13-1204 (RER) IIIIIIIIIIIIIIIIIIIIIIIII 03
P.O. BOX 1504 IE c&ty/ 4 � VOICE(760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING&SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 12/02/13
Application Number: 13-00001204 Owner:
Property Address: 49452 AVILA DR MAHAFFIE
APN: 646-270-021- - - 49-452 AVILA DR
Application description: REMODEL - RESIDENTIAL LA �`-
PP P QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 55000 D
Contractor: DEC 03 2013
Applicant: Architect or Engineer: JIANNONI DEVELOPMENT & AGEM
83245 BRAID COURT CITY OFL-A QUINTA
f2-- BERMUDA DUNES, CA 9220 FINANCEDEPT.
(760)902-4441
Lic. No. : 979611
---------- -- --------- - --- - ------------ ---- ---- ----- ----- --- - -- ---------- ---- ----- -- -- ----- ----- - -
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations:
Section 7000)of Division 3 of the Business and Professionals Code,and my License is in full force and effect. _ I have and wjll.maintain a certificate of consent to self-insure for workers'compensation,as provided
License Class: B License No.: 979611 for by Section 3700 of the Labor Code,for the performance of the work for which this permit is
issued.
Date: Contractor: _ I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor
Code,for the performance of the work for which this permit is issued. My workers'compensation
WNER-BUILDER DECLARATION insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EX^ PT Policy Number EXEMPT
following reason(Sec.7031.5,Business and Professions Code: Any city or county that requires a permit to I certify that,in the performance of the work for which this permit is issued,I shall not employ any
construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for the person in any manner so as to become subject to the workers'compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that,if I should become subject to the workers'compensation provisions of Section
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or 3700 of the Labor Code,I shall forthwith comply with those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500).: Date: Applicant:
(_1 1,as owner of the property,or my employees with wages as their sole compensation,will do the work,and
the structure is not intended or offered for sale(Sec.7044,Business and Professions Code: The WARNING: FAILURE TO SECUREZ1V111KERS'COMPEr/ATION COVERAGE IS UNLAWFUL,AND SHALL
Contractors'State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRINALTIES ACIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees,provided that the DOLLARS($100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If,however,the building or improvement is sold within SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES.
one year of completion,the owner-builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT
(_1 1,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
7044,Business and Professions Code: The Contractors'State License Law does not apply to an owner of conditions and restrictions set forth on this application.
property who builds or improves thereon,and who contracts for the projects with a contractor(s)licensed 1. Each person upon whose behalf this application is made,each person at whose request and for
pursuant to the Contractors'State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application,
(_I I am exempt under Sec. ,B.&P.C.for this reason the owner,and the applicant,each agrees to,and shall defend,indemnify and hold harmless the City
of La Quinta,its officers,agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit,or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY permit to cancellation.
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all
work for which this permit is issued(Sec.3097,Civ.C.). city and county ordinances and state laws relating to building construction,and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes.
Lender's Name: �?
Date:/Z / Signature(Applicant or Agent):
Lender's Address:
LQPERMIT
fr
Application Number . . . . . 13-00001204
Permit . . . ELECTRICAL 2013
Additional desc .
Permit Fee . . . . 23.83 Plan Check Fee .00
Issue Date Valuation . . . . 0
Expiration Date 5/31/14
Qty Unit Charge Per Extension
1.00 23.8300 LS ELEC FIXTURES, FIRST 20 23.83
----------------------------------------------------------------------------
Permit . . MECHANICAL 2013
Additional desc . .
Permit Fee . . . . 107.26 Plan Check Fee .00
Issue Date . . . . Valuation . . . . 0
Expiration Date 5/31/14
Qty Unit Charge Per Extension
1.00 35.7500 EA MECH FURNACE 35.75
1.00 11.9200 EA MECH APPL REP/ALT 11.92
1.00 35.7500 EA MECH CONDENSER/COMP 35.75
1.00 11.9200 EA MECH VENT FAN 11.92
1.00 11.9200 EA MECH EXHAUST HOOD 11.92
----------------------------------------------------------------------------
Permit . . . PLUMBING 2013
Additional desc . .
Permit Fee . . . . 47.68 Plan Check Fee .00
Issue Date . . . . Valuation 0
Expiration Date 5/31/14
Qty Unit Charge Per Extension
2.00 11.9200 EA PLBG FIXTURE/TRAP 23 .84
1.00 11.9200 EA PLBG WATER INST/ALT/REP 11.92
1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS 11.92
--------------'--------------------------------------------------------------
Permit . . . REMODEL 2013
Additional desc . .
Permit Fee . . . . 134.42 Plan Check Fee .00
Issue Date . . . . Valuation 0
Expiration Date . . , 5/31/14
Qty Unit Charge Per Extension
1.00 48.6200 LS MISC REMODEL, 1ST 100 SF 48.62
4.00 21.4500 EA MISC REMODEL, ADDL 500 SF 85.80
----------------------------------------------------------------------------
Special Notes and Comments
INTERIOR REMODEL UNDER EXISTING ROOF NEW
LQPERMIT
Application Number . . . . 13-00001204
-----------------------------------------------------------=----------------
Special Notes and Comments
KITCHEN ,HVAC, AND 34 SQ. FT. ADDITION.
October 8,2013 2:14:29 PM jjohnson.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . HOURLY PLAN CHECK 147.00
PLAN CHECK, ELECTRICAL 23.83
PLAN CHECK, REMODEL 201.63
PLAN CHECK, MECHANICAL 57.20
PLAN CHECK, PLUMBING 95.34
STRONG MOTION (SMI) - RES 5.50
Fee summary Charged Paid Credited Due
Permit Fee Total 313 .19 .00 .00 313.19
Plan Check Total .00 .00 .00 .00
Other Fee Total 530.50 .00 .00 530.50
Grand Total 843.69 .00 .00 843.69
LQPERMIT
07
`
Bin �` ll ,,,, f� IE
## CiLa
Qty of Quinta'
Building&r Safety Division
Permit.!# P.O. Box 1504, 78-495 Calle Tampico
4La Quinta,CA 92253-(760)777-7012
�j Building Permit Application and Tracking Sheet
Project Address: l�_ i
Z Av � ` Owner's Name: . Ki G
A.P.Number: '��� — C - Address:
Legal Description: 2 Co C9(;. City,ST,Zip:
Contractor: O N Telephone:
Address: Project Description:
City,ST,Zip: X-joe&C V0<1brx T.LI'JN
Telephone: W,.,a,
State Lic.#: City Lic.#.: •
Arch., gr.,Designer:
Address: 2-2` l.�l
City.,ST,Zip: P40_L_ -( Z
� i+ilk i:'r,'�i�..:�:Sv? �j '
Tele hone:-^7 ::;::>:•»:>:>:::<::<•>
P ( [[�,,.,, 22 'z?< <><` ?<;;::.::::.:::::.,.: Construction T e: Occu anc : �7
9�V -4-0 q :.:,:. :':r•;:.;:•;:. :.<:. ::..:: Yp � I� P Y 1`—3
State Lic.# :«.:.::: .>.;;:.<:<•.v..;:.,,.:::.;:::>:•:::::.:;:<•:;:<•
... Project type(circle one): Ne,7=Alter Repair Demo
.::::....:::.::......:....::.:...:...::.....
Name of Contact Person:�� �. Sq.Ft.: #Stories: #Units:
Telephone#of Contact Person: �4(o �t9-fl 2. Estimated Value of Project: �i (C> r�t,
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal Req'd Rec'd TRACKING PERMIT FEES
Plan Sets Plan Check submitted a Item Amount
Structural Calcs. Reviewed,rcadi4or corrections 01 Zl Plan Check Deposit
Truss Calu. Called Contact Pc Plan Check Balance.
Title 24 Cales. Plans picked up Ju-1.. J -A tj,,j()hJ j„ Z Construction
Flood plain plan Plans resubmitted )012,4 Mechanical
Grading plan 2""Review,ready for correctio /issue Electrical
Subeontactor List Called Contact Person Plumbing •.
Grant Deed Plans picked up S.M.1. Alk
H.O.A.Approval Plans resubmitted Grading
IN HOUSE:- 'rd Reyiew,ready for corrections/issue 'Developer Impact Fee
—Planning p al ailed onla:cf�enon A
Pub.Wks.Appr Date of permit issue
School Fees
Total Permit Fees SEP 119 201
10(� b 0(5 R l0 9/3���'
CIN OF.LA INTA
lO (,I r" k COMMUNITY DEVELOPMENT
CITY- OF LA QUINTA_SUB-CONTR CTOR LI T ' .
JOB ADDRESS % 7"l�S� Ij til�I - ,n� PERMIT NUMBER /3r'/p�t7 OWNER' BUILDER �z/� 1P(H laDr� P4
This form shall be costedon the job with the Building Inspection Card-at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any-changes to this list must be approved by the Building Division prior to cornmencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be colnple.ted by applicant. "On File" is not an acceptable response.
77T777777717: 777
Trade Classification -:. -:::::::;:: .<:.,; . :
Cla sific
/ s alio :::>...: ;.. .:
State.Contractor s License
::
.. .:-:.-..;r:. ::.. . .'.:, '-•:Work'e�s.Con-I erlsaLon•:Insurance:�':;:• •...�:;:-;.•.� :.;;:-:-. .'�•-. City:Biisrie�s
Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date
(e.g.A. B, C-8) (xxxxxx) (:ax/xx/xx) (e.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) (xxxx) (xx/xx/xx)
EARTHWORK (C712)
CONCRETE(Q-8)':%' L
h (0/)/." u P, 0 3/3 i ' r 7n�PS C lt�l CO . u9 3 05 q 5e i
FRAMING:(0-5) ':::` S�r� ��U —I 7 4� LL
LJ l / 3 /
STRUCT.`STEEL'jC-51)
(MASONRY(C-29) / , S Sb�/ "'� l
PLUMBING(C-36)' � '-. �� _ I9 � 111 y1,111q
f'1<LIn � Cad 3 ' �1�1 `% >,u.� 7lv d �� Ia-) 1 zAS-
AA
LATH;PLASTER IC=3. I I G >r11 Ff/ f i b y/� / I f P co, c5t 0 btg S Z Z / 3
DRYWALL(C-9) .., . obD 64
7 S / l3a q Ltand
HVAC (C720)` ...>::.. : �Y ,'� 11/b /
966
T��vcJo�1 oos)3 y _573 83
ELECTRICAL.(C=10) ;` . : t. I (Al �d r �!s —I o 7q$ 1 �� 3° J �t1) ti / s ,0(bell�a
RQQFING:IC 39) ':::' I 17U ut I� rl 3 y 7 "p 131
.SHEET.METAL(C43)
FLOORING (C."! '313)�nct� ��ba I { ,�c!I ' C-15 '�i 3 3) / /11 ! 1'r\5 . CO
n ln1r� Cvr� o7 0-13 ? is I y7�� 30 /
GLAZING (C-17);.' ..:.;. /F�rh S }0 Y Il-f f Po/ A 1 SS (_ 17 5-10371
INSULATION -2).' .::.-
SEWAGE-DISP '{C-421
PAINTING (C-7.33) ': .f?j �nB t:/\ C�-1 (r�3 3a-� 30 a8 -- l
f I 3 /o
CERAMIC TICE(C-54)
CABINETS (C-6)
ej 1 l / a , 13-111 y
FENCING (C713)
LANDSCAPING (C=27) ;
pnrn 1r-jai
IIIIIIIIVIIIIIIVIIIIIII 09
IE
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
A Residence Remodel
49-452 Avila
La Quinta, CA 92253
Project Designer:
Andrzej W. Weber, Architect
2278 Via Alba
Palm Desert, CA 92260
(760) 340-3022
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
Job Number: RECEIVED
OCT 2 3 2013 1
Date: CIIY OF LA Q
UINTA
10/23/2013 COMMUNITY DE L PMEN7-
The EnergyPro computer program has been used to perform the calculations summ ize�iin'*1MO&
of r -ort.Tifsd'r a royal and is
�p pauthorized by the California Energy Commission for use with both the Residential ndNo �n�i lignprg5F,ffj�re7n y tandards.
This program developed by EnergySoft,LL —www, (t.c6"o VrEDU�CF'
En;rgyPro 5.1 6 Ener Soft User Number.6712 RunCode:2013-10-23T10:36:33 ID: UN I
a :x DATE
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R Certificate of Compliance 3
Form MF-1 R Mandatory Measures Summary 9
CIT} ®F LA QUIIVT,q
BUILDING & S
�P�®VAFEEFT.
ED
OR CONSTRUCTION
EnergyPro 5.1 by EnergySoft Job Number: ID: DATE User Number:671
Y
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R
Project Name Building Type m Single Family ❑Addition Alone Date
A Residence Remodel ❑Multi Family m Existing+Addition/Alteration 10/23/2013
Project Address California Energy Climate Zone Total Cond.Floor Area Addition #of Stories
49-452 Avila La Quinta CA Climate Zone 15 2,055 34 1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
Roof Wood Framed Attic R-19 2,021 Existing
Wall Wood Framed R-13 1,241 Altered
Door Opaque Door None 48 Existing
Slab Unheated Slab-on-Grade None 2,021 Perim=180' Existing
Roof Wood Framed Attic R-30 34 New
Wall Wood Framed R-13 113 New
Slab Unheated Slab-on-Grade None 34 Perim=16' New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Left(N) 50.3 1.280 0.80 none none Bug Screen Existing
Rear(E) 54.0 1.280 0.80 none none Bug Screen Existing
Rear(E) 160.0 0.400 0.35 none none Bug Screen Altered
Rear(E) 3.5 1.280 0.80 none none Bug Screen Existing
Right(S) 39.5 0.400 0.35 none none Bug Screen Altered
Right(S) 28.1 1.280 0.80 none none Bug Screen Removed
Right(S) 24.0 0.400 0.35 none none Bug Screen New
Right(S) 52.0 1.280 0.80 none none Bug Screen Existing
Front(IM 3.5 1.280 0.80 none none Bug Screen Existing
Front(W) 82.7 0.400 0.35 none none Bug Screen New
Front(IM 57.5 1.280 0.80 none none Bug Screen Removed
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80%AFUE Packaged Air Condition. 11.0 SEER Setback Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
Existing HVAC Ducted Ducted Attic,Ceiling Ins, vented 4.2 Existing
WATER HEATING CITY OF
Qty. Type Gallons Min. Eff Distri-utionNi,r, QUIto Tus
T1'D
ivy rFi(jCT
DATF
EnergyPro 5.1 by Ener Soft User Number:6712 RunCode:2013-10-23T40• A33 RV fage 3 of 11
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R
• Project Name Building Type ®Single Family ❑Addition Alone Date
A Residence Remodel 1 ❑Multi Family m Existing+Addition/Alteration 11012312013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist.These items require special written
justification and documentation,and special verification to be used with the performance approach.The enforcement agency
determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
CITY OF ZF
_& DEPT,
�A r�I%
• o
FOR CONS t�
EnerqvPro 5.1 by EnerqySoft User Number:6712 Run Code:2013-10-23110:36:33 ID: Pa e 4 of 11
DATE�8Y
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R
• Project Name Building Type m Single Family ❑Addition Alone Date
A Residence Remodel ❑Multi Family m Existing+Addition/Alteration 10/23/201
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ftZ- r
Space Heating 13.32 9.18 4.14
Space Cooling 179.43 146.00 33.43
Fans 37.16 30.08 7.08
Domestic Hot Water 17.04 17.04 0.00
Pumps 0.00 0.00 0.00
Totals 246.96 202.31 44.65
Percent Better Than Standard: 18.1%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
.Fenestration
Building Front Orientation: (tM 270 deg Ext.Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (tM 430 86
Fuel Available at Site: Natural Gas (N) 563 50
Raised Floor Area: 0 (E) 338 218
Slab on Grade Area: 2,055 (S) 540 116
Average Ceiling Height: 9.5 Roof 2,055 0
Fenestration Average U-Factor: 0.71 TOTAL: 470
Average SHGC: 0.51 Fenestration/CFA Ratio: 22.8%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and comple e.
Documentation Author
Company Scott Design and Title 24,Inc, 102312013
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert,Ca 92211 Phone (760)200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing,verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) CITE/
Company Andrzej W.Weber,Architect =& s.4
UANTA
Address 2278 Via Alba Name Andtzej Weber BUILD71 ,
City/State/Zip Palm Desert, CA 92260 Phone (760)340-3022 ¢ � Sig`eense# Date
I
Ener Pro 5.1 by Ener Soft User Number.,6712 RunCode:2013-10-23710:36:33 ID: I Page 5 of 11
1 -LL-- J
BY
i
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R
Project Name Building Type m Single Family ❑Addition Alone Date
A Residence Remodel ❑Multi Family m Existing+Addition/Alteration 11012312013
OPAQUE SURFACE DETAILS r
Surface U- Insulation Joint Appendix
Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 1 4 Location/Comments
Roof 2,021 0.049 R-19 0 20 ExisM 4.2.1-A4 Exisitng Residence
Wall 490 0.102 R-13 0 90 Altered 4.3.1-A3 E=4.3.1-A2) Exisitng Residence
Wall 86 0.102 R-13 90 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitng Residence
Wall 35 0.102 R-13 106 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitng Residence
Wall 425 0.102 R-13 180 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitnq Residence
Wall 35 0.102 R-13 254 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitng Residence
Wall 172 0.102 R-13 270 90 Altered 4.3.1-A3(E=4.3.1-A2) Exisitng Residence
Door 48 1.450 None 270 90 Existing 4.5.1-A1 Exisitng Residence
Slab 2,021 0.730 None 0 180 Existing 4.4.7-A1 Exisitng Residence+
Roof 34 0.031 R-30 0 0 New 4.2.1-A20 Addition
Wall 23 0.102 R-13 0 90 New 4.3.1-A3 Addition
Wall 90 0.102 R-13 270 90 New 4.3.1-A3 Addition
Slab 34 0.730 None 0 180 New 4.4.7-A 1 Addition
FENESTRATION SURFACE DETAILS
ID Type Area U-Factor. SHGC Azm Status Glazing Type Location/Comments-
1 Window 50.3 1.280 Default 0.80 Default 0 Existing Single Non-Metal Clear Exisitng Residence
2 Window 54.0 1.280 Default 0.80 Default 90 Existing Single Non-Metal Clear Exisitng Residence
3 Window 80.0 0.400 NFRC 0.35 NFRC 90 Altered Double Non Metal Tinted Exisitng Residence
4 Existing 1.280 Default 0.80 Default Single Non-Metal Clear pre-altered for above
5 Window 80.0 0.400 NFRC 0.35 NFRC 90 Altered Double Non Metal Tinted Exisitng Residence
6 Existing 1.280 Default 0.80 Default Single Non-Metal Clear pre-altered for above
r` 7 Window 3.5 1.280 Default 0.80 Default 106 Existing Single Non-Metal Clear Exisitng Residence
8 Window 2.0 . 0.400 NFRC 0.35 NFRC 180 Altered Double Non Metal Tinted Exisitng Residence
9 Existing 1.280 Default 0.80 Default I Single Non-Metal Clear pre-aitered for above
` 10 Window 2.0 1.280 Default 0.80 Default 180 Removed I Single Non-Metal Clear Exisitng Residence
11 Window 2.0 0.400 NFRC 0.35 NFRC 180 Altered Double Non Metal Tinted Exisitng Residence
12 Existing 1.280 Default 0.80 Default Single Non-Metal Clear pre-altered for above
13 Window 6.0 1.280 Default 0.80 Default 180 Removed Single Non-Metal Clear Exisitng Residence
14 Window 12.0 0.400 NFRC 0.35 NFRC 180 New Double Non Metal Tinted Exisitng Residence
15 Window 3.5 1.280 Default 0.80 Default 180 Existing Single Non-Metal Clear Exisitng Residence
16 . Window 45.0 1.280 Default 0.80 Default 186 Existing Single Non-Metal Clear Exisitng Residence
(1) LI-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value ,
2 SHGC Type: 116-13=Default Table from Standards,NFRC=Labeled Value 1
EXTERIOR SHADING DETAILS
Window Ove hanq Left Fin Ri ht Fin
Len Ht tID Exterior Shade Type SHGC H t Wd
1 Bug Screen 0.76
2 Bug Screen 0.76 t
3 Bug Screen 0.76 '•
4 Bug Screen 0.76
5 Bug Screen 0.76
6 Buq Screen 0.76
7 Bug Screen 0.76 `
8 Bug Screen 0.76
9 Bug Screen 0.76
10 Bug Screen 0.76
11 Bug Screen 0.76
12 Bug Screen 0.76 1. 1 ,�.1 r-_1 A I ITA I
13 Bug Screen 0.76 RI Of f 1 -_W o y _
14 Bu Screen 0.76 ( nr `'
15 Bug Screen 0.76
16 Bug Screen 0.76
3
74 Energypro 5.1 by Ener Soft User Number-6712 RunCode:2013-10-23T10:36 0 - lD:__ RV Pa' e 6 of 11
,
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 r CF-1 R
• Project Name Building Type m Single Family ❑Addition Alone Date
A Residence Remodel ❑ Multi Family 0 Existing+Addition/Alteration 0/23/2013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments
17 Window 3.5 1.280 Default 0.80 Default 180 Existing Single Non-Metal Clear Exisitng Residence
18 Window 20.1 1.280 Default 0.80 Default 180 Removed Single Non-Metal Clear Exisitng Residence
19 Window 12.0 0.400 NFRC 0.35 NFRC 180 New � Double Non Metal Tinted Exisitng Residence
20 Window 35.5 0.400 NFRC 0.35 NFRC 180 Altered Double Non Metal Tinted Exisitng Residence
21 Existing 1.280 Default 0.80 Default I Single Non-Metal Clear pre-altered for above
22 Window 3.5 1.280 Default 0.80 Default1270
Existing Single Non-Metal Clear Exisitng Residence
23 Window 15.0 0.400 NFRC 0.35 NFRCNew Double Non Metal Tinted Exisitng Residence
24 Window 30.0 1.286 Default 0.80 DefaultRemoved Single Non-Metal Clear Exisitng Residence
25 Window 40.2 0.400 NFRC 0.35 NFRCNew Double Non Metal Tinted Exisitng Residence
26 Window 27.5 1.280 Default 0.80 DefaultRemoved Single Non-Metal Clear Exisitng Residence
27 Window 27.5 0.400 NFRC 0.35 NFRC 270 New Double Non Metal Tinted Addition
(1) Q-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value
2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hanq Left Fin Ri ht Fin
ID Exterior Shade Type SHGC H t Wd Len Hot LExt REA Dist Len Hat Dist Len H t
17 Bug Screen 0.76
18 Bug Screen 0.76
19 Bug Screen 0.76
20 Bug Screen 0.76
21 Bug Screen 0.76
22 Bug Screen 0.76
23 Bug Screen 0.76
24 Bug Screen 0.76
25 Bug Screen 0.76
26 Bug Screen 0.76
27 Bug Screen 0.76 i "�/ 1 ir-
oLl _�It\iJ F
\ •tet;--�--. , -
,`� fes► ,,.�,
OR
• o .
Ener Pro 5.1 b Ener Soft User Number:6712 RunCode:2013-10-23T1 b:361 -'-'ID. C Pe e 7 of 11
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF-1 R
• Project Name Building Type ® Single Family ❑Addition Alone Date
A Residence Remodel ❑ Multi Family ® Existing+Addition/Alteration 10/23/201
BUILDING ZONE INFORMATION
Floor Area ft
System Name Zone Name New Existin Altered Removed Volume Year Built
Existing HVAC Exisitng Residence 2,021 19,200 1985
Addition 34 306
Totals 1 341 Z0211 01 01 1
HVAC SYSTEMS
System Name Qty. Heating Type__ Min. Eff. Coolin Type Min. Eff. Thermostat Type Status
Existing HVAC 1 Central Furnace 80%AFUE Packaged Air Condition 11.0 SEER Setback Existing
HVAC DISTRIBUTION
Duct Ducts
System Name Heating Cooling Duct Location R-Value Tested? Status
Existing HVAC Ducted Ducted Attic, Ceiling Ins,vented 4.2 ❑ Existing
WATER HEATING SYSTEMS
Ext.
Rated Tank Energy Standby Tank
Input Cap. Factor Loss or Insul.R-
S stem Name Qty. Type Distribution (Btu h) al or RE Pilot Value Status
Existing State DWH 1 Small Gas No Pipe Insulation 40,0001 40 0.56 n/a n/a Existing
MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING
Hot Water Piping Length
fto
.6
� ip. Insul.
Control aty. HP Plenum Outside Buried a $.ste aWa 'e ,Le• th t piaMr Thick.
❑ r rr� t
pUI IN t
❑ I /1 A
❑ r r
Ener Pro 5.1 by EnergySoft User Number:6712 RunCode:2013-10-23T10 ID: Pa•e 8 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R
Project Name Date
A Residence Remodel 11012312013
NOTE:Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD,or CF-
1 R-ALT Form)shall supersede the items marked with an asterisk(*)below.This Mandatory Measures Summary shall be incorporated
into the permit documents,and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
§116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products(except field-fabricated windows)have a label listing the certified LI-Factor,certified Solar Heat Gain
Coefficient SHGC ,and infiltration that meets the requirements of 10-111(a).
117:Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulatinq Material. Indicate type and include on CF-6R Form.
§118(1):The thermal emittance and solar"reflectance values of the cool roofing material meets the requirements of§118(1)when the
installation of a Cool Roof is specified on the CF-1 R Form.
.*§l 50 a :Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor.
150(b):Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
150(c):Minimum R-13 insulation in wood-frame wall orequivalent U-factor.
*§1 50 d :Minimum R-1 3 insulation in raised wood frame floor orequivalent LI-factor.
150(f):Air retarding wrap is tested labeled,and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form.
§150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150(e)IA:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is
equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device.
-x• §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the
outside of the building,are prohibited. f
!,Space Conditioning,Water Heating and Plumbing System Measures: `
§110-§113:HVAC equipment,water heaters,showerheads,faucets and all other regulated appliances are certified by the Energy
. Commission.
§113(c)5:'Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve,backflow prevention,pump isolation valve,and recirculation loop connection requirements of§113(c)5.
§115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances
'(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and
spa heaters.
150(h):Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACOA.
150(i):Heating systems are equipped with thermostats that meet the setback requirements of Section 112 c .
§150(j)1 A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater. '
§1500)1 B:Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§1506)2:First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of
recirculating sections of hot water�i es are insulated per Standards Table 150-13.
§150(j)2:Cooling system piping(suction,chilled water,or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2:Pipe insulation for steam hydronic heating systems or hot water systems>15 psi met e�tre'[n nt of tN4Tj e
123A
150 '3A:Insulation is protected from damage,includingthat due to sunlight moisture e ui aiR e41a d i DEPT.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines'includes a vapor etardan%' dh_Zl,s e 'r ED
-conditioned space.
"§150(j)4:Solar water-heating systems and/or collectors are certified b the Solar Ratin aid Certification Corporation.
DATES BY
• EnergyPro 5.1 by EnergySoR User Number:6712 RunCode:2013-10-23T10:36:33 ID: Page 9 of 11
}
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name Date
A Residence Remodel 11012312013
§150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections
601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the
applicable requirements of UL 181,UL 181A,or UL 181 B or aerosol sealant that meets the requirements of UL 723.If mastic or tape is
used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used
§150(m)1:Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed
sheet metal,duct board or flexible duct shall not be used for conveying conditioned air.Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
§150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated
dampers.
§150(m)9: Insulation shall be protected from damage,including that due to sunlight,moisture,equipment maintenance,and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150(m)10:Flexible ducts cannot have porous inner cores.
§150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation
.required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency
Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and
shall not use electric resistance heating ora pilot li ht.
§114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction
and return lines,or built-up connections for future solar heating.
§114(b)2:Outdoor ools ors as that have a heat pump or as heater shall have a cover.
§114(b)3:Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 :Residential pool systems orequipment meet the pump sizing,flow rate,piping,filters,and valve requirements of§150
Residential Lighting Measures:
§150(k)1:High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacyluminaire asspecified b 150 k 2.
§150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d).
-§150(k)4:Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5:Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a
medium screw-base socket.
150(k)6:Lighting integral to exhaust fans,in rooms other than kitchens,shall meet the applicable re uirements of§150(k).
150(k)7:All switching devices and controls shall meet the requirements of§150(k)7.
§150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION:Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor,dimmer,energy management system (EMCS),or a multi-scene programmable control system;and all permanently installed
Auminaries in garages,laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9:Permanently installed lighting that is internal to cabinets shall use no more than 20 yva�s�of po errpe im ar o0 0
illuminated cabinet. I r T r
ninj
BUILDING & SAFETY DEPT.
/APPROVED
FOR CONSTRUCTION
SEnergyPro 5.1 by EnergySoff User Number.6712 RunCode:2013-10-23710:36:33 ID: Page 10 of 11
BY -
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
41 Project Name Date
A Residence Remodel 11012312013
§150(k)10:Permanently installed luminaires in bathrooms,attached and detached garages,laundry rooms,closets and utility rooms
shall be high efficacy.
EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of§119.
EXCEPTION 2:Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11:Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages, laundry rooms,
closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1:Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual-
on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with§150 k 11.
§150(k)12:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters
Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13:Luminaires providing outdoor lighting,including lighting for private patios in low-rise residential buildings with four or more
:dwelling units,entrances,balconies,and porches,which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy.EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch,a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management
control system(EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor
luminaires used to comply with Exceptions to§150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3:Permanently installed
luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket,and consume no
more than five watts of power as determined according to§130,d).
§150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130,131, 134,and 146.
§150(k)16:Permanently installed lighting in the enclosed,non-dwelling spaces of low-rise residential buildings with four or more
_dwelling units shall be high efficacy luminaires. EXCEPTION:Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
EnergyPro 5.1 by EnergySoft User Number:6712 RunCode:2013-10-23710:36:33 ID: Page 11 of 11