0010-128 (SFD)LICENSED CONTRACTOR DECLARATION
al hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full forced effect.
License # • Lic. Class Exp. Date
73 920
c... ate "f Signature of Contractor
c O/2C
-OWNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business &Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors. -to construct the project (Sec. 7044, • Business & Professionals
Code).
() I am exempt under Section-- , B&P.C. for this reason
Date • Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have arid will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
perfor,,mance of the work for which this permit is issued.
(4 I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Cartier Policy No.
.. MPT
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I.shall not employ any person in any manner so as to become subject to the
workers' compensation laws of Califor a, and agree that if I should become
subject to the workers' compensation/ rov sions of Section 3700 of the Labor
Code, I shall forthwith comply with thio pro isions.
Date:1 a t. ✓ 1 Applicant X 6
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each. person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to,-& shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all gity, and State laws relating to the building
construction, and hereby authorizer representatives of this City to enter upon
the above-mentioned property fortrn pection purposes.
V�b�ignature (Owner/Agent) , t Date
BUILDING PERMIT PERMIT# -
DATEVALUATION LOT 0010•.128 TRACT +
1 !s i:.:1ein • M335.10 i.10 . 9
JOB SITE j
APN
ADDRESS
!.54-446 AVENIDAALVARADO
774-235-021 .,
OWNER
CONTRACTOR / DESIGNER / ENGINEER
WILLIAM `r.rTOx1 ` Ef t /T,TY f
CONTEMPORARY Y Ha '
Po Box 13 •51370
At N?ABS 140:0
L& Q131 1TA. CA VL25:i
LA. QtYI .:A • CA 92253
-
(•760)564.1962 CBLO• 6255
USE OF PERMIT
R
SIM:LE FAMILY MYRIAM
--,»
SF.C1,PER !1.sT DOES NOT f 1CL.UDE 'BLOCK W.Al.LJP0O1.e15.P.A OR APPROACH
Dj•1WAY ..
•
TACT Af; TR.UCT1nk: 1,421.000- Si
hCO
PORCP /RAT1O 36.30 SF
S FR, WOOD f'11N Ct 200.00 LF
OARA0} 510.00 SF
. .i i-MAit1T .ED COSI' OF CONSIRL7iNION
atow.u.o
PKR.M11i 3itl<. , fifilMlitcRY
`,
CO1iSTRUCT10141!E• : 101 WC00-41e,00o $5.94,5x.
?.i., N Ctia.:K F1.. 101 -00 -439-31 g $300,12
MECHANICAL FEE 101.000421-000 $60ODs,
E:),ECTR1C:A1 fe Et{ 101-000-4W-000 $120.44
PL I141331•Z0 FEE 10'.1-000419.000 1 4 ®. 75
STRONC1 MOTION FEE a REVD 101-000.241.000 15.93
O4CAiI:►.fl (1 FEE 101-000-423-000 $21.00
DFlyu��VItt-rt'..OPE`J,'. FM,PACT 11 $1,901T�.0011
7y ♦py�y A n T f
, REC1SEX•"fe.A,i4 101"Q00-411.^'345 ?106.00
F07, D PL' SEr - 101-000-439-310 -$25o.oa
i;fuB-ToT C ol/f T RUQ' rIO» AND .A* CHECK
$3,430.74.
LtZ3 PRE -PAID FEE
44250:00
. TOTAL '.V.03.N: 1:'FEZ'S"DTUE NOW
S".34130.74
• - .
I1111VIIIIII
IE
66
VIII 1111
I
RECEIPT
DATE ,
BY
DATE Ff�ALED
/0/
INSPECTOR
t,�'/1I01C.0
t4, ..
/
INSPECTION RECORD
OPERATION
DATE i ( INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs//
'
Underground Ducts
Ducts
Forms & Footings•
().°�
a' (O'
Slab Grade
1
Retum Air
Steel
��
Combustion Air
Roof Deck
- i5��1�`�
1 - i- i
5 g of
rExhaust
oy r
Fans
F.A.U.
O.K. to Wrap
Framing
Z
Compressor
.
Insulation
3 /2 0 (
.57"
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath r
3 l 1
Se` '
Final
Final
0
tS
POOLS - SPAS
BLOCKWALI, AP?ROYALS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Linesc�
Heater Final
Water Piping
��•( 5'0
6.Y
'"
Plumbing Final
Equipment Enclosure
Plumbing Top Out
Shower Pans
O.K for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
'(- t 5_ ao
Encapsulation
Gas Piping
Jf/F/Q (
\ G
.ar
Final
Gas Test
Appliances
COMMENTS:
Final
Utility Notice (Gas)
` ELECTRICAL APPROVALS
„5,'
Temp. Power Pole
CZ - /3- ad
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
��
Utility Notice (Perm)
la ®l
6711111111131111II _______n
9
, E 4 4C4g4trai
�Y-(itis Ave AGI/ ,t d -
R"Tft�i4 P.O. BOX 1504 APPLICION ONL'
Building \ '4141 �,(, AL AKIVDc) 78-495 CALLE TAMPICO
Address LA QUINTA, CALIFORNIA 92253
Owner `i.`t
Mailing 7
Address k 7 \ 3�
City
Zi
Tel 4 ro,U1
Contractor
Address?
BUILDING: TYPE -CONST.'^' `/ t I OCC. GRP.
A.P. Number
P
Legal Description
Project Description
7
IL.
City ( ,
—\ QJ,F'
Zip )01 S3
Tel. (
State Lic. aq
& Classif.\3 1 (,
City O � t�
Lic. # vat
g,., (-1.1L
IA (-
IA I) 6 V.
Sq. Ft. /
Size
No.
Stories
No. Dw. 1
Units
NewA Add 0
Alter 0
Repair 0
Demolition 0
Address,
�J1.4 O
Tel.{ C�
j?(),
MAT -E-32 ( S -I )
City ( Zip
►-� � t j' `baa s3
State
Lic. #
s•;
LIC LASED CONTRACTOR'S DECLARATION
I hereby affirm that I am Ii enspd under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the B` ne s and Professions Code, and my license is in full force and
effect. J'
SIGNATURE % DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars (5500).
t-: I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I I I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
11 I am exempt under Sec B & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No Company
(1 Copy is filed with the city. 0 Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (5100) valuation
or less.)
I certify that in the performance of thF workjoiwhic)t this permit is issued, I shall not
employ,any person in any manner so as to beco%mubject to the Workers' Compensation
Laws ot California: f
Date / Owner
NOTICE TO APPLICANT: lf, after making this Certifies of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
1 hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration it work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives .of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
A's S- ( dvtA T Q_
Estimated Valuation
PERMIT
AMOUNT '
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
ZONE: BY.
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
•
t
FINAL DATE INSPECTOR
Issued by' Date
Validated by:
Validation: '
Permit
1
WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION
•
1
IIIIIIIIIITIIIIIIIIIIII 68
T'Certificate of Occupancy
City of La Quinta
Building and Safety Department
IE
This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code,
certifying that, at the time of issuance, this structure was in compliance with the various ordinances
of the City regulating building construction or use. For the following:
BUILDING ADDRESS: 54-445 AVENIDA ALVARADO
Use Classification: SFD
Bldg. Permit No.: 0010-128
Occupancy Group: R 3 Type of Construction: VN Land Use Zone: RC
Owner of Building: WILLIAM THOMAS BUFFIN
Building Official
Address: P.O. BOX 13
City: LA QUINTA, CA 92253
By: STEVE TRAXEL
Date: 05-25-01
POST IN A CONSPICUOUS PLACE
Notice:
Document Cannot Be Duplicated
Date 10/16/00
No. 21101
Desert Sands Unified School District
47-950 Dune Palms Road
La Quinta, CA 92253
760-771-8515
CERTIFICATE OF COMPLIANCE
Owner NameWilliam Thomas Buffin
11111111IIIIIIIIIIIIIIIII 69
IE
APN # 774-235-021
Jurisdiction La Quinta
No. 54-445
City La Quinta
Tract #
Street Avenida Alvarado
zip 92253
Lot # 9
Type of Development Single Family Residence
Comments
Permit #0010-128
Log #
Study Area
Square Footage 1421
No. of Units 1
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It
has been determined the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Government Code 53080 in the amount of
2.05 X 1,421 or $ 2,913.05 the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued
Telephone 760-564-1962
Fees Paid By CC / Valley Independent Bank / Robert Kellogg
Name on the check
By Dr. Doris Wilson
Superintendent
Fee collected /exgfnpted by
Signature
Annette Barlow
Payment Received $2,913.05
Check No. 227466
NOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified
above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
collect them on the District('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
illirSev.14, 2000 10:5SAM POWER BROKERS
RECORDING REQUESTED BY:
OLD REPUBLIC TITLr►.COMPACOMPANY
10314KC 506899-13
No.5555 P. 1/1
IIIIIIIIIIIIIIIIIIIIIIIII 70
IE
SPACE ABOVE THIS LINE fOR RECORDER'S•.SE
APR; 774. 3S-021- jj�� 4.c)
S �i' L44S Ave.. Aiva.r&
GRANT DEED
The undersigned.grantorta) declare(s);
Documentary transfer tax is •
(XXX) Computed on full value of property conveyed, or
( ) Computed on full value leas liens and encumbrances remaining at time of sale;
( .) Unincorporated area: ( ) City of and
FOR A VALUABLE CONSIDERATION. receipt of which -is hereby acknowledged,
JOSaEH 3M O and MARY SARDC, TRUSTEES OR SUCCESSOR TRUSTEES OF THE SARDO LZVINQ TRUST
CREATED BY REVOCABLE TRUST AGREEMENT DATED 7/28/95
hereby _GRANT (S) to
WILLIAM. THOMAS BUM, AN UNMARRIED MAN
the real property in the City of LA QUINTA. County of Riverside, State of California,
described asp
Lot 9, Block 264, Unit >vo. 24„ Tract Santa Carmelite at Vale La Quints, as per map
recorded in Book 19. Page(s) 44-45 inclusive of maps, in the office of the county
.Recorder of Bald County.
Dated August 25. 2000
State of Cal'LPornia
County of <'f}N\.,\ - } S.S.
On w T---
before me. �e tAV, - N
, personally appeared
(or pso»_d Co tis Oh
the beefs of satisfsctory evidence) co De
the person(s)-whose neme(s) hr/are subscribed
Co she within instrument and acknowledged to
me. shat., Iy/aJe/they exucutedthe same in
h4e4har/their authorized capacity(ies), and
that by h-,4r4or/their signatures) on the
instrument the person(s), or the entity upon
UllniarCJL w LLui
the instrument.
wrTNBSS hand and offic
Signature
MAIL TAX STAT MENTS TO:
x
fril. TRuSTEB
(This area for official notarial seal)
ENERGV
TITLE 24 COMPLIANCE REPORTS +
ENERGY ANALYSIS
FOR
54425 Ave. Alvarado
LaQuinta CA
NOVEMBER 09 1993
IIIIIIIIVIIIIIIVIIIIIII 47
IE
69116 Club Road ® Cathedral City, CA 92234 ■ (619) 328-5898
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
......... - -----------Date ........ 11/09/93
Project Title Stemmer
Project Address........ 54425 Ave. Alvarado ---------------------
LaQuinta CA ;
Documentation Author... Barbara Bartlett ; Building Permit # ;
Company ................ DESERT ENERGY CONSULTING
Telephone .............. (619)328-5898 ; Plan Check / Date ;
Compliance Method...... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date ;
Climate Zone........... 15 -------------------=-
--------------------------------------------------------------------
MICROPAS4 v4.01 File-STEMMER Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS93008C
-------------------------------------------------------------------------------
GENERAL INFORMATION
Conditioned Floor Area..... 1350 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units'... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade (Package D)
BUILDING SHELL INSULATION
Component
Insulation Assembly
Type
-------------
----------
R -value
U -Value
--------
Location/Comments
Wall
R-13
0.088
----------------------------------------
Entry.Living, Din.Kit.MBed,
MBed.Bath
Bedrms.Living, To Garage
Roof
R-38
0.029
Roof
S1abEdge
R-0
0.900
To Outside
S1abEdge
R-0
0.720
To Outside
S1abEdge
R-0
0.550
To Garage
Door
R-0
0.330
Entry, Garage Door
FENESTRATION
------------
Over-
Area
U- # of
Interior Exterior
hang/
Framing
Orientation
-------------------
(sf.)
-----
Value Panes
----- -----
Shading Shading
------------------------
Fins
Type
Window Front
(E)
65.0
0.880 2
Blinds.Lt None
------
Yes
--------
Metal
Door Left
(S)
80.0
0.880 2
Blinds.Lt None
Yes
Metal
Window Left
(S)
9.0
0.880 2
Blinds.Lt None
Yes
Metal
Window Right
(N)
61.5
0.880 2
Bli.nds.Lt None
Yes
Metal
THERMAL MASS
------------
Area Thickness
Type Exposed (sf) (in)
------------ -------------- ---------------
S1abOnGrade Yes 641 3.5
S1abOnGrade No 709 3.5
Location/Comments
------------------------
Kit.Din.Baths.Entry
Typical
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... Stemmer Date........ 11/09/93
' MICROPAS4 v4.01 File-STEMMER Wth-CTZ15S92 Program -FORM CF -1R '
User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS93008C ;
-------------------------------------------------------------------------------
HVAC SYSTEMS
WATER HEATING SYSTEMS
---------------------
Number
in
Tank Type Heater Type Distribution Type System
------------ ----------- ------------------- ------
Storage HeatPump Standard 1
SPECIAL FEATURES/REMARKS
------------------------
Tank External
Energy Size Insulation
Factor (gal) R -value
-------- ------ ----------
2.8 EF 40 R- 16
Minimum
Duct
Duct
Thermostat
Equipment Type
---------------
Efficiency
------------
Location
-------------
R -value
Type
HPSplit
6.8 HSPF
Attic
-------
R-4.2
------------
Setback
HPSplit
10.00 SEER
Attic
R-4.2
Setback
WATER HEATING SYSTEMS
---------------------
Number
in
Tank Type Heater Type Distribution Type System
------------ ----------- ------------------- ------
Storage HeatPump Standard 1
SPECIAL FEATURES/REMARKS
------------------------
Tank External
Energy Size Insulation
Factor (gal) R -value
-------- ------ ----------
2.8 EF 40 R- 16
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
-------------------------------------------------------------------------------
Project Title.......... Stemmer Date........ 11/09/93
--------------------------------------------
MICROPAS4 v4.01 File-STEMMER Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS93008C
-------------------------------------------------------------=-----------------
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name....
Joe Stemmer
Name....
Barbara Bartlett
Company.
n/a
Company.
DESERT ENERGY CONSULTING
Address.
42995 Latisha Lane
Address.
'69116 Club Road
Palm Desert CA 92211
Cathedral City,
CA 92234
Phone...
(61 ) 45-9571
Phone...
(619)328-5898
License.
n/
Signed..
Signed..
/
(date)
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... Stemmer- Date........ 11/09/93
Project Address........ 54425 Ave. Alvarado ---------------------
LaQuinta CA
Documentation Author... Barbara Bartlett Building Permit # ;
Company ................ DESERT ENERGY CONSULTING
Telephone .............. (619)328-5898 ; Plan Check / Date
Compliance Method...... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date
Climate Zone......:..... 15 ---------------------
------------------------------------------------------------
MICROPAS4 v4.01 File-STEMMER Wth-CTZ15S92 Program -FORM C -2R ;
User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS93008C
-------------------------------------------------------------------------------
----------------------------
----------------------------
MICROPAS4 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_---------------------------------
Design
Design
----------
Margin =
-
- Space Heating..........
2.76
2.54
----------
0.22 =
- Space Cooling..........
32.37
33.73
-1.36 =
- Water Heating..........
15.22
8.21
7.01 =
= Total
50.35
44.48
5.87 =
_ *** Building complies
with Computer
Performance
GENERAL INFORMATION
-------------------
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area.............
Ground Floor Area..........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Ceiling Height.:...
1350 sf
Single Family Detached
New
Front Facing 90 deg (E)
1
1
ReducedYear
Slab On Grade
1
12782 cf
1350 sf
1350 sf
1350 sf
16 % of FA
9.5 ft
(Package D)
COMPUTER
METHOD SUMMARY
Area
Page
2 C -2R
Project
Title........
Stemmer
-----------------
Date........
11/09/93
MICROPAS4
-------------------------------------------------------------
v4.01
File-STEMMER
Wth-CTZ15S92
Program -FORM
C -2R
-------------------------------------------------------------------------------
User#-MP1442
User
-DESERT ENERGY CONSULTING
Run-JS93008C
2
Metal
3
Window
BUILDING ZONE INFORMATION
-------------------------
2
Metal
4
Floor
80.0
# of
Metal
Vent Special
Window
Area
Volume
Dwell Cond-
Thermostat
Height Vent Area
Zone Type
--------------
(sf)
---------
---------
(cf) Units itioned
------------
Type
------------
(ft) (sf)
HOUSE
------ ---------
Residence
1350
12782 1.00 Yes
Setback
2.0 n/a
OPAQUE SURFACES
Area
U-
---------------
Insul Act Solar
Form 3
Location/
Surface
--------------
(sf)
------
value
-----
R-val Azm Tilt Gains
-----
Reference
Comments
HOUSE
--- ---- -----
------------
----------------
1 Wall
108
0.088
R-13 90 90 Yes
None
Entry.Living
2 Wall
191
0.088
R-13 180 90 Yes
None
Din.Kit.MBed
3 Wall
242
0.088
R-13 270 90 Yes
None
MBed.Bath
4 Wall
386
0.088
R-13 0 90 Yes
None
Bedrms.Living
5 Wall
232
0.088
R-13 180 90 No
None
To Garage
6 Roof
1350
0.029
R-38 90 20 Yes
None
Roof
10 Door
20
0.330
R-0 90 90•Yes
None
Entry
11 Door
20
0.330
R-0 180 90 No
None
Garage Door
PERIMETER LOSSES
Length
----------------
F2 Insul
Surface
------------
(ft)
------
Factor R-val Location/Comments
HOUSE
--------------- ----------------------
7 S1abEdge
50
0.900 R-0 To
Outside
8 S1abEdge
76
0.720 R-0 To
Outside
9 S1abEdge
21
0.550 R-0 To
Garage
FENESTRATION SURFACES
---------------------
SC SC Interior
Open U- Act Glass Int Shade
Type value Azm Tilt Only Shade Description
------ ----- --- ---- ----- ----- ------------
Slider 0.88 90 90 0.77 0.49 Blinds.Lt
Slider 0.88 90 90 0.77 0.49 Blinds.Lt
Fixed 0.88 90 90 0.77 0.49 Blinds.Lt
Slider 0.88 180 90 0.77 0.49 Blinds.Lt
Slider 0.88 180 90 0.77 0.49 Blinds.Lt
Slider 0.88 0 90 0.77 0.49 Blinds.Lt
Area
# of
Frame
Surface
-----------
(sf)
-----
Panes
-----
Type
--------
HOUSE
1
Window
30.0
2
Metal
2
Window
30.0
2
Metal
3
Window
5.0
2
Metal
4
Door
80.0
2
Metal
5
Window
9.0
2
Metal
6
Window
61.5
2
Metal
SC SC Interior
Open U- Act Glass Int Shade
Type value Azm Tilt Only Shade Description
------ ----- --- ---- ----- ----- ------------
Slider 0.88 90 90 0.77 0.49 Blinds.Lt
Slider 0.88 90 90 0.77 0.49 Blinds.Lt
Fixed 0.88 90 90 0.77 0.49 Blinds.Lt
Slider 0.88 180 90 0.77 0.49 Blinds.Lt
Slider 0.88 180 90 0.77 0.49 Blinds.Lt
Slider 0.88 0 90 0.77 0.49 Blinds.Lt
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... Stemmer Date........ 11/09/93
-----------------------------------------------------
MICROPAS4 v4.01 File-STEMMER Wth-CTZ15S92 Program -FORM C -2R
User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS93008C
-------------------------------------------------------------------------------
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left
Mass Type
---------------
HOUSE
1 S1abOnGrade
2 S1abOnGrade
Left Rght
Fin--- ---Right Fin--
Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
n/a
1.5
Area
n/a
Surface
-----------
(sf)
-----
Hght
-----
HOUSE
n/a
n/a
1
Window
30.0
5.0
2
Window
30.0
5.0
3
Window
5.0
5.0
4
Door
80.0
5.5
5
Window
9.0
5.5
6
Window
61.5
3.0
Mass Type
---------------
HOUSE
1 S1abOnGrade
2 S1abOnGrade
Left Rght
Fin--- ---Right Fin--
Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
n/a
1.5
2.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
1.5
2.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
1.5
2.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
2.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
2.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
2.0
1.0.
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
THERMAL MASS
------------
Area Thick Heat Conduct- Surface
(sf) (in) Cap ivity R -value Location/Comments
------ ----- ----- -------- -------- --------------------------
641 3.5 28.0 0.98 R-0.0 Kit.Din.Baths.Entry
709 3.5 28.0 0.98 R-2.0 Typical
System Type
----------------
HOUSE
HPSplit
HPSplit
Tank Type Heater Type
------------ -----------
1 Storage HeatPump
HVAC SYSTEMS
------------
Minimum Duct Duct Duct
Efficiency Location R -value Efficiency
------------ ------------- ------- ----------
6.8 HSPF Attic
10.00 SEER Attic
WATER HEATING SYSTEMS
---------------------
Number
in
Distribution Type System
------------------- ------
Standard 1
SPECIAL FEATURES/REMARKS
------------------------
R-4.2 0.830
R-4.2 0.810
Tank
External
Energy Size
Insulation
Factor (gal)
-------- ------
R -value
----------
2.8 40
R-16
HVAC SIZING Page 1 HVAC
Project Title.......... Stemmer Date....:... 11/09/93
Project Address........ 54425 Ave. Alvarado ---------------------
LaQuinta CA
Documentation Author... Barbara Bartlett Building Permit #
Company ................ DESERT ENERGY CONSULTING
Telephone .............. (619)328-5898. ; Plan Check / Date ;
Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone........... 15 ---------------------
MICROPAS4 v4.01 File-STEMMER Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS93008C
------------------------------------------------------------------------------=
GENERAL INFORMATION
Floor Area ................. 1350 sf
Volume... ................ 12782 cf-
Front Orientation.......... Front Facing 90 deg (E)
Sizing Location...... INDIO
Latitude ................... 33.7 degrees
Winter Outside Design...... 29 F
Winter Inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range ............... 30 F
Interior Shading Used...... No
Exterior Shading Used...... No
Overhang Shading Used...... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Heating
Cooling
Description
--------------------------------------------
(Btuh)
(Btuh)
Opaque Conduction and Solar......
10888
-----------
5596
Glazing Conduction ...............
7775
6448
Glazing Solar ....................
n/a
5709
Infiltration .....................
7537
4467
Internal Gain .....................
n/a
2100
Ducts ............................
2620
2432
Sensible Load ....................
28821
26752
Latent Load ......................
n/a
5350
Minimum Total Load
-----------
28821
-----------
32103
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
Mandatory Measures Checklist: Residential
MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance
approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements
listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features
noted shall be considered by all parties as binding minimum component performance specifications for the
mandatory measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION
Building Envelope Measures
* §150(a): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
* §I50(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls).
* §150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors.
§150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118: Insulation specified or installed meets California Energy Commission quality standards.
Indicate type and form.
§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
b. Manufactured fenestration products have label with certified U -value, and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§I50(g): 'Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): SpecW infiltration barrier installed to comply with §151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(i): Setback thermostat on all applicable heating systems.
§1500): Pipe and Tank Insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater).
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating sections of hot water system.
4. Cooling system piping below 55°F insulated.
5. Piping insulated between heating source and indirect hot water tank.
* §150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
manually operated dampers..
§114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,
no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36' pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no
continuously buring pilot light. (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.)
Lighting Measures
§150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water.cosets; and
recessed ceiling fixtures IC (insulation cover) approved.
Revised January 1992
DESIGNER I ENFORCEMENT