Loading...
9711-052 (PATIO) 79832 Arnold Palmer EJB LICENSED CONTRACTOR DECLARATION ierebNffirm under penalty of perjury that I am licensed under provisions of iapter (commencing with Section 7000) of Division 3 of the Business and DATE ofessionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). (, ) I, as owner of the property, am exclusively contracting with licensed -o contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&RC. for this easo Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700_ of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier f, Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ,I'certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall,forthwith comply with those provisions. rDate: " . 'e 'plicant7577 Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subjec(an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. BUILDING PERMIT VALUATION i ,a a-t►I LOT PERMIT# CONTROL# TRACT 6796 JOB SITE J ADDRESSr t\ 79-8.12 (NOI,I) PAf! ML11 APN 769.41 t-076 OWNER CONTRACTOR / DESIGNER / ENGINEER iS!"' ;/1(:}iS'Arr 1) 1rrj :r> i ll r (?l:ty -. t 1 f...\ Jii♦ .k♦ 79-832 t1RNU.Li) PALMER LA QI tIKI'A CA. 92253 USE OF PERMIT A9 !)<r N it) S.F. PAT T t0 EAiCLCiSt+'it►:; EXTEND (IjkS iANE C3J i l'itjt•.i 'i:riJ.';;'ItiiCl'.i:)►v CBS1.ft IIIIIIIIIIIIIIIIIIIIIIII IE I I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize represerit'atives of this City to enter upon the above-mentioned property for inspection pup. ses. EIPT / . - ' REC /Signature (OwnedAgen ; Date 1 `f_fL3=i '1 Ala t:'t`)►u: 'i`1t11tr"t'lt)N N :I'I. lN f ;11:C: ' DATE ';i.'OTA.1,0111P,, NOW BY 5.453.401,1 00 07 GST ILJ jf&+ Its • W,v10 . 8186.1 .5 +i;i t%AN C1TK.CX F01-3 1.01-t?t!i)_439-3)8 i4b.(a ,-Y)Nn-tvjf(-rit1T,11rt;1; tt11-fi()t).dtstfi(1(! $141 Al • lCN.;ci - 10 10 -&1011', 101-06V-2,11-000 $ i5t,, 1 fMEC1ir\N1CAI. FOi - ' $15AM 1;LW_"Vft1CAJ., F!T 101-000 410-000 PfIri IAINO0`1 t()I -()Nl -a119. (i(t ply5t1 I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize represerit'atives of this City to enter upon the above-mentioned property for inspection pup. ses. EIPT / . - ' REC /Signature (OwnedAgen ; Date 1 `f_fL3=i '1 Ala t:'t`)►u: 'i`1t11tr"t'lt)N N :I'I. lN f ;11:C: ' DATE ';i.'OTA.1,0111P,, NOW BY 5.453.401,1 00 07 GST ILJ jf&+ Its • W,v10 . 8186.1 .5 +i;i f _17 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap_ _ 3 - F.A.U. Framing 7 Compressor Insulation - y (Q - Q Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath - -4 Drywall - Int. Lath Id Final Final — POOLS - SPAS BLOCKWALL APPROVALS Steel Set Backs Electric Bond Footings Main Drain Bond'Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: ' �,�s w��� dv�r2 tatiLST/a�7GIt o SES i07�,YB� ✓��k�bT.S . Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors • :Temp. Use of Power ! Final r` ' Utility Notice (Perm) C `C 91 ` - CITY OF LA QUINTA SUBI IST CONTRAOU ADDRESSIrd�CVi _� OWNER JOB ADDRESS d `' This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. It is the responsibility of the General Contractor or the Owner/Builder to monitor the sub -contractors that are on this list are the same persons performing the work. Any changes to this list must be approved the City of La Quinta Department of Building & Safety 12LI4r to work being performed by a changed sub- contractor. Failure to comply will result in a stoppage of work and/or the voidance of building permit. 'TRADE SUB -CONTRACTOR'S NAME TYPE OF. LICENSE'..:. STATE; CONTRACTOR`S LICENSE NUMBER ' WORKER'S COMP: NAME) NUMBER ON TILE CITY BUSINESS LICENSE . NUMBER? EXP. DATE GRADE/ EXCAVATE A/C -12 PIPELINES: C-34 CONCRETE/ FOUNDATIONS 13loavw�i✓ Csrwst C-8 40ga$O HTt r`�r�D Z''I a9 Oa77(o 8 ASPHALT A. Lf RAMING B 'y -D % 2 8'D gR�7�7P� O;L77 i STEEL/ .STRUCTURAL C-51 MASONRY C-29 PLUMBING K G "Pc,wffi�,b rx, C-36 5-0170-7/ 4 g 9 LATHING C-26 DRYWALL C-9 *0gZL80 CREm f 0,A77B PLASTERING: B C-36�f0 �jZe-7yjQT 0-277(0 HVAC C-20 ELECTRICAL ° ;(General) /MCucAt n Elect; C-10 ?S-2 4110� WAWQ 11r8Y � J a '9 ROOFING C-39 :SHEET METAL C-43 FLOORING `eh.;j.0 TILE C-15 *5647V GLASS/ GLAZING MA&IK t" SZ5 Y-TjQB'/L C-17 (p�(D33� S s 4 _&'S lir-S� IV 5 7 I INSULATION .: C-2 SEWAGE DISP. C-42 -PAINTING/ DECORATING C-33 TILE W#AwsG Ile- C-54 CABINETS/ INSTALLATION C-6 FENCING C-13 LANDSCAPING C-27 POOLS C-53 OTHER U OWNER / BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/ Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations including State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Adminstration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/ Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing 'their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quin 92253 ,(760) 777-7012 FAX (760) 777- 011 d O SIGN RE/DATE PROPERTY ADDRESS q76/ - 052 - PERMIT NUMBER(s) B.G. STRUCTURAL ENGINEERING BRIAN GOTTLIEB - CIVIL ENGINEER - Lic. No. C33047 45-535 Via Corona Indian Wells, CA 92210 (760)568-3553 (760)568-5681 Fax March 4, 1998 Mr. Roger Reimers 69-930 Highway 111 Suite 106 Rancho Mirage, CA 92270 RE: Jackson Residence Remodel Dear Mr. Reimers The following information is presented to clarify our requirements for the foundation plan. On details 7, 8, and 9 on sheet S-3 where the existing footings meet the design requirements a " Simpson " HD2A holdown anchor with " Simpson "SET epoxy can be substituted for the " Simpson "CB or BC column bases. It should be noted that the epoxy requires a special deputy inspector. Please call me at (760) 568-3553 if you would like to discuss this matter. Sincerely, Brian Gottlieb, P.E. cc: file b VALID ONLY IF SIGNED IN RED 11111 III11111 Jill 41 IE TITLE 24 REPORT FOR - 79 -832 Arnold Palmer - La Quinta, CA, 92253 PROJECT DESIGNER: Richard -Nagy -Marlin . 4611 Teller Avenue Newport Beach, CA, 92660 (714) 752-1800 REPORT PREPARED BY: M. F. "Warren" Lavender LAVENDER DESIGN 7755 CHEROKEE TRAIL YUCCA VALLEY, CA 92284 (619) 365-1286 Job Number: 01063 l Date: 5/2.0/1998 The COMPLY 24 computer program has been used to perform the calculations• summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by Gabel Dodd Associates (510) 428-0803. s Table Of Contents.for Title 24 Report CoverPage .................................................. 1 Table of Contents .................................... ............. 2 Form MF 1R Mandatory MA: �: ,� �s �:�,�},;i:.; i' i ...... 3 Form CF --1R Certificate of Compliance ................................. 5 Form C -2R Computer Method Summary (Points) ...... ................. 7 Form,P-2R Point System Summary .......................................... 13 HVAC System Loads Summary .................. ......................... 15 Zone Heating Loads Summary .......................... ................ 17 Zone Cooling Loads Summary 20 Form CF -6R Installation Certificate 23 I 0 rila�Lir�lU1 r 1'1 L:/1.!Vi G:• vIILVI\L1JI ��JC11 UI �J 1Ii--•11.i Pd9d J UI Ld -------------------------------------------------------;------------------- Project Name: Robert Jackson ,Date: 5/20/1998 Documentation: LAVENDER DESIGN ;COMPLY 24 User 1615 ---------------------------------------------------------------------------- NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded.by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES o Sec. 150(a): Minimum R-19 ceiling insulation. o Sec. 150(b) : Loose fill hISLI iat ioll 1117►Iui-1t:I.1ll el s labeled R. -Value. o Sec. 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). * o Sec, 150(d): Minimum R-13 raised floor insulation in framed floors; Minimum R-8 in concrete raised floors. o Sec. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. Enforcement o Sec. 118: Insulation specified or installed meets California Energy Commission quality standards. Indicate Type & form. o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label w/certified U -Value c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. o Sec. 150(f): Special infiltration barrier installed to comply with Sec.. 151 meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces, Decorative Gas Appliances And Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. S MANUA wHY MEASURES CHECKLIST (part 1 of 2) --------.---_.--- Project Name: Robert Jackson MF -1R page 4 of .2 _..__.__.._._..,..._..._ ----------------- ;Date: 5/20/1998 Documentation: LAVENDER DESIGN -------;COMPLY 24 User 1615 - SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM.MEASURES Enforcement o Sec. 110-1.3: HVAC equipment, water.lieaters, showerheads and faucets certified. by the Commission. o Sec. 150(i): Setback thermostat on al -1 applicable heating systems. o Se 50 a ar,r! TT 1. Indirect hot water tanks (99 unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non -recirculation systems, insulated (R-4 or greater. 3. All buried or exposed piping insulated in recirculation sections of hot water system. 4. Cooling system piping below 55 F insulated. 5. Piping insulated between heating source and indirect hot water tank. o Sec. i50(m) Ducts and Fans * 1. Ducts constructed, installed and sealed to comply.with. UMC Sections 1002 and 1004; ducts insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust,_.systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. o.Sec. 114:Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,, no electric resistance heating and no pilot, light.. 2.. System is installed with: a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace,.pool heater, spa heater or household cooking appliance have no continuously burning pilot light. (Exception: Non -electrical cooking app liance with pilot ( 150 Btuh) LIGHTING MEASURES o Sec. 1.50(k). Lighting - 40 lumens/watt: or,greater.for. general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved.