SFD (04-8349)60375 Living Stone Dr
04-8349
(760).777-7012
OFTt�9 78-495 CALLE TAMPICO
6�+-'47z-j 011
LA QUINTA, CALIFORNIA 92253 , INSPECTI
T -S..( i6 77 153
BUILDING PERMIT APR
0 4 2005
:CIP'IYoNaN,OF LA'QuINTa
Application Number. .
. . . .0 04---0-00083.4.9,;%
3/29/05
Property Address
60375 LIVING STONE DR
APN:
764-270-999-46 -300233-
Application description
. . . DWELLING - SINGLE FAMILY
DETACHED
Property Zoning . .
. . . MEDIUM HIGH DENSITY RES
Application valuation
148309
Owner
Contractor
------------------------
------------------
SHEA LA QUINTA
SHEA HOMES, INC.
C/O JEFF MCQUEEN
81260 AVENUE 62
8800 N GAINEY CENTER
350 LA QUINTA
CA 92253
SCOTTSDALE
AZ 85258 (760) 777-6005
WCC: NTL UNION'INS
WC: 6436568
08/01'/05
CSLB: 672285
06/30/05
CCC: B.
--------------------------
Structure Information -----------------------=-
Construction Type . .
. ... TYPE V - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/CONG <=10
Flood Zone . . . . .
. . . NON -AO FLOOD ZONE
Other struct info
CODE EDITION
2001 CBC
FIRE SPRINKLERS
NO
GARAGE SQ FTG
488.'00
PATIO SQ FTG
1.77 .-,00
NUMBER-OF"UNITS '�
" ,} 1.00
1ST FLOOR SQUARE FOOTAGE
1688.00
Permit . . . . . .
BUILDING PERMIT...,
Additional desc
s
Permit Fee811.00
Plan Check Fee
131.79
Issue Date . . . .
Valuation
. . 148309
Qty Unit Charge
Per
Extension
BASE FEE
639.50
4'9.00 3.5000
THOU BLDG 100,001-500,000
171.50
Permit . . . .
MECHANICAL
Additional desc
Permit Fee
64.00 Plan Check Fee
4.00
Issue Date
Valuation
. . 0
Qty Unit Charge
Per.
Extension
BASE • FEE `
15.00
2.00 9."0000
EA-. ,' MECH ^FURNACE <=100K
- 18. OD
2-.00 9.0.0,0.0
EAu%'' MECH-B/' <='3HP/100K• BTU
18.00
1.00 6.5000
EA MECH VENT FAN
6.50
k-
P.O. Box 1504 • VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: Date: �• /•OSS
Applicant: Architect or Engineer:
Applicant's Mailing Address: rchi or Engj7�r's • re � /y%2N2
04
ic. No.: 2 0gL01
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my Licenses, in full force and effect. & 722Z S
/�(_icens�efClass_ �•� C L e No.
Date / D O ontractor Jul
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensate insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
d My workems' c pensation rance carrier—MOV
n pi rn r
amer olicy Number
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby auth�ignature
esentatives of this county to e r upon the abov -menti a perty for inspect* n purposes.
Date D 6S (Applicant or Agent):
t �
0
Page
2
Application Number
04-00008349 Date
3/29/05
Qty" Unit Charge Per
Extension.
1.00.6.5000 EA
MECH EXHAUST HOOD
6.50
Permit . . . ELEC-NEW
RESIDENTIAL
Additional.desc
Permit Fee
83.84 Plan Check Fee
5.24
Issue Date
Valuation . . . .
0
Qty Unit Charge, Per
Extension
BASE FEE
15.0.0
1688.00 .0350
ELEC.NEW RES - 1 -OR 2 FAMILY
59.08
488.00 .0200
------------------------------
ELEC GARAGE OR NON-RESIDENTIAL
9.76
Permit PLUMBING
--------------------------------------------
.Additional desc
Permit Fee*128.25
Plan Check Fee
8.02
Issue Date
Valuation . . . .
0
Qty Unit Charge Per
'Extension
BASE FEE
15.00
10.00 6.0000•EA
PLB FIXTURE
60.00
1.00 15.0000 EA
PLB BUILDING SEWER
15.00
1.00 7.5000 EA
PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA
PLB WATER INST/ALT/REP.
3.00
1.00 9.0000 EA
PLB LAWN SPRINKLER SYSTEM
.9.00
.5.00 .7500 EA
PLB GAS PIPE >=5
3.75
1.00 15.0000 EA
PLB GAS METER
,15.00
Permit . . . . . . GRADING
PERMIT
Additional desc
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Qty -Unit Charge Per
Extension
BASE FEE
15.00
Special Notes and Comments
.SFD - LOT 46, 1688 SF PLAN
4520A/BOX
BAY @.MBR=26 SF. PERMIT DOES
NOT
INCLUDE -BLOCK WALLS, POOL,
SPA OR
DRIVEWAY APPROACH. 75% REDUCTION
TO PLAN
CHECK FEE DUE TO MULTIPLE
ISSUANCE -OF
SAME PLAN TYPE
-----------------------------------------------
Other Fees �.1.
-----------------------
ART IN PUBLIC PLACES -RES
.00
Page 3
Application Number
. . . . .
04-00008349 Date
3/29/05
------------------------------------------------------------------------------
Other Fees . . .
. .
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
13.18
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5..00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
14.83
DIF STREET MAINT FAC -RES
15.•00
DIF TRANSPORTATION - RES.
1098.00
Fee summary
Charged
Paid -Credited
'Due ;
Permit Fee Total
1102.09.
.00 .00
1102.09
Plan Check Total
149.05
.00 .00
149.05
Other Fee Total
2433.01
.00 .00
.2433.01
Grand Total
.3684.15
.00 .00
3684.15
j A
.
1.
JCM: Inspections
7J_ 39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS, Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
COMPRESSION STRENGTH TEST RESULTS
Client: Shea La Quinta, LLC
Date: 6/14105
Project: Trilogy @ La Quinta - Shea Homes
Project No: 02-1109
81-260 Avenue 62
La Quinta, CA 9227.4
Set ID Structure
Age of Test
Compression Strength
JCM ID Location
Date Cast Cylinder. ID (days)
(psi)
Set A Phase 9C - Lot #3046 Slab on Grade
5-12-05
Concrete
273-511
Kitchen
Required psi: 4000
66 7
3310
67 28.
4620
ff
V) Q(9ST6,J G C 9,
68 28
4670
Page 1 of 1
JCM Inspections
39725 Garand Lane Suite F
L] J Palm Desert, CA 92211
-INSPECTIONS Phone: 760-345-5.554�.- Fax: 760-772-3895 INSPECTIONS
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below.
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:•
81-260 Avenue 62 La Quinta, CA
[?]IBC
E] Title 24
Others
Client: Sub -Contractor: A
Shea La Quinta, LLC DCCCCI
General Contractor: Architect: Structural Engineer:
Shea Homes Bassenian Lagoni Borm'& Assoc, Inc/Suncoast Post Tension LP
-----------
Slump (inches): S, 00 Supplier: Superior
Time Sampled: RI "!S-0 0 V" Mix Design:. D83625P
Time in Mixer ixer (min.): (e)o Specified Strength (PSI): 4000
Water Added @ Jobsite (gals.): /0 Addmixture: PCIZZ 322N
Concrete Temperature (F): Truck #: (=_3z:_Ticket #: -1 q 11
Ambient Air Temperature (F): a1 Field ID Marking: Set A - 4 cylinders
We i ather:
Unresolved Items:
1201one
See Below
Location of Sample: V1
E] No Samples Taken
Description of Work Inspected: Phase CN, Lot# 3()q(oProduct- Plan
0 32GI o"
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional
rebar placed as per these details and as noted on -S W1
Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
_0
1) The placement of -concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days(2)and one for holding purposes.
Sl 13-oS
.1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx 3 Verified correct mix design.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications -applicable building laws. Final report issued at project completion.
-inspector: A C. Millin ICC ffiCation No: '1 -80
Contractor's Representative:
Copy 1 JCIVI Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of