Loading...
11-0952 (SOL) 11111111111111111111111111 03 lc&t!t 4 4a Qum& ' I P.O. BOX 1504 - �E VOICE(760)777-7012 78-495 CALLE TAMPICO FAX(760)777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING&SAFETY DEPARTMENT INSPECTIONS(760) 777-7153 BUILDING PERMIT - Date: 10/27/11 Application Number: 11-00000952 Owner: Property Address: 81600 AVENUE 58 IMPERIAL IRRIGATION DIST APN: 764-010-012- - P O BOX 987 Application description: SOLAR IMPERIAL, CA 92251 D 0 Property Zoning: UNKNOWN Application valuation: 81000 Contractor: ° OCT ?0 201 t Applicant: Architect or Engineer: KANNING, JEREMY j 13415 PROSPECTRO ROAD ; CITY OF LA QUINTA VICTORVILLE, CA 92392 FINkNCEDEPT N� (866) Ti 87 LiC. NOo.. :: 942589 589 ------------ ----------------- - -------------- ---------- --- --------- - -- -----=---- ------------------ LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under-penalty of perjury that I am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000)of Division 3 of theusiness and Professionals Code,and my License is in full force and effect. _ I have and will maintain a certificate of consent to self-insure for workers'compensation,as provided License Cl ss: C46 License No.: 942589 for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Date: Contractor: _ I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor K Code,for the performance of the work for which this permit is issued. My workers'compensation O ER-BUILDER DECLARATION insurance carrier and policy number are: 1 hereby affirm under penalty of perjury t I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 4970001999 following reason(Sec.7031.5,Business and Professions Code: Any city or county that requires a permit to _ I certify that,in the performance of the work for which this permit is issued,I shall not employ any construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for the person in any manner so as to become subject to the workers'compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that,if I ould become subject to the workers'compensation provisions of Section License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or 3700 of the Labor de,I shall,y rthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by C any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500).: Date: z I Q 1 Applicant: (_) lx 1,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business and Professions Code: The WARNING: FAILURE TO SECURE WOR 'CO P NSATION COVERAGE IS UNLAWFUL,AND SHALL Contractors'State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINALy NALTI NO CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees,provided that the - DOLLARS($100,0001 IN ADDITION TO THE COs OF COMPENSATION,DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If,however,the building or improvement is sold within SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES. one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_1 l;as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the . 7044,Business and Professions Code: The Contractors'State License Law does not apply to an owner of conditions and restrictions set forth on this application. . property who builds or improves thereon,and who contracts for the projects with a contractor(s)licensed - 1. Each person upon whose behalf this application is made,each person at whose request and for pursuant to the Contractors'State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, 1_1 I am exempt under Sec. BAP.C.for this reason the owner,and the applicant,each agrees to,and shall defend,indemnity and hold harmless the City of La Quinta,its officers,agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within ta0 days trom date of issuance of such permit,or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued(Sec.3097,Civ.C.). city and county ordinances and state laws relating to b 'Iding construction,and hereby authorize representatives of this co my to enter upon the above-mentioned prop for'n ection purposes. Lender's Name: Date: Q Signature(Applicant or Agent): Lender's Address: LQPERMIT Application Number . . . . . 11-00000952 Permit . . SOLAR PERMIT Additional desc . Permit Fee . . . . 28.50 Plan Check Fee 7.13 Issue Date Valuation 81000 Expiration Date 4/24/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA SOLAR COLLECTOR 1,001-2000 7.50 2.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS 6.00 ---------------------------------------------------=------------------------ Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee 33.50 Plan Check Fee 8.38 Issue Date Valuation 0 Expiration Date 4/24/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 7.50 1.00 11.0000 EA ELEC MISC 11.00 ---------------------------------------------------------------------------- Special Notes and Comments 14.4kW SOLAR ARRAY - (60) 240W PHONO PANELS W/ (2) 5,OOOW SMA INVERTERS [1,020SF] PLAN APPROVED WITH COMMENTS. 2010 CALIFORNIA ELECTRICAL CODE. October. 27, 2011 8:10:56 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 4.00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- --------7- Permit Fee Total 62.00 .00 .00 62.00 Plan Check Total 15.51 .00 .00 15.51 Other Fee Total 4.00 .00 .00 4.00 Grand Total 81.51 .0'0 .00 81.51 LQPERMIT I IOZ/tbI/6 " upzooaz�goda��a�—ad��a8uzzluoo—uoi�o�a8—�uaTl�ag�dsf�zodaz�dsf�zzoo�sanbl�aa ozd//:du IoawiW�af I! Tid MoZ Z"l3 s.W8(si 1 � to 1 Y411� '& SPA W` 3 . WA rt MI v. 3 Ilte: VI11��^,t�g 3 a �w w x s bh�}S6r gVIM ti 3 t� 3 i £991-£9ZZ6 VO'` JLNino v-1'3AV H189 00948 i LJOlsSOjOJ ,js E I iHParoli(}iadadgod a acv podaN snid deW}aaaay £Jo Z aged ijoda21 - ®uzoo•Ismi,)pa% N z . P.O. Box 1 504 BUILDING & SAFETY DEPARTMENT �� Ow 78-495 CALLE TAMPICO (760) 777-7012 OF T1 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To CDD: ctl iq Rill _ From: Les Johnson, Director-Planning Due Date: /IcW Permit#: Status: 151 "taj Building Flans Approval .(This is an approval to issue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: � �>D w&OUKT 50UML Address or General Location: $1_bjp ;,, Applicant Contact: )eaa& ,f 44.wm�.4& The Planning Department finds that: ...these Building Plans do not require Planning Department approval. ❑ ...these Building Plans are approved by the Planning Department. ❑ ...these Buildi Plans require corrections. Please forward a copy of the attach d corr ctions to the applicant. When the corrections are made please return hem to the Planning Department for review. Leshnson, D -Planning Date reCIVd SEP 14 2011 Clty of to Quinta Planning[)OPartment 4 T_ MEMORANDUM S ' OF f4 Off' TO: Building and Safety Department FROM: Jay Wuu, Associate Planner DATE: September 15, 2011 SUBJECT: 81-600 AVENUE 58 GROUND MOUNTED SOLAR SYSTEM Please observe the following California State Code: CAL. GOV. CODE § 65850.5 : California Code - Section 65850.5 (a)The implementation of consistent statewide standards to achieve the timely and cost-effective installation of solar energy systems is not a municipal affair, as that term is used in Section 5 of Article XI of the, California Constitution, but is instead a matter of statewide concern. It is the intent of the Legislature that local agencies not adopt ordinances that create unreasonable barriers to the installation of solar energy systems, including, but not limited to, design review :for aesthetic purposes, and not unreasonably restrict the ability of homeowners and agricultural and business concerns to install solar energy systems. It is the policy of the state to promote and encourage the use of solar energy systems and to limit obstacles to their use. It is the intent of the Legislature that local agencies comply not only with the language of this section, but also the legislative intent to encourage the installation of solar energy systems by removing -obstacles to, and minimizing costs of, permitting for such systems. (b)A city or county shall administratively approve applications to install solar energy systems through the issuance of a building permit ' or similar nondiscretionary permit. Review of the application to install a, solar energy system shall be limited to the building official's review of whether it meets all health and safety requirements of local, state, and federal law. The requirements of local law shall be limited to those standards and regulations necessary to ensure that the solar -energy system will not have a specific, adverse impact upon the public health or safety. However, if the building official of the city or county has a good faith belief that the solar .energy system could have a specific, adverse impact upon the public health and safety, the city or county may require the applicant to apply for a use permit. MA city or county may not deny an application for a use permit to install a solar energy system unless it makes written findings based upon substantial evidence in the record that the proposed installation would have a specific, adverse impact upon the public health or safety, and there is no feasible method to satisfactorily mitigate or avoid the specific, adverse impact. The findings shall include the basis for the rejection of potential feasible alternatives of preventing the adverse impact. (d)The decision of the building official- pursuant to subdivisions (b) and (c) may be appealed to the planning commission of the city or county. (e)Any conditions imposed on an application to install a solar energy system shall be designed to mitigate the specific, adverse impact upon the public health and safety at the lowest cost possible. (f►(1 )A solar energy system shall meet applicable health and safety standards and requirements imposed by state and local permitting authorities. (2)A solar energy system for heating water shall be certified by the Solar Rating Certification Corporation (SRCC) or other nationally recognized certification agency. SRCC is a nonprofit third party supported by the United States Department of Energy. The certification shall be for the entire solar energy system and installation. (3) A solar energy system for producing electricity shall meet all applicable safety and performance standards established by the National Electrical Code, the Institute of Electrical and Electronics Engineers, and accredited testing laboratories such as Underwriters Laboratories and, where applicable, rules of the Public Utilities Commission regarding safety and reliability. (g)The following definitions apply to this section: (1)"A feasible method to satisfactorily mitigate or avoid the specific, adverse impact" includes, but is not limited to, any cost-effective method, condition, or mitigation imposed by a city or county on another similarly situated application in a prior successful application for a permit. A city or-county shall use its best efforts to ensure that the selected method, condition, or mitigation meets the conditions of subparagraphs (A) and (B) of paragraph (1 ) of subdivision (d) of Section 714 of the Civil Code. (2)"Solar energy system" has the same meaning set forth in paragraphs (1 ) and (2) of subdivision (a) of Section 801 .5 of the Civil Code. (3)A "specific, adverse impact" means a significant, quantifiable, direct, and unavoidable impact, based on objective, identified, and written public health or safety standards, policies, or conditions as they existed on the date the application was deemed complete. If you have any questions, please contact me at 760-777-.7125. Bin.# City, of La Quints Building a Safety Division Permit# P.O. Box 1504, 78-495 Calle Tampico La Quinta,CA 92253-(760) 777-701.2 . Building Permit Application and Tracking Sheet Project Address: & �� ���/SU E Owner's Namc TP x A.P.Number: Address: 85- C AY S', Legal Description: City,ST,Zip:(5C rewwL 04 ZZ 1/3 Contractor: J ew Fhy IeA N N i-i Ir Telephone:7160—M-300 Address: 3 f//S fowdspec—fwt fee, Project Description: City,ST,Zip: 1C7nrt UICLC GR04N� 1104�T U cSQC,�j2 sr� W o-6/ -6 81-6 ��: ,;. . .::. . Telephone: �-...:,� .::>:3:;�,..:. a,->:�=.; O a � t�tp ��v��, fist:'�;::,:�.,�,�:�: `x State Lic.#: 9 2�9 City Lic.#: Low 3OF 14.4 (056aPMJx*%• Arch.,Engr.,Designer. Address: City,Sf,Zip: Telephone: `' .• >.', ` Construction Type: Occupancy: .State Lic-#: ":.— ••;wAf"= ..� °�' `` Project circle one): New Add'n Alter Repair Demo Name of Contact Person: Er?C ,V Arjailo, G Sq.Ft.: #Stories: #Units: Telephone#of Contact Person: W Q— 614—60S'6 Estimated Value of Project: 4,01 4 f APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Reed TRACKMG PERMIT FEES Plan Sets 3 Plan Check submitted / Item Amount Structural Cala. Reviewed,ready for corrections Plan Check Deposit Truss Cala. Called Contact Person Plan Check Balance ^ Title 24 Cala. Plans picked up 11- Construction •�; '1,� Flood plain plan Plans resubmitted Mechanical p .... Grading plan r Review,ready or rr e Jb lot( Electrical Subcostactor List Called Contact Pe- Plumbing Grant Deed Plans picked up H.O.A.Approval Plans resubmitted �$ Grading IN HOUSE:- '''Review,ready for correctio ue a 20.1 Developer impact Fee Planning Approval Called Contact Person A.I.P.P. Pub.Wks.APpr Date of permit issue School Fees Total Permit Fees dAAA- R8Wf rb A4h. rt t&A q Ir l ­4 We )MA,& �j7�,,� �. yt,�.t h--AA- . �s�S�go�i -SQA- fw IIIIIIIIIIIIIIIIIIIIIIIII 04 rr IE I JK Solar 13415 Prospector Rd. Victorville, CA 92392 Date: August 23, 2011 Project: Imperial Irrigation-'District , 81600 581 Ave., La Quinta,-CA 92253 Attached is an image of the site as it exists. Plans and manufacturer cut sheets are also attached. System warning and rating must be labeled at utility disconnect, plus sizing of existing electrical panel. System requires 30 amp and 40 amp breakers in a subpanel at array 1. Existing 400 amp panel 2. (2) SMA Sunny Boy Inverter(s); (1) @ 5000W and (1) @ 7000W US specification 3. (60) Phono Solar modules 240 watt 4. ProSolar ground mounting specifications included � 4�•o95ti CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE O BY Jeremy Kanning 760-617-6856 CA License #942589 [SEP O 1 2011 Warning labels for PV system All lettering shall be in white with red backround Letters shall be 3/8" all,capitals. At service panel: WARNING ELECTRICAL SHOCK HAZARD LINE AND LOAD SIDE MAY BE ENERGIZED PV SOLAR BREAKER DO NOT RELOCATE At lockable system disconnect: PV SYSTEM A.C. DISCONNECT CITY OF LA QUINTA At Inverters: BUILDING & SAFETY DEPT. PV SYSTEM APPROVED FOR CONSTRUCTION D.C. DISCONNECT DATE BY im '2 . Y At Inverters cont. RATED MPP CURRENT 8.06A RATED MPP VOLTAGE 357.6V MAX. SYSTEM VOLTAGE 600V MAX. SHORT CICUIT CURRENT 17A A.C.POINT OF CONNECTION A.C. OUTPUT CURRENT 25A NOMINAL A.C. VOLTAGE 277V CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY { SUNNY BOY 5000US / 6000US / 700OUS > UL 1741/IEEE 1547 compliant > 10 yr. standard warranty > Highest CEC efficiency in its class > Integrated load-break —�• ••;� rated AC and DC disconnect switch u` > Integrated fused series string combiner > Sealed electronics enclosure &Opticool > Comprehensive SMA communications and — - data collection options V �' > Ideal for residential or 4 commercial applicatioes , > Sunny Tower compatible SUNNY BOY 500OUS / 600OUS / 700OUS The best in their SMA is proud to introduce our new line of inverters updated with our latest technology and designed specifically to meet IEEE 1547 requirements.The Sunny Boy 6000US and Sunny Boy 7000US are also compatible with SMA's new Sunny Tower. Increased efficiency means better performance and shorter payback periods.All three models are field-configurable for positive ground systems making OA L us them more versatile than ever.With over 750,000 fielded units,Sunny Boy has become the benc`mark for PV inverter performance and reliability throughout the world. Technical Data SUNNY BOY 5 000 U S / 6000 U S / 7000 U S SB 5000US SB 6000US SB 7000US Recommended Max.PV Power(Module STC) 6250 W 7500 W 8750 W Max.DC Voltage 600 V 600V_ 600V Peak Power Tracking Voltage 250-480 V 250-480 V 250-480 V DC Max.Input Current 21 A 25 A 30A DC Voltage Ripple <5% <5% <5% s Number of Fused String Inputs 3(inverter),4 x 15 A 3(inverter),4 x 15 A 3(inverter),4 x 15 A (DC disconnect) (DC disconnect) (DC disconnect) PV Start Voltage 300 V 300 V 300 V AC Nominal Power 5000 W 6000 W 7000 W a AC Maximum Output Power 5000 W 6000 W 7000 W AC Maximum Output Current(@ 208 240,277 V) 24 A,21 A,18 A 29 A,25 A,22 A 34 A,29 A,25 A It AC Nominal Voltage/Range 183-229V@208V 183-229V@208V 183-229V@208V 211-264 V @ 240 V 211-264 V @ 240 V 211-264 V @ 240 V 244-305 V @ 277V 244-305 V@ 277 V 244-305 V@ 277V AC Frequency/Range 60Hz/59.3Hz-60.5Hz 60 Hz/59.3 Hz-605 Hz 60Hz/59.3Hz-605Hz ¢ Power Factor 0.99 @ nominal power 0.99 @ nominal power 0.99 @nominal power Peak Inverter Efficiency 96.8% 970% 971 % CEC Weighted Efficiency 95.5%@ 208 V 95.5%@ 208 V 95.5% 95.5%@ 240 V 96.0%@ 240 V 96.0%@ 277 V 96.0%@ 277 V Dimensions W x H x D in inches 18A x24.106 18A x24.1 x95 18A x24.1 x95 Weight/Shipping Weight 141 lbs/148 lbs 141 lbs/14816s 141 lbs/148 lbs Ambient temperature range -13 to+113 gF -13 to+113 FF -13'to+113 gF Power Consumption:standby/nighttime <7W/0.1 W <7W10.1 W <7 W/0.1 W �€ Topology Low frequency transfor- Low frequency transfor- Low frequency transfor- mer,true sinewave mer,true smewave mer,hue sinewave e Cooling Concept Opficool, OptiCool, Opticool, - forced active cooling forced active cooling forced active cooling % Mounting Location Indoor/Outdoor(NEMA 3R) 0/4* •/• LCD Display • • • € Lid Color:aluminum/red blue/yellow O/O/O/O •/O/O/O •/O/O/O Communication:RS485/Wireless O%O C)/ O%O e Warranty:l0-year • • • Compliance:IEEE-929,IEEE-1547,UL 1741,UL 1998,FCC Part 15 A&B • 1 • 1 • F Specifications for nominal conditions •Included O Option — Not available Efficiency Curves98 96 — ... de 97_� _ �_ _ Urv-750VDc --- U, 310 V DC �a.oadm++t�y eo.�b.a K b dam mag.and t1! 86 }f low 7000 30004000 5000 6000 9000 ,.1: .. PK lwl www.SMA-America.com Phone 916 625 0870 Toll Free 888 4 SMA USA SMA America, Inc. q Elektro Mustermann Musterstrafie 21 54321 Musterstadt Elektro Mustermann-Musterstralle 21-54321 Musterstadt Muster Inc. Tel.:+49 123 456-0 Mr Mustermann Fax: +49 123 456-100 MusterstraRe 1 E-Mail: info@el-mustermann.de 12345 Musterhausen Internet:www.el-mustermann.de System overview (United States Los Angeles) o -10°C...70°C String A Inverter Phono Solar 1 x Sunny Boy 5000US-240VAC PS240P-20/U Max.efficiency:96.8% Module x String: European standard efficiency:95.8% 12 x 2 Max.AC power: 5.10 kW Inclination/Azimuth: Max. DC power:5.30 kW 15°/0° Technical data Nominal power of PV-generator:5.76 kW Nominal power ratio:92% Total number of modules:24 Yearly en.yield(approx.)':8962.4 kWh Total surface of PV-generator:39.7 m= Energy usability factor:100.0% Number of inverters:1 Performance Ratio(approx.)':84% Max.DC power:5.30 kW Spec.energy yield(approx.)': 1556 kWh/kWp max.AC-Active power:5.10 kW Cable losses(%in PV-Energy):Not considered Inverter effectiveness:96.3% Notes: Room for your comments Signature' Important note:The calculation of the yield is based on estimated values and mathematical models.SMA is in no case liable for the real yield.which can e.g.deviate due to contamination or different efficiencies of the modules. V1.57 Check list: Project file: No file has bin saved with this configuration yet. System overview Inverter: 1 x Sunny Boy 5000US-240VAC Location: United States/Los Angeles PV-module temperatures PV module Minimum PV temperature: -10"C Phono Solar Design temperature: 50°C PS240P-20/U Maximum PV temperature: 70°C Angle of inclination:15° Azimuth angle:0" Technical . . ta Nominal power of PV-generator 5.76 kW Total surface of PV-generator 39.7 m' Number of inverters 1 Max.DC power 5.30 kW max.AC-Active power 5.10 kW Grid voltage 240 V Total number of modules 24 Nominal power ratio 92% (ok) String A: String power(input) 5.76 kW Powerratio(Input) 100% String MPP voltage at 15°C 373 V (ok) String MPP voltage at 50°C 318 V (ok) String MPP voltage at 70"C 287 V (ok) min.MPP voltage,set grid voltage:240 V 250 V String open circuit voltage at-10°C 506 V (ok) max.allowed DC voltage(Inv) 600 V Max.current of PV-generator 16.1 A (ok) Max.DC current permitted 21.0 A Number of strings(3 inputs) 2 Number of modules per string min=11;max--14 .12 r PV/Inverter compatible PV generator configuration and inverter type are compatible nominal power behavior(max.DC power invener/PV-peak power)is in the standard range (80%-120%). VDC,min VMPP,Deuen VDC,mox V V1.57 6 Elektro Mustermann MusterstraRe 21 54321 Musterstadt Bektro Musterrnann-MusterstraRe 21-54321 Musterstadt Muster Inc. Tel.:+49 123 456-0 Mr Mustermann Fax:+49 123 456-100 Musterstrafle 1 E-Mail: info@el-mustermann.de 12345 Musterhausen Internet:www.el-mustermann.de System overview (United States Los Angeles) o 3 10*C...70°C - String A Inverter Phono Solar 1 x Sunny Boy 7000US-240VAC PS240P-20/U Max.efficiency:97.1 % Module x String: European standard efficiency:96.0% 12 x 3 Max.AC power: 7.10 kW Inclination/Azimuth: Max. DC power: 7.42 kW 15°/0° Technical data Nominal power of PV-generator:8.64 kW Nominal power ratio:86% Total number of modules:36 Yearly en.yield(approx.)':13446.6 kWh Total surface of PV-generator:59.5 m' Energy usability factor: 100.0% Number of inverters:1 Performance Ratio(approx.)':84% Max.DC power:7.42 kW Spec.energy yield(approx.)':1556 kWh/kWp max.AC-Active power:7.10 kW Cable losses(%in PV-Energy):Not considered Inverter effectiveness:96.3% Notes: Room for your comments Signature' Important note:The calculation of the yield is based on estimated values and mathematical models.SMA is in no case liable for the real yield,which can e.g.deviate due to contamination or different efficiencies of the modules. V1.57 Check list: Project file:No file has bin saved with this configuration yet. System overview Inverter: 1 x Sunny Boy 7000US-240VAC Location: United States I Los Angeles PV-module temperatures PV module Minimum PV temperature: -10"C Phono Solar Design temperature: 50°C PS240P-20/U Maximum PV temperature: 70°C Angle of inclination:15° Azimuth angle:0° Technical data Nominal power of PV-generator 8.64 kW Total surface of PV-generator 59.5 m' Number of inverters 1 Max.DC power 7.42 kW max.AC-Active power 7.10 kW Grid voltage 240 V Total number of modules 36 Nominal power ratio 86% (ok) String A: String power(input) 8.64 kW Powerratio(Input) 100% String MPP voltage at 15"C 373 V (ok) String MPP voltage at 50°C 318 V (ok) String MPP voltage at 70"C 287 V (ok) min.MPP voltage,set grid voltage:240 V 250 V String open circuit voltage at-10°C 506 V (ok) max.allowed DC voltage(Inv) 600 V Max.current of PV-generator 24.2 A (ok) Max.DC current permitted 30.0 A Number of strings(3 inputs) 3 Number of modules per string min=11;max--14 12 PV/Inverter compatible PV generator configuration and inverter type are compatible nominal power 1 behavior(max.DC power inverter/PV-peak power)is in the standard range (80%-120%). voc, in VMP1,0e,19n VDC,mox V V1.57 Ph o • POLY CRYSTALLINE ® w IES 40 . High Performance Solar Panels Phono Solar's 210-240 Poly Series is a robust 60 cell PV panel designed for on-grid residential and commercial applications. Quality control measures and strict factory testing ensure that Phono Solar panels exceed customers expectations. Phono Solar Advantages Histor=y Phono Solar has been producing PV Modules since 2004. As part of the Sumec Group and the Sinomach family of businesses, Phono Solar is backed by parent companies with 15 Billion USD in annual sales revenue. Financia!Strar-,V,m As part of the Sumec and Sinomach family of companies,Sumec has the financial support of two of the oldest,most profitable companies in Asia. This is critical when considering that a PV module is meant to last at least 25-years.Customers can be assured Phono Solar will be around to honor its warranty commitment +amity Products a`_an.exCellBr:-i price Phono Solar modules cant'a S-1 C/PTCof 91%and module ef5ciency of 14.8%.This puts Phono Solar at the top of the CEC approved suppliers list. Higher efficiency modules lead to higher potential rebate=_.Phono Solar helps the customer maximize their system productivity_ Pariormance Excellent PTC ratings,efficient manufacturing facilries and industry-leading quality controls makes Phono Solar's modules the right choice for any installation_ Additionally,Phono Solar PV modules carry a 25-rear performance guarantee_ CGr;aci�� In relatively short time,Phono Solar has become one of the top exporters in the Solar Industry.Phono Solar's three production facilities will produce more than 50OMW of PV Modules in 2011_ a03 TVI o,—&,A.-iaric2 rt Fc.,�s With a North American sales office and Southern California based distribution center,we-offer logistical expertise for all regions within tie US customers are A Leader in Solar `WllanufaC' Llrillg supported by a team of dedicated industry professionals that value strategic business relationships and strive to maintain long.term partnerships. At Phono Solar,our mission is to provide our customers with the highest quality PV modules at the most competitive price-Our focus on quality has lead to our PV modules being used in installations War r-an f},r Conditions: worldwide.Our most recent installation is a 35MW r 5 years product warranty Solar Power plant in Veprek,Czech Republic,which is 25-year performance guarantee 00%up to 10 years,80%up to 25 years) the 9th largest solar power plant on earth. D,- Product certification to UL 1703 ;•. k 3x t> CEC(California Energy Commission)Program Registered b- Product certification to IEC 61215(ed.2) i Protection class Il/JEC 61730 CE conformity • > pass C Fire rating n FESC(Florida Solar Energy Center)PV Module Certification ' o O A I Assembly Notes See installation and operating 20V DC 1640(L) 992(tM 45 nen 27-Kg AmpFt35.4- 32mm manual at www.phonosolarusa.com/ MC4 64.6' 39.1" 1.8" 48.4lbs China (0.006 tempered Productstmodules inch2) glass 0- Horizontal and vertical assembly possible 01 System voltage max 600 V Performance passes 210wp 215wp 220wp 225wp 230w 235wp 240wp MEMMEMEM PTC Performance9-perauxe -40+85 'C 190.1 194.7 199.4 204.0 288.6 213-3 217.9 Hal diameter @ 8Wm/h Up to 25 mm ic Stn4tre 1' Glass-foil ► AnOdzed aturninum frame Conth x*wirw Up to 130 Km/h t. Jisxxion box OP)65 with 6 bypass lodes pressure b WeatheResistant bads sheet(white) b Cable 12 AWG(4mm) toad Capacity of Module Up to 30 Ib/ftr Celts 6 x 10 pieces in series . . ... .. Poly crystal Si 156mm x 156mm sgtrdre Weal;Light Performance EEectric31 Characteristics For STC t- 900 0.0 -20 PS21OP-20/U 21UW 28.6V 2354 36.5V 7 3% .D_0.- _ -0.9 40 90A t PS215P-20/U 400 -2-1 -60 215W 28.8V 7.47A 36.7V 800A :t3% PS220P--20/U 22OW200 -0.1 -90 29.0V 7.59A 36.91/ 8.10A t 3% PS225P--20/11 225W 292V 7.71A 370V 820A t 3% 100 -8.7 -90 PS230P-0/U 23OW 29AV 7" 37.1 V 8.30A t3% The electrical data applies for 25°C and AM 1.5. PS235P-20/U 235W 29.6V 7_244 373V 8.40A t 3% PS240P-20N 24UW 29.8V 8.06A 375V 8.50A +'3% Z'eae?-r:aa Ctlare,•±-enstcs Note:defined as standard deviation of#xxmands measurements.Absolute power values depend on the measuring System.They can differ by+/-5%from one measuring system to another. . . P Operating C a;actevistic Qui-•.';ares vii7? C!SEt�?s temperature range -05 to 85 IC 992 Temperature coefficient Pmpp -0.51%/K 7299 Temperature -0.37%/K o T-- coefficientVoc 1609 / �a09 /1 `':tlYr Temperature 2-04._ m `-' " ` ! coefficientlsc 0.03%/K 3.200 •`, 9=.9 �, - i , - tyro 1.60 9299 ` 0.000an 0.00 Lao 9.50 14.40 i920 24M 2-MI 33.69 U•V, • ® f, t OVE ?�2:`tr1Er 3:1iL2r1"11a�"li2ai � . �� Phono Solar North America 9595 Six Pines Drive,Suite 8210 The Woodlands,TX 77380 T 832-631-6333 SE I A`_" www.phonosolarusa.com 10 The Original "Top-Down"-PV Mounting System for Ground Applications Benefits of GroundTrac®Patent#6,360,491 .. Industry's preferred low,cost and easiest.to install ground mount-system Used for kW to Multi-MW projects • Patented ground mount system ships from available stock • Proprietary Drop-N-Lock rail insert drops in and locks ProSolar GroundTrac@ rails in place • Over 10 years of ProSolar's proven design • Pre-engineered and tested for easy permitting • No cross-bracing required [i O. J, o rS 10 - � ��`• ,a-,- :� L' .. r -n y.-' .rte_ ,""r"''""`+yw. professional SOLS or' ! products �_ - X 9., - - - - ,� •1. _. .. . See SOW { r �•. 12 •Y I"Min .. ONVonce depends ; I. ' on tilttiltalk 42" (see angle Curt) . Assemble re-usable grade stakes(ProSolar metal grade stake kit shown). Recommend 2"x 4"vertical support. Dig footings. Use '/z" drill bit and 9/16" socket to attach grade 1 Lateral (left to right) footing spans stake kit to 2" x 4". Attach 1" x 4" wooden horizontal listed on page 4 (bottom). Front to support using 3-1/2" (min.) C-clamps. Grade stake kit rear footing spans listed in angle includes: 24 threaded metal stake, aluminum spacer charts on page 4 (top). Refer to block, bolt and washer. engineering reports for footing specs. 3 Place horizontal 1-1/2" schedule 40 galvanized water pipe with slip-on Hollaender@ Tees. Adjust C-clamps i as necessary to level pipe. i C 31 I 1 1 - f Y rt .•r 1 1 4 + 1 1 5 4 Measure vertical pipe lengths, allowing 2" (min.) from bottom Insert vertical pipes into of footing to avoid pipe contact tees and fasten lower tee with moisture. set screw. Center pipes in footings by sliding left or right. Pour or pump mixed concrete into footings. 1� ..$��+°.x 'a `t y I'�f. x � .3t� �'4 +a•:� ?�,w```�I.r':t"" '!c wy+t e'2. �"` �.. 5 17 l L , r ' ��• �sw::'f••-rr+.tli. 5'rtY.,vyt`...b.Ae'K+!+.,k'i+4•"�"�-.w1""4�Y^`x'"'W"�'^N' .f.,`�'f�'S` ';'� 't x' x4�� a�•,L _.,^ ; +test ra�IQon topof horizontal pipes Run,string level `� '�� Omlop-or boxtom,toJalign.:tops ofrSuppo intpit raIIS. ,,;�.;�4 Fasten rail lace by usmg'Gro; undTrac® dnll:gwde.5 �N r 4y � , along top'd �ottom,of horizontal pipes Drill I {u Unbolt locking holes 1n'iO cekLeave at,ieast one dnll` -; guide...atttaiched after.jdrilling to'keep rall in place .r,F S,'S� �ya�,. .� �, y,r,�.'C Y✓(� r s.,+t m' s 1>,,�jk� �_ { c �_, ,6. Min. t 7i•'3r h 7kia'y+,lw n'r fs'ts'x .�,i,'r tx ailigv- •y' s -` .. � • , �, i}.ddr ai wt rrn1 s o f GroundTracs Drill Guide r'< Base and Drill Bit. Install at least one rail every 101 _ for proper pipe spacing. eo 7 Insert U-bolt into locking rail holes and place OpbonWSnow Drop-N-Lock insert into the rail. Remove LoadEnnanwr remaining drill guide and proceed with other rails. Remove grade stakes. 8 Tighten all tee set screws to 17 ft-lbs with torque wrench. Install remaining rails, evenly tightening ate„ U-bolt nuts. Pre-assemble clamping EZ rail hardware and install solar modules and EZ rail endcaps. Completed i endcap Install 1-1/2" plastic pipe 9 installation. endcaps for schedule 40 pipe as necessary. Professional 4roundrav SOLAR produ Installation Manual 124"x 2-1/2"Support Rail Supports up to(3) 39.5"Wide Modules Array Footing 124"and 136" Rail Angle Distance 300 o° 84" Angle Chart S. 84" a 1 I 10° 83'151 81"Y 3. ° 73" 5" 00 I ' 'r 124" - f-'--'-'----76" - -• -'-'-'- �j!t 79" !:I 60-148X• from tuD !-._---._._. 81".-.-._._._._.�I�� from top 2-1/2" of footi ...........83"'-'_—Y. --'-'-!d otfootlng 84" T I------------84"-'_'-_'-•_' ! --- - 84"---- 136"x 2-1/2"Support Rail Supports up to (4) 32.5"Wide Modules Y'R 124 and 136"Rath �Yr h tz , ��` "�� r�yx1 �yr ,� his � x �\tri�C�,f 3��,f r'+� �� �,, ��'i e,�S,�"t • 164"Rail > , r t Angle Chart Array Footing 136" Angle Distance 20° 0° 108" i 2-1/2" 50 108" Y. 84" T -70-w- 106 164"x 3"Support Rail } 20° 101" Supports up to(4)39.5"Wide Modules 5° 0. -10 '0 � r �''' . ",$', !----------1044"- ------ -'-- •4f •- ---106"•--'--_._,._.. _a c s�+ r '- n - •---.----'---108"--------_._.1 ---------'108"--------'-'- -?' �r-nX�.`��'� / / •e. �.�.3. {` 164j,Rallt- ��k+{ �% r vi s, 164ljn los GroundTraco Rail Sizes 124" x 2-1/2" 136"x:2-1/2" 164" x 3" Number of Modules (3) 39.5"wide (4) 32.5"wide (4) 39.5" wide modules modules modules Lateral footing span (max) 10' 10' 8' non-snow load Lateral footing span (max) 6' 6Not snowload 30 Ib/ft2 snowload rated Front to back footing spacing See Angle Chart See Angle Chart See Angle Chart Pre-slotted rails at: 84"on Center 84"on,Center 108"on Center Page 6 of 7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2009: All information contained in this manual is property of Professional Solar Products (PSP). TileTrac®is a registered trademark for PSP and is covered under U.S.patent#5,746,029.Roof Trac®and Fastlack®is a registered trademark for PSP and is covered under U.S.patent#6,360,497.Rev.082009' ' 1 1