04-6283 (SFD)60282 Angora Ct
rte.- - IIIIIIIIIIIIIIIIIIIIIIIII 72
T 0 5 2004 IGirI ICt/
,F A nUINTA
j7 ANCE Dr_
BUILDING & SAFETY DEPARTMENT
' P.O. Box 1504 ..
(760).777-7012
9 78-495 CALLE TAMPICO ' FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153
I .
BUILDING PERMIT , • -
Application Number . . . . .
Property Address:
APN:
Application description . . .
Property Zoning . . . . . . .
Application valuation .
Owner
SHEA LA QUINTA
C/O JEFF MCQUEEN
8800 N GAINEY CENTER 350
SCOTTSDALE AZ 85258
'C0410.000060- x-831 Date .9/14/04
60282 ANGORA CT
764-270-999-119 -300233-
DWELLING - SINGLE FAMILY DETACHED
MEDIUM HIGH DENSITY RES
197187
Contractor
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA CA 92253
(760) 777-6005
Structure Information
Construction Type . . . TYPE V - NON RATED
Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10
Flood Zone . . . . . . . . NON -AO FLOOD ZONE
Other struct info . . . . . CODE EDITION 2001 CBC
# BEDROOMS 4.00
FIRE SPRINKLERS NO
GARAGE SQ FTG 458.00
PATIO SQ FTG 245.00
NUMBER OF UNITS 1.00
FIRST FLOOR SQ FTG 2289.,00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT -'
Additional desc
Permit Fee . . 982.50 Plan Check Fee 638.63
Issue Date . . . . Valuation 197187
Qty, Unit Charge Per Extension
BASE FEE 639.50
98.00 3.5000 THOU BLDG 100,001-500,000 343.00
-------------------------------- -------------------------------------------
Permit . . . . . . MECHANICAL
Additional desc
Permit Fee . . . . 83.50 Plan Check'Fee,. 20.88
Issue Date . . . . Valuation 0
Qty Unit Charge Per Extension
BASE FEE 15.00
2.00 9.0000 EA MECH FURNACE <=100K 18.00
2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00
4
! f
P.O. BOX 1504 •
VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 04J -T,28-4 Date: 1O- q-0 V
Applicant: tecerr�EngilC-b\riIl:S , (j
Applicant's Mailing Address: rchitect or Engineer's Address:
f) -)t a -n -q.,
4 --tic. No.: ZC4.-lu'-W
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm unde��eeVV��Ity of perjury that I am licensed under provisions of Cha ter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
ode, and ss Licensd►iatlgfull force and effect. /
cense Class .•���� License No.
Date tb� _ � Contractor V `Cw
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Secfion 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date Owner.
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Iha`ve an II maintain w erscompensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
.J sue rkers' c pensation rance Carrie and r-1c�i�m r
Cartier �r L�.•++ —policy Number � , 17 0 e
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, �shouldecome subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.4�
Date W 'pplicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name /�
Lender's Address A
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for Whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Ouinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is corr .11 agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county enter upon the a e -mentioned property for inspection purposes.
ate 6 _�4-1
Applicant or Agent): r
r
Page
2
Application Number
.
. .
. . 04-00006283 Date
9/14/04
Qty Unit
Charge
Per
Extension
4.00
6.5000
EA
MECH VENT FAN
26.00
1.00
6.5000
EA
MECH EXHAUST HOOD
6.50
-----------------------------------------=----------------------------------
Permit . . .
.
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee .
. . .
104.28
Plan Check Fee
26.07
Issue Date
Valuation
0
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
2289.00.
.0350
ELEC NEW RES - 1 OR 2 FAMILY
80.12
458.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
9.16
--------------------------------------7-------------------------------------
Permit . . .
. . .
PLUMBING
Additional desc
. .
Permit Fee .
. . .
171.00
Plan Check Fee
42.75
Issue Date .
. . .
Valuation . . . .
0
Qty Unit
Charge
Per
Extension
-
BASE FEE
15.00
17.00.
6.0000
EA
PLB FIXTURE
102.00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
1.00
7.5000.
EA
PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00
6.00
.7500
EA
PLB GAS PIPE >=5
4.50
1.00
15.0000
EA
PLB GAS METER
15.00
-------------------------
Permit . .
-
. .
---------------------------------------------------
GRADING PERMIT
Additional desc
Permit Fee .
. . .
15.00 Plan Check -Fee
.00
Issue Date .
. . .
Valuation . . . .
0
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
--------------'------------------------------------------------'--------------
Special Notes
and Comments
SFD - LOT 119,
5320A,
2289
SF.INCLUDES
255 SF CASITA.
PERMIT
DOES
NOT INCLUDE
POOL, SPA,,' -BLOCK
WALLS,
OR
DRIVEWAY
Page 3
Application Number
. . . . .
l"
Page 3
Application Number
. . . . .
04-00006283 Date
' 9/14/04
----------------------------------------------------------------------------
Special Notes and
Comments
APPROACH
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
63.86
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
19.71
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary
-----------------
Charged
----------
Paid Credited
----------
Due
Permit Fee Total
1356.28
--------------------
.00 .00
1356.28
Plan Check'Total
728.33
.00 .00
728.33
Other Fee Total
2488.57
.00 .00
2488.57.
Grand Total
4573.18
.00 .00
4573.18
PREPARED 3/15/11,
12:45:52
INSPECTION HISTORY REPORT
PAGE 1
PROGRAM
BP521L
0/00/00
THRU 0/00/00
CITY OF
LA QUINTA
------------------------------------------------------------------------------------------------------------------------------------
APPLICATION
PROPERTY ADDRESS
APN
Alternate ID
STRUCTR
------------------------------------------------------------------------------------------------------------------------------------
PERMIT
INSPECTION
RESULT DATE/STATUS
INSPECTOR
04 00006283
60282 ANGORA CT
764-270-999-119.-300233-
000
000
B001
00
BUILDING
PERMIT
120
0001
FOOTINGS
11/04/04
APPROVED
ST
000
000
B001
00
BUILDING*PERMIT
125
0001
SLAB
11/04/04
APPROVED
ST
000
000
B001
00
BUILDING
PERMIT
135
0001
ROOF NAIL
12/10/04
APPROVED
GH
000
000
B001
00
BUILDING
PERMIT
140
0001
OKAY TO WRAP
12/22/04
APPROVED
GH
000
000
B001
00
BUILDING
PERMIT
145
0001
FRAMING
12/23/04
APPROVED
GH
000
000
B001
00
BUILDING
PERMIT
150
000I
INSULATION
12/28/04
APPROVED
GH
000
000
8001
00
BUILDING
PERMIT
155
0001
LATH
1/04/05
APPROVED
GH
000
000
B001
00
BUILDING
PERMIT
160
0001
DRYWALL NAIL
1/04/05
APPROVED
GH
000
000
E01
00
ELEC-NEW
RESIDENTIAL
310
0001
ROUGH ELECTRICAL
12/23/04
APPROVED
GH
.000
000.
MO1
00
MECHANICAL
405
0001
ROUGH MECHANICAL
12/23/04
APPROVED
GH
000
000
PO1
00
PLUMBING
210
0001
SEWER CONNECTION
10/28/04
APPROVED
ST
000
000
PO1
00
PLUMBING
200
0001
UNDERGROUND PLUMBING
10/28/04
APPROVED
ST
• 000
000
PO1
00
PLUMBING
230
0001
ROUGH PLUMBING
12/23/04
APPROVED
GH
000
000
PO1
00
PLUMBING
245
0001
SHOWER PAN
12/23/04
APPROVED
GH
000
000
PO1
00
PLUMBING
235
0001
GAS LINE / GAS TEST
1/28/05
APPROVED
GH
02/04/2005 04:05 17603401819PAGE 05/21
11111111111111111 70
I E
INSULATION CERTIFICATE
This is to certify that insulation has been installed in conformance with the current energy
regulation, California Administrative Code, Tfffe 24, State of California, in the building at
60-282 ANGORA CT, LOT 3119, PHASE 8A, LA QUINTA CA
CEILINGS:
TYPE: BLOW MANUFACTURER: Certainteed
THICKNESS: R-38
WALLS:
TYPE: BLOW MANUFACTURER: Certainteed
THICKNESS. R -13
GENERAL CONTRACTOR: SHEA HOMES LICENSE #
BY: TITLE:
PARAGON. SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221617
BY. TITLE, ACCOUNT REPRESENTIVE DATE:
wit\I •
` jEN I'IDAC Installation Certificate: Residential CF -6R
AIR CONDITIONING INC.
Site Address PERMIT #
60-282 ANGORA COURT G a
1. BUILDER INFORMATION
SHEA TRILOGY LA QUINTA
81260 AVE 62
LA QUINTA, CA 92253
INSTALLING CONTRACTOR:
2. PROJECT INFORMATION
DISTRIBUTION TYPE
Flexible Ductwork in
Attic and Between Floors
SUBDMSION: Trilogy La Qunita
CITY: LA QUINTA
COUNTY: RIVERSIDE
WESTPAC AIR CONDITIONING
DICT OR PIPING R -VALUE
Flexible Ductwork Will have
a R -Value of 6.00 or Better
111111111111 III111111111 71
IE
I, the undersigned, verify that the equipment listed in the category above my signature is the equipment installed and that the equipment mee
or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more
efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate complience with the Energy Efficiency
Standards for residential buildings.
3. HEATING INFORMATION
HEATING MANUFACT HEATING UNITACTUAL EFF. HEATING EQUIP HEATING
EQUIP. MAKE MODEL # AFUE CAPACITY LOAD
4. COOLING INFORMATION
COOLING MANUFACT COMPRESSOR I ACTUAL EFF. COOLING EQUIP HEATING
EQUIP. —11 MAKE MODEL # SEER CAPACITY LOAD
The building design heat loss and design heat gain rate have been determined using a method specified in Section
150(h) of the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection.
5. THERMOSTATIC EXPANSION VALVE (TXV):
Thermostatic Expansion Valve (or Commision approved equivalent) is installed and access is provided for inspection.
6. SUBMITTED BY:
__a=c O • I
Signature Installing HVAC Contractor
Alexis\CrystalReports\Purchasing\CF6R Report.rpt
nh#: 4514 T nt: 3119
YES Q NOF --j N/AF--]
Date
a
N
:n
O
d
N
N
N
.a
O
L
O
O
C
D
Ci
N
a
"D
C
m
N
O
Q
d
N
C
O
v-
U
Lb
0
a
CL
a
v
CL