Loading...
13-0979 (RPL)58306 Aracena IIIIIII VIII III VIII (III 62 IE P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00000979 Property Address: 58306 ARACENA APN: 764-200-999-38 -316812- Application description: POOL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 28000 c&ht 4 4 Q" Applicant: Architect or Engineer: OLOR14A _ 'Al /vL BUILDING & SAFETY DEPARTMENT BUILDING PERMIT -------------------- ---------------------------- LICEN D CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I a' licensed under provisions of Chapter 9 (commencing with Section 7000) Division 3 of the Business d Professionals Code, and my License is in full force and effect. License Class C , 10 , 27, 2 License IJo.: 656128 mate: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/07/13 Owner: ANDALUSIA LOT B-38 58306 ARACENA LA QUINTA, CA 92253 L% Contractor: AUG 0 9 2013 TESERRA P.O. BOX 280 QVI iA COACHELLA`Q F (760)398- 222 .,,jv4CFnFP Lic. No.: 6128 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is G- issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers'- compensation insurance carrier and policy number ar . Carrier EVEREST NATL IN Poli ' umber 7600006481131 _ I certify that, in the performance of t ork for which this permit is issued, I shall not employ any person in any manner so as to b e subject to the workers' compensation laws of California, an agr a that, if I should beco subject to the workers' compensation provisions of Section 0 f the Labor Code, I sha rthwith comply with those provisions. Date: Applicant: f ' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, o cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abov in rmation is correct. I agree to comply with all city and county ordinances and state laws relating to building co ruction, and hereby authorize representatives of this count o e r upon the above-mentioned property for ' ection purposes. bate: 7 7 Signature (Applicant or Agent): C. Application Number . . . . . 13-00000979 Permit- POOL 2013 Additional desc . . Permit Fee 178.75 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/03/14 Qty Unit Charge Per Extension 1.00 178.7500 EA MISC POOL/SPA ---------------------------------------------------------------------------- 178.75 Permit . . . . . ELECTRICAL 2013 Additional desc . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/03/14. Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 ---------------------------------------------------------------------------- 23.83 Permit . . . PLUMBING 2013 Additional desc . Permit Fee . . . . 11_.92 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/03/14 Qty Unit Charge Per Extension 1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS 11.92 ---------------------------------------------------------------------------- Special Notes and Comments NEW POOL, SPA, FIRE PIT, BBQ AND FIREPIT, 182 L.F. OF 2 INCH GAS PIPING. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2010 CALIFORNIA BUILDING CODE.INSTALL NEW POOL, SPA, BAR-B-QUE AND FIRE PIT WITH 182 L.F. OF 2 INCH GAS LINE. ---------------------------------------------------------------------------- Other Fees• . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, POOL 97.24 Fee summary Charged Paid Credited --------------------------------------------------------- Due .Permit Fee Total 214.50 .00 .00 214.50 LQPERMIT Application Number . . . . . 13-00000979 Plan Check Total .00 00 .00 .00 Other Fee Total 98.24 .00 .00 98.24 Grand Total 312.74 .00 .00 312.74 LQPERMIT ., r- , r- \ / r. n Bin # jf City of La Quin LQ Building Br Safety Division AUG 12013 P.O. Box 1504, 78-495 Calle Tanapico La Quinta, CA 92253 - (760) 777-7012 CITY OF LA QUINTA Building Permit Application and TraCVgkMWY DEVELO"OE Permit # Project Address: S g 3 O (a2A r Owner's Name: 41DA 1,U 51 A. P. Number: Address: S 8 3 p 6 R. Ct�-� Legal Description: City, ST, Zip: 1-4 j , ,v Ch 3 Contractor: 2 Telephone: ;:;«:::";;: >:.;:<;,w::< ::•; Address: 6 6 /0 Q Project Description: �� City, ST, Zip: L 9Z 2-3 C zs z» Telephone: .::.."::::::., .. O Z Z Z 9 2 L �E State Lic. # : (, / 2 8 City Lic. #; L� �— 7 Arch., Engr., Designer: Address: 00 L City., ST, Zip: Telephone: nstruction Type: Occupancy:Co State Lic #• Project t7Pa circle on Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 7CO Z S-0 2,3 18 Estimated Value of Project: ).000 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted D -k Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for correctionissue f 11113 Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees A I 4 DEPT. Total Permit Fees FOR CONSTRUCTION DAA— _.._ _-- BY�/I * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD * NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD * PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY THREE RAISED PLINTHS AT +18" WITH WASH FINISH COLORED CONCRETE CAP, THREE SPILLING POTS, TILE VENEER FACE AND BACK SIDE TANNING SHELF AT 12" WATER DEPTH WITH ONE UMBRELLA SLEEVE FIREPIT AT +9" WITH WASH FINISH COLORED CONCRETE CAP AND TILE VENEER FACE GRANITE COUNTERTOP AT +36" WITH ALX2-30 30" ALFRESCO BARBECUE, 30" STAINLESS STEEL SINGLE DOOR/DOUBLE DRAWER COMBO, FLEX LIGHT, STUCCO AND PAINT EXTERIOR TO MATCH HOUSE Monolith Ftn Description Technical Specs • height: 59 • width: 321n. • depth: 32 in. • weight: 388 lbs. • color shown: sierra • material: glass fiber reinforced concrete INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL PRE FABRICATED FOUNTAIN WITH SUBMERSIBLE PUMP, COBBLE OVERLAY, INTERMATIC TIME CLOCK POOL HEATERS /PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY,: FIELD LAYOUT WILL VARY 212 SQ.FT. POOL AREA WASH FINISH COPING/ CAPS 849 SQ.FT. POOL AREA CAMBRIDGE PAVER DECKING RAISED BOND BEAM AT +12" WITH WASH FINISH COLORED CONCRETE CAP, TILE VENEER FACE AND BACK SIDE ARACENA Ivor &A3LASME OOL AQUA STAR CHANNLEL /ANSI APPROVED (/0.4f 1"110) 3G 14'APA%&7 SPA AQUA STAR CHANNEL DRAIN ASME/ANSI APPROVED SPA AT 0" WITH TILE DAM WALL CAMBRIDGE COBBLE UNTUMBLED BRICK PAVER DECKING SAND SET OVER 4" OF COMPACTED ROAD BASE AND 1" OF BEDDING SAND, POLYMERIC SAND GROUT, MUD SET PAVER SOLDIER COURSE 182'- 2" POLYPROPYLENE GAS PIPE ( GAS METER TO FIREPIT AND BARBECUE) POOL EQUIPMENT 50 AMP SUBPANEL WITH 30" CLEARANCE AT FRONT AND SIDE POOL EQUIPMENT: 400,000 BTU HEATER *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED ELECTRIC CONDUIT 22'- 12" POLYPROPYLENE GAS PIPE ( GAS METER TO HEATER) MAIN HOUSE 200 AMP ELECTRICAL PANEL SAFETY FEATURES: * ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) I ELECTRICAL: I EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. 20 1 ❑ CALIFORNIA BUILDING CODE (BASED ON 2006113C) 201 O CALIFORNIA MECHANICAL CODE (BASED ON 2006 UMC) 20 1 O CALIFORNIA PLUMBING CODE (BASEDON2009UPC) TITLE 21, P.1 20 1 ❑ CALIFORNIA ELECTRICAL CODE (BASED ON 2006 NEC) 20 1 ❑ CALIFORNIA ENERGY EFFICIENCY STANDARDS GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IM AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONITACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED CONSTRUCTION AUTHORIZATION DI G PRE-GUNITE UNDERGROUND MASONRY DECK PRE -PEBBLE II SALES II FIELD I SPECIFICATIONS TYPE GUNITE SIZE 40'-0" X SURFACE AREA OF POOL ONLY 418 SQ. FT. PERIMETER 107 LN.FT. DEPTHS MIN. T-0" MAX POOL & SPA COMBINED 474 SQ.FT.1123 LN FT SPA SPECIFICATIONS TI LE SIZE =x 7'-0" SQ. FT. 49 LN. FT. 28 TILE TYPE WATERLINE SPA DAM WALL WIDTH TILE TRIM NO. OF JETS QUARTER ROUND LIGHT R.B.B. TILE RAISED SPA AT SPILLWAY TYPE ADDL OUTLETS SPECIAL NOTES DECKING sQ. FT. SEE NOTE FINISH EXPANSION JOINTS EXCAVATION / STEEL TYPE ACCESS FROM ELEVATION CANTILEVER DEEP END RAMP DECK DRAINS LOVE SEAT DECCO DRAIN CONCRETE REMOVAL LOADS CURB CORE SOD REMOVAL LOADS STEPS TREE REMOVAL BY STEP FACE IRRIGATION REMOVAL BY TILE BASE IRRIGATION REPAIR SAND AND VISQUEEN 6" R.B.B. ET RIBBONS 12" R.B.B. FT, MOW STRIP 18" R.B.B. 24" R.B.B. FT 30" R.B.B. FT. TAN SHELF DEPTH MASONRY ROCK POCKETS PLUMBING FILTER SIZE POOL PUMP SIZE BOOSTER PUMP SIZE ADDL PUMP SIZE ADDL PUMP SIZE HEATER SIZE TIME CLOCK SUB PANEL ADDL OUTLETS SKIMMER TYPE FILL LINE GAS LINE STUE FOUNTAINS / SPRAYHEADS_ SHEER DESCENTS LIGHTS IN POOL STUB SET EQUIPMENT PLUMBING SIZE GUNITE DEEP END RAMP_ EXTEND 2nd STEP LOVESEAT SPILLWAY TYPE _ CANTILEVER COPING R.B.B. - SEE STEEL IN SPA COPING TYPE_ R.B.B. FACING SPILLWAY TYPE STEPS PROP. EXT. WALLS PLANTER WALL RETAINING WALLS_ EQUIP. WALLS_ FIREPIT_ SIZE PEBBLE / PLASTER LIGHTS POOL LIGHTS SPA ROLLED BOND BEAM BEHIND SPA FENCING FENCE TYPE HEIGHT GATE GATE REVERSAL REMOVE & REHANG EST. START €V. EOMPL€TION OTHER OWNER RESPONSIBILITIES OWNER TO: (1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA - (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS - DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. SIGNATURE(S) DATE SWIMMING POOL PLAN FOR: NAME ANDALUSIA LOT B38 STREET 58306 ARACENA JOBADDRESSANDALUSIA C.C.CITY LAQUINTA PHONE OFFICE RES LOT B-38 TRACT PAGE BOOK MAP BOOK PAGE NO. ICITY MAIL ADDRESS CONSTRUCTION OFFICE PHONE NO. SCALE DATE DESIGNED BY PROJECT MGR. CHECKED BY 811= 1 I 07-31-13 JT. PAUL Y. JOB # REVISIONS SELECTIONS DATE STONE TILE BOULDERS BUILDING & SA iVT',1A DECK COLORROVC JAN DY CCr10N PEBB/PLAS =--_BY 7. SIGNATURE SES DRAINAGE NOTE: Drainage and irrigation for planters and pots, by others, unless otherwise noted. in ka In mN N D N� QmCO U �N Qto tD Jin W '0 IXo QIaiZ O W 0NU3 INZ NOIII U Wa) - QMU 0O O� -� t0 OI a L 0� D RECEIVED AUG O 12013 CITY OF LA QU TA MMUNITY DEVEI.0 PMENT 00 �-I 0 Q