Loading...
13-0849 (RPL)58298 Aracena r P.O. BOX 1504 _ IE 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 57 • VOICE (760) 777-7012 7 .,1 b FAX (760) 777-1011 BUILDING & SAFETY DEPARTMENT 40 INSPECTIONS (760) 777-7153 BUILDING PERMIT Application Number: 13-00000849 Property Address: 58298 ARACENA APN: 764-200-999-37 -316812- Application description: POOL- RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 27000 Appljc nj: v Architect E: ----------------------------—--------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C8 , 10, 27 , 2 License No.: 656128 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions, Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Date: 7/11/13 Owner: T D DEVELOPMENT 81570 CARBONERAS LA QUINTA,' CA 92253 Contractor: TESERRA P.O. BOX 1280 COACHELLA, CA 92236 (760)398-9222 Lic. No.: 656128 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor _ Code, for the performance of the work for which this permit is issued.- My workers' compensation insurance carrier and policy number are: Carrier EVEREST NATL IN Policy Number 7600006481131 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT ' IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): M LQPERMIT Application Number . . . . . 13-00000849 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/07/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 ---------------------------------------------------------7------------------ 23.83. Permit . . . POOL 2013 Additional desc . . Permit Fee . . . . 178.75 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/07/14 Qty Unit Charge Per Extension 1.00 178.7500 EA MISC POOL/SPA ----------------'------------------------------------------------------------ 178.75 Permit . . . PLUMBING 2013 Additional desc . . Permit Fee . . . . 11.92 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/07/14 Qty Unit Charge Per Extension 1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS 11.92 ---------------------------------------------------------------------------- Special Notes and Comments POOL & SPA, BBQ, FIREPIT,178 LN FT OF 2" POLYPROPELINE GAS LINE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2010 CALIFORNIA BUILDING CODE., ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, POOL 97.24 Fee summary Charged Paid Credited ------------------------------------------------------ Due Permit Fee Total 214.50 .00 .00 214.50 Plan Check Total .00 .00 .00 .00 Other Fee Total 98.24 .00 .00 98.24 Grand Total 312.74 .00 .00 312.74 * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD RAISED BOND BEAMIAT +18"/+24"/+30" WITH ACID *WASH FINISH COLORED CONCRETE CAP AND NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD * PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY TILE VENEER FACE, THREE ABS 1'-6" WIDE PLSHEER DESCENTS WITH DEDICATED PUMP AND PLUMBING TANNING SHELF AT WITH TWO UMBRELI ACID CONI 178'- 2" POLY 2" WATER DEPTH SLEEVES FIINISH COLORED DECKING NE GAS PIPE POOL EQUIPMENT 50 A44P SUBPANEL WITH 30" CLEARANCE T FRONT AND SIDE POOL EQUIPMENT: 400,000 BTU HEjIkTER *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED ECTRIC CONDUIT MAIN HOUSE 200 AMP HL.ECTRICAL PANEL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FACTURE 'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY, FIELD LAYOUT WILL VARY 166'-10" PL • e;® -�_ '551-15" 3'_c1l.—�_ +30" +24" j 5'-0'r LIPOOL WITH TILE WATERLINE AND PEBBLE TEC FINISH 12" US'* 11'-3" GAS — GA — GAS — GAS — S — GAS — GAS ` rVVL /'1l Vt'. 0 IMF-% �.nmi,,o4CL LJrXMIIV ASME/ANSI APPROVED -- - ---4JETS PA AT +12" WITH ACID WASH FINISH COLORED CONCRETE CAP, WIDE CONCEALED TILE LIP SPILLWAYS AND TILE VENEER FACE, ALTERNATE HEIGHTS PA AQUA STAR CHANNEL DRAIN ASME/ANSI APPROVED -- GAS — GAS — T-7"' SB. _w m" __"55'6".__ ARACENA 166'-8" 1 PL FIREPIT AT +9" WITH ACID WASH FINISH COLORED CONCRETE CAP AND TILE VENEER FACE GRANITE COUNTERTOP WITH 3" DROP EDGE AT +36" WITH 30" ALFRESCO BARBECUE, 30" STAINLESS STEEL SINGLE DOOR/DOUBLE DRAWER COMBO, FLEX LIGHT, STUCCO EXTERIOR TO MATCH HOUSE PRE FABRICATED FOUNTAIN WITH SUBMERSIBLE PUMP, COBBLE OVERLAY, INTERMATIC TIME CLOCK EXISTING WALKWAY TO REMAIN SPECIFICATIONS SAFETY FEATURES: * ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) SURFACE AREA OF POOL ONLY 442 SQ.FT. ELECTRICAL: EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26, POOL & SPA COMBINED 505 SOIL / 130 LN FT 20 1 ❑ CALIFORNIA BUILDING CODE (BASED ON2006IBC) 20 1 ❑ CALIFORNIA MECHANICAL CODE (BASED ON 2006 UMC) 20 1 ❑ CALIFORNIA PLUMBING CODE (BASED ON20AUPC)Tn... . 20 1 ❑ CALIFORNIA ELECTRICAL CODE (BASED ON 2006 NEC) 20 1 ❑ CALIFORNIA ENERGY EFFICIENCY STANDARDS TILE GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED TILE TYPE WATERLINE CONSTRUCTION AUTHORIZATION TILE TRIM SALES FIELD DIG R.B.B. TILE RAISED SPA AT PRE-GUNITE SPILLWAY TYPE UNDERGROUND SPECIAL NOTES DECKING MASONRY SQ. FT. 1419 SQ. FT. FINISH EXPANSION JOINTS EXCAVATION / STEEL TYPE DECK ELEVATION CANTILEVER PRE -PEBBLE DECK DRAINS _ SPECIFICATIONS TYPE GUNITE SIZE 40'-6" X SURFACE AREA OF POOL ONLY 442 SQ.FT. PERIMETER 119 LN.FT. DEPTHS MIN. 3'-0" MAX POOL & SPA COMBINED 505 SOIL / 130 LN FT SPA SPECIFICATIONS TILE SIZE 8'-0" X 6'-0" SQ. FT. 48 LN. FT. 28 TILE TYPE WATERLINE SPA DAM WALL WIDTH TILE TRIM NO. OF JETS QUARTER ROUND LIGHT R.B.B. TILE RAISED SPA AT SPILLWAY TYPE SPECIAL NOTES DECKING SQ. FT. 1419 SQ. FT. FINISH EXPANSION JOINTS EXCAVATION / STEEL TYPE ACCESS FROM ELEVATION CANTILEVER DEEP END RAMP DECK DRAINS LOVE SEAT DECCO DRAIN CONCRETE REMOVAL _LOADIS CURB CORE SOD REMOVAL LOADS STEPS TREE REMOVAL BY STEP FACE IRRIGATION REMOVAL BY TILE BASE IRRIGATION REPAIR SAND AND VISQUEEN 6" R.B.B. FT RIBBONS 12" R.B.B. MOW STRIP 18" R.B.B_ FT 24" R.B.B. FT 30" R.B.B. TAN SHELF DEPTH MASONRY COPING TYPE ROCK POCKETS CENTERS R.B.B. FACING SPILLWAY TYPE SIZE PLUMBING STEPS FILTER SIZE PROP. EXT. WALLS POOL PUMP SIZE PLANTER WALL RETAINING WALLS BOOSTER PUMP SIZE . WALLS ADDL PUMP SIZE EQUIP.FIREPI ADDL PUMP SIZE HEATER SIZE TIME CLOCK SUB PANEL ADDL OUTLETS SKIMMER TYPE FILL LINE PEBBLE / PLASTER GAS LINE STUBS LIGHTS POOL LIGHTS SPA FOUNTAINS / SPRAYHEADS ROLLED BOND BEAM SHEER DESCENTS BEHIND SPA LIGHTS IN POOL IN SPA EYEBALLS STUB SET EQUIPMENT —FENCING MISC PLUMBING SIZE FENCE TYPE PLUMBING HEIGHT GATE G U N I TE GATE REVERSAL DEEP END RAMP REMOVE & REHANG EXTEND 2nd STEP LOVESEAT SPILLWAY TYPE EST. START CANTILEVER EST. COMPLETION COPING OTHER R.B.B. - SEE STEEL OWNER RESPONSIBILITIES OWNER TO: (1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (8) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS - DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. SIGNATURE(S) DATE SWIMMING POOL PLAN FOR: NAME ANDALUSIA LOT B-37 STREET 58-298 ARACENA JOB ADDRESSANDALUSIA C.C. ICITY LA QUINTA PHONE OFFICE RES LOT B-37 TRACT PAGE BOOK MAP BOOK PAGE NO. ICITY MAIL ADDRESS CONSTRUCTION OFFICE PHONE NO. SCALE DATE DESIGNED BY PROJECT MGR. CHECKED BY g"= 1 ' 07-03-13 JT. PAUL Y. JOB# REVISIONS DATE: 1 2 31 41 cin of ua QUINTA PT. S APPROVED 6 %J %.0%.1NST-RUGT'0N 7UA[r- 13Y w 9 8 SELECTIONS STONE TILE BOULDERS DECK COLOR JAN DY PEBB/PLAS SIGNATURE DRAINAGE NOTE: Drainage and irrigation for planters and pots, by others, unless otherwise noted. 1111111111111111111111111 58 F.O. BOX 1504 _ IE 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tihf r1 -t'v 4QWA BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:-- 13-00000849 Property Address: 58298 ARACENA APN: — 764-200-999-37 -316812- Application description: POOL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 27000 Applic nt:� Architect or E ineer ------------------ UCEdSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1, m licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business nd Professionals Code, and my License is in full force and effect. License�Glas C8, 10, 27, 2 � License No.: 656128 r (' -7_ _--- - --� Date: �J �J Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by , any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 D SPECTIONS (760) 777-7153 d fo110 e: 7/11/13 Owner: U T D DEVELOPMENT JUL 5 2013 81570 CARBONERIS LA QUINTA,' CA 2253 C17YOF Fpy #Vcx QUINTA Contractor: TESERRA P.O. BOX 1280 COACHELLA, CA 92236 (760)398-9222 Lic. No.: 656128 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor _ Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy num ar Carrier EVEREST NATL IN olic Number 7600006481131 _ I certify that, in the performance f the ork for which this permit is issued, I shall not employ any person in any manner so as be me subject to the workers' compensation laws of California, and gree that, if I should beco subject to the workers' compensation provisions of Section 37 of the Labor Code, I s forthwith comply with those provisions. Date: f/Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application/infor d void if work is not commenced within 180 days from date of issuance of suchvol of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the aion is correct. I agree to comply with all city and county ordinances and state laws relating to buildin, and hereby authorize representatives of this county t ant upon the above-mentioned property fpurposes. Date: ✓'1Signature (Applicant or Agent): Application Number . . . . . 13-00000849 Permit . . . . ELECTRICAL 2013 Additional desc . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date . . . . Valuation . . 0 Expiration Date 1/07/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 ---------------------------------------------------------------------------- 23.83 Permit . . . POOL 2013 Additional desc . Permit Fee . . . . 178.75 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/07/14 Qty Unit Charge Per Extension 1.00 178.7500 EA MISC POOL/SPA ---------------------------------------------------------------------------- 178.75 Permit . . . PLUMBING 2013 Additional desc . Permit Fee . . . . 11.92 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/07/14 Qty Unit Charge Per Extension 1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS 11.92 ---------------------------------------------------------------------------- Special Notes and Comments POOL & SPA, BBQ, FIREPIT,178 IN FT OF 2" POLYPROPELINE GAS LINE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2010 CALIFORNIA BUILDING CODE., -----------------=----------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, POOL 97.24 Fee summary Charged Paid Credited ----------------- ----- - ---- ---------- ---------- ---------- Due Permit Fee Total 214.50 .00 .00 214.50 Plan Check Total .00 .00 .00 .00 Other Fee Total 98.24 .00 .00 98.24 Grand Total 312.74 .00 .00 312.74 LQPERMIT Bin # City of La Quinta Building &r Safety Division Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit #P.O. Project Address: S S 2 $ g Owner's Name:AJDA UJS A. P. Number: Address: J 00 Z 98 '49AC';Er41+ Legal Description: City, ST, Zip: Z_/4- �,JT,e}CA 9ZZS Contractor• Telephone: Address: 6 /'00� 0O l� S y Project Description: O L� City, ST, Zip: �A' Z�L3 C a , Telephone: v 3 g 222 <> > :':<:::.>.>.:>::.>:;:; :>>.:::»::>;> <: ;>.>:.:vs: L D C"'P� ' EC, "VT- r State Lic. #: I ZOO City Lic. Arch., Engr., Designer: Address: City,, ST, Zip: TeleP Telephone: '` ji: cY•• Construction n Type:P Occupancy: ns State Lic. #: Pro ect type circle one)C New Alter Repairair DemoAdd'n Name of Contact Person: Sq. Ft.: #Stories: # Units: Telephone # of Contact Person: C O Z S Q 2--5 18 Estimated Value of Project: O Q'Q APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed; ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsrssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Datof a is ue School Fees FOP rphIST:121 Ir— x[a Total Permit Fees DATE gY 0 l * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD RAISED BOND BEAMT +18"/+24'7+30"WI1 H ACIU * NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD WASH FINISH COLO ED CONCRETE CAP AND * PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY TILE VENEER FACE, HREE ABS 1'-6" WIDE PL SHEER DESCENTS ITH DEDICATED PUMP AND PLUMBING TANNING SHELF AT WITH TWO UMBRELI 12" WATER DEPTH IA SLEEVES ACID WASI FINISH COLORED CONCRETEI DECKING i I 178'- 2" POLYPROPYLENE GAS PIPE I POOL EQUIPMENT 50 AMP SUBPANEL WITH 30" CLEARANCE AT FRONT AND SIDE POOL EQUIPMENT: 400,000 BTU HEATER *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED =CTRIC CONDUIT MAIN HOUSE 200 AMP 14ILECTRICAL PANEL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATERS /PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FACTOR 'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY, FIELD LAYOUT WILL VARY 166'-10" 191 19 M-8 w 3'- -' 11 +30." +24" 3'-0" WD 12" USS 11'-3" GAS — G — GAS — GAS — iPB POOL NTH TILE WATERLINE AND PEBBLE TEC FINISH I V V L n%c urn V 1 r111 vi Iry 11111-L W AMI 1 �— ASME / ANIN APPROVED -- - ---- -RAISED SPA AT +12" WITH ACID WASH FINISH COLORED CONCRETE CAP TWO 1'-8" WIDE CONCEALED TILE LIP SPILLWAYS AND TILE VENEER FACE, 6 JETS AT ALTERNATE HEIGHTS SPA AQUA STAR CHANNEL DRAIN ` - - ASME/ANSI APPROVED ---- PL +18.. 11+1y" ' PB 3'-0"I WD — GAS — GAS — GA4N--- GAS — GAS PB Em 3'-7" SB. FIREPIT AT +9" WITH ACID WASH FINISH COLORED CONCRETE CAP AND TILE VENEER FACE GAS PB GRANITE COUNTERTOP WITH 3" DROP EDGE AT +36" WITH 30" ALFRESCO BARBECUE, 30" STAINLESS STEEL SINGLE DOOR/DOUBLE DRAWER COMBO, FLEX LIGHT, STUCCO EXTERIOR TO MATCH HOUSE 166'-8" 55,$. ARArl=f 111 . PRE FABRICATED FOUNTAIN WITH SUBMERSIBLE PUMP, COBBLE OVERLAY, INTERMATIC TIME CLOCK EXISTING WALKWAY TO REMAIN SAFETY FEATURES: * ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETINIG CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) ELECTRICAL: EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINA'i E VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. 2131 ❑ CALIFORNIA BUILDING CODE (BASED ON2006IBC) 20 1 ❑ CALIFORNIA MECHANICAL CODE (BASED ON 2006 UMC) 20 1 ❑ CALIFORNIA PLUMBING CODE (BASED ON 2009UPC) -rm...utr 20 1 ❑ CALIFORNIA ELECTRICAL CODE (BASED ON 2006 NEC) 20 1 ❑ CALIFORNIA ENERGY EFFICIENCY STANDARDS GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED CONSTRUCTION AUTHORIZATION SALES 11 FIELD DIG PRE-GUNITE UNDERGROUND MASONRY DECK PRE -PEBBLE SPECIFICATIONS TYPE GUNITE SIZE 40'-6" X SURFACE AREA OF POOL ONLY 442 SQ.FT. PERIMETER 119 LN.FT. DEPTHS MIN. 3'-0" MAX POOL & SPA COMBINED 505 SQ.FT.1130 LN.FT. SPA SPECIFICATIONS TI LE SIZE 8'-0" X 6'-0" SQ. FT. 48 LN. FT. 28 TILE TYPE WATERLINE SPA DAM WALL WIDTH TILE TRIM NO. OF JETS QUARTER ROUND LIGHT R.B.B. TILE RAISED SPA AT SPILLWAY TYPE SPECIAL NOTES DECKING EXCAVATION / SQ. FT. 1419 MET. STEEL TYPE FINISH ACCESS FROM EXPANSION JOINTS ELEVATION CANTILEVER DEEP END RAMP DECK DRAINS LOVE SEAT DECCO DRAIN CONCRETE REMOVAL —LOADS CURB CORE SOD REMOVAL LOADS STEPS TREE REMOVAL BY STEP FACE IRRIGATION REMOVAL BY TILE BASE IRRIGATION REPAIR SAND AND VISQUEEN 6" R.B.B. RIBBONS 12" R.B.B. FT4 MOW STRIP 18" R.B.B_ FT 24" R.B.B. 30" R.B.B. TAN SHELF DEPTH ROCK POCKETS MASONRY COPING TYPE CENTERS R.B.B. FACING SPILLWAY TYPE SIZE PLUMBING STEPS FILTER SIZE PROP. EXT. WALLS POOL PUMP SIZE PLANTER WALL BOOSTER PUMP SIZE RETAINING WALLS ADDL PUMP SIZE EQUIP. WALLSFIREPIT ADDL PUMP SIZE HEATER SIZE TIME CLOCK SUB PANEL — ADDL OUTLETS SKIMMER TYPE FILL LINE PEBBLE / PLASTER GAS LINE STUBS LIGHTS POOL LIGHTS SPA FOUNTAINS / SPRAYHEADS ROLLED BOND BEAM SHEER DESCENTS BEHIND SPA LIGHTS IN POOL IN SPA EYEBALLS - STUB SET EQUIPMENT FEN CIN G MISC FENCE TYPE PLUMBING SIZE HEIGHT GATE GUN ITE GATE REVERSAL DEEP END RAMP REMOVE & REHANG EXTEND 2nd STEP LOVESEAT SPILLWAY TYPE EST. START CANTILEVER EST. COMPLETION COPING OTHER R.B.B. - SEE STEEL OWNER RESPONSIBILITIES OWNER TO: (1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS — DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. SIGNATURE(S) DATE SWIMMING POOL PLAN FOR: NAME ANDALUSIA LOT B-37 STREET 58-298 ARACENA JOB ADDRESSANDALUSIA C.C. ICITY LA QUINTA PHONE OFFICE RES LOT B-37 TRACT PAGE BOOK MAP BOOK PAGE NO. ICITY MAIL ADDRESS CONSTRUCTION OFFICE PHONE NO, SCALE DATE DESIGNED BY PROJECT MGR. CHECKED BY F3 1 ' 07-03-13 JT. PAUL Y. JOB# REVISIONS DATE: I f ©ICITY OF LA QUINTA �I = . ' ; FOR CONSTRU'CTION- �I r�> M w ©I � I SELECTIONS STONE TILE BOULDERS DECK COLOR JAN DY PEBB/PLAS SIGNATURE DRAINAGE NOTE: Drainage and irrigation for planters and pots, by others, unless otherwise noted.