Loading...
13-1204 (RER) IIIIIIIIIIIIIIIIIIIIIIIII 03 P.O. BOX 1504 IE c&ty/ 4 � VOICE(760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING&SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 12/02/13 Application Number: 13-00001204 Owner: Property Address: 49452 AVILA DR MAHAFFIE APN: 646-270-021- - - 49-452 AVILA DR Application description: REMODEL - RESIDENTIAL LA �`- PP P QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 55000 D Contractor: DEC 03 2013 Applicant: Architect or Engineer: JIANNONI DEVELOPMENT & AGEM 83245 BRAID COURT CITY OFL-A QUINTA f2-- BERMUDA DUNES, CA 9220 FINANCEDEPT. (760)902-4441 Lic. No. : 979611 ---------- -- --------- - --- - ------------ ---- ---- ----- ----- --- - -- ---------- ---- ----- -- -- ----- ----- - - LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000)of Division 3 of the Business and Professionals Code,and my License is in full force and effect. _ I have and wjll.maintain a certificate of consent to self-insure for workers'compensation,as provided License Class: B License No.: 979611 for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Date: Contractor: _ I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. My workers'compensation WNER-BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EX^ PT Policy Number EXEMPT following reason(Sec.7031.5,Business and Professions Code: Any city or county that requires a permit to I certify that,in the performance of the work for which this permit is issued,I shall not employ any construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for the person in any manner so as to become subject to the workers'compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that,if I should become subject to the workers'compensation provisions of Section License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or 3700 of the Labor Code,I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500).: Date: Applicant: (_1 1,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business and Professions Code: The WARNING: FAILURE TO SECUREZ1V111KERS'COMPEr/ATION COVERAGE IS UNLAWFUL,AND SHALL Contractors'State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRINALTIES ACIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees,provided that the DOLLARS($100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If,however,the building or improvement is sold within SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES. one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_1 1,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044,Business and Professions Code: The Contractors'State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon,and who contracts for the projects with a contractor(s)licensed 1. Each person upon whose behalf this application is made,each person at whose request and for pursuant to the Contractors'State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_I I am exempt under Sec. ,B.&P.C.for this reason the owner,and the applicant,each agrees to,and shall defend,indemnify and hold harmless the City of La Quinta,its officers,agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued(Sec.3097,Civ.C.). city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Lender's Name: �? Date:/Z / Signature(Applicant or Agent): Lender's Address: LQPERMIT fr Application Number . . . . . 13-00001204 Permit . . . ELECTRICAL 2013 Additional desc . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 5/31/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 23.83 ---------------------------------------------------------------------------- Permit . . MECHANICAL 2013 Additional desc . . Permit Fee . . . . 107.26 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/31/14 Qty Unit Charge Per Extension 1.00 35.7500 EA MECH FURNACE 35.75 1.00 11.9200 EA MECH APPL REP/ALT 11.92 1.00 35.7500 EA MECH CONDENSER/COMP 35.75 1.00 11.9200 EA MECH VENT FAN 11.92 1.00 11.9200 EA MECH EXHAUST HOOD 11.92 ---------------------------------------------------------------------------- Permit . . . PLUMBING 2013 Additional desc . . Permit Fee . . . . 47.68 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 5/31/14 Qty Unit Charge Per Extension 2.00 11.9200 EA PLBG FIXTURE/TRAP 23 .84 1.00 11.9200 EA PLBG WATER INST/ALT/REP 11.92 1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS 11.92 --------------'-------------------------------------------------------------- Permit . . . REMODEL 2013 Additional desc . . Permit Fee . . . . 134.42 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date . . , 5/31/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC REMODEL, 1ST 100 SF 48.62 4.00 21.4500 EA MISC REMODEL, ADDL 500 SF 85.80 ---------------------------------------------------------------------------- Special Notes and Comments INTERIOR REMODEL UNDER EXISTING ROOF NEW LQPERMIT Application Number . . . . 13-00001204 -----------------------------------------------------------=---------------- Special Notes and Comments KITCHEN ,HVAC, AND 34 SQ. FT. ADDITION. October 8,2013 2:14:29 PM jjohnson. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . HOURLY PLAN CHECK 147.00 PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, REMODEL 201.63 PLAN CHECK, MECHANICAL 57.20 PLAN CHECK, PLUMBING 95.34 STRONG MOTION (SMI) - RES 5.50 Fee summary Charged Paid Credited Due Permit Fee Total 313 .19 .00 .00 313.19 Plan Check Total .00 .00 .00 .00 Other Fee Total 530.50 .00 .00 530.50 Grand Total 843.69 .00 .00 843.69 LQPERMIT 07 ` Bin �` ll ,,,, f� IE ## CiLa Qty of Quinta' Building&r Safety Division Permit.!# P.O. Box 1504, 78-495 Calle Tampico 4La Quinta,CA 92253-(760)777-7012 �j Building Permit Application and Tracking Sheet Project Address: l�_ i Z Av � ` Owner's Name: . Ki G A.P.Number: '��� — C - Address: Legal Description: 2 Co C9(;. City,ST,Zip: Contractor: O N Telephone: Address: Project Description: City,ST,Zip: X-joe&C V0<1brx T.LI'JN Telephone: W,.,a, State Lic.#: City Lic.#.: • Arch., gr.,Designer: Address: 2-2` l.�l City.,ST,Zip: P40_L_ -( Z � i+ilk i:'r,'�i�..:�:Sv? �j ' Tele hone:-^7 ::;::>:•»:>:>:::<::<•> P ( [[�,,.,, 22 'z?< <><` ?<;;::.::::.:::::.,.: Construction T e: Occu anc : �7 9�V -4-0 q :.:,:. :':r•;:.;:•;:. :.<:. ::..:: Yp � I� P Y 1`—3 State Lic.# :«.:.::: .>.;;:.<:<•.v..;:.,,.:::.;:::>:•:::::.:;:<•:;:<• ... Project type(circle one): Ne,7=Alter Repair Demo .::::....:::.::......:....::.:...:...::..... Name of Contact Person:�� �. Sq.Ft.: #Stories: #Units: Telephone#of Contact Person: �4(o �t9-fl 2. Estimated Value of Project: �i (C> r�t, APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted a Item Amount Structural Calcs. Reviewed,rcadi4or corrections 01 Zl Plan Check Deposit Truss Calu. Called Contact Pc Plan Check Balance. Title 24 Cales. Plans picked up Ju-1.. J -A tj,,j()hJ j„ Z Construction Flood plain plan Plans resubmitted )012,4 Mechanical Grading plan 2""Review,ready for correctio /issue Electrical Subeontactor List Called Contact Person Plumbing •. Grant Deed Plans picked up S.M.1. Alk H.O.A.Approval Plans resubmitted Grading IN HOUSE:- 'rd Reyiew,ready for corrections/issue 'Developer Impact Fee —Planning p al ailed onla:cf�enon A Pub.Wks.Appr Date of permit issue School Fees Total Permit Fees SEP 119 201 10(� b 0(5 R l0 9/3���' CIN OF.LA INTA lO (,I r" k COMMUNITY DEVELOPMENT CITY- OF LA QUINTA_SUB-CONTR CTOR LI T ' . JOB ADDRESS % 7"l�S� Ij til�I - ,n� PERMIT NUMBER /3r'/p�t7 OWNER' BUILDER �z/� 1P(H laDr� P4 This form shall be costedon the job with the Building Inspection Card-at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any-changes to this list must be approved by the Building Division prior to cornmencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be colnple.ted by applicant. "On File" is not an acceptable response. 77T777777717: 777 Trade Classification -:. -:::::::;:: .<:.,; . : Cla sific / s alio :::>...: ;.. .: State.Contractor s License :: .. .:-:.-..;r:. ::.. . .'.:, '-•:Work'e�s.Con-I erlsaLon•:Insurance:�':;:• •...�:;:-;.•.� :.;;:-:-. .'�•-. City:Biisrie�s Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date (e.g.A. B, C-8) (xxxxxx) (:ax/xx/xx) (e.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) (xxxx) (xx/xx/xx) EARTHWORK (C712) CONCRETE(Q-8)':%' L h (0/)/." u P, 0 3/3 i ' r 7n�PS C lt�l CO . u9 3 05 q 5e i FRAMING:(0-5) ':::` S�r� ��U —I 7 4� LL LJ l / 3 / STRUCT.`STEEL'jC-51) (MASONRY(C-29) / , S Sb�/ "'� l PLUMBING(C-36)' � '-. �� _ I9 � 111 y1,111q f'1<LIn � Cad 3 ' �1�1 `% >,u.� 7lv d �� Ia-) 1 zAS- AA LATH;PLASTER IC=3. I I G >r11 Ff/ f i b y/� / I f P co, c5t 0 btg S Z Z / 3 DRYWALL(C-9) .., . obD 64 7 S / l3a q Ltand HVAC (C720)` ...>::.. : �Y ,'� 11/b / 966 T��vcJo�1 oos)3 y _573 83 ELECTRICAL.(C=10) ;` . : t. I (Al �d r �!s —I o 7q$ 1 �� 3° J �t1) ti / s ,0(bell�a RQQFING:IC 39) ':::' I 17U ut I� rl 3 y 7 "p 131 .SHEET.METAL(C43) FLOORING (C."! '313)�nct� ��ba I { ,�c!I ' C-15 '�i 3 3) / /11 ! 1'r\5 . CO n ln1r� Cvr� o7 0-13 ? is I y7�� 30 / GLAZING (C-17);.' ..:.;. /F�rh S }0 Y Il-f f Po/ A 1 SS (_ 17 5-10371 INSULATION -2).' .::.- SEWAGE-DISP '{C-421 PAINTING (C-7.33) ': .f?j �nB t:/\ C�-1 (r�3 3a-� 30 a8 -- l f I 3 /o CERAMIC TICE(C-54) CABINETS (C-6) ej 1 l / a , 13-111 y FENCING (C713) LANDSCAPING (C=27) ; pnrn 1r-jai IIIIIIIIVIIIIIIVIIIIIII 09 IE BUILDING ENERGY ANALYSIS REPORT PROJECT: A Residence Remodel 49-452 Avila La Quinta, CA 92253 Project Designer: Andrzej W. Weber, Architect 2278 Via Alba Palm Desert, CA 92260 (760) 340-3022 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: RECEIVED OCT 2 3 2013 1 Date: CIIY OF LA Q UINTA 10/23/2013 COMMUNITY DE L PMEN7- The EnergyPro computer program has been used to perform the calculations summ ize�iin'*1MO& of r -ort.Tifsd'r a royal and is �p pauthorized by the California Energy Commission for use with both the Residential ndNo �n�i lignprg5F,ffj�re7n y tandards. This program developed by EnergySoft,LL —www, (t.c6"o VrEDU�CF' En;rgyPro 5.1 6 Ener Soft User Number.6712 RunCode:2013-10-23T10:36:33 ID: UN I a :x DATE TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 9 CIT} ®F LA QUIIVT,q BUILDING & S �P�®VAFEEFT. ED OR CONSTRUCTION EnergyPro 5.1 by EnergySoft Job Number: ID: DATE User Number:671 Y PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date A Residence Remodel ❑Multi Family m Existing+Addition/Alteration 10/23/2013 Project Address California Energy Climate Zone Total Cond.Floor Area Addition #of Stories 49-452 Avila La Quinta CA Climate Zone 15 2,055 34 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 2,021 Existing Wall Wood Framed R-13 1,241 Altered Door Opaque Door None 48 Existing Slab Unheated Slab-on-Grade None 2,021 Perim=180' Existing Roof Wood Framed Attic R-30 34 New Wall Wood Framed R-13 113 New Slab Unheated Slab-on-Grade None 34 Perim=16' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left(N) 50.3 1.280 0.80 none none Bug Screen Existing Rear(E) 54.0 1.280 0.80 none none Bug Screen Existing Rear(E) 160.0 0.400 0.35 none none Bug Screen Altered Rear(E) 3.5 1.280 0.80 none none Bug Screen Existing Right(S) 39.5 0.400 0.35 none none Bug Screen Altered Right(S) 28.1 1.280 0.80 none none Bug Screen Removed Right(S) 24.0 0.400 0.35 none none Bug Screen New Right(S) 52.0 1.280 0.80 none none Bug Screen Existing Front(IM 3.5 1.280 0.80 none none Bug Screen Existing Front(W) 82.7 0.400 0.35 none none Bug Screen New Front(IM 57.5 1.280 0.80 none none Bug Screen Removed HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80%AFUE Packaged Air Condition. 11.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status Existing HVAC Ducted Ducted Attic,Ceiling Ins, vented 4.2 Existing WATER HEATING CITY OF Qty. Type Gallons Min. Eff Distri-utionNi,r, QUIto Tus T1'D ivy rFi(jCT DATF EnergyPro 5.1 by Ener Soft User Number:6712 RunCode:2013-10-23T40• A33 RV fage 3 of 11 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R • Project Name Building Type ®Single Family ❑Addition Alone Date A Residence Remodel 1 ❑Multi Family m Existing+Addition/Alteration 11012312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach.The enforcement agency determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. CITY OF ZF _& DEPT, �A r�I% • o FOR CONS t� EnerqvPro 5.1 by EnerqySoft User Number:6712 Run Code:2013-10-23110:36:33 ID: Pa e 4 of 11 DATE�8Y PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R • Project Name Building Type m Single Family ❑Addition Alone Date A Residence Remodel ❑Multi Family m Existing+Addition/Alteration 10/23/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftZ- r Space Heating 13.32 9.18 4.14 Space Cooling 179.43 146.00 33.43 Fans 37.16 30.08 7.08 Domestic Hot Water 17.04 17.04 0.00 Pumps 0.00 0.00 0.00 Totals 246.96 202.31 44.65 Percent Better Than Standard: 18.1% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED .Fenestration Building Front Orientation: (tM 270 deg Ext.Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (tM 430 86 Fuel Available at Site: Natural Gas (N) 563 50 Raised Floor Area: 0 (E) 338 218 Slab on Grade Area: 2,055 (S) 540 116 Average Ceiling Height: 9.5 Roof 2,055 0 Fenestration Average U-Factor: 0.71 TOTAL: 470 Average SHGC: 0.51 Fenestration/CFA Ratio: 22.8% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple e. Documentation Author Company Scott Design and Title 24,Inc, 102312013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert,Ca 92211 Phone (760)200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing,verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) CITE/ Company Andrzej W.Weber,Architect =& s.4 UANTA Address 2278 Via Alba Name Andtzej Weber BUILD71 , City/State/Zip Palm Desert, CA 92260 Phone (760)340-3022 ¢ � Sig`eense# Date I Ener Pro 5.1 by Ener Soft User Number.,6712 RunCode:2013-10-23710:36:33 ID: I Page 5 of 11 1 -LL-- J BY i CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date A Residence Remodel ❑Multi Family m Existing+Addition/Alteration 11012312013 OPAQUE SURFACE DETAILS r Surface U- Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 1 4 Location/Comments Roof 2,021 0.049 R-19 0 20 ExisM 4.2.1-A4 Exisitng Residence Wall 490 0.102 R-13 0 90 Altered 4.3.1-A3 E=4.3.1-A2) Exisitng Residence Wall 86 0.102 R-13 90 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitng Residence Wall 35 0.102 R-13 106 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitng Residence Wall 425 0.102 R-13 180 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitnq Residence Wall 35 0.102 R-13 254 90 Altered 4.3.1-A3 E=4.3.1-A2 Exisitng Residence Wall 172 0.102 R-13 270 90 Altered 4.3.1-A3(E=4.3.1-A2) Exisitng Residence Door 48 1.450 None 270 90 Existing 4.5.1-A1 Exisitng Residence Slab 2,021 0.730 None 0 180 Existing 4.4.7-A1 Exisitng Residence+ Roof 34 0.031 R-30 0 0 New 4.2.1-A20 Addition Wall 23 0.102 R-13 0 90 New 4.3.1-A3 Addition Wall 90 0.102 R-13 270 90 New 4.3.1-A3 Addition Slab 34 0.730 None 0 180 New 4.4.7-A 1 Addition FENESTRATION SURFACE DETAILS ID Type Area U-Factor. SHGC Azm Status Glazing Type Location/Comments- 1 Window 50.3 1.280 Default 0.80 Default 0 Existing Single Non-Metal Clear Exisitng Residence 2 Window 54.0 1.280 Default 0.80 Default 90 Existing Single Non-Metal Clear Exisitng Residence 3 Window 80.0 0.400 NFRC 0.35 NFRC 90 Altered Double Non Metal Tinted Exisitng Residence 4 Existing 1.280 Default 0.80 Default Single Non-Metal Clear pre-altered for above 5 Window 80.0 0.400 NFRC 0.35 NFRC 90 Altered Double Non Metal Tinted Exisitng Residence 6 Existing 1.280 Default 0.80 Default Single Non-Metal Clear pre-altered for above r` 7 Window 3.5 1.280 Default 0.80 Default 106 Existing Single Non-Metal Clear Exisitng Residence 8 Window 2.0 . 0.400 NFRC 0.35 NFRC 180 Altered Double Non Metal Tinted Exisitng Residence 9 Existing 1.280 Default 0.80 Default I Single Non-Metal Clear pre-aitered for above ` 10 Window 2.0 1.280 Default 0.80 Default 180 Removed I Single Non-Metal Clear Exisitng Residence 11 Window 2.0 0.400 NFRC 0.35 NFRC 180 Altered Double Non Metal Tinted Exisitng Residence 12 Existing 1.280 Default 0.80 Default Single Non-Metal Clear pre-altered for above 13 Window 6.0 1.280 Default 0.80 Default 180 Removed Single Non-Metal Clear Exisitng Residence 14 Window 12.0 0.400 NFRC 0.35 NFRC 180 New Double Non Metal Tinted Exisitng Residence 15 Window 3.5 1.280 Default 0.80 Default 180 Existing Single Non-Metal Clear Exisitng Residence 16 . Window 45.0 1.280 Default 0.80 Default 186 Existing Single Non-Metal Clear Exisitng Residence (1) LI-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value , 2 SHGC Type: 116-13=Default Table from Standards,NFRC=Labeled Value 1 EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Ri ht Fin Len Ht tID Exterior Shade Type SHGC H t Wd 1 Bug Screen 0.76 2 Bug Screen 0.76 t 3 Bug Screen 0.76 '• 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Buq Screen 0.76 7 Bug Screen 0.76 ` 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 1. 1 ,�.1 r-_1 A I ITA I 13 Bug Screen 0.76 RI Of f 1 -_W o y _ 14 Bu Screen 0.76 ( nr `' 15 Bug Screen 0.76 16 Bug Screen 0.76 3 74 Energypro 5.1 by Ener Soft User Number-6712 RunCode:2013-10-23T10:36 0 - lD:__ RV Pa' e 6 of 11 , CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 r CF-1 R • Project Name Building Type m Single Family ❑Addition Alone Date A Residence Remodel ❑ Multi Family 0 Existing+Addition/Alteration 0/23/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 3.5 1.280 Default 0.80 Default 180 Existing Single Non-Metal Clear Exisitng Residence 18 Window 20.1 1.280 Default 0.80 Default 180 Removed Single Non-Metal Clear Exisitng Residence 19 Window 12.0 0.400 NFRC 0.35 NFRC 180 New � Double Non Metal Tinted Exisitng Residence 20 Window 35.5 0.400 NFRC 0.35 NFRC 180 Altered Double Non Metal Tinted Exisitng Residence 21 Existing 1.280 Default 0.80 Default I Single Non-Metal Clear pre-altered for above 22 Window 3.5 1.280 Default 0.80 Default1270 Existing Single Non-Metal Clear Exisitng Residence 23 Window 15.0 0.400 NFRC 0.35 NFRCNew Double Non Metal Tinted Exisitng Residence 24 Window 30.0 1.286 Default 0.80 DefaultRemoved Single Non-Metal Clear Exisitng Residence 25 Window 40.2 0.400 NFRC 0.35 NFRCNew Double Non Metal Tinted Exisitng Residence 26 Window 27.5 1.280 Default 0.80 DefaultRemoved Single Non-Metal Clear Exisitng Residence 27 Window 27.5 0.400 NFRC 0.35 NFRC 270 New Double Non Metal Tinted Addition (1) Q-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Ri ht Fin ID Exterior Shade Type SHGC H t Wd Len Hot LExt REA Dist Len Hat Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 i "�/ 1 ir- oLl _�It\iJ F \ •tet;--�--. , - ,`� fes► ,,.�, OR • o . Ener Pro 5.1 b Ener Soft User Number:6712 RunCode:2013-10-23T1 b:361 -'-'ID. C Pe e 7 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF-1 R • Project Name Building Type ® Single Family ❑Addition Alone Date A Residence Remodel ❑ Multi Family ® Existing+Addition/Alteration 10/23/201 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existin Altered Removed Volume Year Built Existing HVAC Exisitng Residence 2,021 19,200 1985 Addition 34 306 Totals 1 341 Z0211 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type__ Min. Eff. Coolin Type Min. Eff. Thermostat Type Status Existing HVAC 1 Central Furnace 80%AFUE Packaged Air Condition 11.0 SEER Setback Existing HVAC DISTRIBUTION Duct Ducts System Name Heating Cooling Duct Location R-Value Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins,vented 4.2 ❑ Existing WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul.R- S stem Name Qty. Type Distribution (Btu h) al or RE Pilot Value Status Existing State DWH 1 Small Gas No Pipe Insulation 40,0001 40 0.56 n/a n/a Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length fto .6 � ip. Insul. Control aty. HP Plenum Outside Buried a $.ste aWa 'e ,Le• th t piaMr Thick. ❑ r rr� t pUI IN t ❑ I /1 A ❑ r r Ener Pro 5.1 by EnergySoft User Number:6712 RunCode:2013-10-23T10 ID: Pa•e 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date A Residence Remodel 11012312013 NOTE:Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD,or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(*)below.This Mandatory Measures Summary shall be incorporated into the permit documents,and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: §116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products(except field-fabricated windows)have a label listing the certified LI-Factor,certified Solar Heat Gain Coefficient SHGC ,and infiltration that meets the requirements of 10-111(a). 117:Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulatinq Material. Indicate type and include on CF-6R Form. §118(1):The thermal emittance and solar"reflectance values of the cool roofing material meets the requirements of§118(1)when the installation of a Cool Roof is specified on the CF-1 R Form. .*§l 50 a :Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 150(b):Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. 150(c):Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50 d :Minimum R-1 3 insulation in raised wood frame floor orequivalent LI-factor. 150(f):Air retarding wrap is tested labeled,and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150(e)IA:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. -x• §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. f !,Space Conditioning,Water Heating and Plumbing System Measures: ` §110-§113:HVAC equipment,water heaters,showerheads,faucets and all other regulated appliances are certified by the Energy . Commission. §113(c)5:'Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve,backflow prevention,pump isolation valve,and recirculation loop connection requirements of§113(c)5. §115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances '(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and spa heaters. 150(h):Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACOA. 150(i):Heating systems are equipped with thermostats that meet the setback requirements of Section 112 c . §150(j)1 A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. ' §1500)1 B:Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1506)2:First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of recirculating sections of hot water�i es are insulated per Standards Table 150-13. §150(j)2:Cooling system piping(suction,chilled water,or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2:Pipe insulation for steam hydronic heating systems or hot water systems>15 psi met e�tre'[n nt of tN4Tj e 123A 150 '3A:Insulation is protected from damage,includingthat due to sunlight moisture e ui aiR e41a d i DEPT. §1500)3A: Insulation for chilled water piping and refrigerant suction lines'includes a vapor etardan%' dh_Zl,s e 'r ED -conditioned space. "§150(j)4:Solar water-heating systems and/or collectors are certified b the Solar Ratin aid Certification Corporation. DATES BY • EnergyPro 5.1 by EnergySoR User Number:6712 RunCode:2013-10-23T10:36:33 ID: Page 9 of 11 } MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date A Residence Remodel 11012312013 §150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181,UL 181A,or UL 181 B or aerosol sealant that meets the requirements of UL 723.If mastic or tape is used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used §150(m)1:Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air.Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated dampers. §150(m)9: Insulation shall be protected from damage,including that due to sunlight,moisture,equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10:Flexible ducts cannot have porous inner cores. §150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation .required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot li ht. §114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction and return lines,or built-up connections for future solar heating. §114(b)2:Outdoor ools ors as that have a heat pump or as heater shall have a cover. §114(b)3:Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 :Residential pool systems orequipment meet the pump sizing,flow rate,piping,filters,and valve requirements of§150 Residential Lighting Measures: §150(k)1:High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacyluminaire asspecified b 150 k 2. §150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d). -§150(k)4:Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5:Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a medium screw-base socket. 150(k)6:Lighting integral to exhaust fans,in rooms other than kitchens,shall meet the applicable re uirements of§150(k). 150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION:Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,dimmer,energy management system (EMCS),or a multi-scene programmable control system;and all permanently installed Auminaries in garages,laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9:Permanently installed lighting that is internal to cabinets shall use no more than 20 yva�s�of po errpe im ar o0 0 illuminated cabinet. I r T r ninj BUILDING & SAFETY DEPT. /APPROVED FOR CONSTRUCTION SEnergyPro 5.1 by EnergySoff User Number.6712 RunCode:2013-10-23710:36:33 ID: Page 10 of 11 BY - MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R 41 Project Name Date A Residence Remodel 11012312013 §150(k)10:Permanently installed luminaires in bathrooms,attached and detached garages,laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2:Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11:Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages, laundry rooms, closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)12:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13:Luminaires providing outdoor lighting,including lighting for private patios in low-rise residential buildings with four or more :dwelling units,entrances,balconies,and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy.EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch,a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system(EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptions to§150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3:Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket,and consume no more than five watts of power as determined according to§130,d). §150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130,131, 134,and 146. §150(k)16:Permanently installed lighting in the enclosed,non-dwelling spaces of low-rise residential buildings with four or more _dwelling units shall be high efficacy luminaires. EXCEPTION:Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft User Number:6712 RunCode:2013-10-23710:36:33 ID: Page 11 of 11