Loading...
08-0298 (SOTB)fi F IIIIIIIIIIIIIIIIIIIIIN 44 P.O. BOX 1504 IE 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 <i&tiv4,4Q" Application Number: 08-00000298 Property Address: 81703 ANDALUSIA APN: 764-200-999-64 -316813- Application description: STRUCTURES OTHER THAN BUILDINGS Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 1000 Applicant: Architect or Engineer: NI& BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that Ian licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cl ss: C8 C27 C29 License No.: 656128 Date: / �% Contractor: O NER-BUILDER DECLARATION I hereby affirm under penalty of perjury t at I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001.: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , 8.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: FREI RESIDENCE 81-703 ANDALUSIA LA QUINTA, CA 92253 Contractor: TESERRA P.O. BOX 1280 COACHELLA, CA 92236 (760)398-9222 Lic. No.: 656128 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/14/08 ff5 2.3 qTY OF a, QyfPtTA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier SEABRIGHT Policy Number BB1080510 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be( Dme subject to the workers' compensation laws of California, and agree that, i*WOERS' subject to the workers' compensation provisions of Section 3700 of the Labthwith comply with those provisions. Date: '-�PPlicant: WARNING: FAILURE TO SECURMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above i formation is correct. I agree to comply with all city and county ordinances and state laws relating to buI g con ruction,and hereby authorize representatives of this county to en er upon the above-mentioned propor msp ction purposes. Date: ignature (Applicant or Agent I -J LQPERAIIT Application Number . . . . . 08-00000298 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 25.00 Plan Check Fee 16.25 Issue Date . . . . Valuation . . . . 1000 Expiration Date . . 8/12/08 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 2.0000 HND BLDG --------------------------------------------- 501-2,000 ----------------------------- 10.00 Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 17.25 Plan Check Fee 4.31 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/12/08 Qty Unit Charge Per' Extension BASE FEE 15.00 3.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 2.25 ---------------------------------------------------------------------------- Special Notes and Comments BBQ/FIREPIT PER APPROVED PLAN Fee summary Charged ----------------- Paid Credited Due -------------------- Permit Fee Total 42.25 ------------=------- .00 .00 42.25 Plan Check Total 20.56 ..00 .00 20.56 Grand Total 62.81 .00 .00 62.81 Bin # Permit # $� Project Address: Aur City ®f La Quint Building 81 Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Applicati®n and Tracking Sheet Bim - Owner's Name: L� r A. P. Number: Address: Legal Description: Contractor: 7.�A- City, ST, Zip: Telephone: t Address: P.(/") �'j � ;IC, 0 Project Description: City, ST, Zip: tL-�13-120 a" Telephone: •y/ 4 :/ Y d-.' G: i. S5^CY.f}'� ,."a: 1Y/c f..�.,±'.'v �R�;i, - State Lic. #: r r'. -A ;,r � � Arch., Engr., Designer: City Lic. #: Address: City, ST, Zip: Telephone: State Lic. Name of Contact Person: .J'5 C �,.+ �ltr , ,r�� +� Construction Type: Occupancy: 'Yua'"3� Project type (circle one): Ne��)Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: timated Value of Project: 000 APPLICANT:'DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted - Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction Flood plain plan Plans resubmitted mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor hist Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading fN HOUSE:- "' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees . N GRILL -� Q LIGHT N O w w PRE -HUNG S.S. DOORS O O Iv— x STUCCO OR STONE \ VENEER GF OUTLET LIGHT SWITCH (WATERPROOF) I.C.B.n. # FREE-STANDING OUTDOOR KITCHEN FRONT ELEVATION ANSI U #i i fl 1/2"=1'-0" U.L. APPROVED. LIGHT I w GRILL I > I F n FREE-STANDING OUTDOOR KITCHEN PLAN ADAPT DIMENSIONS =C # TO FIT APPLIANCES 6x8x16 CMU; GROUT .CELLS WITH STEEL — — —#4 BARS VERT. AT 24° 0.C_(TYP.) BBQ LAYOUTS MAY VARY. "' FOOTING SIZE B,REINF. ARE TYPICAL. I FNGTN VARIGC �J - vvivvr� i wIV (-LAN N STONE CAP, TILE POURED CONC. #4 BAR HORIZ. AT 3° 32° O.C. (TYP.) 6X8XI6 CMU CNJ GROUT CELLS WITH STEEL #4 BAR F.S. VERT. AT 24° O.C. (TYP.)• 2-# 4 BARS HORIZ. CONT. t` VARIES b° FREE-STANDING BBQ - WALL SECTION BBQ ISLAND - SIDE ELEV. STAINLESS STEEL SINK PROVIDE VENT; STONE OR NIASTE, AND PLUMBING FOR SINK ON SEPARATE TILE CONSTRUCTION DOCUMENT. COUNTER Iv— x STUCCO OR STONE \ VENEER GF OUTLET LIGHT SWITCH (WATERPROOF) I.C.B.n. # FREE-STANDING OUTDOOR KITCHEN FRONT ELEVATION ANSI U #i i fl 1/2"=1'-0" U.L. APPROVED. LIGHT I w GRILL I > I F n FREE-STANDING OUTDOOR KITCHEN PLAN ADAPT DIMENSIONS =C # TO FIT APPLIANCES 6x8x16 CMU; GROUT .CELLS WITH STEEL — — —#4 BARS VERT. AT 24° 0.C_(TYP.) BBQ LAYOUTS MAY VARY. "' FOOTING SIZE B,REINF. ARE TYPICAL. I FNGTN VARIGC �J - vvivvr� i wIV (-LAN N STONE CAP, TILE POURED CONC. #4 BAR HORIZ. AT 3° 32° O.C. (TYP.) 6X8XI6 CMU CNJ GROUT CELLS WITH STEEL #4 BAR F.S. VERT. AT 24° O.C. (TYP.)• 2-# 4 BARS HORIZ. CONT. t` VARIES b° FREE-STANDING BBQ - WALL SECTION BBQ ISLAND - SIDE ELEV. GAS- SHUTOFF GAS LINES SHALL BE INSTALLED VALVE GRAVEL PER CPC FOR DEPTH, LOCATED COURSE COVERAGE, AND PLACEMENT.. WITHIN 36" GAS LOG SAND WATER PROOF OF UNIT LIGHTER MEMBRANE (TYP.) STONE CAP,, 3-I/2' #4 TIE STEEL #4 BAR VERT. AT 32" O.C. 8x8x8.CMU; SOLID GROUT CLR METAL GAS RISER GRAVEL SUMP 2" DRAIN OR PROVIDE 12" DIAM. 3 CU. FT. OPENING IN FOOTING CRUSHED ROCK 7A OUTDOOR FIRE RING - STONE CAP 1/2"=1'-0" r ' #4 TIE t � -STEEL AT 36" DIAM. TOP COURSE GAS FIRE RING: INSIDE DIMENSION WATERPROOF MEMBRANE I.C.B.O. #, ANSI # (TYP. INTERIOR SURFACES) ` BTU / `�% #4 BAR VERT AT U.L. APPROVED. 32" O.C. + (TYP.) 7A 7B OF GAS PIPE 6x8x8 OR JLENGTH DIAM. OF GAS PIPE'` 8x8x8 CMU, SOLID GROUT 7 OUTDOOR FIRE RING I/2"=1'-0" GAS- SHUTOFF GAS LINES SHALL BE INSTALLED VALVE GRAVEL PER CPC FOR DEPTH, LOCATED COURSE COVERAGE, AND PLACEMENT.. WITHIN 36" GAS LOG SAND WATER PROOF OF UNIT LIGHTER MEMBRANE (TYP.) STONE CAP,, 3-I/2' #4 TIE STEEL #4 BAR VERT. AT 32" O.C. 8x8x8.CMU; SOLID GROUT CLR METAL GAS RISER GRAVEL SUMP 2" DRAIN OR PROVIDE 12" DIAM. 3 CU. FT. OPENING IN FOOTING CRUSHED ROCK 7A OUTDOOR FIRE RING - STONE CAP 1/2"=1'-0" t � Xref 5\ XO549--L?5-outs,dwo