Loading...
04-8087 (SFD)34 E TAMPICO CALIFORNIA 92253 BUILDING PERMIT Property Address . . . APN: Application description Property Zoning . . . . Application valuation . Owner SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE AZ 85258 IIIIIII VIII III VIII IIII 56 IE BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 04-00008087 Date 1/31/05 60256 ALOE CIR 764-270-999-177 -300233- DWELLING - SINGLE FAMILY DETACHED MEDIUM HIGH DENSITY RES 149793 Contractor SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA CA 92253 (760) 777-6005 WCC: NTL UNION INS WC: 6436568 08/01/05 CSLB: 672285 06/30/05 CCC: B -------------------------- Structure Information ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG 576.00 PATIO SQ FTG' 177.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 1685.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 814.50 Plan Check Pee 529.43 Issue Date . . . . Valuation . . . . 149793 Qty Unit Charge Per Extension BASE FEE 639.50 50.00 3.5000 THOU BLDG 100,001-500,000 175.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 93.00 Plan Check Fee 23.25 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: I hereby affirm and Code, nd my Lice ns.0a Cla11sss -Bate �9 -1 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 or Engineer's Address: O.: V U BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION y of perjury that I am licensed under provisi s or (conlme th Section 7000) of Division 3 of the Business and Professionals full force and effect./� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work r which this permit is issued. "ted. nd will aintain work ' compensation insurance, as re uired y S on 700 o e Labor Code, for the performance of the work for which this permit is y olkers' comp sation ins ce cam a9� o p nn r n Amer I �•r-- icy Number _ I certify that, in the performance o the work for whi this permit is issued. I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that i I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those pr 'si / at nt r WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each a es to, and shall, defend, indemnity and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work ing performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is co . agree to comply with all city and county ordinances and state laws relating to building constructio , and hereby=authonze ntativesof thiscounty r upon a e -me oned property for inspection purposes. plicant or Agent). 4 Page 2 Application Number . .. . . . 04-00008087 Date 1/31/05 Qty Unit Charge Per Extension 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 85.50 Plan Check Fee 3.77 Issue Date . . . . Valuation . . . . 0 Qty Unit.Charge Per Extension BASE FEE 15.00 1685.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 58.98 576.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.52 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 128.25 Plan Check Fee 32.06 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 .1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 ---------------------------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Permit . . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension --------------------------------------=------------------------- BASE FEE 15.00 Special Notes and Comments - ----------- SFD - LOT 177, 1685 SF PLAN 4520B.BAY @ MBR -23 SF, 88 SF GARAGE EXT. PERMIT -DOES NOT INCLUDE BLOCK WALL, POOL OR DRIVEWAY APPROACH. ---------------------------------------------------------------------------- Other Fees . . . . . ART IN PUBLIC PLACES -RES .00 Page 3 Application Number . . . . . 04-00008087 Date 1/31/05 --------------------- ------------------------------------------------------ Other Fees . . . . . . . . . DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 52.94 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 14.97 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 1136.25 .00 588.51 .00 2472.91 .00 4197.67 .00 Credited Due .00 1136.25 .00 588.51 .00 2472.91 .00 4197.67 PREPARED 3/15/11, 12:43:59 INSPECTION HISTORY REPORT PAGE 1 PROGRAM BP521L 0/00/00 THRU 0/00/00 CITY OF LA QUINTA ------------------------------------------------------------------------------------------------------------------------------------ APPLICATION PROPERTY ADDRESS APN Alternate ID ' STRUCTR ------------------------------------------------------------------------------------------------------------------------------------ PERMIT INSPECTION RESULT DATE/STATUS INSPECTOR 04 00008087 60256 ALOE CIR 764-270-999-177 -300233- 000 000 B001 00 BUILDING PERMIT 120 0001 FOOTINGS 3/02/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 125 0001 SLAB 3/02/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 135 0001 ROOF NAIL 3/30/05 APPROVED ST 000 000 B001 00 BUILDING PERMIT 140 0001 OKAY TO WRAP 4/11/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 145 0001 FRAMING 4/14/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 150 0001 INSULATION 4/15/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 155 0001 LATH 4/21/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 160' 0001 DRYWALL NAIL 4/21/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 900 0001 COMMUNITY DEVELOPMENT FIN 6/14/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 910 0001 PUBLIC WORKS FINAL 6/14/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT - 199 0001 FINAL 6/14/05 APPROVED GH 000 000 E01 00 ELEC-NEW RESIDENTIAL 310 0001 ROUGH ELECTRICAL 4/14/05 APPROVED GH 000 000 E01 00 ELEC-NEW RESIDENTIAL 315 0001 TEMP USE OF PERMANENT POW 5/20/05 APPROVED GH 000 000 E01 00 ELEC-NEW RESIDENTIAL 399 0001 ELECTRICAL FINAL 6/14/05 APPROVED GH 000 000 GP 00 GRADING PERMIT 197 0001 GRADING FINAL 6/14/05 APPROVED GH 000 000 MO1 00 MECHANICAL 405 0001 ROUGH MECHANICAL 4/14/05 APPROVED GH 000 000 MO1 00 MECHANICAL 499 0001 MECHANICAL FINAL 6/14/05 APPROVED GH 000 000 PO1 00 PLUMBING - 210 0001 SEWER CONNECTION 2/24/05 APPROVED GH 000 000 PO1 00 PLUMBING 200 0001 UNDERGROUND PLUMBING 2/24/05 APPROVED - GH 000 000 PO1 00 PLUMBING 230 0001 ROUGH PLUMBING 4/14/05 APPROVED GH 000 000 PO1 00 PLUMBING 245 0001 SHOWER PAN 4/14/05 APPROVED GH 000 000 PO1 00 PLUMBING - 235 0001 GAS LINE / GAS TEST 5/12/05 APPROVED GH ' 000'000 PO1 00 PLUMBING 299 0001 PLUMBING FINAL 6/14/05 APPROVED GH YG :O/.<:aavc+.•/.'J. :nN.rvr/.:Y�i/9.• y.VroACY/�16w This is to certify that insulation has been installed In conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 60-331 ALOE CIRCLE, LOT 3174, PHASE 9A, LA QUIINTA, CA CEILINGS: TYPE: BLOW MAUNFACTURER: Certainteed THICKNESS: R-38 WALLS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-13 GENERAL CONTRACTOR: SHEA HOMES - LICENSE # BY: TITLE: PARAGON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 s BY: TITLE: ACCOUNT REPRESENTIVE DATE: .r• . /..^.�:'. .: n!.l'.4+.i.: :>:'.://.1,:%i:. ri.ii:):/�.-:'�i///•1Y:'h...:.i�:^gni.'1'/:i•!Y'1/.'N..://:/%/•si.�:.ri:rY'<Y/./.YY/':i.:filXfh�%1."/r�^J.✓."Y✓•t.Y•%l.%l:aYia/Jw%:.'ri:..:.:::'y/:N'f•^.:'.Y.:%X.'G'l.'.fh•r..iv:^Y..�J}�:•.: �.:... .. .. .. t • . .. _. /. n._....nr+..J+I•.r.,+•J'�:///i%f///yiY/Y/.'!//1.'J!Jl•%�/r%J///r%./iN:///.!/J/l.'!/J/nI/✓/✓Y!///!/%/J/Y/✓/�Y,i/�•/r//%A://J/l/Y'6/%%i,Ni/.er//'l.'/. N..+.�%1/f.•. •r: •..•"!.: • INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, Califomia Administrative Code, Title 24, State of California, in the building located at 60-271 ALOE CIRCLE, "TOT PHASE 9A, LA QUINTA, CA CEILINGS: TYPE: BLOW MAUNFACTURER: Certainteed THICKNESS: R-38 WALLS: TYPE: BLOW MAUNFACTURER: Certainteed THICKNESS: R-11 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY; TITLE: PARAGON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 gY; TITLE: ACCOUNT REPRESENTIVE DATE: IIIIIIIIIIIIIIIIIIIIIIIII 57 ' ..,.,.... +..... � .�:� w..._... ... ._. .... Y..'L+m:Y.tlh-:lY.�//� 1:1/arA.-':lAC/•w' rt//•MeiLNM.6..!/fAH'v.QrStEIJ.:r�NY'J1:J1:W+:�.d.%-0'-r/•'.C'.^J'.a�•• .— —.. IE b0 39dd QINHOS N09VNVd P0639PE09L L0:60 5002;/E0/90 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of ' - CF -4R TRILOGY @ LA QUINTA- PH- 9A (Partial) Project Title 60271 Aloe Circle, La Quinta CA 92253 ProjectJ 0e inor 760-535-2192 Buitde>ti c&t Henson (CCN #CC2004076)760-250-7022 Telephone - 760 250-7022 HERS Rater Ce ying Signature Firm: BCI Testing Street Address: PO Box 50575 Copies to: Builder, HERS Provider 6-15-05 Date SHEA HOMES Builder Name Plan 4520 Bay (a Mbr Plan Number N/A Telephone Sample -Group Number 6-8-05 172 {ph 9A)� Date Sample House Number HERS Provider: CALCERTS City/state/Zip: Phoenix, AZ 85076 HERS RATER COMPLIANCE STATEMENT The house was: q4ested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply, with the diagnostic tested compliance requirements as checked on this form. R( The installer has provided a copy of CF -6R (Installation Certificate. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. JAI MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM .5(10 If fan flow is calculated as 400cfin/ton x number of tons enter calculated value here 1600 If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = S �� 2 ° Check Box for Pass or Fail (Pass=6% or less) ❑ J9. THERMOSTATIC EXPANSION VALVE (TXV) 14 Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection Yes is a pass ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1 ❑ Yes ❑ No ' ACCA Manual'D Design requirements have been met (rater has verified that actual installation matches values in CF -1R and design on plan. 2• ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. Measured Fan Flow = Yes for both 1 and 2 is a Pass Pass Fail M- . ❑ Pass Fail ❑ ❑ Pass Fail Compliance Forms August 2001 A-16 <. JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 P nECTI ONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS 1W COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 5/10105 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 9A - Lot# -3172 -Slab on Grade 3-11-05 Concrete 273-461 Casita - Required psi: 4000 9289 7 3420 9290 28 4820 9291 28f8k CERTIFIED: l V�Z � JCM Inspections supplies the tervice of compression strength test results only. Per ASTMC39 • • Page 1 of 1