07-1022 (SOTB)58290 Aracena
IIIIIII VIII III VIII (III 53
'u l'Gv
P.O. BOX 1504 IE
.
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
Application Number:0
7-00-00-0-1-0-2 =2
Property Address:
58290 ARACENA
APN:
764-200-999-36 -316812-
Application description:
STRUCTURES OTHER THAN BUILDINGS
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
1500
Applicant:
Architect or Engineer:
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the ausi and Professionals Code, and my License is in full force and effect.
License Class: B C53 License No.: 552140
'`(i'51 ontractor
C OWNER -B ILDER D RATION
I hereby affirm under penalty of perjury that I am exempt om o actor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions C e: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).:
1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.I.
Lender's Name:
Lender's Address: P 11A
LQPERA11T
Owner:
DONALD & RENATA TURNER
58290 ARACENA
LA QUINTA, CA 92253
VOICE (760) 777-7012
FAX (760) 777-701.1
INSPECTIONS (760) 777-7153
Date: 4/03/07
Contractor: FtAP!R
BRYAN INVESTMENTS GROUP,
P.O. BOX 1804 'u 2007
PALM SPRINGS, CA 92263
(760)345-8483
Lic. No-.: 552140 CITY O wrnnknT s
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier CLARENDON NATL Policy Number 01DKRM21000978
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
-and agree that, if I should become subject to the workers' compensation provisions of Section
i J NO of the La r r^dP, I shnall with comply with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPE ATION RAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES A32.PVM FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT _
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to•the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this ounty to enter upon t above-mentioned pro insp ion purposes:
49VIQA' nature (Applicant or Agent):
Application Number . . . . 07-00001022
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
35.00
Plan Check
Fee
22.75
Issue Date
Valuation
. . .
. 1500
Expiration Date
9/30/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
10.00 2.0000
----------------------------------------------------------------------------
HND BLDG 501-2,000
20.00
Permit
PLUMBING
Additional desc .
Permit Fee . . . .
21.00
Plan Check
Fee
4.50
Issue Date . . . .
Valuation
. . .
. 0
Expiration Date
9/30/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 3.0000
EA PLB GAS PIPE 1-4 OUTLETS
6.00
----------------------------------------------------------------------------
Special Notes and Comments
FIREPIT & BBQ, PER APPROVED
PLANS
-----------------------------------------------7----------------------------
Other Fees. . . .
. . . . .ENERGY
REVIEW FEE
2.28
STRONG
MOTION (SMI)
- RES
.50
Fee summary Charged
---------------------------
Paid Credited
-------------------------------
Due
Permit Fee Total
56.00
.00
.00
56..00
Plan Check Total
27.25
.00
.00
27.25
Other Fee Total
2.78
.00
.00
2.78
Grand Total
86.03
.00
.00
86.03
LQPERMIT
GAS-FIRED
C UOL US
LISTED
'HEAT N-GLOE
Lifekyle Products
1111111111111111111111111 54
IE
INSTALLATION & OPERATING
INSTRUCTIONS
PATIO CAMPFIRE
IMPORTANTI Read all instructions carefully before
starting installation. Failure to follow these installa-
tion instructions may result in a possible fire hazard
and will void the warranty.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
fireplace.
— What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
This manual must be used for installation and retained by the homeowner for operation and maintenance. Save this manual for
future reference)
If you have questions or concems, please contact the Technical Services Dept., Hearth 8 Home Technologies Inc., 1-800-927-6841
or 1-888-427-3973. .
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4852,548; 4,875,464, 5,000,162; 5,016,609; 5,076,254; 5,191,877; 5,218,953; 5,328,355; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
08/04 4004-001 Rev C
HEA`- N-GLO-
L feStylc Pruducis PATIO CAMPFIRE INSTALLATION INSTRUCTIONS
CONTENTS
AIntroduction
...............................................................................:..................................................................................
2
B.
Safety Information.........................................................................................................................................................
3
C.
Components and Installation.......................................................................................................................................
4
D.
Operating Instructions................................................................................................................................................
.. 8
E.
Maintenance Instructiens.............................................................................................................................................
9
F.
High Elevation Installation............................................................................................................................................
9
GReplacement
Parts......................................................................................................................................:.............
10
Warranty......................................................................................
....................................................:........................... 12
A. INTRODUCTION
This appliance is a Decorative Gas Log Set for OUTDOOR USE ONLY and MUST NOT be used for cooking.
Place this appliance on a flat and stable surface in an outdoor location such as a patio or deck. This location must be adjacent to the
gas supply line or LP gas supply cylinder. DO NOT locate the appliance where it can get excessively wet or submerged in water.
The following clearances to combustibles must be maintained:
Bottom - 0 in., Sides/Walls (all around) - 24 in. (610 mm), and Top - 8 it (2.4 m).
A decorative surround can be made from noncombustible material (such as bricks, landscape blocks, rocks, etc.) or two models of
fabricated surrounds are available (see below).
Rock Ring
Mesa
Always keep the appliance area clear and free from combustible materials, gasoline and any other flammable vapors and liquids.
2 4004-001 Rev C 08/04
M
Y
PATIO CAMPFIRE INSTALLATION INSTRUCTIONS
B. SAFETY INFORMATION
The Patio Campfire has been tested in accordance with IAS US
requirements for Outdoor Gas Fireplaces, Draft 4-96 and ANSI
221.58-1995/CGA 1.6-M96 for Canada and has been listed by
Underwriters Laboratory (UL) for installation and operation as
described in these installation and operating instructions.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code ANSI 2223.1 or
CAN/CGA-B149.1, National Gas Installation Code or CAN/CGA-
B149.2, Propane Installation Code.
IMPORTANT: Installation of natural gas should be done by a
qualified installer, service agency or gas supplier.
The appliance and its manual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of the system at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas supply piping
system by closing its manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal
to or less than 1/2 psig (8.5kPa).
Note: All new LP cylinders (and in many cases used cylinders)
may contain water, air or other contaminants. It is essential.
that these substances be released before filling the cylinder
and placing into service. Water vapor present in the gas vapor
may cause the regulator to "freeze up" and cause an
interruption to the gas flow. This interruption will cause the
appliance to shut down. To prevent this from occurring, it is
essential that a qualified individual always purge a new tank
thoroughly before placing it into service. It is recommended
that cylinders that have not been used for extended periods of
time also be purged before use.
• , Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid bums
or clothing ignition.
Young children should be carefully supervised when they
are in the area of the appliance.
Never leave the appliance unattended during operation.
HEAT N -GELD"
Lr feStyle Producer
• Clothing or other flammable materials should not be placed
on or near the appliance.
• Any guard or other protective device removed for servicing
the appliance must be replaced prior to operating the
appliance.
• Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and
at least annually by a qualified service person. More frequent
cleaning may be required as necessary. It is imperative that
the control compartment, burners and circulating air
passageways of the appliance be kept clean.
• Inspect the fuel supply connection (including the hose for
LP models) before each use of the appliance.
• If it is evident there is excessive abrasion or wear, or the
hose is cut, it must be replaced prior to the appliance being
put into operation.
• The pressure regulator and hose assembly supplied with
LP models must be used. Replacement pressure regulators
and hose assemblies must be those specified in this
manual
• The LP gas supply cylinder used with LP models must be
constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S. Department of
Transportation (DOT).
• Cylinders must be stored outdoors in a well ventilated area
out of the reach of children. Disconnected cylinders must
have threaded valve plugs tightly installed and must not be
stored in a building, garage or any other enclosed area.
• Storage of this appliance indoors is permissible only if it
has been disconnected from its fuel supply (natural gas line
or LP gas cylinder).
• The LP gas cylinder supply system must be arranged for
vapor withdrawal.
• The LP gas cylinder used must include a collar to protect the
cylinder valve.
• When an LP model is not in use, the LP gas must be turned
off at the supply cylinder.
Note: Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.
08/04 4004-001 Rev C
HEAT N-19LO-
L feStylc Producrs
PATIO CAMPFIRE INSTALLATION INSTRUCTIONS
C. COMPONENTS AND INSTALLATION
The burner assembly and log assembly are packaged individually and shipped in one carton. See illustrations below.
Natural Gas Propane
Sumer Assembly Locating Button BumerAssembly
(Align with dimple on bottom of log base)
\ r
Heat Shield
Regulator Hose
Flex Tube (Propane only)
ONIOFF Valve /
Burner Assemblies
Log #1
Log #2
Log #3
Log #4
Log Base
4 4004-001 Rev C 08/04
PATIO CAMPFIRE INSTALLATION INSTRUCTIONS HEA L.Ny lc ALd ct`
1. BunnerAssembly
a. All Models
1) Remove the burner assembly and check for
damage. Do not use damaged components.
2) Position the burner assembly in the desired
location.
This location must be adjacent to the gas supply
line.
You must have easy access to the gas valve control
knob after it is installed and connected' the gas
supply because the ON/OFF gas valve is used to
tum the burner on and off.
b. Natural Gas Models
1) Connect the ON/OFF gas valve of the appliance to
the incoming gas supply line. See Figure 1. Make
certain all gas connections are tight.
2) Tum the ON/OFF valve at the appliance slowly to
the "ON" position. All connections must be tightened
and checked for leaks with a commercially
available, non -corrosive leak check solution. Be
sure to rinse off the solution when done leak testing.
Locating
"ON/OFF" Button \
Valve \\
i
Check fittings Heat Shield
for leaks
Figure 1
Natural Gas Burner Assembly
08/04 4004-001 Rev C
c. LP Gas Models
1) Make sure the tank valve is turned completely off
(clockwise).
2) Ensure the tank valve has the proper external mating
threads (tank valve marked "USE WITH TYPE 1").
3) Inspect the hose shipped with the appliance for
any damage. Do not use if there is evidence of
damage.
4) Connect the end of the hose onto the ON/OFF gas
valve of the appliance. Make sure it is secured tightly.
5) Connect the regulator assembly to the tank valve.
Hand tighten only (clockwise). Do not use a wrench
to tighten! Use of a wrench may damage the quick
closing nut and result in a hazardous condition.
See Figure 2.
6) Position the hose out of pathways where people
might trip over it or in areas where the hose might
be subject to accidental damage.
7) Open the tank valve fully (counterclockwise). Tum
the ON/OFF valve slowly to the "ON" position. All
connections must be tightened and checked for
leaks with a commercially available, non -corrosive
leak check solution. Be sure to rinse off the solution
when done leak testing. If a leak is found, tum the
tank valve off and do not use the appliance until
repairs can be made.
"ON/OFF' Burner
Gas Valve locating Assembly
Flex Button \
Connector \
fI i
Propane Check fittings Heat Shield
Regulator Hose for leaks
Figure 2
Propane Burner Assembly