04-4051 (CONR)IIIIIII VIII III VIII IIII 31 ce BUILDING & SAFETY DEPARTMENT .0. 1504 (760),777-7012 F 9 212ODS-4 ALLE TAMPICO FAX (760) 777-7011 LA I A, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 crnr OF LA QUINTA FINANLiCUCr l I BUILDING PERMIT Application Number iO47-0.000,4051"7 Date 3/14/05 Property Address . . . . . . .80391 AVENUE 52 APN: 772-410-038- Application description . . . NEW COMML -OTHER NON-RESIDENTIAL Property Zoning . . . . . . LOW DENSITY RESIDENTIAL . Application valuation 7212 Owner Contractor ND LA QUINTA PARTNERS OWNER 375 N FRONT ST STE 200 COLUMBUS OH 43215 ------ Structure Information GATE HOUSE ----- Construction Type TYPE V - NON RATED ' Occupancy Type . . . . BUSINESS <50 Flood Zone . . . NON -AO FLOOD ZONE Other struct.info CODE EDITION 2001 FIRE SPRINKLERS YES - OCCUPANT LOAD 2.00 1ST FLOOR SQUARE FOOTAGE' 120.00 t' ----------------------------------------------------------------------------- Permit . . . . BUILDING PERMIT Additional desc Permit Fee 99.00 Plan Check Fee 64.35 Issue Date Valuation . . 7212 Qty. Unit Charge Per Extension BASE FEE 45.00 6.00 9.0000 THOU BLDG 2,001-25,000 54.00 ---------------------------=------7------------------------------7----------- Permit ELEC-NEW COMMERCIAL .Additional desc Permit Fee 17.40 Plan Check Fee 4.35 Issue Date Valuation . . . . 0 Qty Unit Charge Per. Extension BASE FEE 15.00 120.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 2.40 --------.----------------------------------------------------- 7 -------------- Permit . . . GRADING PERMIT Additional desc 'Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per I Extension BASE FEE `- ';'°" 15.00 ---------------------------------------------------------------------------- P.O. BOX 1504a �� VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: (�4 A051 Applicant: Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS - LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class License No. Date Contractor - r: - OWNER -BUILDER DECLARATION ` hereby. iffirn under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to ccnstruct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business -and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): _ r I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees,•provided that the improvements arenot intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: ,The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. BA P.C. for this reason s Date 3 ' �/'OS Owner PMA N - WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3.700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued; I shall not employ any person In any manner .so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ' Date Applicant rd -6V WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF,THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. , . . CONSTRUCTION LENDING AGENCY I hereby affiim_under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work Is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and slate laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date J Signature (Applicant or Agent)- e0 +df✓7�� n1l. J� .0h Page 2 Application Number 04-00004051 Date 3/14/05 Permit . . . . . MECHANICAL, Additional desc Permit Fee 39.50 Plain Check Fee 8.25 Issue Date . . . . Valuati'on'r Qty Unit Charge Per Extension BASE FEE .15-.0'0 1.00 9.0000 EA MECH,FURNACE <=100K 9.00 1.00 9. 0000 ,Ekk MECH.B/C <=3HP/100K BTU ''9,."00.° inr i!fl. 3 1.00 6.5000 EA' MECH VENT FAN 0 --------------- ------------ I ------------------------------- Permit .,PLUMBING k," inn, w, Additional deso Fee: Permit4.00 P 1 a!h Check Fee ,,, 11.25 Issue .' Date .r ValiTation . . . . 0 Qty Unitt-Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA.... PLB FIXTURE 12.0.0 1.00 15.0000 EA.- PLB BUILDING;,.ISEWER 15.00 1.00 3.0000 EA. PLB WATER INST/ALT/REP-1­ 3.00 ----- ---------------------------- ------------ ­,-Specia,.-1 Notes and ..-Comments ENTRY.GATEHOUSE (HIDEAWAY GOLF Cft1B)120 ,SQ, -FT. -p"B" OCC.-,. TYPE V -N. 2001 CODES Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 6.44 ENERGY REVIEW FEE 6.44 STRONG MOTION (SMI) COM_ 1.5i Fee summary Charged Paid- Credited, ----------------- Due ----------- ---------- ---------- Permit Fee Total 215.90 .00 00,:,,-- ---------- 2-:115.-,9,0 Plan Check Total 88.20 .00 00 88.20. Other Fee Total 14.39 .00 .00 q Grand Total 318.49 ._00 -.00. �A t -1 TITLE 24 REPO Title 24 Report for: Hideaway Gate House 52nd Street Indio, CA 92201 Project Designer: Nick Fullerton Architect P.C. 8000 Hwy 35 Suite #3 Bigfork , MT 59911 406-837-2295 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 CITY OF LA QUINTA BUILDING & SAFETY DEPT. Job Number: APPROVED FOR C T UCSTION DAT /w B . Date: �;Z 8/16/2004 The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. I ' EnemvPro 3.1 By EnerovSoft Job Number. User Number. 5862 1 11�r�/c II� II VIII III VIII IIII 32 . IE CITY OF LA QUINTA BUILDING & SAFETY DEPT. Job Number: APPROVED FOR C T UCSTION DAT /w B . Date: �;Z 8/16/2004 The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. I ' EnemvPro 3.1 By EnerovSoft Job Number. User Number. 5862 1 11�r�/c C • PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE Hideaway Gate House DATE OF PLANSBUILDING 8/16/2004 PROJECT ADDRESS CONDITIONED FLOOR AREA 120 Sq.Ft ` 52nd Street Indio BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL 0 PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # Nick Fullerton Architect P.C. 406-837-2295 contractor preparing documents for work that I have contracted to perform. DOCUMENTATION AUTHOR TELEPHONE Checked by/Date G.R. Rose CAD Design (760) 345-4859 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR DATE OF PLANSBUILDING DATE Gina Rose CONDITIONED FLOOR AREA 120 Sq.Ft ` CLIMATE ZONE 1 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL 0 HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, NEW CONSTRUCTION ADDITION [:] ALTERATION F-1 EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR SIGNATURE DATE Gina Rose ` The Principal Designers hereby certify that the proposed bukKg design represen ed in the construction documents and model) d for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ F� F-] 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. F] ❑ E] 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENVA Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE Nick Fullerton Architect P.C. LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIG RE LIC. NO. DATE , GR Rose CAD Design - 6S� iozz IEnemvPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:3 of 19 1 r - PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 DATE Hideawa Gate House 8/16/2004 :::] ANNUAL SOURCE ENERGY USE SUMMARY kBtuls ft- r Standard Proposed Compliance ENERGY COMPONENT Design Design Margin swward a+oearea _ W,. Space Heating. 16.67 0.00 16.67 Space Cooling 127.50 102.50 25.00 Indoor Fans 110.00 145.00 -35.00 .m.F Heat Rejection 0.00 Pumps & Misc. 0.00 Dgmestic Hot Water 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Lighting 17.50 17.50 0.00 Receptacle 17.50 Process 0.00 TOTALS: 289.17 17.50 0.00 282.50 0.00 r r _ 0.00 $ 20 30 80 10 L50 70 ,50E0: 9p 100 110 120 130 140 6.67s9s Y� Percent better than Standard: 2.3% ( 2.3% excluding process)( 2.5% excluding process & receptacle) BUILDING COMPLIES GENERAL INFORMATION Building Orientation East 90 deg Conditioned Floor Area 120 sgfc 1 Number of Stories Unconditioned Floor Area' 0 sgft 1 Number of Systems Conditioned Footprint Area 120 sgfL 1 Number of Zones Orientation Gross Area Glazing Area Glazing Ratlo 119 29 24.4% Front Elevation East sgft sgft. 60 o 0.0% Left Elevation (South) sgft sgft 119 0 0.0% Rear Elevation est sgfL sgfL 60 20 33.3% Right Elevation Total Roof (North) sgfL sgft sgfL sgfL SOL sgfL 1 358 49 I 120 E::::::� Standard Proposed Lighting Power Density 0.600 wrsgft 0.600 wisgfL Prescriptive Env. Heat Loss 57 60 Prescriptive Env. Heat Gain 5,805 6,348 Remarks: Standard Building (Compliance) Run Initiation Time,• 08 610 0:14:22 Run Code: 1092676462 EnergyPro 3.1 By EnergySoft User Number. 6862 Job Number. Page:4 of 19 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PER PROJECT NAME Hideaway Gate House DATE 8/16/2004 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area sgft. Inst LPD Is 1 Port LPD Is 1 Ctrl. Tailored proc. _ Credits '= LPD . > Loads is ? (YYlsf) 3 . Wst) ^. Trane Mini -Split System Gate House Comp Bldg Other 120 '0.600 h *' S L "Z' 4 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special. . documentation; - EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the spell. Justification and documentation submitted. n rapid The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant Authnrisad Sinnature or S}amn Run Initiation Time: 08/16/0410:14:22 Run Co 09 676462 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:5 of 19 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 Site Assembled Glazing Check box if Building is — 100,000 sqft of CFA and — 10,000 sgft vertical glazing then NFRC Certification Is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. # PROJECT NAME Hideaway Gate House SHGC Glazing Type DATE 8/16/2004 1 OPAQUE SURFACES 20 0.720 0 0.60 Double Metal Tinted Default 3ate House Surface Framing # Type Type Act. Area U -Fac. Azm. Solar Gains Tilt YIN Form 3 Reference Location I Comments 3ate House 1 Roof Wood 120 0.028 0 0 X11 I R-38 Roof R.38.2x14.16 Gate House Double Metal Tinted Default 2 Wall Wood 40 0.059 0 90 X11 I R-21 Wall .21.2x6.16 Gate House 3 Wall Wood 90 0.059 90 90 X11 I R-21 Wall .21.2x6.16 Gate House 4 Wall Wood 60 0.059 180 90 X I I R-21 Well .21.2x6.16 Gate House 5 Wall Wood 119 0.059 270 90 x I I R-21 Wall (W.21.2x6.16) Gate House EXTERIOR SHADING # Exterior Shade Type Window SHGC H t. Wd. Overhang Left Fin Len, Hgt, I-Ext,RExt, Dist, Len. Hgt. Right Fin Len. Hgt. 1 None 0.76 4.0 5.0 2.0 0.1 2.0 2.0 0.1 --Dist. 2.0 0 0.1 2.0 0 2 None 0.76 FENESTRATION SURFACES Site Assembled Glazing Check box if Building is — 100,000 sqft of CFA and — 10,000 sgft vertical glazing then NFRC Certification Is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location I Comments 1 Window 20 0.720 0 0.60 Double Metal Tinted Default 3ate House 2 Window 21 0.850 90 0.59 Double Metal Tinted Default 3ate House 3 Window 8 0.720 90 0.60 Double Metal Tinted Default 3ate House EXTERIOR SHADING # Exterior Shade Type Window SHGC H t. Wd. Overhang Left Fin Len, Hgt, I-Ext,RExt, Dist, Len. Hgt. Right Fin Len. Hgt. 1 None 0.76 4.0 5.0 2.0 0.1 2.0 2.0 0.1 --Dist. 2.0 0 0.1 2.0 0 2 None 0.76 3 None 0.76 4.0 2.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.1 2.0 0 Run Initiation Time: 08116104 10814:22 Run Code* 1092676462 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:6 of 19 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 NAME Hideaway Gate House (DATE 8/16/2004 I eMoc RAI I Acre Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION CONTROL IDENTIFICATION V�latts er Lamp DESCRIPTION # Lam p + Ballast Total Waw # Watts 1 4 It Fluorescent T8 Ma EE F3 T8 1 32 Magnetic Ener 'Efficient 1. 1 39.0 39 Recessed Can Mounted-Flourescent 40W.• 40 No Ballast 5 40.0 200 S CONTROLLEDNOTETO: TYPE # OF LUMINAIRES AFIELD NOTES TO FIELD - For Building D® artment Use Only Lighting Schedule on Plans Shows Exterior Lighting Meets ❑ Efficacy and Control Requirement of 6130(c) ❑ Control Requirements ofa131(f) Subtotal from this Page 239 Total Portable Lighting (From LTG -1) �0 Less Control Credit Watts (From LTG -3) Adjusted Actual Watts MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED ,,NOTE, -XO, FIELDe' CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) S CONTROLLEDNOTETO: TYPE # OF LUMINAIRES AFIELD NOTES TO FIELD - For Building D® artment Use Only LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG - PROJECT NAME DATE Hideaway Gate House I 8/16/2004 ROOM # DEFAULT AREA OR ZONE ID 1s SF TOTAL WATTS B X C RE >260 SQUARE TOTAL AREA (SF) Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. 0 FEET a a a o a a o TOTALI WILDING - P LUMIN. TASK # OF TOTAL TOTAL TOTAL 0 0 ITABLE- PORTABLE ORT E LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE EET RE >260 SQUARE TOTAL AREA (SF) Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. 0 FEET a a a o a a o TOTALI WILDING - P LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Descrintlon FIXT. FIXTURE (SF) AREAS (D x E) (C x E) TOTAL TABLE 1C - PLANS SHOW ORT E LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE EET ROOM # OR ZONE ID TOTAL AREA (SF) Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. 0 TOTALI WILDING - P BL TOTAL AREA (SF) BUILDING SUMMARY (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Pagel of 19 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Hideaway Gate House 8/16/2004 ANNY—STEM FEATURES SYSTEM NAME • TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3 COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS Trane Mini -Split System Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 110 cfm None n/a Room PTAC 9.7 EER Trane Mini -Split System Yes Yes Ductless / No Fan n/a Ductless n/a No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? I VENTILATION I OUTDOOR DAMPERI ECONOMIZER I O.A. CFM PIPE INSULATION REQUIRED? C: Outside Air Cert G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be PIPEIDUCT INSULATION PROTECTED? D: Demand Control EC: Economizer less than Col. H on „-., -- ... ,,,,.,-,. I N• Natural Control See Section MECH-3. - I EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:9 of 19 1 F -j MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME HideawayGate House DATE 8/16/2004 CHILLER PUMPS Tot Motor Drive Pump Equipment Name Equipment Type Qty. Efficiency Tons Qty GPM BHP Eff. Eff. Control RETUS N FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Trane Mini -Split System Constant Volume Draw -Through 525 0.25 77.00/a 100.0% none 1QHW I BOILER SUMMARY Energy Factor or Recovery Efficiency Standby Loss or Pilot TANKINSUL. System Name System Type Distribution Type Qtyl Rated Input (Gals.) Vol. Ext R -Val. CENTRAL SYSTEM RATING HEATING COOLING System Name System Type Oft. Output Aux. kW Eff. O ut Sensible Efficiency Economizer Type Trane Mini -Split System Room PTAC 1 0 0.0 n/a 2,100 1,344 9.7 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETUS N FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Trane Mini -Split System Constant Volume Draw -Through 525 0.25 77.00/a 100.0% none Run InWation Tome* 08116104 1014@22 Run Codew 1092676462 EnergyPro 3.1 By Energysoft User Number. 5862 Job Number. Page:10 of 19 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME... . .. I DATE _ , . _ ,.. _ _ . I CFM CFM I BHP I MEff. I Eff. I Drive Tvoe I Output EXHAUIMWN EXHAUST FAN Room Name Qty. CFM BHP Motor Eff. Drive Eff. Room Name City. CFM BHP Motor Eff. Drive Eff. Gate House 1 110 0.15 77.00/ 97.0% I EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Paw: 11 of 19 1 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Hideawav Gate House I 8/16/2004 AW-F-CHANICAL VENTILATION a a a a® o a o a o 0 AREA BASIS AREA1 CFM I CFM (SF) I PER SF I (B x C) 0. OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (E F) REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO NS FER AIR 18 110 18 110 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). I EnerovPro 3.1 By EnemvSoft User Number. 5882 Job Number. Paae:12 of 19 1 C� 41 1� ENVELOPE MANDATORY MEASURES ENV -MM (PROJECT NAME DATE Hideawav Gate House 8/16/2004 DESCRIPTION Designer Enforcement ❑X §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. F§`1`18(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, Basketed, weatherstripped or otherwise sealed. 0 § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows Installed shall have air Infiltration rates not exceeding those shown In Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. X] §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an installed R -value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySott User Number. 5862 Job Number. Page: 13 of 19 TAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG4 PROJECT NAME DATE Hideawav Gate House I 8/16/2004 1. Watts for Illuminance Categories A -D (from column G) 59watts 2. Watts for Illuminance Categories E -I (from LTG -4 Part 2) Q Watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) --701+1 01+1 0 = I 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3)59 watts 1 MIL..VIRLL! L.r{! - OIu111111a1lVC VaLV9W11C.7 401W Y allu Vr V33 Q421tl3 peva a © a a a o a ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) Gate House Transportation Te►minals_Waiting Room &Lounge C 0.00 98 0.60 59 BUILDING PAGE TOTAL TOTAL 98 1 59 2O1 59 SF WATTS EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 14 of 19 LIGHTING MANDATORY MEASURES i LTG -MM PROJECT NAME DATE Hideawav Gate House I 8/16/2004 DESCRIPTION Designer Enforcement X§ 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 118 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. , § 131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system Is provided with a manual, accessible override switch In sight of the lights. The area of override is not to exceed 5,000 square feet FV -1 § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. X] § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. ❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. § 131(a) Individual Room/Area Controls: Each room and area in this building Is equipped with a separate switch or occupancy sensor device for each area with floor -to -calling walls. § 131(b) Uniform Reduction for individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bl-level switching for uniform reduction of lighting within the room. a§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight In the area shall have 50% of the lamps In each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot Diagram of shading during different times of the year Is Included on plans. FV I IAI §131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel Inside the building are controlled with a directional photo cell control on the roof and a corresponding relay In the electrical panel, or uses an astronomical time clock. ❑ § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. ❑ § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:15 of 19 r� U • • MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Hideaway Gate House I 8/16/2004 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies FXJ §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. R§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be Insulated In accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: 0 § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours N power is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or F] § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. 6122(o)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves of dampers, that allow the supply of heating or cooling to be setback or shut off independently of other Isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. N-09 § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 16 of 19 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE Hideaway Gate House I 8/16/2004 Description Designer Enforcement Ventilation FX § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. FXJ § 1220 Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1988); or 0 § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 12l(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 If a circulating hot water system Is Installed, It shall have a control capable of automatically turning oft the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. rVI IAI§ 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallonsicycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallonsicycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.6 gallons per minute, and 0.75 gallonsicycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 17 of 19 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway Gate House 8/16/2004 SYSTEM NAME FLOOR AREA Trane Mini-SDIR Svstem 120 Number of Systems 1 Heating System Output per System 8,000 Total Output (Btuh) 8,000 Output (Btuh/sgft) 66.7 Cooling System Output per System 2,100 Total Output (Btuh) 2,100 Total Output (Tons) 0.2 Total Output (Btuhlsgft) 17.5 Total Output (sgWon) 685.7 Air System CFM per System 525 Airflow (cfm) 525 Airflow (chn/sgft) 4.38 Airflow (cfmrron) 3,000.0 Outside Air (%) 21.0 Outside Air (ctmisgtt) 0.92 Note: values above given at ARI conditions 24.0 of Outside �� 110 cfm 69.6 of 12.0 / 78.5 of Outside 110 cfm 74.5/68.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I I COIL HTG. PF_AF( CFM I Sensiblel Latent I I CFM I Sensible -97 5,441 792 109 4,658 0 272 233 0 0 110 4,456 -233 110 5,414 0 0 272 233 1044 559 10 537 Trane Mini -Split System 2,057 0 0 Total Adjusted System Output 2 057 0 0 (Adjusted for Peak Design Conditlons) TIME OF SYSTEM PEAK F Jul 3 pm Jan 12 am 60.0 of110.0 of Heating Coil 82.3 / 70.9 of Supply Fan 525 cfm 110.0 of —� Supply Air Ducts 109.6 of ROOMS 70.0 of h Return Air Ducts `S 78.7 / 69.6 of Cooling Coil Supply Fan 525 cfm 78.7 / 69.6 of Supply Air Ducts 79.2 / 69.7 of 76.5% R.H. ROOMS 74.0 / 68.6 of h Return Air Ducts `i I EnemvPro 3.1 By EneravSoft User Number. 5862 Job Number. Paae:18 of 19 1 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:19 of 19 PROJECT NAME Hideaway Gate House DATE 8/16/2004 SYSTEM NAME Trane Mini -Split System FLOOR AREA 120 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Gate House Gate House 1 -971 5,441 792 -971 5,441 792 109 4,658 • PAGE TOTAL 1 -971 5,441 792 109 4,658 TOTAL 1 -9711 5,441 792 109 4,658 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:19 of 19 �!l U' /'rcw � CCD tx�pGyy 1 Total Permit Fees City of La Quinta r Building 8 Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico ��X La Quinta, CA 92253 - (760) 777-7012 Buildin Permit Application pplication and Tracking Sheet X Project Address: —311 5`L O„rcr*s Name: � �l nrl•' A. P. Number: 1 _ -03 X23 (.� Address: r - Legal Description: � e- t� 3 Cin•. ST. Zip: X Contractor: LAIIsan ' !• Telephone: a �!j • ---2 c:'•.� -• .a x Address: .": r r Project Description: �►v f J� Cin•. ST. Zip: _� X Telephone: a?717StateLic.#:Citv Lic. #: Arch., Engr., Designer: l o� Address: 39 1`t City. ST. Zip: S, ,4 Mr / ? i Telephone: O ,_ _ "w :^._ - Construction T r �• , _ - YPe' v �� Occupancy: +120 � - State Lic. #: �'�` _ _ Project type (circle one): eAdd'n A Alter Repair Demo Name of Contact Person: •(' Sq. Ft.: (2USO� Stories: #Units: X Telephone # of Contact Person: /-/ - , stimated Value of Project: 5 Q0 '02— APPLICANT: DO NOT WRITE BELOW THIS LINE PERMIT FEES TS.ubmi,tal Req'd Recd TRACKrNG Plan Check submitted So Item ucural Cala. Amount Reviewed, ready for corrections S Plan Check Deposit Trutt Calcs. Called Contact Person G• • Plan Check Balance Energy Calts. Plans picked up Construction Flood plain plan Plans resubmitted 0 Mechanical Grading pl2n2' Review, ready fo orrecti ue I Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up J �C tU e 6 S.l►1.1. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '" Review, ready for correctionstiissue Developer Impact Fee • Planning Approval -, Called Contact Person Y/ A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees �!l U' /'rcw � CCD tx�pGyy 1 Total Permit Fees Coachella Valley Unified School District P.O. Box 847, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Owner's Name: Pruiect Address: Hideway Tt�s Box For District Use Only DtYOOPER FEES PAID 11111111111111 IIII11111111I 28 IE CERTIFICATE OF COMPLIANCE (California Education Code 17620) ND La Quinta Partners, LLC 80-391 Avenue 52 La Quilita, CA Project Description: I Hideway Gate House �APN- 772-410-038 Tract Type of Development Date August 20, 2004 Phone No. Lot #'s: Residential XXX Commercial Industrial Total Square Feet of Building Are 120 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: August 20, 2004 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code 17620 65995 Project Agreement Existing Approval Prior to 1/1/87 Note: Number of Sq.Ft.120 Amount per Sq.Ft. 0 Amount Collected 0 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: Not Subject to Fee Requirement NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form tables.doc 1/16/03 T AMOUNT LEVEL ONE AMOUNT LEVEL UNT; MITIGATION AMO CONINVIN0. AMOUNT: DATR CERTIFICATE OF COMPLIANCE (California Education Code 17620) ND La Quinta Partners, LLC 80-391 Avenue 52 La Quilita, CA Project Description: I Hideway Gate House �APN- 772-410-038 Tract Type of Development Date August 20, 2004 Phone No. Lot #'s: Residential XXX Commercial Industrial Total Square Feet of Building Are 120 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: August 20, 2004 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code 17620 65995 Project Agreement Existing Approval Prior to 1/1/87 Note: Number of Sq.Ft.120 Amount per Sq.Ft. 0 Amount Collected 0 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: Not Subject to Fee Requirement NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form tables.doc 1/16/03 T om Tisdale "ire Chief I Proudly serving the wiincorporated areas of Riverside County and the Cities of: Banning Beaumont Calimesa Canyon Lake Coachella Dessert Hot Springs r. Indian Wells 4. Indio .;. Lake Elsinore 4cs La Quinta 4 - Moreno Valley .;. Palm Desert ., Perris 4. Rancho Mirage 4. San Jacinto g. Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8686 • Fax (760) 863-7072 March 15, 2004 Nick Fullerton Architects 8000 Hwy 35, Ste. 3 Bigfork, MT 59911 Re- Non -Structural Building Plan Review LAQ-04-TI-038 / Hideaway CC Ave 52 Gatehouse Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit. 1) The Fire Department is required to set a minimum fire flow for the remodel or construction of all commercial buildings using the procedure established in the 2001 CFC. A fire flow of 1500 gpm for a 2 -hour duration at 20 psi residual operating pressure must be available before any combustible material is placed on the job site. 2) The required fire flow shall be available from a Super hydrant(s) (6" x 4" x 21/2" x 21/2') located not less than 25' or more than 165' from any portion of the building(s) as measured along approved vehicular travel ways. 3) Power Operated Gates - Install Knox key operated switches, series KS -2P with dust cover, mounted per recommended standard of the Knox Company. Special forms are available from this office for the ordering of the Key Switch. This form must be authorized and signed by this office for the correctly coded system to be purchased. 4) Install portable fire extinguishers per Title 19, but not less than 2A1 OBC in rating. Contact certified extinguisher company for proper placement of equipment. Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Sincerely, FRANK KAWASAKI Chief Fire Department Planner By T Walter Brandes Fire Safety Specialist Cc: City of La Quinta — Building Dept. HAPF—IMP DataUa QL*ftXPR0JECT51DU1&V PC11AQ-04-TI-M.doc EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2"d R., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 } Coachella Valley Unified School District P.O. Box 847, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 TI -0 Box For District Use Only D O R FEES PAID 1111 IIIIIII111EI11111 28 IE ', r , AMOUNT LEVEL ONE AMOUNT: LEVEL UNT: MITIGATION AMOUN/: COMM/MD. AMOUNT: ND La Quinta Partners, LLC 1 Project Address: DATF. .f.F.IP IN IS' APN: 772410-038 1 Tract Lot #'s: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Hideway Date Phone No. August 20, 2004 Owner's Name: ND La Quinta Partners, LLC Project Address: 80-391 Avenue 52 La Quinta, CA Project Description: Hideway Gate House APN: 772410-038 1 Tract Lot #'s: Type of Development: Residential I XXX Commercial Industrial Total Square Feet of Building Are 120 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on b half of the owner/developer. Dated: August 20, 2004 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code 17620 65995 Project Agreement Existing Approval Prior to 1/1/87 Note: Number of Sq.Ft. 120 Amount per Sq.Ft. 0 Amount Collected 0 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: Not Subject to Fee Requirement NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form tables.doc 1/16/03 T Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning ¢• Beaumont 4. Cahmesa Canyon Lake 4. Coachella Desert Hot Springs 4. Indian Wells 4. Indio 4 - Lake Elsinore La Quinta 4. Moreno Valley Palm Desert 4. Perris .;. Rancho Mirage q. San Jacinto Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 82-675 Highway 111, 2nd Fl., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 March 15, 2004 Nick Fullerton Architects 8000 Hwy 35, Ste. 3 Bigfork, MT 59911 Re: Non -Structural Building Plan Review LAQ-04-TI-038 / Hideaway CC Ave 52 Gatehouse Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit. 1) The Fire Department is required to set a minimum fire flow for the remodel or construction of all commercial buildings using the procedure established in the 2001 CFC. A fire flow of 1500 gpm for a 2 -hour duration at 20 psi residual operating pressure must be available before any combustible material is placed on the job site. 2) The required fire flow shall be available from a Super hydrant(s) (6" x 4"x 21/2"x 21/2') located not less than 25' or more than 165' from any portion of the building(s) as measured along approved vehicular travel ways. 3) Power Operated Gates - Install Knox key operated switches, series KS -2P with dust cover, mounted per recommended standard of the Knox Company. Special forms are available from this office for the ordering of the Key Switch. This form must be authorized and signed by this office for the correctly coded system to be purchased. 4) Install portable fire extinguishers per Title 19, but not less than 2A1 OBC in rating. Contact certified extinguisher company for proper placement of equipment. Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Cc: City of La Quinta — Building Dept. HAPEMP Data%La QWntaLPR0JECTS1 ukbg PMLAQ44J -=.dx Sincerely, FRANK KAWASAKI Chief Fire Department Planner By Walter Brandes Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 21d FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072