Loading...
05-4672 (SOTB)79907 Amora Dr 05-4672 ' IIIIIIIIIIIIIII IIIII 50 IE P.O. BOX 1504 l 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (V-44 4 4 Q" Application Number.405 =00004672 . Property Address: 79907 AMORA DR APN: 609-380-999-67 -293234- Application description: STRUCTURES OTHER THAN BUILDINGS Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 3000 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class:se No.: /Date: Contract ✓ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMff VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/17/05 Owner: GAERTNER 79-907 AMORA DR D LA QUINTA, CA LA QUINTA, CA 92253 nrT 17 2005 Contractor: .OF HYSELL POOL COMPANY CITFYfgjISA WCC: EXEMPT yCE DE PT. WC: EXEMPT 09/30/06 CSLB: 841120 06/30/06 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier C53 Policy Number - - - - - - - - - - - - - -- I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I97M e workers' compensation provisions of Section 3700 ofhe Laborll ' h those provisi s. DaEe: I o 7-Ur Applicant: ✓✓✓WARNING: FAILURE TO SECURE WORKERS' COMPENSE NES OVER E IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned pro inspection purpose . /e: 6 ? Signature (Applicant or Agent): AIL LQPERMrr Application'Number . . . . 05-00004672 ,- Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 54.00 Plan Check Fee 35.10 Issue Date Valuation 3000 Expiration Date 4/15/06 Qty Unit Charge Per Extension BASE FEE 45.00 1.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 f 9.00 Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 16.80 Plan -Check Fee 4.20 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/15/06 Qty Unit Charge Per Extension' BASE FEE 15.00 4.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 1.80 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 18.00. Plan Check Fee 4.50 Issue Date . . . . Valuation . . . 0 Expiration Date 4/15/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments BARBEQUE ONLY. _ ---------------------------------------------------------------------------- 'Other Fees . . . . . . . . . ENERGY REVIEW FEE 3.51 Fee summary Charged Paid Credited. ----------------- Due ---------- Permit Fee Total ------------------------------ 88.80 .00 .00 88.80 Plan Check Total 43.80 .00 .00 43.80 Other Fee Total 3.51 .00 .00 3.51 Grand Total 136.11 .00 .00 136.11 LQPERMrr uH t L==;--- RvI_ I Total Permit Fees Bin # Ci Of , ty l.d Quints Building 8t Safety Division . P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # fo Project Address: q CA 0 •Owner;s Name` x A. P. Number: Address: X 7 - C Legal Description: City. ST, Zi ,Contracto- - Telephone: ^'Addre 1 City, ST -Zip: — Telephone: h one. x 3 2 _2 Project Description: X !! E, i v 'r c No( State Lic. #: X• Cit",Lic. #: Arch.. Engr., Designer: Address: - 1 sH City; ST, Zip: Telephone: hone: State' Ltc. #• ............ Construction Ctl on T e: Occupancy: Y Oc _ P cu P y Project ec t nPe (circle e on Neww e1. Add'n Alter Repair Demo ..:. Name of Contact Person: {-- • kt _ _ ~j ' Sq. Ft.: #Stories: #Units: Telephone # of Contact Person:;+` — ----,, Estimated Value of Project: X _ APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES - Plan Sets Plan Check submitted l0l y0 Item Amount Structural Calcs. Reviewed, reedy for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance . Title 24 Calcs. Plans picked up Construction SO Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical 6 Subcontactor List Called Contact Person Plumbing-k- Grant Deed Plans picked up -- S 111.1 00rZe H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review, readv for correctio i su Developer Impact Fee Planning Approval ^ C a d C to P s I A I p p Pub. Wks. Appr I • l af 'oYr tiis"IleETM t School Fees uH t L==;--- RvI_ I Total Permit Fees . .. .................... ,a-og3y V1 + dH ? '6 M>ll iL I lb 0 Al) CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION a. VAIALY Vwn -..%I. A. 744 mi -or r87 -L) oco 10 I CUSE EST %Vx-e- e-.l a eo*oY i`i"CN N "A \I 0 It El ro_ 4 j It oq9 2 grq .. \-002 _ bf.-- vg o G G G 1" C Q e O O 1" C AUG -10-2005 WED 02:59 PM TEAM HEATING & A/C FAX N0, 9516943803 P. 16 a I I II I VIII III VIII IIII 51 IE MVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 of 2 CF -6R Site Address: 79-807 Amora Drive, La Quinta, Ca 92253 Permit Number: Tract Number: 29323 Plan # 3Z Phase: 11 Lot Number: 67 Project: Esplanade Builder: Lennar Homes An Installation certificate Is required to be posted at the building site or made avalible for all appropriate inspections. Atter completion of final inspection, a copy must be provided to the Building Department (upon request) and the building owner at occupancy, per section 10-1 u5 m). MVAC SYSTEMS: Heating Equipment e ame menticle (AFUE, etc.) location Duct Load Capacit" and Model Name Systems (>= CF -1 R) (attic, eta) R -value (BTU / Hr) (BTU / H CEC eName Identicle I (SEER, etc.) ` Location I Duct I Load Number _ Systems_(>=CF-1 R) I (attic, etc.) R -value (BTU / l to undersigned, verity that a uipment listed apove is: 1) Is the ac[uai equipment Inataueu, z) equivaionr w u. 111,7 efficient then that specified in a Icngso f liance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for resi anti bu dd equipment that eats or exceeds the appropriate requirements for manufactured devices (from he A is0a egulatio or Fad where applicable. 4:b:1 if Team Heating & Air, Inc Igna re, Date installing Subcontractor o. Name OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS R DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: system of Indicate the maximum a awa Is Duct Leakage and the calculation used: 0.7 x Floor Area x (0,06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flaw 21.7 x (Heating Capacity In Thousands of output BTU per hour) x (0.06) Measured Fan Flow x .06 ME[ Pressurization Test Results 100 x Test Leakage / Fan Flow = °A Leakage Check Sox for Pass or Fail (Pass = 6% or less) Pass x Iai rX T-24 Compliance Credit was Taken for TXV TXV was Instal= x y is em ® of Indicate the maximum a owe Is Duct Leakage and the calculation used: Indicate the maximum avo1q, 0.7 x Floor Area x (0.06) for Climate Zone a through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow E= 1 X.06 D-u-ff Pressurization Test Results 100 x Test Leakage / Fan Flow - % Leakage Check Box for Pass or Fail (Pass 6% or Less) Pass ai r X 'T-24 Compliance Credit was Taken for TXV TXV was installed x PAGE 1 F2001.01 (4-02) Action Now T-24CF6-RTD&TXV macro AUG -10-2005 WED 02:59 PM TEAM HEATING & A/C FAX N0. 9516943803 P. 17 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -6R Site Address: 79-907 Amora Drive, La Quinta, Ca 92253 Permit Number: 0 Tract Number: 29323 Plan #: 3Z Phase: 11 Lot Number: 67 Project: Esplanade Builder: Lennar Homes System of Indicate the max mum a owe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0,5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow ME Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) ('7.24 Com liance Credit was Taken for TXV ys em of Indicate the maximum aliowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone B through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06) Measured Fan Flow �I DO Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fall (Pass = 6% or Less) T-24 Compliance Credit was Taken for TXV ys em = of O Indicate the maximum altoowa le Duct Leakage and the calculation used: 0.7 x Floor area x (0,06) for Climate zone a through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU er hour) x (0.06) Measured Fan Flow u Pressurization Test Results 100 x Test Leakage / Fan Flow a % Leakage Check Box for Pass or Fail (Pass = 6% or Less) r"'1T 24 Compliance Credit was Taken for TXV ` yds em of Indicate the ma mum a owe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate zone a through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow D -u -a Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass © 60/6 or Less) QT -24 Compliance Credit was Taken for TXV X .06 x .06 x .06 X.06 TXV was TXV we: TXV was TXV was I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is In conformance with the requirementslien a It. (rhe builWder shall provide the HERS provider a copy of the CF -6R signed by the builder employ su o certifying that diagnostic testing and Installation meet the requirements for Compliance credit.) p Team Heating & Air, Inc es gna ure,aInstalling u con ra or o. Name Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF6-ISTD&TXV macro M Certificate of Insulation a Your home has been insulated with John Mansville FIberalas: insulation products, which are designed m for today's safety standards and tomorrow's energy requirements. m Fiberglass is inorganic and therefore permanently noncombustible, so It does not have to be treated Ln with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated m with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will It c settle over time as may other insulation materials. m This also certifies that insulation have been professionally Installed in this home to provide_ the following thermal performance. Lennar Homes Job Name: Tapestry a Esplanade Tract: 29323 Plan# 3 Phase: Lot No: -67 Job Address: SFR -79-907 Amore Drive, La Quinta, CA Ceiling Area: R-38 blown & batt insulation Garage Ceiling: Non -Access:_ With Living Above & Sloping Areas Exterior Walls R-13 batt insulation Between Floors: Overhangs: Access Attic: With Living Above Interior Walls: Subcontractor...0 J Insulation, Inc. 72-227 Adelaid St, Thousand Palms, CA 92276 11 ti o+ - N N M g 2 Signed'. . m Mike Dickerson, General Manager -Palm Springs Division T R -means resistance to heat flow. The higher the R -value, the greater the insulating power. a Ask your builder for the fact sheet on R -values. Keep this certificate with your other valued papers. If you ever sell this home, this certificate should be passed on to the buyer. N X to Aug 12 05 03:11p BCI Testing 760-772-2950 Area Pro osed CAC>ERTS Certified Rating August, 12 2005 This Compliance rating is for the home located at: 79907Amora Drive La Quinta CA, 92253 Certificate Number: CC3-1798349492 Date Inspected: August, 10 2005 I CaICERTS Rater: William Henson CC2004076 , R F HERS Analyst: N/A Builder/Developer: Lennar Homes 1 1 Project: Tapestry @ Esplanade Plan Name: ~` Plan 3 Lot Number: 067 Specifics about this home: General Information Building Envelope Conditioned Floor Area: 2121 Square Feet Conditioned Volume: 0 Cubic Feet Orientation: N/A Number of Stories: 1 Surface Area Pro osed Actual R Value U Factor CIFront JVR alue l+actor Heating and Cooling Systems Windows Heating Equipment: Cooling Equipment: HVAC Air Distribution Duct Location: Duct Leakage Target: Duct Insulation R -Value: Air Infiltration Blower Door Target Attic 6,0 4,2 Orientation Area ProLosedd Actual SHGSH Value =TESTED 120.0 APPROVED AS PART OF SAMPLE GROUP Water Healing System Proposed ?Y I Size I Fuel I EF r Distribution Water Hearin System Actual TY SizeI Fuel EF Distribution FIRM: BCI TFsTING ADDRESS: 77.760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA, 92711 PHONE:: //760-772-2964 CERTIFYING SIGNATURE DATE Testing Results Associated to Group #8904 loaner efflcicncy n[ing adthjs home is dot—minw using Califumio llorrto Energy R;-Kng System (L-1•II:HS) rulex. Tho rating con.idws heating, cooling End water beating and assumes average weather, theratoatat sdtinga, and quantities of hot water for a typical household. Actual oncrgy use will vary according to occupant behavior. This Rating Cumplotion Summery is p—vided only atter the fea►was listed have 6vgo verified and appfovul by Iht CGI 1,S (CtttfiCd Rater shown above_ ifyuu have a tuna" or complaint mgarding this report of lho savicas used in ubtaining it, you may cA.ntact: CaICF.RTS -Customer p.12