Loading...
13-0678 (RPL)IIIIIIIIVIIIIIIVIIIIIII 46 IE UM& P.O. BOX 1504 c&ht 78-495 CALLE TAMPICO 44,,, LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 13-00000678 Owner: Property Address: 81711 ANDALUSIA TAZELAAR APN: 764-670-035- - - 81711 ANDALUSIA Application description: POOL - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL (760) 000-0000 Application valuation: 29000 C==== C" Contractor: Applicant: Architect or Engineer: O ? Q TESERRA N OQC P.O. BOX 1280 JU1 COACHELLA, CA 92236 \ LLZ (760) 398-9222 `\ a 04 Lic. No.: 656128 4p'1 LLL ____________________ ___________________ L LIN D CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that a licensed under provisions of Chapter 9 (commencing wit Section 70001 Division 3 of the Business a Professionals Code, and my License is in full force and effect. LicenseClas C8 10,27,2 LicenseNo.: 656128 S Date ' Contract. VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/30/13 - - - - --------------------------------------- - - - - -- OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPFRA1IT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. f_rhave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Vi�' Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EVEREST NATL INPolicy bre 7600006481131 I certify that, in the performance of the for which this permit is issued, I shall not employ any person in any manner so as to b7eiect ubject to the workers' compensation laws of California, nd agree that, if I should becomto the workers' compensation provisions of Section 70 of the Labor Code, I shall th comply with those provisions. J ,�r� Date. Applicant. v WAR ING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS IS100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null ndvoid if work is not commenced within 180 days from date of issuance of such permit, or sation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above inf ation is correct. I agree to comply with all city and county ordinances and state laws relating to building cons coon, and hereby authorize representatives of this' ounty t en r upon the above-mentioned property for i ection purposes. Date. Signature (Applicant or Agentl� 0 Application Number . . . . . 13-00000678 Permit . . . . . POOL 2013 Additional desc . . Permit Fee . . . . 178.75 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/26/13 Qty Unit Charge Per Extension 1.00 178.7500 EA MISC POOL/SPA ---------------------------------------------------------------------------- 178.75 Permit PLUMBING Additional desc . Permit Fee . . . . 18.00 Plan Check Fee 4.50 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/26/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments POOL AND SPA AT REAR YARD, 167LF OF 2 GAS LINE FOR FIRE BOWL THIS PERMIT DOES NOT INCLUDE BBQ OR WATER FEATURES. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2010 CALIFORNIA BUILDING CODE. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, POOL 97.24 Fee summary Charged Paid Credited --------------------------- Due ------------------------------ Permit Fee Total 196.75 .00 .00 196.75 Plan Check Total 4.50 .00 .00 4.50 Other Fee Total 98.24 .00 .00 98.24 Grand Total 299.49 .00 .00 299.49 LOPEPMIT Bln,# w Clty of. U Quints Building 8T Safety Division P.O. Box 1504,78-495 Calle Tampico U.Qutnta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # J l(�66OQ Project Address I� q Owner's Name: �ZE (AArZ A. P. Number. Address: �r Legal Description: JI City, ST, Zip: (A ©ME Contractor -Telephone: Address: IO 116 S YProject Description: Etv ©© c— City, ST, Zip:ce—Itf _ (.. f 22 7 a -Ce AAJI—> o . Telephone: i V. �J. c'-. =t --z F'r ?i✓ IS State Lie. # :r % Z City Lia #: Arch., Engr., Designer. f Address: City, ST, Zip: Telephone: Construction Type:. Occupancy: State Lic. #: project type (circle on N ' Add',. Alter Repair Demo Name of Contact Person: Sq. Ft.; #Stories: _T# Units: Telephone # of Contact Person: ?60 ?_/P, Estimated Value of Project: �/ © 00. APPLICANT: DO NOT WRITE BELOW THIS LINE P Submittal Req'd Reed TRACMG PERMIT FEES Plan Sets Pian Check submitted I Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. Called Contact Person Plan Check Balance • Title 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan Review, ready for correctionsfissue Electrical Subcoutactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit Issue School Fees l r , APPROVED FOR CONSTRUCTION . DATE . 8 Tow! Permit 01 MAY 2 9 201j CI7Y pF . COMMUNI QUID11 TY �EVEt D MENT i, NO EXISTING LANDSCAPE LIGHTING IN REAR YARD NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY THREE DECK EMITTERS WITH DEDICATED PUMP SPA AT 0" WITH TILE DAM WALL AND 6 JETS TANNING SHELF AT 6" WATER DEPTH WITH THREE UMBRELLA SLEEVES, LOCATION T.B.D. NATURAL GREY BROOM FINISH CONCRETE STEPPING PADS POOL / SPA LIGHT JUNCTION BOX POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER NATURAL GREY BROOM FINISH CONORETE DECKING WITH #4 REBAIR 16" o.c. REINFORCED POOL EQUIPMENT 50 AMP SUBPANEL WITH 30" CLEARANCE AT FRONT AND SIDE POOL EQUIPMENT: 400,000 BTU HEATER *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED ELECTRIC CONDUIT 167'- 2" POLYPROPYLENE GAS PIPE OVERFLOWING POT WATERFEATURE WITH INTERMATIC TIME CLOCK, POWER TO BE SOURCED OFF CASITA ELECTRICAL OUTLET MAIN HOUSE 200 AMP ELECTRICAL PANEL EXISTING PAVER DRIVEWAY TO REMAIN INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL SHALL BE INSTALLED PER MANU FACTURER'S POOL HEATERS / PUMP EQUIPMENT RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS r woAnlclnnl irvNTS FOR REPRESENTAION ONLY, WROUGHT IRON (FENCE AND GATE AT +30" 1410 SQ.FT. PM-ARERnA, ur' L 418 SQ.FT. COURTYARD AREA NATURAL GREY DECKING 72 SQ.FT. PORTICO RECESS CONCRETE DECKING THREE DECK EMITTERS WITH DEDICATED PUMP SPA SPLIT MAIN DRAIN SUCTION MINIMUM T APART. ANTI -COVERS 10" ASME / ANSI APPROVED POOL SPLIT MAIN DRAIN SUCTION MINIMUM T APART. ANTI -COVERS 10" ASME / ANSI APPROVED GRAND EFFECTS FIREPIT WITH GLASS MEDIA POURED POLISHED CONCRETE COUNTERTOP AT +36" WITH ALX -42 ALFRESCO BARBECUE, OLC42 STAINLESS STEEL SINGLE DOOR/2 DRAWER COMBO, OLC-24 ICE BIN, FLEX LIGHT, TWO ELECTRICAL OUTLETS, TWO UMBRELLA SLEEVES, STUCCO EXTERIOR TO MATCH HOUSE NATURAL GREY BROOM FINISH CONCRETE WALKWAY RECESS CONCRETE FOR FUTURE TILE BY OTHERS TYPE GUNITE SIZE 40'-V' X 21FAK SURFACE AREA OF POOL ONLY 788 SQ FT. PERIMETER 146 LN. FT. DEPTHS MIN. T-0" MAX S- POOL & SPA COMBINED 87180, FT / 124 LN FT SPA SPECIFICATIONS TILE SIZE 10'-0"X 6'-0" SQ. FT. 60 LN. FT. 32 TILE TYPE T.B.D. WATERLINE YES SPA DAM WALLWIDTH 12" TILE NO. OF JETS 6 LIGHT 1 - 100W TRIM QUARTER ROUND — R.B.B. TILE — RAISED SPA AT 0" SPILLWAY TYPE TILE DE C K I N G SPECIAL NOTES EXCAVATION / 5TttL_ TYPE BOBCAT ACCESS FROM STREET / SIDE LOT ELEVATION T.B.D. DEEP END RAMP NO LOVE SEAT NO CONCRETE REMOVAL 371 SQ. FT. SOD REMOVAL YES TREE REMOVAL BY NO IRRIGATION REMOVAL BY NO IRRIGATION REPAIR NO 6" R.B.B. POOL 12" R.B.B. -- 18" R.B.B. 24" R.B.B. — 30" R.B.B. — TAN SHELF DEPTH 6" WD ROCK POCKETS NO CENTERS NO SAFETY FEATURES: * ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) ELECTRICAL: EQUIPOTENTIAL BONDING REQUIREMENTS SHAILL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ARTT. 680.26. 20 1 O CALIFORNIA BUILDING CODE (BASED ON2000IBC) 20 1 O CALIFORNIA MECHANI CAL CODE (BASED ON2006UMC) ZO 1 O CALIFORNIA PLUMBINIG CODE (BASEDON2WgUPC)TRLGX-- 20 1 ❑ CALIFORNIA ELECTRICAL CODE (BASED ON 2006 NEC) 201 O CALIFORNIA ENERGY IEFFICIENCY STANDARDS GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR COMMENCING THAT EXCAVATION, IF 7HE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED CONSTRUCTION AUTHORIZATION SALES FIELD DIG PRE-GUNITE UNDERGROUND MASONRY DECK PRE -PEBBLE T-,-, PLUMBING FILTER JANDY SIZE 580 SQ.FT. POOL PUMP JANDY SIZE 2.0 HP VARIAB BOOSTER PUMP — SIZE _--- ADDL PUMP JANDY SIZE 0.75 HP ADDL PUMP — SIZE '— HEATER JANDY LXI SIZE 400,000 BTU TIME CLOCK JANDY ONE TOUCH SUB PANEL PURELINK ADDL OUTLETS AT BARBECUE SKIMMER TYPE DUAL PORT FILL LINE AUTO GAS LINE 2" STUBS YES FOUNTAINS/ SPRAYHEADS 6 DECK JETS SHEER DESCENTS NO LIGHTS IN POOL 3 IN SPA 1 STUB SET EQUIPMENT YES MISC PLUMBING SIZE 21/2" SUCTION & 2 1/2" RETU SPA 3" SUCTION & 3" RETURI GUNITE DEEP END RAMP NO EXTEND 2nd STEP NQ LOVESEAT NO SPILLWAY TYPE TILE CANTILEVER YES COPING PIP CONCI R.B.B. - SEE STEEL +6' SO. FT, SEE NOTE FINISH GRAY BROOM FINISH EXPANSION JOINTS AS NECESSARY CANTILEVER PIP CONCRETE DECK DRAINS YES AS NECESSARY DECCO DRAIN CURB CORE — STEPS STEP FACE POOL 6" STEP FACE TILE BASE YES AT PORTICO SAND AND VISQUEEN YES RIBBONS — MOW STRIP — MASONRY COPING TYPE PIP CONCRETE R.B.B. FACING NO SPILLWAY TYPE TILE SIZE STEPS — PROP. EXT. WALLS —" PLANTER WALL RETAINING WALLS — EQUIP. WALLS — FIREPIT LEBBL LIM 3 LIGHTS SPA 1 ROLLED BOND BEAM = BEHIND SPA — FENCING FENCE TYPE +30 WROI HEIGHT GATE YES GATE REVERSAL NO REMOVE & REHANG NO EST. START JUINP - 151 - "IJ EBT. COMPLETION AUGUST - 31 st - 2013 DTH ER JANDY PURELINK SALT WATER OWNER RESPONSIBILITIES OWNER TO: (1) DETERMINE THE APPROXIMATE ELEVA CION Ot POui_ OR SPA AT LAY':; UT CN DAY OF EE— CAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (8) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS - DO NOT USE RUBBER HOSE) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. SIGNATURE(S) DATE SWIMMING POOL PLAN FOR: 4AME TAZEL_AAR RESIDENCE STREET 81-711 ANDALUSIA JOB ADDRESSANDALUSIA C.C. CITY LA QUINTA PHONE OFFICE RES LOT H-65 TRACT PAGE BOOK MAP BOOK PAGE NO CITY MAIL ADDRESS CONSTRUCTION OFFICE PHONE NO. SCALE DATE DESIGNED BY PROJECT MGR. CHECKED BY III 11= 1 1 05-28-13 JT. PAUL Y, JOB# REVISIONS DATE: SELECTIONS FIREBOWL t mmvav r-rrr-%, 1 o rir« vvvvi- COLOR AND GLASS MEDIA COLOR T.B.D. TILE T.B.D. BOULDERS N/A DECK COLOR 0 JANDY RS6 "ONE TOUCH" WITH AQUA PALM REMOTE PEBB/PLAS PEBBLE SCAPE "FRENCH GRAY" MINI PEBBLE SIGNATURE 11 DRAINAGE NOTE: Drainage and irrigation for planters and pots, by others, unless otherwise noted.