PG 102.6 11.7 93 110.0 113 09-21-05 Lot 51 PG 108.7 10.6 99 110.0 114 09-21-05 Lot 52 PG 107.7 12.9 98 110.0 115 09-21-05 Lot 45 PG 109.1 11.4 99 110.0 116 09-21-05 Lot 44 PG 109.1 10.5 99 110.0 117 09-21-05 Lot 46 PG 108.8 12.6 99 110.0 118 09-22-05 Lot 261 6.0 BPG 104.2 14.4 95 110.0 119 09-22-05 Lot 261 4.0 BPG 106.8 13.1 97 110.0 120 09-22-04 Lot 261 2.0 BPG 105.3 9.1 96 110.0 121 09-22-05 Lot 263 5.0 BPG 102.2 11.5 93 110.0 122 09-22-05 Lot 263 3.0 BPG 102.0 9.8 93 1110.0 123 09-22-05 Lot 263 1.0 BPG 105.0 11.8 96 110.0 124 09-22-05 Lot 256 5.0 BPG 102.4 11.8 93 110.0 125 09-22-05 Lot 256 3.0 BPG 102.2 13.6 93 110.0 126 09-22-05 Lot 256 1.0BPG 104.1 13.5 95 110.0 127 09-22-05 Lot 254 6.0 BPG 100.8 14.4 92 110.0 128 09-22-05 Lot 254 4.0 BPG 103.8 14.1 94 110.0 129 09-22-05 Lat 254 2.0 BPG 102.6 14.6 93 110.0 130 09-26-05 Lot 257 PG 108.8 7.3 99 110.0 131 09-26-05 Lot 256 PG 103.0 10.8 94 110.0 132 09-26-05 Lot 255 PG 103.0 11.4 94 110.0 133 09-26-05 Lot 254 PG 104.8 6.7 95 110.0 134 09-26-05 Lot 253 PG 107.2 6.7 97 110.0 135 09-26-05 Lot 252 PG 101.3 5.6 92 110.0 DATE: June 29, 2006 Sladdett Etteineeritts TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Densitv Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 136 09-26-05 Lot 278 PG 98.5 7.7 90 110.0 137 09-26-05 Lot 258 PG 102.7 7.2 93 110.0 138 09-26-05 Lot 259 PG 102.8 6.4 93 110.0 Compaction on Overexcavation 139 09-27-05 6.0 BPG 102.2 6.2 93 110.0 140 09-27-05 4.0 BPG 1.03.0 10.2 94 110.0 141 09-27-05 2.0 BPG 104.6 11.8 95 110.0 142 09-27-05 6.0 BPG 102.0 14.6 93 110.0 143 09-27-05 4.0 BPG 106.2 10.7 97 110.0 144 09-27-05 2.0 BPG 106.4 10.8 97 110.0 145 09-27-05 6.0 BPG 108.6 11.7 99 110.0 146 09-27-05 4.0 BPG 108.6 9.1 99 110.0 147 09-27-05 2.0 BPG 109.I 9.9 99 110.0 Building Pads 148 09-28-05 Lot 261 PG 104.5 8.4 95 110.0 149 09-28-05 Lot 262 PG 108.7 10.4 99 110.0 150 09-28-05 Lot 263 PG 108.7 10.1 99 110.0 151 09-28-05 Lot 264 PG 106.0 10.0 97 110.0 152 09-29-05 Lot 236 8.0 BPG 109.2 7.2 99 110.0 153 09-29-05 Lot 237 8.0 BPG 98.8 13.6 90 110.0 154 09-29-05 Lot 238 8.0 BPG 99.1 8.2 90 110.0 155 09-29-05 Lot 239 8.0 BPG 98.5 10.7 90 110.0 156 09-29-05 Lot 240 8.0 BPG 101.6 14.5 92 110.0 157 09-29-05 Lot 241 8.0 BPG 98.8 5.2 90 110.0 158 09-29-05 Lot 242 8.0 BPG 100.1 6.8 91 110.0 159 09-29-05 Lot 243 8.0 BPG 99.6 11.4 91 110.0 160 09-29-05 Lot 244 8.0 BPG 101.8 14.6 92 110.0 161 09-29-05 Lot 245 8.0 BPG 98.7 15.1 90 110.0 162 09-29-05 Lot 246 8.0 BPG 101.1 11.1 92 110.0 163 09-29-05 Lot 247 8.0 BPG 98.6 9.2 90 110.0 164 09-29-05 Lot 248 8.0 BPG 99.1 12.6 91 110.0 165 09* -29-05 Lot 249 8.0 BPG 98.8 15.4 90 110.0 166 09-29-05 Lot 53 PG 108.7 7.2 99 110.0 167 09-29-05 Lot 274 PG 103.2 7.1 94 110.0 168 09-29-05 Lot 275 PG 101.9 12.6 93 110.0 169 09-29-05 Lot 276 PG 103.8 7.2 94 110.0 170 09-29-05 1 Lot 277 PG 105.1 6.2 96 110.0 DATE: June 29, 2006 Sladden Eiteiiteerbw TEST RESULTS PROM CT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Densitv Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 171 09-29-05 Lot 260 PG 109.0 6.3 99 110.0 172 09-29-05 Lot 273 PG 108.4 10.9 98 110.0 173 09-29-05 Lot 272 PG 104.2 7.5 95 110.0 174 09-29-05 Lot 271 PG 105.6 6.9 96 110.0 175 10-04-05 Lot 268 PG 103.6 10.1 94 110.0 176 10-04-05 Lot 267 PG 108.1 9.6 98 110.0 177 10-04-05 .Lot 266 PG 107.4 11.4 97 110.0 178 10-04-05 Lot 265 PG 103.8 10.6 94 110.0 179 10-04-05 Lot 270 PG 105.6 9.2 96 110.0 180 10-04-05 Lot 269 PG 109.1 9.0 99 110.0 181 10-04-05 Lot 54 PG 108.8 9.9 99 110.0 182 10-04-05 Lot 55 PG 103.6 11.45 94 110.0 183 10-04-05 Lot 242 4.0 BPG 100.7 14.2 92 110.0 184 10-04-05 Lot 242 2.0 BPG 104.0 11.3 95 110.0 185 10-04-05 Lot 244 4.0 BPG 104.6 13.2 95 110.0 186 10-04-05 Lot 244 2.0 BPG 109.1 9.6 99 110.0 187 10-04-05 Lot 246 4.0 BPG 100.1 18.9 91 110.0 188 10-04-05 Lot 246 2.0 BPG 117.0 14.4 97 110.0 189 10-04-05 Lot 248 4.0 BPG 105.4 7.5 96 110.0 190 10-04-05 Lot 248 2.0 BPG 102.1 7.5 93 110.0 191 10-05-05 Lot 43 PG 102.6 6.8 93 110.0 192 10-05-05 Lot 42 PG 107.0 6.1 97 110.0 193 10-05-05 Lot 41 PG 102.7 7.0 93 110.0 194 10-05-05 Lot 56 PG 104.5 8.1 95 110.0 195 10-05-05 Lot 233 7.0 BPG 104.9 10.0 95 110.0 196 10-05-05 Lot 233 5.0 BPG 100.7 11.9 92 110.0 197 10-05-05 Lot 235 7.0 BPG 99.5 12.7 91 110.0 198 10-05-05 Lot 235 5.0 BPG 103.2 11.1 94 110.0 199 10-05-05 Lot 237 7.0 BPG 107.0 13.5 97 110.0 200 10-05-05 Lot 237 5.0 BPG 99.8 15.6 91 110.0 201 10-07-05 Lot 249 PG 100.2 8.8 91 110.0 202 10-07-05 Lot 248 PG 104.8 7.5 95 110.0 203 10-07-05 Lot 247 PG 101.9 6.6 93 110.0 204 10-07-05 Lot 246 PG 104.5 5.9 95 110.0 205 10-07-05 Lot 245 PG 103.5 15.3 94 110.0 206 10-07-05 Lot 244 PG 100.9 10.5 92 110.0 DATE: June 29, 2006 Sladdett Enzineerittz TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Density Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 207 10-07-05 Lot 243 PG 100.5 8.8 92 110.0 208 10-11-05 Lot 220 4.0 BPG 107.9 13.2 96 112.0 209 10-11-05 Lot 220 2.0 BPG 108.0 10.9 96 112.0 210 10-11-05 Lot 227 3.0 BPG 103.8 7.9 92 112.0 211 10-11-05 Lot 227 1.0 BPG 108.7 9.9 96 112.0 212 10-11-05 Lot 229 3.0 BPG 109.0 11.9 97 112.0 213 10-11-05 Lot 229 1.0 BPG 106.0 7.2 95 110.0 214 10-13-05 Lot 218 6.0 BPG 103.8 13.4 94 110.0 215 10-13-05 Lot 218 4.0 BPG 102.1 12.6 93 110.0 216 10-13-05 Lot 218 2.0 BPG 107.7 11.4 98 110.0 217 10-13-05 Lot 216 6.0 BPG 100.4 11.6 92 110.0 2I8 10-13-05 Lot 216 4.0 BPG 104.1 10.2 95 110.0 219 10-13-05 Lot 216 2.0 BPG 106.6 12.2 97 110.0 220 10-13-05 Lot 220 6.0 BPG 102.8 14.1 93 110.0 221 10-13-05 Lot 220 4.0 BPG 102.5 13.1 93 110.0 222 10-13-05 Lot 220 2.0 BPG 106.1 11.4 97 110.0 223 10-13-05 Lot 252 PG 106.8 12.1 97 110.0 224 10-13-05 Lot 254 PG 108.8 9.4 99 110.0 225 10-13-05 Lot 250 PG 108.5 10.2 99 110.0 226 10-25-05 Lot 217 PG 107.2 9.8 97 110.0 227 10-25-05 Lot 218 PG 103.1 11.1 94 110.0 228 10-25-05 Lot 219 PG 103.4 11.1 94 110.0 229 10-15-05 Lot 220 PG 102.7 10.8 93 110.0 230 10-25-05 Lot 221 PG 100.9 8.5 92 110.0 231 10-25-05 Lot 227 PG 104.6 9.3 95 110.0 232 10-25-05 Lot 228 PG 103.9 8.1 95 110.0 233 10-25-05 Lot 229 PG 106.0 9.6 96 110.0 234 10-25-05 Lot 230 PG 101.4 9.8 92 110.0 235 10-25-05 Lot 233 6.0 BPG 103.6 11.6 94 110.0 236 10-25-05 Lot 233 4.0 BPG 101.8 11.4 93 110.0 237 10-25-05 Lot 233 2.0 BPG 101.7 13.6 93 110.0 238 10-25-05 Lot 235 6.0 BPG 100.6 10.2 92 110.0 239 10-25-05 Lot 235 4.0 BPG 104.1 11.8 95 110.0 240 10-25-05 Lot 235 2.0 BPG 104.6 12.1 95 110.0 241 10-28-05 Lot 233 PG 105.7 12.5 96 110.0 242 10-28-05 Lot 234 PG 109.0 9.9 99 110.0. 243 10-28-05 Lot 235 PG 108.2 14.5 98 110.0 DATE: June 29, 2006 Sladdo» F.trainoori»a TEST RE, SULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Location Elevation Dry Density % Moisture Relative Maximum Densi In Place In Place Compaction Building Pads 244 10-28-05 Lot 236 PG 105.7 12.5 96 110.0 245 10-28-05 Lot 237 PG 105.7 11.8 96 110.0 246 10-28-05 Lot 238 PG 108.3 9.8 98 110.0 247 10-28-05 Lot 239 PG 101.9 15.2 92 110.0 248 10-28-05 Lot 240 PG 106.6 10.0 97 110.0 249 10-28-05 Lot 241 PG 105.4 9.3 96 110.0 250 10-28-05 Lot 242 PG 105.2 8.2 96 110.0 251 10-28-05 Lot 243 PG 108.1 10.6 98 110.0 252 10-31-05 Lot 232 4.0 BPG 106.6 14.2 97 110.0 253 10-31-05 Lot 232 2.0 BPG 108.1 15.0 98 110.0 254 10-31-05 Lot 225 4.0 BPG 105.6 15.6 96 110.0 255 10-31-05 Lot 225 2.0 BPG 107.1 14.3 97 110.0 256 10-31-05 Lot 223 4.0 BPG 108.1 15.5 98 110.0 257 10-31-05 Lot 223 2.0 BPG 108.4 15.1 98 110.0 258 11-14-05 Lot 212 6.0 BPG 108.0 14.5 98 110.0 259 11-14-05 Lot 212 4.0 BPG 102.9 12.8 93 110.0 260 11-14-05 Lot 210 6.0 BPG 104.5 7.6 95 110.0 261 11-14-05 Lot 210 4.0 BPG 101.5 10.8 92 110.0 262 11-14-05 Lot 204 6.0 BPG 106.2 15.2 97 110.0 263 11-14-05 Lot 204 4.0 BPG 104.8 15.5 95 110.0 264 11-14-05 Lot 202 6.0 BPG 109.1 14.1 99 110.0 265 11-14-02 Lot 202 4.0 BPG 106.1 10.2 97 110.0 266 11-16-05 Lot 226 PG 103.2 8.7 94 110.0 267 11-16-05 Lot 225 PG 101.4 17.4 92 110.0 268 11-16-05 Lot 224 PG 103.1 9.9 94 110.0 269 11-21-05 Lot 215 PG 108.6 11.4 99 110.0 270 11-21-05 Lot 214 PG 104.6 12.9 95 110.0 271 11-21-05 Lot 213 PG 108.6 11.1 99 110.0 272 11-21-05 Lot 216 PG 102.8 13.4 93 110.0 273 11-21-05 Lot 57 PG 104.4 9.6 93 110.0 274 11-21-05 Lot 58 PG 106.8 12.1 97 110.0 275 11-21-05 Lot 59 PG 108.8 10.4 99 110.0 276 11-21-05 Lot 60 PG 108.9 12.1 99 110.0 277 11-21-05 Lot 212 PG 102.6 11.2 93 110.0 278 11-21-05 Lot 211 PG 102.4 16.4 93 110.0 279 11-21-05 Lot 210 PG 100.9 7.0 92 110.0 DATE: June 29, 2006 TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Densitv Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 280 11-22-05 Lot 209 PG 108.1 11.2 98 110.0 281 11-29-05 Lot 191 6.0 BPG 101.6 11.8 93 110.0 282 11-29-05 Lot 191 4.0 BPG 100.4 12.0 92 110.0 283 11-29-05 Lot 191 2.0 BPG 102.9 13.4 93 110.0 284 11-29-05 Lot 64 6.0 BPG 102.6 14.6 93 110.0 285 11-29-05 Lot 64 4.0 BPG 101.8 12.8 93 110.0 286 11-29-05 Lot 64 2.0 BPG 104.1 I2.5 95 110.0 287 11-29-15 Lot 193 6.0 BPG 104.1 13.6 95 110.0 288 11-29-05 Lot 193 4.0 BPG 100.1 15.8 91 110.0 289 11-29-05 Lot 193 2.0 BPG 104.5 14.2 95 110.0 290 11-29-05 Lot 202 PG 107.8 10.1 98 110.0 291 11-29-05 Lot 203 PG 105.7 10.7 96 110.0 292 11-29-05 Lot 204 PG 104.6 13.9 95 110.0 293 11-29-05 Lot 205 PG 104.2 14.1 95 110.0 294 11-29-05 Lot 35 6.0 BPG 103.6 12.4 94 110.0 295 11-29-05 Lot 35 4.0 BPG 101.9 12.5 93 110.0 296 11-29-05 Lot 35 2.0 BPG 104.1 14.1 95 110.0 297 11-29-05 Lot 33 6.0 BPG 100.8 13.9 92 110.0 298 11-29-03 Lot 33 4.0 BPG 103.8 11.4 94 110.0 299 11-29-03 Lot 33 2.0 BPG 100.9 14.7 92 110.0 300 12-01-05 Lot 64 4.0 BPG 108.2 12.1 98 110.0 301 12-01-05 Lot 64 2.0 BPG 109.1 11.4 99 110.0 302 12-01-05 Lot 192 4.0 BPG 100.9 13.6 92 110.0 303 12-01-05 Lot 192 2.0 BPG 103.1 12.2 94 110.0 304 12-01-05 Lot 194 4.0 BPG 102.1 14.6 93 110.0 305 12-01-05 Lot 194 2.0 BPG 104.2 13.9 95 110.0 306 12-01-05 Lot 188 4.0 BPG 101.8 11.4 93 110.0 307 12-01-05 Lot 188 2.0 BPG 101.7 13.8 93 110.0 308 12-01-05 Lot 190 4.0 BPG 104.2 11.8 95 110.0 309 12-01-05 Lot 190 2.0 BPG 103.8 13.9 95 110.0 310 12-01-05 Lot 201 PG 109.2 13.4 99 114.0 311 12-01-05 Lot 200 PG 106.7 12.5 97 114.0 312 12-01-05 Lot 199 PG 103.5 8.1 94 114.0 313 12-01-05 Lot 198 PG 105.0 8.6 95 114.0 314 12-02-05 Lot 64 PG 104.8 5.8 95 110.0 315 12-02-05 Lot 63 PG 108.0 15.6 98 110.0 316 12-02-05 Lot 62 PG 108.9 12.1 99 110.0 DATE: June 29, 2006 Slaililei: F.nvinaerinn TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Density Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 317 12-06-05 Lot 191 4.0 BPG 101.8 13.6 93 110.0 318 12-06-05 Lot 191 2.0 BPG 104.1 12.8 95 110.0 319 12-06-05 Lot 193 4.0 BPG 103.7 14.1 94 110.0 320 12-06-05 Lot 193 2.0 BPG 104.5 14.0 95 110.0 321 12-06-05 Lot 187 5.0 BPG 100.9 15.1 92 110.0 322 12-06-05 Lot 187 3.0 BPG 103.6 14.6 94 110.0 323 12-06-05 Lot 187 1.0 BPG 102.8 12.6 93 110.0 324 12-06-05 Lot 189 4.0 BPG 104.6 12.8 95 110.0 325 12-06-05 Lot 189 2.0 BPG 106.7 13.8 97 110.0 326 12-07-05 Lot 64 PG 99.8 9.5 91 114.0 327 12-07-05 Lot 191 PG 104.4 10.9 95 114.0 328 12-07-05 Lot 192 PG 107.8 13.2 98 114.0 329 12-07-05 Lot 193 PG 107.9 11.1 98 114.0 330 12-07-05 Lot 194 PG 105.7 8.6 97 114.0 331 12-08-05 Lot 187 PG 100.6 9.1 92 110.0 332 12-08-05 Lot 188 PG 108.9 9.4 99 110.0 333 12-08-05 Lot 189 PG 103.3 11.1 94 110.0 334 12-08-05 Lot 190 PG 107.2 12.4 98 110.0 335 12-08-05 Lot 65 PG 108.4 11.4 98 110.0 336 12-08-05 Lot 139 PG 101.6 7.0 92 110.0 337 12-08-05 Lot 140 PG 106.8 12.4 97 110.0 338 12-08-05 Lot 141 PG 100.1 7.5 91 110.0 339 12-08-05 Lot 142 PG 105.0 14.1 95 110.0 340 12-08-05 Lot 143 PG 104.2 6.2 95 110.0 341 12-08-05 Lot 144 PG 103.0 11.8 94 110.0 342 12-08-05 Lot 139 5.0 BPG 103.4 11.4 94 110.0 343 12-08-05 Lot 139 2.0 BPG 103.5 13.8 94 110.0 344 12-08-05 Lot 141 4.0 BPG 100.1 13.6 92 110.0 345 12-08-05 Lot 141 2.0 BPG 104.1 13.8 95 110.0 346 12-08-05 Lot 143 4.0 BPG 101.9* 11.6 93 110.0 347 12-08-05 Lot 143 2.0 BPG 103.1 9.6 96 110.0 348 12-08-05 Lot 144 4.0 BPG 104.6 14.4 95 110.0 349 12-08-05 Lot 144 2.0 BPG 105.7 12.2 96 110.0 350 12-09-05 Lot 180 4.0 BPG 103.4 13.3 94 110.0 351 12-09-05 Lot 180 2.0 BPG 107.0 12.6 97 110.0 352 112-09-05 Lot 182 4.0 BPG 101.8 14.6 93 110.0 353 12-09-05 Lot 182 2.0 BPG 103.4 10.2 94 110.0 DATE: June 29, 2006 Sladden Eneineerbw TEST RE, SULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test No. Date Tested Location Elevation Density Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 354 12-09-05 Lot 175 4.0 BPG 100.0 14.8 91 110.0 355 12-09-05 Lot 175 2.0 BPG 105.4 13.6 96 110.0 356 12-09-05 Lot 177 4.0 BPG 104.1 12.8 95 110.0 357 I2-09-05 Lot 177 2.0 BPG 104.8 12.5 95 110.0 358 12-09-05 Lot 179 4.0 BPG 101.6 11.4 92 110.0 359 12-09-05 Lot 179 2.0 BPG 102.4 10.6 97 110.0 360 12-13-05 Lot 68 4.0 BPG 100.0 11.8 91 110.0 361 12-13-05 Lot 68 2.0 BPG 101.1 9.6 92 110.0 362 12-13-05 Lot 136 4.0 BPG 103.6 13.1 94 110.0 363 12-13-05 Lot 136 2.0 BPG 105.6 9.9 96 110.0 364 12-13-05 Lot 134 4.0 BPG 104.1 14.2 95 110.0 365 12-13-05 Lot 134 2.0 BPG 103.1 10.8 94 110.0 366 12-13-05 Lot 132 4.0 BPG 101.9 12.6 93 110.0 367 12-13-05 Lot 132 2.0 BPG 103.8 11.4 94 110.0 368 12-13-05 Lot 129 4.0 BPG 108.1 14.1 98 110.0 369 12-13-05 Lot 129 2.0 BPG 108.0 14.0 98 110.0 370 12-13-05 Lot 127 4.0 BPG 106.7 13.6 97 110.0 371 12-13-05 Lot 127 2.0 BPG 107.7 10.9 98 110.0 372 12-13-05 Lot 125 4.0 BPG 105.1 9.8 96 110.0 373 12-13-05 Lot 125 2.0 BPG 104.1 11.6 95 110.0 374 12-14-05 Lot 138 PG 106.7 11.2 97 110.0 375 12-14-05 Lot 68 PG 108.2 10.8 98 110.0 376 12-14-05 Lot 67 PG 108.7 11.4 99 110.0 377 12-14-05 Lot 66 PG 106.7 12.1 97 110.0 378 12-14-05 Lot 137 PG 108.2 11.8 98 110.0 379 12-14-05 Lot 136 PG 102.2 13.2 93 110.0 380 12-14-05 Lot 135 PG 105.1 11.1 96 110.0 381 12-14-05 Lot 134 PG 99.4 8.7 90 110.0 382 12-14-05 Lot 133 PG 102.9 10.2 93 110.0 383 12-14-05 Lot 132 PG 102.4 6.7 93 110.0 384 12-14-05 Lot 131 PG 105.0 7.6 96 110.0 385 12-14-05 Lot 180 PG 108.1 10.1 98 110.0 386 12-14-05 Lot 181 PG 105.4 9.6 96 110.0 387 12-14-05 Lot 182 PG 107.7 11.4 98 110.0 388 12-14-05 Lot 183 PG 108.6 10.4 99 110.0 389 12-14-05 Lot 175 PG 103.4 11.4 94 110.0 390 12-14-05 Lot 176 PG 108.7 12.2 99 110.0 391 12-14-05 Lot 177 PG 107.1 10.8 97 110.0 392 12-14-05 1 Lot 178 PG 106.8 11.9 97 110.0 DATE: June 29, 2006 Sladdeit Eowhreeriu:n t TEST RESULTS PROJECT NAME-: Griffin Ranch LOCATION: La Quinta, California PROM CT NO: 5224402 REPORT NO: 06-06-667 Test No. I Date Tested Densitv Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 393 12-14-05 Lot 179 PG 108.8 9.8 99 110.0 394 12-15-05 Lot 123 PG 99.4 8.2 90 110.0 395 12-15-05 Lot 124 PG 99.8 8.8 91 110.0 396 12-15-05 Lot 113 PG 100.8 6.4 92 110.0 397 12-15-05 Lot 114 PG 99.6 7.9 91 110.0 398 12-15-05 Lot 115 PG 103.8 12.7 94 110.0 399 12-15-05 Lot 116 PG 104.8 8.4 95 110.0 400 12-15-05 Lot 117 PG 103.2 11.4 94 110.0 401 12-15-05 Lot 118 PG 103.4 12.5 94 110.0 402 12-15-05 Lot 125 PG 99.6 7.9 91 110.0 403 12-15-05 Lot 126 PG 101.1 9.8 92 110.0 404 12-15-05 Lot 127 PG 100.2 11.4 91 110.0 405 12-15-05 Lot 128 PG 99.1 13.6 90 110.0 406 12-15-05 Lot 129 PG 101.0 8.2 91 110.0 407 12-I5-05 Lot 130 PG 103.1 10.6 94 110.0 408 12-15-05 Lot 119 PG 103.2 6.6 94 110.0 409 12-15-05 Lot 120 PG 104.2 7.7 95 110.0 410 12-15-05 Lot 121 PG 102.5 9.6 93 110.0 411 12-15-05 Lot 122 PG 100.9 6.5 92 110.0 412 12-28-05 Lot 154 PG 103.3 11.4 94 110.0 413 12-28-05 Lot 153 PG I04.3 11.9 95 110.0 414 12-28-05 Lot 152 PG 106.2 12.2 96 110.0 415 12-28-05 Lot 145 PG 105.1 11.4 96 110.0 416 12-28-05 Lot 146 PG 99.8 11.6 91 110.0 417 12-28-05 Lot 147 PG 102.8 8.8 93 110.0 418 12-28-05 Lot 107 PG 101.7 9.0 93 110.0 419 12-28-05 Lot 108 PG 106.8 12.1 97 110.0 420 12-28-05 Lot 109 PG 103.4 10.2 94 110.0 421 12-28-05 Lot 110 PG 99.7 10.6 91 110.0 422 12-28-05 Lot 111 PG 102.4 9.0 93 110.0 423 12-28-05 Lot 112 PG 101.0 10.4 92 110.0 424 12-28-05 Lot 72 PG 104.5 11.9 95 110.0 425 12-28-05 Lot 69 PG 102.5 9.2 93 110.0 426 12-28-05 Lot 70 PG 99.0 8.0 90 110.0 427 12-28-05 Lot 71 PG 106.6 11.2 97 110.0 428 12-29-05 Lot 106 PG 99.2 5.7 90 110.0 429 12-29-05 Lot 105 PG 108.2 12.3 98 110.0 430 12-29-05 Lot 104 PG 108.2 10.6 98 110.0 DATE: June 29, 2006 .Gnddon F.noisroorino TEST RESULTS PROJECT NAME: Grim Ranch LOCATION: La Quinta, California PROJECT NO: 522-4402 REPORT NO: 06-06-667 Test NTDensi DateTested Location Elevation Dry Density %o Moisture In Place Relative Maximum In Place Compaction Building Pads 431 12-29-05 Lot 103 PG 101.3 12.4 92 110.0 432 12-29-05 Lot 102 PG 102.5 12.5 93 110.0 Retaining Wall Backfill 433 01-03-06 West of M. Griffin's House PG 99.1 12.5 90 110.0 434 01-03-06 West of M. Griffin's House PG 99.8 13.1 91 110.0 435 01-03-06 West of M. Griffin's House PG 100.0 9.7 91 110.0 436 01-03-06 M. Griffin's House 4.0 BPG 103.3 10.2 94 110.0 437 01-03-06 M. Griffin's House 4.0 BPG 99.1 13.0 90 110.0 Patio Finish Grade 438 01-04-06 West corner of Griffins House PG 99.5 14.7 91 110.0 439 01-04-06 West corner of Griffins House PG 101.0 15.7 92 110.0 Clubhouse Area 440 01-13-06 Club House 3.0 BPG 109.1 6.9 99 114.0 441 01-13-06 Club House 3.0 BPG 106.7 9.5 97 114.0 442 01-13-06 Club House 3.0 BPG 108.6 9.9 99 114.0 443 01-13-06 Club House 3.0 BPG 105.6 8.1 96 114.0 House Pads 444 01-17-06 Lot 73 PG 109.1 10.3 99 110.0 445 01-17-06 Lot 74 PG 105.2 8.7 96 110.0 446 01-17-06 Lot 75 PG 106.6 7.5 97 110.0 447 01-17-06 Lot 97 PG 101.6 8.9 93 110.0 448 01-17-06 Lot 98 PG 101.7 5.3 93 110.0 449 01-17-06 Lot 99 PG 106.9 6.2 97 110.0 450 01-17-06 Lot 100 PG 104.5 7.4 95 110.0 451 01-17-06 Lot 101 PG 100.7 8.7 92 110.0 452 01-18-06 Lot 161 PG 104.8 9.6 95 114.0 453 01-I8-06 Lot 162 PG' 106.8 10.2 97 114.0 454 01-18-06 Lot 163 PG 104.6 9.5 95 114.0 455 01-18-06 Lot 164 PG 107.2 11.1 97 114.0 456 01-18-06 Lot 165 PG 108.9 10.2 99 114.0 457 01-18-06 Lot 166 PG 108.5 9.6 99 114.0 Club House Area 458 01-24-06 Club House PG 1.08.9 10.2 99 114.0 459 01-24-06 Club House PG 107.2 8.5 99 114.0 460 01-24-06 Club House PG 108.7 8.5 99 114.0 DATE: June 29, 2006 .chwfdo.. F....:.,,...:.... PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California Test No. Date Tested Location Densitv TEST RESULTS PROJECT NO: 522-4402 REPORT NO: 06-06-667 Elevation Dry Density % Moisture Relative Maximum In Place In Place Comnactior .Q/nddon F»ninnnaissn Club House Area 461 01-24-06 Club House PG 108.4 9.2 98 114.0 462 01-24-06 Club House PG 109.1 10.2 99 114.0 463 01-24-06 Club House PG 108.7 9.4 99 114.0 464 01-24-06 Club House PG 109.1 10.1 99 114.0 465 01-24-06 Club House PG 107.9 11.4 98 114.0 466 01-24-06 Club House PG 106.8 10.2 97 114.0 467 01-24-06 Club House PG 108.8 9.2 99 114.0 468 01-24-06 Club House PG 107.9 11.2 98 114.0 469 01-24-06 Club House PG 108.9 10.4 99 114.0 Building Pads 470 03-20-06 Lot 75 4.0 BPG 108.0 6.7 98 114.0 471 03-20-06 Lot 75 2.0 BPG 108.1 8.3 98 114.0 472 03-20-06 Lot 77 4.0 BPG 109.1 5.6 99 114.0 473 03-20-06 Lot 77 2.0 BPG 107.7 8.3 98 114.0 474 03-20-06 Lot 79 4.0 BPG 107.3 7.4 97 114.0 475 03-20-06 Lot 79 2.0 BPG 107.3 6.9 97 114.0 476 03-20-06 Lot 81 4.0 BPG 106.3 6.7 96 114.0 477 03-20-06 Lot 81 2.0 BPG 108.1 7.4 98 114.0 478 03-31-06 Lot 186 PG 109.1 5.2 99 114.0 479 03-31-06 Lot 195 PG 108.7 6.3 99 114.0 480 03-31-06 Lot 196 PG 107.8 5.9 98 114.0 481 03-31-06 Lot 197 PG 107.3 7.5 97 114.0 482 03-31-06 Lot 206 PG 109.1 6.3 99 114.0 483 03-31-06 Lot 207 PG 108.7 7.2 98 114.0 484 03-31-06 Lot 167 PG 109.0 7.1 99 114.0 485 03-31-06 Lot 168 PG I07.2 5.9 99 114.0 486 03-31-06 Lot 169 PG 108.2 6.1 98 114.0 487 03-31-06 Lot 170 PG 108.9 7.1 99 114.0 488 03-31-06 Lot 171 PG 108.9 9.4 99 114.0 489 03-31-06 Lot 172 PG 108.8 8.2 99 114.0 490 03-31-06 Lot 173 PG 108.2 6.7 98 114.0 491 03-31-06 Lot 174 PG 107.8 5.8 98 114.0 492 03-31-06 Lot 187 PG 106.5 7.2 97 114.0 493 03-31-06 Lot 185 PG 108.8 6.3 99 114.0 494 04-03-06 Lot 76 PG 108.9 6.1 99 114.0 495 04-03-06 Lot 77 PG 108.6 5.4 99 114.0 496 04-03-06 Lot 78 PG 109.2 7.2 99 114.0 497 04-03-06 1 Lot 79 PG 108.6 8.3 99 114.0 DATE: June 29, 2006 .Q/nddon F»ninnnaissn w TEST RESULTS PROJECT NAME: Griffin Ranch LOCATION: La Quinta, California PROJECT NO: 5224402 REPORT NO: 06-06-667 Test No. Date Tested Density Location Elevation Dry Density % Moisture In Place Relative In Place Maximum Compaction Building Pads 498 04-03-06 Lot 80 PG 103.3 7.7 94 110.0 499 04-03-06 Lot 81 PG 106.8 9.1 99 110.0 Wall Backfill 500 04-10-06 South East Retention SG 109.1 11.2 99 114.0 501 04-10-06 South East Retention SG 107.6 10.6 98 114.0 502 04-10-06 South East Retention SG 108.2 8.2 98 114.0 503 04-10-06 South East Retention SG 108.8 9.6 99 114.0 504 04-10-06 South East Retention SG 109.1 13.2 99 114.0 505 04-10-06 South East Retention SG 107.7 14.1 98 114.0 506 04-10-06 South East Retention SG 105.9 9.9 96 114.0 507 04-10-06 South East Retention SG 106.7 10.8 97 114.0 508 04-10-06 South East Retention SG 109.1 11.8 99 114.0 509 04-10-06 South East Retention SG I09.1 12.1 99 114.0 DATE: June 29, 2006 Sladdeir E►inineeririn CITY OF LA QUINTKSUB-CONTRACTOR LIST JOB ADDRESS PERMIT NUMBER OWNER BUILDER. This form shall be Hosted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any -changes to this list must be approved by. the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by aDDlicant. "On File" is not an acceptable response. Trade Cla sific i : / s anon Contractor ::;-:::.:.:::.:: :: :....:.: . : . :;;::»;:><::::;:;:>:<. Stat '::Co ::....; :.:..: a ntracto► s L�certse : •= Workers Compensation insurance " City Business Lieense> Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C-12) ; -: CONCRETE (C-8) /?C id Ct C of �o i id . C:s•11i SS.9t4Urti. •ATNC I- C. g $Q Z ( O� '123 5 3 q ! Z-31- l3 �Q -3�`-t fi �e�t RNs_ S 7G foo 00 81313 ( - t-=2ot�! (-18 33 I 5 A-1 3 31- �1 1-31-14 FRAMING :(C-5) � 0rockka%n i Io 2 (.. lo- iq IaT% C0 �U ^� u l `� 4 �: ( . -31-11 STRUCT.:-S7EEL- (G-51) MASONRY (C-29) PLUMBING'(C-36)" T tClnaa Q0 - I- -I- LATH; PLASTER (C-35) n � /l �a> (\iC � 15 n �j 35H2 - �`f S kc i ;1 �iwp. �61 �� -1 q �°)o _ 6 - �_ 3 p . DRYWALL (C -9):.:..:n vri V1uCios1 l _q (,2 1 D-1� Sl'� I�' p "l R-30-6 ` �j E`1 _31 _I . HVAC (C -20):.::::"".:a 4f"f�NDi�(t2 - ZD q 7g �� t ( 30 S ' Ac`n Ug i mew f6,q 90 (0q-3 S- t3 5 2- 1q ELECTRICAL. (C=10)' C9 of 0 AQO0ING-(C39)'::::>`:"' 13A2Vi ,n ' SHEET.METAL (C-43) ` �jolZ.O�� f' - r-( 23'2.23 FLOORING GLAZING 10:17i":' .::. :.>•:. RoAryl 91fle 1f(l}.2 )$S :..: • .:::: INSULATIOfV'(C-2) : ;: 3C:1 C v/15 vJJc. 1.3-1 ,� �^� G ,"1.5 ��� I l- 4) 5 17 C;aM �Y)� �,j `11011 651 -VA �j , �3i � � -?j�- SEWAGE DISP-(G-42) E nj lG �. SNC. J� 1 PAINTING (C=33) • : CERAfiAIC TILE (C-54) CAt31NETS (C-6) FENCING (C713) - IANDSLAPING (C'-27.).. ` +1 A n� rr_s�► . C1 / n Jesse White - Secretary of State 't ( NUMBER ISSUED EXPIRES C552-2215-4937 09-22-06 .� �j ELIZABETHANN;CANNING I 27930 W RIVER TRAIL,�`Y`� BARRINGTON IL -60010 : Birthdate 111=27543 Female 5'06',`+135 lbs;,;BLUE Eyes Restrictigns.f ti.. TYPb' 'd'lass Electronically Filed by Mark Gallant, CEPE and Authenticated at CalCERTS.com - 10/15/2013 Electronically Signed at CalCERTS.com by D Kirk McKinley (The McKinley Associates, Inc.) 10/15/2013 h' PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Pro;,2ct Name Canning Casita Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11011512013 Date Project Address La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 517 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-13 734 New Door Opaque Door None 24 New Roof Wood Framed Attic R-30 517 Radiant Barrier New Slab Unheated Slab -on -Grade None 517 Perim = 96' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (S) 36.0 0.320 0.30 none none Bug Screen New Left (M ��� _ 36.0 _ 0.320..- X0.30--. none-, ---- xnone t,- Bug Screen. , New Rear (N)I' Y 20.0 0.320 1 0.30 none- f none Bug Screen New Right (E) 12.0 0.320 0.30 none I 'none Screen New 1!1^ -LAE11 BUILDING t SAFEi I. APPROVED HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.82 No Pipe Insulation New IIIIIII IIID III VIII IE IIII 78 EnergyPro 5.1 Ty EnergySoft User Number. • 2875 RunCode: 2013-10-15708:32:09 ID: Pae 1 of 5 Reg: 213-NO07813OA-000000000-0000 Registration Date/Time: 2013/10/15 11:38:01 HERS Provider: CalCERTS, Inc E Electronically Filed by Mark Gallant, CEPE and Authenticated at Ca10ERTS.com - 10/15/2013 Electronically Signed at CalCERTS.com by D Kirk McKinley (The McKinley Associates, Inc.) 10/15/2013 PERFORMANCE CERTIFICATE: Residential . (Part 2 of 5) CF -1 R Projpct Name Canning Casita Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11011512013 SPECIAL FEATURES INSPECTION CHECKLIST ' The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED ,VERIFICATION Items in this section require field testing and/or verification by a certified HERS RateAhe'inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Rheem RGPN05NAUER/1.5T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnergySoft User Number: 2875 RunCode: 2013-10-15708:32:09 ID: Page 2 of 5 Reg: 213-NO07813OA-000000000-0000 Registration Date/Time: 2013/10/15 11:38:01 HERS Provider: Ca10ERTS, Inc Electronically Filed by Mark Gallant, CEPE and Authenticated at Ca10ERTS.com - 10/15/2013 Electronically Signed at CalCERTS.com by D Kirk McKinley (The MCKin1Pv ARAnriatPc. Tnr i 1n/1s/7n11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Proigct Name Building Type 0 Single Family ❑ Addition Alone Date Canning Casita 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 10/15/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.05 4.82 -0.77 Space Cooling 81.64 91.24 -9.60 Fans 16.50 23.18 -6.68 Domestic Hot Water 43.39 23.19 20.19 Pumps 0.00 0.00 0.00 Totals 145.57 142.42 3.14 Percent Better Than Standard: 2.2% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 257 36 Fuel Available at Site: Natural Gas (K9 174 36 Raised Floor Area: 0 (N) 257 20 Slab on Grade Area: 517 (E) 174 12 Average Ceiling Height: 9.0 Roof 517 0 Fenestration Average U -Factor: 0.32 TOTAL: 104 Average SHGC: 0.30 Fenestration/CFA Ratio: 20.1% REMARKS THE INSTALLING CONTRACTORS ARE RESPONSIBLE FOR THE QUANTITYAND SIZING OF HEATING, COOLING AND DHW EQUIPMENT, DUCT SIZING AND EQUIPMENT SELECTION. (§150(h),CEC Blueprint #60) ell y r _ JJJJJJ■■■/// / / '.C� 40 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Gallant Energy Consulting Company 10/15/2013 Address 508 W Mission Ave Ste 201 Name Mark Gallant, CEPE City/State/ZipCity/State/Zip Escondido, CA 92025 Phone 760-743-5408 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company McKinley Assoc Inc e �i 10 -jr - Address 1818 First Ave., Ste. 200 Name 1%FFf/� City/State/Zip San Diego, CA 92101 Phone 619 238 1134 Signed License # Date EnemvPro 5.1 by EnemySoft User Number. • 2875 RunCode: 2013-10-15708:32:09 ID: Page 3 of 5 Reg: 213-NO07813OA-000000000-0000 Registration Date/Time: 2013/10/15 11:38:01 HERS Provider: CalCERTS, Inc Electronically Filed by Mark Gallant, CEPE and Authenticated at CalCERTS.com - 10/15/2013 Electronically Signed at CalCERTS.com by D Kirk McKinlev (The McKinlev Associates. Inc.) 10/15/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Projgct Name Canning Casita Building Type ® Single Family 1 ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 10/15/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Wall 197 0.102 R-13 180 90 New 4.3.1-A3 Casita Door 24 0.500 None 180 90 New 4.5.1-A4 Casita Wall 138 0.102 R-13 270 90 New 4.3.1 A3 Casita Wall 2371 0.102 R-13 0 90 1 New 4.3.1-A3 Casita Wall 162 0.102 R-13 1 90 90 New 4.3.1-A3 Casita Roof 517 0.031 R-30 180 18 New 4.2.1-A20 . Casita Slab 104 0.730 None 0 180 New 4.4.7 -Al Casita Slab 413 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 36.0 0.320 NFRC 0.30 NFRC 180 New NonMetal LowE2 Casita 2 Window 36.0 0.320 NFRC 0.30 NFRC 270 New NonMetal LowE2 Casita 3 Window 20.0 0.320 NFRC 0.30 NFRC 0 New NonMetal LowE2 Casita 4 Window 12.0 0.320 NFRC 0.30 NFRC 90 New NonMetal LowE2 Casita Zr (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC Hclt Wd Overhang Len H t LExt RExt Left Fin Right Fin Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. • 2875 RunCode: 2013-10-15T08:32:09 ID: Pa e 4 of 5 Reg: 213-NO07813OA-000000000-0000 Registration Date/Time: 2013/10/15 11:38:01 HERS Provider: CalCERTS, Inc Electronically Filed by Mark Gallant, CEPE and Authenticated at CalCERTS.com - 10/15/2013 Electronically Signed at CalCERTS.com by D Kirk McKinley (The McKinley Associates, Inc.) 10/15/2013 CERTIFICATE OF COMPLIANCE: Residential (Part .5 of 5) CF -1 R Project Name Canning Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/15/201 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existino Altered Removed Volume Year Built HVAC System Casita 517 4,653 Totals 5171 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION •. System Name Heating r .. �- -_'Duct ? V Ducts' -"C Coolin Duct Location R -Value Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 New ❑ 0 WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Rinnai R94LS 1 Instant Gas No Pipe Insulation 199,000 0 0.82 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 i� a — System Name Pipe Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 13 103 13 13 EnergyPro 5.1 by EnergySoft User Number: 2875 RunCode: 2013-10-15708:32:09 ID: Pa e 5 of 5 Reg: 213-NO07813OA-000000000-0000 Registration Date/Time: 2013/10/15 11:38:01 HERS Provider: Ca10ERTS, Inc GRIFFIN RANCH HOMEOWNERS ASSOCIATION "oJessiona[[y managed by NPersonalized Property Management October 13, 2013 MR. TERRY CANNING 27930 W. RIVER TRAIL BARRINGTON, ILL. 60010 68-950 Adelina, Road Cathedral City, CA 92234 Phone: {760) 325.9500 Fax: (760) 325300 Re: Architectural application approval for addition of casita; 54-200 Affirmed Court, GrMn Ranch Homeowners Association. Dear Mr. Canning: - The Architectural Committee has reviewed your request for the addition of a casita to be built on the property at your home, per the application, and plans submitted. We appreciate your adhering to the Architectural Guidelines and procedures as part of this exciting project with your submission of all of the proper forms, application and such detailed plans. After review of the materials submitted, the Architectural Committee has approved your proposed installation as submitted. With receipt of this letter, you may,move forward with your project in conjunction with the specifications set forth and approved. A reminder that any fees or City permits necessary would be the responsibility of the homeowner to obtain in advance of this undertaking. Again, we appreciate the time and proper course of action you have taken in the planning of this exciting project and look forward to sharing in this outcome and finished product with you, as your neighbors. We wish you the best in your endeavor! FOR THE GRIFFIN RANCH HOMEOWNERS ASSOCU TION BOARD OF DIRECTORS Sincerely, Michael W. Livingston CCAM Community Manager cc: Board of Directors Tim Jac ilewski, consulting Architect Ale. r ® Won. a i r P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 7$-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 IIIIIIIIIIIIIIIIIIIIIIIII 79 IE BUILDING &'SAFETY DEPARTMENT (760) 777-7012 _-FAX (760) 777-7011 PROPERTY OWNER'S PACKAGE Disclosures & Forms for Owner -Builders Applying for Construction Permits I1WORTANTt NOTICE TO PROPERTY OWNER Dear Property Owner , An. application for -a building permit has been submitted in your name- listing - yourself as -the builder of the .property Improvements specified at $ -,:9 .00 l/NeCi f' , �A Q Lf/i✓T3�/ (A We are providing you with an Owner -Builder Acknowledgment and Information-Venfication Form to make you aware of your respowrb.ilities and possible risk you may incur by having thispermit issued m your name as the f Owner -Builder. We will not issue a buildinrg.permit until you -have read, initialed your understanding of each`provision, . signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this -notice unless you, the property owner, obtain the prior approval of the permitting authority. OV R'S ACRRMADOW-U ?VT ANDD-VERMCATION OF I1 O1 AMN' DIRE ONS: Read and initial each. statement below to signify you understand or verify this information: 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" wilding permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance -coverage for injuries to workers on mY properh' y K2. I understand building permits are not required to be signed by property owners unless they are responsible for the onstruction and are not hiring a licensed Contractor to assume this responsibility.. 3. I understand as an "Owner -Builder" I am the responsible party of record on the,per *' .I understand That I may protect of from potential financial risk b hiring a licensed Contractor and having the permit filed in his or her name instead of m Y g g Pe Y own. K4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on ermits and contracts. Kmyvf5 I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value construction is at least five hundred dollars $500 including labor and materials I may be considered an ,employee, ( ). g Y under state and federal law. 6" I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to -serious financial risk. Ktruct7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential ures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. s 8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable, for any financial or personal. injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. 9. I understand I may obtain more information regarding my obligations as an "employer" from the Iutcml Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.csib.ca.gov for more information about licensed contractors. /� 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the }' p!arty legallyand financially responsible . for proposedconstruction activity at the following address: 5 y-2oo PA ed 1. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I ave provided on this form: Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license,. the Contractors' State License Board may be unable to finaswial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property; you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying wfiedw or not those Contractors are properly licensed and the status of -their workers' compensation insurance coverage. Before x building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing, Note: A copy of tkc s progeny owner's driver's J&wtsef farm notadC"A" or other verifuadon acceptable to the agency is required to be presented when the permit is issued to Verify the property owner's signature. /7 Signature of property Date: //- a / —/3 Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execvtion of which I understandis my personal responsibility, I hereby authorize -the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project- Scope rojectScope of Construction Project (or Description of Work): �f�s. / T7,2 Project Location or Address: V- 2_&20 /_/q ( g1,4J1_W0 CO_ _ Name of /luthorized Agent: 1� l Cf llwo 64-" L C S Address of Authorized Agent: go 7 I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is requir e presented when e�ermit is issued to verify the property owner's signature. Property Owner's Signattrrr,%jZ��/L%2J ( �a�6­0� , Date: //- a/-/3 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Griff ni R na ch Owner's Name: Elizabeth & Terrence Canning Project Address: 54-200 Affirmed Ct., LaQuinta Project Description: Casita APN: 767-780-077 Tract #: Type of Development: Residential XX! Total Square Feet of Building Area Commercial 517 Date: March 11, 2014 Phone No. 847-922-8128 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: March 11, 2014 Signature:�,�„� SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. Amount per Sq.Ft. Amount Collected 517 $3.20 $1654.40 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: 1 LZ. 1. v NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/certificate of compliance fbinl updated 3-2007 11/2010