Loading...
05-1953 (CONR) IIIIIII VIII III VIII IIII 09 P.O. BOX 1504 - IE 4. 4 " VOICE(760) 777-7012 78-495 CALLE TAMPICO FAX(760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING&SAFETY DEPARTMENT INSPECTIONS(760) 777-7153 BUILDING PERMIT Date: 11/04/05 Application Number: 05-00001953 Owner: Property Address: 81120 AVENUE 60 CORAL OPTION I APN: 764-210-010- - - 530 BEACON PKY W NO 900 Application description: NEW COMML - OTHER NON-RESIDENTIAL BIRMINGHAM, AL 35209 Property Zoning: LOW DENSITY RESIDENTIAL � Application valuation: 241120 Contractor: Applicant: Architect or Engineer,,-- DESIGN BUILD STRUCTURES, INC. 77980 WILDCAT DRIVE, SUITE. #2 PALM DESERT, CA 92211 (760)772-0800 Lic. No. : 447802 - -- ----- - - -------- -- -- - -------- - -- ---- - -------- -- - --- - ---------- - - --------- ----- ---------------- LICENSED CONTRACTOR'S DECLARATION . WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000)of Division 3 of the Business and Professionals Code,and my License is in full force and effect. _ I have and will maintain a certificate of consent to self-insure for workers'compensation,as provided License las : B Li-nse No.: 447802 for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Datej d' Contractor: _ I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. My workers'compensation OWNER-BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 1542188 following reason(Sec.7031.5,Business and Professions Code: Any city or county that requires a permit to _ 1 certify that,in the performance of the work for which this permit is issued,I shall not employ any construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for the person in any manner so as to become subject to the workers'compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that,if I should become subject to the workers'compensation provisions of Section License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or 3700 of the Labor Code,I shall forthwith c ply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500).: Date) Applicant: (_) I,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business and Professions Code: The WARNING: AI LURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL,AND SHALL Contractors'State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees,provided that the DOLLARS($100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If,however,the building or improvement is sold within SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES. one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_) I,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044,Business and Professions Code: The Contractors'State License Law does not apply to an owner of conditions and restrictions set forth on this application. .6, property who builds or improves thereon,and who contracts for the projects with a contractor(s)licensed 1. Each person upon whose behalf this application is made,each person at whose request and for pursuant to the Contractors'State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_) I am exempt under Sec. ,8.&P.C.for this reason a the owner,and the applicant,each agrees to,and shall defend,indemnify and hold harmless the City of La Quinta,its officers,agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued(Sec.3097,Civ.C.). city and county ordinances and state laws relating to building construction,and ereby authorize representatives of this oun y to a er upon the above-mentioned property for inspection purpos Lender's Name: Date Signature(Applicant or Agent): - Lender's Address: LQPERMIT r Application Number . . . . . 05-00001953 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . 1136.50 Plan Check Fee 738.73- Issue Date . . . . Valuation . . . . 241120 Expiration Date 5/03/06 Qty Unit Charge Per Extension BASE FEE 639.50 142 .00 3.5000 THOU BLDG 100, 001-500, 000 497.00 ---------------------------------------------------------------------------- Permit . . . ELEC-NEW COMMERCIAL Additional desc . Permit Fee 191.00 Plan Check Fee 47.75 Issue Date . . . . Valuation 0 Expiration Date 5/03/06 Qty Unit Charge Per Extension BASE FEE 15.00 8800.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 176.00 ---------------------------------------------------------------------------- Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 5/03/06 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit MECHANICAL Additional desc . Permit Fee . . . . 39.50 Plan Check Fee 9.88' Issue Date . . . . Valuation . . . . 0 Expiration Date 5/03/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH OTHER VENT SYSTEM 6.50 ---------------------------------------------------------------------------- Permit . . . PLUMBING Additional desc . LQPERMIT Y � Application Number . . . . . 05-00001953 Permit . . . . PLUMBING Permit Fee . . . . 175.50 Plan Check Fee 24.38 Issue Date . . . . Valuation 0 Expiration Date 5/03/06 Qty Unit Charge Per Extension BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 12.0000 EA PLB INTERCEPTOR 12 .00 1.00 3..0000 EA PLB WATER INST/ALT/REP 3 .00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.•00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH 37.50 2 .00 .7500 EA PLB GAS PIPE >=5 1.50 1.00 15.0000 EA PLB GAS METER . 15.00 ---------------------------------------------------------------------------- Special Notes and Comments Commercial Maintenance Building, 8, 800 sqft. Type VN Sprinkled, Mixed- Occupancy B/S-3 . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 73.87 ART IN PUBLIC PLACES-COM 1185.60 DIF-CIVIC CENTER- --_COMM __ _ .836_.00 ENERGY REVIEW FEE 73.87 DIF FIRE PROTECTION-COMM 281.60 STRONG MOTION (SMI) - COM 50.63 DIF STREET MAINT FAC-COMM 202.40 DIF TRANSPORTATION - COMM 15171.20 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1557.50 1 .00 .00 1557.50 Plan Check Total 820.74 .00 .00 820.74 Other Fee Total 17875.17 .00 .00 17875.17 Grand Total 20253 .41 .00 .00 20253.41 LQPERMIT IIIIIIIIIIIIIIIIIIIIIIIII 01 > E �� a�u,wcf`L.c fi � ��, Certicate of'04 Occu anc p Y 1vc•_&2elrry G� OF 9► Y p� Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was -in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 81120 AVENUE 60 Use classification: COMM Building Permit No.: 05-1953 Occupancy Group: B/S-3 Type of Construction: VN Land Use Zone:.RL Owner of Building: CORAL OPTION I Address: 530 BEACON PKY W NO 900 City, ST, ZIP: BIRMINGHAM AL 35209 By: S. WILLETT Date: 8-23-06 Building Officiaf POST IN A CONSPICUOUS PLACE J BUTLER MANUFACTURING COMPANY 7440 Doe Avenue A BlueScope Steel Company Visalia, California 93291 Phone: (559) 651-5312 Fax: (559) 651-5395 www.butlermfg.com TO: Chuck McBride DATE: 12/13/2004 Design Build Structures, Inc BLDR ORDER M N/A 77-980 Wildcat Dr. Suite 2 Palm Desert, CA 92211 BMC #: 124204 PROJECT: Andalusia to Coral Mountain La Quinta, California BUILDING SIZE UNIT 1: 40' ("x 220' 0" x 1_4' PLEASE FIND ENCLOSED THE FOLLOWING INFORMATION PER YOUR REQUEST: 3 SETS STAMPED DESIGN DATA 3 SETS STAMPED DESIGN DWGS (EACH PAGE) 1 LETTER OF CERTIFICATION FOR LOADING REMARKS: r4w, CORDIALLY YOURS: Gary D. Nethery, E.I.T. (559)651-5344 005 CITY OF LA QUINTA 51 BUILDING & SAFETY DEPT. Pei ON o P oROVE�D g� DAT �'v -- BY Scs-r- �r R--�n TITLE 24 REPORT Title 24 Report for: Andalusia Maintenance Building @ Coral Mountain Indio, CA 92201 Project Designer: Design Build Structures, Inc. 77-980 Wildcat Dr. #2 Palm Desert, CA 92211 760-772-0800 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 LDATE-�o OF � ��IDE Job Number. G��®VE® JJ=== �0 ONSTRUCT{ON BYDate: 1/12/2005 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. L EnergyPro 3.1 By EnergySoft Job Number: User Number 5862 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -3 Proposed Construction Assembly Form ENV -MM Envelope Mandatory Measures Form LTG -4 Tailored LPD Summary and Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 13 15 16 17 18 20 21 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5862 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PER KVJM, 1 IVAIYItUH 1 C - Andalusia Maintenance Building @ Coral Mountain 1/12/2005 'ROJECT ADDRESS Indio 'RINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # Design Build Structures, Inc. 760-772-0800 f iOCUMENTATION AUTHOR TELEPHONE Checked by/Date G.R. Rose CAD Design (760) 345-4859 Enforcement Agency Use GENERAL INFORMATION' This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR DATE OF PLANS DAT Gina Rose BUILDING CONDITIONED FLOOR AREA 570 Sq•Ft. CLIMATE ZONE 15 BUILDING TYPE for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this NONRESIDENTIAL, E] HIGH RISE RESIDENTIAL a HOTEL/MOTEL GUEST ROOM, PHASE OF CONSTRUCTION _ ❑ F-1 • ':I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to NEW CONSTRUCTION ADDITION ❑ ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR ISIGNAT R ,/� DAT Gina Rose The Principal Designers hereby certify that the proposed building design represented in the construction documents add modelled ' for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. , ENV. LTG. MECH. ❑ F-1 • ':I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. ❑ 0 2.1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section' 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and.that I am a licensed contractor preparing documents for work that I have contracted to perform. y ❑ F] ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document , because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE ' Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME I A LIC. N0. DATE Desi - n Build Structures Inc.X Z O 18 05 LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1 "Required Forms PRINCIPAL LIGHTING DESIGNER - NAME • SIG U LIC: NO. DAT G G� IMECHANICAL COMPLIANCE OF Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2, MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER- NAME SIG A E LIC. NO. DAT ' GR Rose CAD Design - �- 3`3OS-S l2 GS Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By Energysoft User Number: 51362 Job Number: Page:3 of 21 r .r PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PERF -1 Andalusia Maintenance Buildinq (- Coral Mountain DATE 1/12/2005 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance ENERGY COMPONENT Design Design Margin [ standam Proposed H -MV Space Heating 12.11 8.95 3.16 Space Cooling 110.53 100.53 10.00 SOie`° 0 Indoor Fans 0.00 0.00 0.00 ^°-° - Heat Rejection 0.00 0.00 0.00 Hem R4ton .. Pumps & Misc. 0.00 0.00. 0.00 Domestic Hot Water 0.00 0.00 0.00 6HIW Lighting 32.63 32.63 Receptacle Process - 0 10 20 30 40 50 60 70 80 90 100 110 • .TOTALS: 163.68 150.53 13.16 kBlWsgft•yr a Percent better than Standard: 8.0% ( 8.0% excluding process)( 8.5% excluding process & receptacle) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Southwest 225 deg Conditioned Floor Area 570 sqft. 1 Number of Stories Unconditioned Floor Area o sqft. 1 Number of Systems Conditioned Footprint Area 570 sqft. 1 Number of Zones Orientation Gross Area Glazing Area Glazing Ratio 500 18 3.6% Front Elevation Southwest sqft. sqft. 130 0 0.0% Left Elevation (Northwest) sqft. sqft. 500 0 0.0% . Rear Elevation Northeast sqft. sqft. 130 0 0.00/p Right Elevation Total Roof (Southeast) sgft. sqft. sqft. sgft. sqft. sqft. 1,260 18 1.4% 570 0.0% Standard Proposed Lighting Power Density 1.100 W/sgft. 1.100 W/sgft. " Prescriptive Env. Heat Loss 286 176 Prescriptive Env. Heat Gain 27,360 12,757 Remarks: Standard Building (Compliance)_ ' Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft , • ' User Number: 5862 Job Number: Page:4 of 21 ERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF - PROJECT NAME DATE , Andalusia Maintenance Building @ Coral Mountain 1/12/2005 'ONE INFORMATION ' I - Floor Inst. Port i ne iocai enrorcement agency snouia pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines - the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. Plan Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and . documentation for their use have been provided by the applicant. uthorized Signature or Stamp Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:5 of 21 System Name Zone Name Occupancy Type Area (sqft.) LPD (W/sf)1 . LPD (W/sf)1 Ctrl. Credits (W/S2 Tailored proc. Loads (W/sf) LPD (W/sf) 3 BRYANT UNIT ZONE 1 Dining Area 570 *1.100 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST i ne iocai enrorcement agency snouia pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines - the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. Plan Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and . documentation for their use have been provided by the applicant. uthorized Signature or Stamp Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:5 of 21 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME DATE Andalusia Maintenance Building @ Coral Mountain 1/12/2005 OPAQUE SURFACES Type Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments Window 18 0.720 225 0.54 Double Mtl Tinted Default ZONE 1 # Surface Framing Type Type Act. Area U -Fac. Azm. Tilt Solar Gains Y/N Form 3 Reference Location / Comments 1 Roof Wood 570 0.035 0 0 X R-30 Roof R.30.2x12.16 ZONE 1 2 Wall Metal 500 0.036 45 90 X1 I Butler Wall System w/Mtl Sidinq ZONE 1 3 lWall Metal 130 0.189 135 90 X R-11 Metal Stud Wall ZONE 1 4 Wall Metal 402 0.189 225 90 R-11 Metal Stud Wall ZONE 1 5 Door None 40 0.581 225 90 Hollow Metal Door ZONE 1 6 Door None 20 0.581 225 90 X Hollow Metal Door ZONE 1 7 Door None 20 0.581 225 90 1 Hollow Metal Door ZONE 1 8 Wall Metal 130 0.189 315 90 X R-11 Metal Stud Wall ZONE 1 Run Initiation Code: EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:6 of 21 FIFI FENESTRATION SURFACES Site Assembled GlazingCheck box if Building is — 100,000 sqft of CFA and — 10,000 sgft vertical glazing then NFRC Certification is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments Window 18 0.720 225 0.54 Double Mtl Tinted Default ZONE 1 EXTERIOR SHADING ## Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. Hat. Dist. Len. H t. 1 None 0.76 Run Initiation Code: EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:6 of 21 -IGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 1pROJECTNAME DATE +I Andalusia Maintenance Building @Coral Mountain 1/12/2005 (INSTALLED LIGHTING SCHEDULE I AMPR RAI I ARTS IF Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION# watts er Lamp DESCRIPTION # Lam + # t3aflast watts Total Watts CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12/0514:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:7 of 21 + Subtotal from this Page 0 Lighting Schedule on Plans Shows Exterior Lighting Meets Total Portable Lighting (From LTG -1) ❑ Efficacy and Control Requirement of 9130(c) " Less Control Credit Watts (From LTG -3) ❑ Control Requirements of§131(f) Adjusted Actual Watts MANDATORY At1TOMATIC CONTROI R CONTROL LOCATION (Room #) CONTROL IDENTIFICATION NOTE TO FIELD • CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12/0514:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:7 of 21 LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 PROJECT NAME DATE Andalusia Maintenance Building a- Coral Mountain 1 1/12/2005 1 ROOM # DEFAULT AREA OR ZONE ID W/s ft SF TOTAL WATTS B X C TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 0 0 TOTAL 0 0 TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET FA] a o a o o LUMIN. TASK # OF TOTAL TOTAL ROOM # TOTAL AREA OR ZONE ID (SF) Designer needs to provide detailed documentation that the lig/ level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 1 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1 +1C) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 0 0 Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By Energysoft User Number: 5862 Job Number: Page:8 of 21 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME Andalusia Mainter I5YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3 COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER I PIPE INSULATION REQUIRED? I HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATION R -VALUE ance Building @ Cc Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 86 cfm Heat Pum 7.10 HSPF Split DX 10.0 SEER / 9.0 EER BRYANT 3 Ton Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No ral Mountain DATE 1/12) 2005 CODE TABLES: Enter code from table below into columns above. Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:9 of 21 HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD . 0: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/ COOL? HEAT AND COOL SUPPLY RESET? VENTILATION • OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE Use Only INOTES TO FIELD - For Building Department Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:9 of 21 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME DATE Andalusia Maintenance Buildinq @ Coral Mountain 1/12/2005 :HILLER AND TOWER SUMMARY RETURN Efficiency Tons PUMPS Motor Location CFM Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control Blow -Through 1,200 0.00 40.0% 97.0% none FEnergy Factor Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input (Gls.)iency Vol.overy Ext. R -Val. CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Q Output Aux. kW Eff. Output Sensible Efficiency Economizer Type BRYANT 3 Ton Split DX 1 33,000 0.0 7.10 HSPF 34,600 24,22010.0 SEER /9.0 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN F System Name Fan Ty pe Motor Location CFM BHP Motor Eff. Drive I Eff. CFM BHP Motor Eff. Drive Eff. BRYANT 3 Ton Constant Volume Blow -Through 1,200 0.00 40.0% 97.0% none EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 10 of 21 1 LJ. (MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-21 — VAV TERMINAL BOX TERMINAL FAN BASEBOARD Zone Name— System Type Qtv. Min. CFM Ratio Reheat Coil CFM BHP Motor Eff. Drive Eff. Type Output Type DeltaT EXHAUST FAN SUMMARY Room Name Qty. CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM BHP Motor Eff. Drive Eff. i T-1 Run Initiation Time: 01/12/05 14:56:54 Run Code: 1105570614 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 11 of 21 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Andalusia Maintenance Building @ Coral Mountain 1/12/2005 1MECHANICAL VENTILATION A a© o 0 0© a a a o C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:12 of 21 1 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) ZONE 1 570 0.50 285 285 86 200 BRYANT UNIT Total 285 86 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:12 of 21 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Andalusia Maintenance Building I- Coral Mountain DATE 1/12/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Siding, Alum or Steel 2 Polyurethane Foam 3 Air Space 4 Insulation, Mineral Fiber, R-13 5 ASSEMBLY NAME 113utler Wall S stem w/MtI Siding 0.01 7 0.17 6 2.08 ASSEMBLY Floor INSIDE SURFACE AIR FILM 39.15 TYPE (check one) XWall W w W Ceiling / Roof H a FRAMING MATERIAL Metal 0 ? FRAMING % 15 % o Framing /o 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Siding, Alum or Steel 2 Polyurethane Foam 3 Air Space 4 Insulation, Mineral Fiber, R-13 5 Gypsum or Plaster Board 6 0.01 7 0.17 6 2.08 s 0.54 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.000 24.000 0.12 0.850 0.67 12.999 0.25 0.450 0.10 0.01 0.18 0.17 0.03 2.08 0.26 0.54 0.680 39.15 -� ME; KT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 2.44 0.12 0.29 0.67 0.38 0.25 0.07 0.10 0.01 0.18 0.17 0.03 2.08 0.26 0.54 5 t� TOTAL HC 1.1 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [0 X ��] + [� X 1 / Rc 1 - (Fr -/6 / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 13 of 21 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Andalusia Maintenance Buildinq A Coral Mountain DATE 1/12/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 stucco 2 Plywood 3 Insulation, Mineral Fiber, R-11 4 Gypsum or Plaster Board 5 ASSEMBLY NAME R-11 Metal Stud Wall 0.03 7 0.26 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM 13.02 TYPE (check one) Wall 0 0 /Roof H Ceiling y FRAMING MATERIAL Metal 0 Z FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS (in.) 0.875 0.438 3.500 0.500 SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 stucco 2 Plywood 3 Insulation, Mineral Fiber, R-11 4 Gypsum or Plaster Board 5 0.18 6 0.03 7 0.26 8 9 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0.875 0.438 3.500 0.500 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.175 0.543 0.20 11.000 1.24 0.450 0.36 0.18 0.17 0.03 2.08 0.26 0.54 0.680 13.02 RG RT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 8.46 0.20 1.69 1.24 0.29 0.36 0.18 0.17 0.03 2.08 0.26 0.54 12.0 TOTAL HC 2 6 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [0 X 0] + [ I X 1 / Rc 1 - (Fr-/. /100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. I EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paw 14 of 21 1 C ENVELOPE MANDATORY MEASURES ENV -MM ECT NAME Andalusia Maintenance Buildinq (aD- Coral Mountain DATE 1/12/2005 DESCRIPTION Designer Enforcement ❑X § 118(,) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for Insulating material, Title 20, Chapter 4, Article 3. X❑ §118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. 0 §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. - t a § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). 0 § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. IAI §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an Installed R -value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 15 of 21 TAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 (PROJECT NAME DATE Andalusia Maintenance Buildina Ccs. Coral Mountain I 1/12/2005 1. Watts for Illuminance Categories A -D (from column G) 745 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) 0 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) 01+ 1 01+ 1 01 = F 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) 745 watts © © ❑D ❑E ❑F Id TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) FoodService_Dining B 0.00 1,862 0.40 745 BUILDING PAGE TOTAL TOTAL 1 862 745 570 745 SF WATTS EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 16 of 21 v i',N LIGHTING MANDATORY MEASURES LTG -MM OROJECT NAME DATE 1/12/2005 DESCRIPTION Designer Enforcement r §131 (d)l Fore very floor, all Interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. X❑ § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. FXJ§ 119(h) Automatic Control Devices Certified: All automatic control devices specified are v certified, all alternate equipment shall be certified and installed as directed by the manufacturer. X❑ §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. '❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. FX] § 131(a) Individual Room/Area Controls: Each room and area In this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. X❑ § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. 0 § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously ' shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. X❑ § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel G Inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. §130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel Inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 17 of 21 ' � r . 4"'Y' u. MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM oROJECT NAME Andalusia Maintenance Building I- Coral Mountain DATE 1/12/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies X❑ §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. X] §115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. 0 § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditionedfloor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X❑ § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By Energysoft User Number: 5862 Job Number: Page: 18 of 21 MECHANICAL MANDATORY MEASURES NAME Andalusia Maintenance Buildinq (a_ Coral Mountain Part 2 of 2 MECH-MM DATE 1/12/2005 Description Designer Enforcement Ventilation F§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. X] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. ❑ § 121(f)l Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or X] §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(04 Another method approved by the Commission. Service Water Heating Systems X❑ § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X❑ § 113(b)3C Lavatories in re'strooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:19 of 21 C� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 7-7] PROJECT NAME DATE Andalusia Maintenance Building @ Coral Mountain 1/12/2005 YSTEM NAME FLOOR AREA BRYANT UNIT 570 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 33,000 Total Output (Btuh) 33,000 Output (Btuh/sgft) 57.9 Cooling System Output per System 34,600 Total Output (Btuh) 34,600 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 60.7 Total Output (sgft/Ton) 197.7 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 2.11 Airflow (cfm/Ton) 416.2 Outside Air (%) 7.1 Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,324 18,039 1,140 1,276 15,961 0 902 798 0 0 86 3,443 1,086 86 4,189 0 0 902 798 23,286F772,226 21746 BRYANT 3 Ton 21,597 9,500 20,801 Total Adjusted System Output �1 597 9,500 20,801 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 66.2 OF 66.2 OF 82.2 OF O Supply Air Ducts Outside Air 86 cfm 81 6 °F Supply Fan Heating Coil 1200 cfm ROOMS 69.4 OF 70.0 °F 12.0 / 78.5 OF Outside Air 86 cfm 74.7/64.6 °F h Return Air Ducts Y PSYCHROM 77.4 / 65.7 OF 77.4 / 65.7 OF 0 60.7 / 59.5 OF 0 Supply Fan 1200 cfm Cooling Coil h Return Air Ducts 11 Supply Air Ducts 61.4/59 . 8 of 59.7% R.H. ROOMS 74.0 / 64.4 OF EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:20 of 21 1 ROOM LOAD SUMMARY PROJECT NAME Andalusia Maintenance Buildinq (cD- Coral Mountain YSTEM NAME BRYANT UNIT DATE 1/12/2005. FLOOR AREA 570 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE ZONE 1 ZONE 1 1 1,324 18,039 1,140 1,324 18,039 1,140 1,276 15,961 PAGE TOTAL 1,324 18,039 1,140 1,276 15,961 TOTAL 1 1,324 18,039 1,140 1,276 15,961 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 21 of 21