BRES2014-114479731 Arnold Palmer
! IIIIIIIIIIIIIIIIIIIIIIIII 72
4 E - --
78-495 CALLE TAMPICO VOICE(760)777-7125
LA QUINTA,CALIFORNIA 92253 FAX(760)777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS(760)777-7153
BUILDING PERMIT
Date: 2/18/2015
Application Number: BRES2014-1144 Owner:
Property Address: 79731 ARNOLD PALMER RUSS MOORE
APN: 775241037 79731 ARNOLD PALMER
Application Description: 571 SF CASITA ADDITION LA QUINTA,CA 92253
Property Zoning: =—'
Application Valuation: $60,000.00
LCIJ L
C=3 o _a
Applicant: Contractor: N 2 W
ROBERT PITCHFORD D&T REMODELING INC o4' o
77622 COUNTRY CLUB STE.D 44630 FRANKLIN COURT no o"
co o
PALM DESERT,CA 92211 LA QUINTA,CA 92253 d L LJ
LL z
(760)218-6414
Llc.No.:997936
z
-----------------------------------------------'------------=---------------------------------
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under.penalty of perjury one of the following declarations:
9(commencing with Section 7000)of Division 3 of the Business and rofessions Code, I have and will maintain a certificate of consent to self-insure for workers'
and my License is in full force and effect. compensation,as provided for by Section 3700 of the Labor Code,for the performance
License Class: License No.:997936 J
A-\
of t k for which this permit is issued.
I have and will maintain workers'compensation insurance,as required by
Date: Contractor: Section 3700 of the Labor Code,for the performance of the work for which this permit
is issued. My workers'compensation insurance carrier and policy number are:
OWNER-BUILDER DECLARATION Carrier:_ Policy Number:_
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued,I
License Law for the following reason(Sec.7031.5,Business and Professions Code:Any shall not employ any person in any manner so as to become subject to the workers'
city or county that requires a permit to construct,alter,improve,demolish,or repair compensation laws of California,and agree that,if I should become subject to the
any structure,prior to its issuance,also requires,the applicant for the permit to file a workers'compensation provisions of Section 3700 of a Labor Cod ,I shall forthwith
signed statement that he or she is licensed pursuant to the provisions of the comply wit those rovisions.
Contractor's State License Law(Chapter 9(commencing with Section 7000)of Division 3
of the Business and Professions Code)or that he or she is exempt therefrom and the Date: Applicant:
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING:FAILURE TO SECURE WORKERS'COMPEPUTION COVERAGE IS UNLAWFUL,
($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
(_)I,as owner of the property,or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS($100,000). IN ADDITION TO THE COST OF
compensation,will do the work,and the structure is not intended or offered for sale. COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
(Sec.7044,Business and Professions C6dd,>The Contractors'State License Law does not INTEREST,AND ATTORNEY'S FEES.
apply to an owner of propertXwho builds-or improves thereon,and who does.the work
himself or herselfthrough his or her own employees,provide', that the improvements APPLICANT ACKNOWLEDGEMENT
are not intended or offered for sale. If,however,the buildinXi improvement is sold IMPORTANT:Application is hereby made to the Building Official for a permit subject to
within one year of completion,the owner-builder will have the burden of proving that the conditions and restrictions set forth on this application.
he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made,each person at whose
(_)I,as owner of the property,am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit
to construct the project. (Sec.7044,Business and Professions Code:The Contractors' issued as a result of this application,the owner,and the applicant, each agrees to,and
State License Law does not apply to an owner of property who builds or improves shall defend,indemnify and hold harmless the City of La Quinta,its officers,agents,and
thereon,and who contracts for the projects with_a'contractor(s)licensed pursuant to employees for any act or omission related to the work being performed under or
the Contractors'State License Law.). following issuance of this permit.
(_)I am exempt under Sec. .B.&P.C.for this reason 2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit,or cessation of
work for 180 days will subject permit to cancellation.
Date: Owner:
I certify that I have read this application and state that the above information is correct.
CONSTRUCTION LENDING AGENCY I agree to comply with all city and county ordinances and state laws relating to building
I hereby affirm under penalty of perjury that there is a construction lending agency for construction,and hereby authorize representatives of this city to a upon he a ove•
the performance bf the work for which this permit is issued(Sec.3097,Civ.C.). mentioned ope y for inspection purposes.
Lender's Name: Date: Signature(Applicant or Agent):
Lender's Address:
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT , PAID PAID DATE
ADDITION,EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
ADDITION,EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY. AMOUNT PAID PAID DATE
ADDITION,FIRST 100 SF 101-0000-42400 0 $120.83 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
ADDITION,FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00
PAID BY METHOD RECEIPT# CHECK#• CLTD BY
Total Paid forADDITION: $371.73 $0.00
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
HOURLY PLAN CHECK-YES 101-0000-42600 1.5 $105.00 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
Total Paid for BLDG CITY STAFF-PER HOUR: $105.00 $0.00.
DESCRIPTION ACCOUNT QTY1 AMOUNT PAID PAID DATE
BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $3.00 $0.00
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
RESIDENTIAL,FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
RESIDENTIAL,FIRST 1,000SF,PC 101-0000-42600 0 $47.86 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
Total Paid for ELECTRICAL-NEW CONSTRUCTION: $192.89 $0.00
DESCRIPTION ACCOUNT QTY AMOUNT PAID . PAID DATE
CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
FURNACE 101-0000-42402 0 $36.26 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
I
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
FURNACE PC 101-0000-42600 0 $24.17 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
j
' DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
VENT FAN 101-0000-42402 0 $12.09 $0.00
` PAID BY METHOD RECEIPT# CHECK# CLTD BY
I
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
VENT FAN PC 101-0000-42600 0 $4.83 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
I
Total Paid for MECHANICAL: $137.78 $0.00
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
FIXTURE/TRAP 101-0000-42401 . 0 $48.36 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
J FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $0.00
4 PAID BY METHOD RECEIPT# CHECK# CLTD BY
' DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
I GAS SYSTEM,1-4 OUTLETS 101-0000-42401 0 $12.09 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
I DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
i
I GAS SYSTEM,1-4 OUTLETS PC 101-0000-42600 0 $24.17 $0.00
I PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE
ROOF DRAIN 101-0000-42401 0 $12.09 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY I AMOUNT PAID PAID DATE
1 1
ROOF DRAIN PC 101-0000-42600 0 $12.09 $0.00
PAID BY METHOD ` RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE
WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
DESCRIPTION ACCOUNT_ QTY AMOUNT PAID PAID DATE
WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
Total Paid for PLUMBING FEES: $176.50 $0.00
DESCRIPTION ACCOUNT QTY AMOUNTPAID PAID DATE
SMI-RESIDENTIAL 101-0000-20308 0 $7.80 $0.00
PAID BY METHOD RECEIPT# CHECK# CLTD BY
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $7.80 $0.00
TOTALS: $994.70 $0.00
i
r
n
e
w
$rE Permit Details PERMIT NUMBER
ofLa Quinta : d i
i
Description:571 SF CASITA ADDITION
3
Type:BUILDING,RESIDENTIAL Subtype:.ADDITION Status:APPROVED Applied:10/23/2014 KHE
r
Parcel No:775241037 Site Address:79731 ARNOLD PALMER,CA Approved:1/8/2015 AAL 4
Subdivision:TR 21381-1 CM 059/074 SEE ASR MB Block: Lot:3 Issued:
769/41 FOR CM
C
Lot Sq Ft:0 Building Sq Ft:0 Zoning: Finaled: I
Valuation:$60,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings:0 No.Stories:0 No. Unites:0
Details: NEW ATTACHED CASITA(571 SF) ?
Applied to Approved
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
NOTE PHILIP 1UAREZ 1/9/2015 1/9/2015 ROB PITCHFORD CAME AND BROUGHT HOA APPROVAL .
LETTER PUT IN FILE
PLAN CHECK COMMENTS
FROM CONSULTANT KAY HENSEL 11/7/2014 11/7/2014 STRUC RFC 11/6/14
RECEIVED
PLAN CHECK COMMENTS STRUCTURAL CONTENT APPROVED PER YOUNG
FROM CONSULTANT PHILIP JUAREZ 1/6/2015 1/6/2015 ENGINEERING.
RECEIVED
PLAN CHECK PICKED UP MARY FASANO 11/17/2014 11/17/2014
PLAN CHECK SUBMITTAL
RECEIVED KAY HENSEL 10/23/2014 10/23/2014
RESUBMITTAL KAY HENSEL 12/19/2014 12/19/2014
Printed:Wednesday,February 18,2015 11:39:54 AM 1 of 5
• CRJ LJ SYSTEMS .
a ui Q•cy
o¢ �
L
Permit Details PERMIT NUMBER
. i i i
City of La Quinta
SENT TO PLAN CHECK KAY HENSEL 10/23/2014 10/23/2014 STRUC TO YOUNG DUE 11/6
CONSULTANT
SENT TO PLAN CHECK KAY HENSEL 12/19/2014 12/19/2014 STRUC TO YOUNG-DUE 1/5/15
CONSULTANT
TELEPHONE CALL ARMEN ALTOUNIAN 1/8/2015 1/8/2015 LEFT MESSAGE FOR ROB PITCHFORD.PLANS APPROVED AND
READY FOR PICK UP.
TELEPHONE CALL JIM JOHNSON 11/7/2014 11/7/2014 CALLED ROB PITCHFORD @ 346-2856.PLANS READY FOR
CORRECTIONS,GOT MESSAGE MACHINE
CONDITIONS
CONTACTS
NAME TYPE. NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT ROBERT PITCHFORD 77622 COUNTRY CLUB PALM DESERT CA 92211
STE.D
CONTRACTOR D&T REMODELING INC 44630 FRANKLIN LA QUINTA CA 92253
COURT
OWNER RUSS MOORE 79731 ARNOLD LA QUINTA CA 92253
PALMER
FINANCIAL • • •
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT# CHECK# METHOD PAID BY CLTD
BY
ADDITION,EA 101-0000-42400 0 $62.36 $0.00
ADDITIONAL 500 SF
ADDITION,EA 101-0000-42600 0 $17.40 $0.00
ADDITIONAL 500 SF PC
ADDITION,FIRST 100 SF 101-0000-42400 0 $120.83 $0.00
ADDITION,FIRST 100 SF
PC 101-0000-42600 0 $171.14 $0.00
Total Paid forADDITION: $371.73 $0.00
Printed:Wednesday,February 18,2015 11:39:54 AM 2 of 5
• CRSYS7EMS
j"a a q„�yG
a� o
NUMBERPermit Details PERMIT
,+
may ` i I '
City of La Quinta
c e5`
DESCRIPTION y ACCOUNT �'- CITY i AMOUNT PAID PAID DATE RECEIPT# _CHECK# ^METHOD PAID BY CLTD
BY
HOURLY PLAN CHECK- 101-0000-42600 1.5 $105.00 $0.00
YES
Total Paid for BLDG CITY STAFF-PER HOUR: $105.00 $0.00
BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION
$3.00 $0.00
BSA:
RESIDENTIAL,FIRST 101-0000-42403 0 $145.03 $0.00
1,000SF
RESIDENTIAL,FIRST 101-0000-42600 0 $47.86 $0.00
1,OOOSF,PC
Total Paid for ELECTRICAL-NEW CONSTRUCTION: $192.89 $0.00
CONDENSER/COMPRES 101-0000-42402 0 $36.26 $0.00
SOR
CONDENSER/COMPRES 101-0000-42600 0 $24.17 $0.00
SOR PC
FURNACE 101-0000-42402 0 $36.26 $0.00
FURNACE PC 101-0000-42600 0 $24.17 $0.00
VENT FAN 101-0000-42402 0 $12.09 $0.00
VENT FAN PC 101-0000-42600 0 $4.83 $0.00
Total Paid forMECHANICAL: $137.78 $0.00
FIXTURE/TRAP 101-0000-42401 0 $48.36 $0.00
FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $0.00
GAS SYSTEM,1-4 101-0000-42401 0 $12.09 $0.00.
OUTLETS
GAS SYSTEM,1-4 101-0000-42600 0 $24.17 $0.00
OUTLETS PC
ROOF DRAIN 101-0000-42401 0 $12.09 $0.00
Printed:Wednesday, February 18,2015 11:39:54 AM 3 of 5
R?LJ iJ SYSTEMS
DetailsPermit
S
City of La Quinta BRE&I
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT# CHECK# •METHOD PAID BY CLTD
BY
ROOF DRAIN PC 101-0000-42600 0 $12.09 $0.00
WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00
WATER HEATER/VENT 101-0000-42600 0 $7.25 $0.00
PC
Total Paid for PLUMBING FEES: $176.50 $0.00
SMI-RESIDENTIAL 101-0000-20308 1 0 $7.80 $0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $7.80 $0.00
TOTALS: • $0.00
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES
DATE DATE
FINAL"
PARENT PROJECTS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
NON-STRUCTURAL ARMEN 10/23/2014 11/6/2014 10/27/2014 REVISIONS REQUIRED CORRECTIONS RFC
ALTOUNIAN REQUIRED
STRUCTURAL JIM JOHNSON 10/23/2014 11/6/2014 11/7/2014 REVISIONS REQUIRED CORRECTIONS 1ST.STRUC PLAN CHECK CORRECTION REQUIRED
NON-STRUCTURAL ARMEN 12/19/2014 1/5/2015 12/22/2014 APPROVED 2ND PLAN CHECK APPROVED
ALTOUNIAN
STRUCTURAL JOHN 12/19/2014 1/5/2015 12/19/2014 APPROVED 2ND PLAN CHECK STRUC DUE BACK 1/5/15
THOMPSON APPROVED
BOND INFORMATION
Printed:Wednesday,February 18,2015 11:39:54 AM 4 of 5 ?`? V
SYSTEMS
7 •
_.
a. s w
NY
4 w r w« x ii L fu4
._ t � x# w
'3.r`i' se' f _
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR, ETRAKIT ENABLED
DOC 10/27/2014 ARMEN ALTOUNIAN N/S 1ST REVIEW 79-731 ARNOLD 0
COMMENTS.docx PALMER.docx
DOC 2/18/2015 STEPHANIE KHATAMI SCHOOL FEE RECEIPT SCHOOL FEE LETTER- 0
BRES2014-1144 BRES2014-1144.pdf
Printed:Wednesday,February 18,2015 11:39:54 AM 5 of 5
(r ii IJV SYSTEMS
IIIIIIIIIIIIIIIIIIIIIIIII 73 44
0
IE
- P.O. BOX 1504 No. 002875
Building 79-731 Avmld LA QUINTA,CALIFORNIA 92253
Address
Owner
BUILDING: TYPE CONST.
Mailing OCC:GRP,
Address 7v M.? A.P. Number
CityJZip Tel.
.. ,fly, _ 92260 .560 Legal Description
Contractor G.H. P0101r3 Project Description
.
Address.
P.O. alm 399
City Zip Tel: -
rat city
State Lic. City
&Classif. 275796 Lic.# Sq. Ft. No. No. Dw.
' Arch., Engr.,
Size Stories - Units
Designer New ❑ Add ❑ Alter❑ Repair ❑ Demolition ❑
Address Tel.
City Zip State T—bol Wild Sim
- Lic.#
LICENSED CONTRACTOR'S DECLARATION,
I hereby affirmlthat I am licensed under provisions of:Chapter 9(commencing with Section
7000)of Divisioon 3 of the-Business and Professions,Code,.and my license is in full force and
effect.. Il .+` f ✓ ter '= `3 "
SIGNATURE DATE
' OWNER-BUILDER DECLARATION Estimated ValUatiOn / y / r
I hereby affirm that I am exempt from the Contractor's License Law for the following '20;*.00.06
reason: (Sec. 7031.5,Business and Professions Code: Any city or county.which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to PERMIT - AMOUNT
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section.7000) of
'Division 3 of the Business and Professions Code, or thathe is exempt therefrom, and the basis - Plan Chk. De
for the alleged exemption. Any violation of Section 7031.5 by'any applicant for a permit Dep..
• subjects the applicant to a civil penalty of not more than five hundred dollars(8500). ' '
❑I,as owner of the property,or my employees with wages as their sole compensation,will Plan Chk. Bal. 95-22
do the work,and the structure is not intended or offered for sale.(Sec. 7044,Buisness and Const. 146.54Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon-and who does such work himself or through his own employees, Mech.
provided that such improvements are not Intended or.offered for sale. If, however, the building ,
or improvement is sold within one year of completion, the owner-builder will have the burden Electrical proving that he did not build or improve for the purpose of sale.) ..
❑ I,as owner of the property,am exclusively contracting with licensed contractors to con- Plumbing
14.00
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. 1.44
such projects with a contractor(s)licensed pursuant to the Contractor's License Law.)
Grading
O 1 am exempt under Sec. . B.&P.C.for this reason
Driveway Enc.
Date owner Infrastructure
WORKERS'COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self-insure, or a certificate of
Worker's Compensation Insurance,or a certified copy thereof.(Sec.3800,Labor Code.) _
Policy No. . .Company -+)
❑Copy is filed with the city. ❑Certified copy is hereby furnished.
_ TOTAL ! 2%.16
CERTIFICATE OF EXEMPTION FROM REMARKS
WORKERS'.COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (8700) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued,I shall not
employ any person in any manner so as to become subject to the Workers'Compensation
Laws of California.
Date Owner-
NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become ZONE: BY:
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith Minimum Setback Distances: '
comply with such provisions or this permit shall be deemed revoked.
Front Setback from Center Line
Rear Setback from Rear Prop. Line
CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued.(Sec.3097,Civil code.) Side Setback from Property Line
Lender's Name
Lender's Address FINAL DATE INSPECTOR
This is a building permit when properly filled out,signed and validated,and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is-correct. Issued by: Date 2-29—S7
Permit
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of-this city to enter the above-
mentioned property for inspection:purposeS-11 -- Validated by:
Signature of applicant r r ``` ~ .!' Date e j', 'j
Mailing Address Validation:
City, State, Zip
Ai231 2 3 16 Ck
HARD COPY
CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES
1ST FL. SO.FT.® $ UNITS
2ND FL. SQ.FT.
YARD SPKLR SYSTEM
POR. SO.FT.® MOBILEHOME SVC. BAR SINK
GAR. SQ.FT.® POWER OUTLET ROOF DRAINS
CAR P. SQ.FT.
DRAINAGE PIPING
WALL SO.FT.® DRINKING FOUNTAIN
SQ FT ® URINAL
ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING
NOTE:Not to be used as property tax valuation FLOOR DRAIN
MECHANICAL FEES WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH)
APPLIANCE DRYER GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY
AIR HANDLING UNIT CFM KITCHEN SINK
ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET'
COMPRESSOR HP POLE,TEM/PERM LAVATORY
HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER
BOILER B.T.U. SO.FT.®c BATH TUB
SQ.FT.®c WATER HEATER
MAX.HEATER OUTPUT,B.T.U. SQ.FT.RESID®11/4 c SEWAGE DISPOSAL
SQ.FT.GAR®3/ac HOUSE SEWER
GAS PIPING
PERMIT FEE PERMIT FEE PERMIT FEE
DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST.FEE ELECT.FEE SMI FEE PLUMB.FEE
STRUCTURE PLUMBING ELECTRICAL HEATING&AIR COND. SOLAR
SETBACK GROUND PLUMBING UNDERGROUND A.C.UNIT COLL.AREA
SLAB GRADE ROUGH PLUMB. BONDING HEATING(ROUGH) STORAGE TANK
FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE
FOUND.REINF. GAS(ROUGH) METER LOOP HEATING(FINAL) OTHER APPJEOUIP.
REINF.STEEL GAS(FINAL) TEMP.POLE
GROUT WATER HEATER SERVICE FINAL INSP.
BOND BEAM WATER SYSTEM
GRADING
LUMBER GR. FINAL INSP. cu.yd.
FRAMING FINAL INSP. $ plus x$ =$
ROOFING REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS.
GARDEN WALL FINAL
1111 IIIIIIIII1111IIII 74 I
IE 44
P.O. BOX 1504 No. 002565
Building Address ? •- LA QUINTA,CALIFORNIA 92253
` . 1 'xf[? i t 't y • . _ ,
Owner
BUILDING: TYPE CONST. OCC:GRP.
Mailing
Address75
' C.tbtWiVe, A.P. Number
City Zip Tel.
92960 Legal Description
Contractor Project Description PM VEW PhaiM 3 C
lmtl. H=t. and Lal-A -
Address P1= 3010 m
Sam
City Zip Tel.
Sam
State Lic. City M= 3971
&Classif. 288130 Lic.# 328 Sq. Ft. b57 No. No. Dw.
Arch., Engr.,
Size *Stories - Units
Designer New Add ❑ Alter ❑ Repair ❑ Demolition ❑
Address Tel.
City Zip State
. . - - Lic.# -
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9(commencing with Section
7000)of ivision 3 of the Business and Professions Code,and my licenseIis in full force and
effect. .. - \ ;, . A r;
SIGNATURE - `4 - DATE
OWNER-BUILDER DECLARATION Estimated Valuation
I hereby affirm that I am exempt from the Contractor's License Law for the following tn
reason: (Sec... f
7031.5,Business and Professions Code: Any city or county which requires a .G- V.84•
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file,a signed statement that he is licensed pursuant to PERMIT ' AMOUNT
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that:he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permitPlan Chk. Dep.
subjects the applicant-to a civil penalty of not more than rive hundred.dollars($500).
O I,as owner of the property,or my employees with wages as their sole compensation,will Plan Clik. Bal. ' ,
do the work,and the structure is not intended or offered for sale.(Sec. 7044,Buisness and Const. $ Q
Professions Code: The Contractor's License Law does not apply.to an owner of property who •
builds or improves thereon and who does such work himself or through his own employees, Mech.
provided that such improvements are not intended or offered for sale. If,.however, the building
or improvement is sold within one year of completion, the owner-builder will have the burden Electrical 3+
of proving that he did not build or improve for the purpose of sale.)
O I,as owner of the property,am exclusively contracting with licensed contractors to con- Plumbing 148+50
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. 17.54
such-projects with a contractor(s)licensed pursuant to the Contractor's License Law.)
Grading
O lam exempt under.Sec. B.&P.C.for this reason
Driveway Enc.
Date Owner Infrastructure 2,000.00
WORKERS'COMPENSATION DECLARATION
I hereby affirm that I"have a certificate of consent to self-insure, or a certificate of
Worker's Compensation Insurance,or a certified copy thereof.(Sec.3800,Labor Code.)
Policy No. Company
❑Copy is filed with.the city. ❑Certified copy is hereby furnished.
_ TOTAL
CERTIFICATE OF EXEMPTION FROM REMARKS
WORKERS'COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.) -
I certify that in the performance of the work for which this permit is issued,I shall not
employ any person in any manner so as to become subject*to the Workers'Compensation
Laws of California.
Date • Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY:
subject to the Workers' Compensation provisions of the'Labor Code, you must forthwith Minimum Setback Distances:
comply with such provisions or this permit shall be deemed revoked.-
Front Setback from Center Line
Rear Setback from Rear Prop. Line
CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line
I hereby affirm that there is a construction lending agency for the performance of the '
work for which this permit is issued.(Sec.3097,Civil Code.) Side Setback from Property Line
Lender's Name
Lender's Address
This is a building permit when properly filled out,signed and validated,and is.subject to FINAL DATE INSPECTOR
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and stale that the above information is correct. Issued by: Date Permit
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-
mentioned property for inspection purposes. Validated by:
Signature of applicant t- Date -r','
Mailing Address Validation:
City, State, Zip
A 6 3 1 0 .9 10 385548 ft
HARD COPY
CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES
1ST FL. SQ.FT.® $ UNITS
2ND FL. SQ.FT.p
YARD SPKLR SYSTEM
POR. SO.FT.® MOBILEHOME SVC. BAR SINK
GAR. SO.FT.®_ POWER OUTLET ROOF DRAINS
CAR P. SQ.FT.
DRAINAGE PIPING
WALL SQ.FT.
DRINKING FOUNTAIN
SQ.FT.® URINAL
ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING
NOTE:Not to be used as property tax valuation FLOOR DRAIN
MECHANICAL FEES WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH)
APPLIANCE DRYER GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY
AIR HANDLING UNIT CFM KITCHEN SINK
ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET
COMPRESSOR HP POLE,TEMIPERM LAVATORY
HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER
BOILER B.T.U. SQ.FT.®c BATH TUB
SQ.FT.®c WATER HEATER
MAX.HEATER OUTPUT,B.T.U. SO.FT.RESID®11/4 c SEWAGE DISPOSAL
SQ.FT.GAR®3/a,- HOUSE SEWER
GAS PIPING
PERMIT FEE PERMIT FEE PERMIT FEE
DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST.FEE ELECT.FEE SMI FEE PLUMB.FEE
t
STRUCTURE PLUMBING ELECTRICAL HEATING&AIR COND. SOLAR
SETBACK GROUND PLUMBING UNDERGROUND A.C.UNIT COLL.AREA
SLAB GRADE ROUGH PLUMB. BONDING HEATING(ROUGH) STORAGE TANK
FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE
FOUND.REINF. GAS(ROUGH) METER LOOP HEATING(FINAL) OTHER APP./EQUIP.
REINF.STEEL GAS(FINAL) TEMP.POLE
GROUT WATER HEATER SERVICE FINAL INSP.
BOND BEAM WATER SYSTEM
GRADING
LUMBER GR. FINAL INSP.
cu.yd.
FRAMING FINAL INSP. $ plus x$ _$
ROOFING REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
I N SU LATIONISOUN D
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS.
GARDEN WALL FINAL
Bin #
3oACity
h11
of La Quinta
Building et Safety Division
Permit # 14,P.O.
Box 1504, 78-495 Calle Tampico
La Quinw, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Address: -79 — -7?,,/
: Q (" 'e
A P. Number: -*77!57 '24 I % 7 rJ
EAdd
Legal Description: O -j 9 '�. 21 t't_9(ArContraaor:
"�'(j`�
Address:
Project Description:
City, ST, Zip:
r � )r-17�
Telephone:
State Lic. # :
City Lic. #:
., Designer:]
Address: %'7 6 ZZ�
City, ST, Zip:
Telephone: 60
Construction Type: Occupancy:
State Lic. #:
Pro'J ea hype (circle one): New Add'n Altcr Repair Demo
Name of Contact Person:
FtT•C#4�—ep'
`5
Sq. Ft.: Scotties: # Units:
Telephone # of Contact Person: %60 67
0
Estimated Value of Project: 60, coo 9
APPLICANT: DO NOT WRITE BELOW THIS UNE
N Submittal
Req'd Rec'd TRACKING
Plan Sets
PERMlT FEES
a? Plan Check submitted
Structural Coles
Item Amount
a Reviewed, ready for corrections i I Plan
Cbeck Deposit
Truss Caics.
Called Contact Person i Plan Check Balance
Energy Coles,
a Plans picked up i n
Construction
Flood plain plan
Plans resubmitted %Z
1`j Mechanical
Grading plan
2" Review, ready for correctionsrmus Eteelrieal
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
ILO.A. Approval
SALT.
Pians resubmitted
Grading
W HOUSE: -
Review, ready for Developercorrections/issue Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
.LP.P.
Date of permit issue A
School Fees
1D/a3 -91
=-:; ��
2,122 -
NIS 1A1'�'R
b
Total Permit Faes
--.
I
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road Q BERMUDA DUNES 0
V) RANCHO MIRAGE tZ�
Date 2/18/15 La Quinta, CA 92253 INDIAN WELLS ti
No. 31715 ��
PALM QUINTA
(760) 771-8515 �1PINDIO
Owner Moore
APN # 775-241-037
Address 79731 Arnold Palmer
Jurisdiction La Qu:nta
City La Quinta Zip
Permit #
Tract #
No. of Units 1
Type Residential Addition
Lot # No. Street
S.F.
Lot # No. Street S.F.
Unit 1 79731 Arnold Palmer
571 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments Detached Casita
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the fol owing reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.36 X 571 S.F. or $1,918.56 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Chase Bank - Tracy Norblom Check No. 103892953
Bank Name/Recipient of Certificate Telephone
Funding Residential
BY Dr. Gary Rutherford
Superintendent
Fee collected /exemp by S n it rey Payment Recd 'J$0.00
0
$1918.56 'bver:Unde�. r
Signature '
a
NOTICE: Pursuant to Government Code Section 66020(d)(1), this ill erve to notify you that the 90 -day approval period inwhich•you may protest the fees
or other payment identified above will begin to run from the date on ich the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
PGA WEST -
RESIDENTIAL ASSOCIATION, INC.
October 28, 2014
N
JP ` �o �Q MENS
Mr. Russell Moore, Jr. Gam` bel
160 Encinal Avenue Mv�1
Atherton, CA 94027 God
RE: 79-731 Arnold Palmer - Architectural Variance- Casita
Page 1 of 2
Dear Mr. Moore,
The Architectural Committee has reviewed your Architectural Variance submittal of preliminary
plans for a casita addition. The following proposed casita drawings: Sheets L 2, 3 and 4 dated
August 26, 2014, prepared by Robert A. Pitchford, were provided. The proposed casita addition
is acceptable conceptually, but, prior to starting` production drawings . we need a written
confirmation that you are aware there are numerous known and unknown service and utiltty fines
routed through this area of the propgty. The homeowner is responsible to locate and have re-
routed any service lines and maintain the area serviced in operation. - Tae protect .is not
acceptable to proceed until this matter is finalized The property drame including roof drainage
will have to also be addressed to assure proper flow and travel to the street from both the rear
yard and sided_.
The following conditions and/or requirements are pertinent subject to finalizing the utility and
drainage issues.
1.
2.
3.
4.
5.
Final Dlans must be submitted for review.
Submit a copy of the City of La Quinta building department permit and the city stamped
plans prior to starting any work.-
The
ork:The homeowner and contractor are to meet with the Landscape/Irrigation Manager, Bill
Bobbitt, and the Maintenance/Lighting Manager, William Aceves, prior to the start of
any work. It is the responsibility of the homeowner to locate and mair_tain the operation
of the existing irrigation and lighting systems.
The HOA is not responsible for verifying property lines, easements and existing utility
services.
The relocation and/or modification of the existing utilities, electrical, irrigation and
drainage :is to be the responsibility of the. homeowner and done to the building industry
standards based. on this site and the building codes. ..
6. The owner's contractor to remove any -trees. and: shrubbery while preventing ariy damage
to adjacent property:.
The owner is 16'replace. the removed landscaping with a design that provides comparable
landscape privacy for the neighbor. Please submit a revised landscape plan for review by
Bill Bobbitt, Landscape/Irrigation Manager. -
7.
54-320 Southern Hills, La Quinta, California 92253-5665, Telephone 760-771-1234 FAX 760-771-5125
Page 2 of 2
8. The contractor to repair and/or replace any damaged irrigation, landscape, hardscape,
lights or street surface to the satisfaction of the HOA.
9. Contractor to observe. allAssociation rules and regulations. All contractor vehicles to
park on one side of the street only.
10. The contractor may not stockpile any material, equipment or construction debris in the
street. All debris must be cleaned up daily.
11. The street gutters cannot be used for concrete wash out and the contractor is responsible
for keeping the gutter clear and free of debris.
12. All site drainage is to be properly engineered and installed to prevent any flooding.
13. The roof tile color and style is to match the existing.. All stucco, trim and finish details to
. match existing.
14. The homeowner and the contractor . to .. schedule a meeting with. the. landscape and.
irrigation manager and the maintenance manager prior to submitfing a Notice of
Completion.
15. Upon completion of the project, the homeowner is required to provide a signed copy of
the city inspection card and the Contractor Certification letter (enclosedi.
16. A Maintenance and IndemniU AgLeement shall be signed prior to the -tart of work and
reviewed at the completion of the project. Same shall delineate all applicable work,
which current and future owners shall be compelled to solely maintain .and/or replace as
needed and the document shall be recorded with the County of Riverside and runs with
the land.
We reserve the right to make a final inspection of this change to make sure that it matches the
original request. An approval is based only on the aesthetics of your proposed plan and should
not be taken as any certification as to the construction worthiness or structural integrity.of the
proposed change.
We appreciate your cooperation in submitting this request for approval. If I may be of further
assistance, please contact me at the HOA office, (760) 771-1234, Extension 15.
Cordially,
C
Key cGalliard
Operations Manager
For the Architectural Committee
KM/bvf
Enc. 1
cc: Architectural Committee
YOUNG G.
ENGINEERING
S e is : v . c e S
-?�(�f�l�/ZrU�> f sitC�tj7�b�UJi
Letter of Transmittal
To: City of La Quinta Today's Date: 1-6-15
78-495 Calle Tampico City Due Date: 1-5-15
La Quinta, CA 92253 Project Address: . 79-731 Arnold Palmer
Attn: Kay Plan Check #: BRES 2014-1144
❑ Your Pickup
Descriptions:
Revised Structural Plans
Revised Struct. Calcs
Revised Truss
Revised Soils Report
Approved Structural Plans
Approved Structural Calcs
Approved Truss Calcs
Approved Soils Report
Other: _
onj;
If you have any questions, please call.
R ,i ITNTA
Time =.75 HR r,aiF1 nPMENT
This Material Sent f.or:
❑ Your Files ® Per Your Request
❑ Your Review ❑ Approval
❑ Checking ❑ At the request of:
Other:.❑
By: Kathryn Samuels
Palm Desert Office': ® (760) 772-5107
Other: ❑ r
Submittal: ®
1St
❑
4th
' ❑
2nd
❑
5th
❑
3rd
❑
Other:
We are forwarding:
® By Messenger
❑
By Mail (Fed Ex or UPS)
Includes:
# Of
Descriptions:
Includes:
# Of
Copies:
. '
Copies:
❑
Structural Plans
®
1
®
1
Structural Calculations
❑
❑
Truss Calculations Floor
❑
and Roof
❑
Soils Report
❑
®
2
Structural Comment List/
❑
Responses
®
1
- Redlined Structural Plans
❑
❑
Redlined'Structural Calcs
❑
❑
Redlined Truss Calcs
❑
❑
Redlined Soils Reports
❑
Comments:
Structural content is aoorovable.
❑ Your Pickup
Descriptions:
Revised Structural Plans
Revised Struct. Calcs
Revised Truss
Revised Soils Report
Approved Structural Plans
Approved Structural Calcs
Approved Truss Calcs
Approved Soils Report
Other: _
onj;
If you have any questions, please call.
R ,i ITNTA
Time =.75 HR r,aiF1 nPMENT
This Material Sent f.or:
❑ Your Files ® Per Your Request
❑ Your Review ❑ Approval
❑ Checking ❑ At the request of:
Other:.❑
By: Kathryn Samuels
Palm Desert Office': ® (760) 772-5107
Other: ❑ r
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
CF1 R -PRF -01
Pagel of 8
GENERAL INFORMATION
01 Building Complieswith Computer. Performance` / %'"-
02 This building incorporates features that require field testing and/or verificatior"by a certified HERS rater under: -the supervision of a CEC-approved HERS provider.
01
Project Name Moore Casita
04 05
1 06 07
02
Calculation Description Title 24 Analysis
Proposed Compliance
Design Margin
Percent
Improvement
03
Project Location 79-731 Arnold Palmer
-52.9%
Space Cooling 233.43
04
A City La Quinta
05
Standards Version Compliance 2015
06
Zip code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3 (650)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 225
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 571
15
Number of Zones 1
16
Slab Area (FT2) 571
17
Number of Stories 1
18
Addition Cond. Floor Area NA
19
Natural Gas Available Yes
20
. Addition Slab Area (FT2) NA
21
Glazing Percentage (%) 37.8%
COMPLIANCE RESULTS."^`'
01 Building Complieswith Computer. Performance` / %'"-
02 This building incorporates features that require field testing and/or verificatior"by a certified HERS rater under: -the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Feat6res shown below
ENERGY USE SUMMARY
04 05
1 06 07
08
Energy Use Standard
(kTDV/ft) Design
Proposed Compliance
Design Margin
Percent
Improvement
Space Heating 8.37
12.80 -4.43
-52.9%
Space Cooling 233.43
230.43 3.00
1.3%
IAQ Ventilation 2.79
2.79 0.00
0.0%
Water Heating 31.22
26.41 4.81
15.4%
Photovoltaic Offset ----
0.00 0.00
--
Compliance E-4-
r n 0 w ��2�7.5��81
272.43 3.38
1.2%
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE) &I bCBY4A;k%
Registration Number: 214-N0
CA Building Energy Efficiency Standards - 2013 Residential Compliance
REQ®
3
O OCT 2 3 (2014
Registration Date/Time: 2014-10-0801-PY41C)?, i • vPriv Ia HERS Provider: CaiCERTs inc.
Report Version - CF1R-09042014-650 COMMUNI T YG �Je:i )RP-v.'I,Report Generated at: 2014-10-08 14:05:15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
' Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Window overhangs and/or fins
CF1 R -PRF -01
Page 2 of 8
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below, reclure field verification by a certified HERS Rater.
• IAQ mechanical ventilation
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV, energy offset by an
on-site renewable energy system. t
Reference Energy Use Energy Design Rating MarginPercent Improvement
Total Energy (kTDV/f2)*' i' 369.21. 365.83 3.38 0.9%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU) r,'ipgl .E' V • a
BUILDING - FEATURES INFORMATIONk� ';1... ,'
01
. ^ 02= `' ' ` -i `
z .: 03 �. " _ -
„• ,.04 fr
05-
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Moore Casita
571 it
1
3
1
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
- HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Casita
Conditioned
HVAC 1 casital
571
14
DHW Sys 1
Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 14:05:15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xmi
CF1 R -PRF -01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window Area (ft)
Tilt(deg)
NE Wall
Casita
R-21 Wall (W.21:2x6.16)
45
Back
840
40
90
SE Wall
Casita
R-21 Wall (W.21.2x6.16)
135
Right
500
60.032
90
SW Wall
Casita
R-21 Wall (W.21.2x6.16)
225
Front
840
0
90
NW Wall
Casita'
R-21 Wall (W.21.2x6.16)
315
Left
500
116
90
Roof
Casita
R-38 Roof Attic
SE Wall (Right -135)
571
8.0
0.938
ATTIC
01 02 03 04 05 06 07
Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Attic Roof Cons ; 3 0.1 0.85 No No
WINDOWS
Ol
02
4
i� i x f 03 Y - V `
7..:. 1.
`' o-' 04'
1 -) r
65 >� -
06
07
08
09 10
Name
Type
y _�
ys� ►•c # � Y.. k Width(ft rHeight.
w,!Surface (Orientation`Azimuth), ' �.L" - �,),. f (ft):'•
, .-^ -MArea
Multip ier
(ft2)
U -factor
SHGC Exterior Shading
2x5
Window
"' ' "- IiNE Wall (Back -45)
" - -
- -
1
10.0
0.51
0.29
2x5 2
Window
r "' NE Wall (Back -45)
-
-
1
10.0
0.51
0.29
5x4
Window
!NE Wall (Back -45)
--
--
1
20.0
0.51
0.29
8x8
Window
SE Wall (Right -135)
8.0
8.0
0.938
60.0
0.51
0.29
8x4
Window
NW Wall (Left -315)
8.0
4.0
1
32.0
0.51
0.29
6x8
Window
NW Wall (Left -315)
1 6.0
8.0
1
48.0
0.51
0.29
6x6
Window
NW Wall (Left -315)
- -
-
1
36.0
0.51
0.29
DOORS
01 02 03 04
Name Side of Building Area (ft) U -factor
solid Door SW Wall 20.1 0.50
Registration Number: 214-N0113564A-000000000-0000 Registration Date/Time: 2014-10-0814:17:41
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650
HERS Provider: r CaICERTS inc.
Report Generated at: 2014-10-08 14:05:15
PI
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title.24 Analysis Input File, Name: Moore Casita-Pitchford-14.xml
CFI R -PRF -01
Page 4 of 8
OVERHANGS AND FINS
01
02 03 04 05' 06
07 08 09 10 .
11 12 13 14
05
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth Top Up
Dist R
Bot Up
fixR
fi
01
6
6
n
n
n
n
0
0 0
0
n
8x4
6
0.1
6
6
0
0
0
0
0
0 0
0
0
6x8
6
0.1
6
6
0
0
0
0
0
0 1 0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name.
Surface Type
Construction Type
Framing
Total Cavity R -value
Assembly Layers
2x4 Top Chord of
Cavity/ Frame: no insul. /2x4 Top Chrd
.`
Roof Truss @ 24 in..
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Coris
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
,!
�.
&-i16-g.
,x
Cavity / Frame: R-9.1 / 2x4
R-38 Roof Attic
Ceilings (below attic) ry
f
It
Wood Framed Ceiling
2x4 @ 16 m iO.C:
„� R 38
Over Floor Joists: R-28.9 insul.
i
d�;' i f' } ;: �!
f • _ �,,
` t• •+.
glnside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
.
R-21 Wall (W.21.2x6.16)
Exterior Walls *•'
`N:l Wood Framed Wall
2x6 @ 16 in: O'. C.
•' R'21
Exterior Finish: Wood Siding/sheathing/decking
r
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated
Covered Slab Casita 571 126 None 0.8 No
BUILDING ENVELOPE HERS VERIFICATION
01. 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
'Not Required Not Required Not Required --
WATER HEATING SYSTEMS ,
01 02 03 04
Name Distribution Type Number of Heaters Solar Fraction (%)
DHW Sys 1 Pipe Insulation, All Lines 1 0.0%
Registration Number: 214-N0113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -09042014-650
HERS Provider: CaICERTS inc.
Report Generated at: 2014-10-08 14:05:15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis
Input File Name: Moore Casita-Pitchford-14.xml
CF1 R -PRF -01
Page 5 of 8
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
n/a
n/a
n/a
SplitAirCond -Split air conditioning
n/a
HVAC SYSTEMS
01
02
03
04
05
06
07
`
—Heating System / -
' f.-`CCooling System
Name
System Type
EER SEER
�,,�
! A / % f
HERS Verification
Distribution
SplitAirCond -Split air conditioning
Floor Area
Name
System%Type
Name Ducted
R
�, NameDucted
System
Fan System
Served
1 -hers -cool
Cooling j '
Air Distribution
HVAC 1 casital
Other Heating and Cooling System~
Heating Component 1
Yes'Component
1
Yes
System 1
HVAC Fan 1
571
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06.
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond -Split air conditioning
13.1
17.7
No
No
Cooling Component
system
1 -hers -cool
Registration Number: 214-N0113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 14:05:15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xmi
CFI R -PRF -01
Page 6 of 8
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
IAQ Watts/CFM
Verified Duct Design
Name
Duct Leakage Verification
Supply Duct
Verified Duct Location
Return Supply
Air Distribution System 1 -hers -dist
Name
Type
Duct Leakage
Insulation R -value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located entirely in
Sealed and tested
8
Conditioned Zone
Conditioned Zone
None
Air Distribution
conditioned space
System 1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
06
Name
IAQ CFM
IAQ Watts/CFM
Verified Duct Design
Name
Duct Leakage Verification
I Duct Leakage_Target (%) 1 i
Verified Duct Location
Return Supply
Air Distribution System 1 -hers -dist
Required .. 1p,
6A f /
�.^ Not Required
Not Required Not Required
, +moi I }_a! s_ '_ 't. ' (L '^
HVAC -FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required 0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
35.71
0.25
Default
0
Required
Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 14:05:15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Moore Casita Calculation. Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
CFI R -PRF -01
Page 7 of 8
COOLING VENTILATION
01 02 03 04 05
Name Cooling Vent. CFM Cooling Vent Watts/CFM Number of Fans HERS Verification
WH Fan 1 61 0.52459 1 Required
leo
Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 14:05:15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014 'Page 8 of 8
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xmi
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2014-10-08 14:10:56
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business,and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance..
2. - I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. 1
3. The building design features or system design features identifiedon.-this-Certificate of Compliance are -consistent -with the information provided on other applicable compliance documents,
worksheets, calculations, plans and p cificafions submitted•to the enforcement agency for appFoval with this building permit application.
Responsible Designer Name:
.j � fir• `` ;? J�t?
Responsible Designer Signature:
Pitchford_�`if=�
Robert
Company: T- 'Date
Signed:"
Robert A. Pitchford Design & Drafting
2014-10-08 14:17:41
Address: t
License:
77-622 Country Club Drive, Suite O
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 346-2856 ,
I
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document,.and in noway implies Registration Provider responsibility for the accuracy of the
'information. .
Registration Number: 214-No113564A-000000000-0000 Registration Date/Time: 2014-10-08 14:17:41 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014=650 Report Generated at: 2014-10-08 14:05:15
i
COPY
BUILDING ENERGY ANALYSIS REPORT
PROJECT:*
Moore Residence Casita
79-731 Arnold Palmer
La Quinta, CA 92253
Project Designer:
Robert A. Pitchford Design and Drafting
77-622 Country Club STE 0
Palm Desert, CA 92211
.(760) 346-2856
Report Prepared by:,
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Pa[PQ,D-e K
OCT 23 2014
CI 1-1 . OF LA QUIN-r,'A
CITY OF LA QUINTA
COMMUNITY. DEVELOPNEN I- BUILDING &SAFETY DEPT.
APPROVED
Job Number: FOR CONSTRUCTION
DATE_L/_J5ZKBy
Date:
10/8/201.4
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I EnergyPro 6.3 by EnergySo ft User Number.- 6712 ID: I
I
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis
Input File Name: Moore Casita-Pitchford-14.xml
CFOF-01
Pagel of 8
GENERAL INFORMATION
01 Building Complies with Computer Performance'
02 This building incorporates features that require field testing and/oar verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
01
Project Name Moore Casita
04
05
02
Calculation Description Title 24 Analysis
Energy Use
(kTDV/ft)
Standards
Design
03
Project Location 79-731 Arnold Palmer
Space Heating8
37
04
A City La Quinta
05
Standards Version Compliance 2015
06
Zip code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3 (650)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 225
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FTZ) 571
15 ��
Number of Zones 1
16
Slab Area (FTZ) 571
17(
Number of Stories 1
18
Addition Cond. Floor Area NA
Natural Natural Gas Available Yes
20
Addition Slab Area (FTZ) NA
JAV1
Glazing Percentage (%) 37.8%
A`W
COMPLIANCE RESULTS t6 v
01 Building Complies with Computer Performance'
02 This building incorporates features that require field testing and/oar verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown tielow
�WNERGY USE SUMMARY
04
05
06 07
08
Energy Use
(kTDV/ft)
Standards
Design
Proposed Compliance
Design Margin
Percent
Improvement
Space Heating8
37
12.80 4.43
-52.9%
Space Cooling
a2,33.43
230.43 3.00
1.3%
IAQ Ventilation
2.79
2.79 0.00
0.0%
Water Heating
31.22
26.41 4.81
15.4%
Photovoltaic Offset
Compliance Energy Total's
nn ` --
0.00 0.00
—
275.81
272.43 3.38
1.2%
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
Registration Date/Tis eDATE BY
Report Version - CF
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
CERTIF OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Window overhangs and/or fins
PROJECT HERS FEATURES
CFOF-01
. Page 2 of 8
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below, require field verification by a certified HERS Rater.
• IAQ mechanical ventilation
ENERGY DESIGN RATING �W
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic a_"Ppliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy'Design Rating Margin Percent Improvement
Total Energy (kTDV/f2)' 369.21 365.83 3.38 0.9% 71
includes calculated Appliances and Miscellaneous Energy Use (AMEU) �®
BUILDING - FEATURES INFORMATION v
01
02
03 1•1
AM
04
05
06
07
Zone Name
Zone Type
Number of Dwelling
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (sft)
Units *6111,
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Moore Casita
571
vA
3
1
1
1 .
►7%
ZONE INFORMATION �X
01
02
��v 03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Casita
Conditioned
HVAC 1 casital
571
14
DHW Sys 1
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
144
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE &*OD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis
Input File Name: Moore Casita-Pitchford-14.xml
CFIOF-01 _
Page 3 of 8
OPAQUE SURFACES
01 02 03
.
M
Name Side of Building Area (ft2)
U -factor
solid Door ^s�� SW Wall 20.1
0.50
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window Area (ft2)
Tilt(deg)
NE Wall
Casita
R-21 Wall (W.21.2x6.16)
45
Back
840
40
90
SE Wall
Casita
R-21 Wall (W21.2x6.16)
135
Right
500
60.032
90
SW Wall
Casita
R-21 Wall (W.21.2x6.16)
225
Front
840
0
90
NW Wall
Casita
R-21 Wall (W.21.2x6.16)
315
Left
500
116
90
Roof
Casita
R-38 Roof Attic
8x8
Window
571
8.0
8.0
ATTIC
01 02 03j�04 05 06 07
Name Construction Roof Rise Roof'Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Attic Roof Cons 3 0.1 0.85 No No
e:
WINDOWS
01 02 03
.
M
Name Side of Building Area (ft2)
U -factor
solid Door ^s�� SW Wall 20.1
0.50
01
02
03 in
04
05
06
07
08
09
10
Name
Type
Surface (Orientation-Azimut0:0
Width(ft
)
Height
(ft)
Multiplier
Area
(ft)
U -factor
SHGC
Exterior Shading
2x5
Window
NE Wall (Back -45)
-
--
1
10.0
0.51
0.29
2x5 2
Window
NE Wall (Back -45) �
-
-
1
10.0
0.51
0.29
5x4
Window
NE Wall (Back J5'
--
-
1
20.0
0.51
0.29
8x8
Window
SE Wall (Right:!- ,35)
8.0
8.0
0.938
60.0
0.51
0.29
8x4
Window
NW Wall (L,N" 315)
8.0
4.0
1
32.0
0.51
0.29
6x8
Window
NW WaO(,l?eft-315)
6.0
8.0
1
48.0
0.51
0.29
6x6
Window
NW-WaII'(Left-315)
--
--
1
36.0
0.51 1
0.29
DOORS �w
01 02 03
04
Name Side of Building Area (ft2)
U -factor
solid Door ^s�� SW Wall 20.1
0.50
o®�
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
_a
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Moore Casita - Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
CF*F-01
Page 4 of 8
OVERHANGS AND FINS
01
02 03 04 05 06
07 08 09' 10
11 12 13 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent Flap Ht.
Depth Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
8x8
6.
0.1
6
6 0
0 0
0
0
0
0
0
0
8x4
6
0.1
6
6 0
0 0
0
0
0
0
0
0
6x8
6
0.1
6
6 0
0 0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
0405
06
Construction Name
Surface Type
Construction Type
Framing=W
Total Cavity R -value
Assembly Layers
2x4 Top Cho d of
Cavity /Frame: no insul. /2x4 Top Chrd
Roof Trusst@ 24 in.
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
OAC'✓
none
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
A►
• Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
Ceilings.(below attic)
Wood Framed Ceiling
2 T@ 16 in. 0. C.
R 38
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
o
Cavity/Frame: R-21 /2x6
R-21 Wall (W21.2x6.16)
Exterior Walls
Wood Framed Wall,
2x6'@ 16 in. O.C.
R 21
Exterior Finish: Wood Siding/sheathing/decking
_ter
SLAB FLOORS
01 02 �� 03 04 05 06 07
Name Zone �� Area (ft2) Perimeter (ft) Edge Insula R -value& Depth Carpeted Fraction Heated
Covered Slab Casita v 571 126 None 0.8 No
BUILDING ENVELOPE - HERS VERIFICATION
A.
01 �� 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building EnyelPRe Air Leakage ACH a 50 Pa
Not Required i Not Required Not Required --
WATER.HEATING SYSTEMS
01r 02 03 04
Name ., �� Distribution Type Number of Heaters Solar Fraction (%)
DHW Sys 1 Pipe Insulation, All Lines 1 0.0%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 14:05:09
CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
CFOF-01
Page 5 of 8
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
WATER HEATING -. HERS VERIFICATION
01
02
.03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
�►
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
n/a&�
n/a
n/a
SplitAirCond - Split Eaf conditioning
n/a
HVAC SYSTEMS
01
02
03
04
05
06
07
Efficiency
Heating System .
Cooling System
Name
System Type
EER SEER
Zonally Controlled
®
HERS Verification
Distribution
SplitAirCond - Split Eaf conditioning
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC 1 casital
Other Heating and Cooling System
60
Heating Com ent 1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan 1
571
HVAC - HEATING SYSTEMS
01^ w� 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02 �1
03 04.
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split Eaf conditioning
13 1
17 7
No
No
Cooling Component
system
.®!_
Registration Number: 0�
CA Building Energy Efficiency Standards` - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Moore Casita Calculation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis Input File Name: Moore Casita-Pitchford-14.xml
CFOF-01 _
Page 6 of 8
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge .
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
Required
Supply Duct
Not Required
Not Required Not Required
Name
Type
Duct Leakage
Insulation R -value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located entirely in
conditioned space
Sealed and tested
8
(y!
Conditioned Zone
Conditioned Zone
None
Air.Distribution
System 17hers-dist
��
W9
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03,&W
04
05 O6
Name
Duct Leakage Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
Required
`�6.0
Not Required
Not Required Not Required
HVAC -FAN SYSTEMS _0
01 4020 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required
..-.A,
HVAC FAN SYSTEMS - HERS VERIFICATION
�v
01
( :r 02 03'
Name
VerifiedFanWatt Draw Required Fan Efficiency (Wafts/CFM)
HVAC Fan 1 -hers -fan
Required 0.58
=--a
IAQ (Indoor Air Quality) FANS �.
01
03
04
05
06
��U2�
IAQ Recovery
Name
PIAQ CFM
IAQ Watts/CFM
IAQ Fan Type
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
09 35.71
0.25
Default
0
Required
1w
e®�
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 001)
Project Name: Moore Casita Calculation. Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis . Input File Name: Moore Casita-Pitchford-14.xml
CF1.tF-01
Page 7 of 8 -
COOLING VENTILATION
01
02 03 04 05
Name
Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans HERS Verification
WH Fan 1
61 0.52459 1 Required
®t►
V�
V®
V�
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD
Project Name: Moore Casita Ca culation Date/Time: 14:04, Wed, Oct 08, 2014
Calculation Description: Title 24 Analysis
Input File Name: Moore Casita-Pitchford-14.xml
CF1*F-01
Page.8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signal
Jon d. Scott
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
10/8/2014
Address:
CEA/HERS Certification Identification (If applicable):
77=085 Michigan Drive
City/State ip:
Palm Desert, CA 92211
Phone: `;�►
(7760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT_
I certify the following under penalty of pedury, under the laws of the State of California: oma%
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility forr-to building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Comp it ante are consistent with the i ati vided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency or approval with thi nng p p ca •
Responsible Designer Name:
espon ' Desi e. 09
Robert A. Pitchford
ate Signed:
Company: v
Robert A. Pitchford Design and Drafting
9
Address: �
License:
77-622 Country Club STE O ;e
City/State/Zip:
Phone:
Palm Desert, CA 92211 ,�
(760) 346-2856
ni
to
Registration Number: t@�
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-10-08 14:05:09
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Moore Residence Casita
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Add itior/Alteration
Date
10/8/2014
Project Address
79-731 Arnold Palmer La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
571
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Attic R38 571 New
Wall Wood Framed R 21 2,444 New
Door Opaque Door - no insulation 20 New
Slab Unheated Slab -on -Grade - no insulation 571 Perim = 126' New
Demising Wood Framed R 13 126 New
FENESTRATION I Total Area: 216TGlaing Percentage: 37.8%1New/Altered Averace U -Factor: 0.51
Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status
Rear (NE) 40.0 0.510
0.29 none none Bug Screen New
Right (SE) 60.0 0.510
0.29 6.0 none Bug Screen New
Left (NM 80.0 0.510
0.29 6.0 none Bug Screen New
Left (NW) 36.0 0.510
0.29 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 17.7 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 casita Ducted
Ducted Conditioned 8.0.
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Small Storage Gas 50
0.66 All Pipes Ins New
EnemvPro 6.3 by EnemySoft User Number. 6712
RunCode: 2014-10-08714:05:42 /D:
Pae 11 of 18
� � 1
4
4
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1R
Project Name
Date
Moore Residence Casita
1101812014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum compoient performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form.
§110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirerrents of §110.8(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor.
§150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor.
*§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor.
150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when s ecmed on the CF -1 R Form.
150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or ou:doors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U -factor of 0.58.
2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
greater, is exempt from the maximum U -factor requirement.
150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building rc'ect.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire open ng of the firebox.
§150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six sq -pare inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control aevice.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances ars certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3 c'5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA.
150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c .
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally
wrapped with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 12 of 18
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R
Project Name
Date
Moore Residence Casifa
10/8/2014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, mus- be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requ rements of Standards
Table 120.3-A.
150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment mainteiance, and wind.
§150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other dict -closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal o enin s greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back ribber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
§150.0(m)10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual swelling units shall include
all the following components :
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the soace where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A gas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and A=eptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Bu6ding Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve muirements of 150.0
Residential Lighting Measures:
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance
with TABLE 150.0-A or TABLE 150.0-B as applicable.
150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c)-
§150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an o_it ut frequency - 20 kHz.
§150.0(k)1E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 13G0(c). Night lights shall not
be required to be controlled by vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 13 of 18
r
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 ,of 3 MF -1 R
Project Name
Date
Moore Residence Casita
1101812014
150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k).
150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens s'nall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft' or 100 watts
for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when al
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact CC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumirmire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with s gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions cf items
ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, baconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site sha I comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with the applicable requirements in Sections 110.9, 130.0 130.2, 130.4, 140.7 and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume
no more than five watts of power as determined according to §130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4, 140.6, and 141.0.
§150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
§150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than
20 percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and epiress.
EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 14 of 18
k: I 0 •
4
r
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
oore Residence Casita
Date
10/8/2014
System Name
HVAC 1 casita
Floor Area
571
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,019
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 133
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
La-ent CFM
Sensible
Output perSystem 41,000
15,148
1,121 469
19,937
Total Output Btuh 41,000
0
Output Btuh/s ft 71.8
219
237
Cooling System
01
0
Output perSystem 24,800
5,919
2,374 133
6,483
Total Output Btuh 24,800
0
3,496
0
Total Output Tons 2.1
219
237
Total Output Btuh/s ft 43.4
Total Output s ft/Ton 276.3
21,505
26,894
Air System
CFM perSystem
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Carrier 24ANB724-58CVX040 18,244
3,446
41,000
Airflow cfm/s ft
1.40
Airflow cfm/Ton
387.1
Outside Air %
16.7%
Total Adjusted System Output 18,244
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
3,446 41,000
Aug13 PM Jan 1 AM
Outside Air cfm/s ft 0.23
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
133 cfm
72 OF
64 OF 112 OF 112 OF
f n �
Heating Coil Supply Fan
112 OF
800 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
133 cfm
70 / 61 OF
4 :0,
77/64°F 56/55°F 56/55°F
c O
c
Cooling Coil Supply Fan 56 / 55 OF
800 cfm
58.5% ROOM
70 / 61 OF
a
1 1 1 d I
Energ Pro 6.3 by Energ Soft
User Number: 6712 Run Code: 201410-08T14:05:42 /D:
Page 15 of 18
1� Q 6
•
C.
•
ROOM LOAD SUMMARY
Project Name Date
Moore Residence Casita 10/8/2014
System Name Floor Area
HVAC 1 casita 571
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name =Roonn Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible
Casita Casita 1 1,019 15,148 1,121 1,019 15,148 1,121 469 19,937
PAGE TOTAL
TOTAL`
1,019 15,148
1,121
. 469
19,937
1, 019 15,148
1,121
469
19, 937
Total includes ventilation load for zonal systems.
EnergyPro 6.3 by Ene Soft User Number: 6712 RunCode: 2014-10-08714:05:42 /D: Pae 16 of 18
.ry r a It,
•
ROOM HEATING PEAK LOADS
Project Name
Moore Residence Casita
Date
10/8/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 571.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT of
=
=
=
=
=
=
=
=
=
=
_
_
-
=
_
=
=
-
=
=
_
=
=
-
-
_
_
=
-
=
=
46
Btu/hr
R-38 Roof Attic.
571.0
0.0260
46
683
R-21 Wall (W.21.2x6.16)
2,443.9
0.0690
46
7,757
Low -E NON METALI.51, .39 .
216.0
0.5100
46
5,067
Wood Door
20.1
0.5000
46
462
Slab -On -Grade
perim = 126.0_
0.7300
46
4,231
Items shown with an asterisk (*).denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 571 X
Area
another room
14.00 X 0.266
Height ACH
Rage Total
/60] X
AT
18,201
= 1,736
TOTAL HOURLY HEAT LOSS FOR ROOM 19,937
EnergyPro.6.3 by EnergySott User Number: 6712 RunCode: 201410-08714:05:42 ID: Page 17 of 18.
0
E
a
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project NameDate
Moore Residence Casita
10/8/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area
571.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 0F1
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
(VIO 571.0 X 0.0260
X
56.0 =
831
R-21 Wall (W.21.2x6.16)
(NE) 800.0 X 0.0690
X
29.0 =
1,601
R-21 Wall (W.21.2x6.16)
(SE) 440.0 X 0.0690
X
31.0 =
941
R-21 Wall (W.21.2x6.16)
(SlM 819.9 X 0.0690
X
31.0 =
1,754
Wood Door
(SVV) 20.1 X 0.5000
X
31.0 =
312
R-21 Wall (W.21.2x6.16)
(NAA 384.0 X 0.0690
X
30.2 =
801
X
X
=
X
X
=
X
X
=
Page Total
6,240
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
2x5
(NE) 0.0 X 21.0 +
10.0 x
30.3 =
303
2x5
(NE) 0.0 X 21.0 +
10.0 X
30.3 =
303
5x4
(NE) 0.0 X 21.0 +
20.0 }_
30.3'=
606
8x8
(SE) 60.0 X 21.0 +
0.0 }_
27.6 =
1,258
8x4
(NVV) 0.0 X 21.0 +
32.0 }
30.3 =
969
6x8
(NVI9 0.0 X 21.0 +
48.0 X
30.3 =
1,454
6x6
(NVtq 0.0 X 21.0 +
36.0 X
30.3 =
1,090
X +
_
X +
Page Total
5,983
Internal Gain
Btu/hr
Occupants
1 7 Occupants X 245
Btuh/occ.
=
420
Equipment
571 Floor Area X 0.50
w/sgft
=
974
Infiltration: 1.064
X 0.94 X 36.64 X 42 =
1,531
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
15,148
Latent Gain
Btu/hr
Occupants
1 7 Occupants X 155
Btuh/occ.
=
266
Infiltration: 4,771
X 0.94 X 36.64 X 0.00523 =
856
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
266
EnemyPro 6.3 by EnemySoft
User Number: 6712 RunCode: 2014-10-08714:05:42 /D: