Loading...
06-0676 (RPL) I�IIIII VIII III VIII IIII 13 IET4'v1 4 �j P.O. BOX 1504 - - J ^� VOICE(760) 777-7012 78-495 CALLE TAMPICO FAX(760) 777-7011 LA QUINTA,-CALIFORNIA 92253 BUILDING&SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/15/06 Application Number: 06-00000676 Owner: Property Address: 80771 CALLE AZUL PUERTA AZUL PARTNERS APN: 762-240-003-37 -300962- 17700 SW UPPER BOONES FERRY RD Application description: POOL - RESIDENTIAL SUITE 100 Property Zoning: MEDIUM DENSITY RES -tr: F �y PORTLAND, OR 97224 Application valuation: 50000 Contractor: Applicant: Architect or En116" 2,006 RIPARIAN ENVIRONMENTS P.O. BOX 13990 CITY OF LAQUINTA PALM DESERT, CA 92255 FINANCEQEPT. (760)398-9997 . < Lic. No. : 839002 ---- ---- ------ ------- --- --------------- - - ------- ------------- - --- -- ---- - -------- - --- --- ----- ----- LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000)of Division 3 of the Business and Professionals Code,and my License is in full force and effect. _ I have and will maintain a certificate of consent to self-insure for workers'compensation,as provided License Class: C8 C27 C29 License No.: 839002 for by Section 3700 of the Labor Code,for the performance of the work for which this permit is { �,t issued. �aie:f.�2�TG� �prl�ractor: - y I,y � '�( I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. My workers'compensation OWNER-BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 17697S4-2005 following reason(Sec.7031.5,Business and Professions Code: Any city or county that requires a permit to _ I certify that,in the performance of the work for which this permit is issued,I shall not employ any construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for the person in any manner so as to become subject to the workers'compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that,if I should become subject to the workers'compensation provisions of Section License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or 3700 of the Labor Code, shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500).: D le S 6 Applicant (_1 I,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL,AND SHALL Contractors'State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees,provided that the DOLLARS($100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If,however,the building or improvement is sold within SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES. ' one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT 1—I I,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044,Business and Professions Code: The Contractors'State License Law does not apply to an owner of• conditions and restrictions set forth on this application. property who'builds or improves thereon,and who contracts for the projects with a contractor(s)licensed 1. Each person upon whose behalf this application is made,each person at whose request and for pursuant to the Contractors'State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_1 I am exempt under Sec. ,B.&P.C.for this reason the owner,and the applicant,each agrees to,and shall defend,indemnify and hold harmless the City of La Quinta,its officers,agents and employees for any act or omission related to the work being Q /� performed under or following issuance of this permit. ,, ) V Date: © Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued(Sec.3097,Civ.C.). - city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this county to enter upon the above-mentioned droperty for inspection purposes. Lender's Name: // �v Dat,e:D't ( w Signature(Applicant or Agent): Lender's Address: LQPERMIT Application Number• . . . . . 06-00000676 Permit . . . BLDG POOL PERMIT Additional desc . Permit Fee . . . . 414.50 Plan Check Fee 269.43 Issue Date . . . . Valuation . . . . 49027 Expiration Date 8/14/06 Qty Unit Charge Per Extension BASE FEE 252.00 25.00 6.5000 THOU BLDG 25, 001-50,000 162.50 ---------------------------------------------------------------------------- Permit . . . MECH POOL Additional desc . . Permit Fee . . . . 26.00 Plan Check Fee 6.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/14/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 --------------------------------------------------7------------------------- Permit . . . ELEC POOL PERMIT-RES Additional desc . Permit Fee . . . 45.00 Plan Check Fee 11.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/14/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 30.0000 EA ELEC PRIVATE SWIMMING POOL 30.00 ---------------------------------------------------------------------------- Permit. . . . PLUMBING Additional desc . Permit Fee 33.00 Plan Check Fee 8.25 Issue Date . . . Valuation . . 0 Expiration Date 8/14/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12 .00 1.00 3 .0000 EA PLB WATER INST/ALT/REP' 3 .00 1.00 3 .0000 EA PLB GAS PIPE 1-4 OUTLETS 3 .00 ---------------------------------------------------------------------------- Permit . . . . . . WALL/FENCE PERMIT LQPERMIT Application Number . . . . . 06-00000676 Permit . . . WALL/FENCE PERMIT Additional desc . Permit Fee . . . . 25.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 973 Expiration Date 8/14/06 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 2.0000 HIND BLDG 501-2,000 10.00 ------------------------------------------------------ --------------------- Special Notes and Comments POOL & SPA. 8 L.F. 5' EQUIPMENT BLOCK WALL & 50-L.F. 4 ' BLOCK WALL, ORCO SYSTEM. ALARMS./BARRIERS SHALL BE IN PLACE PRIOR TO PRE-PLASTER INSPECTION. Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 543 .50 .00 .00 543 .50 Plan Check Total 295.43 .00 .00 295.43 Grand Total 838.93 .00 .00 838.93 LQPERMIT Bin #, �$ z- City of La Quinta Building& Safety Division Permit P.O. Box-1504, 78-495 Calle Tampico La Quinta, CA 92253 -.(760) 777-7012 o -77 Bul ding Permit Application and'Tracking Sheet Project Address:" 163Co . Z-1 "C j y�. l Owner's Name: 01— A.P.Number: Address: p Z Legal Description: • fTe ST,Zip: , . Contractor: qq C A �Z4 1y1V rfd^. d phone: Address: I Project Description:' City,ST,Zip: P P✓ e ' Telephones oa " : '� �� _ _ " " State Lit.# - City Arch.,Engr.,Designer: - - Address: f GAJ . o;l i C C e;I"a City,ST,Zip: Telephone: Construction Type: Occupancy: State Lie.#: Project type(circle o11 n11 e): New Add'n Alter Repair Demo Name of Contact Person: .L LSSJ�J Sq.Ft.: #Stories: #Units: Telephone#of Contact Person:p - 5 �-� „Estimated Value of Project: 1 �b OCO APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKINGPERMIT FEES Plan Sets Plan Check submitted s Item Amount Structural Calcs, Reviewed,ready for corrections Truss Cates. Plan Check Deposit Called Contact Person . . Plan Check Balance Energy Calcs. Plans.Picked up Construction Flood plain plan Flans resubmitted Mechanical Grading,plan 2”Review,ready for"corrections/issue Electrica Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up • �---- . i S.M.I: H.O.A.Approval Plansr i�ed�� ILA t /� OUR �. Grading IN HOUSE: i. c A 1=1=I E = eview,r, ylfor'correctionVasue Cal �r 1 �-� R Planning Approval Developer Impact Fee led Contac'tt�Pe�rs pKU-V t- t ISR �< <r•+-�'�, v' A.LP.P. Pub.Wks.Appr Date of permipi§�deGUNO C"`,—' School Fees T BY_- --- Total Permit Fees � ?3 y q oA �,, IIIIIIIIIIIIIIIIIIIIIIIII 14 IE " GAS-FIRED RTH TECHIVOL CP UHearth & Home Technologies Inc. C � L �� 1915 W. Saunders St. Mt. Pleasant, Iowa 52641 Division, HON INDUSTRIES LISTEDwww.fireplaces.com IN8TALLATION & OPERATING INSTRUCTIONS PATIO'CAMP 11RE: :F!resFultcmusing property. . damage,personal ss of life. ,k Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other fireplace. What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier,call the fire department. IMPORTANTI Read all instructions carefully before — Installation and service must be performed by a starting installation. Failure to follow these installa- qualified installer,service agency orthe gas supplier. tion instructions may result in a possible fire hazard and will void the warranty. This manual must be used for installation and retained by the homeowner for operation and maintenance. Save this manual for future referencel If you have questions or concerns, please contact the Technical Services Dept., Hearth & Home Technologies Inc., 1-800-827.6841 or 1-888-427-3973. This product is covered by one or more of the followingates) ~ 4852,548;4,875,464, 5,000,162; 5,016,609; 5,076,254; 5,1911877; 5,218,953; 328,356; 5,429,495;5,452,708; 5,542,407; 5,613,487; (Aus93,322, tralia) y43790; 586383; (Canada) 1,123,296; 1,297,746;2,195,264; (Mexico)97-0457;(New Zealand)200265;or other U.S.and foreign patents pending. 01104 4004-001 B . 1 PATIO CAMPFIRE INSTALLATION INSTRUCTIONS RTH rEc►iivocooiEs h B. SAFETY INFORMATION The Patio Campfire has been tested in accordance with IAS US Clothing or other flammable materials should not be placed requirements_for Outdoor Gas.Fireplaces,Draft 4-96 and ANSI. on or near the appliance. 221.58-1995/CGA 1.6-M96 for Canada and has-been listed by Underwriters Laboratory (UL)-for installation and operation as Any guard or other protective device removed for servicing i described in these installation and o eratin the appliance must be replaced prior to operating the p g instructions. appliance. The installation must conform with local codes or,in the absence of local codes,with the National Fuel Gas Code ANSI 2223.1 or Installation and repair should be done by a qualified service CAN/CGA-B149.1,National Gas Installation Code or CAN/CGA- Person. The appliance should be inspected before use and B149.2,Propane Installation Code. at-least annually by a qualified service person.More frequent cleaning may be required as necessary. It is imperative that IMPORTANT: Installation of natural gas should be done by a the control compartment, burners and circulating air qualified installer, service agency or gas supplier. passageways of the appliance be kept clean. The appliance and its manual shutoff valve must be disconnected Inspect the fuel supply connection (including the hose for from the gas supply piping system during any pressure testing LP models).before each use of the appliance. of the system at test pressures in excess of 1/2 psig (3.5kPa). • If it is evident there is excessive abrasion or wear, or the This appliance must be isolated from the gas supply piping hose is cut, it must be replaced prior to the appliance being system by closing its manual shutoff valve during any pressure put into operation. testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa). The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure regulators Note:All new LP cylinders(and in many cases used cylinders) and hose assemblies must be those specified in thismanual may contain water, air or other contaminants. It is essential that these substances be released before filling the cylinder The LP gas supply cylinder used with LP models must be and placing into service-Water vapor present in the gas vapor constructed and marked in accordance with the may cause the regulator to "freeze up" and cause an specifications for LP gas cylinders of the U.S. Department of interruption to the gas flow. This interruption will cause the Transportation (DOT). appliance to shut down. To prevent this from occurring, it is Cylinders must be stored outdoors in a well ventilated area essential that a qualified individual always purge a new tank out of the reach of children. Disconnected cylinders must thoroughly before placing it into service. It is recommended have threaded valve plugs tightly installed and must not be that cylinders that have not been used for extended periods of stored in a building, garage or any other enclosed area. time also be purged before use. Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply(natural gas line or LP gas cylinder). • The LP gas cylinder supply system must be arranged for • Children and adults should be alerted to the hazards of high vapor withdrawal. . surface temperatures and should stay away to avoid burns The LP gas cylinder used must include a collar to protect the or clothing ignition. cylindervalve. • Young children should be carefully supervised when they When an LP model is not in use, the LP gas must be turned are in the area of the appliance. off at the supply cylinder. • Never leave the appliance unattended during operation. Note: Do not use this appliance if any part has been under water. Immediately call a-qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 01/04 4004-001B 3 SHOWER ON/OFF CONTROL (PLASTIC OR AVAILABLE) A . . . . . . . . . . . . . . . . . . . . . . . . RETAINING WALL I 18'HIGH FIRE PIT I GAS UNE 1" r -'-------------""""""'-- — t—_________ _ ___ _— —— ___ ——— _ POOL EQUIP.SCREEN (see manufs /or details CONCRETE BLOCK P� ) _ + •. �1 WALL S HIGH' +12" O� I STUCCO FINISH + f TO MATCH HOUSE I ; I ;I II SII �I I I � S•10" ;jl I SUBMERGIBLE �j� PUMP �I I POOL 1•2 111 , (electric line) I N 1 ° IRE �I FP T .I V-6„ 71 _ HI ��I _ O O O GUNI I I - GUNTEE C WALLS I CA III (SEE STRUCTUAL PLAN ;I FOR DETAILS) I 71 �: 1 ... :I 1n SPA C) '•�� 'l :I . 11 .I .. e 11 i t 3 -0'' . i i 1"Gas Line - •• •• ( r ' 1 If 11 &Electric line I I I 11 11 1 for Future BBQ 111 EXISTING &CONCRETE BLOCK WALL E :r •...••...• I \ - t T.Limit - • ,``\ �� •�\ 1 If If 1 /11 111 / _____---- I CITY OF LA QUANTA BUILDING & SAFETY DEPT, APPROVED FOR CONSTRUCTION DATE-2-/6 --06 BY—.S T 7/ Po BOX 13990 TOM OLMSTEAD POOL & SPA syp�af� �. a?adTscape Palm Desert, CA 92255 81 CALLE AZUL - LOT 37 ° Office (760) 398-9997 DATE: 01-11-06 FAX 760 398-3290 LA QUINTA CA 92253 ��� = ( > ' SCALE: 1/8"=1 e#no u 1 pw at 0#k& q nto sj CA LICENSE 839002 t: LID COVER FOR SUM.PUMP B FIRE PIT (see manuf spec. for details) 0 A O -30" O +0' +1' -7.:5" 14.5" 21775' -29' -6" +1" DRAIN PIPE WROUGHT IRON Q SECTION HAND RAIL N e LINE ZWATE.1 _ +0" +1 I — CONCRETE DECKING IIII�� 1111-1111-1111=1111 II =111 1111 MIfill11 fillIII .:•',:.:• '. = I Al -11 • •. _ - - •. . . '. '.IIII��IIIII DRAIN LINE TO MAIN DRAIN LINE :IIII=IIII D-tlni,I III-1II-IIII ELECTRIC LINE FOR SUBMERGIBLE PUMP CONNECTED TO GFI z 1'GAS LINE SUBMERGIBLE GUNITE FOR FIRE PIT PUMP IN 2"SLEEVE © SECTION CONCRETE CAP BENCH o CONCRETE CAP 0 WATER LIN io CONCRETE GUNITE FLOOR ' PO BOX 13990 TOM OLMSTEAD FIRE PIT DETAIL IanTdses�pe ' Palm Desert, CA 92255 80-721 CALLE AZUL - LOT 37 ° o , '""• Office (760) 398-9997 LA QUINTA CA 92253 DATE: 01-26-06 ( � FAX (760) 398 -3290 ' SCALE: 1/4"=1 e off. v,i;: n e a '01 ez.n `t, s CA LICENSE 839002 EXISTING WALL (:A ) 2'-0• I� ,,-0• in TILE FINISH N NEW RETAINING WALL o r POOL WATER LINE CONCRETE BLOCK (SET BEFORE GUNITE) III=fill=1111=fill.11 — Jill_— — � IIII—Jill-1111-fill- 111=1111-1111- II-1111=1111-11 =1111=1111-11 fill Jill 11 Mi w -11 II-fill-11 —IIII II 1111 1111 IIII �I' PEBBLE FINISH PLASTER rt. =1111=_1111=1111-11'• .'• =1111,-11 JIII. =1111=1111=1111= IIT'rhl—Iln =II 11Ri =11' r WATER FEATURE WATER LINE =_fill=fill=fill=1111-1111=Jill-III =1111 11 _ =1111=1111 1111=1111-1111=1111=111=_111= =11.'. .. •'. . -IIII—1111=IIII—II I IIII—IIII—111 =IIII II 1111 POOL GUNITE (SEE STRUC.PLAN V-6- b FOR DETAILS) rel' TOM OLMSTEAD WATER FEATURE SECTIONPO BOX 13990 - a�oas,e,apa�e Palm Desert, CA 92255 80-721 CALLE AZUL - LOT 37 ° Office (760) 398-9997 LA QUINTA, CA 92253 DATE: 01-11-06 ( ', ( �� FAX (760) 398 - 3290 SCALE: 1/8"=1 e n u ( r tt of in e ;nj 1,; s CA LICENSE 839002 s