BRES2014-114479731 Arnold Palmer ! IIIIIIIIIIIIIIIIIIIIIIIII 72 4 E - -- 78-495 CALLE TAMPICO VOICE(760)777-7125 LA QUINTA,CALIFORNIA 92253 FAX(760)777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS(760)777-7153 BUILDING PERMIT Date: 2/18/2015 Application Number: BRES2014-1144 Owner: Property Address: 79731 ARNOLD PALMER RUSS MOORE APN: 775241037 79731 ARNOLD PALMER Application Description: 571 SF CASITA ADDITION LA QUINTA,CA 92253 Property Zoning: =—' Application Valuation: $60,000.00 LCIJ L C=3 o _a Applicant: Contractor: N 2 W ROBERT PITCHFORD D&T REMODELING INC o4' o 77622 COUNTRY CLUB STE.D 44630 FRANKLIN COURT no o" co o PALM DESERT,CA 92211 LA QUINTA,CA 92253 d L LJ LL z (760)218-6414 Llc.No.:997936 z -----------------------------------------------'------------=--------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under.penalty of perjury one of the following declarations: 9(commencing with Section 7000)of Division 3 of the Business and rofessions Code, I have and will maintain a certificate of consent to self-insure for workers' and my License is in full force and effect. compensation,as provided for by Section 3700 of the Labor Code,for the performance License Class: License No.:997936 J A-\ of t k for which this permit is issued. I have and will maintain workers'compensation insurance,as required by Date: Contractor: Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. My workers'compensation insurance carrier and policy number are: OWNER-BUILDER DECLARATION Carrier:_ Policy Number:_ I hereby affirm under penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued,I License Law for the following reason(Sec.7031.5,Business and Professions Code:Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct,alter,improve,demolish,or repair compensation laws of California,and agree that,if I should become subject to the any structure,prior to its issuance,also requires,the applicant for the permit to file a workers'compensation provisions of Section 3700 of a Labor Cod ,I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the comply wit those rovisions. Contractor's State License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt therefrom and the Date: Applicant: basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING:FAILURE TO SECURE WORKERS'COMPEPUTION COVERAGE IS UNLAWFUL, ($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO (_)I,as owner of the property,or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS($100,000). IN ADDITION TO THE COST OF compensation,will do the work,and the structure is not intended or offered for sale. COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, (Sec.7044,Business and Professions C6dd,>The Contractors'State License Law does not INTEREST,AND ATTORNEY'S FEES. apply to an owner of propertXwho builds-or improves thereon,and who does.the work himself or herselfthrough his or her own employees,provide', that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If,however,the buildinXi improvement is sold IMPORTANT:Application is hereby made to the Building Official for a permit subject to within one year of completion,the owner-builder will have the burden of proving that the conditions and restrictions set forth on this application. he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made,each person at whose (_)I,as owner of the property,am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit to construct the project. (Sec.7044,Business and Professions Code:The Contractors' issued as a result of this application,the owner,and the applicant, each agrees to,and State License Law does not apply to an owner of property who builds or improves shall defend,indemnify and hold harmless the City of La Quinta,its officers,agents,and thereon,and who contracts for the projects with_a'contractor(s)licensed pursuant to employees for any act or omission related to the work being performed under or the Contractors'State License Law.). following issuance of this permit. (_)I am exempt under Sec. .B.&P.C.for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,or cessation of work for 180 days will subject permit to cancellation. Date: Owner: I certify that I have read this application and state that the above information is correct. CONSTRUCTION LENDING AGENCY I agree to comply with all city and county ordinances and state laws relating to building I hereby affirm under penalty of perjury that there is a construction lending agency for construction,and hereby authorize representatives of this city to a upon he a ove• the performance bf the work for which this permit is issued(Sec.3097,Civ.C.). mentioned ope y for inspection purposes. Lender's Name: Date: Signature(Applicant or Agent): Lender's Address: FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT , PAID PAID DATE ADDITION,EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION,EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY. AMOUNT PAID PAID DATE ADDITION,FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION,FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 PAID BY METHOD RECEIPT# CHECK#• CLTD BY Total Paid forADDITION: $371.73 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK-YES 101-0000-42600 1.5 $105.00 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY Total Paid for BLDG CITY STAFF-PER HOUR: $105.00 $0.00. DESCRIPTION ACCOUNT QTY1 AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $3.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL,FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL,FIRST 1,000SF,PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY Total Paid for ELECTRICAL-NEW CONSTRUCTION: $192.89 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID . PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY I DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY j ' DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $12.09 $0.00 ` PAID BY METHOD RECEIPT# CHECK# CLTD BY I DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY I Total Paid for MECHANICAL: $137.78 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 . 0 $48.36 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE J FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $0.00 4 PAID BY METHOD RECEIPT# CHECK# CLTD BY ' DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE I GAS SYSTEM,1-4 OUTLETS 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY I DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE i I GAS SYSTEM,1-4 OUTLETS PC 101-0000-42600 0 $24.17 $0.00 I PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE ROOF DRAIN 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY I AMOUNT PAID PAID DATE 1 1 ROOF DRAIN PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD ` RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT_ QTY AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY Total Paid for PLUMBING FEES: $176.50 $0.00 DESCRIPTION ACCOUNT QTY AMOUNTPAID PAID DATE SMI-RESIDENTIAL 101-0000-20308 0 $7.80 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $7.80 $0.00 TOTALS: $994.70 $0.00 i r n e w $rE Permit Details PERMIT NUMBER ofLa Quinta : d i i Description:571 SF CASITA ADDITION 3 Type:BUILDING,RESIDENTIAL Subtype:.ADDITION Status:APPROVED Applied:10/23/2014 KHE r Parcel No:775241037 Site Address:79731 ARNOLD PALMER,CA Approved:1/8/2015 AAL 4 Subdivision:TR 21381-1 CM 059/074 SEE ASR MB Block: Lot:3 Issued: 769/41 FOR CM C Lot Sq Ft:0 Building Sq Ft:0 Zoning: Finaled: I Valuation:$60,000.00 Occupancy Type: Construction Type: Expired: No. Buildings:0 No.Stories:0 No. Unites:0 Details: NEW ATTACHED CASITA(571 SF) ? Applied to Approved ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE PHILIP 1UAREZ 1/9/2015 1/9/2015 ROB PITCHFORD CAME AND BROUGHT HOA APPROVAL . LETTER PUT IN FILE PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 11/7/2014 11/7/2014 STRUC RFC 11/6/14 RECEIVED PLAN CHECK COMMENTS STRUCTURAL CONTENT APPROVED PER YOUNG FROM CONSULTANT PHILIP JUAREZ 1/6/2015 1/6/2015 ENGINEERING. RECEIVED PLAN CHECK PICKED UP MARY FASANO 11/17/2014 11/17/2014 PLAN CHECK SUBMITTAL RECEIVED KAY HENSEL 10/23/2014 10/23/2014 RESUBMITTAL KAY HENSEL 12/19/2014 12/19/2014 Printed:Wednesday,February 18,2015 11:39:54 AM 1 of 5 • CRJ LJ SYSTEMS . a ui Q•cy o¢ � L Permit Details PERMIT NUMBER . i i i City of La Quinta SENT TO PLAN CHECK KAY HENSEL 10/23/2014 10/23/2014 STRUC TO YOUNG DUE 11/6 CONSULTANT SENT TO PLAN CHECK KAY HENSEL 12/19/2014 12/19/2014 STRUC TO YOUNG-DUE 1/5/15 CONSULTANT TELEPHONE CALL ARMEN ALTOUNIAN 1/8/2015 1/8/2015 LEFT MESSAGE FOR ROB PITCHFORD.PLANS APPROVED AND READY FOR PICK UP. TELEPHONE CALL JIM JOHNSON 11/7/2014 11/7/2014 CALLED ROB PITCHFORD @ 346-2856.PLANS READY FOR CORRECTIONS,GOT MESSAGE MACHINE CONDITIONS CONTACTS NAME TYPE. NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ROBERT PITCHFORD 77622 COUNTRY CLUB PALM DESERT CA 92211 STE.D CONTRACTOR D&T REMODELING INC 44630 FRANKLIN LA QUINTA CA 92253 COURT OWNER RUSS MOORE 79731 ARNOLD LA QUINTA CA 92253 PALMER FINANCIAL • • • DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT# CHECK# METHOD PAID BY CLTD BY ADDITION,EA 101-0000-42400 0 $62.36 $0.00 ADDITIONAL 500 SF ADDITION,EA 101-0000-42600 0 $17.40 $0.00 ADDITIONAL 500 SF PC ADDITION,FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ADDITION,FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 Total Paid forADDITION: $371.73 $0.00 Printed:Wednesday,February 18,2015 11:39:54 AM 2 of 5 • CRSYS7EMS j"a a q„�yG a� o NUMBERPermit Details PERMIT ,+ may ` i I ' City of La Quinta c e5` DESCRIPTION y ACCOUNT �'- CITY i AMOUNT PAID PAID DATE RECEIPT# _CHECK# ^METHOD PAID BY CLTD BY HOURLY PLAN CHECK- 101-0000-42600 1.5 $105.00 $0.00 YES Total Paid for BLDG CITY STAFF-PER HOUR: $105.00 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $3.00 $0.00 BSA: RESIDENTIAL,FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF RESIDENTIAL,FIRST 101-0000-42600 0 $47.86 $0.00 1,OOOSF,PC Total Paid for ELECTRICAL-NEW CONSTRUCTION: $192.89 $0.00 CONDENSER/COMPRES 101-0000-42402 0 $36.26 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $24.17 $0.00 SOR PC FURNACE 101-0000-42402 0 $36.26 $0.00 FURNACE PC 101-0000-42600 0 $24.17 $0.00 VENT FAN 101-0000-42402 0 $12.09 $0.00 VENT FAN PC 101-0000-42600 0 $4.83 $0.00 Total Paid forMECHANICAL: $137.78 $0.00 FIXTURE/TRAP 101-0000-42401 0 $48.36 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $0.00 GAS SYSTEM,1-4 101-0000-42401 0 $12.09 $0.00. OUTLETS GAS SYSTEM,1-4 101-0000-42600 0 $24.17 $0.00 OUTLETS PC ROOF DRAIN 101-0000-42401 0 $12.09 $0.00 Printed:Wednesday, February 18,2015 11:39:54 AM 3 of 5 R?LJ iJ SYSTEMS DetailsPermit S City of La Quinta BRE&I DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT# CHECK# •METHOD PAID BY CLTD BY ROOF DRAIN PC 101-0000-42600 0 $12.09 $0.00 WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 WATER HEATER/VENT 101-0000-42600 0 $7.25 $0.00 PC Total Paid for PLUMBING FEES: $176.50 $0.00 SMI-RESIDENTIAL 101-0000-20308 1 0 $7.80 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $7.80 $0.00 TOTALS: • $0.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE FINAL" PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE NON-STRUCTURAL ARMEN 10/23/2014 11/6/2014 10/27/2014 REVISIONS REQUIRED CORRECTIONS RFC ALTOUNIAN REQUIRED STRUCTURAL JIM JOHNSON 10/23/2014 11/6/2014 11/7/2014 REVISIONS REQUIRED CORRECTIONS 1ST.STRUC PLAN CHECK CORRECTION REQUIRED NON-STRUCTURAL ARMEN 12/19/2014 1/5/2015 12/22/2014 APPROVED 2ND PLAN CHECK APPROVED ALTOUNIAN STRUCTURAL JOHN 12/19/2014 1/5/2015 12/19/2014 APPROVED 2ND PLAN CHECK STRUC DUE BACK 1/5/15 THOMPSON APPROVED BOND INFORMATION Printed:Wednesday,February 18,2015 11:39:54 AM 4 of 5 ?`? V SYSTEMS 7 • _. a. s w NY 4 w r w« x ii L fu4 ._ t � x# w '3.r`i' se' f _ Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR, ETRAKIT ENABLED DOC 10/27/2014 ARMEN ALTOUNIAN N/S 1ST REVIEW 79-731 ARNOLD 0 COMMENTS.docx PALMER.docx DOC 2/18/2015 STEPHANIE KHATAMI SCHOOL FEE RECEIPT SCHOOL FEE LETTER- 0 BRES2014-1144 BRES2014-1144.pdf Printed:Wednesday,February 18,2015 11:39:54 AM 5 of 5 (r ii IJV SYSTEMS IIIIIIIIIIIIIIIIIIIIIIIII 73 44 0 IE - P.O. BOX 1504 No. 002875 Building 79-731 Avmld LA QUINTA,CALIFORNIA 92253 Address Owner BUILDING: TYPE CONST. Mailing OCC:GRP, Address 7v M.? A.P. Number CityJZip Tel. .. ,fly, _ 92260 .560 Legal Description Contractor G.H. P0101r3 Project Description . Address. P.O. alm 399 City Zip Tel: - rat city State Lic. City &Classif. 275796 Lic.# Sq. Ft. No. No. Dw. ' Arch., Engr., Size Stories - Units Designer New ❑ Add ❑ Alter❑ Repair ❑ Demolition ❑ Address Tel. City Zip State T—bol Wild Sim - Lic.# LICENSED CONTRACTOR'S DECLARATION, I hereby affirmlthat I am licensed under provisions of:Chapter 9(commencing with Section 7000)of Divisioon 3 of the-Business and Professions,Code,.and my license is in full force and effect.. Il .+` f ✓ ter '= `3 " SIGNATURE DATE ' OWNER-BUILDER DECLARATION Estimated ValUatiOn / y / r I hereby affirm that I am exempt from the Contractor's License Law for the following '20;*.00.06 reason: (Sec. 7031.5,Business and Professions Code: Any city or county.which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to PERMIT - AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section.7000) of 'Division 3 of the Business and Professions Code, or thathe is exempt therefrom, and the basis - Plan Chk. De for the alleged exemption. Any violation of Section 7031.5 by'any applicant for a permit Dep.. • subjects the applicant to a civil penalty of not more than five hundred dollars(8500). ' ' ❑I,as owner of the property,or my employees with wages as their sole compensation,will Plan Chk. Bal. 95-22 do the work,and the structure is not intended or offered for sale.(Sec. 7044,Buisness and Const. 146.54Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon-and who does such work himself or through his own employees, Mech. provided that such improvements are not Intended or.offered for sale. If, however, the building , or improvement is sold within one year of completion, the owner-builder will have the burden Electrical proving that he did not build or improve for the purpose of sale.) .. ❑ I,as owner of the property,am exclusively contracting with licensed contractors to con- Plumbing 14.00 struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. 1.44 such projects with a contractor(s)licensed pursuant to the Contractor's License Law.) Grading O 1 am exempt under Sec. . B.&P.C.for this reason Driveway Enc. Date owner Infrastructure WORKERS'COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self-insure, or a certificate of Worker's Compensation Insurance,or a certified copy thereof.(Sec.3800,Labor Code.) _ Policy No. . .Company -+) ❑Copy is filed with the city. ❑Certified copy is hereby furnished. _ TOTAL ! 2%.16 CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS'.COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars (8700) valuation or less.) I certify that in the performance of thg work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers'Compensation Laws of California. Date Owner- NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the Labor Code, you must forthwith Minimum Setback Distances: ' comply with such provisions or this permit shall be deemed revoked. Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued.(Sec.3097,Civil code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE INSPECTOR This is a building permit when properly filled out,signed and validated,and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is-correct. Issued by: Date 2-29—S7 Permit I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of-this city to enter the above- mentioned property for inspection:purposeS-11 -- Validated by: Signature of applicant r r ``` ~ .!' Date e j', 'j Mailing Address Validation: City, State, Zip Ai231 2 3 16 Ck HARD COPY CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO.FT.® $ UNITS 2ND FL. SQ.FT. YARD SPKLR SYSTEM POR. SO.FT.® MOBILEHOME SVC. BAR SINK GAR. SQ.FT.® POWER OUTLET ROOF DRAINS CAR P. SQ.FT. DRAINAGE PIPING WALL SO.FT.® DRINKING FOUNTAIN SQ FT ® URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE:Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE,TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO.FT.®c BATH TUB SQ.FT.®c WATER HEATER MAX.HEATER OUTPUT,B.T.U. SQ.FT.RESID®11/4 c SEWAGE DISPOSAL SQ.FT.GAR®3/ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST.FEE ELECT.FEE SMI FEE PLUMB.FEE STRUCTURE PLUMBING ELECTRICAL HEATING&AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C.UNIT COLL.AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING(ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND.REINF. GAS(ROUGH) METER LOOP HEATING(FINAL) OTHER APPJEOUIP. REINF.STEEL GAS(FINAL) TEMP.POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING LUMBER GR. FINAL INSP. cu.yd. FRAMING FINAL INSP. $ plus x$ =$ ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS. GARDEN WALL FINAL 1111 IIIIIIIII1111IIII 74 I IE 44 P.O. BOX 1504 No. 002565 Building Address ? •- LA QUINTA,CALIFORNIA 92253 ` . 1 'xf[? i t 't y • . _ , Owner BUILDING: TYPE CONST. OCC:GRP. Mailing Address75 ' C.tbtWiVe, A.P. Number City Zip Tel. 92960 Legal Description Contractor Project Description PM VEW PhaiM 3 C lmtl. H=t. and Lal-A - Address P1= 3010 m Sam City Zip Tel. Sam State Lic. City M= 3971 &Classif. 288130 Lic.# 328 Sq. Ft. b57 No. No. Dw. Arch., Engr., Size *Stories - Units Designer New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. City Zip State . . - - Lic.# - LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9(commencing with Section 7000)of ivision 3 of the Business and Professions Code,and my licenseIis in full force and effect. .. - \ ;, . A r; SIGNATURE - `4 - DATE OWNER-BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following tn reason: (Sec... f 7031.5,Business and Professions Code: Any city or county which requires a .G- V.84• permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file,a signed statement that he is licensed pursuant to PERMIT ' AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that:he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permitPlan Chk. Dep. subjects the applicant-to a civil penalty of not more than rive hundred.dollars($500). O I,as owner of the property,or my employees with wages as their sole compensation,will Plan Clik. Bal. ' , do the work,and the structure is not intended or offered for sale.(Sec. 7044,Buisness and Const. $ Q Professions Code: The Contractor's License Law does not apply.to an owner of property who • builds or improves thereon and who does such work himself or through his own employees, Mech. provided that such improvements are not intended or offered for sale. If,.however, the building or improvement is sold within one year of completion, the owner-builder will have the burden Electrical 3+ of proving that he did not build or improve for the purpose of sale.) O I,as owner of the property,am exclusively contracting with licensed contractors to con- Plumbing 148+50 struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. 17.54 such-projects with a contractor(s)licensed pursuant to the Contractor's License Law.) Grading O lam exempt under.Sec. B.&P.C.for this reason Driveway Enc. Date Owner Infrastructure 2,000.00 WORKERS'COMPENSATION DECLARATION I hereby affirm that I"have a certificate of consent to self-insure, or a certificate of Worker's Compensation Insurance,or a certified copy thereof.(Sec.3800,Labor Code.) Policy No. Company ❑Copy is filed with.the city. ❑Certified copy is hereby furnished. _ TOTAL CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS'COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) - I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject*to the Workers'Compensation Laws of California. Date • Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the'Labor Code, you must forthwith Minimum Setback Distances: comply with such provisions or this permit shall be deemed revoked.- Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the ' work for which this permit is issued.(Sec.3097,Civil Code.) Side Setback from Property Line Lender's Name Lender's Address This is a building permit when properly filled out,signed and validated,and is.subject to FINAL DATE INSPECTOR expiration if work thereunder is suspended for 180 days. I certify that I have read this application and stale that the above information is correct. Issued by: Date Permit I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Validated by: Signature of applicant t- Date -r',' Mailing Address Validation: City, State, Zip A 6 3 1 0 .9 10 385548 ft HARD COPY CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ.FT.® $ UNITS 2ND FL. SQ.FT.p YARD SPKLR SYSTEM POR. SO.FT.® MOBILEHOME SVC. BAR SINK GAR. SO.FT.®_ POWER OUTLET ROOF DRAINS CAR P. SQ.FT. DRAINAGE PIPING WALL SQ.FT. DRINKING FOUNTAIN SQ.FT.® URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE:Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ.FT.®c BATH TUB SQ.FT.®c WATER HEATER MAX.HEATER OUTPUT,B.T.U. SO.FT.RESID®11/4 c SEWAGE DISPOSAL SQ.FT.GAR®3/a,- HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST.FEE ELECT.FEE SMI FEE PLUMB.FEE t STRUCTURE PLUMBING ELECTRICAL HEATING&AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C.UNIT COLL.AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING(ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND.REINF. GAS(ROUGH) METER LOOP HEATING(FINAL) OTHER APP./EQUIP. REINF.STEEL GAS(FINAL) TEMP.POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING LUMBER GR. FINAL INSP. cu.yd. FRAMING FINAL INSP. $ plus x$ _$ ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH I N SU LATIONISOUN D FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS. GARDEN WALL FINAL Bin # 3oACity h11 of La Quinta Building et Safety Division Permit # 14,P.O. Box 1504, 78-495 Calle Tampico La Quinw, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: -79 — -7?,,/ : Q (" 'e A P. Number: -*77!57 '24 I % 7 rJ EAdd Legal Description: O -j 9 '�. 21 t't_9(ArContraaor: "�'(j`� Address: Project Description: City, ST, Zip: r � )r-17� Telephone: State Lic. # : City Lic. #: ., Designer:] Address: %'7 6 ZZ� City, ST, Zip: Telephone: 60 Construction Type: Occupancy: State Lic. #: Pro'J ea hype (circle one): New Add'n Altcr Repair Demo Name of Contact Person: FtT•C#4�—ep' `5 Sq. Ft.: Scotties: # Units: Telephone # of Contact Person: %60 67 0 Estimated Value of Project: 60, coo 9 APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Req'd Rec'd TRACKING Plan Sets PERMlT FEES a? Plan Check submitted Structural Coles Item Amount a Reviewed, ready for corrections i I Plan Cbeck Deposit Truss Caics. Called Contact Person i Plan Check Balance Energy Coles, a Plans picked up i n Construction Flood plain plan Plans resubmitted %Z 1`j Mechanical Grading plan 2" Review, ready for correctionsrmus Eteelrieal Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up ILO.A. Approval SALT. Pians resubmitted Grading W HOUSE: - Review, ready for Developercorrections/issue Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr .LP.P. Date of permit issue A School Fees 1D/a3 -91 =-:; �� 2,122 - NIS 1A1'�'R b Total Permit Faes --. I CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES 0 V) RANCHO MIRAGE tZ� Date 2/18/15 La Quinta, CA 92253 INDIAN WELLS ti No. 31715 �� PALM QUINTA (760) 771-8515 �1PINDIO Owner Moore APN # 775-241-037 Address 79731 Arnold Palmer Jurisdiction La Qu:nta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79731 Arnold Palmer 571 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Detached Casita At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the fol owing reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.36 X 571 S.F. or $1,918.56 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Chase Bank - Tracy Norblom Check No. 103892953 Bank Name/Recipient of Certificate Telephone Funding Residential BY Dr. Gary Rutherford Superintendent Fee collected /exemp by S n it rey Payment Recd 'J$0.00 0 $1918.56 'bver:Unde�. r Signature ' a NOTICE: Pursuant to Government Code Section 66020(d)(1), this ill erve to notify you that the 90 -day approval period inwhich•you may protest the fees or other payment identified above will begin to run from the date on ich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting PGA WEST - RESIDENTIAL ASSOCIATION, INC. October 28, 2014 N JP ` �o �Q MENS Mr. Russell Moore, Jr. Gam` bel 160 Encinal Avenue Mv�1 Atherton, CA 94027 God RE: 79-731 Arnold Palmer - Architectural Variance- Casita Page 1 of 2 Dear Mr. Moore, The Architectural Committee has reviewed your Architectural Variance submittal of preliminary plans for a casita addition. The following proposed casita drawings: Sheets L 2, 3 and 4 dated August 26, 2014, prepared by Robert A. Pitchford, were provided. The proposed casita addition is acceptable conceptually, but, prior to starting` production drawings . we need a written confirmation that you are aware there are numerous known and unknown service and utiltty fines routed through this area of the propgty. The homeowner is responsible to locate and have re- routed any service lines and maintain the area serviced in operation. - Tae protect .is not acceptable to proceed until this matter is finalized The property drame including roof drainage will have to also be addressed to assure proper flow and travel to the street from both the rear yard and sided_. The following conditions and/or requirements are pertinent subject to finalizing the utility and drainage issues. 1. 2. 3. 4. 5. Final Dlans must be submitted for review. Submit a copy of the City of La Quinta building department permit and the city stamped plans prior to starting any work.- The ork:The homeowner and contractor are to meet with the Landscape/Irrigation Manager, Bill Bobbitt, and the Maintenance/Lighting Manager, William Aceves, prior to the start of any work. It is the responsibility of the homeowner to locate and mair_tain the operation of the existing irrigation and lighting systems. The HOA is not responsible for verifying property lines, easements and existing utility services. The relocation and/or modification of the existing utilities, electrical, irrigation and drainage :is to be the responsibility of the. homeowner and done to the building industry standards based. on this site and the building codes. .. 6. The owner's contractor to remove any -trees. and: shrubbery while preventing ariy damage to adjacent property:. The owner is 16'replace. the removed landscaping with a design that provides comparable landscape privacy for the neighbor. Please submit a revised landscape plan for review by Bill Bobbitt, Landscape/Irrigation Manager. - 7. 54-320 Southern Hills, La Quinta, California 92253-5665, Telephone 760-771-1234 FAX 760-771-5125 Page 2 of 2 8. The contractor to repair and/or replace any damaged irrigation, landscape, hardscape, lights or street surface to the satisfaction of the HOA. 9. Contractor to observe. allAssociation rules and regulations. All contractor vehicles to park on one side of the street only. 10. The contractor may not stockpile any material, equipment or construction debris in the street. All debris must be cleaned up daily. 11. The street gutters cannot be used for concrete wash out and the contractor is responsible for keeping the gutter clear and free of debris. 12. All site drainage is to be properly engineered and installed to prevent any flooding. 13. The roof tile color and style is to match the existing.. All stucco, trim and finish details to . match existing. 14. The homeowner and the contractor . to .. schedule a meeting with. the. landscape and. irrigation manager and the maintenance manager prior to submitfing a Notice of Completion. 15. Upon completion of the project, the homeowner is required to provide a signed copy of the city inspection card and the Contractor Certification letter (enclosedi. 16. A Maintenance and IndemniU AgLeement shall be signed prior to the -tart of work and reviewed at the completion of the project. Same shall delineate all applicable work, which current and future owners shall be compelled to solely maintain .and/or replace as needed and the document shall be recorded with the County of Riverside and runs with the land. We reserve the right to make a final inspection of this change to make sure that it matches the original request. An approval is based only on the aesthetics of your proposed plan and should not be taken as any certification as to the construction worthiness or structural integrity.of the proposed change. We appreciate your cooperation in submitting this request for approval. If I may be of further assistance, please contact me at the HOA office, (760) 771-1234, Extension 15. Cordially, C Key cGalliard Operations Manager For the Architectural Committee KM/bvf Enc. 1 cc: Architectural Committee YOUNG G. ENGINEERING S e is : v . c e S -?�(�f�l�/ZrU�> f sitC�tj7�b�UJi Letter of Transmittal To: City of La Quinta Today's Date: 1-6-15 78-495 Calle Tampico City Due Date: 1-5-15 La Quinta, CA 92253 Project Address: . 79-731 Arnold Palmer Attn: Kay Plan Check #: BRES 2014-1144 ❑ Your Pickup Descriptions: Revised Structural Plans Revised Struct. Calcs Revised Truss Revised Soils Report Approved Structural Plans Approved Structural Calcs Approved Truss Calcs Approved Soils Report Other: _ onj; If you have any questions, please call. R ,i ITNTA Time =.75 HR r,aiF1 nPMENT This Material Sent f.or: ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other:.❑ By: Kathryn Samuels Palm Desert Office': ® (760) 772-5107 Other: ❑ r Submittal: ® 1St ❑ 4th ' ❑ 2nd ❑ 5th ❑ 3rd ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) Includes: # Of Descriptions: Includes: # Of Copies: . ' Copies: ❑ Structural Plans ® 1 ® 1 Structural Calculations ❑ ❑ Truss Calculations Floor ❑ and Roof ❑ Soils Report ❑ ® 2 Structural Comment List/ ❑ Responses ® 1 - Redlined Structural Plans ❑ ❑ Redlined'Structural Calcs ❑ ❑ Redlined Truss Calcs ❑ ❑ Redlined Soils Reports ❑ Comments: Structural content is aoorovable. ❑ Your Pickup Descriptions: Revised Structural Plans Revised Struct. Calcs Revised Truss Revised Soils Report Approved Structural Plans Approved Structural Calcs Approved Truss Calcs Approved Soils Report Other: _ onj; If you have any questions, please call. R ,i ITNTA Time =.75 HR r,aiF1 nPMENT This Material Sent f.or: ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other:.❑ By: Kathryn Samuels Palm Desert Office': ® (760) 772-5107 Other: ❑ r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CF1 R -PRF -01 Pagel of 8 GENERAL INFORMATION 01 Building Complieswith Computer. Performance` / %'"- 02 This building incorporates features that require field testing and/or verificatior"by a certified HERS rater under: -the supervision of a CEC-approved HERS provider. 01 Project Name Moore Casita 04 05 1 06 07 02 Calculation Description Title 24 Analysis Proposed Compliance Design Margin Percent Improvement 03 Project Location 79-731 Arnold Palmer -52.9% Space Cooling 233.43 04 A City La Quinta 05 Standards Version Compliance 2015 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (650) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 225 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 571 15 Number of Zones 1 16 Slab Area (FT2) 571 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 . Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 37.8% COMPLIANCE RESULTS."^`' 01 Building Complieswith Computer. Performance` / %'"- 02 This building incorporates features that require field testing and/or verificatior"by a certified HERS rater under: -the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Feat6res shown below ENERGY USE SUMMARY 04 05 1 06 07 08 Energy Use Standard (kTDV/ft) Design Proposed Compliance Design Margin Percent Improvement Space Heating 8.37 12.80 -4.43 -52.9% Space Cooling 233.43 230.43 3.00 1.3% IAQ Ventilation 2.79 2.79 0.00 0.0% Water Heating 31.22 26.41 4.81 15.4% Photovoltaic Offset ---- 0.00 0.00 -- Compliance E-4- r n 0 w ��2�7.5��81 272.43 3.38 1.2% BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE) &I bCBY4A;k% Registration Number: 214-N0 CA Building Energy Efficiency Standards - 2013 Residential Compliance REQ® 3 O OCT 2 3 (2014 Registration Date/Time: 2014-10-0801-PY41C)?, i • vPriv Ia HERS Provider: CaiCERTs inc. Report Version - CF1R-09042014-650 COMMUNI T YG �Je:i )RP-v.'I,Report Generated at: 2014-10-08 14:05:15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD ' Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins CF1 R -PRF -01 Page 2 of 8 PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, reclure field verification by a certified HERS Rater. • IAQ mechanical ventilation ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV, energy offset by an on-site renewable energy system. t Reference Energy Use Energy Design Rating MarginPercent Improvement Total Energy (kTDV/f2)*' i' 369.21. 365.83 3.38 0.9% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) r,'ipgl .E' V • a BUILDING - FEATURES INFORMATIONk� ';1... ,' 01 . ^ 02= `' ' ` -i ` z .: 03 �. " _ - „• ,.04 fr 05- 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Moore Casita 571 it 1 3 1 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type - HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Casita Conditioned HVAC 1 casital 571 14 DHW Sys 1 Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 14:05:15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xmi CF1 R -PRF -01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) NE Wall Casita R-21 Wall (W.21:2x6.16) 45 Back 840 40 90 SE Wall Casita R-21 Wall (W.21.2x6.16) 135 Right 500 60.032 90 SW Wall Casita R-21 Wall (W.21.2x6.16) 225 Front 840 0 90 NW Wall Casita' R-21 Wall (W.21.2x6.16) 315 Left 500 116 90 Roof Casita R-38 Roof Attic SE Wall (Right -135) 571 8.0 0.938 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons ; 3 0.1 0.85 No No WINDOWS Ol 02 4 i� i x f 03 Y - V ` 7..:. 1. `' o-' 04' 1 -) r 65 >� - 06 07 08 09 10 Name Type y _� ys� ►•c # � Y.. k Width(ft rHeight. w,!Surface (Orientation`Azimuth), ' �.L" - �,),. f (ft):'• , .-^ -MArea Multip ier (ft2) U -factor SHGC Exterior Shading 2x5 Window "' ' "- IiNE Wall (Back -45) " - - - - 1 10.0 0.51 0.29 2x5 2 Window r "' NE Wall (Back -45) - - 1 10.0 0.51 0.29 5x4 Window !NE Wall (Back -45) -- -- 1 20.0 0.51 0.29 8x8 Window SE Wall (Right -135) 8.0 8.0 0.938 60.0 0.51 0.29 8x4 Window NW Wall (Left -315) 8.0 4.0 1 32.0 0.51 0.29 6x8 Window NW Wall (Left -315) 1 6.0 8.0 1 48.0 0.51 0.29 6x6 Window NW Wall (Left -315) - - - 1 36.0 0.51 0.29 DOORS 01 02 03 04 Name Side of Building Area (ft) U -factor solid Door SW Wall 20.1 0.50 Registration Number: 214-N0113564A-000000000-0000 Registration Date/Time: 2014-10-0814:17:41 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 HERS Provider: r CaICERTS inc. Report Generated at: 2014-10-08 14:05:15 PI CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title.24 Analysis Input File, Name: Moore Casita-Pitchford-14.xml CFI R -PRF -01 Page 4 of 8 OVERHANGS AND FINS 01 02 03 04 05' 06 07 08 09 10 . 11 12 13 14 05 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up fixR fi 01 6 6 n n n n 0 0 0 0 n 8x4 6 0.1 6 6 0 0 0 0 0 0 0 0 0 6x8 6 0.1 6 6 0 0 0 0 0 0 1 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name. Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 2x4 Top Chord of Cavity/ Frame: no insul. /2x4 Top Chrd .` Roof Truss @ 24 in.. Roof Deck: Wood Siding/sheathing/decking Attic Roof Coris Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board ,! �. &-i16-g. ,x Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic Ceilings (below attic) ry f It Wood Framed Ceiling 2x4 @ 16 m iO.C: „� R 38 Over Floor Joists: R-28.9 insul. i d�;' i f' } ;: �! f • _ �,, ` t• •+. glnside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 . R-21 Wall (W.21.2x6.16) Exterior Walls *•' `N:l Wood Framed Wall 2x6 @ 16 in: O'. C. •' R'21 Exterior Finish: Wood Siding/sheathing/decking r SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Covered Slab Casita 571 126 None 0.8 No BUILDING ENVELOPE HERS VERIFICATION 01. 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa 'Not Required Not Required Not Required -- WATER HEATING SYSTEMS , 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Pipe Insulation, All Lines 1 0.0% Registration Number: 214-N0113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -09042014-650 HERS Provider: CaICERTS inc. Report Generated at: 2014-10-08 14:05:15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CF1 R -PRF -01 Page 5 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a SplitAirCond -Split air conditioning n/a HVAC SYSTEMS 01 02 03 04 05 06 07 ` —Heating System / - ' f.-`CCooling System Name System Type EER SEER �,,� ! A / % f HERS Verification Distribution SplitAirCond -Split air conditioning Floor Area Name System%Type Name Ducted R �, NameDucted System Fan System Served 1 -hers -cool Cooling j ' Air Distribution HVAC 1 casital Other Heating and Cooling System~ Heating Component 1 Yes'Component 1 Yes System 1 HVAC Fan 1 571 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06. 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond -Split air conditioning 13.1 17.7 No No Cooling Component system 1 -hers -cool Registration Number: 214-N0113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 14:05:15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xmi CFI R -PRF -01 Page 6 of 8 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 IAQ Watts/CFM Verified Duct Design Name Duct Leakage Verification Supply Duct Verified Duct Location Return Supply Air Distribution System 1 -hers -dist Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution conditioned space System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 06 Name IAQ CFM IAQ Watts/CFM Verified Duct Design Name Duct Leakage Verification I Duct Leakage_Target (%) 1 i Verified Duct Location Return Supply Air Distribution System 1 -hers -dist Required .. 1p, 6A f / �.^ Not Required Not Required Not Required , +moi I }_a! s_ '_ 't. ' (L '^ HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 35.71 0.25 Default 0 Required Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 14:05:15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Moore Casita Calculation. Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CFI R -PRF -01 Page 7 of 8 COOLING VENTILATION 01 02 03 04 05 Name Cooling Vent. CFM Cooling Vent Watts/CFM Number of Fans HERS Verification WH Fan 1 61 0.52459 1 Required leo Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 14:05:15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 'Page 8 of 8 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xmi DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2014-10-08 14:10:56 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business,and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.. 2. - I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 1 3. The building design features or system design features identifiedon.-this-Certificate of Compliance are -consistent -with the information provided on other applicable compliance documents, worksheets, calculations, plans and p cificafions submitted•to the enforcement agency for appFoval with this building permit application. Responsible Designer Name: .j � fir• `` ;? J�t? Responsible Designer Signature: Pitchford_�`if=� Robert Company: T- 'Date Signed:" Robert A. Pitchford Design & Drafting 2014-10-08 14:17:41 Address: t License: 77-622 Country Club Drive, Suite O na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-2856 , I Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document,.and in noway implies Registration Provider responsibility for the accuracy of the 'information. . Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014=650 Report Generated at: 2014-10-08 14:05:15 i COPY BUILDING ENERGY ANALYSIS REPORT PROJECT:* Moore Residence Casita 79-731 Arnold Palmer La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club STE 0 Palm Desert, CA 92211 .(760) 346-2856 Report Prepared by:, Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Pa[PQ,D-e K OCT 23 2014 CI 1-1 . OF LA QUIN-r,'A CITY OF LA QUINTA COMMUNITY. DEVELOPNEN I- BUILDING &SAFETY DEPT. APPROVED Job Number: FOR CONSTRUCTION DATE_L/_J5ZKBy Date: 10/8/201.4 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I EnergyPro 6.3 by EnergySo ft User Number.- 6712 ID: I I CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CFOF-01 Pagel of 8 GENERAL INFORMATION 01 Building Complies with Computer Performance' 02 This building incorporates features that require field testing and/oar verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 01 Project Name Moore Casita 04 05 02 Calculation Description Title 24 Analysis Energy Use (kTDV/ft) Standards Design 03 Project Location 79-731 Arnold Palmer Space Heating8 37 04 A City La Quinta 05 Standards Version Compliance 2015 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (650) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 225 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 571 15 �� Number of Zones 1 16 Slab Area (FTZ) 571 17( Number of Stories 1 18 Addition Cond. Floor Area NA Natural Natural Gas Available Yes 20 Addition Slab Area (FTZ) NA JAV1 Glazing Percentage (%) 37.8% A`W COMPLIANCE RESULTS t6 v 01 Building Complies with Computer Performance' 02 This building incorporates features that require field testing and/oar verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown tielow �WNERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft) Standards Design Proposed Compliance Design Margin Percent Improvement Space Heating8 37 12.80 4.43 -52.9% Space Cooling a2,33.43 230.43 3.00 1.3% IAQ Ventilation 2.79 2.79 0.00 0.0% Water Heating 31.22 26.41 4.81 15.4% Photovoltaic Offset Compliance Energy Total's nn ` -- 0.00 0.00 — 275.81 272.43 3.38 1.2% Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Registration Date/Tis eDATE BY Report Version - CF HERS Provider: Report Generated at: 2014-10-08 14:05:09 CERTIF OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins PROJECT HERS FEATURES CFOF-01 . Page 2 of 8 The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, require field verification by a certified HERS Rater. • IAQ mechanical ventilation ENERGY DESIGN RATING �W This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic a_"Ppliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy'Design Rating Margin Percent Improvement Total Energy (kTDV/f2)' 369.21 365.83 3.38 0.9% 71 includes calculated Appliances and Miscellaneous Energy Use (AMEU) �® BUILDING - FEATURES INFORMATION v 01 02 03 1•1 AM 04 05 06 07 Zone Name Zone Type Number of Dwelling Zone Floor Area (ft2) Avg. Ceiling Height Number of Ventilation Number of Water Project Name Conditioned Floor Area (sft) Units *6111, Number of Bedrooms Number of Zones Cooling Systems Heating Systems Moore Casita 571 vA 3 1 1 1 . ►7% ZONE INFORMATION �X 01 02 ��v 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Casita Conditioned HVAC 1 casital 571 14 DHW Sys 1 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 14:05:09 144 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE &*OD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CFIOF-01 _ Page 3 of 8 OPAQUE SURFACES 01 02 03 . M Name Side of Building Area (ft2) U -factor solid Door ^s�� SW Wall 20.1 0.50 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft2) Tilt(deg) NE Wall Casita R-21 Wall (W.21.2x6.16) 45 Back 840 40 90 SE Wall Casita R-21 Wall (W21.2x6.16) 135 Right 500 60.032 90 SW Wall Casita R-21 Wall (W.21.2x6.16) 225 Front 840 0 90 NW Wall Casita R-21 Wall (W.21.2x6.16) 315 Left 500 116 90 Roof Casita R-38 Roof Attic 8x8 Window 571 8.0 8.0 ATTIC 01 02 03j�04 05 06 07 Name Construction Roof Rise Roof'Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 No No e: WINDOWS 01 02 03 . M Name Side of Building Area (ft2) U -factor solid Door ^s�� SW Wall 20.1 0.50 01 02 03 in 04 05 06 07 08 09 10 Name Type Surface (Orientation-Azimut0:0 Width(ft ) Height (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading 2x5 Window NE Wall (Back -45) - -- 1 10.0 0.51 0.29 2x5 2 Window NE Wall (Back -45) � - - 1 10.0 0.51 0.29 5x4 Window NE Wall (Back J5' -- - 1 20.0 0.51 0.29 8x8 Window SE Wall (Right:!- ,35) 8.0 8.0 0.938 60.0 0.51 0.29 8x4 Window NW Wall (L,N" 315) 8.0 4.0 1 32.0 0.51 0.29 6x8 Window NW WaO(,l?eft-315) 6.0 8.0 1 48.0 0.51 0.29 6x6 Window NW-WaII'(Left-315) -- -- 1 36.0 0.51 1 0.29 DOORS �w 01 02 03 04 Name Side of Building Area (ft2) U -factor solid Door ^s�� SW Wall 20.1 0.50 o®� Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-10-08 14:05:09 _a CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Moore Casita - Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CF*F-01 Page 4 of 8 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09' 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 8x8 6. 0.1 6 6 0 0 0 0 0 0 0 0 0 8x4 6 0.1 6 6 0 0 0 0 0 0 0 0 0 6x8 6 0.1 6 6 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 0405 06 Construction Name Surface Type Construction Type Framing=W Total Cavity R -value Assembly Layers 2x4 Top Cho d of Cavity /Frame: no insul. /2x4 Top Chrd Roof Trusst@ 24 in. Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling OAC'✓ none Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board A► • Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic Ceilings.(below attic) Wood Framed Ceiling 2 T@ 16 in. 0. C. R 38 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board o Cavity/Frame: R-21 /2x6 R-21 Wall (W21.2x6.16) Exterior Walls Wood Framed Wall, 2x6'@ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking _ter SLAB FLOORS 01 02 �� 03 04 05 06 07 Name Zone �� Area (ft2) Perimeter (ft) Edge Insula R -value& Depth Carpeted Fraction Heated Covered Slab Casita v 571 126 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION A. 01 �� 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building EnyelPRe Air Leakage ACH a 50 Pa Not Required i Not Required Not Required -- WATER.HEATING SYSTEMS 01r 02 03 04 Name ., �� Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Pipe Insulation, All Lines 1 0.0% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 14:05:09 CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CFOF-01 Page 5 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING -. HERS VERIFICATION 01 02 .03 04 05 06 07 Name Pipe Insulation Parallel Piping �► Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a&� n/a n/a SplitAirCond - Split Eaf conditioning n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Efficiency Heating System . Cooling System Name System Type EER SEER Zonally Controlled ® HERS Verification Distribution SplitAirCond - Split Eaf conditioning Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC 1 casital Other Heating and Cooling System 60 Heating Com ent 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 571 HVAC - HEATING SYSTEMS 01^ w� 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 �1 03 04. 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split Eaf conditioning 13 1 17 7 No No Cooling Component system .®!_ Registration Number: 0� CA Building Energy Efficiency Standards` - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 14:05:09 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CFOF-01 _ Page 6 of 8 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge . Cooling Component 1 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Required Supply Duct Not Required Not Required Not Required Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located entirely in conditioned space Sealed and tested 8 (y! Conditioned Zone Conditioned Zone None Air.Distribution System 17hers-dist �� W9 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03,&W 04 05 O6 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Required `�6.0 Not Required Not Required Not Required HVAC -FAN SYSTEMS _0 01 4020 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required ..-.A, HVAC FAN SYSTEMS - HERS VERIFICATION �v 01 ( :r 02 03' Name VerifiedFanWatt Draw Required Fan Efficiency (Wafts/CFM) HVAC Fan 1 -hers -fan Required 0.58 =--a IAQ (Indoor Air Quality) FANS �. 01 03 04 05 06 ��U2� IAQ Recovery Name PIAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification SFam IAQVentRpt 09 35.71 0.25 Default 0 Required 1w e®� Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 14:05:09 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 001) Project Name: Moore Casita Calculation. Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis . Input File Name: Moore Casita-Pitchford-14.xml CF1.tF-01 Page 7 of 8 - COOLING VENTILATION 01 02 03 04 05 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans HERS Verification WH Fan 1 61 0.52459 1 Required ®t► V� V® V� Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 14:05:09 CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD Project Name: Moore Casita Ca culation Date/Time: 14:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml CF1*F-01 Page.8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signal Jon d. Scott Jon Scott Company: Signature Date: Scott Design and Title 24, Inc, 10/8/2014 Address: CEA/HERS Certification Identification (If applicable): 77=085 Michigan Drive City/State ip: Palm Desert, CA 92211 Phone: `;�► (7760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT_ I certify the following under penalty of pedury, under the laws of the State of California: oma% 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility forr-to building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Comp it ante are consistent with the i ati vided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency or approval with thi nng p p ca • Responsible Designer Name: espon ' Desi e. 09 Robert A. Pitchford ate Signed: Company: v Robert A. Pitchford Design and Drafting 9 Address: � License: 77-622 Country Club STE O ;e City/State/Zip: Phone: Palm Desert, CA 92211 ,� (760) 346-2856 ni to Registration Number: t@� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 14:05:09 • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Moore Residence Casita Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Add itior/Alteration Date 10/8/2014 Project Address 79-731 Arnold Palmer La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 571 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R38 571 New Wall Wood Framed R 21 2,444 New Door Opaque Door - no insulation 20 New Slab Unheated Slab -on -Grade - no insulation 571 Perim = 126' New Demising Wood Framed R 13 126 New FENESTRATION I Total Area: 216TGlaing Percentage: 37.8%1New/Altered Averace U -Factor: 0.51 Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status Rear (NE) 40.0 0.510 0.29 none none Bug Screen New Right (SE) 60.0 0.510 0.29 6.0 none Bug Screen New Left (NM 80.0 0.510 0.29 6.0 none Bug Screen New Left (NW) 36.0 0.510 0.29 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 17.7 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 casita Ducted Ducted Conditioned 8.0. New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 50 0.66 All Pipes Ins New EnemvPro 6.3 by EnemySoft User Number. 6712 RunCode: 2014-10-08714:05:42 /D: Pae 11 of 18 � � 1 4 4 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1R Project Name Date Moore Residence Casita 1101812014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum compoient performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirerrents of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when s ecmed on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or ou:doors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is greater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building rc'ect. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire open ng of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six sq -pare inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control aevice. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances ars certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3 c'5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 12 of 18 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R Project Name Date Moore Residence Casifa 10/8/2014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, mus- be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requ rements of Standards Table 120.3-A. 150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment mainteiance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other dict -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal o enin s greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back ribber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual swelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the soace where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and A=eptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Bu6ding Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve muirements of 150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c)- §150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an o_it ut frequency - 20 kHz. §150.0(k)1E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 13G0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 13 of 18 r 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 ,of 3 MF -1 R Project Name Date Moore Residence Casita 1101812014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens s'nall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft' or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when al lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact CC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumirmire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with s gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions cf items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, baconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site sha I comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0 130.2, 130.4, 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and epiress. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 14 of 18 k: I 0 • 4 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name oore Residence Casita Date 10/8/2014 System Name HVAC 1 casita Floor Area 571 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,019 Return Vented Lighting Return Air Ducts Return Fan Ventilation 133 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible La-ent CFM Sensible Output perSystem 41,000 15,148 1,121 469 19,937 Total Output Btuh 41,000 0 Output Btuh/s ft 71.8 219 237 Cooling System 01 0 Output perSystem 24,800 5,919 2,374 133 6,483 Total Output Btuh 24,800 0 3,496 0 Total Output Tons 2.1 219 237 Total Output Btuh/s ft 43.4 Total Output s ft/Ton 276.3 21,505 26,894 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24ANB724-58CVX040 18,244 3,446 41,000 Airflow cfm/s ft 1.40 Airflow cfm/Ton 387.1 Outside Air % 16.7% Total Adjusted System Output 18,244 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,446 41,000 Aug13 PM Jan 1 AM Outside Air cfm/s ft 0.23 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 133 cfm 72 OF 64 OF 112 OF 112 OF f n � Heating Coil Supply Fan 112 OF 800 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 133 cfm 70 / 61 OF 4 :0, 77/64°F 56/55°F 56/55°F c O c Cooling Coil Supply Fan 56 / 55 OF 800 cfm 58.5% ROOM 70 / 61 OF a 1 1 1 d I Energ Pro 6.3 by Energ Soft User Number: 6712 Run Code: 201410-08T14:05:42 /D: Page 15 of 18 1� Q 6 • C. • ROOM LOAD SUMMARY Project Name Date Moore Residence Casita 10/8/2014 System Name Floor Area HVAC 1 casita 571 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name =Roonn Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Casita Casita 1 1,019 15,148 1,121 1,019 15,148 1,121 469 19,937 PAGE TOTAL TOTAL` 1,019 15,148 1,121 . 469 19,937 1, 019 15,148 1,121 469 19, 937 Total includes ventilation load for zonal systems. EnergyPro 6.3 by Ene Soft User Number: 6712 RunCode: 2014-10-08714:05:42 /D: Pae 16 of 18 .ry r a It, • ROOM HEATING PEAK LOADS Project Name Moore Residence Casita Date 10/8/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 571.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT of = = = = = = = = = = _ _ - = _ = = - = = _ = = - - _ _ = - = = 46 Btu/hr R-38 Roof Attic. 571.0 0.0260 46 683 R-21 Wall (W.21.2x6.16) 2,443.9 0.0690 46 7,757 Low -E NON METALI.51, .39 . 216.0 0.5100 46 5,067 Wood Door 20.1 0.5000 46 462 Slab -On -Grade perim = 126.0_ 0.7300 46 4,231 Items shown with an asterisk (*).denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 571 X Area another room 14.00 X 0.266 Height ACH Rage Total /60] X AT 18,201 = 1,736 TOTAL HOURLY HEAT LOSS FOR ROOM 19,937 EnergyPro.6.3 by EnergySott User Number: 6712 RunCode: 201410-08714:05:42 ID: Page 17 of 18. 0 E a RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Moore Residence Casita 10/8/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 571.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 0F1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (VIO 571.0 X 0.0260 X 56.0 = 831 R-21 Wall (W.21.2x6.16) (NE) 800.0 X 0.0690 X 29.0 = 1,601 R-21 Wall (W.21.2x6.16) (SE) 440.0 X 0.0690 X 31.0 = 941 R-21 Wall (W.21.2x6.16) (SlM 819.9 X 0.0690 X 31.0 = 1,754 Wood Door (SVV) 20.1 X 0.5000 X 31.0 = 312 R-21 Wall (W.21.2x6.16) (NAA 384.0 X 0.0690 X 30.2 = 801 X X = X X = X X = Page Total 6,240 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 2x5 (NE) 0.0 X 21.0 + 10.0 x 30.3 = 303 2x5 (NE) 0.0 X 21.0 + 10.0 X 30.3 = 303 5x4 (NE) 0.0 X 21.0 + 20.0 }_ 30.3'= 606 8x8 (SE) 60.0 X 21.0 + 0.0 }_ 27.6 = 1,258 8x4 (NVV) 0.0 X 21.0 + 32.0 } 30.3 = 969 6x8 (NVI9 0.0 X 21.0 + 48.0 X 30.3 = 1,454 6x6 (NVtq 0.0 X 21.0 + 36.0 X 30.3 = 1,090 X + _ X + Page Total 5,983 Internal Gain Btu/hr Occupants 1 7 Occupants X 245 Btuh/occ. = 420 Equipment 571 Floor Area X 0.50 w/sgft = 974 Infiltration: 1.064 X 0.94 X 36.64 X 42 = 1,531 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,148 Latent Gain Btu/hr Occupants 1 7 Occupants X 155 Btuh/occ. = 266 Infiltration: 4,771 X 0.94 X 36.64 X 0.00523 = 856 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 266 EnemyPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-10-08714:05:42 /D: Pae 18 of 18