Loading...
06-3325 (SFD)IE P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 34 c&ht 4 4a " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 06-00003325 54320 AFFIRMED CT 767-320-999-303 -32879 - DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 213713 Owner: MCCOMIC GRIFFIN LLC 7979 IVANHOE AVE #550 DETACHED LA JOLLA, CA 92037 rchjtect or Engineer: -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of taBne.ss and Profess' nals Code, and my License is in full force and effect. License C ss: B LicenseNo.: 701039 WNER-BUILDER DECLARATION Ihereby affirm under penalty ofat I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, nd Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure isnot intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Contractor: TRANS WEST HOUSING, INC. 9968 HIBERT STREET, STE 4102 SAN DIEGO, CA 92131 (858)653-3003 Lic. No.: 701039 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/04/07 --------------- - - - WORKER'S COMPENSATION DECLARATION I rr FEB &---.'-7 11M CITY OF LA Biu I TA I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1648813-2006 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become su ject to the workers' compensation laws of California, and agree that, if I s ould become subje to the workers' compensation provisions of Section /37700 of the Labor C shall fort comply with those provisions. plicant: WARNING: FAILURE TO SEC RE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO RIMI AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADD N TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above informatio is correct. I agree to comply with all city and county ordinances an state laws relating to ilding construction, nd hereby authorize representatives of this my enter upo he above-mentioned prop for insp rposes. /�e, 'nature (Applicant or Agent): Application Number Permit . . Additional desc . . Permit Fee . . . . Issue Date. Expiration Date . . . . . 06-00.003325 BUILDING PERMIT 1038.50 Plan Check Fee . . 675.03 Valuation . . . . 213713 7/03/07 Qty Unit Charge Per Extension BASE FEE 639.50 114.00 3.5000 THOU BLDG 100,001-500,000 399.00 ------------------------------------------------------------------------------ Permit . . . MECHANICAL Additional desc'. . Permit Fee . . . . 90.00 Issue Date . . . . Expiration Date . . 7/03/07 Plan Check Fee . . 22.50 Valuation . . . . 0 Qty Unit Charge Per, Extension BASE FEE 15 '.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 145.86 Plan Check Fee 36.47 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/03/07 Qty Unit Charge Per Extension BASE FEE 15.00 3373.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 118.06 640.00 ----------------7----------------------------------------7------------------ .0200 ELEC GARAGE OR NON-RESIDENTIAL 12.80 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 166.50 Plan Check Fee 41.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/03/07 .Qty Unit Charge Per Extension BASE FEE 15.00 16.00 6.0000 EA PLB FIXTURE 96.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 LQPERMIT LQPEnI IT Application Number . . . . . 06-00003325 Permit . . . . . . PLUMBING Qty Unit Charge Per BASE FEE Extension 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 8.00 .7500 EA PLB GAS PIPE >=5 6.00 1.00 ---------------------------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT DIF LIBRARIES - RES Additional desc . . Permit Fee . . . . 15.00 Issue Date . . . . Expiration Date . . 7/03/07 Plan Check Fee . . .00 Valuation . . . . 0 Qty Unit C_.arge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 303, PLAN 3DR, 3373 SF. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY CODES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 34.28 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 67.50 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 21.37 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Permit Fee Total 1455.86 Plan Check Total 775.63 Other Fee Total 3819.15 Grand Total 6050.64 Paid Credited Due .00 .00 1455.86 .00 .00 775.63 .00 .00 3819.15 .00 .00 6050.64 a CITY OF LA Q -k' w4 BUILDING & SAFETY DEPAR-MENT °b OF° 777-7012 u INSPECTION REQUE ', t NE LCC j- ®? 777-7153 t.L i i Owner GRIFFIN RANCH, LLC I i Contractor TRANS WEST HOUSING Permit Number 06-3325 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 54-320 AFFIRMED COURT SFD — LOT 303, PLAN 3DR, 3373 SF. 'PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH TYPE OF INSPECTION DATE INSP. TEMPORARY POWER ` SETBACKS .(7 U/G PLUMBING / WASTE -7- % U/G ELECTRICAL /GROUNDING FOOTINGS / STEEL - o . CONCRETE SLAB 07(,-. 01 DO NOT POUR CONCRETE UNTIL ABOVE SIGNED ROOF NAIL./ PRE -ROOF to _ _ 1 r -1Y TO WRAP _4;VAING COMBINATION ROUGH ELECTRIC ROUGH PLUMBING p ROUGH MECHANICAL INSOLATION a COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP. BD. DRYWALL G - rl, - 6 r� A! EXTERIOR LATH • IZ ' b'1 J GAS TEST `'l - q • 01 jJc SEPTIC ABANDONMENT SEWER CONNECTION SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS { U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER (ALARMS/ BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER - p -t ELECTRICAL 'MBING ,;HANICAL PUBLIC WORKS DEPARTMENT %Z.- - O 7 COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING 09-25-07;02:15PM;GATEWAY INS. f ;951-303-1576 # 2/ 13 6-1-30-5 THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN COMFORMANCE WITH THE CURRENT ENERGY REGULATIONS, CALIFORNIA ADMINISTRATIVE CODE, TITLE 24, STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT: SITE ADDRESS: 54320 AFFIRMED COURT, LA QUINTA CA. EXTERIOR WALLS -- 2 X 4 MANUFACTURER -CERTAINTEED THICKNESS/TYPE-6.25" FIBERGLASS R/VALUI; - R19 EXTERIOR WALLS -2 X 6 MANUFACTURER- CERTAINTEED THICKNESS/TYPE-6.2511 FIBERGLASS R/VALUE - R19 CEILINGS BLOW: MANUFACTURER - CERTAINTEED TT-TTCKNESS/TYPE -14.75" FIBERGLASS R/VALUE - R33 GENERAL CONTRACTOR: TRANSWEST LICENSE # INSULATION CONTRACTOR: GATEWAY INSULATION, INC. LICENSE # 797001 BY; fm TITLE: OPERATIONS MGR, DATE: 9/25/2007 BUTCH INGRANT OPERATIONS MANAGER. 0 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC- TESTING (P: Builder Name rod ct Address • �RN as t.s Builder Contacts 'Lem Telephone Plan Number Number HERS Rater--,A� `� . � t ��� ��Z-i Z• [ Certifying 1 of 8) CF -4R I1 - 1A — Climate Zone �� Date Sample House Number . 1a -r Fi' — LO A cM *-_1 Street Address: City/State/Zip: Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓ ❑ Tested ✓ �DApproved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked v/ on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building. The HERS rater must not release the CF -4R until a properly completed and signed CF -6R has been received for the sample and tested buildings. The installer has provided a copy of CF -6R (Installation Certificate). New Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts). New systems where cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks'at duct connections. ✓ INIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDiT Procedures for field verification and diagnostic testing of air distribution systems are available in RA CM, Appendix RC4.3. UuGl VidglivZ Lu.5v a --t, ........-....- NEW CONSTRUCTION:. ::: . Measured_ ., Duct Pressurization Test Results (CFM @ 25 Pa) Values � ;;, la " 1 Enter Tested Leakage Flow in CFM: Fan Flow: Calculated (Nominal: ✓ ❑ Cooling ✓ ❑ Heating) or 0' ✓ ✓ 2 Enter Total Fan Flow in CFM: Enter 3 Pass if Leakage Percentage <_ 6% [ 100 x L_(Line # 1) / (Line # 2)]] Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out<•• `� Enter Tested akage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to _rK,:Y,t „_ 4 Duct System A on and/or Equipment Change -Out. y �' Enter Tested Leakage CFM: Final Test of New Duct System or Altered Duct System for Duct System Alteration an ui ment ('hange-Out -- Enter Reduction in Leakage for Alt e tict System [(Line # 4) Minus (L' )] 6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside pplicable) `/ Entire New Duct System - Pass if Leak P ntage :5 ❑ Pass ❑Fail 8 100 x Line # 5 / TEST OR VERIFICATION STAND S: or Alte uct System a r HVAC Equipment Change -Out Use one of the following four Test or erificatio andards for compliance: - ❑ Pass ❑ Fail Pass -if Leakage Percentage <_ 15% L (Line # 5) / (Line 9 if Leakage to Outsid entage <_ 10% [100 x L_(Line # 7) / (Line # ❑ Pass ❑ Fail ❑ pass ❑ Fail 10Pass Pass if Leakage ction Percentage >: 60% [100 x_(Line # 6) / (Line # 4)1] 11. and Veri on b Smoke Test and Visual Ins ection of all Accessible Leaks and Verification by Smoke Test and Visual Inspection �M. ❑ Fail •12 Pass ealing Pass if One of Lines # 9 through # 12 pass [I Pass Fail d—a inns Residential Compliance Norms `